Search NASA⌕ Search

SEARCH · Search NASA

Results for “Real time analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Downdating a time-varying square root information filter

A new method to efficiently downdate an estimate and covariance generated by a discrete time Square Root Information Filter (SRIF) is presented. The method combines the QR factor downdating algorithm of Gill and the decentralized SRIF algorithm of Bierman. Efficient removal of either measurements or a priori information is possible without loss of numerical integrity. Moreover, the method includes features for detecting potential numerical degradation. Performance on a 300 parameter system with 5800 data points shows that the method can be used in real time and hence is a promising tool for interactive data analysis. Additionally, updating a time-varying SRIF filter with either additional measurements or a priori information proceeds analogously.

Muellerschoen, Ronald J.↗

An expert system/ion trap mass spectrometry approach for life support systems monitoring

Efforts to develop sensor and control system technology to monitor air quality for life support have resulted in the development and preliminary testing of a concept based on expert systems and ion trap mass spectrometry (ITMS). An ITMS instrument provides the capability to identify and quantitate a large number of suspected contaminants at trace levels through the use of a variety of multidimensional experiments. An expert system provides specialized knowledge for control, analysis, and decision making. The system is intended for real-time, on-line, autonomous monitoring of air quality. The key characteristics of the system, performance data and analytical capabilities of the ITMS instrument, the design and operation of the expert system, and results from preliminary testing of the system for trace contaminant monitoring are described.

Palmer, Peter T.↗

EOS-AM precision pointing verification

The Earth Observing System (EOS) AM mission requires tight pointing knowledge to meet scientific objectives, in a spacecraft with low frequency flexible appendage modes. As the spacecraft controller reacts to various disturbance sources and as the inherent appendage modes are excited by this control action, verification of precision pointing knowledge becomes particularly challenging for the EOS-AM mission. As presently conceived, this verification includes a complementary set of multi-disciplinary analyses, hardware tests and real-time computer in the loop simulations, followed by collection and analysis of hardware test and flight data and supported by a comprehensive data base repository for validated program values.

Throckmorton, A.↗

Summary Report of Mission Acceleration Measurements for STS-75, Launched February 22, 1996

Two accelerometers provided acceleration data during the STS-75 mission in support of the third United States Microgravity Payload (USMP-3) experiments. The Orbital Acceleration Research Experiment (OARE) and the Space Acceleration Measurement System (SAMS) provided a measure of the microgravity environment of the Space Shuttle Columbia. The OARE provided investigators with quasi-steady acceleration measurements after about a six hour time lag dictated by downlink constraints. SAMS data were downlinked in near-real-time and recorded on-board for post-mission analysis. An overview of the mission is provided as are brief discussions of these two accelerometer systems. Data analysis techniques used to process SAMS and OARE data are discussed Using a combination of these techniques, the microgravity environment related to several different Orbiter, crew, and experiment operations is presented and interpreted. The microgravity environment represented by SAMS and OARE data is comparable to the environments measured by the instruments on earlier microgravity science missions. The OARE data compared well with predictions of the quasi-steady environment. The SAMS data show the influence of thruster firings and crew motion (transient events) and of crew exercise, Orbiter systems, and experiment operations (oscillatory events). Thruster activity on this mission appears to be somewhat more frequent than on other microgravity missions with the combined firings of the F5L and F5R jets producing significant acceleration transients. The specific crew activities performed in the middeck and flight deck, the SPREE table rotations, the waste collection system compaction, and the fuel cell purge had negligible effects on the microgravity environment of the USMP-3 carriers. The Ku band antenna repositioning activity resulted in a brief interruption of the ubiquitous 17 Hz signal in the SAMS data. In addition, the auxiliary power unit operations during the Flight Control System checkout appeared to have a significant impact on the microgravity environment.

