Search NASA⌕ Search

SEARCH · Search NASA

Results for “RADIATION MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Non-thyroid cancer incidence in Belarusian residents exposed to Chernobyl fallout in childhood and adolescence: Standardized Incidence Ratio analysis, 1997–2011

Background: While an increased risk of thyroid cancer from post-Chernobyl exposure to Iodine-131 (I-131) in children and adolescents has been well-documented, risks of other cancers or leukemia as a result of residence in radioactively contaminated areas remain uncertain. Methods: We studied non-thyroid cancer incidence in a cohort of about 12,000 individuals from Belarus exposed under age of 18 years to Chernobyl fallout (median age at the time of Chernobyl accident of 7.9 years). During 15 years of follow-up from1997 through 2011, 54 incident cancers excluding thyroid were identified in the study cohort with 142,968 person-years at risk. We performed Standardized Incidence Ratio (SIR) analysis of all solid cancers excluding thyroid (n=42), of leukemia (n=6) and of lymphoma (n=6). Results: We found no significant increase in the incidence of non-thyroid solid cancer (SIR=0.83, 95% Confidence Interval [CI]: 0.61; 1.11), lymphoma (SIR=0.66, 95% CI: 0.26; 1.33) or leukemia (SIR=1.78, 95% CI: 0.71; 3.61) in the study cohort as compared with the sex-, age- and calendar-time-specific national rates. These findings may in part reflect the relatively young age of study subjects (median attained age of 33.4 years), and long latency for some radiation-related solid cancers. Conclusions: We found no evidence of statistically significant increases in solid cancer, lymphoma and leukemia incidence 25 years after childhood exposure in the study cohort; however, it is important to continue follow-up non-thyroid cancers in individuals exposed to low-level radiation at radiosensitive ages. - Highlights: • We monitor cancers in a Belarusian cohort of exposed as children due to Chernobyl. • No increase in solid cancer rates was found as compared to the national rates. • An elevation of leukemia rates was detected, although statistically insignificant. • Results are consistent with those in a cohort of exposed as children in Ukraine. • Further monitoring of cancer situation in this cohort is warranted.

54 ENVIRONMENTAL SCIENCES↗

Four-Dimensional Patient Dose Reconstruction for Scanned Ion Beam Therapy of Moving Liver Tumors

Purpose: Estimation of the actual delivered 4-dimensional (4D) dose in treatments of patients with mobile hepatocellular cancer with scanned carbon ion beam therapy. Methods and Materials: Six patients were treated with 4 fractions to a total relative biological effectiveness (RBE)–weighted dose of 40 Gy (RBE) using a single field. Respiratory motion was addressed by dedicated margins and abdominal compression (5 patients) or gating (1 patient). 4D treatment dose reconstructions based on the treatment records and the measured motion monitoring data were performed for the single-fraction dose and a total of 17 fractions. To assess the impact of uncertainties in the temporal correlation between motion trajectory and beam delivery sequence, 3 dose distributions for varying temporal correlation were calculated per fraction. For 3 patients, the total treatment dose was formed from the fractional distributions using all possible combinations. Clinical target volume (CTV) coverage was analyzed using the volumes receiving at least 95% (V{sub 95}) and 107% (V{sub 107}) of the planned doses. Results: 4D dose reconstruction based on daily measured data is possible in a clinical setting. V{sub 95} and V{sub 107} values for the single fractions ranged between 72% and 100%, and 0% and 32%, respectively. The estimated total treatment dose to the CTV exhibited improved and more robust dose coverage (mean V{sub 95} > 87%, SD < 3%) and overdose (mean V{sub 107} < 4%, SD < 3%) with respect to the single-fraction dose for all analyzed patients. Conclusions: A considerable impact of interplay effects on the single-fraction CTV dose was found for most of the analyzed patients. However, due to the fractionated treatment, dose heterogeneities were substantially reduced for the total treatment dose. 4D treatment dose reconstruction for scanned ion beam therapy is technically feasible and may evolve into a valuable tool for dose assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterisation of amorphous silica in air-oxidised Ti 3 SiC 2 at 500-1000 °C using secondary-ion mass spectrometry, nuclear magnetic resonance and transmission electron microscopy

