At least 1,639 records · Page 91

Triple-Error-Correcting Codec ASIC

Coder/decoder constructed on single integrated-circuit chip. Handles data in variety of formats at rates up to 300 Mbps, correcting up to 3 errors per data block of 256 to 512 bits. Helps reduce cost of transmitting data. Useful in many high-data-rate, bandwidth-limited communication systems such as; personal communication networks, cellular telephone networks, satellite communication systems, high-speed computing networks, broadcasting, and high-reliability data-communication links.

Jones, Robert E.↗

Modeling Subsurface Explosions Recorded on a Distributed Fiber Optic Sensor

Fiber optic distributed acoustic sensors (DAS) are becoming a widely used tool for seismic sensing. Here we examine recordings of two subsurface chemical explosions, DAG-1 and DAG-3, each of which was about one metric ton (TNT equivalent), that were recorded from a helical fiber installed in two boreholes 80 m away from the source location. Several clear phases including the initial P wave, a weak S wave, and a surface reflected P wave are observed on the helical DAS data. We estimate a velocity model using arrival times measured from the fiber. The DAS waveform data were compared with colocated accelerometers at specific depths in both frequency and time domains. Furthermore, the spectra of the DAS data matched spectra estimated from the accelerometer records. Comparisons of observed waveform shape between the accelerometer records and the fiber measurements (strain-rate) show reasonable agreement except for the data near the event depth. The DAS data and the accelerometer agreed in relative amplitudes but we had difficulties in matching absolute amplitudes, possibly due to errors in metadata. Synthetic strain-rate waveforms were calculated using a 2D wavenumber algorithm and matched the waveform shape and relative amplitudes. In general, DAS is effective at recording strong ground motions at high spatial density. Comparison of the synthetic seismograms with observed data indicate that the waveforms are not consistent with a pure isotropic explosion source and that the observed S waves originate from very near the source region.

58 GEOSCIENCES↗

Reliable and redundant FPGA based read-out design in the ATLAS TileCal Demonstrator

The Tile Calorimeter at ATLAS [1] is a hadron calorimeter based on steel plates and scintillating tiles read out by PMTs. The current read-out system uses standard ADCs and custom ASICs to digitize and temporarily store the data on the detector. However, only a subset of the data is actually read out to the counting room. The on-detector electronics will be replaced around 2023. To achieve the required reliability the upgraded system will be highly redundant. Here the ASICs will be replaced with Kintex-7 FPGAs from Xilinx. This, in addition to the use of multiple 10 Gbps optical read-out links, will allow a full read-out of all detector data. Due to the higher radiation levels expected when the beam luminosity is increased, opportunities for repairs will be less frequent. The circuitry and firmware must therefore be designed for sufficiently high reliability using redundancy and radiation tolerant components. Within a year, a hybrid demonstrator including the new readout system will be installed in one slice of the ATLAS Tile Calorimeter. This will allow the proposed upgrade to be thoroughly evaluated well before the planned 2023 deployment in all slices, especially with regard to long term reliability. Different firmware strategies alongside with their integration in the demonstrator are presented in the context of high reliability protection against hardware malfunction and radiation induced errors.

ATLAS↗

Protograph LDPC Codes with Node Degrees at Least 3

In this paper we present protograph codes with a small number of degree-3 nodes and one high degree node. The iterative decoding threshold for proposed rate 1/2 codes are lower, by about 0.2 dB, than the best known irregular LDPC codes with degree at least 3. The main motivation is to gain linear minimum distance to achieve low error floor. Also to construct rate-compatible protograph-based LDPC codes for fixed block length that simultaneously achieves low iterative decoding threshold and linear minimum distance. We start with a rate 1/2 protograph LDPC code with degree-3 nodes and one high degree node. Higher rate codes are obtained by connecting check nodes with degree-2 non-transmitted nodes. This is equivalent to constraint combining in the protograph. The condition where all constraints are combined corresponds to the highest rate code. This constraint must be connected to nodes of degree at least three for the graph to have linear minimum distance. Thus having node degree at least 3 for rate 1/2 guarantees linear minimum distance property to be preserved for higher rates. Through examples we show that the iterative decoding threshold as low as 0.544 dB can be achieved for small protographs with node degrees at least three. A family of low- to high-rate codes with minimum distance linearly increasing in block size and with capacity-approaching performance thresholds is presented. FPGA simulation results for a few example codes show that the proposed codes perform as predicted.

