Search NASA⌕ Search

SEARCH · Search NASA

Results for “model reference control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

The Role of Numerical Simulation in the Design of Stimulation and Circulation Experiments for the EGS Collab Project

The United States Department of Energy, Geothermal Technologies Office (GTO) is funding a collaborative investigation of enhanced geothermal systems (EGS) processes at the meso-scale. This study, referred to as the EGS Collab project, is a unique opportunity for scientists and engineers to investigate the creation of fracture networks and circulation of fluids across those networks under in-situ stress conditions. The EGS Collab project is envisioned to comprise three experiments and the site for the first experiment is on the 4850 Level in phyllite of the Precambrian Poorman formation, at the Sanford Underground Research Facility, located at the former Homestake Gold Mine, in Lead, South Dakota. Principal objectives of the project are to develop a number of intermediate-scale field sites and to conduct well-controlled in situ experiments focused on rock fracture behavior and permeability enhancement. Data generated during these experiments will be compared against predictions of a suite of computer codes specifically designed to solve problems involving coupled thermal, hydrological, geomechanical, and geochemical processes. Comparisons between experimental and numerical simulation results will provide code developers with direction for improvements and verification of process models, build confidence in the suite of available numerical tools, and ultimately identify critical future development needs for the geothermal modeling community. Moreover, conducting thorough comparisons of models, modelling approaches, measurement approaches and measured data, via the EGS Collab project, will serve to identify techniques that are most likely to succeed at the Frontier Observatory for Research in Geothermal Energy (FORGE), the GTO’s flagship EGS research effort. As noted, outcomes from the EGS Collab project experiments will serve as benchmarks for computer code verification, but numerical simulation additional plays an essential role in designing these meso-scale experiments. This paper describes specific calculations and numerical simulation approaches conducted in support of the designs for the stimulation and circulation experiments, and their monitoring, including those for predicting seismic energies during stimulation, stimulation pressure requirements, impacts of borehole orientation on fracture development and trajectories, influence of notch shapes on hydraulic fracture initiation, and pressure limits on fluid circulation to avoid fracture growth.

Numerical Simulation, EGS Collab, EGS, Sanford Und↗

Dynamic QTL mapping for plant height in the hybrid population of Agropyron Gaertn.

Abstract Plant height (PH) plays a very important role for plant breeding and also serves as a model trait to dynamic development study. The dynamic quantitative trait locus (QTL) analysis for PH of Agropyron Gaertn. was carried out in a cross‐pollination (CP) hybrid population of A. Gaertn. based on the phenotypic data of PH at different developmental stages in four year‐sites and the constructed single‐nucleotide polymorphism (SNP) genetic map. The results showed that 69 QTL and nine major QTL were detected by unconditional QTL mapping. A total of 107 QTL and 13 major QTL were found using conditional QTL mapping. Forty‐seven QTL were detected by two methods. Two unconditional QTL, Qph2‐5 and Qph3‐4, were expressed as major and stable QTL for PH. Four major stable conditional QTL for PH, cQph4‐1 , cQph4‐8, cQph6‐2 and cQph6‐7 , were detected. Two conditional PH QTL, cQph3‐5 and cQPh3‐7 , were identified in four environments over multiple stages. The gene/QTL controlling PH was expressed in a certain spatiotemporal manner. These results could also provide a reference for genetic and breeding research of related plant.