In this paper we have described the use of secondary-ion mass spectrometry (SIMS), solid state {sup 29}Si magic-angle-spinning (MAS) nuclear magnetic resonance (NMR) and transmission electron microscopy (TEM) to detect the existence of amorphous silica in Ti{sub 3}SiC{sub 2} oxidised at 500-1000 C. The formation of amorphous SiO{sub 2} and growth of crystalline TiO{sub 2} with temperature was monitored using dynamic SIMS and synchrotron radiation diffraction. A duplex structure with an outer TiO{sub 2}-rich layer and an inner mixed layer of SiO{sub 2} and TiO{sub 2} was observed. Results of NMR and TEM verified for the first time the direct evidence of amorphous silica formation during the oxidation of Ti{sub 3}SiC{sub 2} at the temperature range 500-1000 C.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement and Evaluation of Inhomogeneity Corrections and Monitor Unit Verification for Treatment Planning

Heterogeneous lung and bone phantoms have been constructed for the purpose of testing monitor unit calculations at or near interfaces for different planning systems. Data have been acquired for 2 linear accelerators: a Varian 2300cd (6 and 25 MV) and an Elekta Synergy (6, 10, and 18 MV). We have reviewed Pinnacle and the correction-based, pre-AAA version of Eclipse planning systems with the intent of exploring the limits of these systems with energy and field size. Data were acquired from 2 x 2 to 10 x 10 cm{sup 2} field sizes over the available range of energies. Our measurements confirm that Pinnacle predicts doses mostly to within {+-} 5%, even near lung-tissue interfaces over the full range of energies and field sizes tested. The Eclipse-modified Batho and equivalent TMR algorithms overpredicted doses by 10% or more in the lung and near the lung-tissue interfaces if the field size was less than 10 x 10 cm{sup 2} when the energy was 18 MV or higher. At lower energies, the field size had to be at least 6 x 6 cm{sup 2} for calculated doses to be within 10% of measurement. For bone-tissue interfaces, doses were generally underestimated by 5% to 10% or more by all calculation methods over the range of field sizes and energies reviewed. A second goal of this study was to review methods for hand-checking monitor units when heterogeneities are included. We evaluated the range of applicability of 2, one-dimensional (1D) inhomogeneity correction factors: the effective attenuation method and the TMR ratio method. The effective attenuation method for monitor unit checking was within {+-} 5% to as small as 6 x 6 cm{sup 2} fields for 6 to 10 MV, useable for 4 x 4 cm{sup 2} fields (within 7%) for 6 MV and close to {+-} 5% for 10 x 10 cm{sup 2} fields in the 18- to 25-MV range. The TMR ratio method was not as good, being within about {+-} 5% to 7% of measurements only for 6 x 6 to 10 x 10 cm{sup 2} fields at 6 MV and 10 x 10 cm{sup 2} fields at the higher energies. Both simple 1D correction methods performed almost as well as Pinnacle for the bone-soft tissue cases. We recommend that if direct measurement of dose for heterogeneous treatment plans is not practiced, then one of these simple cross checks be performed to assure patient safety.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Extreme ultraviolet spectroscopy diagnostics of low-temperature plasmas based on a sliced multilayer grating and glass capillary optics

New extreme ultraviolet (EUV) spectroscopic diagnostics of relatively low-temperature plasmas based on the application of an EUV spectrometer and fast EUV diodes combined with glass capillary optics is described. An advanced high resolution dispersive element sliced multilayer grating was used in the compact EUV spectrometer. For monitoring of the time history of radiation, filtered fast EUV diodes were used in the same spectral region (>13 nm) as the EUV spectrometer. The radiation from the plasma was captured by using a single inexpensive glass capillary that was transported onto the spectrometer entrance slit and EUV diode. The use of glass capillary optics allowed placement of the spectrometer and diodes behind the thick radiation shield outside the direction of a possible hard x-ray radiation beam and debris from the plasma source. The results of the testing and application of this diagnostic for a compact laser plasma source are presented. Examples of modeling with parameters of plasmas are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Natural Radionuclide Activity Concentrations In Spas Of Argentina

Geothermal waters have been used on a large scale for bathing, drinking and medical purposes. These waters can contain natural radionuclides that may increase the exposure to people. In this work the most important natural radionuclide activity concentrations in different thermal spas of Argentina were measured to characterize waters and to evaluate the exposure of workers and members of the public.