low density parity check (LDPC)↗

Dynamical predictability in a simple general circulation model - Average error growth

Average predictability and error growth in a simple realistic two-level general circulation model (GCM) were investigated using a series of Monte Carlo experiments for fixed external forcing (perpetual winter in the Northern Hemisphere). It was found that, for realistic initial errors, the dependence of the limit of dynamic predictability on total wavenumber was similar to that found for the ECMWF model for the 1980/1981 winter conditions, with the lowest wavenumbers showing significant skill for forecast ranges of more than 1 month. On the other hand, for very small amplitude errors distributed according to the climate spectrum, the total error growth was superexponential, reaching a maximum growth rate (2-day doubling time) in about 1 week. A simple empirical model of error variance, which involved two broad wavenumber bands and incorporating a 3/2 power saturation term, was found to provide an excellent fit to the GCM error growth behavior.

Schubert, Siegfried D.↗

Probabilistic Processing of Asynchronous Geiger-Mode Avalanche Photodiode Arrays for Background Rate Measurements

A system-level performance evaluation of Geiger-mode avalanche photodiode (GmAPD) arrays requires accurate measurement and prediction of the background rate of the device due to dark counts and other spurious detection events. Since a GmAPD detector reports only a binary value and timestamp associated with an avalanche event, dark count rates are typically measured by averaging thousands of frames to support a statistically significant measurement. For both synchronous and asynchronous detector, the Poisson distributed background rates are referenced to the time each pixel is armed. Unlike for synchronous GmAPD imagers where all the pixels are armed to an array-wide arm signal, an asynchronous pixel operates independently from its neighboring pixels; requiring the background rates to be calculated using an interarrival histogram. For both types of imagers, the background rate is typically evaluated by fitting an exponential distribution to a fixed window within a measured histogram of time intervals between detection events However, if the statistics of the background rate are insufficient – whether that is due to low population sizes, saturation, or a large dynamic range of population size across the array, the pixel, or array-wide, performance metrics may report results with varying accuracy. This paper reports on an implementation of an algorithm that evaluates GmAPD background rates based on statistical metrics rather than fixed windows. The algorithm functions by determining the appropriate integration window within the interarrival time histogram based on a per-pixel count rate set by a predetermined tolerable measurement error. The implementation of the algorithm allows us to characterize GmAPD arrays with orders of magnitude spread in background rates across the detector using common statistical parameters.

Mumolo, J.↗

Bursty channel errors and the Viterbi decoder

Recent applications have developed for spread spectrum communications, hardware data transfer, high rate digital systems, etc. that use channels for which errors tend to occur in short bursts in addition to those at random, i.e., compound channels. Viterbi decoding algorithms are generally very good for random error channels but are not as efficient for burst errors or for compound channels. This paper presents the results of a computer simulation study of the performance of various Viterbi decoders when receiving data corrupted with burst and random errors on the same channel. Simulations were performed using hard-decision CPSK.

