Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Pitfalls of Transparency: Lessons Learned from the Milford Flats Fire

The Community Environmental Monitoring Program (CEMP) consists of a network of 29 radiation and weather monitoring stations located over a 160,000-km2 area of southern Nevada, southwestern Utah, and southeastern California. The program provides stakeholders with a hands-on role in the monitoring for airborne radioactivity that could result from ongoing or past activities on the Nevada Test Site (NTS). The CEMP’s mission includes provisions for the transparency of the monitoring data as well as public accessibility to these data. This is accomplished through direct stakeholder participation, public outreach, and near real-time uploads of monitoring data to a publicly accessible web site located at http://cemp.dri.edu/. In early July 2007, a lightning strike ignited a wildfire just outside the city of Milford in southeastern Utah. This fire, named the Milford Flats Fire, grew rapidly and eventually became the largest wildfire in recorded history in the state, burning approximately 567 square miles. At about the same time, the pressurized ion chamber (PIC) located at the CEMP station in Milford began reporting average exposure rates that ranged from four to seven times normal for the area. Initially, it was believed that elevated readings could be a result of gamma-emitting radon progeny released by the fire and transported in smoke plumes. The U.S. Department of Energy issued a press release offering this as a possible first explanation, and the release received a great amount of attention, particularly in the state of Utah, where concerns were expressed that the fire could be causing re-suspension of radionuclides associated with fallout from past nuclear testing at the NTS. Subsequent analyses of particulate air filter samples obtained from the Milford station, as well as an examination of the data reported by the PIC, the timing of the incident, and diagnostic testing on the PIC, showed that the abnormal gamma readings were a result of instrument malfunction. WM2008 Conference, February 24-28, 2008, Phoenix, AZ This paper will review the data from the PIC and the analytical results of air filter samples collected at Milford, and present lessons learned from the Milford Flats Fire Incident on providing real-time access to monitoring data for the public.

54 ENVIRONMENTAL SCIENCES↗

KPiX, An Array of Self Triggered Charge Sensitive Cells Generating Digital Time and Amplitude Information

The Silicon Detector proposed for the International Linear Collider (ILC) requires electronic read-out that can be tightly coupled to the silicon detectors envisioned for the tracker and the electromagnetic calorimeter. The KPiX is a 1024-channel read-out chip that bump-bonds to the detector and communicates through a few digital signals, power, and detector bias. The KPiX front-end is a low-noise dual-range charge-amplifier with a dynamic range of 17 bit, achieved by autonomous switching of the feedback capacitor. The device takes advantage of the ILC duty cycle of 1 ms trains at 5 Hz rate by lowering the supply current after the data acquisition cycle for an average power consumption of <20 {micro}W/channel. During the 1 ms train, up to four events exceeding a programmable threshold can be stored, the amplitude as a voltage on a capacitor for subsequent digitization, the event time in digital format. The chip can be configured for other than ILC applications.

43 PARTICLE ACCELERATORS↗

Problems encountered in fluctuating flame temperature measurements by thermocouple.

Some thermocouple experiments were carried out in order to obtain sensitivity of thermocouple readings to fluctuations in flames and to determine if the average thermocouple reading was representative of the local volume temperature for fluctuating flames. The thermocouples considered were an exposed junction thermocouple and a fully sheathed thermocouple with comparable time constants. Either the voltage signal or indicated temperature for each test was recorded at sampling rates between 300-4,096 Hz. The trace was then plotted with respect to time or sample number so that time variation in voltage or temperature could be visualized and the average indicated temperature could be determined. For experiments where high sampling rates were used, the signal was analyzed using Fast Fourier Transforms (FFT) to determine the frequencies present in the thermocouple signal. This provided a basic observable as to whether or not the probe was able to follow flame oscillations. To enhance oscillations, for some experiments, the flame was forced. An analysis based on thermocouple time constant, coupled with the transfer function for a sinusoidal input was tested against the experimental results.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dose Assessments to the Hands of Radiopharmaceutical Workers

