Overview of nuclear fragementation models and needs

It has been known for some time that adequate assessment of spacecraft requirements and concomitant estimates of astronaut radiation exposures from galactic cosmic radiation requires accurate, quantitative methods for characterizing these radiation fields as they pass through thick absorbers. The main nuclear interaction processes involved are nuclear elastic an inelastic collisions, and nuclear breakup (fragmentation) and electromagnetic dissociation (EMD). Nuclear fragmenation and EMD are important because they alter the elemental and isotopic composition of the transported radiation fields. At present, there is no suitable accurate theory for predicting nuclear fragmentation cross sections for all collision pairs and energies of interest in space radiation protection. Typical cross-section differences between theory and experiment range from about 25 percent to a factor of two. The resulting errors in transported flux, for high linear energy transfer (LET) particles, are compared to these cross-sections errors. In this overview, theoretical models of heavy ion fragmentation currently used to generate input data bases for cosmic-ray transport and shielding codes are reviewed. Their shortcomings are discussed. Further actions needed to improve their accuracy and generality are presented.

Townsend, L. W.↗

Overview of nuclear fragmentation models and needs

It has been known for some time that adequate assessment of spacecraft shield requirements and concomitant estimates of astronauts radiation exposures from galactic cosmic radiation requires accurate, quantitative methods for characterizing these radiation fields as they pass through thick absorbers. The main nuclear interaction processes involved are (1) nuclear elastic and inelastic collisions, and (2) nuclear breakup (fragmentation) and electromagnetic dissociation (EMD). Nuclear fragmentation and EMD are important because they alter the elemental and isotopic composition of the transported radiation fields. At present, there is no suitably accurate theory for predicting nuclear fragmentation cross sections for all collision pairs and energies of interest in space radiation protection. Typical cross-section differences between theory and experiment range from about 25 percent to a factor of two. The resulting errors in transported flux, for high linear energy transfer (LET) particles, are comparble to these cross-section errors. In this overview, theoretical models of heavy ion fragmentation currently used to generate input data bases for cosmic-ray transport and shielding codes are reviewed. Their shortcomings are discussed. Further actions needed to improve their accuracy and generality are presented.

Review↗

Root-Raised Cosine Filter Implementation That Uses Canonical Signed Digits for High-Speed Digital Filter Applications

NASA Lewis Research Center's Space Communications Division has been investigating high-speed digital filters that can operate at a higher speed than those in current use for a digital modulator and demodulator (modem). Using the Canonical Signed Digits (CSD) number representation for filter coefficients is a very effective way to increase the filter's speed while reducing complexity in the digital filter hardware design. This approach is a good alternative to using an expensive parallel-processing design technique or custom, application-specific integrated circuits. Such integrated circuits may not be suitable for applications that require filter speeds faster than what application-specific integrated circuits digital signal processors can offer for a dedicated channel. When a communication channel is a dedicated, multiplication process--a costly, time-consuming process--it can be greatly simplified by a replacement of the filter coefficients with CSD numbers. A computer code written with the MATLAB software package runs the program and generates CSD-represented filter coefficients that are based on minimizing minimum mean square errors. Also, the Alta Group of Cadence's Signal Processing Workstation is used to simulate and analyze the CSD filter responses. The impulse response of the root-raised cosine filter that is used as a base model is defined. From this filter, a set of coefficients is sampled and stored in a file. For the all coefficients, the optimal CSD number for each coefficient is searched on the basis of the minimum-mean-square-errors criterion. Because the distribution of CSD numbers is not uniform, quantization errors tend to be bigger for coefficients greater than 1/2. To offset errors that occur in a region of coefficients between 1/2 to 1 and to better represent fractions with CSD numbers, an extra nonzero digit is allowed for any coefficients exceeding 1/2. This will greatly improve frequency response as well as intersymbol interference at the receiver. The frequency response of a set of collected CSD-represented filter coefficients was compared with the same filter that was conventionally implemented. Analyses show CSD-implemented filters perform as well as conventional filters. Comparison of eye diagrams and bit-error-rate curves between CSD filters and traditionally implemented filters are almost indistinguishable. However, filter complexity was reduced from almost 3.5 to 1 for CSD filters. Complete computer simulation results are available. In the near future, work will focus on building actual working digital filter hardware in a field programmable gate array (FPGA).