Ingels, F.↗

Analysis of Potassium in Bricks--Determining the Dose Rate from {sup 40}K for Thermoluminescence Dating

Thermoluminescence (TL) dating is based on accumulating the natural radiation dose in the material of a dated artefact (brick, pottery, etc.), and comparing the dose accumulated during the lifetime of the object with the dose rate within the sample collected for TL measurement. Determining the dose rate from natural radionuclides in materials is one of the most important and most difficult parts of the technique. The most important radionuclides present are usually nuclides of the uranium and thorium decay series and {sup 40}K. An analysis of the total potassium concentration enables us to determine the {sup 40}K content effectively, and from this it is possible to calculate the dose rate originating from this radiation source. X-ray fluorescence (XRF) analysis can be used to determine the potassium concentration in bricks rapidly and efficiently. The procedure for analysing potassium, examples of results of dose rate calculation and possible sources of error are described here.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Rate constant for the fraction of atomic chlorine with formaldehyde from 200 to 500K

A flash photolysis - resonance fluorescence technique was used to measure rate constant. The results were independent of substantial variations in H2CO, total pressure (Ar), and flash intensity (i.e., initial Cl). The rate constant was shown to be invariant with temperature, the best representation for this temperature range being K = (7.48 + or - 0.50) x 10 to the minus 11 power cu cm molecule-1 s-1 where the error is one standard deviation. The rate constant is theoretically discussed and the potential importance of the reaction in stratospheric chemistry is considered.

Michael, J. V.↗

Secular variation of activity in comets 2P/Encke and 9P/Tempel 1

We compare production rates of H20 derived from International Ultraviolet Explorer (IUE) spectra from multiple apparitions of 2 comets, 2P/Encke and 9P/Tempel 1, whose orbits are in near-resonance with that of the Earth. Since model-induced errors are primarily a function of observing geometry, the close geometrical matches afforded by the resonance condition results in the cancellation of such errors when taking ratios of production rates. Giving careful attention to the variation of model parameters with solar activity, we find marginal evidence of change in 2P/Encke: a 1-sigma pre-perihelion decrease averaging 4%/revolution over 4 apparitions from 1980-1994, and a 1-sigma post-perihelion increase of 16%/revolution for 2 successive apparitions in 1984 and 1987. We find for 9P/Tempel 1, however, a 7-sigma decrease of 29%/revolution over 3 apparitions from 1983-1994, even after correcting for a tracking problem which made the fluxes systematically low. We speculate on a possible association of the character of long-term brightness variations with physical properties of the nucleus, and discuss implications for future research.

Haken, Michael↗

Accurate Magnetometer/Gyroscope Attitudes Using a Filter with Correlated Sensor Noise

Magnetometers and gyroscopes have been shown to provide very accurate attitudes for a variety of spacecraft. These results have been obtained, however, using a batch-least-squares algorithm and long periods of data. For use in onboard applications, attitudes are best determined using sequential estimators such as the Kalman filter. When a filter is used to determine attitudes using magnetometer and gyroscope data for input, the resulting accuracy is limited by both the sensor accuracies and errors inherent in the Earth magnetic field model. The Kalman filter accounts for the random component by modeling the magnetometer and gyroscope errors as white noise processes. However, even when these tuning parameters are physically realistic, the rate biases (included in the state vector) have been found to show systematic oscillations. These are attributed to the field model errors. If the gyroscope noise is sufficiently small, the tuned filter 'memory' will be long compared to the orbital period. In this case, the variations in the rate bias induced by field model errors are substantially reduced. Mistuning the filter to have a short memory time leads to strongly oscillating rate biases and increased attitude errors. To reduce the effect of the magnetic field model errors, these errors are estimated within the filter and used to correct the reference model. An exponentially-correlated noise model is used to represent the filter estimate of the systematic error. Results from several test cases using in-flight data from the Compton Gamma Ray Observatory are presented. These tests emphasize magnetometer errors, but the method is generally applicable to any sensor subject to a combination of random and systematic noise.

Sedlak, J.↗

A simulator study of the interaction of pilot workload with errors, vigilance, and decisions

A full mission simulation of a civil air transport scenario that had two levels of workload was used to observe the actions of the crews and the basic aircraft parameters and to record heart rates. The results showed that the number of errors was very variable among crews but the mean increased in the higher workload case. The increase in errors was not related to rise in heart rate but was associated with vigilance times as well as the days since the last flight. The recorded data also made it possible to investigate decision time and decision order. These also varied among crews and seemed related to the ability of captains to manage the resources available to them on the flight deck.

