Search NASA⌕ Search

SEARCH · Search NASA

Results for “flow test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Orifice Mass Flow Calculation in NASA's W-8 Single Stage Axial Compressor Facility

Updates to the orifice mass flow calculation for the W-8 Single Stage Axial Compressor Facility at NASA Glenn Research Center are provided to include the effect of humidity and incorporate ISO 5167. A methodology for including the effect of humidity into the inlet orifice mass flow calculation is provided. Orifice mass flow calculations provided by ASME PTC-19.5-2004, ASME MFC-3M-2004, ASME Fluid Meters, and ISO 5167 are compared for W-8's atmospheric inlet orifice plate. Differences in expansion factor and discharge coefficient given by these standards give a variation of about +/- 75% mass flow except for a few cases. A comparison of the calculations with an inlet static pressure mass flow correlation and a fan exit mass flow integration using test data from a 2017 turbofan rotor test in W-8 show good agreement between the inlet static pressure mass flow correlation, ISO 5167, and ASME Fluid Meters. While W-8's atmospheric inlet orifice plate violates the pipe diameter limit defined by each of the standards, the ISO 5167 is chosen to be the primary orifice mass flow calculation to use in the W-8 facility.

Aerodynamics↗

Effects of Confinement on Flame Spread in Microgravity

Solid fuel combustion experiments aboard the ISS examine the effects of confinement on a concurrent, purely-forced-flow flame spread in microgravity environment. The results for a thin, cotton-fiberglass-blended textile fabric fuel are presented. Flat baffles of differing materials are used to alter the radiative boundary conditions with transparent polycarbonate, black anodized aluminum (reflectance ~ 0), and highly polished aluminum (reflectance ~ 1). The baffles are parallel to the fuel sheet and placed symmetrically on each side. The inter-baffle distance is varied to change the boundary conditions for the flow. In all tests, samples are ignited at the upstream leading edge and allowed to burn to completion. Results show that the flame reaches a steady length and spread rate at low flow speeds (< 15 cm/s) for all tested inter-baffle distances. As the distance decreases, the flame length and spread rate first increase then decrease showing an optimal inter-baffle distance. For all baffle types, the flame either fails to ignite or extinguishes before reaching the end of the sample when the inter-baffle distance is too small (~ 1 cm). This is attributed to the reduction of oxygen supply to the flame zone and heat loss to the baffles. The results also show at the same inter-baffle distance, flame length and spread rate are highest for polished aluminum baffles, and lowest for transparent polycarbonate baffles. The differences are most prominent at intermediate tested baffle distances. While the radiative heat feedback from the baffles is expected to increase when the baffle distance decreases, the combustion is limited by the reduced oxygen supply. Near this limit, flame lengths and spread rates are similar for all baffle types.

Microgravity↗

Verification of Anisotropic Mesh Adaptation for Complex Aerospace Applications

The stabilized finite element solver, FUN3D-SFE, along with the grid mechanics package refine are verified for aerospace applications of laminar and turbulent flow simulations. The current verification exercise represents an extension of previous research using FUN3D-SFEwith adjoint-based mesh adaptation to generate highly anisotropic adapted meshes for inviscid problems. Adaptations are performed using a solution-based approach that controls the Lpnorm of Mach number interpolation error and an adjoint-based approach that controls the error in some output functional. Adaptive results are shown for laminar subsonic flow over a delta wing, laminar subsonic flow over ONERA M6 wing, inviscid supersonic flow over a sonic boom test case, and a turbulent flow over a high lift configuration (JAXA Standard Model). Mesh convergence results are also compared with results from FUN3D-FV (Finite Volume) whenever available. For all test cases considered, FUN3D-SFE gives significantly better accurate results than FUN3D-FV on coarse meshes.

Aravind Balan↗

Mass spectrometer measurements of test gas composition in a shock tunnel

Shock tunnels afford a means of generating hypersonic flow at high stagnation enthalpies, but they have the disadvantage that thermochemical effects make the composition of the test flow different to that of ambient air. The composition can be predicted by numerical calculations of the nozzle flow expansion, using simplified thermochemical models and, in the absence of experimental measurements, it has been necessary to accept the results given by these calculations. This note reports measurements of test gas composition, at stagnation enthalpies up to 12.5 MJ.kg(exp -1), taken with a time-of-flight mass spectrometer. Limited results have been obtained in previous measurements. These were taken at higher stagnation enthalpies, and used a quadruple mass spectrometer. The time-of-flight method was preferred here because it enabled a number of complete mass spectra to be obtained in each test, and because it gives good mass resolution over the range of interest with air (up to 50 a.m.a.).

