Search NASA⌕ Search

SEARCH · Search NASA

Results for “fitting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Measurement of neutrino oscillations using neutrino and antineutrino beams in the NOvA experiment

NOvA is a long-baseline accelerator neutrino oscillation experiment using the NuMIneutrino beam from Fermilab. Its main physics goals are to probe the 3-flavour oscillationparameters: neutrino mass hierarchy, CP-violating phase dcp and octant of .23 mixingangle by observing electron neutrino appearance and muon neutrino disappearance. Twofunctionally identical detectors are placed off-axis from the centre of the NuMI beam.The near detector at Fermilab is 100 m underground, and the far detector is locatedon the surface at Ash River, 810 km away from the beam source. The initial neutrinobeam spectra are measured using the near detector data and the oscillation parametersare extracted by fitting the observed data to the predicted neutrino spectrum in the fardetector.This thesis is centered around how to improve the sensitivity of |.m232| and .23 measurementsin the muon neutrino disappearance analysis. NOvA will take data for about12 years. The operation of the NOvA experiment for each year costs tens of millions ofdollars, thus it is valuable to maximise the sensitivity of the analysis. Three samples ofmuon neutrino events are studied in this thesis to improve the analysis sensitivities. First,higher energy muon neutrinos are investigated by extending the energy range in NOvA’scurrent standard analysis. Second, for the sample of events used in NOvA’s existing analysis,a new energy estimator which has been developed to improve the neutrino energy resolution is considered. Furthermore, in addition to binning the events as function ofenergy and hadronic energy fraction, three particle identifiers are introduced to separateneutrino events by signal purity to reduce the effects from backgrounds. Third, an additionallower purity sample of muon neutrino charged current (CC) events that look similarto neutral current events and have not been included in NOvA’s existing analyses havebeen studied.This thesis reanalyses NOvA’s data used in the 2020 analysis, corresponding to anexposure of 13.60×1020 protons on target (POT) in the neutrino beam mode recordedfrom February 6, 2014 to March 20, 2020, and 12.50×1020 protons on target in theantineutrino beam mode recorded between June 29, 2016 to February 26, 2019. Thisthesis has implemented a fit to Asimov fake data, generated where sin2 .23 = 0.59 and.m232 = 2.5 × 10-3 eV2. These sensitivity studies show that the uncertainty range of|.m232| at 1 s in the new analysis is reduced by 5.5% and the significance of maximaldisappearance rejection improves by 7.7%, compared to the standard analysis. This isequivalent to adding 11-16% more data. The best fit values of the oscillation parametersfrom fitting to the far detector (FD) data with the new analysis are found to besin2 .23 = 0.568+0.025-0.043 (sin2 .23 = 0.454+0.046-0.026) and .m232 = 2.399+0.055-0.070 × 10-3 eV2 (.m232= -2.427+0.055-0.067 × 10-3 eV2) for the normal (inverted) hierarchy. The difference in thebest fit for sin2 .23 (.m232) between the new analysis and NOvA’s 2020 analysis is around2% (1.4%). The uncertainty range at 1 s for .m232 decrease by 8% (4%) for the normalhierarchy (inverted hierarchy) compared to the standard analysis. The uncertainty rangefor sin2 .23 is close to the standard analysis. This thesis also implements the fit from combiningelectron neutrino appearance and muon neutrino disappearance. The combinedanalysis shows that the best fit values are very close to the standard analysis. However,the uncertainty range of .m232 at 1 s is reduced by 3.7% using the new analysis. The maximaldisappearance significance is not improved in the new analysis, but the new analysisslightly improves the rejection of the disfavoured octant.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Linear Optics From Closed Orbits (LOCO): An Introduction

The LOCO code is used to find and correct errors in the linear optics of storage rings. The original FORTRAN code was written to correct the optics of the NSLS X-Ray ring, and was applied soon thereafter to debug problems with the ALS optics. The ideas used in the code were developed from previous work at SLAC. Several years ago, LOCO was rewritten in MATLAB. As described in this newsletter, the MATLAB version includes a user-friendly interface, with many useful fitting and analysis options. LOCO has been used at many accelerators. Presently, a search for LOCO in the text of papers on the Joint Accelerator Conferences Website yields 107 papers. A comprehensive survey of applications will not be included here. Details of recent results at a few light sources are included in this newsletter. In the past, the quality of LOCO fitting results varied significantly, depending on the storage ring. In particular, the results were mixed for colliding beam facilities, where there tend to be fewer BPMs that in light sources. Fitting rings with less BPM data to constrain the fit optics parameters often led to unreasonably large fit quadrupole gradient variations. Recently, modifications have been made to the LOCO fitting algorithm which leads to much better results when the BPM data does not tightly constrain the fit parameters. The modifications are described in this newsletter, and an example of results with this new algorithm is included.

