Search NASA⌕ Search

SEARCH · Search NASA

Results for “load estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Integrated hydrogeophysical modelling and data assimilation for geoelectrical leak detection

Time-lapse electrical resistivity tomography (ERT) measurements provide indirect observations of hydrological processes in the Earth's shallow subsurface at high spatial and temporal resolution. ERT has been used in the past decades to detect leaks and monitor the evolution of associated contaminant plumes. Specifically, inverted resistivity images allow visualization of the dynamic changes in the structure of the plume. However, existing methods do not allow the direct estimation of leak parameters (e.g. leak rate, location, etc.) and their uncertainties. We propose an ensemble-based data assimilation framework that evaluates proposed hydrological models against observed time-lapse ERT measurements without directly inverting for the resistivities. Each proposed hydrological model is run through the parallel coupled hydro-geophysical simulation code PFLOTRAN-E4D to obtain simulated ERT measurements. The ensemble of model proposals is then updated using an iterative ensemble smoother. In this paper, we demonstrate the proposed framework on synthetic and field ERT data from controlled tracer injection experiments. Our results show that the approach allows joint identification of contaminant source location, initial release time, and solute loading from the cross-borehole time-lapse ERT data, alongside with an assessment of uncertainties in these estimates. We demonstrate a reduction in site-wide uncertainty by comparing the prior and posterior plume mass discharges at a selected image plane. This framework is particularly attractive to sites that have previously undergone extensive geological investigation (e.g., nuclear sites). It is well suited to complement ERT imaging and we discuss practical issues in its application to field problems.

58 GEOSCIENCES↗

Real-Time Implementation of Smart Wireless Charging of On-Demand Shuttle Service for Demand Charge Mitigation

This paper presents a smart charge management strategy for an on-demand electric shuttle operating at the National Renewable Energy Laboratory (NREL) campus and supported by an inductive charger at the vehicle's waiting spot. A new control algorithm has been proposed for mitigating the demand charges incurred from the wireless charger. It monitors the shuttle, wireless charger, renewable energy generation, and other loads and regulates charging behavior for demand charge mitigation. Within the control algorithm, an energy prediction is made to estimate the mobility needs of the vehicle and maintain uninterrupted service during operation while still minimizing peak demand. The proposed controller is designed and optimized using a Simulink model for the entire system. It is then implemented and tested in real time at the NREL campus using online cloud services. Two vehicle-use cases' charge-sustaining and charge-depletion operation' are tested under different campus power profiles and drive cycles to assess the controller's performance. In this work, the proposed controller showed a robust performance under different driving scenarios, with high correlation between simulation and experimental data. The results show that proper demand response can be achieved, with an average of 94% reduction of charging loads during peak demand events.

33 ADVANCED PROPULSION SYSTEMS↗

SU-E-T-388: Estimating the Radioactivity Inventory of a Cyclotron Based Pencil Beam Proton Therapy Facility

Purpose: Parts of the cyclotron and energy degrader are incidentally activated by protons lost during the acceleration and transport of protons for radiation therapy. An understanding of the radioactive material inventory is needed when regulatory requirements are assessed. Methods: First, the tumor dose and volume is used to determine the required energy deposition. For spot scanning, the tumor length along the beam path determines the number of required energy layers. For each energy layer the energy deposition per proton can be calculated from the residual proton range within the tumor. Assuming a typical layer weighting, an effective energy deposition per proton can then be calculated. The total number of required protons and the number of protons per energy layer can then be calculated. For each energy layer, proton losses in the energy degrader are calculated separately since its transmission efficiency, and hence the amount of protons lost, is energy dependent. The degrader efficiency also determines the number of protons requested from the cyclotron. The cyclotron extraction efficiency allows a calculation of the proton losses within the cyclotron. The saturation activity induced in the cyclotron and the degrader is equal to the production rate R for isotopes whose half-life is shorter that the projected cyclotron life time. R can be calculated from the proton loss rate and published production cross sections. Results: About 1/3 of the saturation activity is produced in the cyclotron and 2/3 in the energy degrader. For a projected case mix and a patient load of 1100 fractions per week at 1.8 Gy per fraction a combined activity of 180 mCi was estimated at saturation. Conclusion: Calculations were used to support to application of a radioactive materials license for the possession of 200 mCi of activity for isotopes with atomic numbers ranging from 1-83.

