Search NASA⌕ Search

SEARCH · Search NASA

Results for “distributed electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Effect of antenna size on electron kinetics in inductively coupled plasmas

Spatially resolved measurements of electron energy distribution functions (EEDFs) are investigated in inductively coupled plasmas with two planar antenna coils. When the plasma is sustained by the antenna with a diameter of 18 cm, the nonlocal kinetics is preserved in the argon gas pressure range from 2 mTorr to 20 mTorr. However, electron kinetics transit from nonlocal kinetics to local kinetics in discharge sustained by the antenna coil with diameter 34 cm. The results suggest that antenna size as well as chamber length are important parameters for the transition of the electron kinetics. Spatial variations of plasma potential, effective electron temperature, and EEDF in terms of total electron energy scale are also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Self-sustained criterion with photoionization for positive dc corona plasmas between coaxial cylinders

The positive dc corona plasmas between coaxial cylinders in air under the application of a self-sustained criterion with photoionization are investigated in this paper. A photon absorption function suitable for cylindrical electrode, which can characterize the total photons within the ionization region, is proposed on the basis of the classic corona onset criteria. Based on the general fluid model with the self-sustained criterion, the role of photoionization in the ionization region is clarified. It is found that the surface electric field keeps constant under a relatively low corona current, while it is slightly weakened with the increase of the corona current. Similar tendencies can be found under different conductor radii and relative air densities. The small change of the surface electric field will become more significant for the electron density distribution as well as the ionization activity under a high corona current, compared with the results under the assumption of a constant surface field. The assumption that the surface electric field remains constant should be corrected with the increase of the corona current when the energetic electrons with a distance from the conductor surface are concerned.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Survey of Surgical Oncology Fellowship Graduates 2005–2016: Insight into Initial Practice

Background: Despite burgeoning interest in Complex General Surgical Oncology (CGSO) fellowship training, little is reported about postgraduate employment. The goal of this study was to characterize CGSO graduates’ first employment and to identify factors that influenced this decision. Methods: The National Cancer Institute (NCI) and Society of Surgical Oncology developed and distributed an electronic survey to CGSO fellows who graduated from 2005 to 2016. Results: The survey response rate was 47% (237/509). Fifty-seven percent of respondents were first employed as faculty surgeons at a university-based/affiliated hospital, with 15% returning to their residency institution. The distribution of respondents’ current employment across the United States mirrored the locations of their hometowns. Eighty-five percent of respondents care for patients across at least three disease types, most commonly hepatopancreatobiliary (81%), esophagus/gastric (75%), and sarcoma (74%). Twenty-seven percent of respondents spend the majority of their time in one area of surgical oncology; melanoma, breast, and head/neck were the most common. Two-thirds of respondents (67%) reported that they performed either clinical or basic science research as part of their current position. Multiple factors influenced the decision of first faculty position. Conclusions: Most CGSO graduates are employed at academic medical centers across the country in proximity to NCI-designated centers, treat a variety of disease types, and spend a percentage of their time dedicated to clinical research.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A precision measurement of the w boson mass at D0

I present the first measurement of the W boson mass in the electron decay channel using the Run II D0 detector at the Fermilab Tevatron Collider. The data used was collected from 2002 to 2006 and the integrated luminosity is 1 fb{sup -1}. The W boson mass was determined from the likelihood fit to the measured data distribution. The mass value is found to be 80.401 {+-} 0.023(stat) {+-} 0.037(syst) GeV = 80.401 {+-} 0.044 GeV using the transverse mass spectrum, which is the most precise measurement from one single experiment to date. This result puts tighter constraints on the mass of the standard model Higgs boson. I also present three other measurements that can help to reduce the theoretical uncertainties for the future W mass measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Generation of strongly coupled Xe cluster nanoplasmas by low intensive soft x-ray laser irradiation

