Search NASA⌕ Search

SEARCH · Search NASA

Results for “image coding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

MO-AB-206-01: PET Physics

This education session will cover the physics and operation principles of gamma cameras and PET scanners. The first talk will focus on PET imaging. An overview of the principles of PET imaging will be provided, including positron decay physics, and the transition from 2D to 3D imaging. More recent advances in hardware and software will be discussed, such as time-of-flight imaging, and improvements in reconstruction algorithms that provide for options such as depth-of-interaction corrections. Quantitative applications of PET will be discussed, as well as the requirements for doing accurate quantitation. Relevant performance tests will also be described. Learning Objectives: Be able to describe basic physics principles of PET and operation of PET scanners. Learn about recent advances in PET scanner hardware technology. Be able to describe advances in reconstruction techniques and improvements Be able to list relevant performance tests. The second talk will focus on gamma cameras. The Nuclear Medicine subcommittee has charged a task group (TG177) to develop a report on the current state of physics testing of gamma cameras, SPECT, and SPECT/CT systems. The report makes recommendations for performance tests to be done for routine quality assurance, annual physics testing, and acceptance tests, and identifies those needed satisfy the ACR accreditation program and The Joint Commission imaging standards. The report is also intended to be used as a manual with detailed instructions on how to perform tests under widely varying conditions. Learning Objectives: At the end of the presentation members of the audience will: Be familiar with the tests recommended for routine quality assurance, annual physics testing, and acceptance tests of gamma cameras for planar imaging. Be familiar with the tests recommended for routine quality assurance, annual physics testing, and acceptance tests of SPECT systems. Be familiar with the tests of a SPECT/CT system that include the CT images for SPECT reconstructions. Become knowledgeable of items to be included in annual acceptance testing reports including CT dosimetry and PACS monitor measurements. T. Turkington, GE Healthcare.

61 RADIATION PROTECTION AND DOSIMETRY↗

Investigation of the OECD/NEA PWR MOX/UO{sub 2} core transient benchmark using a coupled whole core pin-by-pin route in WIMS

This paper investigates the new CAMELOT coupling route developed in WIMS, which uses prepared tabulated cross-sections combined with the flux solver MERLIN module and the integrated sub-channel thermal hydraulics solver ARTHUR module to solve for the coupled core state. This coupling route is applied to the OECD/NEA pressurized water reactor (PWR) core transient benchmark exercise, involving 3-D neutronics and thermal-hydraulics analysis of a full-sized PWR core featuring MOX fuel at various core states, as well as simulating a control rod ejection transient. Analysis of the results for each part of the benchmark demonstrate that the high-resolution pin-by-pin analysis used in WIMS closely matches the other participants in the benchmark, with differences of between 20-200 pcm for k-effective, 1-2.5% RMS difference for assembly-averaged powers, 2-8% difference in rod worth calculations, < 200 ppm for calculations of critical boron concentration, zero difference in delayed neutron fraction calculation and a very close match for power response to the rod ejection transient. This is the first application of the WIMS-CAMELOT approach for the transient analysis of a full-sized reactor and as such further improvements such as reducing computational cost through parallelization, optimisation and memory reduction, are currently in active development. This paper demonstrates the accuracy and flexibility of the CAMELOT coupling route, providing a straightforward and consistent user image that can be easily used for a variety of modelling problems involving coupled neutronics and thermal-hydraulics. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Resolving the fast ion distribution from imaging neutral particle analyzer measurements

A recently developed imaging neutral particle analyzer (INPA) on the DIII-D tokamak (Du 2018 Nucl. Fusion 58 082006) enables fast ion velocity-space tomography of high fidelity at the interrogated phase space. To accomplish this, the spatial and energy depending fast ( E < 80 keV) neutral flux towards the INPA stripping foils is calculated with FIDASIM and a newly developed code INPASIM simulates the INPA instrumental response to this neutral flux. Included in INPASIM is the neutral-foil interaction, the Larmor orbit tracing between the foil and the phosphor, the phosphor response to the incident ion flux as well as camera focusing. Benefiting from heavy, localized velocity-space weights and excellent signal to noise, computed tomography using the Ridge regression method is able to successfully reconstruct fine-scale velocity-space structures produced by multiple neutral beams separated by as small as ~3 keV in tests. Applying the inversion method to a sawtooth crash event reveals a significant profile flattening of confined passing particles across q = 1 flux surface, as well as a redistribution of fast ions into the trapped orbits at the plasma edge close to the last closed flux surface.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigation of Materials for Radio Frequency Antenna Plasma Facing Components