07 ISOTOPE AND RADIATION SOURCES↗

Estimation of cardiac reserve by peak power: validation and initial application of a simplified index

OBJECTIVES: To validate a simplified estimate of peak power (SPP) against true (invasively measured) peak instantaneous power (TPP), to assess the feasibility of measuring SPP during exercise and to correlate this with functional capacity. DESIGN: Development of a simplified method of measurement and observational study. SETTING: Tertiary referral centre for cardiothoracic disease. SUBJECTS: For validation of SPP with TPP, seven normal dogs and four dogs with dilated cardiomyopathy were studied. To assess feasibility and clinical significance in humans, 40 subjects were studied (26 patients; 14 normal controls). METHODS: In the animal validation study, TPP was derived from ascending aortic pressure and flow probe, and from Doppler measurements of flow. SPP, calculated using the different flow measures, was compared with peak instantaneous power under different loading conditions. For the assessment in humans, SPP was measured at rest and during maximum exercise. Peak aortic flow was measured with transthoracic continuous wave Doppler, and systolic and diastolic blood pressures were derived from brachial sphygmomanometry. The difference between exercise and rest simplified peak power (Delta SPP) was compared with maximum oxygen uptake (VO(2)max), measured from expired gas analysis. RESULTS: SPP estimates using peak flow measures correlated well with true peak instantaneous power (r = 0.89 to 0.97), despite marked changes in systemic pressure and flow induced by manipulation of loading conditions. In the human study, VO(2)max correlated with Delta SPP (r = 0.78) better than Delta ejection fraction (r = 0.18) and Delta rate-pressure product (r = 0.59). CONCLUSIONS: The simple product of mean arterial pressure and peak aortic flow (simplified peak power, SPP) correlates with peak instantaneous power over a range of loading conditions in dogs. In humans, it can be estimated during exercise echocardiography, and correlates with maximum oxygen uptake better than ejection fraction or rate-pressure product.

Non-NASA Center↗

Deep Electrification Analysis: The Role of the U.S. Power Grid for Sustainable Transportation

This project attempts to quantify the size of electric generation for the entire nation to transition from a fossil fuel based transportation sector to a zero GHG emission-based energy source. The scope of this analysis is limited to decarbonizing the transportation sector, leaving the remaining sectors, such as power (for those that are still fossil based), industry, and building sectors, for later phases of study. The study year for this analysis is 2050, with expected escalation in transportation services and naturally occurring evolutions in the electric power sector and the entire economy. This analysis uses the projections of the Energy Information Administration’s (EIA’s) Annual Energy Outlook (AEO 2020) Reference Case for study year 2050 [EIA/AEO2020] as a base-case. The transportation sector is disaggregated by the following modes and classes: (1) on-road (divided into light-duty, medium-duty, heavy-duty vehicles), (2) aviation, (3) maritime, and (4) rail. The decarbonization case was based on only 2 pathways: (1) electrification of on-road transportation except for 30% of heavy-duty vehicles, and (2) power-to-liquid for the remaining transportation modes. The study estimated for 11 US regions what the additional wind and storage capacities requirements are to replace the fossil-based fuels with renewable wind capacity. Considered were the utilization of the existing idle capacity particularly during the load valley at night and any additional new generation capacity in EIA projections for the reference case. To balance the additional wind capacity required significant energy storage capabilities which were estimated in terms of power capacity (GW) and energy capacity (GWh). The paper further characterizes the energy requirements by a relation of power capacity to duration, allowing the analyst to gain insights into what the best technology portfolio might be to meet the new balancing or flexibility needs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The decay of HIV under anti-retroviral therapy is biphasic even in humanized mice with just T cells

