At least 1,639 records · Page 91

Data Driven Smart Proxy for CFD Application of Big Data Analytics & Machine Learning in Computational Fluid Dynamics, Part Three: Model Building at the Layer Level

To ensure the usefulness of simulation technologies in practice, their credibility needs to be established with Uncertainty Quantification (UQ) methods. In this project smart proxy is introduced to significantly reduce the computational cost of conducting large number of multiphase CFD simulations. Smart proxy for CFD models are developed using pattern recognition capabilities of Artificial Intelligence (AI), Machine Learning (LM) and Data Mining (DM) technologies. Several CFD simulation runs with different inlet air velocities for a rectangular fluidized bed are used to create a smart CFD proxy that is capable of replicating the CFD results for a wide variety of inlet velocities. The smart CFD proxy is validated with blind CFD runs (CFD runs that have not played any role during the development [training, calibration and validation] of the smart CFD proxy). In our earlier work, CFD data was used to train ANN at the cell level. That is an ANN was trained for each computational cell used in the CFD simulations. In the present work, the ANN is constructed and trained based on cross sectional area average of each variable, such as pressure, velocities and volume fraction (Layer Level). This leads to improvements in the training time at the expense of less spatial resolution. The resulting trained ANN provides spatially average value of parameters of interest, along the length of the fluidized bed. Upon completion of this project, UQ studies that rely on hundreds or thousands of smart CFD proxy runs can be accomplished in minutes. Following figure demonstrates a validation example (blind CFD run) showing the results from the MFiX and the smart CFD proxy for pressure drop across a fluidized bed at time-step of 1400 (the layer number corresponds to the vertical location in the bed).

97 MATHEMATICS AND COMPUTING↗

MPACT Development Activities at University of Michigan

This report documents the efforts of general development tasks in MPACT performed primarily at the University of Michigan during FY17. These tasks included: 1. Unstructured CMFD - The unstructured CMFD supports the RIA and BWR challenge problems. It allows MPACT to simulate mixed lattice cores (e.g. 8x8 next to 9x9). This design feature is common to operating BWRs and also the SPERT experiments being used to validate VERA-CS for RIA. 2. Higher order spatial sources for MOC - The higher order sources are for improving the overall performance of MPACT. Higher order spatial sources in MOC provide accurate solutions with potentially significantly fewer mesh regions, thus speeding up every calculation. This method is also particularly important for BWRs. 3. Improving fine source region visualization - The improvement of the visualization of the flat source region mesh in MPACT is to support users and communication of models and results from MPACT. VERAView provides visualization of pin-wise information, however MPACT resolves the spatial solution to intra pin level. The capability provided here will let users visualize the full model geometry and components of the solution at the highest spatial resolution available from MPACT. 4. Automated spatial decomposition - The automated spatial decomposition removes the burden from the user to know how to spatially decompose the model for MPACT; a task that has been rather tricky in the past. Instead the user may give some number of processors that is a multiple of the axial mesh and MPACT will determine a nearly optimal decomposition that gives better load balance than most decompositions used currently. 5. Optimal relaxation factors for feedback - The development of optimal relaxation factor is to improve the stability and robustness of problems with feedback. Presently the default feedback values are 0.5, which may or may not be optimal. Without relaxation the fixed point iteration that is currently used is known to be unstable for large problems. The optimal relaxation factors are derived by utilizing a previous Fourier analysis. From the original milestone there was a scope change where the work on the Intel MIC was deferred for work on the automated spatial decomposition.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

LGAD-Based Silicon Sensors for 4D Detectors

Low-Gain Avalanche Diodes (LGAD) are a class of silicon sensors developed for the fast detection of Minimum Ionizing Particles (MIPs). The development was motivated by the need of resolving piled-up tracks of charged particles emerging from several vertexes originating from the same bunch-crossing in High-Energy Physics (HEP) collider experiments, which, however, are separated not only in space but also in time by a few tens of picoseconds. Built on thin silicon substrates and featuring an internal moderate gain, they provide fast signals for excellent timing performance, which are therefore useful to distinguish the different tracks. Unfortunately, this comes at the price of poor spatial resolution. To overcome this limitation, other families of LGAD-based silicon sensors which can deliver in the same substrate both excellent timing and spatial information are under development. Such devices are, to name a few, capacitively coupled LGADs (AC-LGAD), deep-junction LGADs (DJ-LGAD) and trench-isolated LGADs (TI-LGADs). These devices can be fabricated by even small-scale research-focused clean rooms for faster development within the scientific community. However, to scale up production, efforts towards integrating these sensor concepts in CMOS substrates, with the obvious advantage of the possibility of integrating part of the read-out electronics in the same substrate, have begun.