Che, Yonghe↗

Online Waste Library (OWL) and Waste Forms Characteristics Annual Report

This report represents completion of milestone deliverable M2SF-19SNO10309013 "Online Waste Library (OWL) and Waste Forms Characteristics Annual Report" that reports annual status on fiscal year (FY) 2019 activities for the work package SF-19SN01030901 and is due on August 2, 2019. The online waste library (OWL) has been designed to contain information regarding United States (U.S.) Department of Energy (DOE)-managed (as) high-level waste (DHLW), spent nuclear fuel (SNF), and other wastes that are likely candidates for deep geologic disposal, with links to the current supporting documents for the data (when possible; note that no classified or official-use-only (OUO) data are planned to be included in OWL). There may be up to several hundred different DOE-managed wastes that are likely to require deep geologic disposal. This annual report on FY2019 activities includes evaluations of waste form characteristics and waste form performance models, updates to the OWL development, and descriptions of the management processes for the OWL. Updates to the OWL include an updated user's guide, additions to the OWL database content for wastes and waste forms, results of the beta testing and changes implemented from it. Also added are descriptions of the management/control processes for the OWL development, version control, and archiving. These processes have been implemented as part of the full production release of OWL (i.e., OWL Version 1.0), which has been developed on, and will be hosted and managed on, Sandia National Laboratories (SNL) systems. The version control/update processes will be implemented for updates to the OWL in the future. Additionally, another process covering methods for interfacing with the DOE SNF Database (DOE 2007) at Idaho National Laboratory on the numerous entries for DOE-managed SNF (DSNF) has been pushed forward by defining data exchanges and is planned to be implemented sometime in FY2020. The INL database is also sometimes referred to as the Spent Fuel Database or the SFDB, which is the acronym that will be used in this report. Once fully implemented, this integration effort will serve as a template for interfacing with additional databases throughout the DOE complex.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cleaning Up Large Groundwater Plumes to Drinking Water Standards: Dynamic Groundwater Recirculation at Reese Air Force Base - 17248

Overall cleanup of large plumes is perceived as being impossible because of issues of scale, contaminant mass accessibility, time to achieve cleanup, and cost. As a result, when a groundwater pump and treat (P and T) remedy is applied to larger plumes, the focus is usually hydraulic containment of contaminated groundwater to prevent further plume migration, rather than a total restoration objective. Recent experience with dynamic operation of groundwater extraction, treatment, and strategic reinjection (collectively referred to as dynamic groundwater recirculation [DGR]) demonstrates that large plume remediation can be accomplished cost effectively and in a timely manner. The insight from operating DGR remedies at multiple sites has demonstrated that contaminant mass residing in a complex aquifer setting is most appropriately described by a three-compartment model, which is a new revelation in contaminant hydrogeology redefining what is possible in restoration. A large-scale application of DGR was implemented under a firm fixed price contract at former Reese Air Force Base (AFB) located in Lubbock, Texas. The strategy was successful in restoration of a sole-source drinking water aquifer affected by a 3-mile long trichloroethene (TCE) plume. DGR allowed groundwater P and T rates to be decreased from over 3,400 liters per minute (lpm) to less than 1,500 lpm through initial optimization efforts. The DGR strategy focused extraction and reinjection on two key objectives: 1) maximizing contaminant mass recovery and 2) maintaining hydraulic control of the plume. Extraction and injection wells were dynamically operated and cycled to maintain a remediation pace that restored 0.8 to 1.2 hectares of the plume per week over a 6-year period. Plume cleanup to drinking water standards was achieved in 9 years of optimized operation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

PID-Regulated Heating System for PIP-II Reference Line

The Proton Improvement Project-2 centers on building a new superconducting linear particle accelerator (Linac) at Fermilab. At the heart of the accelerator is the reference line, a critical system that defines the ideal path for the particle beam as it passes through magnets, RF cavities, and other beamline elements. Temperature stability is crucial for the reliable operation of RF components, such as mixers and filters. Fluctuations affect key performance parameters like conversion loss, isolation, and linearity. To mitigate any drift caused by ambient temperature changes, a heating plate assembly is utilized to maintain key components at a controlled temperature of 40°C. The system utilizes an aluminum 36”x36”x0.5” heat plate powered by a MOSFET-based control circuit, delivering approximately 460 W of thermal energy through a resistor array. Real-time temperature feedback is provided by a PT100 Resistance Temperature Detector (RTD), which interfaces with a Proportional–Integral–Derivative (PID) control algorithm to maintain closed-loop temperature regulation. The control signal actively modulates the gate voltage of an N channel MOSFET, dynamically adjusting power delivery in response to deviations from the temperature setpoint. Simulations and LTspice models validate the functionality and responsiveness of the circuit under varying conditions. The prototype has successfully demonstrated stable thermal control, paving the way for integration into the PIP-II infrastructure. The final design will feature an expanded resistor array, as well as communication with a PLC for continuous data acquisition and diagnostics. This work directly supports Fermilab’s broader mission by contributing to the stability and reliability of core accelerator systems, enhancing the precision of particle beam delivery for future physics experiments.