HIV-1 plasma viral load decays in a biphasic manner during antiretroviral therapy (ART). It was hypothesized that this is due to infection of different cell types, namely CD4+ T cells and macrophages. We studied this possibility directly by modeling the decay of HIV-1 in humanized mice. We utilized previously published data from humanized T-cell only mice (TOM) and myeloid-only mice (MOM) infected with HIV-1 and treated with a potent ART regimen. Viral load decay dynamics were modeled using either a single or a biexponential decay fitted using nonlinear mixed effects techniques. Fits were compared using the corrected Bayesian information criterion (BICc). In TOM, the biphasic model was significantly better than a single-phase decay model (ΔBICc ≈ 16) despite additional parameters. In MOM, the biphasic decay was statistically better, but there was substantial uncertainty because the virus goes below detection very fast. The first-phase half-life was consistent between groups (1.2 days in MOM and 1.3 days in TOM) and similar to the half-life estimated in human infection. The second-phase decay in these mice was minimal likely due to low initial viral loads. Additional analyses with mice containing both CD4+ T cells and macrophages or X4-tropic virus-infected MOM mice confirmed the biphasic pattern, demonstrating the robustness of this result. The biphasic decline in HIV-1 occurs, even with only CD4+ T cells, refuting the hypothesis that distinct cell populations (CD4+ T cells and macrophages) drive each decay phase. These findings support an alternative model in which the observed dynamics arise from intrinsic properties of the viral infection lifecycle rather than from cellular compartmentalization.

59 BASIC BIOLOGICAL SCIENCES↗

Aggregated Residential Load Modeling Using Dynamic Bayesian Networks

Abstract—It is already obvious that the future power grid will have to address higher demand for power and energy, and to incorporate renewable resources of different energy generation patterns. Demand response (DR) schemes could successfully be used to manage and balance power supply and demand under operating conditions of the future power grid. To achieve that, more advanced tools for DR management of operations and planning are necessary that can estimate the available capacity from DR resources. In this research, a Dynamic Bayesian Network (DBN) is derived, trained, and tested that can model aggregated load of Heating, Ventilation, and Air Conditioning (HVAC) systems. DBNs can provide flexible and powerful tools for both operations and planing, due to their unique analytical capabilities. The DBN model accuracy and flexibility of use is demonstrated by testing the model under different operational scenarios.

Bayesian↗

An improved Armstrong–Frederick-Type Plasticity Model for Stable Cyclic Stress–Strain Responses Considering Nonproportional Hardening

This paper modified an Armstrong–Frederick-type plasticity model for investigating the stable cyclic deformation behavior of metallic materials with different sensitivity to nonproportional loadings. In the modified model, the nonproportionality factor and nonproportional cyclic hardening coefficient coupled with the Jiang–Sehitoglu incremental plasticity model were used to estimate the stable stress–strain responses of the two materials (1045HR steel and 304 stainless steel) under various tension–torsion strain paths. A new equation was proposed to calculate the nonproportionality factor on the basis of the minimum normal strain range. Procedures to determine the minimum normal strain range were presented for general multiaxial loadings. Then, the modified model requires only the cyclic strain hardening exponent and cyclic strength coefficient to determine the material constants. It is convenient for predicting the stable stress–strain responses of materials in engineering application. Comparisons showed that the modified model can reflect the effect of nonproportional cyclic hardening well.