Kim, Heechul↗

Lightning Charge Retrievals: Dimensional Reduction, LDAR Constraints, and a First Comparison with LIS Satellite Data

A "dimensional reduction" ("DR") method is introduced for analyzing lightning field changes ((Delta)Es) whereby the number of unknowns in a discrete two-charge model is reduced from the standard eight (x, y, z, Q, x', y', z', Q') to just four (x, y, z, Q). The four unknowns (x, y, z, Q) are found by performing a numerical minimization of a chi-square function. At each step of the minimization, an overdetermined fixed matrix (OFM) method is used to immediately retrieve the best "residual source" (x', y', z', Q'), given the values of (x, y, z, Q). In this way, all eight parameters Ix. y, z, Q, x', y', z', Q') are found, yet a numerical search of only four parameters (x, y, z, Q) is required. The DR method has been used to analyze lightning-caused (Delta)Es derived from multiple ground-based electric field measurements at the NASA Kennedy Space Center (KSC) and U.S. Air Force Eastern Range (ER). The accuracy of the DR method has been assessed by comparing retrievals with data provided by the lightning detection and ranging (LDAR) system at the KSC-ER. and from least squares error estimation theory, and the method is shown to be a useful "stand alone" charge retrieval tool. Since more than one charge distribution describes a finite set of (Delta)Es (i.e., solutions are nonunique), and since there can be appreciable differences in the physical characteristics of these solutions, not all DR solutions are physically acceptable. Hence. an alternative and more accurate method of analysis is introduced that uses LDAR data to constrain the geometry of the charge solutions. thereby removing physically unacceptable retrievals. The charge solutions derived from this method are shown to compare well with independent satellite- and ground-based observations of lightning m several Florida storms.

Koshak, W. J.↗

EnKF OSSE Experiments Assessing the Impact of HIRAD Wind Speed and HIWRAP Radial Velocity Data on Analysis of Hurricane Karl (2010)

Previous studies (e.g., Zhang et al. 2009, Weng et al. 2011) have shown that radial velocity data from airborne and ground-based radars can be assimilated into ensemble Kalman filter (EnKF) systems to produce accurate analyses of tropical cyclone vortices, which can reduce forecast intensity error. Recently, wind speed data from SFMR technology has also been assimilated into the same types of systems and has been shown to improve the forecast intensity of mature tropical cyclones. Two instruments that measure these properties were present during the NASA Genesis and Rapid Intensification Processes (GRIP) field experiment in 2010 which sampled Hurricane Karl, and will next be co-located on the same aircraft for the subsequent NASA HS3 experiment. The High Altitude Wind and Rain Profiling Radar (HIWRAP) is a conically scanning Doppler radar mounted upon NASAs Global Hawk unmanned aerial vehicle, and the usefulness of its radial velocity data for assimilation has not been previously examined. Since the radar scans from above with a fairly large fixed elevation angle, it observes a large component of the vertical wind, which could degrade EnKF analyses compared to analyses with data taken from lesser elevation angles. The NASA Hurricane Imaging Radiometer (HIRAD) is a passive microwave radiometer similar to SFMR, and measures emissivity and retrieves hurricane surface wind speeds and rain rates over a much wider swath. Thus, this study examines the impact of assimilating simulated HIWRAP radial velocity data into an EnKF system, simulated HIRAD wind speed, and HIWRAP+HIRAD with the Weather Research and Forecasting (WRF) model and compares the results to no data assimilation and also to the Truth from which the data was simulated for both instruments.

Albers, Cerese↗

The New Sun-Sky-Lunar Cimel CE318-T Multiband Photometer - A Comprehensive Performance Evaluation

