Search NASA⌕ Search

SEARCH · Search NASA

Results for “module performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Performance of Different Water-Based Binder Formulations for Ni-Rich Cathodes Evaluated in LiNi 0.8 Mn 0.1 Co 0.1 O 2 //Graphite Pouch Cells

Water-based processing for lithium-ion battery electrodes is attractive due to its lower manufacturing cost and smaller environmental impact. However, multiple challenges associated with aqueous cathode processing have hindered commercial adoption. Polymer binders are an important component of the electrode, and thus the choice of binders can alter electrode cycling performance significantly. In this work, four different water-based binder combinations are investigated for Ni-rich LiNi 0.8 Mn 0.1 Co 0.1 O 2 (NMC811)-based cathodes, with a focus on the long-term electrochemical performance in practical-format full pouch cells. No additional pH-modulating additives were added to the aqueous cathode slurries, and no protective coatings were present on the cathode or aluminum current collector. Results are compared with the standard PVDF/NMP-based binder/solvent combination, used as a baseline. The influence of water-based binder type on slurry rheology and electrode microstructure are also discussed. All cells made by water-processing had worse rate performance compared to the baseline. However, the cell discharge capacity after 1000 U.S. Advanced Battery Consortium (USABC) cycles at C/3 charge/discharge rate was comparable to the baseline for two of the water-based cathode formulations (CMC & JSR, and LiPAA), demonstrating the potential viability of aqueous-processed Ni-rich cathodes at a commercial scale.

25 ENERGY STORAGE↗

BatteryPro: A Python Toolkit for Battery Data Analysis and Machine Learning Predictions

Analyzing battery test data for research & development can be time-consuming since battery tests often run on the order of months to years, generating large volumes of data. BatteryPro is a comprehensive Python package and software designed to facilitate advanced analysis and performance predictions for battery test data. Developed for battery researchers, it supports data types from widely used battery testing instruments, including MACCOR and Biologic cycling systems. The software provides a variety of tools for extracting and plotting key battery parameters such as time, voltage, capacity, current, and pressure. In addition to its extensive data analysis capabilities, BatteryPro features a dedicated machine learning module that employs a Bayesian Gaussian Mixture Model (GMM) to predict battery performance and degradation. Users can generate synthetic capacity fade data, calculate fade metrics, and leverage predictive models to forecast long-term battery behavior. The software's graphical user interface (GUI) enhances usability, allowing researchers to upload, merge, and analyze multiple data files with full customizability. The GUI also supports machine learning predictions, enabling users to fit models and make predictions based on selected data and parameters. BatteryPro is built using QtDesigner, scikit-learn, matplotlib, and pandas, ensuring a high level of customization, flexibility, and accuracy in battery data analysis. This tool aims to empower researchers with the ability to perform detailed battery analysis and make informed predictions, ultimately advancing the field of battery research.

25 - ENERGY STORAGE↗

Scale-up Testing of Advanced Polaris Membrane in CO2 Capture Technology

This final technical report describes work conducted by Membrane Technology and Research, Inc. (MTR) for the U.S. Department of Energy (DOE), National Energy Technology Lab (NETL) on the scale-up and testing of advanced Polaris™ membrane CO2 capture technology at the Technology Centre Mongstad (TCM) under award number DE-FE0031591. The work was performed from August 1, 2018 through January 31, 2023. The overall goal of this project was to design, build and operate an advanced Polaris membrane CO2 capture system at TCM. MTR was assisted in this project by Trimeric Corporation (Trimeric), an engineering design services company, the Carbon Capture Simulation for Industry Impact (CCSI2), a partnership among national laboratories, industry, and academic institutions, and the Technology Centre Mongstad (TCM), who provided the host site for the slipstream field test. This report details the work conducted to scale-up MTR’s second-generation (Gen-2) Polaris membrane and advanced planar membrane modules to a final form factor optimized for commercial use; validate their performance in an engineering-scale field test at TCM; and to show the potential of the MTR process to meet DOE CO2 capture targets from large source point emitters. Work for this project included membrane optimization and scale-up, advanced planar module design and fabrication, design and fabrication of an engineering-scale field test membrane skid, operation of the field test skid processing Residue Fluid Catalytic Cracker (RFCC) industrial flue gas at TCM, and a detailed techno-economic analysis (TEA) of the MTR membrane post-combustion process for CO2 capture. This project validated recent membrane technology advancements at the engineering-scale, moves the MTR advanced post-combustion capture technology to TRL-6, and mitigates risk in future Large Pilot or Demonstration scale-up activities.