Skinner, K. A.↗

Effect of nacelles on aerodynamic characteristics of an executive-jet model with simulated, partial-chord, laminar-flow-control wing glove

Tests were conducted in the Langley High-Speed 7- by 10-Foot Tunnel using a 1/10-scale model of an executive jet to examine the effects of the nacelles on the wing pressures and model longitudinal aerodynamic characteristics. For the present investigation, each wing panel was modified with a simulated, partial-chord, laminar-flow-control glove. Horizontal-tail effects were also briefly examined. The tests covered a range of Mach numbers from 0.40 to 0.82 and lift coefficients from 0.20 to 0.55. Oil-flow photographs of the wing at selected conditions are included.

Campbell, R. L.↗

Selection of LAW Glasses for FY 2016 SPFT Testing

The primary objective of this work is to provide recommendations for glasses to be used for Single Pass Flow Through (SPFT) testing in FY 2016. Since LAW glass formulation development is ongoing, particularly with respect to enhanced formulations with increased waste loading as compared to the present WTP baseline, it is anticipated that this report will be revised on an annual basis in order to provide appropriate recommendation for testing in each fiscal year.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Field Experiments and Model Validation: The EGS Collab Project

Implementing enhanced geothermal systems (EGS) will require improvements in understanding stimulation of crystalline rock to create appropriate flow pathways, and the ability to effectively simulate both the stimulation and the flow and transport processes in the resulting fracture network. The US Department of Energy (DOE) is addressing these and other challenges at multiple scales. The EGS Collab project, addressed here, is performing tests and modeling at the 10 m scale. The FORGE project is performing tests at the full reservoir scale. The EGS Collab team created an underground testbed at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, at a depth of approximately 1.5 km to examine hydraulic fracturing (Experiment 1). We are currently building a second testbed at SURF at a depth of about 1.25 km aimed at investigating shear stimulation (Experiment 2). In Experiment 1, we drilled eight boreholes in a well-characterized phyllite and installed geophysical sensors in six of them to create a well-instrumented testbed to allow careful monitoring of stimulation events and flow tests. Numerical simulation was used to answer key experimental design questions, to forecast fracture propagation trajectories and extents, and to analyze and evaluate results both in near-real-time and in detailed process studies. Stimulations performed in this testbed allowed quantification of processes occurring during stimulation and the examination of dynamic flow occurrences. Long-term ambient temperature and chilled water flow tests were performed in addition to many tracer tests to examine system behavior. Our second testbed, targeted at shear stimulation, is currently being built at the SURF Facility at a depth of about 1.25 km in amphibolite under a different set of stress and fracture conditions than Experiment 1.

artificial intelligence↗

Development and Validation of Methodology to Model Flow in Ventilation Systems Commonly Found in Nuclear Facilities - Phase II

In this report we present the results of the Phase II analysis and testing of the flow patterns encountered in the Alpha Gamma Hot Cell Facility (AGHCF), as well as the results from an opportunity to expand upon field test work from Phase I by the use of a Class IIIb laser. The addition to the Phase I work is covered before proceeding to the results of the Phase II work, followed by a summary of findings.

42 ENGINEERING↗

Flow Visualization of Liquid Hydrogen Line Chilldown Tests

We present experimental measurements of wall and fluid temperature during chill-down tests of a warm cryogenic line with liquid hydrogen. Synchronized video and fluid temperature measurements are used to interpret stream temperature profiles versus time. When cold liquid hydrogen starts to flow into the warm line, a sequence of flow regimes, spanning from all-vapor at the outset to bubbly with continuum liquid at the end can be observed at a location far downstream of the cold inlet. In this paper we propose interpretations to the observed flow regimes and fluid temperature histories for two chilldown methods, viz. trickle (i.e. continuous) flow and pulse flow. Calculations of heat flux from the wall to the fluid versus wall temperature indicate the presence of the transition/nucleate boiling regimes only. The present tests, run at typical Reynolds numbers of approx O(10 (exp 5)), are in sharp contrast to similar tests conducted at lower Reynolds numbers where a well-defined film boiling region is observed.