Mosher, Alexander [Fermilab]↗

Synthesis and study of Pd-Rh alloy nanoparticles and alumina-supported low-content Pd-Rh catalysts for CO oxidation

Highlights: • A bimetallic Pd-Rh/alumina catalyst was prepared using coordination compound. • The peculiarities of precursor decomposition under different media were studied. • Catalytic performance and stability were examined in a CO oxidation reaction. - Abstract: Palladium and rhodium are known to be partly miscible metals. In present work, the peculiarities of coordination compound [Pd(NH{sub 3}){sub 4}]{sub 3}[Rh(NO{sub 2}){sub 6}]{sub 2} decomposition with formation of nanosized solid solutions under different atmospheres were studied by means of thermal gravimetry. Formation of alloy nanoparticles were confirmed by powder X-ray diffraction analysis, scanning and transmission electron microscopies. A bimetallic Pd-Rh/alumina catalyst was prepared by incipient wetness impregnation using coordination compound [Pd(NH{sub 3}){sub 4}]{sub 3}[Rh(NO{sub 2}){sub 6}]{sub 2} as a precursor. Monometallic reference samples were obtained using [Pd(NH{sub 3}){sub 4}](NO{sub 3}){sub 2} and Na{sub 3}[Rh(NO{sub 2}){sub 6}], correspondingly. Catalytic performance and stability of the catalysts were examined in a model reaction of CO oxidation in a prompt thermal aging regime. The environment of precursor decomposition was shown to affect noticeably both the initial activity and stability of the samples in the studied reaction. Reductive atmosphere in comparison with inert and oxidative ones facilitates the formation of the smallest active component species, which demonstrate highest initial activity but worst stability.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

FEASIBILITY STUDY REPORT FOR THE 200-ZP-1 GROUNDWATER OPERABLE UNIT

The Hanford Site, managed by the U.S. Department of Energy (DOE), encompasses approximately 1,517 km{sup 2} (586 mi{sup 2}) in the Columbia Basin of south-central Washington State. In 1989, the U.S. Environmental Protection Agency (EPA) placed the 100, 200, 300, and 1100 Areas of the Hanford Site on the 40 Code of Federal Regulations (CFR) 300, 'National Oil and Hazardous Substances Pollution Contingency Plan' National Contingency Plan [NCPD], Appendix B, 'National Priorities List' (NPL), pursuant to the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). The 200 Areas NPL sites consist of the 200 West and 200 East Areas (Figure 1-1). The 200 Areas contain waste management facilities, inactive irradiated fuel reprocessing facilities, and the 200 North Area (formerly used for interim storage and staging of irradiated fuel). Several waste sites in the 600 Area, located near the 200 Areas, also are included in the 200 Areas NPL site. The 200 Areas NPL site is in a region referred to as the 'Central Plateau' and consists of approximately 700 waste sites, excluding sites assigned to the tank farm waste management areas (WMAs). The 200-ZP-1 Groundwater Operable Unit (OU) consists of the groundwater located under the northern portion of the 200 West Area. Waste sources that contributed to the 200-ZP-1 OU included cribs and trenches that received liquid and/or solid waste in the past from the Z Plant and T Plant aggregate areas, WMA-T, WMA-TX/TY, and the State-Approved Land Disposal Site (SALDS). This feasibility study (FS) for the 200-ZP-1 Groundwater OU was prepared in accordance with the requirements of CERCLA decision documents. These decision documents are part of the Administrative Record for the selection of remedial actions for each waste site and present the selected remedial actions that are chosen in accordance with CERCLA, as amended by the Superfund Amendments and Reauthorization Act of 1986, and to the extent practicable, the NCP. This FS conforms to the conditions set forth in the Hanford Federal Facility Agreement and Consent Order (Tri-Party Agreement) (Ecology et al. 2003) and amendments, signed by the Washington State Department of Ecology (Ecology), EPA, and DOE Richland Operations Office (RL). This also includes Tri-Party Agreement Milestone M-015-00C for completing all 200 Area non-tank farm OU pre-Record of Decision (ROD) documents on or before December 31, 2011. This FS supports the final remedy selection for the 200-ZP-1 OU, as described in the Remedial Investigation/Feasibility Study Work Plan for the 200-ZP-1 Groundwater Operable Unit (referred to as the 200-ZP-1 RI/FS work plan) (DOE/RL-2003-55), as agreed upon by RL and EPA. Tri-Party Agreement Milestone M-015-48B required Draft A of the 200-ZP-1 OU FS and proposed plan to be transmitted to EPA by September 30, 2007. As agreed to with EPA in the 200 Area Unit Managers Meeting Groundwater Operable Unit Status (FH-0503130), the baseline risk assessment (BRA) was delayed from inclusion in the remedial investigation (RI) report and is completed and documented in this FS. The Remedial Investigation Report for 200-ZP-1 Groundwater Operable Unit (referred to as the 200-ZP-1 RI report) (DOE/RL-2006-24) included an evaluation of human health and ecological risks and hazards. The RI report identified the radiological and chemical contaminants of potential concern (COPCs) that represent the primary risks to human health and the environment. The complete risk assessment in this FS incorporates additional analytical data from the unconfined aquifer that were obtained during or after preparation of the RI report, particularly for carbon tetrachloride and technetium-99. This FS also includes the initial results from an ongoing study of technetium-99 contamination near WMA-T, the sampling of new wells near the 216-W-LC laundry waste crib and T Plant, updated Hanford vadose zone fate and transport modeling, and groundwater particle-tracking analysis. The purpose of this FS is to develop and evaluate alternatives for remediation of the groundwater in the 200-ZP-1 OU. The alternatives considered provide a range of potential response actions (i.e., no action; institutional controls and monitored natural attenuation [MNA]; and pump-and-treat with MNA, flow-path control, and institutional controls) that are appropriate to address site-specific conditions. The alternatives are evaluated against seven of the nine CERCLA evaluation criteria defined in Guidance for Conducting Remedial Investigations and Feasibility Studies Under CERCLA (EPA/540/G-891004). The remaining two CERCLA criteria will be formally assessed during the public comment period. The FS evaluation serves as the basis for identifying a remedy to mitigate potential risks to human health and the environment. A preferred alternative (or alternatives) will be presented to the public for review and comment in the proposed plan.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Theft of information in the take-grant protection model

