Development of a distributed sensor that can simultaneously measure strain and temperature variations based on Rayleigh-backscattering optical fibers
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
The development of small modular reactors (SMRs) and Generation-IV advanced reactor designs represents a promising future for nuclear energy. These next-generation reactors can support new applications for nuclear energy like hydrogen production, industrial heat generation, and water desalination in addition to electricity generation. Furthermore, SMRs and advanced reactors enable load-following operations, offer improved passive safety features, support lengthened refueling cycles, and provide spent fuel management capabilities. To date, there are no SMRs operating or under construction in the United States, but commercial operation of the first integral Pressurized Water Reactor (iPWR) SMR is expected by the mid-2020's with Generation-IV advanced reactors to follow a decade or two later. To facilitate the development and deployment of SMRs and advanced reactors, key instrumentation and control (I and C) system challenges must be addressed and existing nuclear grade I and C sensors will need to be adapted or new sensors developed. For example, traditional measurement techniques and maintenance strategies used in the current generation of light water reactors (LWRs) will be challenged by the inherent design characteristics of the iPWR. For Generation-IV reactors, conventional I and C sensors will not withstand prolonged exposure to the harsh environmental conditions of advanced reactors (e.g. elevated temperatures, corrosive coolants, increased radiation). This paper discusses the challenges associated with making primary system process measurements in next-generation reactors and includes a summary of work performed to evaluate existing and emerging sensor technologies for these systems. As importantly, the paper presents the initial test results of a prototype temperature sensor developed by Analysis and Measurement Services Corporation (AMS) for use in SMRs and advanced reactors. (authors)
This paper reports the structural, optical and ethanol gas sensing properties of In{sub 2}O{sub 3} and 5% Dy{sup 3+}doped In{sub 2}O{sub 3} nanoparticles. The simple cost-effective hydrolysis assisted co-precipitation method was adopted. Synthesized samples were characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM) and UV-visible spectroscopy (UV-vis) techniques. XRD revealed that synthesized nanoparticles have cubic bixbyite phase. The lattice parameter, strain and crystallite size have been calculated by using the Williamson-Hall plots. UV-vis spectroscopy showed the red shift in the optical band gap due to Dy{sup 3+} doping in In{sub 2}O{sub 3} nanoparticles. For ethanol gas sensing properties, the nanoparticles were applied as thick film onto alumina substrate and tested at different operating temperatures. The results showed that the optimum operating temperature of both the gas sensors is 300°C. At optimum operating temperature, the response of In{sub 2}O{sub 3} and Dy{sup 3+}:In{sub 2}O{sub 3} gas sensor towards 250 ppm ethanol was found to be 9.65 and 37.80. The investigations revealed that the addition of Dy{sup 3+} as a dopant enhanced the sensing response of In{sub 2}O{sub 3} nanoparticles appreciably.
BiI 3 had been investigated for its unique properties as a layered compound semiconductor for many decades. However, despite the exceptional atomic, physical, and electronic properties of this material, good resolution gamma ray spectra had never been reported for BiI 3 . The shortcomings that previously prevented BiI 3 from reaching success as a gamma ray sensor were, through this project, identified and suppressed to unlock the performance of this promising compound. Included in this work were studies on a number of methods which have, for the first time, enabled BiI 3 to exhibit spectral performance rivaling many other candidate semiconductors for room temperature gamma ray sensors. New approaches to crystal growth were explored that allow BiI 3 spectrometers to be fabricated with up to 2.2% spectral resolution at 662 keV. Fundamental studies on trap states, dopant incorporation, and polarization were performed to enhance performance of this compound. Additionally, advanced detection techniques were applied to display the capabilities of high quality BiI 3 spectrometers. Overall, through this work, BiI 3 has been revealed as a potentially transformative material for nuclear security and radiation detection sciences.
This paper reports the acetone gas sensing properties of Cr{sub 2}O{sub 3} and 2% W{sup 6+} doped Cr{sub 2}O{sub 3} nanoparticles. The simple cost-effective hydrolysis assisted co-precipitation method was adopted. Synthesized samples were characterized by X-ray diffraction (XRD) and field emission scanning electron microscopy (FESEM) techniques. XRD revealed that synthesized nanoparticles have corundum structure. The lattice parameters have been calculated by Rietveld refinement; and strain and crystallite size have been calculated by using the Williamson-Hall plots. For acetone gas sensing properties, the nanoparticles were applied as thick film onto alumina substrate and tested at different operating temperatures. The results showed that the optimum operating temperature of both the gas sensors is 250°C. At optimum operating temperature, the response of Cr{sub 2}O{sub 3} and 2% W{sup 6+} doped Cr{sub 2}O{sub 3} gas sensor towards 100 ppm acetone was found to be 25.5 and 35.6 respectively. The investigations revealed that the addition of W{sup 6+} as a dopant enhanced the sensing response of Cr{sub 2}O{sub 3} nanoparticles appreciably.