Here, the interaction of radio frequency (RF) sheaths with fusion reactor relevant materials (e.g., tungsten and titanium diboride) is being studied on the RF Plasma Interaction Experiment (RF PIE). The RF PIE consists of an electron cyclotron resonance (ECR) plasma source (2.45 GHz, 5 kW) with a biased and heated RF electrode that is used to simulate antenna surfaces in contact with the edge plasma. Helium plasmas (density of ~1e18/m 3 , electron temperature of 4–5 eV) are being used to explore sheath formation on material surfaces with biases up to 500 V. The erosion of a tungsten surface is being studied spectroscopically using a mirror-linked 1 m Czerny-Turner UV imaging spectrometer with a spectral resolution of 0.012 nm for measuring plasma emission in and near the sheath. Tungsten line emission intensity is higher for RF versus dc biasing for similar plasma conditions and average ion energy. RF biasing causes a broadening of the ion energy distribution function (IEDF) due to the RF sheath, as determined from the hPIC2 code, and results in enhanced sputtering. Calculations of the expected sputtering yield for dc and RF biasing are consistent with experimental observations of changes in the 400.9 nm tungsten line emission intensity as a function of ion energy.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast 2D Bicephalous Convolutional Autoencoder for Compressing 3D Time Projection Chamber Data

High-energy large-scale particle colliders produce data at high speed in the order of 1 terabytes per second in nuclear physics and petabytes per second in high energy physics. Developing real-time data compression algorithms to reduce such data at high throughput to fit permanent storage has drawn increasing attention. Specifically, at the newly constructed sPHENIX experiment at the Relativistic Heavy Ion Collider (RHIC), a time projection chamber is used as the main tracking detector, which records particle trajectories in a volume of three-dimensional (3D) cylinder. The resulting data are usually very sparse with occupancy around 10.8%. Such sparsity presents a challenge to conventional learning-free lossy compression algorithms, such as SZ, ZFP, and MGARD. The 3D convolutional neural network (CNN)-based approach, Bicephalous Convolutional Autoencoder (BCAE), outperforms traditional methods both in compression rate and reconstruction accuracy. BCAE can also utilize the computation power of graphical processing units suitable for deployment in a modern heterogeneous highperformance computing environment. This work introduces two BCAE variants: BCAE++ and BCAE-2D. BCAE++ achieves a 15% better compression ratio and a 77% better reconstruction accuracy measured in mean absolute error compared with BCAE. BCAE-2D treats the radial direction as the channel dimension of an image, resulting in a 3× speedup in compression throughput. In addition, we demonstrate an unbalanced autoencoder with a larger decoder can improve reconstruction accuracy without significantly sacrificing throughput. Lastly, we observe both the BCAE++ and BCAE-2D can benefit more from using half-precision mode in throughput (76 - 79% increase) without loss in reconstruction accuracy. The source code and links to data and pretrained models can be found at https://github.com/BNL-DAQ-LDRD/NeuralCompression_v2

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Accelerate M-TIP on GPUs and deploy to Summit and NERSC-9 (against simulated data) WBS 2.2.4.05 ExaFEL, Milestone ADSE13-199

We evaluated the orientation matching step in the M-TIP SPI workflow for potential offloading to accelerators. We ported the code to GPUs, benchmarked it, optimized and down-selected the best versions. The accelerated version of the orientation matching code that was developed at LANL (LANL GPU v3) is 34-55X faster than sequential, 2.4-4.9X faster than the fastest OpenMP open source version we found (FAISS OpenMP) and 1.5-4X faster than the fastest GPU open source version we found (FAISS GPU). Summit single-node GPU versions were somewhat faster than Cori GPU. Image size plays a role; mid-range image sizes take more time. The LANL CUDA multi-node, multi-GPU implementation shows mostly linear strong scaling. I/O also plays a large role; splitting data into parts improves read time and burst buffers dramatically improve read times. This work will be integrated into the M-TIP workflow as part of the next milestone ADSE13-193.

