Search NASA⌕ Search

SEARCH · Search NASA

Results for “linear response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Conceptual design of ELM control coils for the TCABR tokamak

An upgrade of the Tokamak à Chauffage Alfvén Brésilien (TCABR) is being designed to make it capable of creating a well controlled environment where the impact of resonant magnetic perturbation (RMP) fields on edge localised modes can be addressed over a wide range of (i) plasma shapes, (ii) divertor configurations, (iii) RMP coil geometries and (iv) perturbed magnetic field spectra. To this end, a unique set of in-vessel RMP coils is being designed and, in this work, their conceptual design is presented. This unique set of coils is composed of three toroidal arrays of coils on the low field side and three toroidal arrays of coils on the high field side. Each of these six toroidal arrays is composed of 18 coils thus allowing for the creation of RMP fields with toroidal mode numbers n ≤ 9 and with increased control of the poloidal mode number spectrum. To study dynamical effects of RMP fields of different toroidal mode numbers, all rotating simultaneously with different velocities, each of the 108 RMP coils will be powered independently by power supplies that can provide voltages of up to 4 kV and electric currents of up to 2 kA, with frequencies varying continuously from 0Hz up to 10kHz. A set of physical criteria were used to determine the optimal coil geometry and their respective number of turns to reduce the coil currents and voltages during operation with alternate current. Further, the conceptual design was carried out using both the vacuum approach (no plasma response) and the single-fluid response approach, which accounts for the response of a linear, single-fluid, visco-resistive plasma calculated using the M3D-C 1 code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Differential adaptation of the linear and nonlinear components of the horizontal vestibuloocular reflex in squirrel monkeys

Previous work in squirrel monkeys has demonstrated the presence of linear and nonlinear components to the horizontal vestibuloocular reflex (VOR) evoked by high-acceleration rotations. The nonlinear component is seen as a rise in gain with increasing velocity of rotation at frequencies more than 2 Hz (a velocity-dependent gain enhancement). We have shown that there are greater changes in the nonlinear than linear component of the response after spectacle-induced adaptation. The present study was conducted to determine if the two components of the response share a common adaptive process. The gain of the VOR, in the dark, to sinusoidal stimuli at 4 Hz (peak velocities: 20-150 degrees /s) and 10 Hz (peak velocities: 20 and 100 degrees /s) was measured pre- and postadaptation. Adaptation was induced over 4 h with x0.45 minimizing spectacles. Sum-of-sines stimuli were used to induce adaptation, and the parameters of the stimuli were adjusted to invoke only the linear or both linear and nonlinear components of the response. Preadaptation, there was a velocity-dependent gain enhancement at 4 and 10 Hz. In postadaptation with the paradigms that only recruited the linear component, there was a decrease in gain and a persistent velocity-dependent gain enhancement (indicating adaptation of only the linear component). After adaptation with the paradigm designed to recruit both the linear and nonlinear components, there was a decrease in gain and no velocity-dependent gain enhancement (indicating adaptation of both components). There were comparable changes in the response to steps of acceleration. We interpret these results to indicate that separate processes drive the adaptation of the linear and nonlinear components of the response.

Non-NASA Center↗

The energy dependence and dose response of a commercial optically stimulated luminescent detector for kilovoltage photon, megavoltage photon, and electron, proton, and carbon beams

Optically stimulated luminescent detectors, which are widely used in radiation protection, offer a number of potential advantages for application in radiation therapy dosimetry. Their introduction into this field has been somewhat hampered by the lack of information on their radiation response in megavoltage beams. Here the response of a commercially available optically stimulated luminescent detector (OSLD) is determined as a function of energy, absorbed dose to water, and linear energy transfer (LET). The detector response was measured as a function of energy for absorbed doses from 0.5 to 4.0 Gy over the following ranges: 125 kVp to18 MV for photons, 6-20 MeV for electrons, 50-250 MeV for protons, and 290 MeV/u for the carbon ions. For the low LET beams, the response of the detector was linear up to 2 Gy with supralinearity occurring at higher absorbed doses. For the kilovoltage photons, the detector response relative to 6 MV increased with decreasing energy due to the higher atomic number of aluminum oxide (11.2) relative to water (7.4). For the megavoltage photons and electrons, the response was independent of energy. The response for protons was also independent of energy, but it was about 6% higher than its response to 6 MV photons. For the carbon ions, the dose response was linear for a given LET from 0.5 to 4.0 Gy, and no supralinearity was observed. However, it did exhibit LET dependence on the response relative to 6 MV photons decreasing from 1.02 at 1.3 keV/{mu}m to 0.41 at 78 keV/{mu}m. These results provide additional information on the dosimetric properties for this particular OSL detector and also demonstrate the potential for their use in photon, electron, and proton radiotherapy dosimetry with a more limited use in high LET radiotherapy dosimetry.