A seeding gas jet including Xe clusters was irradiated with a laser-driven plasma soft x-ray laser pulse ({lambda}=13.9 nm, {approx}7 ps, {<=}5 Multiplication-Sign 10{sup 9} W/cm{sup 2}), where the laser photon energy is high enough to ionize 4d core electrons. In order to clarify how the innershell ionization followed by the Auger electron emission is affected under the intense laser irradiation, the electron energy distribution was measured. Photoelectron spectra showed that the peak position attributed to 4d hole shifted to lower energy and the spectral width was broadened with increasing cluster size. Moreover, the energy distribution exhibited that a strongly coupled cluster nanoplasma with several eV was generated.

74 ATOMIC AND MOLECULAR PHYSICS↗

Optimisation of An HHG-Seeded Harmonic Cascade FEL Design for the NLS Project

Optimization studies of an HHG-seeded harmonic cascade FEL design for the UK's proposed New Light Source (NLS) facility are presented. Three separate FELs are planned to meet the requirements for continuous coverage of the photon energy range 50-1000 eV with variable polarization, 20 fs pulse widths and good temporal coherence. The design uses an HHG seed source tuneable from 50-100 eV to provide direct FEL seeding in this range, and one or two stage harmonic cascades to reach the higher photon energies. Studies have been carried out to optimize a harmonic cascade FEL operating at 1 keV; topics investigated include modulator configuration, seed power level and ef- fects of the HHG seed structure. FEL simulations using realistic electron beam distributions are presented and tolerance to increased emittance has been considered.

43 PARTICLE ACCELERATORS↗

Ponderomotive self-focusing of Gaussian laser beam in warm collisional plasma

The propagation characteristics of a Gaussian laser beam through warm collisional plasma are investigated by considering the ponderomotive force nonlinearity and the complex eikonal function. By introducing the dielectric permittivity of warm unmagnetized plasma and using the WKB and paraxial ray approximations, the coupled differential equations defining the variations of laser beam parameters are obtained and solved numerically. Effects of laser and plasma parameters such as the collision frequency, the initial laser intensity and its spot size on the beam width parameter and the axis laser intensity distribution are analyzed. It is shown that, self-focusing of the laser beam takes place faster by increasing the collision frequency and initial laser spot size and then after some distance propagation the laser beam abruptly loses its initial diameter and vastly diverges. Furthermore, the modified electron density distribution is obtained and the collision frequency effect on this distribution is studied.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Incoherent Thomson scattering system for PHAse space MApping (PHASMA) experiment

A new incoherent Thomson scattering system measures the evolution of electron velocity distribution functions perpendicular and parallel to the ambient magnetic field during kinking of a single flux rope and merging of two flux ropes through magnetic reconnection. The Thom-son scattering system provides sub-millimeter spatial resolution, sufficient to diagnose the several millimeters sized magnetic reconnection electron diffusion region in the PHAse Space MAppgin experiment. Due to the relatively modest plasma density ~ 10 19 m -3 and electron tem-perature ~1 eV, stray light suppression is critical for these measurements. Two volume Bragg gratings are used in series as a notch filter with a spectral bandwidth <0.1 nm in the collection branch. A CCD with a Gen III intensifier with peak quantum efficiency >47% is used as the detector in a 1.3 m spectrometer. Preliminary results of gun plasma electron temperature will be reported and compared with measurements obtained from a triple Langmuir probe.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experiments and global model of inductively coupled rf Ar/N{sub 2} discharges