97 MATHEMATICS AND COMPUTING↗

Optical to Near-infrared Transmission Spectrum of the Warm Sub-Saturn HAT-P-12b

We present the transmission spectrum of HAT-P-12b through a joint analysis of data obtained from the Hubble Space Telescope Space Telescope Imaging Spectrograph and Wide Field Camera 3 and Spitzer, covering the wavelength range 0.3–5.0 μm. We detect a muted water vapor absorption feature at 1.4 μm attenuated by clouds, as well as a Rayleigh scattering slope in the optical indicative of small particles. We interpret the transmission spectrum using both the state-of-the-art atmospheric retrieval code SCARLET and the aerosol microphysics model CARMA. These models indicate that the atmosphere of HAT-P-12b is consistent with a broad range of metallicities between several tens to a few hundred times solar, a roughly solar C/O ratio, and moderately efficient vertical mixing. Cloud models that include condensate clouds do not readily generate the submicron particles necessary to reproduce the observed Rayleigh scattering slope, while models that incorporate photochemical hazes composed of soot or tholins are able to match the full transmission spectrum. From a complementary analysis of secondary eclipses by Spitzer, we obtain measured depths of 0.042% ± 0.013% and 0.045% ± 0.018% at 3.6 and 4.5 μm, respectively, which are consistent with a blackbody temperature of 890{sup +60} {sub −70} K and indicate efficient day–night heat recirculation. HAT-P-12b joins the growing number of well-characterized warm planets that underscore the importance of clouds and hazes in our understanding of exoplanet atmospheres.

79 ASTRONOMY AND ASTROPHYSICS↗

Pediatric Computed Tomography. Radiation Dose in Abdominal Studies

Computed tomography is one of the most popular medical imaging modalities used in the last years. However, because is one of the techniques that delivered a considerable radiation dose, precautions should be taken into account. Pediatric patients are more radiosensitive than adults, and the probability that no desirable biological effects can occur is greater. To this, also it adds the probability that they will need more radiological studies in the future. The work consisted in determining the received dose by the pediatric patients undergoing abdominal studies in a multislice computed tomograph, according to the dosimetric quantities established by a Code of Practice published by the International Atomic Energy Agency; using a ionization chamber and a phantom that simulates the abdomen of a pediatric patient. The weighted air kerma index (C{sub w}) was 14.3{+-}0.4 mGy, this value is lower than the published by the American College of Radiology, 25 mGy. The multiple scan average dose (MSAD), which is a quantity established by the NOM-229-SSA1-2002 was determined, finding a value of 14.2{+-}0.1 mGy, it is also below the value established, 25 mGy for an adult study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diagnostics for fast ignition science (invited)

The ignition concept for electron fast ignition inertial confinement fusion requires sufficient energy be transferred from an {approx}20 ps laser pulse to the compressed fuel via approximately MeV electrons. We have assembled a suite of diagnostics to characterize such transfer, simultaneously fielding absolutely calibrated extreme ultraviolet multilayer imagers at 68 and 256 eV; spherically bent crystal imagers at 4.5 and 8 keV; multi-keV crystal spectrometers; MeV x-ray bremmstrahlung, electron and proton spectrometers (along the same line of sight), and a picosecond optical probe interferometer. These diagnostics allow careful measurement of energy transport and deposition during and following the laser-plasma interactions at extremely high intensities in both planar and conical targets. Together with accurate on-shot laser focal spot and prepulse characterization, these measurements are yielding new insights into energy coupling and are providing critical data for validating numerical particle-in-cell (PIC) and hybrid PIC simulation codes in an area crucial for fast ignition and other applications. Novel aspects of these diagnostics and how they are combined to extract quantitative data on ultrahigh intensity laser-plasma interactions are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement and modeling of the effect of support arm backscatter on dosimetry with a Varian EPID