61 RADIATION PROTECTION AND DOSIMETRY↗

Linear and nonlinear interpretation of the direct strike lightning response of the NASA F106B thunderstorm research aircraft

The objective of the work reported here is to develop a methodology by which electromagnetic measurements of inflight lightning strike data can be understood and extended to other aircraft. A linear and time invariant approach based on a combination of Fourier transform and three dimensional finite difference techniques is demonstrated. This approach can obtain the lightning channel current in the absence of the aircraft for given channel characteristic impedance and resistive loading. The model is applied to several measurements from the NASA F106B lightning research program. A non-linear three dimensional finite difference code has also been developed to study the response of the F106B to a lightning leader attachment. This model includes three species air chemistry and fluid continuity equations and can incorporate an experimentally based streamer formulation. Calculated responses are presented for various attachment locations and leader parameters. The results are compared qualitatively with measured inflight data.

Rudolph, T. H.↗

Cellular effects of individual high-linear energy transfer particles and implications for tissue response at low doses

The energy deposition patterns produced by the radiation environment in space can be quite different from those in conventional radiation environments. Furthermore, conventional radiation biological experiments, using randomly distributed particle tracks, cannot access some variables which may be important in determining the health effects of irradiation. Controlled microbeam irradiation provides the means to investigate the effects and unique energy deposition patterns and cell environment for a variety of end points.

Non-NASA Center↗

Flapping response characteristics of hingeless rotor blades by a gereralized harmonic balance method

Linearized equations of motion for the flapping response of flexible rotor blades in forward flight are derived in terms of generalized coordinates. The equations are solved using a matrix form of the method of linear harmonic balance, yielding response derivatives for each harmonic of the blade deformations and of the hub forces and moments. Numerical results and approximate closed-form expressions for rotor derivatives are used to illustrate the relationships between rotor parameters, modeling assumptions, and rotor response characteristics. Finally, basic hingeless rotor response derivatives are presented in tabular and graphical form for a wide range of configuration parameters and operating conditions.

Peters, D. A.↗

Double ChemFET for the In-Line Monitoring of Silver Dosing in Potable Water Systems

With NASA Advanced Exploration Systems (AES) Life Support Systems (LSS)baselining ionic silver (Ag+) as the biocide of choice, development in silver monitoring technologies becomes necessary to monitor and control Ag+ release. Ion-selective field effect transistors (ISFETs) and chemically-sensitive field effect transistors (ChemFETs) are capable of selective detection of Ag+ with reversible and low detection limit responses. However, one major hurdle to ChemFET technologies is the requirement of a reference electrode, which can leak its fill solution into the potable water system and is prone to drift requiring frequent calibration. To circumvent this issue, a double chemically-sensitive field effect transistor (dChemFET) is proposed. The dChemFET uses a second ChemFET to selectively monitor the counter ion and serves in place of the reference electrode. This work reports on the development of the dChemFET, starting with the development of the Ag+ andNO3- ion selective membranes (ISMs) to be used in the ChemFETs. The Ag+ ISM was tested in 50-105 ppb Ag+ and showed linear, sub-Nernstian response. The NO3- ISM was tested in50-500 ppb silver ion equivalents of nitrate ion (Ag+ equiv. of NO3-) and shows linear, sub-Nernstian response as well . However, the Ag+ and NO3- ISMs face significant challenges in terms of drift that obstruct its application for long-term monitoring, but it can serve as a starting point for demonstrating the dChemFET proof of concept.