This paper describes the characterization of radiation doses to the hands of nuclear medicine technicians resulting from the handling of radiopharmaceuticals. Radiation monitoring using ring dosimeters indicates that finger dosimeters may overestimate or underestimate the radiation doses to the skin that are used to show compliance with applicable regulations depending on the nature of the particular procedure and the radioisotope being handled. To better understand the parameters governing the absorbed dose distributions, a detailed model of the hands was created and used in Monte Carlo simulations of selected nuclear medicine procedures. Simulations on realistic configurations typical for workers handling radiopharmaceuticals were performed for a range of energies of the source photons. The lack of charged-particle equilibrium necessitated full photon-electron coupled transport calculations. The results show that the dose to different regions of the fingers can differ substantially from the dosimeters' readings when the dosimeters are located at the base of the finger. We tried to identify consistent patterns that relate the actual dose to the dosimeter readings. These patterns depend on the specific work conditions and can be used to better assess the absorbed dose to different regions of the exposed skin.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High resolution BPMS with integrated gain correction system

High resolution beam position monitors (BPM) are an essential tool to achieve and reproduce a low vertical beam emittance at the KEK Accelerator Test Facility (ATF) damping ring. The ATF damping ring (DR) BPMs are currently upgraded with new high resolution read-out electronics. Based on analog and digital down-conversion techniques, the upgrade includes an automatic gain calibration system to correct for slow drift effects and ensure high reproducible beam position readings. The concept and its technical realization, as well as preliminary results of beam studies are presented.

43 PARTICLE ACCELERATORS↗

Metagenomic Sequencing of an In Vitro-Simulated Microbial Community

Background: Microbial life dominates the earth, but many species are difficult or even impossible to study under laboratory conditions. Sequencing DNA directly from the environment, a technique commonly referred to as metagenomics, is an important tool for cataloging microbial life. This culture-independent approach involves collecting samples that include microbes in them, extracting DNA from the samples, and sequencing the DNA. A sample may contain many different microorganisms, macroorganisms, and even free-floating environmental DNA. A fundamental challenge in metagenomics has been estimating the abundance of organisms in a sample based on the frequency with which the organism's DNA was observed in reads generated via DNA sequencing. Methodology/Principal Findings: We created mixtures of ten microbial species for which genome sequences are known. Each mixture contained an equal number of cells of each species. We then extracted DNA from the mixtures, sequenced the DNA, and measured the frequency with which genomic regions from each organism was observed in the sequenced DNA. We found that the observed frequency of reads mapping to each organism did not reflect the equal numbers of cells that were known to be included in each mixture. The relative organism abundances varied significantly depending on the DNA extraction and sequencing protocol utilized. Conclusions/Significance: We describe a new data resource for measuring the accuracy of metagenomic binning methods, created by in vitro-simulation of a metagenomic community. Our in vitro simulation can be used to complement previous in silico benchmark studies. In constructing a synthetic community and sequencing its metagenome, we encountered several sources of observation bias that likely affect most metagenomic experiments to date and present challenges for comparative metagenomic studies. DNA preparation methods have a particularly profound effect in our study, implying that samples prepared with different protocols are not suitable for comparative metagenomics.

99 GENERAL AND MISCELLANEOUS↗

Space charge dosimeters for extremely low power measurements of radiation in shipping containers

Methods and apparatus are described for space charge dosimeters for extremely low power measurements of radiation in shipping containers. A method includes insitu polling a suite of passive integrating ionizing radiation sensors including reading-out dosimetric data from a first passive integrating ionizing radiation sensor and a second passive integrating ionizing radiation sensor, where the first passive integrating ionizing radiation sensor and the second passive integrating ionizing radiation sensor remain situated where the dosimetric data was integrated while reading-out. Another method includes arranging a plurality of ionizing radiation sensors in a spatially dispersed array; determining a relative position of each of the plurality of ionizing radiation sensors to define a volume of interest; collecting ionizing radiation data from at least a subset of the plurality of ionizing radiation sensors; and triggering an alarm condition when a dose level of an ionizing radiation source is calculated to exceed a threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identifying messaging completion in a parallel computer by checking for change in message received and transmitted count at each node

