Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL PROCESSING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Electronics Systems for the Gamma Ray Energy Tracking Nuclear Array (GRETA)

The Gamma Ray Energy Tracking Nuclear Array (GRETA), a 4-π germanium detector system capable of measuring energy and position (within better than 2mm rms) of gamma-ray interaction points and tracking multiple gamma-ray interactions, is being designed. GRETA is composed of 30 detector modules, each with four high purity germanium crystals. Four electronics modules will support the operation of the detectors: the Digitizer Module, the Signal Filter Board and the Trigger and Timing Modules. The Digitizer Module converts the analog information with analog to digital converters operating at 100 MS/s and sends the conversions through fiber optics to the Signal Filter Board. The Signal Filter Board digitally processes the data to determine the energy and timing information of the gamma interactions within a crystal. The Digitizer and Signal Filter Board send trigger information to the Trigger System. Different trigger algorithms for trigger decision are planned for the Trigger System. The Timing System provides the clock for the electronics systems and auxiliary detectors. In this paper we review the details of the planned GRETA Electronics System.

data acquisition↗

Waveform emission location determination systems and associated methods

Waveform emission location determination systems and associated methods are described. According to one aspect, a waveform emission location determination system includes a plurality of detectors configured to receive a waveform emitted by a source and to generate electrical signals corresponding to the waveform, processing circuitry configured to access data corresponding to the electrical signals generated by the detectors, use the data to determine a plurality of spheres, and wherein a surface of each of the spheres contains a location of the source when the waveform was emitted by the source, determine an intersection of the spheres, and use the intersection of the spheres to determine the location of the source when the waveform was emitted by the source.

Hughes, Michael S.↗

Novel 2D velocity estimation method for large transient events in plasmas

Dynamics of fast transient events are challenging to be analyzed with high time resolution. Such events can occur in fusion plasmas such as the filaments during edge-localized modes (ELMs). Here, we present a robust method—the spatial displacement estimation—for estimating the displacements of structures with fast dynamics from high spatial and time resolution imaging diagnostics [e.g., gas-puff imaging (GPI)] with sampling time temporal resolution. First, a background suppression method is shown, which suppresses the slowly time-evolving and spatially non-uniform background in the signal. In the second step, a two-dimensional polynomial trend subtraction method is presented to tackle the remaining polynomial order trend in the signal. After performing these pre-processing steps, the spatial displacement of the propagating structure is estimated from the two-dimensional spatial cross-correlation coefficient function calculated between consecutive frames. The method is tested for its robustness and accuracy by simulated Gaussian events and spatially displaced random noise. An example application of the method is presented on propagating ELM filaments measured by the GPI system on the National Spherical Torus Experiment spherical tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Footwear scanning systems and methods

Methods and apparatus for scanning articles, such as footwear, to provide information regarding the contents of the articles are described. According to one aspect, a footwear scanning system includes a platform configured to contact footwear to be scanned, an antenna array configured to transmit electromagnetic waves through the platform into the footwear and to receive electromagnetic waves from the footwear and the platform, a transceiver coupled with antennas of the antenna array and configured to apply electrical signals to at least one of the antennas to generate the transmitted electromagnetic waves and to receive electrical signals from at least another of the antennas corresponding to the electromagnetic waves received by the others of the antennas, and processing circuitry configured to process the received electrical signals from the transceiver to provide information regarding contents within the footwear.

47 OTHER INSTRUMENTATION↗

A new stationary gridline artifact suppression method based on the 2D discrete wavelet transform