20 FOSSIL-FUELED POWER PLANTS↗

Quantifying optical loss of high-voltage degradation modes in photovoltaic modules using spectral analysis

The direct current bias for photovoltaic (PV) modules interconnected in series-strings may include both high voltage negative (“HV-”) and positive (“HV+”) polarity with respect to the electrical ground. Multiple degradation modes, resulting in quantifiable optical loss, were found to occur during HV-/HV+ sequential stress, including corrosion of the external glass surface, encapsulant delamination (at its interfaces with the glass and the PV cell), internal haze formation (resulting from a chemical interaction between the glass and the encapsulant), corrosion and migration of the gridlines, and corrosion of the silicon nitride (Si x N y ) antireflective coating on the cell. The effects of these separate modes were examined using monolithic (e.g., glass or PV cell) and laminated-coupon (glass/encapsulant/glass or glass/encapsulant/cell/encapsulant/backsheet) specimens. Characterizations during and after unbiased accelerated testing at 85°C/85% relative humidity included spectrophotometry, optical microscopy, electron microscopy, and ellipsometry. For some module components (i.e., the glass and the Si x N y coating), the optical performance was determined through iterative analysis of empirical measurements. Concentrating on just their spectral effect, a novel model was then developed to estimate the transfer of light to the PV cell and the return of light from the PV module with simultaneous degradation mechanisms, which was compared with a mini-module previously subjected to HV-/HV+ stress. Here the model suggests that one third of the current loss observed for the mini-module can be attributed to the optical degradation of the packaging materials. The dominant degradation modes include encapsulant delamination and corrosion of the Si x N y coating. Recommendations are given so that the optical model may be improved relative to accelerated testing and validated relative to field aging.

14 SOLAR ENERGY↗

Performance of an X-ray single pixel TES microcalorimeter under DC and AC biasing

We are developing Frequency Domain Multiplexing (FDM) for the read-out of TES imaging microcalorimeter arrays for future X-ray missions like IXO. In the FDM configuration the TES is AC voltage biased at a well defined frequencies (between 0.3 to 10 MHz) and acts as an AM modulating element. In this paper we will present a full comparison of the performance of a TES microcalorimeter under DC bias and AC bias at a frequency of 370 kHz. In both cases we measured the current-to-voltage characteristics, the complex impedance, the noise, the X-ray responsivity, and energy resolution. The behaviour is very similar in both cases, but deviations in performances are observed for detector working points low in the superconducting transition (R/R{sub N}<0.5). The measured energy resolution at 5.89 keV is 2.7 eV for DC bias and 3.7 eV for AC bias, while the baseline resolution is 2.8 eV and 3.3 eV, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Best Practices for Measuring the Modulation Transfer Function of Video Endoscopes

Endoscopes are crucial for assisting in surgery and disease diagnosis, including the early detection of cancer. The effective use of endoscopes relies on their optical performance, which can be characterized with a series of metrics such as resolution, vital for revealing anatomical details. The modulation transfer function (MTF) is a key metric for evaluating endoscope resolution. However, the 2020 version of the ISO 8600-5 standard, while introducing an endoscope MTF measurement method, lacks empirical validation and excludes opto-electronic video endoscopes, the largest family of endoscopes. Measuring the MTF of video endoscopes requires tailored standards that address their unique characteristics. This paper aims to expand the scope of ISO 8600-5:2020 to include video endoscopes, by optimizing the MTF test method and addressing parameters affecting measurement accuracy. We studied the effects of intensity and uniformity of image luminance, chart modulation compensation, linearity of image digital values, auto gain control, image enhancement, image compression and the region of interest dimensions on images of slanted-edge test charts, and thus the MTF based on these images. By analyzing these effects, we provided recommendations for setting and controlling these factors to obtain accurate MTF curves. Our goal is to enhance the standard’s relevance and effectiveness for measuring the MTF of a broader range of endoscopic devices, with potential applications in the MTF measurement of other digital imaging devices.