spatial resolution↗

Plasma potential mapping of high power impulse magnetron sputtering discharges

Pulsed emissive probe techniques have been used to determine the plasma potential distribution of high power impulse magnetron sputtering (HiPIMS) discharges. An unbalanced magnetron with a niobium target in argon was investigated for pulse length of 100 μs at a pulse repetition rate of 100 Hz, giving a peak current of 170 A. The probe data were taken with a time resolution of 20 ns and a spatial resolution of 1 mm. It is shown that the local plasma potential varies greatly in space and time. The lowest potential was found over the target’s racetrack, gradually reaching anode potential (ground) several centimeters away from the target. The magnetic pre-sheath exhibits a funnel-shaped plasma potential resulting in an electric field which accelerates ions toward the racetrack. In certain regions and times, the potential exhibits weak local maxima which allow for ion acceleration to the substrate. Knowledge of the local E and static B fields lets us derive the electrons’ E×B drift velocity, which is about 105 m/s and shows structures in space and time.

36 MATERIALS SCIENCE↗

SU-F-T-559: High-Resolution Scintillating Fiber Array for In-Vivo Real-Time SRS and SBRT Patient QA

Purpose: A high-resolution scintillating fiber detector was built for in-vivo real-time patient specific quality assurance (QA). The detector is designed for stereotactic body radiotherapy (SBRT) and stereotactic radiosurgery (SRS) to monitor treatment delivery and detect real-time deviations from planned dose to increase patient safety and treatment accuracy. Methods: The detector consists of two high-density scintillating fiber arrays layered to form an X-Y grid which can be attached to the accessory tray of a medical linac for SBRT and cone SRS treatment QA. Fiber arrays consist of 128 scintillating fibers embedded within a precision-machined, high-transmission polymer substrate with 0.8mm pitch. The fibers are coupled on both ends to high-sensitivity photodetectors and the output is recorded through a high-speed analog-to-digital converter to capture the linac pulse sequence as treatment delivery progresses. The detector has a software controlled 360 degree rotational system to capture angular beam projections for high-resolution beam profile reconstruction. Results: The detector was validated using SRS cone sizes from 6mm to 34mm and MLC defined field sizes from 5×5mm2 to 100×100mm2. The detector output response is linear with dose and is dose rate independent. Each field can be reconstructed accurately with a spatial resolution of 0.8mm and the current beam output is displayed every 50msec. Dosimetric errors of 1% with respect to the treatment plan can be identified and clinically significant deviations from the expected treatment can be displayed in real-time to alert the therapists. Conclusion: The high resolution detector is capable of reconstructing beam profiles in real-time with submillimeter resolution and 1% dose resolution. This system has the ability to project in-vivo both spatial and dosimetric errors during SBRT and SRS treatments when only a non-clinically significant fraction of the intended dose was delivered. The device has the potential to establish new standards for in-vivo patient specific QA.

60 APPLIED LIFE SCIENCES↗

Two-dimensional Detector for High Resolution Soft X-ray Imaging

A new two-dimensional (2D) detector for detecting soft X-ray (SX) images was developed. The detector has a scintillator plate to convert a SX image into a visible (VI) one, and a relay optics to magnify and detect the converted VI image. In advance of the fabrication of the detector, quantum efficiencies of scintillators were investigated. As a result, a Ce:LYSO single crystal on which Zr thin film was deposited was used as an image conversion plate. The spatial resolution of fabricated detector is 3.0 {mu}m, and the wavelength range which the detector has sensitivity is 30-6 nm region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Deep Neural Network High Spatiotemporal Resolution Precipitation Estimation (Deep-STEP) Using Passive Microwave and Infrared Data

