Search NASA⌕ Search

SEARCH · Search NASA

Results for “nondestructive testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Calibrating and training of neutron based NSA techniques with less SNM standards

Accessing special nuclear material (SNM) standards for the calibration of and training on nondestructive assay (NDA) instruments has become increasingly difficult in light of enhanced safeguards and security regulations. Limited or nonexistent access to SNM has affected neutron based NDA techniques more than gamma ray techniques because the effects of multiplication require a range of masses to accurately measure the detector response. Neutron based NDA techniques can also be greatly affected by the matrix and impurity characteristics of the item. The safeguards community has been developing techniques for calibrating instrumentation and training personnel with dwindling numbers of SNM standards. Monte Carlo methods have become increasingly important for design and calibration of instrumentation. Monte Carlo techniques have the ability to accurately predict the detector response for passive techniques. The Monte Carlo results are usually benchmarked to neutron source measurements such as californium. For active techniques, the modeling becomes more difficult because of the interaction of the interrogation source with the detector and nuclear material; and the results cannot be simply benchmarked with neutron sources. A Monte Carlo calculated calibration curve for a training course in Indonesia of material test reactor (MTR) fuel elements assayed with an active well coincidence counter (AWCC) will be presented as an example. Performing training activities with reduced amounts of nuclear material makes it difficult to demonstrate how the multiplication and matrix properties of the item affects the detector response and limits the knowledge that can be obtained with hands-on training. A neutron pulse simulator (NPS) has been developed that can produce a pulse stream representative of a real pulse stream output from a detector measuring SNM. The NPS has been used by the International Atomic Energy Agency (IAEA) for detector testing and training applications at the Agency due to the lack of appropriate SNM standards. This paper will address the effect of reduced access to SNM for calibration and training of neutron NDA applications along with the advantages and disadvantages of some solutions that do not use standards, such as the Monte Carlo techniques and the NPS.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nondestructive Examination (NDE) Detection and Characterization of Degradation Precursors, Technical Progress Report for FY 2012

The overall objective of this project was to investigate the effectiveness of nondestructive examination (NDE) technology in detecting material degradation precursors by initiating and growing cracks in selected materials and using NDE methods to measure crack precursors prior to the onset of cracking. Nuclear reactor components are subject to stresses over time that are not precisely known and that make the life expectancy of components difficult to determine. To prevent future issues with the operation of these plants because of unforeseen failure of components, NDE technology is needed that can be used to identify and quantify precursors to macroscopic degradation of materials. Some of the NDE methods being researched as possible solutions to the precursor detection problem are magnetic Barkhausen noise, nonlinear ultrasonics, acoustic emission, eddy current measurements, and guided wave technology. In FY12, the objective was to complete preliminary assessment of advanced NDE techniques for sensitivity to degradation precursors, using prototypical degradation mechanisms in laboratory-scale measurements. This present document reports on the deliverable that meets the following milestone: M3LW-12OR0402143 – Report detailing an initial demonstration on samples from the crack-initiation tests will be provided (demonstrating acceleration of the work).

Nondestructure examination, degradation, precursor↗

Acquisition and Processing of Passive Thermography Fatigue Test Data

Passive thermography is a large area inspection technique and is commonly used during fatigue loading of composite structures. Passive thermography allows for real time tracking of damage. This provides an accurate assessment of the damage progression as a function of load cycles and determines when the loading is stopped for ultrasonic or X-ray CT evaluations for detail damage assessment through-the-thickness. In addition, if new areas of damage growth are detected, with passive thermography, then those areas are additionally inspected with ultrasound or X-ray CT. A custom developed passive thermography inspection system for fatigue loading is presented. Passive thermography of damage progression is compared to ultrasound inspections as a function of the fatigue cycles. Discussion is made on processing of the thermal data for periodic and non-periodic thermal responses.