In the 1960s, NASA embarked on a series of groundbreaking flight tests on the Saturn AS-203, aiming to understand the complex dynamics of propellants in the distinctive low-gravity lunar environment. These tests centered on venting experiments, subjecting cryogenic liquid hydrogen to conditions beneath its saturation pressure while accelerating the vehicle to manage the propellant's positioning. During these experiments, NASA meticulously scrutinized the propellant tank using a suite of instruments, including temperature and pressure sensors, as well as a camera placed internal to the liquid hydrogen tank. The outcomes provided anecdotal evidence revealing the phenomenon of boiling along the tank's walls and the intriguing formation of liquid globules and droplets in the ullage during the venting process. Notably, the substantial drop in liquid temperature during these tests suggests adiabatic cooling as liquid hydrogen evaporates. This evaporation leads to a cooling of the remaining hydrogen due to the heat it releases. This paper presents the outcomes of our initial analysis, wherein CFD models were used to simulate the observed boiling phenomena and the bulk movement of the liquid hydrogen propellant, both qualitatively and quantitatively. The implications of these findings may extend to mission and vehicle designers, providing invaluable insights for crafting more efficient and effective in-space propulsion systems utilizing cryogenic propellant including impacts to vehicle control systems. Understanding propellant behavior under these conditions may better inform GNC teams, ensuring more stable vehicle operations when utilizing cryogenic propellants. This includes essential considerations for cryogenic propellant transfer and storage systems, integral to NASA's forthcoming Artemis missions. While we recognize the challenges tied to CFD models, this study represents a step forward, highlighting current progress and signaling the potential for refining our predictive understanding in the future.
In the 1960s, NASA embarked on a series of groundbreaking flight tests on the Saturn AS-203, aiming to understand the complex dynamics of propellants in the distinctive low-gravity lunar environment. These tests centered on venting experiments, subjecting cryogenic liquid hydrogen to conditions beneath its saturation pressure while accelerating the vehicle to manage the propellant's positioning. During these experiments, NASA meticulously scrutinized the propellant tank using a suite of instruments, including temperature and pressure sensors, as well as a camera placed internal to the liquid hydrogen tank. The outcomes provided anecdotal evidence revealing the phenomenon of boiling along the tank's walls and the intriguing formation of liquid globules and droplets in the ullage during the venting process. Notably, the substantial drop in liquid temperature during these tests suggests adiabatic cooling as liquid hydrogen evaporates. This evaporation leads to a cooling of the remaining hydrogen due to the heat it releases. This paper presents the outcomes of our initial analysis, wherein CFD models were used to simulate the observed boiling phenomena and the bulk movement of the liquid hydrogen propellant, both qualitatively and quantitatively. The implications of these findings may extend to mission and vehicle designers, providing invaluable insights for crafting more efficient and effective in-space propulsion systems utilizing cryogenic propellant including impacts to vehicle control systems. Understanding propellant behavior under these conditions may better inform GNC teams, ensuring more stable vehicle operations when utilizing cryogenic propellants. This includes essential considerations for cryogenic propellant transfer and storage systems, integral to NASA's forthcoming Artemis missions. While we recognize the challenges tied to CFD models, this study represents a step forward, highlighting current progress and signaling the potential for refining our predictive understanding in the future.
Temperature gradients resulting from local electrochemical reactions, current distribution and geometry of gas flow channels in solid oxide fuel cells (SOFCs) create thermal stresses, localized thermophysical property gradients and uneven property evolution, contributing to SOFC degradation. This paper presents a new method to perform temperature measurements (up to 800°C) at high spatial resolutions to monitor the operation of SOFCs. Using femtosecond laser irradiation, distributed fiber sensors were hardened for high temperature environment applications. Distributed fiber sensors were embedded in interconnected plates using an additive manufacturing method to perform temperature measurements with 4-mm spatial resolution during the operation of a planar fuel cell. The measurement revealed the impact of various H 2 fuel concentrations and current loads have on temperature profiles of the SOFC tested. Temperature variation on the anode side was found to be less than 5°C, and 3°C on the cathode side. The measurements were compared to results from a multiphysics fuel cell performance model simulating similar conditions. These simulations predicted similar temperature gradients, indicating the experimental data obtained is reasonable. The model also predicts that the effect of the embedded sensor has on the local temperature will be minimal and that the gradient of temperature in the gas channels will be captured despite the separation between the sensor and the gas flow. Finally, the high spatial resolution data harnessed by these distributed fiber sensors provides experimental support for model-based design and optimization to improve the operational efficiency and longevity of solid oxide fuel cells and fuel cell assemblies.