43 PARTICLE ACCELERATORS↗

A Policymaker's Guide to Feed-in Tariff Policy Design

Feed-in tariffs (FITs) are the most widely used renewable energy policy in the world for driving accelerating renewable energy (RE) deployment, accounting for a greater share of RE development than either tax incentives or renewable portfolio standard (RPS) policies. FITs have generated significant RE deployment, helping bring the countries that have implemented them successfully to the forefront of the global RE industry. In the European Union (EU), FIT policies have led to the deployment of more than 15,000 MW of solar photovoltaic (PV) power and more than 55,000 MW of wind power between 2000 and the end of 2009. In total, FITs are responsible for approximately 75% of global PV and 45% of global wind deployment. Countries such as Germany, in particular, have demonstrated that FITs can be used as a powerful policy tool to drive RE deployment and help meet combined energy security and emissions reductions objectives. This policymaker’s guide provides a detailed analysis of FIT policy design and implementation and identifies a set of best practices that have been effective at quickly stimulating the deployment of large amounts of RE generation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

INFORMATION ON THE MILKY WAY FROM THE TWO MICRON ALL SKY SURVEY WHOLE SKY STAR COUNT: THE STRUCTURE PARAMETERS

The K{sub s} -band differential star count of the Two Micron All Sky Survey (2MASS) is used to derive the global structure parameters of the smooth components of the Milky Way. To avoid complication introduced by other fine structures and significant extinction near and at the Galactic plane, we only consider Galactic latitude |b| > 30{sup 0} data. The star count data are fitted with a three-component model: double exponential thin disk and thick disk, and a power-law decay oblate halo. Using maximum likelihood, the best-fit local density of the thin disk is n{sub 0} = 0.030 {+-} 0.002 stars pc{sup -3}. The best-fit scale height and length of the thin disk are H{sub z1} = 360 {+-} 10 pc and H{sub r1} = 3.7 {+-} 1.0 kpc, and those of the thick disk are H{sub z2} = 1020 {+-} 30 pc and H{sub r2} = 5.0 {+-} 1.0 kpc, the local thick-to-thin disk density ratio is f{sub 2} = 7% {+-} 1%. The best-fit axis ratio, power-law index, and local density ratio of the oblate halo are {kappa} = 0.55 {+-} 0.15, p = 2.6 {+-} 0.6, and f{sub h} = 0.20% {+-} 0.10%, respectively. Moreover, we find some degeneracy among the key parameters (e.g., n{sub 0}, H{sub z1}, f{sub 2}, and H{sub z2}). Any pair of these parameters are anti-correlated to each other. The 2MASS data can be well fitted by several possible combinations of these parameters. This is probably the reason why there is a wide range of values for the structure parameters in literature similar to this study. Since only medium and high Galactic latitude data are analyzed, the fitting is insensitive to the scale lengths of the disks.

79 ASTRONOMY AND ASTROPHYSICS↗

A strongly selected mutation in the HIV-1 genome is independent of T cell responses and neutralizing antibodies

Mutations rapidly accumulate in the HIV-1 genome after infection. Some of those mutations are selected by host immune responses and often cause viral fitness losses. This study is to investigate whether strongly selected mutations that are not associated with immune responses result in fitness losses. Strongly selected mutations were identified by analyzing 5'-half HIV-1 genome (gag/pol) sequences from longitudinal samples of subject CH0131. The K43R mutation in the gag gene was first detected at day 91 post screening and was fixed in the viral population at day 273 while the synonymous N323tc mutation was first detected at day 177 and fixed at day 670. No conventional or cryptic T cell responses were detected against either mutation sites by ELISpot analysis. However, when fitness costs of both mutations were measured by introducing each mutation into their cognate transmitted/founder (T/F) viral genome, the K43R mutation caused a significant fitness loss while the N323tc mutation had little impact on viral fitness. In conclusion, the rapid fixation, the lack of detectable immune responses and the significant fitness cost of the K43R mutation suggests that it was strongly selected by host factors other than T cell responses and neutralizing antibodies.