John Abdou↗

Flexible CO 2 Sensor Architecture with Selective Nitrogen Functionalities by One‐Step Laser‐Induced Conversion of Versatile Organic Ink

Abstract Nitrogen‐containing carbons (NC) are a class of sustainable materials for selective CO 2 adsorption. A versatile concept is introduced to fabricate flexible NC‐based sensor architectures for room‐temperature sensing of CO 2 in a one‐step laser conversion of primary films cast from abundant precursors. By the unidirectional energy impact in conjunction with depth‐dependent attenuation of the laser beam, a layered sensor heterostructure with a porous transducer and active sensor layer is formed. Comprehensive microscopic and spectroscopic cross‐sectional analyses confirm the preservation of the high content of imidazolic nitrogen in the sensor. The performance is optimized in terms of material morphology, chemical composition, and surface chemistry to achieve a linear relative resistive response of up to Δ R / R 0 = −14.3% (10% of CO 2 ). Thermodynamic analysis yields Δ ads H values of −35.6 and 34.1 kJ·mol −1 for H 2 O and CO 2 , respectively. The sensor is operable even in humid environments (e.g., ∆ R / R 0,RH = 80% = 0.53%) and shows good performance upon strong mechanical deformation.

flexible gas sensors↗

Optimal smoothing length scale for actuator line models of wind turbine blades based on Gaussian body force distribution: Wind energy, actuator line model

The actuator line model (ALM) is a commonly used method to represent lifting surfaces such as wind turbine blades within large-eddy simulations (LES). In the ALM, the lift and drag forces are replaced by an imposed body force that is typically smoothed over several grid points using a Gaussian kernel with some prescribed smoothing width e. To date, the choice of e has most often been based on numerical considerations related to the grid spacing used in LES. However, especially for finely resolved LES with grid spacings on the order of or smaller than the chord length of the blade, the best choice of e is not known. In this work, a theoretical approach is followed to determine the most suitable value of e, based on an analytical solution to the linearized inviscid flow response to a Gaussian force. We find that the optimal smoothing width eopt is on the order of 14%-25% of the chord length of the blade, and the center of force is located at about 13%-26% downstream of the leading edge of the blade for the cases considered. These optimal values do not depend on angle of attack and depend only weakly on the type of lifting surface. It is then shown that an even more realistic velocity field can be induced by a 2-D elliptical Gaussian lift-force kernel. Some results are also provided regarding drag force representation.

17 WIND ENERGY↗

Legacies of precipitation influence primary production in Panicum virgatum

Precipitation is a key driver of primary production worldwide, but primary production does not always track year-to-year variation in precipitation linearly. Instead, plant responses to changes in precipitation may exhibit time lags, or legacies of past precipitation. Legacies can be driven by multiple mechanisms, including persistent changes in plant physiological and morphological traits and changes to the physical environment, such as plant access to soil water. Here, we used three precipitation manipulation experiments in central Texas, USA to evaluate the magnitude, duration, and potential mechanisms driving precipitation legacies on aboveground primary production of the perennial C 4 grass, Panicum virgatum. Specifically, we performed a rainout shelter study, where eight genotypes grew under different precipitation regimes; a transplant study, where plants that had previously grown in a rainout shelter under different precipitation regimes were moved to a common environment; and a mesocosm study, where the effect of swapping precipitation regime was examined with a single genotype. Across these experiments, plants previously grown under wet conditions generally performed better than expected when exposed to drought. Panicum virgatum exhibited stronger productivity legacies of past wet years on current-year responses to drought than of past dry years on current-year responses to wet conditions. Additionally, previous year tiller counts, a proxy for meristem availability, were important in determining legacy effects on aboveground production. As climate changes and precipitation extremes—both dry and wet—become more common, these results suggest that populations of P. virgatum may become less resilient.

54 ENVIRONMENTAL SCIENCES↗

Data Science Techniques, Assumptions, and Challenges in Alloy Clustering and Property Prediction

Data analytics methods have been increasingly applied to understanding materials chemistry, processing due to the manufacturing approach, and uni-axial and cyclic property relationships in the highly complex space of alloy design. There are several benefits to applying data analytics to this space, including the ability to manage non-linearities in the responses of the alloy attributes and the resulting mechanical properties. However, key difficulties in applying and understanding the results of data analytics include the often lack of reported assumptions and data processing steps necessary to improve interpretation and reproducibility in derived results. In this work, the methods used to generate clustering and correlation analyses for experimental 9% Cr ferritic-martensitic steel data were investigated and the resulting implications for mechanical property predictions were assessed. This work uses principal component analysis, partitioning around medoids, t-SNE, and k-means clustering to investigate trends in composition, processing and microstructure information with creep and tensile properties, building on work done previously using a smaller version of the same dataset. The initial assumptions, preprocessing steps and methods are investigated and outlined in order to depict the fine level of detail required to convey the steps taken to process data and produce analytical results. Here, the variations in the resulting analyses are explored due to the influence of new and more varied data.