36 MATERIALS SCIENCE↗

Stochastic simulation of pulverized coal (PC) processes

An increasing population and electricity demand in the U.S. require capacity expansion of power systems. The National Energy Technology Laboratory (NETL), U.S. Department of Energy (DOE), has invested considerable efforts on research and development to improve the design and simulation of these power plants. Incorporation of novel process synthesis techniques and realistic simulation methodologies yield optimal flowsheet configurations and accurate estimation of their performance parameters. To provide a better estimation of such performance indicators, simulation models should predict the process behavior based on not only deterministic values of well-known input parameters but also uncertain variables associated with simulation assumptions. In this work, the stochastic simulation of a load-following pulverized coal (PC) power plant takes into account the variation of three input variables, namely, atmospheric air temperature, atmospheric air humidity, and generation load. These uncertain variables are characterized with probability density functions (pdfs) obtained from available atmospheric and electrical energy generation data. The stochastic simulation is carried out by obtaining a sample of values from the pdfs that generates a set of scenarios under which the model is run. An efficient sampling technique [Hammersley sequence sampling (HSS)] guarantees a set of scenarios uniformly distributed throughout the uncertain variable range. Then, each model run generates results on performance parameters as cycle efficiency, carbon emissions, sulfur emissions, and water consumption that are statistically analyzed after all runs are completed. Among these parameters, water consumption is of importance because an increasing demand has been observed mostly in arid regions of the country and, therefore, constrains the operability of the processes. This water consumption is significantly affected by atmospheric uncertainties. The original deterministic process model simulation was designed in Aspen Plus, and a CAPE-OPEN compliant stochastic simulation capability is employed to run the uncertainty analysis. Initially, the influences of atmospheric conditions and load change on the performance parameters are analyzed separately to understand their individual influences on the process, and then their simultaneous variation is analyzed to generate more realistic estimations of the process performance.

97 MATHEMATICS AND COMPUTING↗

Determination of Radiative Forcing of Saharan Dust using Combined TOMS and ERBE Data

The direct radiative forcing of Saharan dust aerosols has been determined by combining aerosol information derived from Nimbus-7 TOMS with radiation measurements observed at the top of atmosphere (TOA) by NOAA-9 ERBE made during February-July 1985. Cloud parameters and precipitable water derived from the NOAA-9 HIRS2 instrument were used to aid in screening for clouds and water vapor in the analyses. Our results indicate that under "cloud-free" and "dry" conditions there is a good correlation between the ERBE TOA outgoing longwave fluxes and the TOMS aerosol index measurements over both land and ocean in areas under the influence of airborne Saharan dust. The ERBE TOA outgoing shortwave fluxes were also found to correlate well with the dust loading derived from TOMS over ocean. However, the calculated shortwave forcing of Saharan dust aerosols is very weak and noisy over land for the range of solar zenith angle viewed by the NOAA-9 ERBE in 1985. Sensitivity factors of the TOA outgoing fluxes to changes in aerosol index were estimated using a linear regression fit to the ERBE and TOMS measurements. The ratio of the shortwave-to-longwave response to changes in dust loading over the ocean is found to be roughly 2 to 3, but opposite in sign. The monthly averaged "clear-sky" TOA direct forcing of airborne Saharan dust was also calculated by multiplying these sensitivity factors by the TOMS monthly averaged "clear-sky" aerosol index. Both the observational and theoretical analyses indicate that the dust layer height, ambient moisture content as well as the presence of cloud all play an important role in determining the TOA direct radiative forcing due to mineral aerosols.

Hsu, N. Christina↗

Field data collection of miscellaneous electrical loads in Northern California: Initial results