Rogers, Melissa J. B.↗

Principal Investigator Microgravity Services: USMP-3

Two accelerometers provided acceleration data during the STS-75 mission in support of the third United States Microgravity Payload (USMP-3) experiments. The Orbital Acceleration Research Experiment (OARE) and the Space Acceleration Measurement System (SAMS) provided a measure of the microgravity environment of the Space Shuttle Columbia. The OARE provided investigators with quasi-steady acceleration measurements after about a six hour time lag dictated by downlink constraints. SAMS data were downlinked in near-real-time and recorded on-board for post-mission analysis. These two accelerometer systems are briefly described. Using a combination of data analysis techniques, the microgravity environment related to several different Orbiter, crew, and experiment operations is presented and interpreted. The microgravity environment represented by SAMS and OARE data is comparable to the environments measured by these instruments on earlier microgravity science missions. Thruster activity on this mission seen in the SAMS data appear to be more frequent than on other microgravity missions with the combined firings of the F5L and F5R jets producing significant acceleration transients. Of the events studied, the crew activities performed in the middeck and flight deck, SPREE table rotations, a waste collection system compaction, and a fuel cell purge had negligible effects on the microgravity environment of the USMP-3 carriers. The Ku band antenna repositioning activity resulted in a brief interruption of the ubiquitous 17 Hz signal in the SAMS data. In addition, the auxiliary power unit operations during the Flight Control System checkout appeared to have a significant impact on the microgravity environment.

Rogers, Melissa J. B.↗

Microgravity Environment on the International Space Station

A primary feature of the International Space Station will be its microgravity environment--an environment in which the effects of gravity are drastically reduced. The International Space Station design has been driven by a long-standing, high-level requirement for a microgravity mode of operation. Various types of data are gathered when science experiments are conducted. The acceleration levels experienced during experiment operation should be factored into the analysis of the results of most microgravity experiments. To this end, the Space Acceleration Measurement System records the acceleration levels to support microgravity researchers for nearly three years of International Space Station operations. The Principal Investigator Microgravity Services project assists the experiments principal investigators with their analysis of the acceleration (microgravity) environment. The Principal Investigator Microgravity Services project provides cataloged data, periodic analysis summary reports, specialized reports for experiment teams, and real-time data in a variety of user-defined formats. Characterization of the various microgravity carriers (e.g., Shuttle and International Space Station) is also accomplished for the experiment teams. Presented in this paper will be a short description of how microgravity disturbances may affect some experiment classes, a snapshot of the microgravity environment, and a view into how well the space station is expected to meet the user requirements.

DeLombard, Richard↗

Turbofan Engine Simulated in a Graphical Simulation Environment

Recently, there has been an increase in the development of intelligent engine technology with advanced active component control. The computer engine models used in these control studies are component-level models (CLM), models that link individual component models of state space and nonlinear algebraic equations, written in a computer language such as Fortran. The difficulty faced in performing control studies on Fortran-based models is that Fortran is not supported with control design and analysis tools, so there is no means for implementing real-time control. It is desirable to have a simulation environment that is straightforward, has modular graphical components, and allows easy access to health, control, and engine parameters through a graphical user interface. Such a tool should also provide the ability to convert a control design into real-time code, helping to make it an extremely powerful tool in control and diagnostic system development. Simulation time management is shown: Mach number versus time, power level angle versus time, altitude versus time, ambient temperature change versus time, afterburner fuel flow versus time, controller and actuator dynamics, collect initial conditions, CAD output, and component-level model: CLM sensor, CAD input, and model output. The Controls and Dynamics Technologies Branch at the NASA Glenn Research Center has developed and demonstrated a flexible, generic turbofan engine simulation platform that can meet these objectives, known as the Modular Aero-Propulsion System Simulation (MAPSS). MAPSS is a Simulink-based implementation of a Fortran-based, modern high pressure ratio, dual-spool, low-bypass, military-type variable-cycle engine with a digital controller. Simulink (The Mathworks, Natick, MA) is a computer-aided control design and simulation package allows the graphical representation of dynamic systems in a block diagram form. MAPSS is a nonlinear, non-real-time system composed of controller and actuator dynamics (CAD) and component-level model (CLM) modules. The controller in the CAD module emulates the functionality of a digital controller, which has a typical update rate of 50 Hz. The CLM module simulates the dynamics of the engine components and uses an update rate of 2500 Hz, which is needed to iterate to balance mass and energy among system components. The actuators in the CAD module use the same sampling rate as those in the CLM. Two graphs of normalized spool speed versus time in seconds and one graph of normalized average metal temperature versus time in seconds is shown. MAPSS was validated via open-loop and closed-loop comparisons with the Fortran simulation. The preceding plots show the normalized results of a closed-loop comparison looking at three states of the model: low-pressure spool speed, high-pressure spool speed, and the average metal temperature measured from the combustor to the high-pressure turbine. In steady state, the error between the simulations is less than 1 percent. During a transient, the difference between the simulations is due to a correction in MAPSS that prevents the gas flow in the bypass duct inlet from flowing forward instead of toward the aft end, which occurs in the Fortran simulation. A comparison between MAPSS and the Fortran model of the bypass duct inlet flow for power lever angles greater than 35 degrees is shown.

