Search NASA⌕ Search

SEARCH · Search NASA

Results for “Water Splitting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

OECD MCCI Project: 2-D Core Concrete Interaction (CCI) Tests (CCI-4 Final Report)

Ex-vessel debris coolability is an important light water reactor (LWR) safety issue. For existing plants, resolution of this issue will confirm the technical basis for severe accident management guidelines (SAMGs). For new reactors, understanding this issue will help confirm the effectiveness of the design and implementation of new accident mitigation features and severe accident management design alternatives (SAMDAs). The first OECD-MCCI program conducted reactor material experiments focused on achieving the following technical objectives: i) provide confirmatory evidence for various cooling mechanisms through separate effect tests and data for severe accident code model development, and ii) provide longer-term two-dimensional core-concrete interaction data for code assessment and improvement. As one of the steps in satisfying these program objectives, the Management Board (MB) approved the conduct of a fourth longer-term 2-D Core-Concrete Interaction (CCI) experiment designed to provide information in several areas, including: i) lateral vs. axial power split during dry core-concrete interaction, ii) integral debris coolability data following late phase flooding, and iii) data regarding the nature and extent of the cooling transient following breach of the crust formed at the melt-water interface. The first three tests investigated the interaction of fully oxidized PWR core melt compositions with specially designed concrete test sections that were initially 50 cm x 50 cm in cross-sectional area. Both siliceous and limestone/common sand concrete types were addressed in the test matrix. The fourth test that is addressed in this report, CCI-4, utilized a similar test apparatus and experiment boundary conditions, including a limestone/common sand concrete test section. However, instead of a fully oxidized PWR melt, CCI-4 utilized a partially oxidized BWR core melt containing ~ 8 wt % structural steel constituents. Thus, this test evaluated the effect of elevated melt metal content on two-dimensional cavity erosion and debris cooling behavior. The experiment was conducted on May 26, 2007, and early experiment results were reported in a quick-look data report. The objective of this final report is to document both the thermalhydraulic and posttest debris examination results for this test. To this end, a summary description of the test apparatus is provided first, followed by descriptions of the test operating procedure and experimental results that include both thermalhydraulic data and the findings from the posttest examinations. Overall specifications for CCI-4 are provided.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

OECD MMCI 2-D Core Concrete Interaction (CCI) tests : CCCI-1 test data report-thermalhydraulic results. Rev 0 January 31, 2004.

The Melt Attack and Coolability Experiments (MACE) program addressed the issue of the ability of water to cool and thermally stabilize a molten core-concrete interaction when the reactants are flooded from above. These tests provided data regarding the nature of corium interactions with concrete, the heat transfer rates from the melt to the overlying water pool, and the role of noncondensable gases in the mixing processes that contribute to melt quenching. As a follow-on program to MACE, The Melt Coolability and Concrete Interaction Experiments (MCCI) project is conducting reactor material experiments and associated analysis to achieve the following objectives: (1) resolve the ex-vessel debris coolability issue through a program that focuses on providing both confirmatory evidence and test data for the coolability mechanisms identified in MACE integral effects tests, and (2) address remaining uncertainties related to long-term two-dimensional molten coreconcrete interactions under both wet and dry cavity conditions. Achievement of these two program objectives will demonstrate the efficacy of severe accident management guidelines for existing plants, and provide the technical basis for better containment designs for future plants. In terms of satisfying these objectives, the Management Board (MB) approved the conduct of two long-term 2-D Core-Concrete Interaction (CCI) experiments designed to provide information in several areas, including: (i) lateral vs. axial power split during dry core-concrete interaction, (ii) integral debris coolability data following late phase flooding, and (iii) data regarding the nature and extent of the cooling transient following breach of the crust formed at the melt-water interface. This data report provides thermal hydraulic test results from the CCI-1 experiment, which was conducted on December 19, 2003. Test specifications for CCI-1 are provided in Table 1-1. This experiment investigated the interaction of a fully oxidized 400 kg PWR core melt, initially containing 8 wt % calcined siliceous concrete, with a specially designed two-dimensional siliceous concrete test section with an initial cross-sectional area of 50 cm x 50 cm. The report begins by providing a summary description of the CCI-1 test apparatus and operating procedures, followed by presentation of the thermal-hydraulic results. The posttest debris examination results will be provided in a subsequent publication. Observations drawn within this report regarding the overall cavity erosion behavior may be subject to revision once the posttest examinations are completed, since these examinations will fully reveal the final cavity shape.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Sensitivity of Fischer-Tropsch Synthesis and Water-Gas Shift Catalystes to Poisons form High-Temperature High-Pressure Entrained-Flow (EF) Oxygen-Blown Gasifier Gasification of Coal/Biomass Mixtures