59 BASIC BIOLOGICAL SCIENCES↗

Measurements of CP Asymmetries and Branching Fractions of Two-Body Charmless Decays of $B^0$ and $B^0_s$ Mesons

The thesis is organized as follows: Chapter 1 describes the theoretical framework of non-leptonic B$$0\atop{s}$$ → H +h' - decays, with a simple overview of the CP violation mechanism within the Standard Model and of the most used phenomenological approaches in the evaluation of strong interaction contributions. The chapter contains also a review of the theoretical expectations and the current experimental measurements along with a discussion about the importance of studying such decays. Chapter 2 contains a general description of the Tevatron collider and of the CDF II detector. Chapter 3 is devoted to the description of the data sample used for the measurement and the method used in extracting the signal from the background. Particular attention is dedicated to the on-line trigger selection, which is crucial to collect a sample enriched in B$$0\atop{s}$$ → h +h' - decays. Chapter 4 shows how the information from kinematics and particle identification was used to achieve a statistical discrimination amongst modes to extract individual measurements. The available resolutions in mass or in particle identification are separately insufficient for an event-by-event separation of B$$0\atop{s}$$ → h +h' - modes. The choice of observables and the technique used to combine them is an important and innovative aspect of the analysis described in this thesis. Chapter 5 is devoted to the accurate determination of the invariant mass lineshape. This is a crucial ingredient for resolving overlapping mass peaks. This chapter details all resolution effects with particular attention at the tails due to the emission of low-energy photons from charged kaons and pions in the final state (FSR). For the first time the effect of FSR has been accurately accounted for in a CDF analysis. Chapter 6 describes how kinematic and PID information, discussed in chap. 4 and chap. 5 were combined in a maximum Likelihood fit to statistically determine the composition of the B$$0\atop{s}$$ → h +h' - sample. This kinematics-PID combined fit has been developed and performed for the first time at CDF in the analysis presented in this thesis and this methodology was later inherited by several other analyses. Chapter 7 is devoted to the study of the isolation variable, which is a crucial handle to enhance the signal-to-background ratio in the off-line selection. It exploits the property that the b-hadrons tend to carry a larger fraction of the transverse momentum of the particles produced in the fragmentation, with respect to lighter hadrons. Since the simulators do not accurately reproduce the fragmentation processes, this chapter is devoted to the study of the control data sample of B$$0\atop{s}$$ → J/ΨX decays to probe the characteristics of this variable. Chapter 8 describes an innovative procedure used to optimize the selection to minimize the statistical uncertainty on the quantities one wishes to measure. The procedure is based on the fit of composition described in chap. 6. Chapter 9 reports the results of the fit of composition described in chap. 6 and the cross-checks performed to verify the goodness of the fit of composition. In order to translate the parameters returned from the fit into physics measurements the relative efficiency corrections between the various decay modes need to be applied. Chapter 10 is devoted to the description of these corrections. Chapter 11 describes the measurement of the detector-induced charge asymmetry between positively and negatively charged kaons and pions, due to their different probability of strong interaction in the tracker material using the real data. This allows to extract the acceptance correction factor for the CP asymmetries measurement without any external inputs from the simulation, and to perform a powerful check of whole analysis. Chapter 12 describes the main sources of systematic uncertainties and the method used to evaluate the significance of the results on rare modes. The final results of the measurements and their interpretation are discussed in chap. 13.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Feed-in Tariffs and Offshore Wind Power Development