36 MATERIALS SCIENCE↗

Real-Time and Online Monitoring of Glucose Contents by Using Molecular Imprinted Polymer-Based IDEs Sensor

A highly sensitive, selective, reversible, and reusable glucose sensor is developed by using molecularly imprinted polymer-based artificial receptors onto interdigital transducer. Sensor receptors were synthesized through bulk imprinting technology by using styrene as monomer, ethylene glycol dimethacrylate (EGDMA) as cross-linker, and AIBN as free radical initiator. Topography of the synthesized receptors was investigated by scanning electron microscopy (SEM). Fabricated sensor showed concentration-dependent linear and reversible response with lower limit of detection of 30 ppb and upper limit of detection ~ 500 ppm. Furthermore, newly fabricated sensor is highly selective towards its analyte of interest in the presence of other competing agents, and the regeneration of sensor response has been assessed with the percentage error of less than 2% under the period of 1 year at room temperature and pressure conditions. The reported sensor may have potential technological applications in the field of medical diagnostics, food, and pharmaceutical industry.

60 APPLIED LIFE SCIENCES↗

Liquid microjunction surface sampling probe fluid dynamics: Characterization and application of an analyte plug formation operational mode

The recently discovered sample plug formation and injection operational mode of a continuous flow, coaxial tube geometry, liquid microjunction surface sampling probe (LMJ-SSP) (J. Am. Soc. Mass Spectrom, 2011) was further characterized and applied for concentration and mixing of analyte extracted from multiple areas on a surface and for nanoliter-scale chemical reactions of sampled material. A transparent LMJ-SSP was constructed and colored analytes were used so that the surface sampling process, plug formation, and the chemical reactions could be visually monitored at the sampling end of the probe before being analyzed by mass spectrometry of the injected sample plug. Injection plug peak widths were consistent for plug hold times as long as the 8 minute maximum attempted (RSD below 1.5%). Furthermore, integrated injection peak signals were not significantly different for the range of hold times investigated. The ability to extract and completely mix individual samples within a fixed volume at the sampling end of the probe was demonstrated and a linear mass spectral response to the number of equivalent analyte spots sampled was observed. Lastly, using the color and mass changing chemical reduction of the redox dye 2,6-dichlorophenol-indophenol with ascorbic acid, the ability to sample, concentrate, and efficiently run reactions within the same plug volume within the probe was demonstrated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phase field simulation of martensitic transformation in pre-strained nanocomposite shape memory alloys

We show in this paper how strain engineering alters the fundamental characteristic of a martensitic transformation (MT) and gives it a new set of properties including large quasi-linear elastic strain response with nearly vanishing hysteresis and low elastic modulus. The work is motivated and inspired by a recent experimental study on elastic and inelastic (transformation) strain matching in a pre-strained nano-composite with Nb nanowires embedded in a NiTi shape memory alloy matrix. In particular, we demonstrate by computer simulation that dislocations at Nb/NiTi interfaces produced by the pre-straining are responsible for the unprecedented properties. Microstructural evolution captured in the simulations reveals that local stress fields associated with the dislocations regulate the nucleation and growth of martensite, turning the otherwise sharp, strong first-order transition into a continuous, high-order like transition. The simulations predict that the stress-strain hysteresis and modulus of the composite decrease with increasing amount of pre-strain, which agrees well with the experimental measurement. This study suggests a design strategy by introducing non-uniform stress fields for enhanced properties of shape memory alloys.