There has been a recent shift in interest in converting not only natural gas and coal derived syngas to Fischer-Tropsch synthesis products, but also converting biomass-derived syngas, as well as syngas derived from coal and biomass mixtures. As such, conventional catalysts based on iron and cobalt may not be suitable without proper development. This is because, while ash, sulfur compounds, traces of metals, halide compounds, and nitrogen-containing chemicals will likely be lower in concentration in syngas derived from mixtures of coal and biomass (i.e., using entrained-flow oxygen-blown gasifier gasification gasification) than solely from coal, other compounds may actually be increased. Of particular concern are compounds containing alkali chemicals like the chlorides of sodium and potassium. In the first year, University of Kentucky Center for Applied Energy Research (UK-CAER) researchers completed a number of tasks aimed at evaluating the sensitivity of cobalt and iron-based Fischer-Tropsch synthesis (FT) catalysts and a commercial iron-chromia high temperature water-gas shift catalyst (WGS) to alkali halides. This included the preparation of large batches of 0.5%Pt-25%Co/Al{sub 2}O{sub 3} and 100Fe: 5.1Si: 3.0K: 2.0Cu (high alpha) catalysts that were split up among the four different entities participating in the overall project; the testing of the catalysts under clean FT and WGS conditions; the testing of the Fe-Cr WGS catalyst under conditions of co-feeding NaCl and KCl; and the construction and start-up of the continuously stirred tank reactors (CSTRs) for poisoning investigations.

01 COAL, LIGNITE, AND PEAT↗

OECD 2-D Core Concrete Interaction (CCI) tests : CCI-2 test plan, Rev. 0 January 31, 2004.

The Melt Attack and Coolability Experiments (MACE) program addressed the issue of the ability of water to cool and thermally stabilize a molten core-concrete interaction when the reactants are flooded from above. These tests provided data regarding the nature of corium interactions with concrete, the heat transfer rates from the melt to the overlying water pool, and the role of noncondensable gases in the mixing processes that contribute to melt quenching. As a follow-on program to MACE, The Melt Coolability and Concrete Interaction Experiments (MCCI) project is conducting reactor material experiments and associated analysis to achieve the following objectives: (1) resolve the ex-vessel debris coolability issue through a program that focuses on providing both confirmatory evidence and test data for the coolability mechanisms identified in MACE integral effects tests, and (2) address remaining uncertainties related to long-term two-dimensional molten core-concrete interactions under both wet and dry cavity conditions. Achievement of these two program objectives will demonstrate the efficacy of severe accident management guidelines for existing plants, and provide the technical basis for better containment designs for future plants. In terms of satisfying these objectives, the Management Board (MB) approved the conduct of two long-term 2-D Core-Concrete Interaction (CCI) experiments designed to provide information in several areas, including: (i) lateral vs. axial power split during dry core-concrete interaction, (ii) integral debris coolability data following late phase flooding, and (iii) data regarding the nature and extent of the cooling transient following breach of the crust formed at the melt-water interface. The first of these two tests, CCI-1, was conducted on December 19, 2003. This test investigated the interaction of a fully oxidized 400 kg PWR core melt, initially containing 8 wt % calcined siliceous concrete, with a specially designed two-dimensional siliceous concrete test section with an initial cross-sectional area of 50 cm x 50 cm. The second of these two planned tests, CCI-2, will be conducted with a nearly identical test facility and experiment boundary conditions, but with a Limestone/Common Sand (LCS) concrete test section to investigate the effect of concrete type on the two-dimensional core-concrete interaction and debris cooling behavior. The objective of this report is to provide the overall test plan for CCI-2 to enable pretest calculations to be carried out. The report begins by providing a summary description of the CCI-2 test apparatus, followed by a description of the planned test operating procedure. Overall specifications for CCI-2 are provided in Table 1-1.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