Questions of information flow are in many ways more important than questions of access control, because the goal of many security policies is to thwart the unauthorized release of information, not merely the illicit obtaining of access rights to that information. The Take-Grant Protection Model is a theoretical tool for examining such issues because conditions necessary and sufficient for information to flow between two objects, and for rights to objects to be obtained or stolen, are known. These results are extended by examining the question of information flow from an object the owner of which is unwilling to release that information. Necessary and sufficient conditions for such theft of information to occur are derived, and bounds on the number of subjects that must take action for the theft to occur are presented. To emphasize the usefulness of these results, the security policies of complete isolation, transfer of rights with the cooperation of an owner, and transfer of information (but not rights) with the cooperation of the owner are presented; the last is used to model a simple reference monitor guarding a resource.

Bishop, Matt↗

CTAS: Computer intelligence for air traffic control in the terminal area

A system for the automated management and control of arrival traffic, referred to as the Center-TRACON Automation System (CTAS), has been designed by the ATC research group at NASA Ames research center. In a cooperative program, NASA and the FAA have efforts underway to install and evaluate the system at the Denver and Dallas/Ft. Worth airports. CTAS consists of three types of integrated tools that provide computer-generated intelligence for both Center and TRACON controllers to guide them in managing and controlling arrival traffic efficiently. One tool, the Traffic Management Advisor (TMA), establishes optimized landing sequences and landing times for aircraft arriving in the center airspace several hundred miles from the airport. In TRACON, TMA frequencies missed approach aircraft and unanticipated arrivals. Another tool, the Descent Advisor (DA), generates clearances for the center controllers handling at crossing times provided by TMA. In the TRACON, the final approach spacing tool (FAST) provides heading and speed clearances that produce and accurately spaced flow of aircraft on the final approach course. A data base consisting of aircraft performance models, airline preferred operational procedures and real time wind measurements contribute to the effective operation of CTAS. Extensive simulator evaluations of CTAS have demonstrated controller acceptance, delay reductions, and fuel savings.