This paper will briefly review the evolution and status of various feed‐in‐tariff programs (FITs) throughout Europe and North America. This paper will first outline feed-in tariffs in more detail and provide a summary of their design features, discuss how costs are calculated, address differences and adjustments to prices, highlight legal issues associated with FITs, and highlight some problems that FITs can face. The second part of the paper will give details of a number of FIT programs that have been established with a particular emphasis on those that relate to offshore wind. FITs have enjoyed widespread success in Europe, and by providing a reliable price and thereby leveling the playing field for renewable energy generators, FITs have fostered under‐developed renewable industries. Several European countries have experienced unprecedented growth in generation and industry after the adoption of feed-in tariffs, yet growth in the United States renewable energy sector has been markedly slow. An order by the Federal Energy Regulatory Commission (FERC) in July 2010 appeared to significantly hinder a state’s ability to develop flexible and fairly priced tariffs; however, a subsequent FERC clarification provided a platform for state tariff development based on practical price considerations. Continued federal leadership will be imperative to squarely address the needs of the renewable industry. By providing continued clarity and establishing state autonomy, FERC’s role can evolve to promote growth in this critical market segment. Absent direct guidance from Congress and federal regulatory agencies, this critical energy sector may languish as international markets capitalize on these flexible policies.

17 WIND ENERGY↗

Optimal Stopping Ages for Colorectal Cancer Screening

Importance Prior studies have shown that the benefits, harms, and costs of colorectal cancer (CRC) screening at older ages are associated with a patient’s sex, health, and screening history. However, these studies were hypothetical exercises and not directly informed by data on CRC risk. Objective To identify the optimal stopping ages for CRC screening by sex, comorbidity, and screening history from a cost-effectiveness perspective. Design, Setting, and Participants This economic evaluation first validated the MISCAN-Colon (Microsimulation Screening Analysis–Colon) model against community-based CRC incidence and mortality rates for 2 subcohorts of the PRECISE (Optimizing Colorectal Cancer Screening Precision and Outcomes in Community-Based Populations) cohort. Subsequently, different CRC screening scenarios were simulated in older individuals. Cohorts of US adults aged 76 to 90 years varied by sex and comorbidity status (none, low, moderate, or severe). Statistical and sensitivity analyses were performed from March 2023 to May 2024. Exposures CRC screening histories including fecal immunochemical test (FIT) or colonoscopy, such as a negative colonoscopy result from 10, 15, 20, 25, or 30 years before the index age; 1 to 5 negative FIT results within 5 years of the index age, with different patterns of recency; or a combination of negative colonoscopy and negative FIT results. Main Outcomes and Measures The main outcomes included estimated lifetime clinical outcomes, incremental costs, and quality-adjusted life-years gained (QALYG) associated with 1 additional FIT or colonoscopy. Optimal stopping age for screening, defined as the oldest age for which the incremental cost-effectiveness ratio was still below the willingness-to-pay threshold of $\$$100 000 per QALYG, was evaluated. Results The first of the 2 PRECISE subcohorts used in validating the simulation model included 25 974 adults (15 060 females [58.0%]; 54.7% aged 76 to 80 years) with a negative colonoscopy result 10 years before the index date. The second subcohort consisted of 118 269 adults (67 058 females [56.7%]; 90.5% aged 76 to 80 years) with a negative FIT result 1 year before the index date. Older age, male sex, higher comorbidity levels, and recent CRC screenings were associated with reduced incremental benefit and cost-effectiveness of additional screening. For the reference cohort of 76-year-old females without comorbidities and a negative colonoscopy result 10 years before the index age, 1 additional colonoscopy cost $\$$38 226 per QALYG. For cohorts with otherwise equivalent characteristics, associated costs increased to $\$$1 689 945 per QALYG for females at age 90 years without comorbidities and a negative colonoscopy results 10 years before the index age, $\$$51 604 per QALYG for males at age 76 years without comorbidities and a negative colonoscopy result 10 years before the index age, and $\$$108 480 per QALYG for females at age 76 years with severe comorbidities and a negative colonoscopy result 10 years before the index age and decreased to $\$$16 870 per QALYG for females without comorbidities and a negative colonoscopy result 30 years before the index age. The optimal stopping ages across different cohorts ranged from younger than 76 to 86 years for colonoscopy and younger than 76 to 88 years for FIT. Conclusions and Relevance In this economic evaluation, age, sex, screening history, comorbidity, and future screening modality were associated with the clinical outcomes, cost-effectiveness, and optimal stopping age for CRC screening. These results can inform guideline development and patient-directed informed decision-making.