OECD MCCI 2-D Core Concrete Interaction (CCI) tests : CCI-2 test data report-thermalhydraulic results, Rev. 0 October 15, 2004.

The Melt Attack and Coolability Experiments (MACE) program addressed the issue of the ability of water to cool and thermally stabilize a molten core-concrete interaction when the reactants are flooded from above. These tests provided data regarding the nature of corium interactions with concrete, the heat transfer rates from the melt to the overlying water pool, and the role of noncondensable gases in the mixing processes that contribute to melt quenching. As a follow-on program to MACE, The Melt Coolability and Concrete Interaction Experiments (MCCI) project is conducting reactor material experiments and associated analysis to achieve the following objectives: (1) resolve the ex-vessel debris coolability issue through a program that focuses on providing both confirmatory evidence and test data for the coolability mechanisms identified in MACE integral effects tests, and (2) address remaining uncertainties related to long-term two-dimensional molten core-concrete interactions under both wet and dry cavity conditions. Achievement of these two program objectives will demonstrate the efficacy of severe accident management guidelines for existing plants, and provide the technical basis for better containment designs for future plants. In terms of satisfying these objectives, the Management Board (MB) approved the conduct of two long-term 2-D Core-Concrete Interaction (CCI) experiments designed to provide information in several areas, including: (i) lateral vs. axial power split during dry core-concrete interaction, (ii) integral debris coolability data following late phase flooding, and (iii) data regarding the nature and extent of the cooling transient following breach of the crust formed at the melt-water interface. This data report provides thermal hydraulic test results from the CCI-2 experiment, which was conducted on August 24, 2004. Test specifications for CCI-2 are provided in Table 1-1. This experiment investigated the interaction of a fully oxidized 400 kg PWR core melt, initially containing 8 wt % Limestone/Common Sand (LCS) concrete, with a specially designed two-dimensional LCS concrete test section with an initial cross-sectional area of 50 cm x 50 cm. The report begins by providing a summary description of the CCI-2 test apparatus and operating procedures, followed by presentation of the thermal-hydraulic results. Detailed posttest debris examination results will be provided in a subsequent publication. Observations drawn within this report regarding the overall cavity erosion behavior may be subject to revision once the posttest examinations are completed, since these examinations will fully reveal the final cavity shape.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

OECD MCCI project 2-D Core Concrete Interaction (CCI) tests : CCI-3 test data report-thermalhydraulic results. Rev. 0 October 15, 2005.