Smith, H. P. R.↗

Angle-dependent strong-field molecular ionization rates with tuned range-separated time-dependent density functional theory

Strong-field ionization and the resulting electronic dynamics are important for a range of processes such as high harmonic generation, photodamage, charge resonance enhanced ionization, and ionization-triggered charge migration. Modeling ionization dynamics in molecular systems from first-principles can be challenging due to the large spatial extent of the wavefunction which stresses the accuracy of basis sets, and the intense fields which require non-perturbative time-dependent electronic structure methods. In this paper, we develop a time-dependent density functional theory approach which uses a Gaussian-type orbital (GTO) basis set to capture strong-field ionization rates and dynamics in atoms and small molecules. This involves propagating the electronic density matrix in time with a time-dependent laser potential and a spatial non-Hermitian complex absorbing potential which is projected onto an atom-centered basis set to remove ionized charge from the simulation. For the density functional theory (DFT) functional we use a tuned range-separated functional LC-PBE*, which has the correct asymptotic 1/r form of the potential and a reduced delocalization error compared to traditional DFT functionals. Ionization rates are computed for hydrogen, molecular nitrogen, and iodoacetylene under various field frequencies, intensities, and polarizations (angle-dependent ionization), and the results are shown to quantitatively agree with time-dependent Schrödinger equation and strong-field approximation calculations. This tuned DFT with GTO method opens the door to predictive all-electron time-dependent density functional theory simulations of ionization and ionization-triggered dynamics in molecular systems using tuned range-separated hybrid functionals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simulation of the Universal-Time Diurnal Variation of the Global Electric Circuit Charging Rate

A global lightning model that includes diurnal and annual lightning variation, and total flash density versus latitude for each major land and ocean, has been used as the basis for simulating the global electric circuit charging rate. A particular objective has been to reconcile the difference in amplitude ratios [AR=(max-min)/mean] between global lightning diurnal variation (AR approximately equals 0.8) and the diurnal variation of typical atmospheric potential gradient curves (AR approximately equals 0.35). A constraint on the simulation is that the annual mean charging current should be about 1000 A. The global lightning model shows that negative ground flashes can contribute, at most, about 10-15% of the required current. For the purpose of the charging rate simulation, it was assumed that each ground flash contributes 5 C to the charging process. It was necessary to assume that all electrified clouds contribute to charging by means other than lightning, that the total flash rate can serve as an indirect indicator of the rate of charge transfer, and that oceanic electrified clouds contribute to charging even though they are relatively inefficient in producing lightning. It was also found necessary to add a diurnally invariant charging current component. By trial and error it was found that charging rate diurnal variation curves could be produced with amplitude ratios and general shapes similar to those of the potential gradient diurnal variation curves measured over ocean and arctic regions during voyages of the Carnegie Institute research vessels. The comparisons were made for the northern winter (Nov.-Feb.), the equinox (Mar., Apr., Sept., Oct.), the northern summer (May-Aug.), and the whole year.

Mackerras, David↗

Simulation of the Universal-Time Diurnal Variation of the Global Electric Circuit Charging Rate

A global lightning model that includes diurnal and annual lightning variation, and total flash density versus latitude for each major land and ocean, has been used as the basis for simulating the global electric circuit charging rate. A particular objective has been to reconcile the difference in amplitude ratios [AR=(max-min)/mean] between global lightning diurnal variation (AR approx. = 0.8) and the diurnal variation of typical atmospheric potential gradient curves (AR approx. = 0.35). A constraint on the simulation is that the annual mean charging current should be about 1000 A. The global lightning model shows that negative ground flashes can contribute, at most, about 10-15% of the required current. For the purpose of the charging rate simulation, it was assumed that each ground flash contributes 5 C to the charging process. It was necessary to assume that all electrified clouds contribute to charging by means other than lightning, that the total flash rate can serve as an indirect indicator of the rate of charge transfer, and that oceanic electrified clouds contribute to charging even though they are relatively inefficient in producing lightning. It was also found necessary to add a diurnally invariant charging current component. By trial and error it was found that charging rate diurnal variation curves in Universal time (UT) could be produced with amplitude ratios and general shapes similar to those of the potential gradient diurnal variation curves measured over ocean and arctic regions during voyages of the Carnegie Institute research vessels.