Experiments with a Langmuir probe and optical emission spectroscopy are carried out in inductively coupled rf (13.56 MHz) Ar/N{sub 2} discharges at three total pressures of 30, 60, and 110 mTorr, varying the Ar fractions from 50% to 95%. The electron energy probability functions (EEPFs) measured at all Ar fractions can be approximated using different exponentials in the bulk and high-energy regions, resulting in two temperature approximation of the measured EEPFs. The electron density slightly increases with increasing the Ar fraction at the Ar fractions below 70%, beyond which it relatively abruptly increases. On the other hand, the electron temperatures gradually decrease with the increase in the Ar fraction. The vibrational temperature does not strongly depend on the Ar fraction, whereas the rotational temperature gradually increases with the increase in the Ar fraction. The density of nitrogen atoms remains constant at the Ar fractions below 80%, beyond which it monotonically decreases with increasing the Ar fraction. A global model for electropositive plasma is used in order to investigate the plasma chemistry in Ar/N{sub 2} discharges assuming the Maxwellian electron energy distribution. The model results are compared with the experimental results, obtaining reasonably good agreement.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

VERY LARGE ARRAY OBSERVATIONS OF THE INFRARED DARK CLOUD G19.30+0.07

We present Very Large Array observations of ammonia (NH{sub 3}) (1,1), (2,2), and dicarbon sulfide (CCS) (2{sub 1}-1{sub 0}) emission toward the infrared dark cloud (IRDC) G19.30+0.07 at {approx}22 GHz. The NH{sub 3} emission closely follows the 8 {mu}m extinction. The NH{sub 3} (1,1) and (2,2) lines provide diagnostics of the temperature and density structure within the IRDC, with typical rotation temperatures of {approx}10-20 K and NH{sub 3} column densities of {approx}10{sup 15} cm{sup -2}. The estimated total mass of G19.30+0.07 is {approx}1130 M{sub sun}. The cloud comprises four compact NH{sub 3} clumps of mass {approx}30-160 M{sub sun}. Two coincide with 24 {mu}m emission, indicating heating by protostars, and show evidence of outflow in the NH{sub 3} emission. We report a water maser associated with a third clump; the fourth clump is apparently starless. A non-detection of 8.4 GHz emission suggests that the IRDC contains no bright H II regions and places a limit on the spectral type of an embedded zero-age main-sequence star to early-B or later. From the NH{sub 3} emission, we find that G19.30+0.07 is composed of three distinct velocity components or 'subclouds'. One velocity component contains the two 24 {mu}m sources and the starless clump, another contains the clump with the water maser, while the third velocity component is diffuse, with no significant high-density peaks. The spatial distribution of NH{sub 3} and CCS emission from G19.30+0.07 is highly anti-correlated, with the NH{sub 3} predominantly in the high-density clumps and the CCS tracing lower-density envelopes around those clumps. This spatial distribution is consistent with theories of evolution for chemically young low-mass cores, in which CCS has not yet been processed to other species and/or depleted in high-density regions.

79 ASTRONOMY AND ASTROPHYSICS↗

Fast flavor instability in hypermassive neutron star disk outflows

Here, we examine the effect of neutrino flavor transformation by the fast flavor instability (FFI) on long-term mass ejection from accretion disks formed after neutron star mergers. Neutrino emission and absorption in the disk set the composition of the disk ejecta, which subsequently undergoes r-process nucleosynthesis upon expansion and cooling. Here we perform 28 time-dependent, axisymmetric, viscous-hydrodynamic simulations of accretion disks around hypermassive neutron stars (HMNSs) of variable lifetime, using a 3-species neutrino leakage scheme for emission and an annular-lightbulb scheme for absorption. We include neutrino flavor transformation due the FFI in a parametric way, by modifying the absorbed neutrino fluxes and temperatures, allowing for flavor mixing at various levels of flavor equilibration, and also in a way that aims to respect the lepton-number preserving symmetry of the neutrino self-interaction Hamiltonian. We find that for a promptly-formed black hole (BH), the FFI lowers the average electron fraction of the disk outflow due to a decrease in neutrino absorption, driven primarily by a drop in electron neutrino/antineutrino flux upon flavor mixing. For a long-lived HMNS, the disk emits more heavy lepton neutrinos and reabsorbs more electron neutrinos than for a BH, with a smaller drop in flux compensated by a higher neutrino temperature upon flavor mixing. The resulting outflow has a broader electron fraction distribution, a more proton-rich peak, and undergoes stronger radiative driving. Disks with intermediate HMNS lifetimes show results that fall in between these two limits. In most cases, the impact of the FFI on the outflow is moderate, with changes in mass ejection, average velocity, and average electron fraction of order ~10%, and changes in the lanthanide/actinide mass fraction of up to a factor ~2.