The Melt Attack and Coolability Experiments (MACE) program addressed the issue of the ability of water to cool and thermally stabilize a molten core-concrete interaction when the reactants are flooded from above. These tests provided data regarding the nature of corium interactions with concrete, the heat transfer rates from the melt to the overlying water pool, and the role of noncondensable gases in the mixing processes that contribute to melt quenching. As a follow-on program to MACE, The Melt Coolability and Concrete Interaction Experiments (MCCI) project is conducting reactor material experiments and associated analysis to achieve the following objectives: (1) resolve the ex-vessel debris coolability issue through a program that focuses on providing both confirmatory evidence and test data for the coolability mechanisms identified in MACE integral effects tests, and (2) address remaining uncertainties related to long-term two-dimensional molten core-concrete interactions under both wet and dry cavity conditions. Achievement of these two program objectives will demonstrate the efficacy of severe accident management guidelines for existing plants, and provide the technical basis for better containment designs for future plants. In terms of satisfying these objectives, the Management Board (MB) approved the conduct of a third long-term 2-D Core-Concrete Interaction (CCI) experiment designed to provide information in several areas, including: (i) lateral vs. axial power split during dry core-concrete interaction, (ii) integral debris coolability data following late phase flooding, and (iii) data regarding the nature and extent of the cooling transient following breach of the crust formed at the melt-water interface. This data report provides thermal hydraulic test results from the CCI-3 experiment, which was conducted on September 22, 2005. Test specifications for CCI-3 are provided in Table 1-1. This experiment investigated the interaction of a fully oxidized 375 kg PWR core melt, initially containing 15 wt% siliceous concrete, with a specially designed two-dimensional siliceous concrete test section with an initial cross-sectional area of 50 cm x 50 cm. The sand and aggregate constituents for this particular siliceous concrete were provided by CEA as an in-kind contribution to the program. The report begins by providing a summary description of the CCI-3 test apparatus and operating procedures, followed by presentation of the thermal-hydraulic results. Detailed posttest debris examination results will be provided in a subsequent publication. Observations drawn within this report regarding the overall cavity erosion behavior may be subject to revision once the posttest examinations are completed, since these examinations will fully reveal the final cavity shape.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A PENELOPE-based system for the automated Monte Carlo simulation of clinacs and voxelized geometries - application to far-from-axis fields

Purpose: Two new codes, PENEASY and PENEASYLINAC, which automate the Monte Carlo simulation of Varian Clinacs of the 600, 1800, 2100, and 2300 series, together with their electron applicators and multileaf collimators, are introduced. The challenging case of a relatively small and far-from-axis field has been studied with these tools. Methods: PENEASY is a modular, general-purpose main program for the PENELOPE Monte Carlo system that includes various source models, tallies and variance-reduction techniques (VRT). The code includes a new geometry model that allows the superposition of voxels and objects limited by quadric surfaces. A variant of the VRT known as particle splitting, called fan splitting, is also introduced. PENEASYLINAC, in turn, automatically generates detailed geometry and configuration files to simulate linacs with PENEASY. These tools are applied to the generation of phase-space files, and of the corresponding absorbed dose distributions in water, for two 6 MV photon beams from a Varian Clinac 2100 C/D: a 40 x 40 cm{sup 2} centered field; and a 3 x 5 cm{sup 2} field centered at (4.5, -11.5) cm from the beam central axis. This latter configuration implies the largest possible over-traveling values of two of the jaws. Simulation results for the depth dose and lateral profiles at various depths are compared, by using the gamma index, with experimental values obtained with a PTW 31002 ionization chamber. The contribution of several VRTs to the computing speed of the more demanding off-axis case is analyzed. Results: For the 40 x 40 cm{sup 2} field, the percentages {gamma}{sub 1} and {gamma}{sub 1.2} of voxels with gamma indices (using 0.2 cm and 2% criteria) larger than unity and larger than 1.2 are 0.2% and 0%, respectively. For the 3 x 5 cm{sup 2} field, {gamma}{sub 1} = 0%. These figures indicate an excellent agreement between simulation and experiment. The dose distribution for the off-axis case with voxels of 2.5 x 2.5 x 2.5 mm{sup 3} and an average standard statistical uncertainty of 2% (1{sigma}) is computed in 3.1 h on a single core of a 2.8 GHz Intel Core 2 Duo processor. This result is obtained with the optimal combination of the tested VRTs. In particular, fan splitting for the off-axis case accelerates execution by a factor of 240 with respect to standard particle splitting. Conclusions: PENEASY and PENEASYLINAC can simulate the considered Varian Clinacs both in an accurate and efficient manner. Fan splitting is crucial to achieve simulation results for the off-axis field in an affordable amount of CPU time. Work to include Elekta linacs and to develop a graphical interface that will facilitate user input is underway.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SANS study of HC1 extraction by selected neutral organophosphorus compounds in n-octane.