Erzberger, Heinz↗

Disaster Response and Preparedness Application: Emergency Environmental Response Tool (EERT)

In 2000, the National Aeronautics and Space Administration (NASA) Environmental Office at the John C. Stennis Space Center (SSC) developed an Environmental Geographic Information Systems (EGIS) database. NASA had previously developed a GIS database at SSC to assist in the NASA Environmental Office's management of the Center. This GIS became the basis for the NASA-wide EGIS project, which was proposed after the applicability of the SSC database was demonstrated. Since its completion, the SSC EGIS has aided the Environmental Office with noise pollution modeling, land cover assessment, wetlands delineation, environmental hazards mapping, and critical habitat delineation for protected species. At SSC, facility management and safety officers are responsible for ensuring the physical security of the facilities, staff, and equipment as well as for responding to environmental emergencies, such as accidental releases of hazardous materials. All phases of emergency management (planning, mitigation, preparedness, and response) depend on data reliability and system interoperability from a variety of sources to determine the size and scope of the emergency operation. Because geospatial data are now available for all NASA facilities, it was suggested that this data could be incorporated into a computerized management information program to assist facility managers. The idea was that the information system could improve both the effectiveness and the efficiency of managing and controlling actions associated with disaster, homeland security, and other activities. It was decided to use SSC as a pilot site to demonstrate the efficacy of having a baseline, computerized management information system that ultimately was referred to as the Emergency Environmental Response Tool (EERT).

Smoot, James↗

Comparing NASA and ESA Cost Estimating Methods for Human Missions to Mars

To compare working methodologies between the cost engineering functions in NASA Marshall Space Flight Center (MSFC) and ESA European Space Research and Technology Centre (ESTEC), as well as to set-up cost engineering capabilities for future manned Mars projects and other studies which involve similar subsystem technologies in MSFC and ESTEC, a demonstration cost estimate exercise was organized. This exercise was a direct way of enhancing not only cooperation between agencies but also both agencies commitment to credible cost analyses. Cost engineers in MSFC and ESTEC independently prepared life-cycle cost estimates for a reference human Mars project and subsequently compared the results and estimate methods in detail. As a non-sensitive, public domain reference case for human Mars projects, the Mars Direct concept was chosen. In this paper the results of the exercise are shown; the differences and similarities in estimate methodologies, philosophies, and databases between MSFC and ESTEC, as well as the estimate results for the Mars Direct concept. The most significant differences are explained and possible estimate improvements identified. In addition, the Mars Direct plan and the extensive cost breakdown structure jointly set-up by MSFC and ESTEC for this concept are presented. It was found that NASA applied estimate models mainly based on historic Apollo and Space Shuttle cost data, taking into account the changes in technology since then. ESA used models mostly based on European satellite and launcher cost data, taking into account the higher equipment and testing standards for human space flight. Most of NASA's and ESA s estimates for the Mars Direct case are comparable, but there are some important, consistent differences in the estimates for: 1) Large Structures and Thermal Control subsystems; 2) System Level Management, Engineering, Product Assurance and Assembly, Integration and Test/Verification activities; 3) Mission Control; 4) Space Agency Program Level activities.

Hunt, Charles D.↗

Insights on fuel performance in advanced compression ignition engines: combining engine thermodynamic trajectory and fuel ignition delay iso-contour

With the development of various low temperature engine combustion strategies, the behavior of gasoline-type fuels under compression ignition conditions has attracted extensive research interest. In this study, gasoline surrogates based on toluene primary reference fuel blends (TPRF) with different research and motor octane numbers (i.e., RON and MON) and fuel octane sensitivity (OS) have been strategically designed using a recently established surrogate model, and their combustion chemistry is further described using a well-validated kinetic mechanism. Based on a typical advanced compression ignition engine configuration, the crank angle corresponding to 50% total heat release (CA50) was utilized as an indicator of the overall fuel reactivity, and representative engine operating conditions have been selected based on the regime exhibited from the CA50 iso-contours. By combining the thermodynamic trajectory and ignition delay isocontours, useful insights on the fuel reactivity and sensitivity have been obtained to evaluate the fuel performance under various engine operating regimes with distinct chemistry, accounting for the effects of equivalence ratio and ratio of exhaust gas recirculation (EGR). This study provides useful insight on the different effects of engine operating conditions on a fuel’s performance following different engine trajectories, based on the different controlling fuel chemistry.