54 ENVIRONMENTAL SCIENCES↗

Sputtering yields of Ru, Mo, and Si under low energy Ar{sup +} bombardment

Ion sputtering yields for Ru, Mo, and Si under Ar{sup +} ion bombardment in the near-threshold energy range have been studied using an in situ weight-loss method with a Kaufman ion source, Faraday cup, and quartz crystal microbalance. The results are compared to theoretical models. The accuracy of the in situ weight-loss method was verified by thickness-decrease measurements using grazing incidence x-ray reflectometry, and results from both methods are in good agreement. These results provide accurate data sets for theoretical modeling in the near-threshold sputter regime and are of relevance for (optical) surfaces exposed to plasmas, as, for instance, in extreme ultraviolet photolithography.

36 MATERIALS SCIENCE↗

Induced Current Characteristics Due to Laser Induced Plasma and Its Application to Laser Processing Monitoring

In laser processing, suitable conditions for laser and gas play important role in ensuring a high quality of processing. To determine suitable conditions, we employed the electromagnetic phenomena associated with laser plasma generation. An electrode circuit was utilised to detect induced current due to the fast electrons propelled from the material during laser material processing. The characteristics of induced current were examined by changing parameters such as supplied voltage, laser pulse energy, number of laser shots, and type of ambient gas. These characteristics were compared with the optical emission characteristics. It was shown that the induced current technique proposed in this study is much more sensitive than the optical method in monitoring laser processing, that is to determine the precise focusing condition, and to accurately determine the moment of completion of laser beam penetration. In this study it was also shown that the induced current technique induced by CW CO{sub 2} laser can be applied in industrial material processing for monitoring the penetration completion in a stainless steel plate drilling process.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fast electron propagation in Ti foils irradiated with sub-picosecond laser pulses at Iλ{sup 2}>10{sup 18} Wcm{sup −2}μm{sup 2}

We have studied the propagation of fast electrons through laser irradiated Ti foils by monitoring the emission of hard X-rays and K-α radiation from bare foils and foils backed by a thick epoxy layer. Key observations include strong refluxing of electrons and divergence of the electron beam in the foil with evidence of magnetic field collimation. Our diagnostics have allowed us to estimate the fast electron temperature and fraction of laser energy converted to fast electrons. We have observed clear differences between the fast electron temperatures observed with bare and epoxy backed targets which may be due to the effects of refluxing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electrochemical flowcell for in-situ investigations by soft x-ray absorption and emission spectroscopy

A new liquid flow-cell designed for electronic structure investigations at the liquid-solid interface by soft X-ray absorption and emission spectroscopy is presented. A thin membrane serves simultaneously as a substrate for the working electrode and solid state samples as well as for separating the liquid from the surrounding vacuum conditions. In combination with counter and reference electrodes this approach allows in-situ studies of electrochemical deposition processes and catalytic reactions at the liquid-solid interface in combination with potentiostatic measurements. As model system in-situ monitoring of the deposition process of Co metal from a 10 mM CoCl{sub 2} aqueous solution by X-ray absorption and emission spectroscopy is presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cosmic rays muon flux measurements at Belgrade shallow underground laboratory

The Belgrade underground laboratory is a shallow underground one, at 25 meters of water equivalent. It is dedicated to low-background spectroscopy and cosmic rays measurement. Its uniqueness is that it is composed of two parts, one above ground, the other bellow with identical sets of detectors and analyzing electronics thus creating opportunity to monitor simultaneously muon flux and ambient radiation. We investigate the possibility of utilizing measurements at the shallow depth for the study of muons, processes to which these muons are sensitive and processes induced by cosmic rays muons. For this purpose a series of simulations of muon generation and propagation is done, based on the CORSIKA air shower simulation package and GEANT4. Results show good agreement with other laboratories and cosmic rays stations.