36 MATERIALS SCIENCE↗

Instrumental noise estimates stabilize and quantify endothelial cell micro-impedance barrier function parameter estimates

A novel transcellular micro-impedance biosensor, referred to as the electric cell-substrate impedance sensor or ECIS, has become increasingly applied to the study and quantification of endothelial cell physiology. In principle, frequency dependent impedance measurements obtained from this sensor can be used to estimate the cell cell and cell matrix impedance components of endothelial cell barrier function based on simple geometric models. Few studies, however, have examined the numerical optimization of these barrier function parameters and established their error bounds. This study, therefore, illustrates the implementation of a multi-response Levenberg Marquardt algorithm that includes instrumental noise estimates and applies it to frequency dependent porcine pulmonary artery endothelial cell impedance measurements. The stability of cell cell, cell matrix and membrane impedance parameter estimates based on this approach is carefully examined, and several forms of parameter instability and refinement illustrated. Including frequency dependent noise variance estimates in the numerical optimization reduced the parameter value dependence on the frequency range of measured impedances. The increased stability provided by a multi-response non-linear fit over one-dimensional algorithms indicated that both real and imaginary data should be used in the parameter optimization. Error estimates based on single fits and Monte Carlo simulations showed that the model barrier parameters were often highly correlated with each other. Independently resolving the different parameters can, therefore, present a challenge to the experimentalist and demand the use of non-linear multivariate statistical methods when comparing different sets of parameters.

59 BASIC BIOLOGICAL SCIENCES↗

Shot noise sets the limit of quantification in electrochemical measurements

Detection of single molecules, particles, and rapid redox events is a challenge of electrochemical investigations and requires either an amplification strategy or significant averaging for the electrochemical current to exceed the noise level. We consider the minimum number of electrons required to reach the limit of quantification in these electrochemical measurements. A survey of the literature indicates that the state-of-the-art limit in current detection for different types of measurements (e.g. voltammetry, single-molecule redox cycling, ion channel recordings of single molecules, metal nanoparticle collision, and phase nucleation) is independent of the nature of the measurement and increases linearly with reciprocal response time, Δt -1 , over ~5 orders of magnitude (from ~10 to ~10 6 s -1 ). This paper demonstrates that the practical limit of quantification requires cumulative measurement of ~2100 electrons during Δt and is determined by statistics of counting electrons, that is, the shot noise in the current.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling brittle fracture due to anisotropic thermal expansion in polycrystalline materials

Here, this work investigated brittle fracture of polycrystalline materials due to thermal stresses arising from anisotropic thermal expansion. We used phase-field fracture simulations with the properties of alpha-uranium (α-U) and assumed a linear elastic mechanical response. Three-dimensional simulations were used to predict fracture for various conditions and crystallographic textures. We found that fracture was more pronounced during cooling than during heating because the anisotropy increased with temperature. We also found that the total crack surface area increased with increasing average misorientation, while the net shape change of the material decreased with increasing misorientation. Two-dimensional simulations in which one crystallographic coefficient of thermal expansion (CTE) was set to zero indicated that the expansion behavior in the crystallographic direction with the smallest CTE was the primary cause of fracture.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Feasibility Study of Glass Dosimeter for In Vivo Measurement: Dosimetric Characterization and Clinical Application in Proton Beams

Purpose: To evaluate the suitability of the GD-301 glass dosimeter for in vivo dose verification in proton therapy. Methods and Materials: The glass dosimeter was analyzed for its dosimetrics characteristic in proton beam. Dosimeters were calibrated in a water phantom using a stairlike holder specially designed for this study. To determine the accuracy of the glass dosimeter in proton dose measurements, we compared the glass dosimeter and thermoluminescent dosimeter (TLD) dose measurements using a cylindrical phantom. We investigated the feasibility of the glass dosimeter for the measurement of dose distributions near the superficial region for proton therapy plans with a varying separation between the target volume and the surface of 6 patients. Results and Discussion: Uniformity was within 1.5%. The dose-response has good linearity. Dose-rate, fading, and energy dependence were found to be within 3%. The beam profile measured using the glass dosimeter was in good agreement with the profile obtained from the ionization chamber. Depth-dose distributions in nonmodulated and modulated proton beams obtained with the glass dosimeter were estimated to be within 3%, which was lower than those with the ionization chamber. In the phantom study, the difference of isocenter dose between the delivery dose calculated by the treatment planning system and that measured by the glass dosimeter was within 5%. With in vivo dosimetry, the calculated surface doses overestimated measurements by 4%-16% using glass dosimeter and TLD. Conclusion: It is recommended that bolus be added for these clinical cases. We also believe that the glass dosimeter has considerable potential for use with in vivo patient proton dosimetry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