Search NASA⌕ Search

SEARCH · Search NASA

Results for “interval analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Composition and structure of acid leached LiMn{sub 2-y}Ti{sub y}O{sub 4} (0.2<=y<=1.5) spinels

Lithium manganese titanium spinels, LiMn{sub 2-y}Ti{sub y}O{sub 4}, (0.2<=y<=1.5) have been synthesized by solid-state reaction between TiO{sub 2} (anatase), Li{sub 2}CO{sub 3} and MnCO{sub 3}. Li{sup +} was leached from the powdered reaction products by treatment in excess of 0.2 N HCl at 85 deg. C for 6 h, under reflux. The elemental composition of the acidic solution and solid residues of leaching has been determined by complexometric titration, atomic absorption spectroscopy and X-ray fluorescence analysis. Powder X-ray diffraction was used for structural characterization of the crystalline fraction of the solid residues. It has been found that the amount of Li{sup +} leached from LiMn{sub 2-y}Ti{sub y}O{sub 4} decreases monotonically with increasing y in the interval 0.2<=y<=1.0 and abruptly drops to negligibly small values for y>1.0. The content of Mn and Li in the liquid phase and of Mn and Ti in the solid (amorphous plus crystalline) residue, were related to the composition and cation distribution in the pristine compounds. A new formal chemical equation describing the process of leaching and a mechanism of the structural transformation undergone by the initial solids as a result of Li{sup +} removal has been proposed. - Graphical abstract: Schematic representation of the acid leaching of LiMn{sub 2-y}Ti{sub y}O{sub 4} (0.2<=y<=1.0).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Local Recurrence of Benign, Borderline, and Malignant Phyllodes Tumors of the Breast: A Systematic Review and Meta-analysis

Background: This systematic review and meta-analysis aimed to investigate local recurrence (LR) rates among the three grades (benign, borderline, and malignant) of phyllodes tumors (PTs). The study also assessed various risk factors for LR. Methods: Electronic articles published between 1 January 1995 and 31 May 2018, were searched and critically appraised. The authors independently reviewed the abstracts and extracted data for LR rates and LR risk factors. Results: The review incorporated 54 studies with 9234 individual cases. The pooled LR rates were 8% for benign, 13% for borderline, and 18% for malignant PTs. The risk of LR was significantly increased by borderline versus benign PTs (odds ratio [OR] 2.00; 95% confidence interval [CI] 1.68–2.38) and malignant versus borderline PTs (OR 1.28; 95% CI 1.05–1.55). The significant risk factors for LR were mitoses, tumor border (infiltrating vs. pushing), stromal cellularity (moderate/severe vs. mild), stromal atypia (severe vs. mild/absent), stromal overgrowth (severe vs. mild/absent), and tumor necrosis (positive vs. negative). Age and tumor size were not associated with LR risk. The subgroup analysis showed that breast-conserving surgery versus mastectomy and positive versus negative surgical margins were significantly associated with an increased LR risk only in malignant PTs. Conclusions: The risk of LR was significantly increased from benign to borderline to malignant PTs. Mitoses, tumor border, stromal cellularity, stromal atypia, stromal overgrowth, tumor necrosis, type of surgery, and surgical margin status may be risk factors for LR. Different management strategies could be considered for different PT grades.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of Parentage Assignment and DNA Genotyping to Validate Scale Analysis for Estimating Steelhead Age and Spawning History

Abstract Sound fisheries management depends on understanding life history characteristics, such as age at maturity, migration, and spawning history; hard parts, such as scales and otoliths, are commonly used to estimate values for these traits. Validation of these techniques is often difficult but critical because errors in mean values for a population can result in erroneous estimates of sustainable exploitation rates. In this study, we compared information on age and spawning history derived from genetic analysis with information from scale analysis for 1,836 individual steelhead Oncorhynchus mykiss representing two life history stages (smolt and mature adult); these fish were of hatchery and wild origin and were sampled from two rivers in Washington State over a period of 19 years. Aging error rates were less than 5% for both wild smolts and hatchery adults, but the error rate for wild adults was much higher (13%; 95% confidence interval [CI] = 1.82–29.22%). Adult scale ages were biased; scale readers typically overestimated the ages of younger fish and underestimated the ages of older fish. In addition to the errors in age estimation, repeat spawners were misclassified as virgin spawners 6.5% of the time (95% CI = 0.79–20.26%). The higher error rates obtained in using scales for aging and identifying repeat spawning in wild adults may partly stem from the more complex life history relative to that of smolts or hatchery-origin adults; these results highlight the need for verification of scale analysis, especially for wild steelhead populations.