This paper presents the new photometer CE318-T, able to perform daytime and night-time photometric measurements using the sun and the moon as light source. Therefore,this new device permits a complete cycle of diurnal aerosol and water vapour measurements valuable to enhance atmospheric monitoring to be extracted. In this study wehave found significantly higher precision of triplets when comparing the CE318-T master instrument and the Cimel AErosol RObotic NET work (AERONET) master (CE318-AERONET) triplets as a result of the new CE318-T tracking system. Regarding the instrument calibration, two new methodologies to transfer the calibration from a reference instrument using only daytime measurements (Sun Ratio and Sun-Moon gain factor techniques) are presented and discussed. These methods allow the reduction of the previous complexities inherent to nocturnal calibration. A quantitative estimation of CE318-T AOD uncertainty by means of error propagation theory during daytime revealed AOD uncertainties (u(sup D)(sub AOD)) for Langley-calibrated instruments similar to the expected values for other reference instruments (0.002-0.009). We have also found u(sup D)(sub AOD) values similar to the values reported in sun photometry for field instruments (approximately 0.015). In the case of the night-time period, the CE318-T-estimated standard combined uncertainty (u(sup N)(sub AOD)) is dependent not only on the calibration technique but also on illumination conditions and the instrumental noise. These values range from 0.011-0.018 for Lunar Langley-calibrated instruments to 0.012-0.021 for instruments calibrated using the Sun Ratio technique. In the case of moon-calibrated instruments using the Sun-Moon gain factor method and sun calibrated using the Langley technique, we found u(sup N)(sub AOD) ranging from 0.016 to 0.017 (up to 0.019 in 440 nm channel), not dependent on any lunar irradiance model. A subsequent performance evaluation including CE318-T and collocated measurements from independent reference instruments has served to assess the CE318-T performance as well as to confirm its estimated uncertainty. Daytime AOD evaluation, performed at Izana station from March to June 2014, encompassed measurements from a reference CE318-T, a CE318-AERONET master instrument, a Precision Filter Radiometer (PFR) and a Precision Spectroradiometer (PSR) prototype, reporting low AOD discrepancies between the four instruments (up to 0.006). The nocturnal AOD evaluation was performed using CE318-T- and starphotometer-collocated measurements and also by means of a day/night coherence transition test using the CE318-T master instrument and the CE318 daytime data from the CE318-AERONET master instrument. Results showed low discrepancies with the star photometer at 870 and 500 nm channels(less tna or equal to 0.013) and differences with AERONET daytime data (1 h after and before sunset and sunrise) in agreement with the estimated u(sup N)(sub AOD) values at all illumination conditions in the case of channels within the visible spectral range, and only for high moon's illumination conditions in the case of near infrared channels. Perceptible water vapour (PWV) validation showed a good agreement between CE318-T and Global Navigation Satellite System (GNSS) PWV values for all illumination conditions, within the expected precision for sun photometry. Finally, two case studies have been included to highlight the ability of the new CE318-T to capture the diurnal cycle of aerosols and water vapour as well as short-term atmospheric variations, critical for climate studies.

Barreto, Africa↗

WFIRST CGI: Prism and Polarizer Characterization Modes

As part of its technology demonstration, the WFIRST coronagraph instrument (CGI) will demonstrate point source spectroscopy and polarization measurements of disks. The specific implementation of spectroscopy is a zero-deviation Amici prism and slit to be placed on the planet after high contrast has been achieved by CGI. The polarization optics are a set of Wollaston prisms so that orthogonal polarization states can be measured simultaneously. The CGI spectral characterization mode, being designed and built and Goddard Space Flight Center (GSFC), has a spectral resolution of R50 and is designed to accommodate a 15% bandpass spanning 610-785nm. In order to recover Stokes information, there are two sets of Wollaston prisms clocked 45 degrees with respect to one another with each measurement taken in series. The Wollaston design and optical elements are a contribution by the Japanese Aerospace Exploration Agency, with final alignment and testing being done at GSFC. The spectroscopy mode is designed to target Methane absorption features around 730nm, keeping the spectral resolution as low as possible to improve the signal-to-noise ratio and hence reduce detection time. We highlight the requirements for these modes and address the challenge of on-orbit spectral calibration for a deployable slit in the presence of pointing drifts. Of unique interest is how the observatory error budget couples into good stellar spectrum calibration and subsequent speckle subtraction. We also provide further detail on the optomechanical design, its stability based on thermal and structural predictions, modeled performance, and operations concept. These performance metrics are simulated to demonstrate how a slit located at an arbitrary field point is homed onto the planet and converted to a calibrated spectrum.