Parker, Khary I.↗

Potential Utility of the Real-Time TMPA-RT Precipitation Estimates in Streamflow Prediction

We investigate the potential utility of the real-time Tropical Rainfall Measuring Mission (TRMM) Multi-satellite Precipitation Analysis (TMPA-RT) data for streamflow prediction, both through direct comparisons of TMPA-RT estimates with a gridded gauge product, and through evaluation of streamflow simulations over four tributaries of La Plata Basin (LPB) in South America using the two precipitation products. Our assessments indicate that the relative accuracy and the hydrologic performance of TMPA-RT-based streamflow simulations generally improved after February 2005. The improvements in TMPA-RT since 2005 are closely related to upgrades in the TMPA-RT algorithm in early February, 2005 which include use of additional microwave sensors (AMSR-E and AMSU-B) and implementation of different calibration schemes. Our work suggests considerable potential for hydrologic prediction using purely satellite-derived precipitation estimates (no adjustments by in situ gauges) in parts of the globe where in situ observations are sparse.

Su, Fengge↗

Common Bolted Joint Analysis Tool

Common Bolted Joint Analysis Tool (comBAT) is an Excel/VB-based bolted joint analysis/optimization program that lays out a systematic foundation for an inexperienced or seasoned analyst to determine fastener size, material, and assembly torque for a given design. Analysts are able to perform numerous what-if scenarios within minutes to arrive at an optimal solution. The program evaluates input design parameters, performs joint assembly checks, and steps through numerous calculations to arrive at several key margins of safety for each member in a joint. It also checks for joint gapping, provides fatigue calculations, and generates joint diagrams for a visual reference. Optimum fastener size and material, as well as correct torque, can then be provided. Analysis methodology, equations, and guidelines are provided throughout the solution sequence so that this program does not become a "black box:" for the analyst. There are built-in databases that reduce the legwork required by the analyst. Each step is clearly identified and results are provided in number format, as well as color-coded spelled-out words to draw user attention. The three key features of the software are robust technical content, innovative and user friendly I/O, and a large database. The program addresses every aspect of bolted joint analysis and proves to be an instructional tool at the same time. It saves analysis time, has intelligent messaging features, and catches operator errors in real time.

Imtiaz, Kauser↗

Beat-to-Beat Blood Pressure Monitor

This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes. Photoplethysmography, which measures changes in arterial blood volume, is commonly used to obtain heart rate and blood oxygen saturation. The digitized PPG signals are used as inputs into the beat-to-beat blood pressure measurement algorithm.

Lee, Yong Jin↗

Beat-to-Beat Blood Pressure Monitor

This device provides non-invasive beat-to-beat blood pressure measurements and can be worn over the upper arm for prolonged durations. Phase and waveform analyses are performed on filtered proximal and distal photoplethysmographic (PPG) waveforms obtained from the brachial artery. The phase analysis is used primarily for the computation of the mean arterial pressure, while the waveform analysis is used primarily to obtain the pulse pressure. Real-time compliance estimate is used to refine both the mean arterial and pulse pressures to provide the beat-to-beat blood pressure measurement. This wearable physiological monitor can be used to continuously observe the beat-to-beat blood pressure (B3P). It can be used to monitor the effect of prolonged exposures to reduced gravitational environments and the effectiveness of various countermeasures. A number of researchers have used pulse wave velocity (PWV) of blood in the arteries to infer the beat-to-beat blood pressure. There has been documentation of relative success, but a device that is able to provide the required accuracy and repeatability has not yet been developed. It has been demonstrated that an accurate and repeatable blood pressure measurement can be obtained by measuring the phase change (e.g., phase velocity), amplitude change, and distortion of the PPG waveforms along the brachial artery. The approach is based on comparing the full PPG waveform between two points along the artery rather than measuring the time-of-flight. Minimizing the measurement separation and confining the measurement area to a single, well-defined artery allows the waveform to retain the general shape between the two measurement points. This allows signal processing of waveforms to determine the phase and amplitude changes.