Purpose: In digital x-ray radiography, an antiscatter grid is inserted between the patient and the image receptor to reduce scattered radiation. If the antiscatter grid is used in a stationary way, gridline artifacts will appear in the final image. In most of the gridline removal image processing methods, the useful information with spatial frequencies close to that of the gridline is usually lost or degraded. In this study, a new stationary gridline suppression method is designed to preserve more of the useful information. Methods: The method is as follows. The input image is first recursively decomposed into several smaller subimages using a multiscale 2D discrete wavelet transform. The decomposition process stops when the gridline signal is found to be greater than a threshold in one or several of these subimages using a gridline detection module. An automatic Gaussian band-stop filter is then applied to the detected subimages to remove the gridline signal. Finally, the restored image is achieved using the corresponding 2D inverse discrete wavelet transform. Results: The processed images show that the proposed method can remove the gridline signal efficiently while maintaining the image details. The spectra of a 1D Fourier transform of the processed images demonstrate that, compared with some existing gridline removal methods, the proposed method has better information preservation after the removal of the gridline artifacts. Additionally, the performance speed is relatively high. Conclusions: The experimental results demonstrate the efficiency of the proposed method. Compared with some existing gridline removal methods, the proposed method can preserve more information within an acceptable execution time.

60 APPLIED LIFE SCIENCES↗

Measurement of boosted Higgs bosons produced via vector boson fusion or gluon fusion in the H →$ \textrm{b}\overline{\textrm{b}} $ decay mode using LHC proton-proton collision data at $ \sqrt{s} $ = 13 TeV

A measurement is performed of Higgs bosons produced with high transverse momentum (p$_{T}$) via vector boson or gluon fusion in proton-proton collisions. The result is based on a data set with a center-of-mass energy of 13 TeV collected in 2016–2018 with the CMS detector at the LHC and corresponds to an integrated luminosity of 138 fb$^{−1}$. The decay of a high-p$_{T}$ Higgs boson to a boosted bottom quark-antiquark pair is selected using large-radius jets and employing jet substructure and heavy-flavor taggers based on machine learning techniques. Independent regions targeting the vector boson and gluon fusion mechanisms are defined based on the topology of two quark-initiated jets with large pseudorapidity separation. The signal strengths for both processes are extracted simultaneously by performing a maximum likelihood fit to data in the large-radius jet mass distribution. The observed signal strengths relative to the standard model expectation are $ {4.9}_{-1.6}^{+1.9} $ and $ {1.6}_{-1.5}^{+1.7} $ for the vector boson and gluon fusion mechanisms, respectively. A differential cross section measurement is also reported in the simplified template cross section framework.[graphic not available: see fulltext]

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PGC-1{alpha} accelerates cytosolic Ca{sup 2+} clearance without disturbing Ca{sup 2+} homeostasis in cardiac myocytes

Energy metabolism and Ca{sup 2+} handling serve critical roles in cardiac physiology and pathophysiology. Peroxisome proliferator-activated receptor gamma coactivator 1 alpha (PGC-1{alpha}) is a multi-functional coactivator that is involved in the regulation of cardiac mitochondrial functional capacity and cellular energy metabolism. However, the regulation of PGC-1{alpha} in cardiac Ca{sup 2+} signaling has not been fully elucidated. To address this issue, we combined confocal line-scan imaging with off-line imaging processing to characterize calcium signaling in cultured adult rat ventricular myocytes expressing PGC-1{alpha} via adenoviral transduction. Our data shows that overexpressing PGC-1{alpha} improved myocyte contractility without increasing the amplitude of Ca{sup 2+} transients, suggesting that myofilament sensitivity to Ca{sup 2+} increased. Interestingly, the decay kinetics of global Ca{sup 2+} transients and Ca{sup 2+} waves accelerated in PGC-1{alpha}-expressing cells, but the decay rate of caffeine-elicited Ca{sup 2+} transients showed no significant change. This suggests that sarcoplasmic reticulum (SR) Ca{sup 2+}-ATPase (SERCA2a), but not Na{sup +}/Ca{sup 2+} exchange (NCX) contribute to PGC-1{alpha}-induced cytosolic Ca{sup 2+} clearance. Furthermore, PGC-1{alpha} induced the expression of SERCA2a in cultured cardiac myocytes. Importantly, overexpressing PGC-1{alpha} did not disturb cardiac Ca{sup 2+} homeostasis, because SR Ca{sup 2+} load and the propensity for Ca{sup 2+} waves remained unchanged. These data suggest that PGC-1{alpha} can ameliorate cardiac Ca{sup 2+} cycling and improve cardiac work output in response to physiological stress. Unraveling the PGC-1{alpha}-calcium handing pathway sheds new light on the role of PGC-1{alpha} in the therapy of cardiac diseases.