Seamons, Todd R.↗

Gain and offset calibration reduces variation in exposure-dependent SNR among systems with identical digital flat-panel detectors

Purpose: The conditions under which vendor performance criteria for digital radiography systems are obtained do not adequately simulate the conditions of actual clinical imaging with respect to radiographic technique factors, scatter production, and scatter control. Therefore, the relationship between performance under ideal conditions and performance in clinical practice remains unclear. Using data from a large complement of systems in clinical use, the authors sought to develop a method to establish expected performance criteria for digital flat-panel radiography systems with respect to signal-to-noise ratio (SNR) versus detector exposure under clinical conditions for thoracic imaging. Methods: The authors made radiographic exposures of a patient-equivalent chest phantom at 125 kVp and 180 cm source-to-image distance. The mAs value was modified to produce exposures above and below the mAs delivered by automatic exposure control. Exposures measured free-in-air were corrected to the imaging plane by the inverse square law, by the attenuation factor of the phantom, and by the Bucky factor of the grid for the phantom, geometry, and kilovolt peak. SNR was evaluated as the ratio of the mean to the standard deviation (SD) of a region of interest automatically selected in the center of each unprocessed image. Data were acquired from 18 systems, 14 of which were tested both before and after gain and offset calibration. SNR as a function of detector exposure was interpolated using a double logarithmic function to stratify the data into groups of 0.2, 0.5, 1.0, 2.0, and 5.0 mR exposure (1.8, 4.5, 9.0, 18, and 45 {mu}Gy air KERMA) to the detector. Results: The mean SNR at each exposure interval after calibration exhibited linear dependence on the mean SNR before calibration (r{sup 2} = 0.9999). The dependence was greater than unity (m = 1.101 {+-} 0.006), and the difference from unity was statistically significant (p < 0.005). The SD of mean SNR after calibration also exhibited linear dependence on the SD of the mean SNR before calibration (r{sup 2} = 0.9997). This dependence was less than unity (m = 0.822 {+-} 0.008), and the difference from unity was also statistically significant (p < 0.005). Systems were separated into two groups: systems with a precalibration SNR higher than the median SNR (N = 7), and those with a precalibration SNR lower than the median SNR (N = 7). Posthoc analysis was performed to correct for expanded false positive results. After calibration, the authors noted differences in mean SNR within both high and low groups, but these differences were not statistically significant at the 0.05 level. SNR data from four additional systems and one system from those previously tested after replacement of its detector were compared to the 95% confidence intervals (CI) calculated from the postcalibration SNR data. The comparison indicated that four of these five systems were consistent with the CI derived from the previously tested 14 systems after calibration. Two systems from the paired group that remained outside the CI were studied further. One system was remedied with a grid replacement. The nonconformant behavior of the other system was corrected by replacing the image receptor. Conclusions: Exposure-dependent SNR measurements under conditions simulating thoracic imaging allowed us to develop criteria for digital flat-panel imaging systems from a single manufacturer. These measurements were useful in identifying systems with discrepant performance, including one with a defective grid, one with a defective detector, and one that had not been calibrated for gain and offset. The authors also found that the gain and offset calibration reduces variation in exposure-dependent SNR performance among the systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A time convolution less density matrix approach to the nonlinear optical response of a coupled system-bath complex

Time convolution less density matrix theory (TCL) is a powerful and well established tool to investigate strong system-bath coupling for linear optical spectra. We show that TCL equations can be generalised to the nonlinear optical response up to a chosen order in the optical field. This goal is achieved via an time convolution less perturbation scheme for the reduced density matrices of the electronic system. In our approach, the most important results are the inclusion of a electron-phonon coupling non-diagonal in the electronic states and memory effects of the bath: First, the considered model system is introduced. Second, the time evolution of the statistical operator is expanded with respect to the external optical field. This expansion is the starting point to explain how a TCL theory can treat the response up to in a certain order in the external field. Third, new TCL equations, including bath memory effects, are derived and the problem of information loss in the reduced density matrix is analysed. For this purpose, new dimensions are added to the reduced statistical operator to compensate lack of information in comparison with the full statistical operator. The theory is benchmarked with a two level system and applied to a three level system including non-diagonal phonon coupling. In our analysis of pump-probe experiments, the bath memory is influenced by the system state occupied between pump and probe pulse. In particular, the memory of the bath influences the dephasing process of electronic coherences developing during the time interval between pump and probe pulses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ion Association in AlCl3 Aqueous Solutions from Constrained First-Principles Molecular Dynamics