Lee, Yong Jin↗

Hyperspectral Imager-Tracker

The Hyperspectral Imager-Tracker (HIT) is a technique for visualization and tracking of low-contrast, fast-moving objects. The HIT architecture is based on an innovative and only recently developed concept in imaging optics. This innovative architecture will give the Light Prescriptions Innovators (LPI) HIT the possibility of simultaneously collecting the spectral band images (hyperspectral cube), IR images, and to operate with high-light-gathering power and high magnification for multiple fast- moving objects. Adaptive Spectral Filtering algorithms will efficiently increase the contrast of low-contrast scenes. The most hazardous parts of a space mission are the first stage of a launch and the last 10 kilometers of the landing trajectory. In general, a close watch on spacecraft operation is required at distances up to 70 km. Tracking at such distances is usually associated with the use of radar, but its milliradian angular resolution translates to 100- m spatial resolution at 70-km distance. With sufficient power, radar can track a spacecraft as a whole object, but will not provide detail in the case of an accident, particularly for small debris in the onemeter range, which can only be achieved optically. It will be important to track the debris, which could disintegrate further into more debris, all the way to the ground. Such fragmentation could cause ballistic predictions, based on observations using high-resolution but narrow-field optics for only the first few seconds of the event, to be inaccurate. No optical imager architecture exists to satisfy NASA requirements. The HIT was developed for space vehicle tracking, in-flight inspection, and in the case of an accident, a detailed recording of the event. The system is a combination of five subsystems: (1) a roving fovea telescope with a wide 30 field of regard; (2) narrow, high-resolution fovea field optics; (3) a Coude optics system for telescope output beam stabilization; (4) a hyperspectral-mutispectral imaging assembly; and (5) image analysis software with effective adaptive spectral filtering algorithm for real-time contrast enhancement.

Agurok, Llya↗

MSL DSENDS EDL Analysis and Operations

This paper presents the operations experience of the JPL EDL (Entry, Descent, and Landing) trajectory simulation team, focusing on events in the week before landing and EDL itself. A brief description of the EDL trajectory simulation tool used for targeting and simulation verification analysis will be presented, including a high level discussion of the required modeling. Initialization and output interfaces used for landing hazard analysis will also be covered, along with discussion of real-time EDL event detection using radiometric Doppler data.

Entry, descent, and landing (EDL)↗

The NASA Earth Science Applied Sciences Disasters Program: Making EO Data and Expertise Available through the Disasters Mapping Portal to Inform Decision-Makers throughout the Disaster Cycle

The NASA Earth Science Applied Sciences Disasters Program promotes the use of Earth Observations (EO) to inform disaster risk reduction and resilience throughout the disaster cycle, from local to global scales, by harnessing NASA science and technology capabilities, through engagement with end users to demonstrate the value and impact of EO to support decision-making, and by supporting end users in their use of EO in decision-making while developing relationships to grow as a trusted source of relevant science and useful results. Through the NASA Earth Science Applied Sciences Disasters Program Mapping Portal, an Esri-backed hub of geospatially enabled disaster products, event-based and near-real-time products are hosted to provide end users with analysis-ready data and data services, keeping in mind their expressed EO needs. In this presentation, case studies of past events will be highlighted, showcasing how EO data and services were provided by the Program and utilized by end users during the disaster cycle. Additionally, this presentation will highlight some of the Program’s ongoing collaboration activities to assist end users in understanding and preparing for utilization of EO data from the Mapping Portal to inform their decision-making throughout the disaster cycle. Ongoing efforts to advance the science provided by the Program on the Mapping Portal through new developments and capabilities will be highlighted, and common challenges and data needs end users often encounter when using EO data and our Program’s innovative solutions to these challenges will be addressed. Furthermore, this presentation will touch on the challenges faced and the solutions created by the Mapping Portal team in managing and hosting a plethora of EO data for end users across various disciplines.

Ronan Lucey↗

Modeling and Visualization of Geomagnetic Storms at the CCMC

The Community Coordinated Modeling Center is greatly expanding activities in geospace in recent years, including the addition of new models or outputs (including WACCM-X, SAMI3-TIEGCM, HYPERS, GAMERA test runs and WAM-IPE real time outputs) that expand the range of available views or analysis activities in geospace during the upcoming Solar Maximum and Heliophysics Big Year. We are now routinely adding to a library of geomagnetic storms using anew request interface for the Space Weather Modeling Framework(SWMF). We are placing continuous run model simulation outputs as run series onto the CCMC web site where look at quick-look graphics, perform online visualization and request outputs for any day covered by the results.We demonstrate examples and results of online visualization and analysis tools that are also placed onto the cloud to support Open Science and collaborative research.