Harlass, Matthias [Erasmus Erasmus University Medi↗

Seven years of aerosol scattering hygroscopic growth measurements from SGP: Factors influencing water uptake: Aerosol Scattering Hygroscopic Growth

Long-term measurements of changes in the aerosol scattering coefficient hygroscopic growth at the U.S. Department of Energy Southern Great Plains site provide information on the seasonal as well as size and chemical dependence of aerosol hygroscopic growth. Annual average sub 10 um fRH values (the ratio of aerosol scattering at 85%/40% RH) were 1.75 and 1.87 for the gamma and kappa fit algorithms, respectively. The study found higher growth rates in the winter and spring seasons that correlated with high aerosol nitrate mass fraction. FRH, exhibited strong, but differing correlations with the scattering Ångström exponent and backscatter fraction, two optical size-dependent parameters. The aerosol organic fraction had a strong influence, with fRH decreasing with increases in the organic mass fraction and absorption Ångström exponent and increasing with the aerosol single scatter albedo. Uncertainty analysis if the fit algorithms revealed high uncertainty at low scattering coefficients and slight increases in uncertainty at high RH and fit parameters values.

Jefferson, A.↗

Interactions of πK, ππK and KKπ systems at maximal isospin from lattice QCD

We study the interactions of systems of two and three nondegenerate mesons composed of pions and kaons at maximal isospin using lattice QCD, specifically $π^+K^+, π^+π^+K^+$ and $K^+K^+π^+$. Utilizing the stochastic LapH method, we determine the spectrum of these systems on two CLS $N_f$ = 2 + 1 ensembles with pion masses of 200 MeV and 340 MeV, and include many levels in different momentum frames. We constrain the K matrices describing two- and three-particle interactions by fitting the spectrum to the results predicted by the finite-volume formalism, including up to p waves. This requires also results for the $π^+π^+$ and $K^+K^+$ spectrum, which have been obtained previously on the same configurations. We explore different fitting strategies, comparing fits to energy shifts with fits to energies boosted to the rest frame, and also comparing simultaneous global fits to all relevant two- and three-particle channels to those where we first fit twoparticle channels and then add in the three-particle information. We provide the first determination of the three-particle K matrix in $π^+π^+K^+$ and $K^+K^+π^+$ systems, finding statistically significant nonzero results in most cases. We include s and $\textit{p}$ waves in the K matrix for $π^+K^+$ scattering, finding evidence for an attractive p-wave scattering length. We compare our results to Chiral Perturbation Theory, including an investigation of the impact of discretization errors, for which we provide the leading order predictions obtained using Wilson Chiral Perturbation Theory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiation Pneumonitis After Hypofractionated Radiotherapy: Evaluation of the LQ(L) Model and Different Dose Parameters

Purpose: To evaluate the linear quadratic (LQ) model for hypofractionated radiotherapy within the context of predicting radiation pneumonitis (RP) and to investigate the effect if a linear (L) model in the high region (LQL model) is used. Methods and Materials: The radiation doses used for 128 patients treated with hypofractionated radiotherapy were converted to the equivalent doses given in fractions of 2 Gy for a range of {alpha}/{beta} ratios (1 Gy to infinity) according to the LQ(L) model. For the LQL model, different cut-off values between the LQ model and the linear component were used. The Lyman model parameters were fitted to the events of RP grade 2 or higher to derive the normal tissue complication probability (NTCP). The lung dose was calculated as the mean lung dose and the percentage of lung volume (V) receiving doses higher than a threshold dose of xGy (V{sub x}). Results: The best NTCP fit was found if the mean lung dose, or V{sub x}, was calculated with an {alpha}/{beta} ratio of 3 Gy. The NTCP fit of other {alpha}/{beta} ratios and the LQL model were worse but within the 95% confidence interval of the NTCP fit of the LQ model with an {alpha}/{beta} ratio of 3 Gy. The V{sub 50} NTCP fit was better than the NTCP fit of lower threshold doses. Conclusions: For high fraction doses, the LQ model with an {alpha}/{beta} ratio of 3 Gy was the best method for converting the physical lung dose to predict RP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-resolution rovibrational study of the Coriolis-coupled v 12 and v 15 modes of [1.1.1]propellane