Methods, parallel computers, and products are provided for identifying messaging completion on a parallel computer. The parallel computer includes a plurality of compute nodes, the compute nodes coupled for data communications by at least two independent data communications networks including a binary tree data communications network optimal for collective operations that organizes the nodes as a tree and a torus data communications network optimal for point to point operations that organizes the nodes as a torus. Embodiments include reading all counters at each node of the torus data communications network; calculating at each node a current node value in dependence upon the values read from the counters at each node; and determining for all nodes whether the current node value for each node is the same as a previously calculated node value for each node. If the current node is the same as the previously calculated node value for all nodes of the torus data communications network, embodiments include determining that messaging is complete and if the current node is not the same as the previously calculated node value for all nodes of the torus data communications network, embodiments include determining that messaging is currently incomplete.

97 MATHEMATICS AND COMPUTING↗

Development of an In-Situ Data Logging System for Multiple Trace Gas Analyzers

A field deployable in-situ data logging system was developed at Pacific Northwest National Laboratory for trace gases including carbon monoxide (CO), ozone (O3), sulfur dioxide (SO2), and nitrogen oxides including nitric oxide, nitrogen dioxide, and odd nitrogens (NO/NO2/NOx). On-line data acquisition and calibration are essential to analysis of observables and data integrity. As such, a program was written to control the communication between the data logger and each analyzer in Logger Net, a program used to communicate with the data logger. Analog outputs were collected by a CR-23X Campbell data logger between July 2, 2007 and August 7, 2007 in Richland, Washington, with data being averaged every minute. A dynamic calibrator was used to calibrate the instruments using a gas standard with NIST-certified concentration. The National Oceanic and Atmospheric Administration’s HYSPLIT model was used to create a backward and forward trajectory of air during an episode of peak O3 to determine pollutant sources and sinks. Data collected through the duration of the sampling period revealed several observations. Concentrations of all trace gases were low, due in part to the scarcity of pollutant sources in the region. The average SO2 reading was less than 0.05 ppb over the period, whereas mixing ratios of 1-20 ppb are more common in rural-suburban environments. NO, NO2, and NOx averaged 0.3, 12.2, and 12.8 ppb, respectively, while the average CO was 228.5 ppb. Typical O3 in similar environments peaks at 80-150 ppb, but the highest mixing ratio of O3 observed was less than 45 ppb. HYSPLIT offered no apparent source for additional pollutants during the high O3 episode, but increased photochemistry due to high temperatures would explain the increase in O3. Both SO2 and NO readings registered near the detection limit of the instruments, and displayed a trend similar to background noise. The development of the data logging and display system for key trace gas species is an essential measurement capability. It will facilitate future field deployment either on the ground or aboard aircraft with minor modifications. The calibration coefficients determined in this study would provide useful references of the instrument performance characteristics. In addition, the continuous data collected could potentially be a unique data set to study atmospheric chemistry of key trace gas species in a non-urban environment.

54 ENVIRONMENTAL SCIENCES↗

Genome sequence, phylogenetic analysis, and structure-based annotation reveal metabolic potential of Chlorella sp. SLA-04