Recent developments in “headline-making” deep neural networks (DNNs), specifically convolutional neural networks (CNNs), along with advancements in computational power, open great opportunities to integrate massive amounts of real-time observations to characterize spatiotemporal structures of surface precipitation. This study aims to develop a CNN algorithm, named Deep Neural Network High Spatiotemporal Resolution Precipitation Estimation (Deep-STEP), that ingests direct satellite passive microwave (PMW) brightness temperatures (Tbs) at emission and scattering frequencies combined with infrared (IR) Tbs from geostationary satellites and surface information to automatically extract geospatial features related to the precipitable clouds. These features allow the end-to-end Deep-STEP algorithm to instantaneously map surface precipitation intensities with a spatial resolution of 4 km. The main advantages of Deep-STEP, as compared to current state-of-the-art techniques, are 1) it learns and estimates complex precipitation systems directly from raw measurements in near–real time, 2) it uses the automatic spatial neighborhood feature extraction approach, and 3) it fuses coarse-resolution PMW footprints with IR images to reliably retrieve surface precipitation at a high spatial resolution. We anticipate our proposed DNN algorithm to be a starting point for more sophisticated and efficient precipitation retrieval systems in terms of accuracy, fine spatial pattern detection skills, and computational costs.

54 ENVIRONMENTAL SCIENCES↗

High-resolution spectroscopy for Doppler-broadening ion temperature measurements of implosions at the National Ignition Facility

Future implosion experiments at the national ignition facility (NIF) will endeavor to simultaneously measure electron and ion temperatures with temporal and spatial resolution in order to explore non-equilibrium temperature distributions and their relaxation toward equilibrium. In anticipation of these experiments, and with understanding of the constraints of the NIF facility environment, we have explored the use of Doppler broadening of mid-Z dopant emission lines, such as krypton He-{alpha} at 13 keV, as a diagnostic of time- and potentially space-resolved ion temperature. We have investigated a number of options analytically and with numerical raytracing, and we have identified several promising candidate spectrometer designs that meet the expected requirements of spectral and temporal resolution and data signal-to-noise ratio for gas-filled exploding pusher implosions, while providing maximum flexibility for use on a variety of experiments that potentially include burning plasma.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Confocal shift interferometry of coherent emission from trapped dipolar excitons

We introduce a confocal shift-interferometer based on optical fibers. The presented spectroscopy allows measuring coherence maps of luminescent samples with a high spatial resolution even at cryogenic temperatures. We apply the spectroscopy onto electrostatically trapped, dipolar excitons in a semiconductor double quantum well. We find that the measured spatial coherence length of the excitonic emission coincides with the point spread function of the confocal setup. The results are consistent with a temporal coherence of the excitonic emission down to temperatures of 250 mK.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Shield: comparing gas and star formation in low-mass galaxies

We analyze the relationships between atomic, neutral hydrogen (H i) and star formation (SF) in the 12 low-mass SHIELD galaxies. We compare high spectral (∼0.82 km s{sup −1} ch{sup −1}) and spatial resolution (physical resolutions of 160–640 pc) H i imaging from the VLA with Hα and far-ultraviolet imaging. We quantify the degree of co-spatiality between star-forming regions and regions of high H i column densities. We calculate the global star formation efficiencies (SFE; Σ{sub SFR} / Σ{sub HI}) and examine the relationships among the SFE and H i mass, H i column density, and star formation rate (SFR). The systems are consuming their cold neutral gas on timescales of order a few gigayears. While we derive an index for the Kennicutt–Schmidt relation of N ≈ 0.68 ± 0.04 for the SHIELD sample as a whole, the values of N vary considerably from system to system. By supplementing SHIELD results with those from other surveys, we find that H i mass and UV-based SFR are strongly correlated over five orders of magnitude. Identification of patterns within the SHIELD sample allows us to bin the galaxies into three general categories: (1) mainly co-spatial H i and SF regions, found in systems with the highest peak H i column densities and highest total H i masses; (2) moderately correlated H i and SF regions, found in systems with moderate H i column densities; and (3) obvious offsets between H i and SF peaks, found in systems with the lowest total H i masses. SF in these galaxies is dominated by stochasticity and random fluctuations in their ISM.