Ab initio molecular dynamics was used to investigate the ion pairing behavior between Cl- and the Al3+ ion in an aqueous AlCl3 solution containing 63 water molecules. A series of constrained simulations was carried out at 300 K for up to 16 ps each, by fixing the inter-nuclear separation (rAl-Cl) between the Al3+ ion and one of the Cl- ions. The calculated potential of mean force of the Al3+-Cl- ion pair shows a pronounced minimum at rAl-Cl = 2.3 Å corresponding to a contact ion pair (CIP). Two local minima assigned to solvent separated ion pairs (SSIP) are identified at rAl-Cl= 4.4 and 6.0 Å. The positions of the free energy minima coincide with the hydration shell intervals of the Al3+ cation suggesting that the Cl- ion is inclined to reside in regions of low concentration of waters, i.e. between the 1st and 2nd shells of Al3+ and between the 2nd shell and bulk. A detailed analysis of solvent structure around the Al3+ and Cl- ions as a function of rAl-Cl is presented. The results are compared to structure data from X-ray measurements and unconstrained AIMD simulations of single ions Al3+ and Cl- and AlCl3 solutions. The dipole moment of the water molecules inside the 1st and 2nd hydration shells of Al3+ and in the bulk region and those of the Clion were calculated as a function of rAl-Cl. Major changes in the electronic structure of the system result from the removal of Cl- from the 1st hydration shell of the Al3+ cation. Finally, two unconstrained AIMD simulations of aqueous AlCl3 solutions corresponding to CIP and SSIP configurations were performed (17 ps, 300 K). Only minor structural changes are observed in these systems, confirming their stability.

ab initio↗

Global soil profiles indicate depth-dependent soil carbon losses under a warmer climate

Soil organic carbon (SOC) changes under future climate warming are difficult to quantify in situ. Here we apply an innovative approach combining space-for-time substitution with meta-analysis to SOC measurements in 113,013 soil profiles across the globe to estimate the effect of future climate warming on steady-state SOC stocks. We find that SOC stock will reduce by 6.0 ± 1.6% (mean±95% confidence interval), 4.8 ± 2.3% and 1.3 ± 4.0% at 0–0.3, 0.3–1 and 1–2 m soil depths, respectively, under 1 °C air warming, with additional 4.2%, 2.2% and 1.4% losses per every additional 1 °C warming, respectively. The largest proportional SOC losses occur in boreal forests. Existing SOC level is the predominant determinant of the spatial variability of SOC changes with higher percentage losses in SOC-rich soils. Our work demonstrates that warming induces more proportional SOC losses in topsoil than in subsoil, particularly from high-latitudinal SOC-rich systems.

54 ENVIRONMENTAL SCIENCES↗

Ion temperature effects on the occurrence scattering time in dusty plasmas

The effects of ion temperature on the occurrence scattering time for the electron-dust grain collision are investigated in dusty plasmas. The Eikonal analysis is applied to obtain the scattering amplitude and occurrence scattering time for the electron-dust collision. It is found that the occurrence scattering time represents the oscillatory behavior. It is also found that the amplitude and oscillation interval of the occurrence scattering are enhanced with increasing collision energy. It is found that the ion temperature effect suppresses the occurrence scattering time in three-component dusty plasmas. It is also found that the density effect reduces the occurrence scattering time.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Kinetics of positive ions and electrically neutral active particles in afterglow in neon at low pressure