47 OTHER INSTRUMENTATION↗

Simulation information regarding Sandia National Laboratories trinity capability improvement metric.

Sandia National Laboratories, Los Alamos National Laboratory, and Lawrence Livermore National Laboratory each selected a representative simulation code to be used as a performance benchmark for the Trinity Capability Improvement Metric. Sandia selected SIERRA Low Mach Module: Nalu, which is a uid dynamics code that solves many variable-density, acoustically incompressible problems of interest spanning from laminar to turbulent ow regimes, since it is fairly representative of implicit codes that have been developed under ASC. The simulations for this metric were performed on the Cielo Cray XE6 platform during dedicated application time and the chosen case utilized 131,072 Cielo cores to perform a canonical turbulent open jet simulation within an approximately 9-billion-elementunstructured- hexahedral computational mesh. This report will document some of the results from these simulations as well as provide instructions to perform these simulations for comparison.

Agelastos, Anthony Michael↗

Effective Modulation of Interlayer Excitons in WSe 2 /WS 2 Heterostructures by Plasmon–Exciton Interaction

Effective charge transfer and carrier separation at the interface are paramount for optimizing the performance of devices based on van der Waals heterostructures. In this investigation, surface plasmons generated by gold nanoparticles are employed to modulate the photocarrier dynamics in WSe 2 /WS 2 heterostructures. The results of pump-probe measurements reveal that the efficiency of carrier transfer across the WSe 2 /WS 2 heterostructure interface can be significantly enhanced via energy transfer mechanisms mediated by gold plasmons. Moreover, the electric field engendered by the plasmonic oscillations can modulate the dipole moment of the interlayer exciton. These well-aligned excitons avoid the annihilation and the extension of the lifetime of the excitons with increased pump power is realized by screening effect. The findings presented herein offer valuable insights for the active manipulation of charge transfer and extend our understanding of the integral role played by plasmon-exciton coupling in mediating charge separation in van der Waals heterostructures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Module OT PNM Field Demonstration Test Procedure

This document will detail a field demonstration test procedure for the Module OT device developed for the joint NREL-SNL DOE CEDS project titled "Modular Security Apparatus for Managing Distributed Cryptography for Command & Control Messages on Operational Technology (OT) Networks." The aim of this document is to create the testing and evaluation procedure for field demonstration of the device; this includes primarily functional testing and implementation testing at Public Service Company of New Mexico's (PNM's) Prosperity solar site environment. Specifically, the Module OT devices will be integrated into the Prosperity solar site system; traffic will be encrypted between several points of interest at the site (e.g., inverter micrologger and switch). The tests described in this document will be performed to assess the impact and effectiveness of the encryption capabilities provided by the Module OT device.

97 MATHEMATICS AND COMPUTING↗

Computational flow modeling of triply periodic minimal surfaces as feed channel spacers in ultra-high pressure reverse osmosis applications

Triply periodic minimal surfaces (TPMS) are a special class of mathematical surfaces characterized by a high surface area-to-volume ratio. They have generated considerable interest in fields such as acoustics, heat transfer, and membrane-based filtration processes. This study evaluates the performance of four different TPMS designs—Schoen Gyroid, Schoen Crossed Layers of Parallels (CLP), Schoen Transverse Crossed Layers of Parallels (tCLP), and Schwarz-Primitive—when used as feed channel spacers under ultra-high pressure reverse osmosis (UHPRO) conditions, at approximately 200 bar. Our experimentally validated computational fluid dynamics model reveal different flow patterns within the feed channels for each of the four TPMS designs, leading to varying hydrodynamic and permeation properties. Under the simulated UHPRO conditions, the Gyroid and tCLP designs yield up to a 23% increase in average permeate velocity and a 14% reduction in average membrane-surface concentration relative to a non-woven spacer of the same porosity. Furthermore, the enhanced performance comes with an increased feed channel pressure drop, although it only constitutes less than 4% of the operating pressure when extrapolated for a meter-long membrane module. Additionally, the study analyzes the effects of varying inlet velocity and spacer porosity on membrane performance. Overall, this research provides valuable insights into the potential use of TPMS spacers in UHPRO applications.