The extraction of HCl by tri(2-ethylhexyl) phosphate (TEHP), tri-n-octyl phosphate (TOP), and tri-n-octylphosphine oxide (TOPO) in n-octane was investigated by liquid-liquid distribution of acid and water and small-angle neutron scattering (SANS) measurements. No formation of a heavy organic phase (third phase) was observed with TEHP and TOP under the experimental conditions used, whereas for 0.4 M TOPO the HCl limiting organic concentration (LOC) at 23 C was 0.32 M (with 5.1 M HCl in the equilibrium aqueous phase). For higher HCl concentrations in the aqueous phase, the organic phase splits into a light and a heavy layer. For TEHP and TOP, the SANS results, interpreted using the Baxter model for hard spheres with surface adhesion, indicated the formation of only small reverse micelles with little intermicellar attraction. For TOPO, the scattering signals suggested the formation of much larger and strongly interacting micelles. The critical values of the stickiness parameter, {tau}{sup -1}, and the interaction potential energy, U(r), for the LOC sample in the TOPO system were consistent with the model for third-phase formation previously developed for tri-n-butyl phosphate (TBP). According to this model, organic phase splitting is due to van der Waals interactions between the polar cores of reverse micelles formed by the extractants in the organic phase.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Onset dynamics of air-water menisci on rock fracture surfaces

Information on menisci dynamics and equilibrium contact angles, θ e , is needed for modeling multiphase flow of fluids in geologic formations. The wettability of fracture faces is relevant to applications such as waterflooding in enhanced oil recovery and evaluation of caprock integrity for geologic carbon sequestration. We investigated the vertical capillary rise of air-water menisci on exposed fracture faces for a sandstone, a shale, and three granites. The experimental design approximated that employed in the Wilhelmy plate method. Replicate fracture faces were prepared by fracturing cylindrical rock cores using the Brazilian method and splitting the fractured cores apart along their fracture planes. Meniscus onset was imaged from a cross-sectional perspective using dynamic neutron radiography, and quantified with change point analysis. An existing model for meniscus onset fitted the experimental data very well (median R 2 = 0.96). Capillary rise was typified by t 2/3 scaling (where t is time), followed by a constant equilibrium height, z e . The average time taken for the menisci to reach z e was 0.39 s, with no differences between rock types. The menisci achieved a greater vertical extent on the fracture faces of the sedimentary rocks as compared to those of the granites. Apparent θ e values were calculated from the best fit estimates of z e using the Wilhelmy plate equation for a smooth and planar vertical surface. Despite the fractal roughness of some of the fracture faces, there was a significant linear relationship (R 2 = 0.80) between the apparent θ e values and intrinsic θ e values measured on polished surfaces of the same rocks using the sessile drop method. The regression equation indicated the apparent θ e values were consistently greater than the intrinsic values. This overestimation may be due to averaging of pixels at the air-water-solid interface, a required step in the image analysis. Further exploration of the range of applicability and measurement accuracy of this proposed new technique would be valuable.

58 GEOSCIENCES↗

Electronic structure effects in liquid water studied by photoelectron spectroscopy and density functional theory

We present valence photoelectron emission spectra of liquid water in comparison with gas-phase water, ice close to the melting point, low temperature amorphous and crystalline ice. All aggregation states have major electronic structure changes relative to the free molecule, with rehybridization and development of bonding and anti-bonding states accompanying the hydrogen bond formation. Sensitivity to the local structural order, most prominent in the shape and splitting of the occupied 3a{sub 1} orbital, is understood from the electronic structure averaging over various geometrical structures, and reflects the local nature of the orbital interaction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Transmissive microfluidic active cooling for concentrator photovoltaics