79 ASTRONOMY AND ASTROPHYSICS↗

DENSITY WAVES EXCITED BY LOW-MASS PLANETS IN PROTOPLANETARY DISKS. II. HIGH-RESOLUTION SIMULATIONS OF THE NONLINEAR REGIME

We investigate numerically the propagation of density waves excited by a low-mass planet in a protoplanetary disk in the nonlinear regime, using two-dimensional local shearing box simulations with the grid-based code Athena at high spatial resolution (256 grid points per scale height h). The nonlinear evolution results in the wave steepening into a shock, causing damping and angular momentum transfer to the disk. On long timescales this leads to spatial redistribution of the disk density, causing migration feedback and potentially resulting in gap opening. Previous numerical studies concentrated on exploring these secondary phenomena as probes of the nonlinear wave evolution. Here we focus on exploring the evolution of the basic wave properties, such as its density profile evolution, shock formation, and post-shock wave behavior, and provide comparison with analytical theory. The generation of potential vorticity at the shock is computed analytically and is subsequently verified by simulations and used to pinpoint the shock location. We confirm the theoretical relation between the shocking length and the planet mass (including the effect of the equation of state), and the post-shock decay of the angular momentum flux carried by the wave. The post-shock evolution of the wave profile is explored, and we quantitatively confirm its convergence to the theoretically expected N-wave shape. The accuracy of various numerical algorithms used to compute the nonlinear wave evolution is also investigated: we find that higher order spatial reconstruction and high resolution are crucial for capturing the shock formation correctly.

79 ASTRONOMY AND ASTROPHYSICS↗

Snapshot of a Reaction Intermediate: Analysis of Benzoylformate Decarboxylase in Complex with a Benzoylphosphonate Inhibitor

Benzoylformate decarboxylase (BFDC) is a thiamin diphosphate- (ThDP-) dependent enzyme acting on aromatic substrates. In addition to its metabolic role in the mandelate pathway, BFDC shows broad substrate specificity coupled with tight stereo control in the carbon-carbon bond-forming reverse reaction, making it a useful biocatalyst for the production of chiral-hydroxy ketones. The reaction of methyl benzoylphosphonate (MBP), an analogue of the natural substrate benzoylformate, with BFDC results in the formation of a stable analogue (C2{alpha}-phosphonomandelyl-ThDP) of the covalent ThDP-substrate adduct C2{alpha}-mandelyl-ThDP. Formation of the stable adduct is confirmed both by formation of a circular dichroism band characteristic of the 1',4'-iminopyrimidine tautomeric form of ThDP (commonly observed when ThDP forms tetrahedral complexes with its substrates) and by high-resolution mass spectrometry of the reaction mixture. In addition, the structure of BFDC with the MBP inhibitor was solved by X-ray crystallography to a spatial resolution of 1.37 {angstrom} (PDB ID 3FSJ). The electron density clearly shows formation of a tetrahedral adduct between the C2 atom of ThDP and the carbonyl carbon atom of the MBP. This adduct resembles the intermediate from the penultimate step of the carboligation reaction between benzaldehyde and acetaldehyde. The combination of real-time kinetic information via stopped-flow circular dichroism with steady-state data from equilibrium circular dichroism measurements and X-ray crystallography reveals details of the first step of the reaction catalyzed by BFDC. The MBP-ThDP adduct on BFDC is compared to the recently solved structure of the same adduct on benzaldehyde lyase, another ThDP-dependent enzyme capable of catalyzing aldehyde condensation with high stereospecificity.