Algae are a broad class of photosynthetic eukaryotes that are phylogenetically and physiologically diverse. Most of the phylogenetic diversity has been inferred from 18S rDNA sequencing since there are only a few complete genomes available in public databases. Here we use ultra-long-read Nanopore sequencing to determine a gapless, telomere-to-telomere complete genome sequence of Chlorella sp. SLA-04, previously described as Chlorella sorokiniana SLA-04. Chlorella sp. SLA-04 is a green alga that grows to high cell density in a wide variety of environments - high and neutral pH, high and low alkalinity, and high and low salinity. SLA-04's ability to grow in high pH and high alkalinity media without external CO 2 supply is favorable for large-scale algal biomass production. Phylogenetic analysis performed using ribosomal DNA and conserved protein sequences consistently reveal that Chlorella sp. SLA-04 forms a distinct lineage from other strains of Chlorella sorokiniana. We complement traditional genome annotation methods with high throughput structural predictions and demonstrate that this approach expands functional prediction of the SLA-04 proteome. Genomic analysis of the SLA-04 genome identifies the genes capable of utilizing TCA cycle intermediates to replenish cytosolic acetyl-CoA pools for lipid production. We also identify a complete metabolic pathway for sphingolipid anabolism that may allow SLA-04 to readily adapt to changing environmental conditions and facilitate robust cultivation in mass production systems. Altogether, this work clarifies the phylogeny of Chlorella sp. SLA-04 within Trebouxiophyceae and demonstrates how structural predictions can be used to improve annotation beyond sequencebased methods.

59 BASIC BIOLOGICAL SCIENCES↗

In-pixel AI for lossy data compression at source for X-ray detectors

Integrating neural networks for data compression directly in the Read-Out Integrated Circuits (ROICs), i.e. the pixelated front-end, would result in a significant reduction in off-chip data transfer, overcoming the I/O bottleneck. Our ROIC test chip (AI-In-Pixel-65) is designed in a 65 nm Low Power CMOS process for the readout of pixelated X-ray detectors. Each pixel consists of an analog front-end for signal processing and a 10b analog-to-digital converter operating at 100KSPS. Here, we compare two non-reconfigurable techniques, Principal Component Analysis (PCA) and an AutoEncoder (AE) as lossy data compression engines implemented within the pixelated area. The PCA algorithm achieves 50$×$ compression, adds one clock cycle latency, and results in a 21% increase in the pixel area. The AE achieves 70$×$ compression, adds 30 clock cycle latency, and results in a similar area increase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

In Situ Characterization of Surface Recombination in p-Si/SiO x Based Photoelectrochemical Cells

Time-resolved infrared (TRIR) and electrochemical impedance spectroscopy (EIS) were utilized to quantify surface states present at silicon oxide (SiO x ) protected crystalline p-Si electrolyte interfaces. The primary goal was to identify p-Si/SiO x photoelectrodes with both low surface recombination rates and efficient multi-electron transfer to an acceptor present in the external electrolyte. Three SiO x layers were investigated: native oxide (nOx), chemical oxide (cOx), and rapid thermal annealed (RTA) thermal oxide (tOx). Comparative study with [Ru(bpy) 3 ](PF 6 ) 2 as the electron acceptor indicated that tOx was most optimal with a small effective recombination rate, multi-electron transfer capability, and photovoltage of 500 ± 50 mV. A secondary goal was to analyze the surface recombination rates with the Shockley–Read–Hall (SRH) kinetic model. Two surface states were identified from this analysis, one closer to the CB edge (V t,1 ) and the other near the midgap (V t,2 ). EIS and SRH analyses revealed that a forming gas (5% H 2 /N 2 ) anneal (FGA) decreased surface recombination for tOx and nOx through a lower density of surface states. In the case of tOx, the infrared data indicated that V t,2 was completely removed. Here, the energetic positions of the band edges were correlated with the surface state density; low densities corresponded to more favorable potentials for inversion layer formation, which is expected to be most optimal for photocatalysis. Collectively this study indicates that the free carrier dynamics provided by TRIR represent a powerful in situ probe of the band edge and the surface state energetics in silicon based photoelectrochemical cells.