This report describes efforts to measure energy use of miscellaneous electrical loads (MELs) in 880 San Francisco Bay Area homes during the summer of 2012. Ten regions were selected for metering: Antioch, Berkeley, Fremont, Livermore, Marin County (San Rafael, Novato, Fairfax, and Mill Valley), Oakland/Emeryville, Pleasanton, Richmond, San Leandro, and Union City. The project focused on three major categories of devices: entertainment (game consoles, set-top boxes, televisions and video players), home office (computers, monitors and network equipment), and kitchen plug-loads (coffee/espresso makers, microwave ovens/toaster ovens/toasters, rice/slow cookers and wine chillers). These categories were important to meter because they either dominated the estimated overall energy use of MELs, are rapidly changing, or there are very little energy consumption data published. A total of 1,176 energy meters and 143 other sensors were deployed, and 90% of these meters and sensors were retrieved. After data cleaning, we obtained 711 valid device energy use measurements, which were used to estimate, for a number of device subcategories, the average time spent in high power, low power and “off” modes, the average energy use in each mode, and the average overall energy use. Consistent with observations made in previous studies, we find on average that information technology (IT) devices (home entertainment and home office equipment) consume more energy (15.0 and 13.0 W, respectively) than non-IT devices (kitchen plug-loads; 4.9 W). Opportunities for energy savings were identified in almost every device category, based on the time spent in various modes and/or the power levels consumed in those modes. Future reports will analyze the collected data in detail by device category and compare results to those obtained from prior studies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cost projections for Redox Energy storage systems

A preliminary design and system cost analysis was performed for the redox energy storage system. A conceptual design and cost estimate was prepared for each of two energy applications: (1) electric utility 100-MWh requirement (10-MW for ten hours) for energy storage for utility load leveling application, and (2) a 500-kWh requirement (10-kW for 50 hours) for use with a variety of residential or commercial applications, including stand alone solar photovoltaic systems. The conceptual designs were based on cell performance levels, system design parameters, and special material costs. These data were combined with estimated thermodynamic and hydraulic analysis to provide preliminary system designs. Results indicate that the redox cell stack to be amenable to mass production techniques with a relatively low material cost.

Michaels, K.↗

Evaluating Demand Response Impacts on Capacity Credit of Renewable Distributed Generation in Smart Distribution Systems

Environmental concerns and depletion of traditional energy lead to the booming development of renewable distributed generation (RDG) in the past decade. However, due to intermittent nature of renewable energy sources, to what extent RDG could provide capacity to power systems becomes a critical issue to the utility company when implementing long-term system strategic (generation expansion) planning. On the other hand, in a smart-grid frame, the popularization of different varieties of demand-side resources enables the system to operate at more flexible modes ever before. The potential variability in load demand not only introduces additional dynamics and uncertainties to the system, but could also affect the reliability benefits of RDG. Therefore, in practice, to effectively estimate the reliability value of RDG in power systems, the potential interaction between generation- and demand-side must be properly captured. In this paper, a study to assess the capacity credit (CC) of RDG in a context of distributed generation system is performed with consideration of the impacts of demand response (DR). A compound reliability model for DR is presented, which considers the uncertainties involved in both instant response and follow-on load recovery processes. On this basis, an assessment framework for the CC of RDG based on sequential Monte Carlo simulation is developed by which the inter-temporal characteristics of DR resources can be fully captured. The numerical study is implemented based on the IEEE-38 bus test case. The calculation results demonstrate that the CC of RDG would depend on a variety of factors, including penetration level, responsiveness of load demand and the correlations between RDG and DR availability. Also, it is shown that accounting for the underlying effect of DR is of absolute importance, otherwise the CC of RDG might be estimated erroneously in real practices.

capacity credit↗

A Practical Analysis Framework for Assessment of Printed Circuit Heat Exchangers in High-Temperature Nuclear Service

Abstract Printed circuit heat exchangers (PCHEs) have high thermal efficiency because of the numerous minuscule channels. These minuscule channels result in a high thermal exchange area per unit volume, making PCHE a top contender for an intermediate heat exchanger (IHX) in high-temperature reactors. Thousands of minuscule channels make finite element analysis of the PCHE computationally infeasible. A two-dimensional analysis is usually performed for the PCHE core, which cannot simulate the local channel level responses reasonably because of the absence of global constraint influence. At present, there is no analysis technique available in the ASME Code or literature that is computationally efficient and suitable for engineers to estimate PCHE local responses. A novel but practical two-step analysis framework is proposed for performing PCHE analysis. In the first step, the channeled core is replaced by orthotropic solids with similar stiffness to simulate the global thermomechanical elastic responses of the PCHE. In the second step, local submodel analysis with detailed channel geometry and loading is performed using the elastic-perfectly plastic (EPP) material model. The proposed two-step analysis technique provides a unique capability to estimate the channel corner responses to be used for PCHE performance assessment. This study first developed a methodology for calculating the elastic orthotropic properties of the PCHE core. Next, the two-step analysis is performed for a realistic size PCHE core, and different issues observed in the results are scrutinized and resolved. Finally, a practical finite element analysis framework for PCHEs in high-temperature nuclear service is recommended.