36 MATERIALS SCIENCE↗

The DUNE Photon Detection System

DUNE is an underground neutrino oscillation experiment that will be performing precision measurements of the PMNS matrix to determine unambiguously the mass ordering and the leptonic CP violation. It also comprises a rich non-accelerator physics program for the detection of supernova neutrinos, nucleon decay, and BSM physics. DUNE employs a high-power neutrino beam under construction at Fermilab together with the DUNE Near Detector, and four liquid argon TPCs (Far Detector) that will be installed at the Sanford Underground Research Facility in South Dakota, 1300 km away from the neutrino source. The photon detection system (PDS) – which records the 128 nm scintillation light of argon and provides the time of interaction of the beam neutrinos in the Far Detector - is critical for studying nucleon decay and detecting Supernova Neutrino Bursts. The PDS also complements the calorimetric measurement performed by the TPC (i.e. the charge readout) and contributes to the energy calibration and time performance of the Far Detector. The article is an overview of the design of the PDS for the first DUNE far detector module, with special emphasis on VUV light trapping in a cryogenic environment, its technical challenges, and the expected physics performance. The status of the construction of the PDS and its validation in the Run II of ProtoDUNE-SP will be also presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Global Transformations for Legacy Parallel Applications via Structural Analysis and Rewriting

Performance and scalability optimization of large HPC applications is currently a labor-intensive, manual process with very low productivity. Major difficulties come from the disaggregated environment for HPC application development: the compiler is only involved in local decisions (core or multithreaded domain), while a library-based, communication-oriented programming model realizes whole-machine parallelism. Realizing any major global change in such a disaggregated environment is very difficult and involves changing large portions of the source code. We present semi-automated techniques, based on structural analysis and rewriting, for performing global transformations on an HPC application source code. We present two case studies using the Self-Consistent Field (SCF) standalone benchmark as well as the Coupled Cluster (CCSD) module (2.9 million lines of Fortran code), a key module of the NWChem computational chemistry application. We demonstrate how structural rewriting techniques can be used to automate transformations that affect multiple sections of the application's source code. We show that the transformations can be applied in a systematic fashion across the source code bases with minimal manual effort. These transformations improve the scalability of the SCF benchmark by more than two orders of magnitude and the performance of the full CCSD module by a factor of 4.0.

legacy parallel applications↗

Photoelectric-enhanced radiation therapy with quasi-monochromatic computed tomography