60 APPLIED LIFE SCIENCES↗

High-harmonic spectroscopy of transient two-center interference calculated with time-dependent density-functional theory

We demonstrate high-harmonic spectroscopy in many-electron molecules using time-dependent density-functional theory. We show that a weak attosecond-pulse-train ionization seed that is properly synchronized with the strong driving mid-infrared laser field can produce experimentally relevant high-harmonic generation (HHG) signals, from which we extract both the spectral amplitude and the target-specific phase (group delay). We also show that further processing of the HHG signal can be used to achieve molecular-frame resolution, i.e., to resolve the contributions from rescattering on different sides of an oriented molecule. In this framework, we investigate transient two-center interference in CO2 and OCS, and how subcycle polarization effects shape the oriented/aligned angle-resolved spectra.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rare Higgs Processes at CMS and Precision Timing Detector Studies for HL-LHC CMS Upgrade

This thesis describes the search for two rare Higgs processes. The first analysis describes the CMS Run 2 search for $H$ $\rightarrow$ $\mu$$\mu$ decays, with 137.3 fb$^{-1}$ of data at $\sqrt{s}$ = 13 TeV. The analysis targeted four different Higgs production modes: the gluon fusion (ggH), the vector boson fusion (VBF), the Higgs-strahlung process (VH), and the production in association with a pair of top quarks (ttH). Each category used a dedicated machine learning based classifier to separate the signal from the background processes. A combined fit from all these categories saw a slight excess in the data corresponding to 3.0 standard deviations at $M$$_{H}$ = 125.38 GeV, and gave the first evidence for the Higgs boson decay to second-generation fermions. The best-fit signal strength and the corresponding 68% CL interval was found to be +0.17?????? = 1.19 $_{-0.39}^{+0.41}$ (stat)$_{-0.16}^{+0.17}$(syst) at $M$$_{H}$ = 125.38 GeV. The second analysis describes the CMS Run 2 search for 𝐻𝐻 → 𝑏𝑏𝑏𝑏 with highly boosted Higgs bosons. This analysis used a dedicated jet identification algorithm based on graph neural networks (ParticleNet) to identify boosted H→ bb jets. This search targeted the gluon fusion and the vector boson fusion HH production modes, and put constraints on the allowed values of the various Higgs couplings as: 𝜅𝜆 ∈ [−9.9, 16.9] when 𝜅𝑉 = 1, 𝜅2𝑉 = 1; 𝜅𝑉 ∈ [−1.17, −0.79] ∪ [0.81, 1.18] when 𝜅𝜆 = 1, 𝜅2𝑉 = 1; 𝜅2𝑉 ∈ [0.62, 1.41] when 𝜅𝜆 = 1, 𝜅𝑉 = 1. A scenario with 𝜅2𝑉 = 0 was excluded with a significance of 6.3 standard deviations for the first time, when other H couplings are fixed to their SM values. The combined observed (expected) 95% upper limit on the HH production cross section was found to be 9.9 (5.1) × SM. Finally, this thesis also discusses the planned MIP Timing Detector (MTD) upgrade for CMS at the HL-LHC. The MTD will be a time-of-flight (TOF) detector, designed to provide a precision timing information for charged particles using SiPMs + LYSO scintillating crystals, with a time resolution of ∼30 ps. This thesis describes several R&D tests that have been performed for characterizing the sensor properties (time resolution, light yield, etc.) and optimizing the sensor design geometry. This thesis also contains a description of mock test setups for cooling the sensors, since it is known to be an effective way of mitigating the increased dark current rates in the sensors due to radiation damage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Electrochemical Investigation of Moisture Byproducts in Molten Calcium Chloride

Residual water in molten CaCl 2 reacts to form different byproducts, such as HCl, which can impact the corrosivity of the salt and efficiency of electrochemical operations, such as electrolytic oxide reduction and electrorefining. The ability to detect and quantify these byproducts electrochemically can provide feedback on the efficacy of vacuum drying and other purification methods, as well as the impact of these byproducts on process operations. An electrochemical signal’s association with the production of H 2 is verified and characterized using cyclic voltammetry (CV) and residual gas analysis. CV estimated a 2-electron exchange process associated with H 2 production. CV detected trace quantities of an oxidized species containing hydrogen in the salt on the order of 10 ppm. Different salt handling methods were compared for their impact on the hydrogen electrochemical signal. It was found that 30 min of exposure of CaCl 2 in a beaker to low-humidity air (<20%) had minimal impact on the H 2 production signal.