Electrochemical Impedance Spectroscopy↗

Toward Long-Term Accurate and Continuous Monitoring of Nitrate in Wastewater Using Poly(tetrafluoroethylene) (PTFE)–Solid-State Ion-Selective Electrodes (S-ISEs)

Long-term accurate and continuous monitoring of nitrate (NO 3 – ) concentration in wastewater and groundwater is critical for determining treatment efficiency and tracking contaminant transport. Current nitrate monitoring technologies, including colorimetric, chromatographic, biometric, and electrochemical sensors, are not feasible for continuous monitoring. In this work, we addressed this challenge by modifying NO 3 – solid-state ion-selective electrodes (S-ISEs) with poly(tetrafluoroethylene) (PTFE, (C 2 F 4 ) n ). The PTFE-loaded S-ISE membrane polymer matrix reduces water layer formation between the membrane and electrode/solid contact, while paradoxically, the even more hydrophobic PTFE-loaded S-ISE membrane prevents bacterial attachment despite the opposite approach of hydrophilic modifications in other antifouling sensor designs. Specifically, an optimal ratio of 5% PTFE in the S-ISE polymer matrix was determined by a series of characterization tests in real wastewater. Five percent of PTFE alleviated biofouling to the sensor surface by enhancing the negative charge (–4.5 to –45.8 mV) and lowering surface roughness (Ra: 0.56 ± 0.02 nm). It simultaneously mitigated water layer formation between the membrane and electrode by increasing hydrophobicity (contact angle: 104°) and membrane adhesion and thus minimized the reading (mV) drift in the baseline sensitivity (“data drifting”). Long-term accuracy and durability of 5% PTFE-loaded NO 3 – S-ISEs were well demonstrated in real wastewater over 20 days, an improvement over commercial sensor longevity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Time-resolved, nonequilibrium carrier dynamics in Si-on-glass thin films for photovoltaic cells

Here, a femtosecond pump–probe spectroscopy method was used to characterize the growth process and transport properties of amorphous silicon-on-glass, thin films, intended as absorbers for photovoltaic cells. We collected normalized transmissivity change (ΔT/T) waveforms and interpreted them using a comprehensive three-rate equation electron trapping and recombination model. Optically excited ~300–500 nm thick Si films exhibited a bi-exponential carrier relaxation with the characteristic times varying from picoseconds to nanoseconds depending on the film growth process. From our comprehensive trapping model, we could determine that for doped and intrinsic films with very low hydrogen dilution the dominant relaxation mode was carrier trapping; while for intrinsic films with large hydrogen content and some texture, it was the standard electron–phonon cooling. In both cases, the initial nonequilibrium relaxation was followed by Shockley–Read–Hall recombination. An excellent fit between the model and the ΔT/T experimental transients was obtained and a correlation between the Si film growth process, its hydrogen content, and the associated trap concentration was demonstrated.

14 SOLAR ENERGY↗

Coupled Process/Device Modeling and Point Defect Engineering of Cu(In,Ga)Se 2 Solar Cells

Point defects directly impact solar cell device performance by limiting the carrier lifetime. In this work, density functional theory calculations are first used to determine the formation energy and diffusion energy barriers of dominant defects in Cu(In,Ga)Se 2 . Next, continuum reaction–diffusion models are developed to analyze the redistribution of defects during manufacturing processes. We estimate defect capture cross sections using a first-principles-based approach. Here, these cross sections are combined with our calculated defect profiles and trap energy levels to parameterize a Shockley–Read–Hall recombination model, which we implement into a device simulator to predict carrier lifetimes and device performance. In that way, a predictive technology computer aided design model is built to predict and optimize the performance of Cu(In,Ga)Se 2 solar cells.