59 BASIC BIOLOGICAL SCIENCES↗

HERSCHEL SPECTROSCOPIC OBSERVATIONS OF LITTLE THINGS DWARF GALAXIES

We present far-infrared (FIR) spectral line observations of five galaxies from the Little Things sample: DDO 69, DDO 70, DDO 75, DDO 155, and WLM. While most studies of dwarfs focus on bright systems or starbursts due to observational constraints, our data extend the observed parameter space into the regime of low surface brightness dwarf galaxies with low metallicities and moderate star formation rates. Our targets were observed with Herschel at the [C ii] 158 μm, [O i] 63 μm, [O iii] 88 μm, and [N ii] 122 μm emission lines using the PACS Spectrometer. These high-resolution maps allow us for the first time to study the FIR properties of these systems on the scales of larger star-forming complexes. The spatial resolution in our maps, in combination with star formation tracers, allows us to identify separate photodissociation regions (PDRs) in some of the regions we observed. Our systems have widespread [C ii] emission that is bright relative to continuum, averaging near 0.5% of the total infrared (TIR) budget—higher than in solar-metallicity galaxies of other types. [N ii] is weak, suggesting that the [C ii] emission in our galaxies comes mostly from PDRs instead of the diffuse ionized interstellar medium (ISM). These systems exhibit efficient cooling at low dust temperatures, as shown by ([O i]+[C ii])/TIR in relation to 60 μm/100 μm, and low [O i]/[C ii] ratios which indicate that [C ii] is the dominant coolant of the ISM. We observe [O iii]/[C ii] ratios in our galaxies that are lower than those published for other dwarfs, but similar to levels noted in spirals.

79 ASTRONOMY AND ASTROPHYSICS↗

EXPLOSIVE EVENTS ASSOCIATED WITH A SURGE

The solar atmosphere contains a wide variety of small-scale transient features. Here, we explore the interrelation between some of them such as surges, explosive events, and blinkers via simultaneous spectral and imaging data taken with the TRACE imager, the SUMER and Coronal Diagnostics Spectrometer (CDS) on board SOHO, and Swedish Vacuum Solar Telescope La Palma. The features were observed in spectral lines with formation temperatures from 10,000 K to 1 MK and with the TRACE Fe IX/X 171 A filter. The H{alpha} filtergrams were taken in the wings of the H{alpha} 6365 A line at {+-}700 mA and {+-}350 mA. The alignment of all data in both time and solar XY shows that SUMER line profiles, which are attributed to explosive events, are due to a surge phenomenon. The surge's up- and downflows, which often appear simultaneously, correspond to the blue- and redshifted emission of the transition region N V 1238.82 A and O V 629.77 A lines as well as radiance increases of the C I, S I, and S II and Si II chromospheric lines. Some parts of the surge are also visible in the TRACE 171 A images which could suggest heating to coronal temperatures. The surge is triggered, most probably, by one or more Elerman bombs which are best visible in H{alpha} {+-} 350 A but were also registered by TRACE Fe IX/X 171 A and correspond to a strong radiance increase in the CDS Mg IX 368.07 A line. With the present study, we demonstrate that the division of small-scale transient events into a number of different subgroups, for instance explosive events, blinkers, spicules, surges or just brightenings, is ambiguous, implying that the definition of a feature based only on either spectroscopic or imaging characteristics as well as insufficient spectral and spatial resolution can be incomplete.

99 GENERAL AND MISCELLANEOUS↗

SU-E-T-150: Brachytherapy QA Employing a High Resolution Liquid Filled Ionisation Chamber Array: Initial Experience and Limitations

Purpose: Verifying a complex 3D brachytherapy dose distribution by measurement is non-trivial. Ideally a photon detector array should be independent of energy and angle, have high spatial resolution and be robust for routine clinical use. Methods: An iridium-192 source was used. A PMMA jig was constructed comprising an outer slab and a central insert with eight milled channels for 1.33mm (outer diameter) steel needles, see figure. All calculations were performed using an empty CT study reconstructing eight virtual needles (QA-CT), using the v2 source model (Elekta AG, Sweden). A high resolution liquid filled ionisation chamber array SRS1000, together with Verisoft software v6.0 (PTW Freiburg, Germany), was used to perform measurements of plans of increasing complexity to evaluate its suitability for device- and patient-specific QA. The dimension of backscatter material was investigated. The patient plan dwell time distribution was entered manually into the QA-CT and the dose distribution was calculated. Results: Our measurements indicate that the array is independent of energy and angle. The resulting measured dose values are linearly interpolated to 2025 values. Shifts of 1mm of the entire needle are readily detectable. Individual dwell position shifts (2.5mm) are also readily measurable. Moreover a dwell time increase of 1 second both in the edge and central region are detectable. Conclusion: The high resolution SRS1000 array is a powerful instrument for brachytherapy QA enabling 977 simultaneous measurements to be performed. Our measurements suggest 60mm of RW3 backscatter material upstream and downstream are sufficient. Local percentage difference analysis is useful for device based QA, normalized relative percentage difference is arguably better for patient specific QA. Automated transfer of patient plan dwell time distribution to the QA plan is required to enable a comprehensive patient QA study to be performed. Moreover the described measurement technique can be used for commissioning new brachytherapy applicators.