We present the design, fabrication, characterization, and field testing of transmissive active cooling for use in a point-focus spectrum-splitting hybrid concentrator photovoltaics/thermal (CPV/T) system. Seven parallel-path 100 μm thick microchannels are made using polydimethylsiloxane and attached to a CPV module containing a 6 × 6 array of 5.5 mm transmissive CPV cells on a sapphire substrate. Water is flowed through the microchannels to actively cool the CPV cells. The total transmittance of the CPV module reduces by 5.2% with the addition of the active cooling microchannels, relative to the module transmission with no microchannels. The peak cell temperature is measured as 69 °C with a thermal resistance of 9.35 K/W at 157 suns, well below the 110 °C maximum allowed temperature. A maximum flowrate of 16.7 g/s is achieved from a 13 psi pressure drop across the microchannels and manifold assembly. The flow characteristics within each microfluidic channel show maximum fluid velocity of 4.3 m/s (Re = 953) with a calculated convection coefficient of 1.7 × 10 4 W/m 2 K (Nu = 5.36). The CPV/T module and cooling system performance was validated during week-long outdoor tests under varying solar conditions up to 250 suns using a 2.7 m 2 parabolic dish collector mounted to a two-axis tracking system.

14 SOLAR ENERGY↗

Velocity Crossover Between Hydrous and Anhydrous Forsterite at High Pressures

The elastic properties of hydrous forsterite, Mg{sub 2-x}SiO{sub 4}H{sub 2x}, are relevant to interpreting seismic velocity anomalies in the Earth's mantle. In this study, we used Brillouin scattering to determine the single-crystal elasticity of forsterite with 0.9(1) wt.% H{sub 2}O (x = 0.14) to 14 GPa. Aggregate bulk and shear moduli of hydrous forsterite increase with pressure at a greater rate than those of the corresponding anhydrous phase. Compared with anhydrous forsterite, we observe a 7% increase in the pressure derivative of the bulk modulus (K{prime}{sub S0} = 4.50(5)), and a 25% increase in the pressure derivative of the shear modulus (G{prime}{sub 0} = 1.75(5)) for forsterite with near maximum possible water content. Using our results, we calculated the compressional, V{sub P}, and shear, V{sub S}, velocities of forsterite as a function of pressure at 300 K. Whereas V{sub P} and V{sub S} of hydrous forsterite are 0.6% and 0.4% slower than those of anhydrous forsterite at ambient pressure, velocity crossovers at {approx} 3-4 GPa result in higher hydrous forsterite velocities at pressures corresponding to depths below {approx} 120 km. At the pressure of the 410-km discontinuity, V{sub P} and V{sub S} of hydrous forsterite exceed those of anhydrous forsterite by 1.1(1)% and 1.9(1)%, respectively. This implies that incorporation of water could decrease the magnitude of the velocity contrast at 410-km depth between forsterite and wadsleyite. Although the effects of hydration on temperature derivatives of the elastic moduli of forsterite and wadsleyite are not yet known, from the current data we estimate that the presence of {approx} 0.4 wt.% H{sub 2}O in forsterite (at 60 mol%) could lower the P and S velocity contrast at 410-km depth to 3.8(4)% and 4.8(6)%, respectively. At high pressures, hydration also decreases the V{sub P}/V{sub S} ratio of forsterite, and lowers the maximum P wave azimuthal anisotropy and S wave splitting of forsterite.

79 ASTRONOMY AND ASTROPHYSICS↗

Expeditious modeling of vapor transport and reactions in polymeric materials

We present a methodology for approximating dynamic adsorption of vapor coupled with diffusion in polymeric materials. In previous publications, the dynamic adsorption was represented by ordinary differential equations (ODEs) and solved in concentration and parameter space. To accelerate the calculation, we have developed a statistical approximation method using computationally cheap surrogate models (e.g., algebraic polynomials) that replace the ODE solutions of adsorption and are coupled with the diffusion equations. Since the polynomial presentation of the adsorption term is obtained in a standard format prior to modeling coupled sorption‐diffusion, the adsorption operator can be expressed as input data in the transport code. Compared to conventional operator‐splitting methods, the polynomial approximation of adsorption offers better computational efficiency. The methodology is demonstrated and validated using a dynamic Langmuir adsorption model that is coupled to diffusion and absorption models and applied to a water vapor sorption‐diffusion process in polydimethylsiloxane polymers. © 2017 American Institute of Chemical Engineers AIChE J , 63: 4079–4089, 2017