Electrochemistry↗

PLAT domain protein 1 (PLAT1/PLAFP) binds to the Arabidopsis thaliana plasma membrane and inserts a lipid

Robust agricultural yields depend on the plant's ability to fix carbon amid variable environmental conditions. Over seasonal and diurnal cycles, the plant must constantly adjust its metabolism according to available resources or external stressors. The metabolic changes that a plant undergoes in response to stress are well understood, but the long-distance signaling mechanisms that facilitate communication throughout the plant are less studied. The phloem is considered the predominant conduit for the bidirectional transport of these signals in the form of metabolites, nucleic acids, proteins, and lipids. Lipid trafficking through the phloem in particular attracted our attention due to its reliance on soluble lipid-binding proteins (LBP) that generate and solubilize otherwise membrane-associated lipids. The Phloem Lipid-Associated Family Protein (PLAFP) from Arabidopsis thaliana is generated in response to abiotic stress as is its lipid-ligand phosphatidic acid (PA). PLAFP is proposed to transport PA through the phloem in response to drought stress. To understand the interactions between PLAFP and PA, nearly 100 independent systems comprised of the protein and one PA, or a plasma membrane containing varying amounts of PA, were simulated using atomistic classical molecular dynamics methods. In these simulations, PLAFP is found to bind to plant plasma membrane models independent of the PA concentration. When bound to the membrane, PLAFP adopts a binding pose where W41 and R82 penetrate the membrane surface and anchor PLAFP. This triggers a separation of the two loop regions containing W41 and R82. Subsequent simulations indicate that PA insert into the β -sandwich of PLAFP, driven by interactions with multiple amino acids besides the W41 and R82 identified during the insertion process. Finally, fine-tuning the protein-membrane and protein-PA interface by mutating a selection of these amino acids may facilitate engineering plant signaling processes by modulating the binding response.

59 BASIC BIOLOGICAL SCIENCES↗

RECOVERING A SHORT TIMESCALE SIGNAL FROM A PAIR OF LONG-DELAY VISARS

We introduce the benefits of analyzing VISAR data in the Fourier domain, particularly for recovering the short time scale signal component. In particular, by combining data from two VISARS having different long delays, we effectively reproduce the short time resolution ability of a short delay while retaining the superior sensitivity to absolute velocity of a long delay. Two different delays are generally desired, not only to untangle integer fringe skips, but to circumvent the fact that a single VISAR cannot record signal components of frequencies periodic with its reciprocal delay. Combining two different delays solves this. We treat the VISARs as linear filters and process and combine the signals in the Fourier domain with a direct equation, without any iteration of time-retarded equations. The technique is demonstrated with a numerical simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Qualification of the ITER CS Quench Detection System using Numerical Modeling

Abstract The ITER Central Solenoid (CS) magnet needs to be protected against overheating of the conductor in the event of the occurrence of a normal zone (NZ). Due to a large amount of stored energy and slow NZ propagation, the NZ needs to be detected and the switchyard needs to open the breakers within 2 s after detection of the NZ. The CS will be discharged on a dump resistor with a time constant of 7.5 s. During operation of the CS and its interaction with the poloidal field (PF) coils and plasma current, the CS experiences large inductive voltages from multiple sources, including nonlinear signals from eddy currents in the vacuum vessel and plasma current variation, that make the task of detecting the resistive signal even more difficult. This inductive voltage needs to be cancelled by quench detection (QD) hardware (e.g., bridges, converters, filters, processors) and appropriate processing of the QD signals to reliably detect NZ initiation and propagation. Two redundant schemes are proposed as the baseline for the CS QD System: 1) A scheme with Regular Voltage Taps (RVT) from triads of Double Pancakes (DP) supplemented by Central Difference Averaging (CDA) and by digital suppression of the inductive voltage from all active coils (the CS and PF coils). Voltage taps are taken from helium outlets at the CS outer diameter. 2)A scheme with Cowound Voltage Taps (CVT) taken from cowound wires routed from the helium inlet at the CS inner diameter. Summary of results of the numerical modeling of the performance of both baseline CS QD systems is presented in this paper. Index Terms Quench detection, Central Solenoid, ITER