Photoelectric-enhanced radiation therapy is a bimodal therapy, consisting of the administration of highly radiation-absorbing substances into the tumor area and localized regional irradiation with orthovoltage x-rays. Irradiation can be performed by a modified computed tomography (CT) unit equipped with an additional x-ray optical module which converts the polychromatic, fan-shaped CT beam into a monochromatized and focused beam for energy-tuned photoelectric-enhanced radiotherapy. A dedicated x-ray optical module designed for spatial collimation, focusing, and monochromatization was mounted at the exit of the x-ray tube of a clinical CT unit. Spectrally resolved measurements of the resulting beam were performed using an energy-dispersive detection system calibrated by synchrotron radiation. The spatial photon fluence was determined by film dosimetry. Depth-dose measurements were performed and compared to the polychromatic CT and a therapeutic 6 MV beam. The spatial dose distribution in phantoms using a rotating radiation source (quasi-monochromatic CT and 6 MV, respectively) was investigated by gel dosimetry. The photoelectric dose enhancement for an iodine fraction of 1% in tissue was calculated and verified experimentally. The x-ray optical module selectively filters the energy of the tungsten K{alpha} emission line with an FWHM of 5 keV. The relative photon fluence distribution demonstrates the focusing characteristic of the x-ray optical module. A beam width of about 3 mm was determined at the isocenter of the CT gantry. The depth-dose measurements resulted in a half-depth value of approximately 36 mm for the CT beams (quasi-monochromatic, polychromatic) compared to 154 mm for the 6 MV beam. The rotation of the radiation source leads to a steep dose gradient at the center of rotation; the gel dosimetry yields an entrance-to-peak dose ratio of 1:10.8 for the quasi-monochromatic CT and 1:37.3 for a 6 MV beam of the same size. The photoelectric dose enhancement factor increases from 2.2 to 2.4 by using quasi-monochromatic instead of polychromatic radiation. An additional increase in the radiation dose by a factor of 1.4 due to the focusing characteristic of the x-ray optical module was calculated. Photoelectric-enhanced radiation therapy based on a clinical CT unit combined with an x-ray optical module is a novel therapy option in radiation oncology. The optimized quasi-monochromatic radiation is strongly focused and ensures high photoelectric dose enhancement for iodine.

61 RADIATION PROTECTION AND DOSIMETRY↗

III-V/Si Tandem Cell to Module Interconnection - Comparison Between Different Operation Modes

III-V/Si tandem solar cells have the potential to surpass the theoretical efficiency limit of silicon solar cells. On the cell level it was shown at this conference that three-terminal tandem (3T) devices consisting of III-V top and Si bottom cell perform as well as operating the subcells independently. However, integrating these 3T devices in a module requires voltage matching of the top and the bottom cell. Here we investigate the robustness of 3T III-V/Si tandem devices in comparison with independently operated and current matched two terminal devices with respect to spectral and thermal effects. Under most conditions, interconnected voltage matched devices are able to perform as well as those with independent operation of the top and bottom cell, and prove that 3T devices significantly outperform current matched devices.

14 SOLAR ENERGY↗

PV Fleet Performance Data Initiative Program and Methodology

The US Department of Energy’s PV Fleet Performance Data Initiative has been launched in order to collect and evaluate production data across multiple PV fleet partners. Performance statistics are anonymized, aggregated and shared to represent a snapshot of the US commercial and utility-scale fleet. Production data have been collected from over 1500 systems representing more than 1.3 GWdc capacity. Preliminary analysis indicates median performance loss rates are in line with previous publications of system degradation, on the order of –0.6%/yr to –0.9%/yr (preliminary numbers subject to change). These values are higher than module-only degradation rates which are often used in pro-forma estimates of project performance and economics, potentially exposing owner/operators to increased risk if systems under-perform over time.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Coherent cooling of atoms in a frequency-modulated standing laser wave: Wave function and stochastic trajectory approaches

The wave function of a moderately cold atom in a stationary near-resonant standing light wave delocalizes very fast due to wave packet splitting. However, we show that frequency modulation of the field can suppress packet splitting for some atoms whose specific velocities are in a narrow range. These atoms remain localized in a small space for a long time. We demonstrate and explain this effect numerically and analytically. We also demonstrate that the modulated field can not only trap but also cool the atoms. We perform a numerical experiment with a large atomic ensemble having wide initial velocity and energy distributions. During the experiment, most of atoms leave the wave while the trapped atoms have a narrow energy distribution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

10-Gb/s Distributed Amplifier-Based VCSEL Driver IC With ESD Protection in 130-nm CMOS