Sun, Yunwei↗

A Process with Decoupled Absorber Kinetics and Solvent Regeneration through Membrane Dewatering and In-Column Heat Transfer (Final Report)

This report summarizes the work conducted on project DE-FE0031604 where University of Kentucky Center for Applied Energy (UK CAER) has validated its intensified CO 2 capture process through substantial enhancements to the kinetics of the absorption process and energy reductions by absorber temperature profile modification, dewatering and heat integration technologies for achieving significant capital and operating cost reductions. To address DOE’s objective of improving post-combustion CO 2 capture technology and reducing associated cost, UK CAER employed an intensified process which combined three key aspects targeted at overcoming inherent limitations or barriers in the conventional CO 2 capture and desorption process. The process designed to be independent of the type of solvent used, included (1) the use of 3-D printed two-channel structured packing material to control the temperature profile and increase the CO 2 absorption rate in the absorber, (2) a zeolite membrane dewatering unit for dewatering of the carbon-rich solvent to decouple solvent concentration needs for CO 2 absorption and desorption, and (3) a rich-split feed with two-phase flow heat transfer prior to the stripper that provided a secondary point of vapor generation to provide energy savings in steam extraction and solvent regeneration. The project was executed over two budget periods. This involved testing of individual process components which included the advanced heat transfer packing and the dewatering membrane on UK CAER’s 30 liter per minute (L/min) CO 2 (3” Column) capture bench unit with simulated flue gas in the first budget period. Subsequent scaled-up testing of these components together with the split-feed configuration were also tested in UK CAER’s 0.1 MWth CO 2 capture unit with coal-derived flue gas in the second-budget period. Long term studies were done during this period to assess process and solvent performance over extended duration. Project partners Lawrence Livermore National Laboratory (LLNL) and Media & Process Technology (MPT) led the development efforts for the advanced packing material and dewatering membrane respectively. Data from the long term testing was used as input for an environmental, health and safety (EH&S) assessment for the process and scaled technology performed by ALL4 LLC. Trimeric Corporation also completed a techno-economic analysis (TEA) for the UK CAER technology which was compared to the DOE reference Case B12B. Tests on the 3” column capture unit showed that the advanced heat transfer packing could be used to lower the bulge temperature in the absorber, and this was also proven in the scaled testing in the 0.1 MWth CO 2 capture unit. The bulge temperature could be lowered by >10 °C, changing the temperature profile in the absorber, and showed potential to enhance absorption with the ability to tailor the profile to provide conditions suitable for a solvent’s properties and kinetics. Conditions for short term evaluation of a 19” zeolite dewatering membrane on the 3” column capture unit yielded desirable fluxes and sustained rejection rates of >80%. However, for the scaled testing of six membrane modules consisting of 21 parts of 31-inch-long membrane tubes in each bundle (surface area 0.3 m 2 ), over a more extended duration, similar rejection rates could not be achieved. With the split-feed of the rich stream to the stripper, improved heat recovery minimized waste heat exiting the top of the stripper. The stripper exhaust temperatures could be reduced by >10 °C; reducing the amount of water vaporization contributed to lowering the regeneration energy by ~ 15%. The energy benefit could be sustained from the long term monitoring of the solvent performance. The solvent properties were not significantly impacted over the long-term operations. The benefits of the UK CAER process demonstrated experimentally were mostly validated from the TEA comparing a commercial scale application of the technology to DOE reference Case B12B. The cost of CO 2 capture for the UK CAER technology was estimated to be ~$34.97/tonne of CO 2 captured; a reduction of 23% compared to Case B12B. The increase in cost of electricity was also shown to be 16% lower than that of Case B12B. The total parasitic demand was also shown to be 11% lower. The key drivers for the benefits are a result of the process intensification approaches employed in the UK CAER technology for enhanced solvent performance, effective heat recovery and improved energy performance. The EH&S assessment did not find any major environmental concerns or barriers to the full scale implementation of the technology.