Engineering↗

Transportation Cask for Bare High Burnup Used Nuclear Fuel - 16362

A conceptual design for a reusable transportation cask (the 6625B-HB) capable of transporting boiling water reactor (BWR) and pressurized water reactor (PWR) used nuclear fuel (UNF) assemblies, including high burnup UNF, was produced for the Department of Energy (DOE) by AREVA. This cask could be configured to ship these assemblies either as bare fuel or fuel loaded into single-assembly damaged fuel cans (DFCs). The 6625B-HB cask has been designed with reasonable assurance it can be certified by the Nuclear Regulatory Commission (NRC) under 10 CFR Part 71 based on AREVA TN's experience with the MP197HB (a transportation cask designed to ship high burnup UNF in a dry storage canister), fabricated within existing facilities, used by most utilities, and transported by rail. The level of detail developed for the 6625B-HB is intended to support analyses and planning activities that DOE is performing in laying the groundwork for an integrated waste management system, which includes preparing for future large-scale transport of UNF to consolidated interim storage or disposal facilities. The details of the conceptual design include cask characteristics (e.g., capacity, dimensions, and masses), characteristics of the UNF that could be shipped in this cask system concept, estimates of costs to fabricate this cask system, an assessment of operational activity durations and associated cumulative doses for loading and unloading this cask system, and identification of potential limitations or anticipated licensing considerations of relevance for this cask system. This design concept for a reusable transportation cask would enhance the high-burnup fuel assembly carrying capacity as compared to other NRC-certified transportation casks and, unlike welded canister systems, could be used for shipment of bare UNF assemblies taken directly from reactor spent fuel pools (SFPs). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Successful Case Study of Small Business Energy Efficiency and Demand Response with Communicating Thermostats

This report documents a field study of 78 small commercial customers in the Sacramento Municipal Utility District service territory who volunteered for an integrated energy-efficiency/demand-response (EE-DR) program in the summer of 2008. The original objective for the pilot was to provide a better understanding of demand response issues in the small commercial sector. Early findings justified a focus on offering small businesses (1) help with the energy efficiency of their buildings in exchange for occasional load shed, and (2) a portfolio of options to meet the needs of a diverse customer sector. To meet these expressed needs, the research pilot provided on-site energy efficiency advice and offered participants several program options, including the choice of either a dynamic rate or monthly payment for air-conditioning setpoint control. Overall results show that pilot participants had energy savings of 20%, and the potential for an additional 14% to 20% load drop during a 100 F demand response event. In addition to the efficiency-related bill savings, participants on the dynamic rate saved an estimated 5% on their energy costs compared to the standard rate. About 80% of participants said that the program met or surpassed their expectations, and three-quarters said they would probably or definitely participate again without the $120 participation incentive. These results provide evidence that energy efficiency programs, dynamic rates and load control programs can be used concurrently and effectively in the small business sector, and that communicating thermostats are a reliable tool for providing air-conditioning load shed and enhancing the ability of customers on dynamic rates to respond to intermittent price events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Delivered dose uncertainty analysis at the tumor apex for ocular brachytherapy