Purpose: Amorphous silicon EPIDs have been used for planar dose verification in IMRT treatments for many years. The support arm used to attach some types of EPIDs to linear accelerators can introduce inaccuracies to dosimetry measurements due to the presence of metallic parts in their structures. It is demonstrated that this uncertainty may be as large as {approx}6% of maximum image signal for large fields. In this study, a method has been described to quantify, model and correct for the effect of backscattered radiation from the EPID support arm (E-Arm type, Varian Medical Systems). Methods: Measurements of a support arm backscatter kernel were made using several 1x1 cm{sup 2} 6 MV pencil beam irradiations at a sample of positions over the sensitive area of the EPID in standard clinical setup and repeated with the EPID removed from the support arm but at the same positions. A curve-fit to the subtraction of EPID response obtained on and off the arm was used to define the backscatter kernel. The measured kernel was compared with a backscatter kernel obtained by Monte Carlo simulations with EGS/BEAM code. A backscatter dose prediction using the measured backscatter kernel was added to an existing EPID dose prediction model. The improvement in the agreement of the modified model predictions with EPID measurements for a number of open fields and IMRT beams were investigated by comparison to the original model results. Results: Considering all functions tested to find the best functional fit to the data points, a broad Gaussian curve proved to be the optimum fit to the backscatter data. The best fit through the Monte Carlo simulated backscatter kernel was also found to be a Gaussian curve. The maximum decrease in normalized root mean squared deviation of the measured and modeled EPID image profiles for open fields was 13.7% for a 15x15 cm{sup 2} field with no decrease observed for a 3x3 cm{sup 2} (the smallest) field as it was not affected by the arm backscatter. Gamma evaluation (2%, 2 mm criteria) showed the improvement in agreement between the model and measurement results when the backscatter was incorporated. The average increase in Gamma pass rate was 2% for head and neck and 1.3% for prostate IMRT fields investigated in this study. Conclusions: The application of the backscatter kernel determined in this study improved the accuracy of dosimetry using a Varian EPID with E-arm for open fields of different sizes: Eight head and neck and seven prostate IMRT fields. Further improvement in the agreement between the model predictions and EPID measurements requires more sophisticated modeling of the backscatter.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Skeletal dosimetry in a voxel-based rat phantom for internal exposures to photons and electrons

Purpose: The skeleton makes a significant contribution to the whole body absorbed dose evaluation of rats, since the bone marrow and bone surface in the skeleton express high radiosensitivity and are considered to be important dose-limiting tissues. The bone marrow can be categorized as red bone marrow (RBM) and yellow bone marrow (YBM). It is important to investigate the bone marrow in skeletal dosimetry. Methods: Cryosectional color images of the skeleton of a 156 g rat were segmented into mineral bone (including cortical bone and trabecular bone), RBM, and YBM. These three tissue types were identified at 40 different bone sites and integrated into a previously developed voxel-based rat computational phantom. Photon and electron skeletal absorbed fractions were then calculated using the MCNPX Monte Carlo code. Results: Absorbed fraction (AF) and specific absorbed fraction (SAF) for mineral bone, RBM, and YBM at the 40 different bone sites were established for monoenergetic photon and electron sources placed in 18 organs and seven bone sites. Discrete photon energy was varied from 0.01 to 5.0 MeV in 21 discrete steps, while 21 discrete electron energies were studied, from 0.1 to 10.0 MeV. The trends and values found were consistent with the results of other researchers [M. G. Stabin, T. E. Peterson, G. E. Holburn, and M. A. Emmons, ''Voxel-based mouse and rat models for internal dose calculations,'' J. Nucl. Med. 47, 655-659 (2006)]. S-factors for the radionuclides {sup 169}Er, {sup 143}Pr, {sup 89}Sr, {sup 32}P, and {sup 90}Y, located in 18 organs and seven bone sites for the skeleton, were calculated and are provided in detail. Conclusions: For internal dose calculations, the AF data reveal that the mineral bone in the rat skeletal system is responsible for significant attenuation of gamma rays, especially at low energies. The photon SAF curves of RBM show that, for photon energies greater than 0.6 MeV, there is an increase in secondary photons emitted from the mineral bone as photon energy increases. The SAF values calculated in this study can also be used to determine the absorbed dose to the skeletal system of rats. The S-factors generated here will be useful in preclinical targeted radiotherapy experiments.

61 RADIATION PROTECTION AND DOSIMETRY↗

Failure Predictions for VHTR Core Components using a Probabilistic Contiuum Damage Mechanics Model

The proposed work addresses the key research need for the development of constitutive models and overall failure models for graphite and high temperature structural materials, with the long-term goal being to maximize the design life of the Next Generation Nuclear Plant (NGNP). To this end, the capability of a Continuum Damage Mechanics (CDM) model, which has been used successfully for modeling fracture of virgin graphite, will be extended as a predictive and design tool for the core components of the very high- temperature reactor (VHTR). Specifically, irradiation and environmental effects pertinent to the VHTR will be incorporated into the model to allow fracture of graphite and ceramic components under in-reactor conditions to be modeled explicitly using the finite element method. The model uses a combined stress-based and fracture mechanics-based failure criterion, so it can simulate both the initiation and propagation of cracks. Modern imaging techniques, such as x-ray computed tomography and digital image correlation, will be used during material testing to help define the baseline material damage parameters. Monte Carlo analysis will be performed to address inherent variations in material properties, the aim being to reduce the arbitrariness and uncertainties associated with the current statistical approach. The results can potentially contribute to the current development of American Society of Mechanical Engineers (ASME) codes for the design and construction of VHTR core components.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Analysis of Mis-Steered Electron Beam in the NSLS-II Storage Ring