79 ASTRONOMY AND ASTROPHYSICS↗

Prototyping of beam position monitor for medium energy beam transport section of RAON heavy ion accelerator

A heavy ion accelerator, RAON is going to be built by Rare Isotope Science Project in Korea. Its target is to accelerate various stable ions such as uranium, proton, and xenon from electron cyclotron resonance ion source and some rare isotopes from isotope separation on-line. The beam shaping, charge selection, and modulation should be applied to the ions from these ion sources because RAON adopts a superconducting linear accelerator structure for beam acceleration. For such treatment, low energy beam transport, radio frequency quadrupole, and medium energy beam transport (MEBT) will be installed in injector part of RAON accelerator. Recently, development of a prototype of stripline beam position monitor (BPM) to measure the position of ion beams in MEBT section is under way. In this presentation, design of stripline, electromagnetic (EM) simulation results, and RF measurement test results obtained from the prototyped BPM will be described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Near infrared laser annealing of CdTe and in-situ measurement of the evolution of structural and optical properties

The high performance of polycrystalline CdTe thin film solar cells is enabled by annealing in the presence of Cl. This process is typically carried out for tens of minutes resulting in reduction of defect states within the bandgap among other beneficial effects. In this work, we investigate laser annealing as a means of rapidly annealing CdTe using a continuous wave sub-bandgap 1064 nm laser. The partial transmission of the beam allows us to monitor the annealing process in-situ and in real time. We find that optoelectronic and structural changes occur through two distinct kinetic processes resulting in the removal of deep defects and twinned regions, respectively. A multilayer optical model including surface roughness is used to interpret both the in-situ transmission as well as ex-situ reflectivity measurements. These experiments demonstrate beneficial material changes resulting from sub-bandgap laser-driven CdCl{sub 2} treatment of CdTe in minutes, which is an important step towards accelerating the processing of the CdTe absorber layer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurements and modeling of total solar irradiance in X-class solar flares

The Total Irradiance Monitor (TIM) from NASA's SOlar Radiation and Climate Experiment can detect changes in the total solar irradiance (TSI) to a precision of 2 ppm, allowing observations of variations due to the largest X-class solar flares for the first time. Presented here is a robust algorithm for determining the radiative output in the TIM TSI measurements, in both the impulsive and gradual phases, for the four solar flares presented in Woods et al., as well as an additional flare measured on 2006 December 6. The radiative outputs for both phases of these five flares are then compared to the vacuum ultraviolet (VUV) irradiance output from the Flare Irradiance Spectral Model (FISM) in order to derive an empirical relationship between the FISM VUV model and the TIM TSI data output to estimate the TSI radiative output for eight other X-class flares. This model provides the basis for the bolometric energy estimates for the solar flares analyzed in the Emslie et al. study.

79 ASTRONOMY AND ASTROPHYSICS↗

AN INDEPENDENT ANALYSIS OF THE BROWN DWARF ATMOSPHERE MONITORING (BAM) DATA: LARGE-AMPLITUDE VARIABILITY IS RARE OUTSIDE THE L/T TRANSITION

Observations of variability can provide valuable information about the processes of cloud formation and dissipation in brown dwarf atmospheres. Here we report the results of an independent analysis of archival data from the Brown dwarf Atmosphere Monitoring (BAM) program. Time series data for 14 L and T dwarfs reported to be significantly variable over timescales of hours were analyzed. We confirm large-amplitude variability (amplitudes >2%) for 4 out of 13 targets and place upper limits of 0.7%-1.6% on variability in the remaining sample. For two targets we find evidence of weak variability at amplitudes of 1.3% and 1.6%. Based on our revised classification of variable objects in the BAM study, we find strong variability outside the L/T transition to be rare at near infrared wavelengths. From a combined sample of 81 L0-T9 dwarfs from the revised BAM sample and the variability survey of Radigan et al., we infer an overall observed frequency for large-amplitude variability outside the L/T transition of 3.2{sub −1.8}{sup +2.8}%, in contrast to 24{sub −9}{sup +11}% for L9-T3.5 spectral types. We conclude that while strong variability is not limited to the L/T transition, it occurs more frequently in this spectral type range, indicative of larger or more highly contrasting cloud features at these spectral types.