Infrared spectra of the small strained cage molecule [1.1.1]propellane have been obtained at high resolution (0.0015 cm -1 ) and the J and K, l rovibrational structure has been resolved for the first time. We recently used combination-differences to obtain ground state parameters for propellane; over 4,100 differences from five fundamental and four combination bands were used in this process. The combination-difference approach eliminated errors due to localized perturbations in the upper state levels of the transitions and gave well-determined ground state parameters. In the current work, these ground state parameters were used in a determination of the upper state parameters for the v 12 (e') perpendicular and v 15 (a 2 ") parallel bands. Over 4000 infrared transitions were fitted for each band, with J, K values ranging up to 71, 51 and 92, 90 respectively. While the transition frequencies for both bands can be fit nicely using separate analyses for each band, the strong intensity perturbations observed in the weaker v 12 band indicated that Coriolis coupling between the two modes was significant and should be included. Due to correlations with other parameters, the Coriolis coupling parameter ζ y 15,12a for the v 15 and v 12 interaction is poorly determined by a transition frequency fit alone. However, by combining the frequency fit with a fit of experimental intensities, a value of -0.42 was obtained, quite close to that predicted from the ab initio calculation (-0.44). This intensity fit also yielded a (∂μ z /∂Q 15 )/(∂μ x /∂Q 12a ) dipole derivative ratio of 36.5, in reasonable agreement with a value of 29.2 predicted by Gaussian ab initio density functional calculations using a cc-pVTZ basis. This ratio is unusually high due to large charge movement as the novel central Caxial-Caxial bond is displaced along the symmetry axis of the molecule for the v 15 mode.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Erratum to. Energy calibration of gamma spectra in plastic scintillators using Compton kinematics [Nucl. Instr. and Meth. A 594 (2008) 232–243]

In recent work at our laboratory, we were re-examining our data and found an inconsistency between the values listed for 137 Cs in Table 2 (Siciliano et al. 2008) and results plotted for that source in Figures 11 and 12. In the course of fitting the parabolic function (Equation 4) to the Compton maxima, two ranges of channels were used when determining the parameters for 137 Cs. The parabolic fit curve shown in Figure 11 resulted from fitting channels 50 to 70. The parameters for that fit are: are: A = 0.972(12), B = 1.42(24) x 10 -3 , and C NO = 60.2(5). The parameters for 137 Cs listed in Table 2 (and also used to determine the calibration relations in Figure 12—the main result of this paper) came from fitting the 137 Cs data in channels 40 to 80. Although the curves plotted from these two different sets of parameters would be visually distinguishable in Figure 11, when incorporated with the other isotope values shown in Figure 12 to obtain the linear energy-channel fit, the 50-70 channel parameter set plus the correction from the Compton maximum to the Compton edge gives a negligible change in the slope [6.470(41) as opposed to the reported 6.454(15) keV/channel] and a small change in the intercept [41(8) as opposed to 47(3) keV] for the dashed line. The conclusions of the article therefore do not change as a result of this inconsistency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A method for simultaneous linear optics and coupling correction for storage rings with turn-by-turn beam position monitor data

We propose a method to simultaneously correct linear optics errors and linear coupling for storage rings using turn-by-turn (TbT) beam position monitor (BPM) data. The independent component analysis (ICA) method is used to isolate the betatron normal modes from the measured TbT BPM data. The betatron amplitudes and phase advances of the projections of the normal modes on the horizontal and vertical planes are then extracted, which, combined with dispersion measurement, are used to fit the lattice model. The fitting results are used for lattice correction. The method has been successfully demonstrated on the NSLS-II storage ring.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A high-performance track fitter for use in ultra-fast electronics

This article describes a new charged-particle track fitting algorithm designed for use in high-speed electronics applications such as hardware-based triggers in high-energy physics experiments. Following a novel technique designed for fast electronics, the positions of the hits on the detector are transformed before being passed to a linearized track parameter fit. This transformation results in fitted track parameters with a very linear dependence on the hit positions. The approach is demonstrated in a representative detector geometry based on the CMS detector at the Large Hadron Collider. The fit is implemented in FPGA chips and optimized for track fitting throughput and obtains excellent track parameter performance. Furthermore, such an algorithm is potentially useful in any high-speed track-fitting application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation and uncertainty quantification of detector response functions for a $1"×2"$ NaI collimated detector intended for inverse radioisotope source mapping applications