Tyler D Groff↗

Effects of Mild Hypobaric Hypoxia on Visual Field Impairment

INTRODUCTION: The primary objective of the Exploration Atmosphere (EA) study is to validate a new prebreathe protocol necessary before exposure to a suited hypobaric environment during extravehicular activity (EVA) from a habitat ‘exploration atmosphere’ of 56.5kPa (8.2 psia), 34% O2, 66% N2. Prebreathe protocols must be time and resource efficient while also controlling Decompression Sickness (DCS) risk to within acceptable limits. The habitat hypobaric exploration atmosphere also results in a mildly hypoxic environment (piO2 = 128mmHg). As a secondary objective of the EA study, we characterized the effects of 11-day exposure to a mild hypobaric hypoxic environment on visual performance. METHODS: Two, 11-day hypobaric chamber tests were performed (EA-1and EA-2, n=8 each) in NASA’s 20-foot chamber at Johnson Space Center where subjects lived in the exploration atmosphere. Subjects also underwent simulated 6-hour EVAs at 85% O2 and 29.6 kPa during EVA on days 3, 5, 7, 9, and 11. Visual acuity (VA), a measure of spatial resolution, and contrast sensitivity (CS), a measure of ability to distinguish ever finer increments of brightness, were assessed on non-EVA days by using gapped Landolt C testing. The luminance was controlled by using a booth, a light monitor, and a lighting rheostat. EA-1 data had revealed problems in lighting control impacting consistency of the data. Procedures were subsequently updated for the EA-2 test. RESULTS: EA-1 data revealed large variance and data recording errors and was removed from the analysis. One participant left the study at Test Day 3 during EA-2. EA-2 ANOVA results showed CS (mean change=0.010 logCSWeber) and VA (mean change, -0.016 logMAR) between pre-test and 11-day test phases; however, neither VA nor CS changes were statistically significant. There were non-statistically significant declines in VA across test phases. DISCUSSION: Overall, visual field performance did not exhibit clinically significant changes (3 lines or greater change in LogMar chart) during exposure to the mild hypoxic exploration atmosphere environment compared to pre-test baseline. The consistency and stability of VA data during EA-2 suggests that the mild hypobaric hypoxic environment did not cause clinically significant negative impacts to participants’ visual field performance.

Visual Acuity↗

Effects of Mild Hypobaric Hypoxia on Visual Field Impairment

INTRODUCTION: The primary objective of the Exploration Atmosphere (EA) study is to validate a new prebreathe protocol necessary before exposure to a suited hypobaric environment during extravehicular activity (EVA) from a habitat ‘exploration atmosphere’ of 56.5kPa (8.2 psia), 34% O2, 66% N2. Prebreathe protocols must be time and resource efficient while also controlling Decompression Sickness (DCS) risk to within acceptable limits. The habitat hypobaric exploration atmosphere also results in a mildly hypoxic environment (piO2 = 128mmHg). As a secondary objective of the EA study, we characterized the effects of 11-day exposure to a mild hypobaric hypoxic environment on visual performance. METHODS: Two, 11-day hypobaric chamber tests were performed (EA-1and EA-2, n=8 each) in NASA’s 20-foot chamber at Johnson Space Center where subjects lived in the exploration atmosphere. Subjects also underwent simulated 6-hour EVAs at 85% O2 and 29.6 kPa during EVA on days 3, 5, 7, 9, and 11. Visual acuity (VA), a measure of spatial resolution, and contrast sensitivity (CS), a measure of ability to distinguish ever finer increments of brightness, were assessed on non-EVA days by using gapped Landolt C testing. The luminance was controlled by using a booth, a light monitor, and a lighting rheostat. EA-1 data had revealed problems in lighting control impacting consistency of the data. Procedures were subsequently updated for the EA-2 test. RESULTS: EA-1 data revealed large variance and data recording errors and was removed from the analysis. One participant left the study at Test Day 3 during EA-2. EA-2 ANOVA results showed CS (mean change=0.010 logCSWeber) and VA (mean change, -0.016 logMAR) between pre-test and 11-day test phases; however, neither VA nor CS changes were statistically significant. There were non-statistically significant declines in VA across test phases. DISCUSSION: Overall, visual field performance did not exhibit clinically significant changes (3 lines or greater change in LogMar chart) during exposure to the mild hypoxic exploration atmosphere environment compared to pre-test baseline. The consistency and stability of VA data during EA-2 suggests that the mild hypobaric hypoxic environment did not cause clinically significant negative impacts to participants’ visual field performance.