Kinetics of positive ions and electrically neutral active particles formed during breakdown and successive discharge in neon-filled tube at 6.6 millibars pressure had been analyzed. This analysis was performed on the basis of mean value of electrical breakdown time delay t{sup ¯}{sub d} dependence on afterglow period τ (memory curve). It was shown that positive ions are present in the 1μs < τ < 30 ms interval, which is manifested through t{sup ¯}{sub d} slow increase with the increase of τ. A rapid t{sup ¯}{sub d} increase in the 30 ms < τ < 3 s interval is a consequence of significant decrease of positive ions concentration and dominant role in breakdown initiation have ground state nitrogen atoms, which further release secondary electrons from the cathode by catalytic recombination process. These atoms are formed during discharge by dissociation of ground state nitrogen molecules that are present as impurities in neon. For τ > 3 s, breakdown is initiated by cosmic rays and natural radioactivity. The increase of discharge current leads to decrease of t{sup ¯}{sub d} due to the increase of positive ions concentration in inter electrode gap. The increase of applied voltage also decreases t{sup ¯}{sub d} for τ > 30 ms due to the increase of the probability for initial electron to initiate breakdown. The presence of UV radiation leads to the decrease of t{sup ¯}{sub d} due to the increased electron yield caused by photoelectrons. The influence of photoelectrons on breakdown initiation can be noticed for τ > 0.1 ms, while they dominantly determine t{sup ¯}{sub d} for τ > 30 ms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A NEAR-INFRARED SPECTROSCOPIC SURVEY OF K-SELECTED GALAXIES AT z{approx} 2.3: COMPARISON OF STELLAR POPULATION SYNTHESIS CODES AND CONSTRAINTS FROM THE REST-FRAME NIR

We present spectral energy distribution (SED) modeling of a sample of 34 K-selected galaxies at z{approx} 2.3. These galaxies have near-infrared (NIR) spectroscopy that samples the rest-frame Balmer/4000 A break as well as deep photometry in 13 broadband filters. New to our analysis is Infrared Array Camera (IRAC) data that extend the SEDs into the rest-frame NIR. Comparing parameters determined from SED fits with and without the IRAC data we find that the IRAC photometry significantly improves the confidence intervals of {tau}, A{sub v} , M {sub star}, and SFR for individual galaxies, but does not systematically alter the mean parameters of the sample. We use the IRAC data to assess how well current stellar population synthesis codes describe the rest-frame NIR SEDs of young galaxies where discrepancies between treatments of the thermally pulsating asymptotic giant branch phase of stellar evolution are most pronounced. The models of Bruzual and Charlot, Maraston, and Charlot and Bruzual all successfully reproduce the SEDs of our galaxies with {<=}5% differences in the quality of fit; however, the best-fit masses from each code differ systematically by as much as a factor of 1.5, and other parameters vary more, up to factors of 2-3. A comparison of best-fit stellar population parameters from different stellar population synthesis (SPS) codes, dust laws, and metallicities shows that the choice of SPS code is the largest systematic uncertainty in most parameters, and that systematic uncertainties are typically larger than the formal random uncertainties. The SED fitting confirms our previous result that galaxies with strongly suppressed SF account for {approx}50% of the K-bright population at z{approx} 2.3; however, the uncertainty in this fraction is large due to systematic differences in the specific star formation rates derived from the three SPS models.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurements of cross sections and charged pion spectra in proton-carbon interactions at 31 GeV/c

Interaction cross sections and charged pion spectra in p+C interactions at 31 GeV/c were measured with the large-acceptance NA61/SHINE spectrometer at the CERN SPS. These data are required to improve predictions of the neutrino flux for the T2K long-baseline neutrino oscillation experiment in Japan. A set of data collected during the first NA61/SHINE run in 2007 with an isotropic graphite target with a thickness of 4% of a nuclear interaction length was used for the analysis. The measured p+C inelastic and production cross sections are 257.2 {+-} 1.9 {+-} 8.9 and 229.3 {+-} 1.9 {+-} 9.0 mb, respectively. Inclusive production cross sections for negatively and positively charged pions are presented as functions of laboratory momentum in ten intervals of the laboratory polar angle covering the range from 0 up to 420 mrad. The spectra are compared with predictions of several hadron production models.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Relic gravitational waves in light of the 7-year Wilkinson Microwave Anisotropy Probe data and improved prospects for the Planck mission