79 ASTRONOMY AND ASTROPHYSICS↗

OPTICAL SPECTRAL OBSERVATIONS OF A FLICKERING WHITE-LIGHT KERNEL IN A C1 SOLAR FLARE

We analyze optical spectra of a two-ribbon, long-duration C1.1 flare that occurred on 2011 August 18 within AR 11271 (SOL2011-08-18T15:15). The impulsive phase of the flare was observed with a comprehensive set of space-borne and ground-based instruments, which provide a range of unique diagnostics of the lower flaring atmosphere. Here we report the detection of enhanced continuum emission, observed in low-resolution spectra from 3600 Å to 4550 Å acquired with the Horizontal Spectrograph at the Dunn Solar Telescope. A small, ≤0.''5 (10{sup 15} cm{sup 2}) penumbral/umbral kernel brightens repeatedly in the optical continuum and chromospheric emission lines, similar to the temporal characteristics of the hard X-ray variation as detected by the Gamma-ray Burst Monitor on the Fermi spacecraft. Radiative-hydrodynamic flare models that employ a nonthermal electron beam energy flux high enough to produce the optical contrast in our flare spectra would predict a large Balmer jump in emission, indicative of hydrogen recombination radiation from the upper flare chromosphere. However, we find no evidence of such a Balmer jump in the bluemost spectral region of the continuum excess. Just redward of the expected Balmer jump, we find evidence of a ''blue continuum bump'' in the excess emission which may be indicative of the merging of the higher order Balmer lines. The large number of observational constraints provides a springboard for modeling the blue/optical emission for this particular flare with radiative-hydrodynamic codes, which are necessary to understand the opacity effects for the continuum and emission line radiation at these wavelengths.

79 ASTRONOMY AND ASTROPHYSICS↗

THE FIRST HUNDRED BROWN DWARFS DISCOVERED BY THE WIDE-FIELD INFRARED SURVEY EXPLORER (WISE)

We present ground-based spectroscopic verification of 6 Y dwarfs (see also Cushing et al.), 89 T dwarfs, 8 L dwarfs, and 1 M dwarf identified by the Wide-field Infrared Survey Explorer (WISE). Eighty of these are cold brown dwarfs with spectral types {>=}T6, six of which have been announced earlier by Mainzer et al. and Burgasser et al. We present color-color and color-type diagrams showing the locus of M, L, T, and Y dwarfs in WISE color space. Near-infrared and, in a few cases, optical spectra are presented for these discoveries. Near-infrared classifications as late as early Y are presented and objects with peculiar spectra are discussed. Using these new discoveries, we are also able to extend the optical T dwarf classification scheme from T8 to T9. After deriving an absolute WISE 4.6 {mu}m (W2) magnitude versus spectral type relation, we estimate spectrophotometric distances to our discoveries. We also use available astrometric measurements to provide preliminary trigonometric parallaxes to four of our discoveries, which have types of L9 pec (red), T8, T9, and Y0; all of these lie within 10 pc of the Sun. The Y0 dwarf, WISE 1541-2250, is the closest at 2.8{sup +1.3}{sub -0.6} pc; if this 2.8 pc value persists after continued monitoring, WISE 1541-2250 will become the seventh closest stellar system to the Sun. Another 10 objects, with types between T6 and >Y0, have spectrophotometric distance estimates also placing them within 10 pc. The closest of these, the T6 dwarf WISE 1506+7027, is believed to fall at a distance of {approx}4.9 pc. WISE multi-epoch positions supplemented with positional info primarily from the Spitzer/Infrared Array Camera allow us to calculate proper motions and tangential velocities for roughly one-half of the new discoveries. This work represents the first step by WISE to complete a full-sky, volume-limited census of late-T and Y dwarfs. Using early results from this census, we present preliminary, lower limits to the space density of these objects and discuss constraints on both the functional form of the mass function and the low-mass limit of star formation.

79 ASTRONOMY AND ASTROPHYSICS↗

SCALER MODE OF THE AUGER OBSERVATORY AND SUNSPOTS

Recent data from the Auger Observatory on low-energy secondary cosmic ray particles are analyzed to study temporal correlations together with data on the daily sunspot numbers and neutron monitor data. Standard spectral analysis demonstrates that the available data show 1/f {sup {beta}} fluctuations with {beta} Almost-Equal-To 1 in the low-frequency range. All data behave like Brownian fluctuations in the high-frequency range. The existence of long-range correlations in the data was confirmed by detrended fluctuation analysis. The real data confirmed the correlation between the scaling exponent of the detrended analysis and the exponent of the spectral analysis.

79 ASTRONOMY AND ASTROPHYSICS↗