This paper presents data on low-temperature measurements of silicon pressure sensors. It was found that both the piezoresistance coefficients and the charge-carrier mobility increase with decreasing temperature. For lightly doped semiconductor materials, the density of free charge carriers decreases with temperature and can freeze out eventually. However, the effect of carrier freeze-out can be minimized by increasing the impurity content to higher levels, at which the temperature dependency of piezoresistance coefficients is reduced. An impurity density of 1 x 10 to the 19th/cu cm was found to be optimal for cryogenic applications of pressure sensor dies.
Centerline loss, transient sink temperature and thermal conductivity design constantan considerations for thin foil copper-Gardon heat flux sensors
Transition metal dichalcogenides (TMDs) have attracted enormous attention in diverse research fields. Especially, gas sensors are considered in a promising application exploiting TMDs. However, the studies are confined to only major TMDs such as MoS 2 and WS 2 . Particularly, the chemoresistive sensing properties of two-dimensional (2D) NbS 2 have never been explored. For the first time, we report room temperature NO 2 sensing characteristics of 2D NbS 2 nanosheets and the sensing mechanisms using first-principles calculations based on density functional theory. The results demonstrate that the NbS 2 edges possessing different configurations depending on synthetic conditions differ in the sensing ability of the TMD nanosheets. Furthermore, this study not only broadens the potential of 2D NbS 2 for gas sensing applications, but also presents the important role of edge configuration of TMDs depending on synthetic conditions for further studies.
This paper presents on-going research in robotic inspection of space platforms. Three main areas of investigation are discussed: machine vision inspection techniques, an integrated sensor end-effector, and an orbital environment laboratory simulation. Machine vision inspection utilizes automatic comparison of new and reference images to detect on-orbit induced damage such as micrometeorite impacts. The cameras and lighting used for this inspection are housed in a multisensor end-effector, which also contains a suite of sensors for detection of temperature, gas leaks, proximity, and forces. To fully test all of these sensors, a realistic space platform mock-up has been created, complete with visual, temperature, and gas anomalies. Further, changing orbital lighting conditions are effectively mimicked by a robotic solar simulator. In the paper, each of these technology components will be discussed, and experimental results are provided.
This dataset was used to assess the potential of a Soil Deformation and Temperature Monitoring System developed and presented in the article named "Low-Power, Flexible Sensor Arrays with Solderless Board-to-Board Connectors for Monitoring Soil Deformation and Temperature" and published in Sensors. There are 21 comma-delimited data files (.csv). 14 files contain current measurements performed in a lab setting, enabling the electrical evaluation of the sensor probe. These files are generated by the Keithley DMM6500 multimeter, and list the measured supply current (first column) as a function of time (3rd column). Another set of 6 files is also acquired in lab experiments, but contain soil temperature an deformation measurements, enabling an assessment of the developed device's accuracy. In these files, the first column contains the time (UTC), followed by the sensor's battery voltage and temperature and acceleration values (X, Y, Z) in subsequent columns. The measurements were acquired every 5 seconds. Another .csv file contains field data in a similar format (time, temperature, acceleration) collected at the Teller road (mile 27) site near Nome, Alaska with one probe. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).
An aircraft prototype of the High-Resolution Interferometer Sounder (HIS) was flown over Tennessee and northern Alabama during summer 1986. The HIS temperature and dewpoint soundings were examined on two flight days to determine their error characteristics and utility in mesoscale analyses. Random errors were calculated from structure functions while total errors were obtained by pairing the HIS soundings with radiosonde-derived profiles. Random temperature errors were found to be less than 1 C at most levels, but random dewpoint errors ranged from 1 to 5 C. Total errors of both parameters were considerably greater, with dewpoint errors especially large on the day having a pronounced subsidence inversion. Cumulus cloud cover on 15 June limited HIS mesoscale analyses on that day. Previously undetected clouds were found in many HIS fields of view, and these probably produced the low-level horizontal temperature and dewpoint variations observed in the retrievals. HIS dewpoints at 300 mb indicated a strong moisture gradient that was confirmed by GOES 6.7-micron imagery. HIS mesoscale analyses on 19 June revealed a tongue of humid air stretching across the study area. The moist region was confirmed by radiosonde data and imagery from the Multispectral Atmospheric Mapping Sensor (MAMS). Convective temperatures derived from HIS retrievals helped explain the cloud formation that occurred after the HIS overflights. Crude estimates of Bowen ratio were obtained from HIS data using a mixing-line approach. Values indicated that areas of large sensible heat flux were the areas of first cloud development. These locations were also suggested by GOES visible and infrared imagery. The HIS retrievals indicated that areas of thunderstorm formation were regions of greatest instability. Local landscape variability and atmospheric temperature and humidity fluctuations were found to be important factors in producing the cumulus clouds on 19 June. HIS soundings were capable of detecting some of this variability. The authors were impressed by HIS's performance on the two study days.