Lutz Rastaetter↗

Monitoring/Verification using DMS: TATP Example

Field-rugged and field-programmable differential mobility spectrometry (DMS) networks provide highly selective, universal monitoring of vapors and aerosols at detectable levels from persons or areas involved with illicit chemical/biological/explosives (CBE) production. CBE sensor motes used in conjunction with automated fast gas chromatography with DMS detection (GC/DMS) verification instrumentation integrated into situational operations-management systems can be readily deployed and optimized for changing application scenarios. The feasibility of developing selective DMS motes for a “smart dust” sampling approach with guided, highly selective, fast GC/DMS verification analysis is a compelling approach to minimize or prevent the illegal use of explosives or chemical and biological materials. DMS is currently one of the foremost emerging technologies for field separation and detection of gas-phase chemical species. This is due to trace-level detection limits, high selectivity, and small size. Fast GC is the leading field analytical method for gas phase separation of chemical species in complex mixtures. Low-thermal-mass GC columns have led to compact, low-power field systems capable of complete analyses in 15–300 seconds. A collaborative effort optimized a handheld, fast GC/DMS, equipped with a non-rad ionization source, for peroxide-based explosive measurements.

47 OTHER INSTRUMENTATION↗

Rapid sample classification using an open port sampling interface coupled with liquid introduction atmospheric pressure ionization mass spectrometry

An “Open Access”-like mass spectrometric platform to fully utilize the simplicity of the manual open port sampling interface for rapid characterization of unprocessed samples by liquid introduction atmospheric pressure ionization mass spectrometry has been lacking. The in-house developed integrated software with a simple, small and relatively low-cost mass spectrometry system introduced here fills this void. Software was developed to operate the mass spectrometer, to collect and process mass spectrometric data files, to build a database and to classify samples using such a database. These tasks were accomplished via the vendorprovided software libraries. Sample classification based on spectral comparison utilized the spectral contrast angle method. As a result, using the developed software platform near real-time sample classification is exemplified using a series of commercially available blue ink rollerball pens and vegetable oils. In the case of the inks, full scan positive and negative ion ESI mass spectra were both used for database generation and sample classification. For the vegetable oils, full scan positive ion mode APCI mass spectra were recorded. The overall accuracy of the employed spectral contrast angle statistical model was 95.3% and 98% in case of the inks and oils, respectively, using leave-one-out cross-validation. In conclusion, this work illustrates that an open port sampling interface/mass spectrometer combination, with appropriate instrument control and data processing software, is a viable direct liquid extraction sampling and analysis system suitable for the non-expert user and near real-time sample classification via database matching.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Trapping of Intact, Singly-Charged, Bovine Serum Albumin Ions Injected from the Atmosphere with a 10-cm Diameter, Frequency-Adjusted Linear Quadrupole Ion Trap

High-resolution real-time particle mass measurements have not been achievable because the enormous amount of kinetic energy imparted to the particles upon expansion into vacuum competes with and overwhelms the forces applied to the charged particles within the mass spectrometer. It is possible to reduce the kinetic energy of a collimated particulate ion beam through collisions with a buffer gas while radially constraining their motion using a quadrupole guide or trap over a limited mass range. Controlling the pressure drop of the final expansion into a quadrupole trap permits a much broader mass range at the cost of sacrificing collimation. To achieve high-resolution mass analysis of massive particulate ions, an efficient trap with a large tolerance for radial divergence of the injected ions was developed that permits trapping a large range of ions for on-demand injection into an awaiting mass analyzer. The design specifications required that frequency of the trapping potential be adjustable to cover a large mass range and the trap radius be increased to increase the tolerance to divergent ion injection. The large-radius linear quadrupole ion trap was demonstrated by trapping singly-charged bovine serum albumin ions for on-demand injection into a mass analyzer. Additionally, this work demonstrates the ability to measure an electrophoretic mobility cross section (or ion mobility) of singly-charged intact proteins in the low-pressure regime. This work represents a large step toward the goal of high-resolution analysis of intact proteins, RNA, DNA, and viruses.

59 BASIC BIOLOGICAL SCIENCES↗