Martovetsky, Nicolai N↗

Integrated Geophysical Measurements for Bioremediation Monitoring: Combining Spectral Induced Polarization, Nuclear Magnetic Resonance and Magnetic Methods

This documents contains the final report for the project "Integrated Geophysical Measurements for Bioremediation Monitoring: Combining Spectral Induced Polarization, Nuclear Magnetic Resonance and Magnetic Methods" (DE-SC0007049) Executive Summary: Our research aimed to develop borehole measurement techniques capable of monitoring subsurface processes, such as changes in pore geometry and iron/sulfur geochemistry, associated with remediation of heavy metals and radionuclides. Previous work has demonstrated that geophysical method spectral induced polarization (SIP) can be used to assess subsurface contaminant remediation; however, SIP signals can be generated from multiple sources limiting their interpretation value. Integrating multiple geophysical methods, such as nuclear magnetic resonance (NMR) and magnetic susceptibility (MS), with SIP, could reduce the ambiguity of interpretation that might result from a single method. Our research efforts entails combining measurements from these methods, each sensitive to different mineral forms and/or mineral-fluid interfaces, providing better constraints on changes in subsurface biogeochemical processes and pore geometries significantly improving our understanding of processes impacting contaminant remediation. The Rifle Integrated Field Research Challenge (IFRC) site was used as a test location for our measurements. The Rifle IFRC site is located at a former uranium ore-processing facility in Rifle, Colorado. Leachate from spent mill tailings has resulted in residual uranium contamination of both groundwater and sediments within the local aquifer. Studies at the site include an ongoing acetate amendment strategy, native microbial populations are stimulated by introduction of carbon intended to alter redox conditions and immobilize uranium. To test the geophysical methods in the field, NMR and MS logging measurements were collected before, during, and after acetate amendment. Next, laboratory NMR, MS, and SIP measurements were collected on columns of Rifle sediments during acetate amendment. The laboratory experiments were designed to simulate the field experiments; changes in geophysical signals were expected to correlate with changes in redox conditions and iron speciation. Field MS logging measurements revealed vertically stratified magnetic mineralization, likely the result of detrital magnetic fraction within the bulk alluvium. Little to no change was observed in the MS data suggesting negligible production of magnetic phases (e.g. magnetite, pyrrhotite) as a result of sulfidogenesis. Borehole NMR measurements contained high levels of noise contamination requiring significant signal processing, and analysis suggests that any changes may be difficult to differentiate from simultaneous changes in water content. Laboratory MS and NMR measurements remained relatively stable throughout the course of the acetate amendment experiment, consistent with field measurements. However, SIP measurements changed during the acetate amendment associated with the formation of iron-sulfide mineral phases; a finding that is consistent with chemical analysis of the solid phase materials in the columns.

54 ENVIRONMENTAL SCIENCES↗

A high performance cost-effective digital complex correlator for an X-band polarimetry survey