The new release of data from Wilkinson Microwave Anisotropy Probe improves the observational status of relic gravitational waves. The 7-year results enhance the indications of relic gravitational waves in the existing data and change to the better the prospects of confident detection of relic gravitational waves by the currently operating Planck satellite. We apply to WMAP7 data the same methods of analysis that we used earlier [W. Zhao, D. Baskaran, and L. P. Grishchuk, Phys. Rev. D 80, 083005 (2009)] with WMAP5 data. We also revised by the same methods our previous analysis of WMAP3 data. It follows from the examination of consecutive WMAP data releases that the maximum likelihood value of the quadrupole ratio R, which characterizes the amount of relic gravitational waves, increases up to R=0.264, and the interval separating this value from the point R=0 (the hypothesis of no gravitational waves) increases up to a 2{sigma} level. The primordial spectra of density perturbations and gravitational waves remain blue in the relevant interval of wavelengths, but the spectral indices increase up to n{sub s}=1.111 and n{sub t}=0.111. Assuming that the maximum likelihood estimates of the perturbation parameters that we found from WMAP7 data are the true values of the parameters, we find that the signal-to-noise ratio S/N for the detection of relic gravitational waves by the Planck experiment increases up to S/N=4.04, even under pessimistic assumptions with regard to residual foreground contamination and instrumental noises. We comment on theoretical frameworks that, in the case of success, will be accepted or decisively rejected by the Planck observations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of ${{\mathrm{D}}^0}$, ${{\mathrm{D}}^+}$, ${{\mathrm{D}}^{*+}}$ and ${{\mathrm{D}}^+_{\mathrm{s}}}$ production in pp collisions at ${\sqrt{{\textit{s}}}~=~5.02~{\text {TeV}}}$ with ALICE

The measurements of the production of prompt D 0 , D + , D *+ , and D$_s^+$ mesons in proton–proton (pp) collisions at $\sqrt{s}$=5.02 TeV with the ALICE detector at the Large Hadron Collider (LHC) are reported. D mesons were reconstructed at mid-rapidity (|y| < 0.5) via their hadronic decay channels D 0 → K - $π$ + , D + → K - $π$ + $π$ + , D *+ → D 0 $π$ + → K - $π$ + $π$ + , D$_s^+$ → Φ$π$ + → K + K - $π$ + , and their charge conjugates. The production cross sections were measured in the transverse momentum interval 0 < $p$T < 36 GeV/$c$ for D 0 , 1 < $p$T < 36 GeV/$c$ for D + and D *+ , and in 2 < $p$T < 24 GeV/$c$ for D$_s^+$ mesons. Thanks to the higher integrated luminosity, an analysis in finer $p$T bins with respect to the previous measurements at $\sqrt{s}$ = 7 TeV was performed, allowing for a more detailed description of the cross-section $p$T shape. The measured $p$T differential production cross sections are compared to the results at √ s = 7 TeV and to four different perturbative QCD calculations. Its rapidity dependence is also tested combining the ALICE and LHCb measurements in pp collisions at $\sqrt{s}$ = 5.02 TeV. This measurement will allow for a more accurate determination of the nuclear modification factor in p–Pb and Pb–Pb collisions performed at the same nucleon– nucleon centre-of-mass energy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the Spin Correlation in the Top Quark Pair Production using the Dilepton Events in 1.96-TeV Proton-Antiproton Collisions

One of the most remarkable properties of the top quark is its extremely short lifetime, which allows us to observe the top quark spin at its production. That means a spin correlation at $t\bar{t}$ production is possible to be observed. In this thesis, we report on a measurement of the correlation coefficient between top quark spin and antitop quark spin in the beam basis at top quark pair production. We select $t\bar{t}$ pair production candidates by requiring two high transverse momentum leptons, two jets and large missing $E_T$ . In order to reconstruct the angular distribution of top quark decay products, we perform full kinematical reconstruction using predicted distributions of $p^{t\bar{t}}_z$ , $p^{t\bar{t}}_T$ and $M_{t\bar{t}}$. We make signal and background templates from admixture of Monte Carlo simulations and data-based background modelings. Then, we perform unbinned likelihood fit of angular distribution of data to signal and background templates and obtain result. This analysis is based on the data of 5.1 $fb^{-1}$ collected with the Collider Detector Facility (CDF) at the Fermilab Tevatron between March 2002 and June 2009. We observe 334 $t\bar{t}$ candidate events. We determine a confidence interval at 68% level for the correlation coefficient $\kappa$ to be -0.520 < $\kappa$ < 0.605 or $\kappa$ = $0.042^{+0.563}_{-0.562}$ on the assumption of $M_{top}$ = 172.5 GeV/$c^2$.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Remarks on the ATMAP Campaigns in November 1981 and May 1982 at Collm (52 Deg N, 15 Deg E)

The results given are based on daily nighttime L. F. wind measurements over Central Europe on three measuring paths at 179, 227, and 272 kHz. Absolute reflection height measurements were carried out for the first time in August 1982 so that values of the months of 1982 and 1983 have been taken for the campaigns in November 1981 and May 1982. The prevailing wind and the semidiurnal tidal wind components are calculated daily. Means of the month or means of parts of a month are formed for climatological investigations. A 24 hour analysis is not possible due to the very different reflection heights during the daytime and nighttime, even with measurements being carried out the whole ay long in the winter season. The critical examination of the choice of the measuring intervals selected is dependent on the visual angle. A wind ield change is observed over Central Europe very often around the 20th of November 1981 this wind field variation being in the core period and leading over to a more stable tidal wind.