14 SOLAR ENERGY↗

Improved noise performance from the next-generation buried-channel p-MOSFET SiSeROs

The Single electron Sensitive Read Out (SiSeRO) is a novel on-chip charge detector output stage for charge-coupled device (CCD) image sensors. Developed at MIT Lincoln Laboratory, this technology uses a p-MOSFET transistor with a depleted internal gate beneath the transistor channel. The transistor source-drain current is modulated by the transfer of charge into the internal gate. At Stanford, we have developed a readout module based on the drain current of the on-chip transistor to characterize the device. In our earlier work, we characterized a number of first prototype SiSeROs with the MOSFET transistor channels at the surface layer. An equivalent noise charge (ENC) of around 15 electrons root mean square (RMS) was obtained. In this work, we examine the first buried-channel SiSeRO. Here we have achieved substantially improved noise performance of around 4.5 electrons root mean square (RMS) and a full width half maximum (FWHM) energy resolution of 132 eV at 5.9 keV, for a readout speed of 625 kpixel/s. We also discuss how digital filtering techniques can be used to further improve the SiSeRO noise performance. Additional measurements and device simulations will be essential to further mature the SiSeRO technology. This new device class presents an exciting new technology for the next-generation astronomical X-ray telescopes requiring fast, low-noise, radiation-hard megapixel imagers with moderate spectroscopic resolution.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-158: Catching Errors with Trajectory Log Files

Purpose: To present our single institution experience on catching errors with trajectory log file analysis. The reported causes of failures, probability of occurrences (O), severity of effects (S), and the probability of the failures to be undetected (D) could be added to guidelines of FMEA analysis. Methods: From March 2013 to March 2014, 19569 patient treatment fields/arcs were analyzed. This work includes checking all 131 treatment delivery parameters for all patients, all treatment sites and all treatment delivery fractions. TrueBeam trajectory log files for all treatment field types as well as all imaging types were accessed, read in every 20ms, and every control point (total of 37 million parameters) compared to the physician approved plan in the planning system. Results: Couch angle outlier occurrence: N= 327, range = −1.7 −1.2 deg; gantry angle outlier occurrence: N =59, range = 0.09 – 5.61 deg, collimator angle outlier occurrence: N = 13, range = −0.2 – 0.2 deg. VMAT cases have slightly larger variations in mechanical parameters. MLC: 3D single control point fields have a maximum deviation of 0.04 mm, 39 step and shoot IMRT cases have MLC −0.3 – 0.5 mm deviations, all (1286) VMAT cases have −0.9 – 0.7 mm deviations. Two possible serious errors were found: 1) A 4 cm isocenter shift for the PA beam of an AP-PA pair, under-dosing a portion of PTV by 25%. 2) Delivery with MLC leaves abutted behind the jaws as opposed to the midline as planned, leading to a under-dosing of a small volume of the PTV by 25%, by just the boost plan. Due to their error origin, neither of these errors could have been detected by pre-treatment verification. Conclusion: Performing Trajectory Log file analysis could catch typically undetected errors to avoid potentially adverse incidents.

60 APPLIED LIFE SCIENCES↗

Hidden Markov Model: a shortest unique representative approach to detect the protein toxins, virulence factors and antibiotic resistance genes

Objective: Currently, next generation sequencing (NGS) is widely used to decode potential novel or variant pathogens both in emergent outbreaks and in routine clinical practice. However, the efficient identification of novel or diverged pathogenomic compositions remains a big challenge. It is especially true for short DNA sequence fragments from NGS, since sequence similarity searching is vulnerable to false negatives or false positives, as is mismatching or matching with unrelated proteins. Therefore, this study aimed to establish a bioinformatics approach that can generate unique motif sequences for profiling searching, resulting in high specificity and sensitivity. Results: In this study, we introduced a Shortest Unique Representative Hidden Markov Model (HMM) approach to identify bacterial toxin, virulence factor (VF), and antimicrobial resistance (AR) in short sequence reads. We first construct unique representative domain sequences of toxin genes, VFs, and ARs to avoid potential false positives, and then to use HMM models to accurately identify potential toxin, VF, and AR fragments. The benchmark shows this approach can achieve relatively high specificity and sensitivity if the appropriate cutoff value is applied. Our approach can be used to recognize the protein sequences of known toxins and pathogens, identifies their common characteristics and then searches for similar sequences in other organisms.

59 BASIC BIOLOGICAL SCIENCES↗