This note reports the analysis of the mis-steered electron in the NSLS-II storage ring for the determination of supplementary shielding. The potential angles and offsets of the mis-steered beam are calculated by implementing the cascaded parameter scan (CPS) along the beam-line. This method is originally developed for the top-off safety analysis, and has been well documented in ref. The basic idea of CPS is to combine the phase space images due to different magnet set-points into one superset, then re-populate virtual particles on a fine grid as the input of the downstream magnet scanning. The purpose of re-population in phase space is to avoid the redundant particle tracking calculation due to the multi-layer overlap of different magnet settings. A parallel python code of implementing the tracking study has been written, and benchmarked with other top-off safety simulators developed in SLAC and LBNL.

36 MATERIALS SCIENCE↗

Design and Implementation of an In?Cache Archival Entropy Coder for the Sonoma Persistent Surveillance System

The Sonoma sensor, developed at Lawrence Livermore National Laboratory, is an electro-optical (EO) sensor composed of a tiled arrangement of cameras, where each camera sends 20 megabytes (MB) of raw data per frame. Depending on the sensor configuration, each sensor image, in aggregate, can total up to 320 MB. I discuss here the design and implementation of a high-speed entropy coder utilizing the Lead-1 encoding method, intended to quickly and losslessly compress sensor data before it is written to storage. More sophisticated (and slower) compression techniques may be performed off-line. The coder, favoring speed over coding efficiency, is simple in principle and tiny in practice: the amount of allocated memory required by the coder can be as small as 26 bytes. On a 2.7 GHz PowerMac G5 this coder is capable of encoding sensor data at a rate of 163 megabytes per second. The overall compression rate is better than that of BZIP2, GZIP, and a range coder, and the total execution speed is superior.

99 GENERAL AND MISCELLANEOUS↗

Multi-System Verification of Registrations for Image-Guided Radiotherapy in Clinical Trials

Purpose: To provide quantitative information on the image registration differences from multiple systems for image-guided radiotherapy (IGRT) credentialing and margin reduction in clinical trials. Methods and Materials: Images and IGRT shift results from three different treatment systems (Tomotherapy Hi-Art, Elekta Synergy, Varian Trilogy) have been sent from various institutions to the Image-Guided Therapy QA Center (ITC) for evaluation for the Radiation Therapy Oncology Group (RTOG) trials. Nine patient datasets (five head-and-neck and four prostate) were included in the comparison, with each patient having 1-4 daily individual IGRT studies. In all cases, daily shifts were re-calculated by re-registration of the planning CT with the daily IGRT data using three independent software systems (MIMvista, FocalSim, VelocityAI). Automatic fusion was used in all calculations. The results were compared with those submitted from institutions. Similar regions of interest (ROIs) and same initial positions were used in registrations for inter-system comparison. Different slice spacings for CBCT sampling and different ROIs for registration were used in some cases to observe the variation of registration due to these factors. Results: For the 54 comparisons with head-and-neck datasets, the absolute values of differences of the registration results between different systems were 2.6 {+-} 2.1 mm (mean {+-} SD; range 0.1-8.6 mm, left-right [LR]), 1.7 {+-} 1.3 mm (0.0-4.9 mm, superior-inferior [SI]), and 1.8 {+-} 1.1 mm (0.1-4.0 mm, anterior-posterior [AP]). For the 66 comparisons in prostate cases, the differences were 1.1 {+-} 1.0 mm (0.0-4.6 mm, LR), 2.1 {+-} 1.7 mm (0.0-6.6 mm, SI), and 2.0 {+-} 1.8 mm (0.1-6.9 mm, AP). The differences caused by the slice spacing variation were relatively small, and the different ROI selections in FocalSim and MIMvista also had limited impact. Conclusion: The extent of differences was reported when different systems were used for image registration. Careful examination and quality assurance of the image registration process are crucial before considering margin reduction using IGRT in clinical trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