Purpose: To estimate the total dosimetric uncertainty at the tumor apex for ocular brachytherapy treatments delivered using 16 mm Collaborative Ocular Melanoma Study (COMS) and Super9 plaques loaded with {sup 125}I seeds in order to determine the size of the apex margin that would be required to ensure adequate dosimetric coverage of the tumor. Methods: The total dosimetric uncertainty was assessed for three reference tumor heights: 3, 5, and 10 mm, using the Guide to the expression of Uncertainty in Measurement/National Institute of Standards and Technology approach. Uncertainties pertaining to seed construction, source strength, plaque assembly, treatment planning calculations, tumor height measurement, plaque placement, and plaque tilt for a simple dome-shaped tumor were investigated and quantified to estimate the total dosimetric uncertainty at the tumor apex. Uncertainties in seed construction were determined using EBT3 Gafchromic film measurements around single seeds, plaque assembly uncertainties were determined using high resolution microCT scanning of loaded plaques to measure seed positions in the plaques, and all other uncertainties were determined from the previously published studies and recommended values. All dose calculations were performed using PLAQUESIMULATOR v5.7.6 ophthalmic treatment planning system with the inclusion of plaque heterogeneity corrections. Results: The total dosimetric uncertainties at 3, 5, and 10 mm tumor heights for the 16 mm COMS plaque were 17.3%, 16.1%, and 14.2%, respectively, and for the Super9 plaque were 18.2%, 14.4%, and 13.1%, respectively (all values with coverage factor k = 2). The apex margins at 3, 5, and 10 mm tumor heights required to adequately account for these uncertainties were 1.3, 1.3, and 1.4 mm, respectively, for the 16 mm COMS plaque, and 1.8, 1.4, and 1.2 mm, respectively, for the Super9 plaque. These uncertainties and associated margins are dependent on the dose gradient at the given prescription depth, thus resulting in the changing uncertainties and margins with depth. Conclusions: The margins determined in this work can be used as a guide for determining an appropriate apex margin for a given treatment, which can be chosen based on the tumor height. The required margin may need to be increased for more complex scenarios (mushroom shaped tumors, tumors close to the optic nerve, oblique muscle related tilt, etc.) than the simple dome-shaped tumor examined and should be chosen on a case-by-case basis. The sources of uncertainty contributing most significantly to the total dosimetric uncertainty are seed placement within the plaques, treatment planning calculations, tumor height measurement, and plaque tilt. This work presents an uncertainty-based, rational approach to estimating an appropriate apex margin.

60 APPLIED LIFE SCIENCES↗

Effect of relative humidity on the composition of secondary organic aerosol from the oxidation of toluene

The effect of relative humidity (RH) on the chemical composition of secondary organic aerosol (SOA) formed from low-NO x toluene oxidation in the absence of seed particles was investigated. SOA samples were prepared in an aerosol smog chamber at < 2 % RH and 75 % RH, collected on Teflon filters, and analyzed with nanospray desorption electrospray ionization high-resolution mass spectrometry (nano-DESI–HRMS). Measurements revealed a significant reduction in the fraction of oligomers present in the SOA generated at 75 % RH compared to SOA generated under dry conditions. In a separate set of experiments, the particle mass concentrations were measured with a scanning mobility particle sizer (SMPS) at RHs ranging from < 2 to 90 %. It was found that the particle mass loading decreased by nearly an order of magnitude when RH increased from < 2 to 75–90 % for low-NO x toluene SOA. The volatility distributions of the SOA compounds, estimated from the distribution of molecular formulas using the “molecular corridor” approach, confirmed that low-NO x toluene SOA became more volatile on average under high-RH conditions. In contrast, the effect of RH on SOA mass loading was found to be much smaller for high-NO x toluene SOA. The observed increase in the oligomer fraction and particle mass loading under dry conditions were attributed to the enhancement of condensation reactions, which produce water and oligomers from smaller compounds in low-NO x toluene SOA. The reduction in the fraction of oligomeric compounds under humid conditions is predicted to partly counteract the previously observed enhancement in the toluene SOA yield driven by the aerosol liquid water chemistry in deliquesced inorganic seed particles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