Visual Acuity↗

Evaluation of one-dimensional approximations for radiative transport in blunt body shock layers

One-dimensional approximations for the nongray radiative flux and flux divergence in radiating shock layers about a blunt entry body are compared with an exact three-dimensional treatment. A coupled radiative-gasdynamic analysis of the shock layer flow about the entire body provided the thermodynamic field used in these comparisons. In terms of calculating the total energy lost by the shock layer, the one-dimensional approximations to the radiative flux divergence are accurate to within a few percent. In terms of calculating the surface flux, the one-dimensional approximations introduce the largest errors of approximately 15 percent near the stagnation point. The source of these errors is the slab-like geometric representation of the shock layer inherent in all one-dimensional models. Finally, for both the radiative flux and its divergence, the tangent slab approximation provides more accurate results than differential approximation methods.

Wilson, K. H.↗

Far-field multimodal acoustic radiation directivity

A comparison is made between approximate equations for far-field acoustic radiation patterns and exact equations for single and multimodal excitations in order to determine the validity range for the approximate approach. It is found that for single-mode cases: (1) the gross behavior of the primary lobes is adequately described by the approximate equations, (2) some error is found for lower and zero radial order modes, and (3) some agreement is yielded between exact and approximate sidelobes, although the approximate equation was not intended to simulate sidelobes. Multimodal approximate equations are compared to exact equations for various distributions of modal power; for all cases excellent agreement is found. For multimodal patterns it is noted that many modes influence the final level and shape of the directivity curve, although the major contributions are from the higher radial order modes.

Saule, A. V.↗

High-speed communication detector characterization by bit error rate measurements

Performance data taken on several candidate high data rate laser communications photodetectors is presented. Measurements of bit error rate versus signal level were made in both a 1064 nm system at 400 Mbps and a 532 nm system at 500 Mbps. RCA silicon avalanche photodiodes are superior at 1064 nm, but the Rockwell hybrid 3-5 avalanche photodiode preamplifiers offer potentially superior performance. Varian dynamic crossed field photomultipliers are superior at 532 nm, however, the RCA silicon avalanche photodiode is a close contender.

Green, S. I.↗

Two probable optical flashes from gamma-ray bursters

Two images on archival photographic plates which are most likely records of optical flashes from gamma-ray bursters (GRBs) were examined. One of these images appears on a 1901 plate in the field of the 5 Nov. 1979 GRB, while the other is in the field of the 13 Jan. 1979 GRB on a plate exposed in 1944. The 1901 optical transient image is circular in shape, while all normal star images are trailed by 8 in. No optical transients are found in a control region which is 34.3 times larger than the GRB error regions examined. Independent limits on the optical flash rate from the sky yield a probability of less than 0.0001 that any one of the optical transients is due to a background flash. A total exposure of 2.7 years was examined for GRB flashes at known GRB locations on the Harvard plates and a total of three GRB flashes were seen, that the average recurrence time scale for optical flashes is roughly one year. The optical fluence of these optical flashes was measured. For the three currently known GRB optical flashes, the ratio of gamma-ray fluence (from a modern burst) to the optical fluence (from a archival burst) were measured to be 800, 900, and 900.

Schaefer, B. E.↗

Two probable optical flashes from gamma-ray bursters

Two images on archival photographic plates which are most likely records of optical flashes from gamma-ray bursters (GRBs) were examined. One of these images appears on a 1901 plate in the field of the Nov. 5, 1979 GRB, while the other is in the field of the Jan. 13, 1979 GRB on a plate exposed in 1944. The 1901 optical transient image is circular in shape, while all normal star images are trailed by 8 in. No optical transients are found in a control region which is 34.3 times larger than the GRB error regions examined. Independent limits on the optical flash rate from the sky yield a probability of less than 0.0001 that any one of the optical transients is due to a background flash. A total exposure of 2.7 years was examined for GRB flashes at known GRB locations on the Harvard plates and a total of three GRB flashes were seen, that the average recurrence time scale for optical flashes is roughly one year. The optical fluence of these optical flashes was measured. For the three currently known GRB optical flashes, the ratio of gamma-ray fluence (from a modern burst) to the optical fluence (from a archival burst) were measured to be 800, 900, and 900.