Here, this paper presents a low-power 10-Gb/s vertical cavity surface emitting laser (VCSEL) driver integrated circuit (IC) with electrostatic discharge (ESD) protection in the 130-nm CMOS technology. A distributed amplifier (DA)-based modulator is proposed to boost the driver bandwidth. It employs artificial transmission lines to cancel the device parasitic capacitances of the driver. A distributed ESD protection technique is applied to equalize the group delay of the DA to optimize the jitter performance. To minimize the silicon area, the optimal number of DA taps in the proposed modulator has been derived. To compensate for the capacitive load and the channel losses at the output of the driver, a frequency-domain preemphasis scheme is proposed. The proposed DA modulator occupies an area of 0.69 mm 2 , and the entire driver IC has a die size of 2 mm×2 mm, including the pads. Both electrical and optical tests have been carried out to characterize the performance of the proposed VCSEL driver IC. Measurements at a data rate of 10-Gb/s demonstrate a typical power consumption of 85 mW under a single 2.5 V supply voltage (49 mW, if separate 1.2 and 2.5 V supplies are used) and an rms jitter of 0.63 and 1.12 ps for the electrical test and optical test, respectively.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Program Final Report - Develop Thermoelectric Technology for Automotive Waste Heat Recovery

We conducted a vehicle analysis to assess the feasibility of thermoelectric technology for waste heat recovery and conversion to useful electrical power and found that eliminating the 500 W of electrical power generated by the alternator corresponded to about a 7% increase in fuel economy (FE) for a small car and about 6% for a full size truck. Electric power targets of 300 W were established for city and highway driving cycles for this project. We obtained critical vehicle level information for these driving cycles that enabled a high-level design and performance analysis of radiator and exhaust gas thermoelectric subsystems for several potential vehicle platforms, and we identified the location and geometric envelopes of the radiator and exhaust gas thermoelectric subsystems. Based on this analysis, we selected the Chevrolet Suburban as the most suitable demonstration vehicle for this project. Our modeling and thermal analysis assessment of a radiator-based thermoelectric generator (TEG), however, revealed severe practical limitations. Specifically the small temperature difference of 100°C or less between the engine coolant and ambient air results in a low Carnot conversion efficiency, and thermal resistance associated with air convection would reduce this conversion efficiency even further. We therefore decided not to pursue a radiator-based waste heat recovery system and focused only on the exhaust gas. Our overall approach was to combine science and engineering: (1) existing and newly developed TE materials were carefully selected and characterized by the material researcher members of our team, and most of the material property results were validated by our research partners, and (2) system engineers worked closely with vehicle engineers to ensure that accurate vehicle-level information was used for developing subsystem models and designs, and the subsystem output was analyzed for potential fuel economy gains. We incorporated material, module, subsystem, and integration costs into the material selection criteria in order to balance various materials, module and subsystem design, and vehicle integration options. Our work on advanced TE materials development and on TEG system design, assembly, vehicle integration, and testing proceeded in parallel efforts. Results from our two preliminary prototype TEGs using only Bi-Te TE modules allowed us to solve various mechanical challenges and to finalize and fine tune aspects of the design and implementation. Our materials research effort led us to quickly abandon work on PbTe and focus on the skutterudite materials due to their superior mechanical performance and suitability at automotive exhaust gas operating temperatures. We synthesized a sufficiently large quantity of skutterudite material for module fabrication for our third and final prototype. Our TEG#3 is the first of its kind to contain state-of-the-art skutterudite-based TE modules to be installed and tested on a production vehicle. The design, which consisted of 24 skutterudite modules and 18 Bi-Te modules, attempted to optimize electrical power generation by using these two kinds of TE modules that have their peak performance temperatures matched to the actual temperature profile of the TEG during operation. The performance of TEG#3 was limited by the maximum temperature allowable for the Bi-Te TE modules located in the colder end of the TEG, resulting in the operating temperature for the skutterudite modules to be considerably below optimum. We measured the power output for (1) the complete TEG (25 Watts) and (2) an individual TE module series string (1/3 of the TEG) operated at a 60°C higher temperature (19 Watts). We estimate that under optimum operating temperature conditions, TEG#3 will generate about 235 Watts. With additional improvements in thermal and electrical interfaces, temperature homogeneity, and power conditioning, we estimate TEG#3 could deliver a power output of about 425 Watts.

30 DIRECT ENERGY CONVERSION↗