Tao, Mingyuan↗

Controls Algorithms, Models, and Stability Assessments of the RCS and TVC systems on Mars Ascent Vehicle

This paper presents a control systems overview of the Mars Ascent Vehicle (MAV) control design and stability analysis with two separate control methods: Thrust Vector Control (TVC) based control using main engine thrust and Reaction Control System (RCS) via thrusters. A pole-placement TVC controller is proposed to address quickly peaking thrust produced by the MAV solid propulsion engine. The controllerutilizes real-time parameter estimation to calculate control gains using an online pole-placement method. The pole-placement technique allows the controller to maintain constant stability margins throughout the flight under changing parameters and rapidly peaking thrust. A mathematical stability proof via Lyapunov inequality and Nichols method is demonstrated to support the stability of the method. In addition to the TVC control, a phase-plane based RCS control logic is applied to the vehicle for roll control during ascent and all axes during coast phases of flight. The logic implemented is an on-off type logic that applies pre-determined thrusters firings in reference to boundary parameters of pointing and rate error chosen to balance desired pointing with stability. A describing function methodology is applied to the non-linear phase plane loop response to determine linear stability across all flight phases. The controller additionally applies command alteration logic to output signals to account for RCS hardware limitations. The following paper will provide the methodology for controller implementation of the TVC and RCS, and provide a summary of results of the MAV performance applying the aforementioned control design.

Han Woong Bae↗

Characterization of the arc in crossflow using a two-temperature nonequilibrium plasma flow model

Diverse industrial applications such as circuit breakers and wire arc spraying involve the interaction between an electric arc and a stream of gas impinging perpendicular to it, a configuration commonly referred to as the arc in crossflow. The arc in crossflow is simulated using a three-dimensional time-dependent two-temperature (heavy-species and electrons) plasma flow model to better capture plasma-gas interactions and deviations from Local Thermodynamic Equilibrium (LTE). The coupled fluid-electromagnetic flow model is solved in a monolithic manner using Variational Multiscale Finite Element Method. Simulation findings are validated with experimental findings and contrasted against results obtained with a LTE model. Results from the two-temperature model corroborate experimental observations while providing quantification of the deviation between heavy-species and electron temperatures. The model is used to characterize the arc in crossflow as a function of the Reynolds and Enthalpy dimensionless numbers, which encapsulate the inter-dependence among the main parameters total current, inflow velocity, and inter-electrode spacing. Furthermore, the characterization revealed the behavior of arc shape, voltage drop, arc power, the degree of nonequilibrium, as well as the characteristic plasma front thickness, with varying controlling parameters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Numerical Stiffness based Simulation of Mixed Transmission Systems

Inclusion of power electronics allows increased controllability and stability in power systems. The simulation of such systems on a large-scale is challenging due to the presence of a large number of switches and nonlinear devices. This paper presents an advanced simulation algorithm to solve the aforementioned problem. The algorithm considers separation of differential algebraic equations (DAEs) on the basis of numerical stiffness and applies hybrid discretization algorithms to simulate the DAEs. The DAEs, in this paper, represent the nonlinear nonautonomous switched system dynamics of power systems. Stability analysis is performed on a general class of nonlinear nonautonomous switched systems to show the constraints under which the proposed algorithm is stable. To show the validity of the proposed algorithm, two case studies are considered: single high-voltage direct current (HVdc) substation based on the modular multilevel converter (MMC); and an example three-terminal MMC-HVdc system. Furthermore, relaxation techniques are introduced to create a stable interface for the separated DAEs. The developed algorithms are also validated with PSCAD/EMTDC-detailed reference models.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Flight evaluation of differential GPS aided inertial navigation systems

Algorithms are described for integration of Differential Global Positioning System (DGPS) data with Inertial Navigation System (INS) data to provide an integrated DGPS/INS navigation system. The objective is to establish the benefits that can be achieved through various levels of integration of DGPS with INS for precision navigation. An eight state Kalman filter integration was implemented in real-time on a twin turbo-prop transport aircraft to evaluate system performance during terminal approach and landing operations. A fully integrated DGPS/INS system is also presented which models accelerometer and rate-gyro measurement errors plus position, velocity, and attitude errors. The fully integrated system was implemented off-line using range-domain (seventeen-state) and position domain (fifteen-state) Kalman filters. Both filter integration approaches were evaluated using data collected during the flight test. Flight-test data consisted of measurements from a 5 channel Precision Code GPS receiver, a strap-down Inertial Navigation Unit (INU), and GPS satellite differential range corrections from a ground reference station. The aircraft was laser tracked to determine its true position. Results indicate that there is no significant improvement in positioning accuracy with the higher levels of DGPS/INS integration. All three systems provided high-frequency (e.g., 20 Hz) estimates of position and velocity. The fully integrated system provided estimates of inertial sensor errors which may be used to improve INS navigation accuracy should GPS become unavailable, and improved estimates of acceleration, attitude, and body rates which can be used for guidance and control. Precision Code DGPS/INS positioning accuracy (root-mean-square) was 1.0 m cross-track and 3.0 m vertical. (This AGARDograph was sponsored by the Guidance and Control Panel.)