Schaefer, B. E.↗

Modeling issues in precision orbit determination for Mars orbiter

This paper examines the accuracy of recent Mars gravity models and the importance of perturbations due to the Mars radiation pressure and the Martian moons, Phobos and Deimos, on the trajectories of Mars orbiters. A linear orbit perturbation theory is used to characterize the patterns of gravity field near resonances for the Viking and Mariner 9 spacecraft. These resonances are shown to have considerable power and their potential for contributing to Mars gravity solutions is emphasized. It is shown that some of the same resonance orders which appear in the Viking orbits, dominate the radial orbit error spectrum for Mars Observer. Results of orbit determination simulations at the Goddard Space Flight Center show that the perturbations caused by the Martian moons and the Mars radiation pressure are larger than 0.1 mm/s, the expected precision of the Mars Observer Doppler tracking data. Tests with the Viking Doppler data indicate that best analysis of these data mandates the inclusion of the Phobos gravitational perturbation in the modeling of Viking spacecraft trajectories.

Lemoine, Frank G.↗

Radiometer system requirements for microwave remote sensing from satellites

An area of increasing interest is the establishment of a significant research program in microwave remote sensing from satellites, particularly geosynchronous satellites. Due to the relatively small resolution cell sizes, a severe requirement is placed on beam efficiency specifications for the radiometer antenna. Geostationary satellite microwave radiometers could continuously monitor several important geophysical parameters over the world's oceans. These parameters include the columnar content of atmospheric liquid water (both cloud and rain) and water vapor, air temperature profiles, and possibly sea surface temperature. Two principle features of performance are of concern. The first is the ability of the radiometer system to resolve absolute temperatures with a very small absolute error, a capability that depends on radiometer system stability, on frequency bandwidth, and on footprint dwell time. The second is the ability of the radiometer to resolve changes in temperature from one resolution cell to the next when these temperatures are subject to wide variation over the overall field-of-view of the instrument. Both of these features are involved in the use of the radiometer data to construct high-resolution temperature maps with high absolute accuracy.

Juang, Jeng-Nan↗

Logic Design Pathology and Space Flight Electronics

Logic design errors have been observed in space flight missions and the final stages of ground test. The technologies used by designers and their design/analysis methodologies will be analyzed. This will give insight to the root causes of the failures. These technologies include discrete integrated circuit based systems, systems based on field and mask programmable logic, and the use computer aided engineering (CAE) systems. State-of-the-art (SOTA) design tools and methodologies will be analyzed with respect to high-reliability spacecraft design and potential pitfalls are discussed. Case studies of faults from large expensive programs to "smaller, faster, cheaper" missions will be used to explore the fundamental reasons for logic design problems.

Katz, Richard↗

XTE J1908+094

Goddard Space Flight Center reports the serendipitous discovery of a new x-ray transient, XTE J1908+094, in RXTE (Rossi X-ray Timing Explorer) PCA (Proportional Counter Array) observations of the soft-gamma-ray repeater SGR 1900+14, triggered following the burst activity on Feb. 17-18 (GCN 1253). These observations failed to detect the 5.2-s SGR pulsations, pointing towards a possible new source as the origin of the high x-ray flux. An RXTE PCA scan of the region around SGR 1900+14 on Feb. 21 was consistent with emission only from known sources (and no new sources). However, the scans required SGR 1900+14 to be 20 times brighter than its quiescent flux level (GCN 1256). A Director's Discretionary Time Chandra observation on Mar. 11 showed that the SGR was quiescent and did not reveal any new source within the Chandra ACIS (Advanced CCD (charge coupled device) Imaging Spectrometer) field-of-view. A subsequent RXTE PCA scan on Mar. 17, taken in combination with the first scan, required that a new source be included in the fit. The best-fit position is R.A. 19h 08m 50s, Decl. = +9 22 deg .5 (equinox J2000.0; estimated 2 deg systematic error radius), or approximately 24 deg away from the SGR source. The source spectrum (2-30 kev) can be best fit with a power-law function including photoelectric absorption (column density N_h = 2.3 x 10(exp 22), photon index = 1.55). Iron line emission is present, but may be due to the Galactic ridge. Between Feb. 19 and Mar. 17, the source flux (2-10 keV) has risen from 26 to 64 mCrab. The power spectrum is flat between 1 mHz and 0.1 Hz, falling approximately as 1/f**0.5 up to 1 Hz. At 1 Hz is seen a broad quasiperiodic oscillation peak and a break to a 1/f**2 power law, which continues to 4 Hz. The fractional rms (root mean square) amplitude from 1 mHz to 4 Hz is 43 percent. No coherent pulsations are seen between 0.001 and 1024 Hz. The authors conclude that XTE J1908+094 is a new blackhole candidate.