20 FOSSIL-FUELED POWER PLANTS↗

Understanding the Scale of the Single Ion Free Energy: A Critical Test of the Tetra-Phenyl Arsonium and Tetra-Phenyl Borate Assumption

Free energies, enthalpies and entropies of ions in solution can be experimentally determined for neutral pairs. For individual ions however, determining these properties requires additional assumptions, which can and should be theoretically tested. The tetra-phenyl arsonium and tetra-phenyl borate (TATB) assumption is a commonly used extra-thermodynamic assumption, which allows these values to be split into cationic and anionic contributions. The assumption is that the values for the TATB salt can be divided equally. This is justified by arguing that these large hydrophobic ions will cause a symmetric response in water. Experimental and classical simulation work has raised potential flaws with this assumption, indicating that hydrogen bonding with the phenyl ring may favor the solvation of the TB-anion. In this study, we perform ab initio molecular dynamics (AIMD) simulations of these ions in bulk water demonstrating that there are significant structural differences. We quantify our findings by reproducing the experimentally observed vibrational shift for the TB-anion and confirm that this is associated with hydrogen bonding with the phenyl rings. Finally, we demonstrate that this results in a substantial energetic preference of the water to solvate the anion. In conclusion, our results suggest that the validity of the TATB assumption, which is still widely used today, should be reconsidered experimentally in order to properly reference single ion solvation free energy, enthalpy and entropy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a Couette-Taylor flow device with active minimization of secondary circulation

A novel Taylor-Couette experiment has been developed to produce rotating shear ows for the study of hydrodynamic and magnetohydrodynamic instabilities which are believed to drive angular momentum transport in astrophysical accretion disks. High speed, concentric, corotating cylinders generate the flow where the height of the cylinders is twice the radial gap width. Ekman pumping is controlled and minimized by splitting the vertical boundaries into pairs of nested, differentially rotating rings. The end rings and cylinders comprise four independently driven rotating components which provide exibility in developing flow profiles. The working fluids of the experiment are water, a water-glycerol mix, or a liquid gallium alloy. The mechanical complexity of the apparatus and large dynamic pressures generated by high speed operation with the gallium alloy presented unique challenges. The mechanical implementation of the experiment and some representative results obtained with Laser Doppler Velocimetry in water are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lessons Learned: Summary of Insights From the HERO WEC and Waves to Water Deployments Between 2022 and 2024

In 2020, a team from the National Renewable Energy Laboratory (NREL) partnered with the East Carolina University Coastal Studies Institute to develop a small, modular, wave-powered point absorber desalination prototype. That prototype, known as the hydraulic and electric reverse osmosis wave energy converter (HERO WEC), was intended to de-risk the installation activities planned for the Waves to Water Prize sponsored by the Water Power Technologies Office. The NREL team was given approximately 18 months to design, build, bench test, and deploy the HERO WEC prototype. Since the initial HERO WEC development, it has been used for two in-lab test programs and three ocean deployments. The first in-lab test program focused on ensuring that the overall operation of the device occurred as expected and on validating the operation of safety systems such as pressure relief valves or electrical breakers for load mitigation. The second in-lab test program was the first time the NREL team leveraged NREL’s large-amplitude motion platform to characterize the performance of the HERO WEC. Of the three in-water deployments, the first deployment was effectively an installation and recovery practice with no meaningful wave activity during the time that it was installed. The second deployment was a 2-week effort that enabled both the electric and hydraulic configurations of the device to be in the water for approximately 5 days each. This deployment was also the first time that the team had the opportunity to perform a drivetrain swap on the Coastal Studies Institute research vessel. The third deployment had to be split into two separate installations due to minor damage incurred from the WEC spinning during the initial installation. This report summarizes the deployments, the challenges encountered with each deployment, and the lessons learned for future work.

16 TIDAL AND WAVE POWER↗