R and DE Robotic Sensor Intern Team: Remote 3D Mapping Overview

The Department of Energy (DOE) nuclear complex includes many hazardous and challenging environments that must be inspected remotely and routinely for structural integrity evaluation and long-term planning purposes. The H-Canyon Air Exhaust (HCAEX) Tunnel biannual inspection is an example of such an environment. Presently inspections are performed by teleoperated robotic crawlers provide low resolution video feedback to the structural engineers. Advanced sensors such as Lidar and panospheric hi-res cameras have the potential to provide additional valuable data in future inspections. UT-Austin Lidar work in support of an H-Canyon deployment began with the DOE EM sponsored H-Canyon Integrated Research Project. The R and DE Robotic Sensor intern team includes two of the UT-Austin Masters students working on Lidar development to facilitate the pulling of university developed solutions to the field. The goal of this project is to develop a suite of sensors that could be used to gather advanced data in future HCAEX tunnel inspections. Of particular interest is the ability to map the tunnel walls at an accuracy that will allow for the comparison of two scans performed at different time periods to estimate the concrete erosion rate. Additionally, the development of the 3D point cloud in the GPS denied environment is the first step in being able to collect and overlay other 3D data such as radiation mapping. Project specific goals include: - Design and develop 3D mapping sensor suite. Merge Lidar point cloud with high res camera images Incorporate Inertial Measurement Unit (IMU) to assist with positioning. - Develop sensor software and user GUI Sensor data collection and integration software User GUI for reach back system. - Test solution on crawler in tunnel test bed Use crawler base similar to H-Canyon planned crawler Design and build test bed simulating tunnel conditions. To facilitate rapid sensor integration, software coding and user GUI development, the Robot Operating System (ROS) was employed as the development platform. ROS is a set of open source software libraries and tools that assist with the building of robot applications. ROS includes drivers for many sensors, state-of-the-art algorithms, and powerful developer tools. Sensors selected for the summer intern solution included assessment as to whether they possessed ROS drivers and associated sample code. Additionally, the ROS 3D Robot Visualizer (rviz) tool has been employed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Blending ToolKit: A simulation framework for evaluation of galaxy detection and deblending

We present an open source Python library for simulating overlapping (i.e., blended) images of galaxies and performing self-consistent comparisons of detection and deblending algorithms based on a suite of metrics. The package, named Blending Toolkit (BTK), serves as a modular, flexible, easy-to-install, and simple-to-use interface for exploring and analyzing systematic effects related to blended galaxies in cosmological surveys such as the Vera Rubin Observatory Legacy Survey of Space and Time (LSST). BTK has three main components: (1) a set of modules that perform fast image simulations of blended galaxies, using the open source image simulation package GalSim; (2) a module that standardizes the inputs and outputs of existing deblending algorithms; (3) a library of deblending metrics commonly defined in the galaxy deblending literature. In combination, these modules allow researchers to explore the impacts of galaxy blending in cosmological surveys. Additionally, BTK provides researchers who are developing a new deblending algorithm a framework to evaluate algorithm performance and make principled comparisons with existing deblenders. BTK includes a suite of tutorials and comprehensive documentation. The source code is publicly available on GitHub at https://github.com/LSSTDESC/BlendingToolKit.

79 ASTRONOMY AND ASTROPHYSICS↗

Using the Stix finite element RF code to investigate operation optimization of the ICRF antenna on Alcator C-Mod

Abstract As the Ion Cyclotron Radio Frequency range (ICRF) heating becomes more favorable in fusion devices, the urgency of predicting and mitigating impurity generation that arises from it becomes more pressing. In the ICRF regime, rectified Radio Frequency (RF) sheaths are known to form at antenna and material edges that influence negative effects like sputtering and a decrease in heating efficiency. Methods to mitigate the formation of these RF sheaths through RF image currents cancellation have been experimentally studied. A power-phasing scan done on Alcator C-Mod in which the amount of power on the two inner straps ( P in ) versus the total 4 straps ( P tot ) was varied showed a minimization of enhanced potentials between P in / P tot ∼ 0.7–0.9 while impurities were minimized for P in / P tot ∼ 0.5–0.8. New capabilities in the realm of representing the RF sheath numerically now allow for these experiments to be simulated. Given the size of the sheath relative to the scale of the device, it can be approximated as a Boundary Condition (BC). A new parallelized cold-plasma wave equation solver called Stix implements a non-linear sheath impedance model BC formulated by Myra et al (2015 Phys. Plasmas 22 062507) through the method of finite elements using the MFEM library [ http://mfem.org ]. It is seen that Stix shows qualitative agreement with the measured C-Mod enhanced potentials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