60 APPLIED LIFE SCIENCES↗

Performance characterization of a MVCT scanner using multislice thick, segmented cadmium tungstate-photodiode detectors

Purpose: Megavoltage computed tomography (MVCT) and megavoltage cone beam computed tomography (MVCBCT) can be used for visualizing anatomical structures prior to radiation therapy treatments to assist in patient setup and target localization. These systems are less susceptible to metal artifacts and provide better CT number linearity than conventional CT scanners. However, their contrast is limited by the properties of the megavoltage photons and the low detective quantum efficiency (DQE) of flat panel detector systems currently available. By using higher DQE, thick, segmented cadmium tungstate detectors, the authors can improve the low contrast detectability of a MVCT system. This in turn would permit greater soft tissue visualization for a given radiation dose, allowing MVCT to be used in more clinical situations. Methods: This article describes the evaluation of our prototype system that uses thick, segmented detectors. In order to create images using a dose that would be acceptable for day to day patient imaging, the authors evaluated their system using the low intensity bremsstrahlung component of a 6 MeV electron beam. The system was evaluated for its uniformity, high contrast resolution, low contrast detectability, signal to noise ratio, contrast to noise ratio, and CT number linearity. Results: The prototype system was found to have a high contrast spatial resolution of about 5 line pairs per cm, and to be able to visualize a 15 mm 1.5% contrast target with 2 cGy of radiation dose delivered. SNR{sup 2} vs radiation dose and mean pixel value vs electron density curves were linear. Conclusions: This prototype system shows a large improvement in low contrast detectability over current MVCBCT systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Proper orthogonal decomposition analysis of parallel twin jets measured using particle image velocimetry - 18685

The mixing of turbulent jets has been found in several locations of High Temperature Gas-cooled Reactors (HTGRs) including upper and lower plenums, where jets impinge into open space from coolant channels. In the present work, a parallel twin jets experimental facility was used to generate velocity field of mixing jets by means of Particle Image Velocimetry (PIV), which can be eventually used for validation of Computational Fluid Dynamics (CFD) simulations. The facility has two fixed parallel rectangular jet nozzles (5.8 mm in width, 87.8 mm in length) submerged in the middle of the water tank, which allows an assumption of free jet mixing. In order to compare the experimental data produced to existing data, Re = 4000 {approx} 5000 at the jet outlet was selected. In the past, several statistically meaningful data have been reported using Laser Doppler Velocimetry (LDV) and Hot Wire Anemometer (HWA), which can support Reynolds Averaged Navier-Stokes turbulent models. However, recent CFD simulations using Large Eddy Simulation (LES) require high resolution experimental data in time and space. Thus, in this study, in addition to statistically enough number of data sets for RANS models validation, high temporal and spatial resolution data were collected for the validation of LES calculations. In order to study the turbulent structure Reynolds decomposition and Proper Orthogonal Decomposition (POD) were applied to the data obtained. These decomposition analyses visualized multi-scale vortices and the transportation of eddies. In terms of twin jets structure, the present experimental data showed good agreement with other techniques for the important characteristic parameters including the length of the converging region and the location of the merging point. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Simultaneous High-Resolution 2-Dimensional Spatial and 1-Dimensional Picosecond Streaked X-ray Pinhole Imaging

A Kentech x-ray streak camera was run at the LLNL Compact Multipulse Terawatt (COMET) laser to record simultaneous space- and time-resolved measurements of picosecond laser-produced plasmas. Four different x-ray energy channels were monitored using broad-band filters to record the time history of Cu targets heated at irradiances of 10{sup 16} - 10{sup 19} W/cm{sup 2}. Through the Cu filter channel, a time-resolution below 3ps was obtained. Additionally, an array of 10 {micro}m diameter pinholes was placed in front of the camera to produce multiple time-resolved x-ray images on the photocathode and time-integrated images on the phosphor with 10 and 15 times magnification, respectively, with spatial resolution of <13 {micro}m.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