Line chill down↗

TPSAS-NF1676L-32577-DND

The ground testing of hypersonic vehicles requires the replication of the flow conditions at high speed and altitude. To produce these flow conditions, stored compressed air is expanded through a convergent-divergent nozzle to produce the required pressures and speed. However, the expansion process also cools the air, and so to match the flight temperatures, some form of heating needs to be employed. Vitiated heating is a common method, where the air is heated by burning fuel in the low speed side of the nozzle, and then oxygen is added to bring the level of O2 up to match that of standard air. The resulting flow no longer has the same composition as standard air, (except for the oxygen level), but rather contains combustion products, often referred to as vitiates as part of the mixture. The presence of these vitiates in the flow effects the wind tunnel test conditions. For example, the specific heat and molecular density are changed, the kinetics of combustion are altered and the flow features in the test article are altered. In this talk, the effects of the vitiates on the testing conditions and on the performance of test articles is described. Specific examples include the effects of molecular density on the flow, how combustion processes are altered by the presence of vitiates and how condensation of vitiates can alter the test conditions. In addition, the effect of the less common vitiates produced by arc-heated tunnels are mentioned, such as NO, non-thermal equilibrium and the presence of copper solids in the flow. Finally some thoughts on how large an effect these vitiates have on the test results are presented.

Andrew T Norris↗

Hardening of A6111-T4 Aluminum Alloy at Large Strains and Its Effect on Sheet Forming Operations

In a number of sheet metal stamping and joining processes, the material undergoes large plastic deformation exceeding the range of plastic strain achievable in a standard tensile test prior to material plastic instability. In order to extend the range of effective strains, the multistep rolling process was employed which enabled prestraining of aluminum sheet above 2.0 of true strain. Tensile testing of rolled samples was used to identify the flow stress corresponding to the level of prestrain: By varying the prestrain level, several data points were obtained for the studied flow curve. The numerical simulation using Abaqus software for the cold rolling process of aluminum strips confirmed that majority of the strip is deformed in plane strain compression condition. Performed simulation of the LDH test determined that earlier fracture might occur if the curve obtained via rolling–tensile testing approach is used versus traditional power law approximation and Voce law approximation. The results of simulation for the multistep drawing of a cylindrical cup revealed possible wrinkling in the die entry area during redrawing stage of the process if the rolling–tensile testing flow curve is employed.

36 MATERIALS SCIENCE↗

A subgrid-scale model based on the second-order velocity structure function

A series of tests were performed to help extend the use of a subgrid-scale model to compressible and wall-bounded flows. A priori tests were done in the case of the incompressible turbulent channel flow. They showed that a 1-D formulation of the structure-function model is more appropriate, leading to a satisfactory behavior of the model at the walls without requiring any damping function. This model is consistent with the original formulation of Metais & Lesieur (1990). In large-eddy simulations of compressible isotropic turbulence, both models performed well up to an initial rms Mach number of 0.6.

Comte, P.↗

Accelerometers in flow fields: a structural analysis of the chopped dummy in-pile tube

Four tests characterizing the structural response of the Chopped-Dummy In-Pile tube (CDIPT) experiment design were measured in the Hydro-Mechanical Fuel Test Facility (HMFTF). Four different test configurations were tried. These configurations tested the pressure drop and flow impact of various plate configurations and flow control orifices to be used later at different reactor power levels. Accelerometers were placed on the test vehicle and flow simulation housing. A total of five accelerometers were used with one on the top and bottom of the flow simulator and vehicle, and one on the outside of the flow simulator. Data were collected at a series of flow rates for 5 seconds each at an acquisition rate of 2 kHz for a Nyquist frequency of 1 kHz. The data were then analyzed using a Fast Fourier Transform (FFT) algorithm. The results show very coherent vibrations of the CDIPT experiment on the order of 50 Hz in frequency and 0.01 m/s{sup 2} in magnitude. The coherent vibrations, although small in magnitude pose a potential design problem if the frequencies coincide with the natural frequency of the fueled plates or test vehicle. The accelerometer data was integrated and combined to create a 3D trace of the experiment during the test. The merits of this data as well as further anomalies and artifacts are also discussed as well as their relation to the instrumentation and experiment design. (authors)