Sodium-cooled fast reactors (SFR), which use high temperature fluid near ambient pressure as coolant, are one of the most promising types of GEN IV reactors. One of the unique challenges of SFR operation is purification of high temperature liquid sodium with a cold trap to prevent corrosion and obstructing small orifices. We have developed a deep learning long short-term memory (LSTM) autoencoder for continuous monitoring of a cold trap and detection of operational anomaly. Transient data were obtained from the Mechanisms Engineering Test Loop (METL) liquid sodium facility at Argonne National Laboratory. The cold trap purification at METL is monitored with 31 variables, which are sensors measuring fluid temperatures, pressures and flow rates, and controller signals. Loss-of-coolant type anomaly in the cold trap operation was generated by temporarily choking one of the blowers, which resulted in temperature and flow rate spikes. The input layer of the autoencoder consisted of all the variables involved in monitoring the cold trap. The LSTM autoencoder was trained on the data corresponding to cold trap startup and normal operation regime, with the loss function calculated as the mean absolute error (MAE). The loss during training was determined to follow log-normal density distribution. During monitoring, we investigated a performance of the LSTM autoencoder for different loss threshold values, set at a progressively increasing number of standard deviations from the mean. The anomaly signal in the data was gradually attenuated, while preserving the noise of the original time series, so that the signal-to-noise ratio (SNR) averaged across all sensors decreased below unity. Results demonstrate detection of anomalies with sensor-averaged SNR < 1.
A technique has been developed for assimilating GOES-derived skin temperature tendencies and insolation into the surface energy budget equation of a mesoscale model so that the simulated rate of temperature change closely agrees with the satellite observations. A critical assumption of the technique is that the availability of moisture (either from the soil or vegetation) is the least known term in the model's surface energy budget. Therefore, the simulated latent heat flux, which is a function of surface moisture availability, is adjusted based upon differences between the modeled and satellite-observed skin temperature tendencies. An advantage of this technique is that satellite temperature tendencies are assimilated in an energetically consistent manner that avoids energy imbalances and surface stability problems that arise from direct assimilation of surface shelter temperatures. The fact that the rate of change of the satellite skin temperature is used rather than the absolute temperature means that sensor calibration is not as critical. The technique has been employed on a semi-operational basis at the GHCC within the PSU/NCAR MM5. Assimilation has been performed on a grid centered over the Southeastern US since November 1998. Results from the past year show that assimilation of the satellite data reduces both the bias and RMSE for simulations of surface air temperature and relative humidity. These findings are based on comparison of assimilation runs with a control using the simple 5-layer soil model available in MM5. A significant development in the past several months was the inclusion of the detailed Oregon State University land surface model (OSU/LSM) as an option within MM5. One of our working hypotheses has been that the assimilation technique, although simple, may provide better short-term forecasts than a detailed LSM that requires significant number initialized parameters. Preliminary results indicate that the assimilation out performs the OSU/LSM as it is incorporated in MM5. Details will be presented at the symposium.
We use retrievals of atmospheric precipitable water from satellite microwave observations and analyses of near-surface temperature to examine the relationship between these two fields on daily and longer time scales. The retrieval technique producing the data used here is most effective over the open ocean, so the analysis focuses on the southern hemisphere's extratropics, which have an extensive ocean surface. For both the total and the eddy precipitable water fields, there is a close correspondence between local variations in the precipitable water and near-surface temperature. The correspondence appears particularly strong for synoptic and planetary scale transient eddies. More specifically, the results support a typical modeling assumption that transient eddy moisture fields are proportional to transient eddy temperature fields under the assumption f constant relative humidity.
A small laboratory diagnostic thruster was developed in order to evaluate approaches for the use of temperature and pressure sensors for the investigation of low thrust rocket flowfields. Tests were performed at chamber pressures of about 255 kPa, 370 kPa, and 500 kPa with oxidizer/fuel mixture ratios between 4.0 and 8.0. Two gaseous hydrogen/gaseous oxygen injector designs were tested with 60 and 75 fuel film cooling. The results of hot-wire tests showed the thruster and instrumentation designs to be effective. Azimuthal temperature distributions were found to be a function of operating conditions and hardware configuration. Results indicated that small differences in injector design can result in dramatically different thruster performance and wall temperature behavior. However, the importance of these injector effects may be decreased by operating at a high fuel film cooling rate.