Mcnally, B. David↗

Comparison of Different Fractionation Schedules Toward a Single Fraction in High-Dose-Rate Brachytherapy as Monotherapy for Low-Risk Prostate Cancer Using 3-Dimensional Radiobiological Models

Purpose: The aim of the present study was the investigation of different fractionation schemes to estimate their clinical impact. For this purpose, widely applied radiobiological models and dosimetric measures were used to associate their results with clinical findings. Methods and Materials: The dose distributions of 12 clinical high-dose-rate brachytherapy implants for prostate were evaluated in relation to different fractionation schemes. The fractionation schemes compared were: (1) 1 fraction of 20 Gy; (2) 2 fractions of 14 Gy; (3) 3 fractions of 11 Gy; and (4) 4 fractions of 9.5 Gy. The clinical effectiveness of the different fractionation schemes was estimated through the complication-free tumor control probability (P{sub +}), the biologically effective uniform dose, and the generalized equivalent uniform dose index. Results: For the different fractionation schemes, the tumor control probabilities were 98.5% in 1 × 20 Gy, 98.6% in 2 × 14 Gy, 97.5% in 3 × 11 Gy, and 97.8% in 4 × 9.5 Gy. The corresponding P{sub +} values were 88.8% in 1 × 20 Gy, 83.9% in 2 × 14 Gy, 86.0% in 3 × 11 Gy, and 82.3% in 4 × 9.5 Gy. With use of the fractionation scheme 4 × 9.5 Gy as reference, the isoeffective schemes regarding tumor control for 1, 2, and 3 fractions were 1 × 19.68 Gy, 2 × 13.75 Gy, and 3 × 11.05 Gy. The optimum fractionation schemes for 1, 2, 3, and 4 fractions were 1 × 19.16 Gy with a P{sub +} of 91.8%, 2 × 13.2 Gy with a P{sub +} of 89.6%, 3 × 10.6 Gy with a P{sub +} of 88.4%, and 4 × 9.02 Gy with a P{sub +} of 86.9%. Conclusions: Among the fractionation schemes 1 × 20 Gy, 2 × 14 Gy, 3 × 11 Gy, and 4 × 9.5 Gy, the first scheme was more effective in terms of P{sub +}. After performance of a radiobiological optimization, it was shown that a single fraction of 19.2 to 19.7 Gy (average 19.5 Gy) should produce at least the same benefit as that given by the 4 × 9.5 Gy scheme, and it should reduce the expected total complication probability by approximately 40% to 55%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Grid-Scale Ternary-Pumped Thermal Electricity Storage for Flexible Operation of Nuclear Power Generation under High Penetration of Renewable Energy Sources

In this work, the integration of a grid-scale ternary-Pumped Thermal Electricity Storage (t-PTES) with a nuclear power generation to enhance operation flexibility is assessed using physics-based models and digital real time simulation. A part of the electricity from the nuclear power generation is delivered to the grid, and the balance is used to power a heat pump that can be augmented by an auxiliary resistive load element to increase the charging rate of the thermal storage. This increases the thermal potential between hot and cold thermal stores (usually solid materials or molten salts inside large storage tanks). The thermal energy is transformed back into electricity by reversing the heat pump cycle. Different transient scenarios including startup, shutdown, and power change for grid-connected operation are simulated to determine the behavior of the hybrid nuclear-t-PTES system operating under variable loads that constitute a departure from conventional, baseload nuclear plant operation schemes. Ternary refers to the three modes operation: (i) heat pump (including heating coil), (ii) heat engine, and (iii) simultaneous operation of heat pump (including heating coil) and heat engine during changeover from pumping to generation or vice-versa. The controllability of t-PTES in the short timescales as a dynamic load is used to demonstrate operational flexibility of hybrid nuclear plants for flexible operation through advanced load management. The integration of t-PTES into nuclear power systems enhances the system flexibility and is an enabler for high penetration of renewable energy resources.

24 POWER TRANSMISSION AND DISTRIBUTION↗