42 ENGINEERING↗

Overview of Experimental Investigations for Ares I Launch Vehicle Development

Another concern for the vehicle during its design trajectory was the separation of the first stage solid rocket booster from the upper stage component after it had depleted its solid fuel propellant. There has been some concern about the interstage of the first stage from clearing the nozzle of the J2-X engine. A detailed separation aerodynamic wind tunnel investigation was conducted in the AEDC VKF Tunnel A to help to investigate the interaction aerodynamic effects5. A comparison of the separation plane details between the Ares I architecture and the Ares I-X demonstration flight architecture is shown in figure 12. The Ares I design requires a more complex separation sequence and requires better control in order to avoid contact with the nozzle of the upper stage engine. The interstage, which houses the J2-X engine for the Ares I vehicle, must be able to separate cleanly to avoid contact of the J2-X engine. There is only about approximately 18 inches of buffer inside the interstage on each size of the nozzle so this is a challenging controlled separation event. This complex experimental investigation required two separate Ares I models (upper stage and first stage with interstage attached) with independent strain gauge balances installed in each model. It also required the Captive Trajectory System (CTS) that was needed to precisely locate the components in space relative to each other to fill out the planned test matrix. The model setup in the AEDC VKF Tunnel A is shown in figure 13. The CTS remotely positioned the first stage at the required x, y, and z positions and was able to provide interactions within 0.2" of the upper stage. A sample of the axial force on the first stage booster is shown in figure 14. These results, as a function of separation distance between the two stages, are compared to pre-test CFD results. Since this is a very challenging, highly unsteady flow field for CFD to correctly model, the experimental results have been utilized by GN&C discipline to more accurately represent the interaction aerodynamics. In addition to the integrated forces and moments obtained from the test, flow visualization data was obtained from this test in the form of Schlieren photographs, as shown in figure 15, which show the shock structure and interaction effects after the two stages separate during flight. This separation test was crucial in the successful flight test of the Ares I-X vehicle and provided the GN&C discipline with the unpowered proximity aerodynamic effect for a separation of the Ares I vehicle.

Tomek, William G.↗

Mineral assemblage transformation of a metakaolin-based waste form after geopolymer encapsulation

Current plans for nuclear waste vitrification at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) lack the capacity to treat all of the low activity waste (LAW) that is not encapsulated in the vitrified product. Fluidized Bed Steam Reforming (FBSR) is one of the supplemental technologies under consideration to fill this gap. The FBSR process results in a granular product mainly composed of feldspathoid mineral phases that encapsulate the LAW and other contaminants of concern (COCs). In order to better understand the characteristics of the FBSR product, characterization testing has been performed on the granular product as well as the granular product encapsulated in a monolithic geopolymer binder. The non-radioactive simulated tank waste samples created for use in this study are the result of a 2008 Department of Energy sponsored Engineering Scale Technology Demonstration (ESTD) in 2008. These samples were created from waste simulant that was chemically shimmed to resemble actual tank waste, and rhenium has been used as a substitute for technetium. Another set of samples was created by the Savannah River Site Bench-Scale Reformer (BSR) using a chemical shim of Savannah River Site Tank 50 waste in order to simulate a blend of 68 Hanford tank wastes. This paper presents results from coal and moisture removal tests along with XRD, SEM, and BET analyses showing that the major mineral components are predominantly sodium aluminosilicate minerals and that the mineral product is highly porous. Results also show that the materials pass the short-term leach tests: the Toxicity Characteristic Leaching Procedure (TCLP) and Product Consistency Test (PCT).

Feldspathoid Minerals↗

NASA Ames's electric arc-driven shock tube facility and research on nonequilibrium phenomena in low density hypersonic flows

Basic requirements for a ground test facility simulating low density hypersonic flows are discussed. Such facilities should be able to produce shock velocities in the range of 10-17 km/sec in an initial pressure of 0.010 to 0.050 Torr. The facility should be equipped with diagnostics systems to be able to measure the emitted radiation, characteristic temperatures and populations in various energy levels. In the light of these requirements, NASA Ames's electric arc-driven low density shock tube facility is described and available experimental diagnostics systems and computational tools are discussed.

Sharma, Surendra P.↗