79 ASTRONOMY AND ASTROPHYSICS↗

Strong-Field Modulated Diffraction Effects in the Correlated Electron-Nuclear Motion in Dissociating H{sub 2}{sup +}

We show that the electronic dynamics in a molecule driven by a strong field is complex and potentially even counterintuitive. As a prototype example, we simulate the interaction of a dissociating H{sub 2}{sup +} molecule with an intense infrared laser pulse. Depending on the laser intensity, the direction of the electron's motion between the two nuclei is found to follow or oppose the classical laser-electric force. We explain the sensitive dependence of the correlated electronic-nuclear motion in terms of the diffracting electronic momentum distribution of the dissociating two-center system. The distribution is dynamically modulated by the nuclear motion and periodically shifted in the oscillating infrared electric field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Perpendicular Diffusion of Solar Energetic Particles: Model Results and Implications for Electrons

The processes responsible for the effective longitudinal transport of solar energetic particles (SEPs) are still not completely understood. We address this issue by simulating SEP electron propagation using a spatially 2D transport model that includes perpendicular diffusion. By implementing, as far as possible, the most reasonable estimates of the transport (diffusion) coefficients, we compare our results, in a qualitative manner, to recent observations at energies of 55–105 keV, focusing on the longitudinal distribution of the peak intensity, the maximum anisotropy, and the onset time. By using transport coefficients that are derived from first principles, we limit the number of free parameters in the model to (i) the probability of SEPs following diffusing magnetic field lines, quantified by a∈[0,1], and (ii) the broadness of the Gaussian injection function. It is found that the model solutions are extremely sensitive to the magnitude of the perpendicular diffusion coefficient and relatively insensitive to the form of the injection function as long as a reasonable value of a = 0.2 is used. We illustrate the effects of perpendicular diffusion on the model solutions and discuss the viability of this process as a dominant mechanism by which SEPs are transported in longitude. Lastly, we try to quantity the effectiveness of perpendicular diffusion as an interplay between the magnitude of the relevant diffusion coefficient and the SEP intensity gradient driving the diffusion process. It follows that perpendicular diffusion is extremely effective early in an SEP event when large intensity gradients are present, while the effectiveness quickly decreases with time thereafter.

79 ASTRONOMY AND ASTROPHYSICS↗

Electronic measurement of microchannel plate pulse height distributions

Microchannel plates are a central component of the x-ray framing cameras used as analog imagers in many plasma experiment diagnostic systems. The microchannel plate serves as an amplifying element, increasing the electronic signal from incident radiation by factors of 10{sup 3}-10{sup 5}, with a broad pulse-height distribution. Seeking to optimize the photon-to-electron conversion efficiency and noise distribution of x-ray cameras, we will characterize the pulse-height distribution of the electron output from a single microchannel plate. Replacing the framing camera's phosphor-coated fiber optic screen with a charge-collection plate and coupling to a low-noise multichannel analyzer, we quantified the distribution in the total charge generated per photon event. The electronically measured pulse height distribution is used to estimate the signal-to-noise ratio of radiographic images from framing cameras.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Influence of rapid heating and cooling combined with deformation at ultrahigh strain rates on the microstructure evolution of pure titanium shaped charge liner