Mackerras, D.↗

Sampling error study for rainfall estimate by satellite using a stochastic model

In a parameter study of satellite orbits, sampling errors of area-time averaged rain rate due to temporal sampling by satellites were estimated. The sampling characteristics were studied by accounting for the varying visiting intervals and varying fractions of averaging area on each visit as a function of the latitude of the grid box for a range of satellite orbital parameters. The sampling errors were estimated by a simple model based on the first-order Markov process of the time series of area averaged rain rates. For a satellite of nominal Tropical Rainfall Measuring Mission (Thiele, 1987) carrying an ideal scanning microwave radiometer for precipitation measurements, it is found that sampling error would be about 8 to 12 pct of estimated monthly mean rates over a grid box of 5 X 5 degrees. It is suggested that an observation system based on a low inclination satellite combined with a sunsynchronous satellite simultaneously might be the best candidate for making precipitation measurements from space.

Shin, Kyung-Sup↗

A Simple, Velocity Dependent, Collision Probability Algorithm for Small Combined Hard Body Radii Close Approach Events

Over the last few years progress has been made in the velocity dependent collision probability problem. Recent progress in this problem has been approached via integration of the probability flux into the surface of the combined hard body object. The algorithm presented uses the surface flux approach and is designed to compute the collision probability rate between two objects given their time dependent states and state error covariance matrices. With regards to the computation of the collision probability (Pc) rate, two major differences exist between the development of this algorithm and the usual Pc algorithm. First, the shape of the at-risk volume is assumed to be a cube rather than a sphere. The size of the cube is chosen so that it circumscribes the usual hard body sphere chosen for the spherical Pc problem. This will result in half the length of a side of the cube being equal to the hard body radius (HBR) of the sphere. Second, it is assumed that the HBR of the cube is much smaller than the smallest combined position uncertainty (σ(sub min) > 5*HBR) at each time point of evaluation. This is necessary as the actual collision probability calculation is based on a first order, small variable expansion in the position components of the Gaussian probability density function. This leads to the collision probability rate being to second order in the combined HBR. The collision probability rate is in a concise, closed form containing exponential and error functions.

Frisbee, Joe↗

Comparison of fluence-rate determination techniques for the Advanced Test Reactor-Critical Facility

A technique using small, enriched uranium-aluminum alloy monitors to measure fission rates in fuel plate assembly reactors was developed at the Idaho National Laboratory Radiation Measurements Laboratory in support of Advanced Test Reactor Critical (ATR-C) Facility irradiations. Previous measurements were performed to determine the correlation between the beta-particle activity and the fission rate in the U-Al monitors following irradiation. The American Society for Testing and Materials (ASTM) has established a standard practice E704 for determining neutron fluence rate by radioactivation of depleted uranium by measuring the concentration of fission-products in irradiated uranium monitors. Rather than measuring the beta-particle decay from fission-products, the decay rate of fission-products is determined by gamma-ray spectroscopy. The feasibility of using a method adapted from the ASTM standard practice E704 was investigated for ATR-C irradiations and compared to the present method by analyzing a subset of 21 monitor wires using both methods. The resulting calculated fission rates agreed with an average standard deviation of 7.45%, within the average combined measurement error of 9.05%. Practical considerations such as expected fluence-rates, sample activity, and counting-time were compared between the two methods and the sources of error for each method were investigated. Quality assurance measurements utilizing the modified ASTM standard method are recommended for future test irradiation, but gross-beta-particle counting remains the most practical solution for ATR-C fluence-rate determination.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