Schminder, R.↗

Analysis of pressure-broadened ozone spectra in the 3 micron region

The Molecular Spectroscopy Lab at NASA-Langley has been involved in a long term effort to carefully characterize the infrared spectra of small molecules of atmospheric interest, including methane, water vapor, ozone, and their isotopic counterparts. High resolution gas phase infrared spectra are obtained using both a tunable diode laser system, and the McMath Fourier transform spectrometer at the Kitt Peak Solar Observatory. Spectra are obtained at various pressures and temperatures for pure gas samples, and for samples containing mixtures of the species of interest in nitrogen, oxygen, or air. From these spectra, using a nonlinear least squares fitting technique, spectral parameters of position, intensity, and half-width were determined for varying laboratory conditions that approximate atmospheric conditions experienced in remote sensing situations. These parameters are of interest in theoretical studies of these species, as well as in allowing more accurate interpretation of remote sensing data. The current work involves the analysis of a series of McMath FTIR spectra of ozone broadened by mixing with air, nitrogen, or oxygen. Each spectrum covers the region from 2396 to 4057/cm. Each vibrational band is analyzed by first diving its region into small intervals containing a few well isolated absorption lines of reasonable intensity. Each of these small intervals is fit by multiple iterations of the nonlinear least square program until residuals are minimized to a reasonable value which corresponds to the noise level of the measured spectrum. Intervals for the 3 nu(sub 3) ozone band in the region from 3000 to 3060 wavenumbers are being examined.

Prochaska, Eleanor S.↗

Viking 2 electron observations at Mars

An analysis of the electron mode sweeps made in Viking 2 above the ionosphere is presented. An observation of the electron energy spectrum over the range 0 to 78 eV was recorded in 1 s and observations were made at intervals of 4 or 8 s. The concentrations and temperatures were highly variable in the altitude range 14,000 to 9000 km. Evidence for two Maxwellian components were present in most of the records. The general trend of concentration and temperature for the predominant component was from 2/cu cm and 100,000 K at 15,600 km to 5/cu cm at 220,000 K and 900 km, in good agreement with the Mars 3 observations of Gringauz et al. (1974). The higher-temperature component was generally characterized by a temperature near 400,000 K and concentrations near 0.1/cu cm. The electron plasma pressures near 800 km were about a factor of 20 lower than those obtained from Viking 1, the difference being much greater than expected from the normal distribution around the stagnation point in the shocked solar wind.

Johnson, Francis S.↗

Toroidal wave frequency at L=6-10: AMPTE/CCE Observations and Comparison with Theoretical Model

Magnetospheric standing Alfven waves are guided along the ambient magnetic field and their frequency depends on the mass density of the plasma distributed along the field lines. These properties allow us to use Alfen waves to map time-dependent phenomena between space and ground and to estimate the mass density. In this paper we present a statistical study of the spatial variation of the fundamental frequency f(sub T1) of toroidal-mode standing Alfen waves in the L range from 6 to 10, where L indicates the maximum geocentric distance on the field line. The data used for this analysis are energetic particle flux anisotropy (proxy of transverse electric field) and magnetic field measurements from the Active Magnetospheric Particle Tracer Explorers Charge Composition Explorer (CCE) spacecraft. Using CCE data covering 4 years we obtained approximately 5000 20-min intervals containing a clear signature of toroidal waves. The median f(sub T1), is 6-10 mHz at L=7 and decreases to 4-8 mHz at L = . The frequency tends to be lower at noon than at midnight. The observed frequencies are compared with numerically derived frequencies using an empirical mass density model and a magnetic field model. We found a good agreement for 12-24 MLT but a large discrepancy near MLT= 3. This may indicate that the flux tubes at this local time are more heavily loaded than specified in the Gallagher et al. model.

Takahashi, Kazue↗