Detector response functions (DRFs) are often used for inverse analysis. We compute the DRF of a sodium iodide (NaI) nuclear material holdup field detector using the code named g03 developed by the Center for Engineering Applications of Radioisotopes (CEAR) at NC State University. Three measurement campaigns were performed in order to validate the DRF’s constructed by g03: on-axis detection of calibration sources, off-axis measurements of a highly enriched uranium (HEU) disk, and on-axis measurements of the HEU disk with steel plates inserted between the source and the detector to provide attenuation. Furthermore, this work quantifies the uncertainty of the Monte Carlo simulations used in and with g03, as well as the uncertainties associated with each semi-empirical model employed in the full DRF representation. Overall, for the calibration source measurements, the response computed by the DRF for the prediction of the full-energy peak region of responses was good, i.e. within two standard deviations of the experimental response. In contrast, the DRF tended to overestimate the Compton continuum by about 45–65% due to inadequate tuning of the electron range multiplier fit variable that empirically represents physics associated with electron transport that is not modeled explicitly in g03. For the HEU disk measurements, computed DRF responses tended to significantly underestimate (more than 20%) the secondary full-energy peaks (any peak of lower energy than the highest-energy peak computed) due to scattering in the detector collimator and aluminum can, which is not included in the g03 model. We ran a sufficiently large number of histories to ensure for all of the Monte Carlo simulations that the statistical uncertainties were lower than their experimental counterpart’s Poisson uncertainties. The uncertainties associated with least-squares fits to the experimental data tended to have parameter relative standard deviations lower than the peak channel relative standard deviation in most cases and good reduced chi-square values. The highest sources of uncertainty were identified as the energy calibration polynomial factor (due to limited source availability and NaI resolution) and the Ba-133 peak fit (only a very weak source was available), which were 20% and 10%, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimating the color lifetime of energetic quarks

Using a simple geometric framework with a realistic nuclear density distribution, we fit published HERMES data to determine fundamental properties of hadronization using the nuclear medium as a spatial analyzer. Our approach uses a fit to the transverse momentum broadening observable and the hadronic multiplicity ratio; the simultaneous fit to two different observables strongly constrains the outcome. Using the known sizes of the target nuclei, we extract the color lifetime, finding a z h -dependent range of values from 2 to 8 fm/c for these data. We also extract estimates for the qˆ transport coefficient characterizing the strength of the interaction between the quark and the cold nuclear medium, finding an average value of 0.035±0.011 GeV 2 /fm. With a three-parameter model we obtain satisfactory fits to the data with a goodness-of-fit parameter χ 2 /dof of 1.1 or less. In a secondary fit of the results from that model we independently find a value for the Lund String Model string tension of 1.00±0.05 GeV/fm. We evaluated the sensitivity for extracting quark energy loss and effective in-medium hadronic cross sections using four-parameter variants of the model, finding large uncertainties in both cases. Our results suggest that hadronic interaction of forming hadrons in the nuclear medium is the primary dynamical cause of meson attenuation in the HERMES data, with quark energy loss playing a more minor role.

Electron-ion collider↗

Interpreting the Operando XANES of Surface-Supported Subnanometer Clusters: When Fluxionality, Oxidation State, and Size Effect Fight.

X-ray absorption near edge structure (XANES) spectroscopy is widely used for operando catalyst characterization. We show that, for highly fluxional supported nanoclusters, the customary extraction of the oxidation state of the metal from the XANES data by fitting to the bulk standards is highly questionable. The XANES signatures as well as the apparent oxidation state for such clusters arise from a complex combination of many factors, and not only from the chemical composition in reaction conditions (e.g., oxygen content in oxidizing atmosphere). The thermally accessible isomerization and population of several structurally distinct cluster forms, cluster-support interaction, and intrinsic size effects all impact the metal oxidation state and XANES signal. We demonstrate this on copper oxide clusters with different compositions, Cu4Ox(x = 2-5) and Cu5Oy (y = 3, 5), deposited on amorphous alumina and ultrananocrystalline diamond, for which we computed the XANES spectra and compare the results to the experiment. We show in addition that fitting the experimental spectrum to calculated spectra of supported clusters can, in contrast, provide good agreement and insight into the spectrum-composition-structure relation. Experimental XANES interpreted using the proposed fitting scheme shows the partial reduction of Cu oxide clusters at rising temperatures, and pinpoints the specific stoichiometries that dominate in the ensemble of cluster states as the temperature changes.

Zandkarimi, Borna↗