The detailed knowledge of the Milky Way radio emission is important to characterize galactic foregrounds masking extragalactic and cosmological signals. The update of the global sky models describing radio emissions over a very large spectral band requires high sensitivity experiments capable of observing large sky areas with long integration times. Here, we present the design of a new 10 GHz (X-band) polarimeter digital backend to map the polarization components of the galactic synchrotron radiation field of the Northern Hemisphere sky. The design follows the digital processing trends in radio astronomy and implements a large bandwidth (1 GHz) digital complex cross-correlator to extract the Stokes parameters of the incoming synchrotron radiation field. The hardware constraints cover the implemented VLSI hardware description language code and the preliminary results. The implementation is based on the simultaneous digitized acquisition of the Cartesian components of the two linear receiver polarization channels. The design strategy involves a double data rate acquisition of the ADC interleaved parallel bus, and field programmable gate array device programming at the register transfer mode. The digital core of the back-end is capable of processing 32 Gbps and is built around an Altera field programmable gate array clocked at 250 MHz, 1 GSps analog to digital converters and a clock generator. The control of the field programmable gate array internal signal delays and a convenient use of its phase locked loops provide the timing requirements to achieve the target bandwidths and sensitivity. This solution is convenient for radio astronomy experiments requiring large bandwidth, high functionality, high volume availability and low cost. Of particular interest, this correlator was developed for the Galactic Emission Mapping project and is suitable for large sky area polarization continuum surveys. The solutions may also be adapted to be used at signal processing subsystem levels for large projects like the square kilometer array testbeds.

79 ASTRONOMY AND ASTROPHYSICS↗

R&D studies of the ATLAS LAr calorimeter readout electronics for super-LHC

The ATLAS Liquid Argon (LAr) calorimeters are high precision, high sensitivity and high granularity detectors. A total of 182,468 signals are digitized and processed real-time on detector, to provide energy and time deposited in each detector element at every occurrence of the L1-trigger. The current readout electronics will need to be upgraded to sustain the higher radiation levels expected with the increase of a factor 10 in luminosity at the LHC in the years {approx}2017. A completely innovative readout scheme is being developed. The front-end readout will send out data continuously at each bunch crossing through high speed radiation resistant optical links, the data will be processed real-time with the possibility of implementing trigger algorithms. This article is an overview of the R&D activities and architectural studies the ATLAS LAr Calorimeter Group is developing: front-end analog and mixed-signal ASIC design, radiation resistance optical-links in SOS, high-speed back-end processing units based on FPGA architectures and power supply distribution schemes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Residual Optically Stimulated Luminescent (OSL) Signals for Al 2 O 3 :C and a Readout System with Reproducible Partial Signal Clearance

Optically stimulated luminescent dosimeters (OSLDs) are devices that, when stimulated with light, emit light in proportion to the integrated ionizing radiation dose. The stimulation of OSL material results in the loss of a small fraction of signal stored within the dosimetric traps. Previous studies have investigated the signal loss due to readout stimulation, and the optical annealing of OSLDs. This study builds on former research by examining the behavior of OSL signal after annealing, exploring the functionality of a previously developed signal loss model, and comparing uncertainties for dosimeters reused with or without annealing. For a completely annealed dosimeter, the minimum signal level was 56 ± 8 counts, and readings followed a Gaussian distribution. For dosimeters above this signal level, the fractional signal loss due to the reading process has a linear relationship with the calculated signal. At low signal levels (below 20,000 counts), in this OSLD system,calculated signal percent errors increase significantly but otherwise are on average 0.72 ± 0.27%, 0.40 ± 0.19%, 0.33±0.12%, and 0.24±0.07% for 30, 75, 150, and 300 readings. Theoretical calculations of uncertainties showed that annealing before reusing dosimeters allows for dose errors below 1% with as few as 30 readings. Reusing dosimeters multiple times increases the dose errors especially with low numbers of readouts, so theoretically around 300 readings would be necessary to achieve errors around 1% or below in most scenarios. Note that these dose errors do not include the error associated with the signal-to-dose conversion factor.

61 RADIATION PROTECTION AND DOSIMETRY↗

Edge-computing with enhanced standoff sensors

A system senses analytes through one or more sensors that detect or measure a physical characteristic. The one or more sensor generate a spectroscopic-data signal corresponding to the detection. An edge device communicatively couples the one or more sensors that communicatively couples a wide-area network coupling a cloud service. The edge device includes a data acquisition device that receives spectroscopic data signals from the one or more sensor and a processor that processes the spectroscopic-data signals to identify an analyte. The edge device also includes a transceiver that transmits data identifying the analytes to the cloud service.

Passian, Ali↗