Highlights: • A slug prepared from pure titanium SCL was recovered after detonation deformation at an ultrahigh strain rate over 10{sup 5} s{sup −1}. • The α → β → α phase transformation occurred in Ti SCL during the ultrahigh-strain -rate deformation. • The microstructures of the recovered slug included lamellar α grains, equiaxed α grains, and jagged α grains. - Abstract: A slug prepared from pure titanium shaped charge liners was recovered after detonation deformation at an ultrahigh strain rate over 10{sup 5} s{sup −1} and high strain over 500%. Optical microscopy, electron backscattered diffraction (EBSD), and transmission electron microscopy (TEM) were employed to investigate the microstructure of the Ti shaped charged liner before and after the detonation deformation. The microstructures of the recovered slug include lamellar α grains, equiaxed α grains within localized shear bands, and jagged α grains. EBSD results indicated that the grain orientation distribution is random and no texture was observed in the slug. TEM observation revealed that the α → β → α phase transformation occurred owing to the rapid heating and cooling combined with deformation at ultrahigh strain rates in the Ti shaped charge liner. No melting phenomenon was observed during the deformation process. The deformation process consisted of the explosive detonation stage combined with rapid heating and the subsequent penetration stage combined with rapid cooling. In the explosive detonation stage, the α → β phase transformation instantaneously occurred via a martensitic mechanism. In the penetration stage, the high-temperature slug in β state was cooled rapidly and showed different deformation behaviors in three different areas.

36 MATERIALS SCIENCE↗

Effect of surface derived hydrocarbon impurities on Ar plasma properties

The authors report on Langmuir probe measurements that show that hydrocarbon surfaces in contact with Ar plasma cause changes of electron energy distribution functions due to the flux of hydrogen and carbon atoms released by the surfaces. The authors compare the impact on plasma properties of hydrocarbon species gasified from an etching hydrocarbon surface with injection of gaseous hydrocarbons into Ar plasma. They find that both kinds of hydrocarbon injections decrease electron density and slightly increase electron temperatures of low pressure Ar plasma. For low percentages of impurities (∼1% impurity in Ar plasma explored here), surface-derived hydrocarbon species and gas phase injected hydrocarbon molecules cause similar changes of plasma properties for the same number of hydrocarbon molecules injected into Ar with a decrease in electron density of ∼4%.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Electrostatic beams from tailored plasmas in a Penning-Malmberg trap

In recent work, a technique was developed to extract high quality beams from single-component plasmas confined in a Penning-Malmberg trap in a 4.8 T magnetic field. In this paper, a procedure is developed to extract these beams from the confining magnetic field and then focus them to create especially tailored electrostatic beams. Electron beams are extracted from the field in two stages: they are first transported to a region of reduced field (1 mT), and then taken to zero field with a nonadiabatic, fast extraction. Once in the field-free region, the beams are focused using an Einzel lens. Experimental results and numerical simulations are presented to illustrate the extraction and focusing process. Theoretical expressions are developed to describe the modifications to the relevant beam energy and spatial distributions. Where possible, analytic expressions are presented for the case relevant here of beams with Gaussian radial profiles. Beam emittance considerations are discussed as well as prospects for further development of these techniques. Application of these techniques to provide high-quality positron beams is also discussed.

43 PARTICLE ACCELERATORS↗

Modeling particle-induced electron emission in a simplified plasma Test Cell

Particle-induced electron emission (PIE) is modeled in a simplified, well-characterized plasma Test Cell operated at UCLA. In order for PIE to be a useful model in this environment, its governing equations are first reduced to lower-order models which can be implemented in a direct simulation Monte Carlo and Particle-in-Cell framework. These reduced-order models are described in full and presented as semi-empirical models. The models are implemented to analyze the interaction of low- and high-energy ({approx}1-2 keV) xenon ions and atoms with the stainless steel electrodes of the Test Cell in order to gain insight into the emission and transport of secondary electrons. Furthermore, there is a lack of data for xenon-stainless steel atom- and ion-surface interactions for similar environments. Using experimental data as a reference, both total yields and emitted electron energy distribution functions can be deduced by observing sensitivities of current collection results to these numerical models and their parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