Thermal nondestructive evaluation↗

DESTRUCTIVE EXAMINATION OF SHIPPING PACKAGE 9975-02028

Destructive and non-destructive examinations have been performed on specified components of shipping package 9975-02028. For those attributes that were also measured during the field surveillance, no significant changes were observed. Four conditions were identified that do not meet inspection criteria. These conditions are subject to additional investigation and disposition by the Surveillance Program Authority. The conditions include: (1) The lead shield was covered with a white corrosion layer; (2) The lead shield height exceeds drawing requirements; (3) Mold was observed on the lower fiberboard subassembly; and (4) Fiberboard thermal conductivity in the axial direction exceeded the specified range. The Surveillance Program Authority was notified of these conditions and will document the disposition by surveillance report. All other observations and test results met identified criteria, or were collected for information and trending purposes. The Savannah River Site (SRS) stores packages containing plutonium (Pu) materials in the K-Area Complex (KAC). The Pu materials are packaged per the DOE 3013 Standard and stored within Model 9975 shipping packages in KAC. The KAC facility DSA (Document Safety Analysis) credits the Model 9975 package to perform several safety functions, including criticality prevention, impact resistance, containment, and fire resistance to ensure the plutonium materials remain in a safe configuration during normal and accident conditions. The Model 9975 package is expected to perform its safety function for at least 12 years from initial packaging. The DSA recognizes the degradation potential for the materials of package construction over time in the KAC storage environment and requires an assessment of materials performance to validate the assumptions of the analysis and ultimately predict service life. As part of the comprehensive Model 9975 package surveillance program, destructive examination of package 9975-02028 was performed following field surveillance in accordance with Reference. Field surveillance of the Model 9975 package in KAC included nondestructive examination of the drum, fiberboard, lead shield and containment vessels. Results of the field surveillance are provided in Attachment 1.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Generalizing synthetic data-trained acoustic predictive models to real-world measurements

Acoustic Resonance Spectroscopy (ARS) is highly sensitive to structural properties such as material, geometry, and environmental conditions; as a consequence, it can noninvasively measure internal properties that are unobservable by most other methods. Because of its sensing capabilities and low implementation cost and complexity, ARS has potential as a paradigm shift in noninvasive sensing, characterization, and monitoring applications. However, extracting specific properties from ARS measurements, comprising the vibration spectrum of a test object, is challenging due to the sensitivity of the spectra to other structural changes not being measured, e.g. manufacturing tolerances, component coupling, environmental variation, etc. Neural Networks are promising tools for identifying trends in ARS measurements, but their training typically requires large datasets, which are often impractical to obtain for real-world systems. Synthetic data can be simulated efficiently, but discrepancies between synthetic and real-world data frequently lead to poor generalization when testing on the real-world data. We propose a novel ARS model training framework that enables networks trained exclusively on synthetic ARS data to generalize effectively to real-world measurements. Our approach leverages the Correlation Alignment (CORAL) technique to enforce the extraction of features common to both synthetic and real-world domains. As a case study, we demonstrate noninvasive ARS-based pressure measurements in sealed systems. Finite element method (FEM) simulations were used to generate synthetic training data across diverse vessel configurations and pressure conditions, and model performance was then tested on real-world measurements. We demonstrate that robust machine learning models for ARS can be developed without large real-world datasets, significantly broadening the applicability of ARS for noninvasive sensing. Moreover, the approach is extensible to other sensing modalities where synthetic data are abundant but real-world data are limited.

36 MATERIALS SCIENCE↗

Material Characterization and Geometric Segmentation of a Composite Structure Using Microfocus X-Ray Computed Tomography Image-Based Finite Element Modeling

This study utilizes microfocus x-ray computed tomography (CT) slice sets to model and characterize the damage locations and sizes in thermal protection system materials that underwent impact testing. ScanIP/FE software is used to visualize and process the slice sets, followed by mesh generation on the segmented volumetric rendering. Then, the local stress fields around several of the damaged regions are calculated for realistic mission profiles that subject the sample to extreme temperature and other severe environmental conditions. The resulting stress fields are used to quantify damage severity and make an assessment as to whether damage that did not penetrate to the base material can still result in catastrophic failure of the structure. It is expected that this study will demonstrate that finite element modeling based on an accurate three-dimensional rendered model from a series of CT slices is an essential tool to quantify the internal macroscopic defects and damage of a complex system made out of thermal protection material. Results obtained showing details of segmented images; three-dimensional volume-rendered models, finite element meshes generated, and the resulting thermomechanical stress state due to impact loading for the material are presented and discussed. Further, this study is conducted to exhibit certain high-caliber capabilities that the nondestructive evaluation (NDE) group at NASA Glenn Research Center can offer to assist in assessing the structural durability of such highly specialized materials so improvements in their performance and capacities to handle harsh operating conditions can be made.

Abdul-Aziz, Ali↗

INTER-DIGITAL CAPACITIVE SENSOR FOR EVALUATING CABLE INSULATION THROUGH JACKET

Interdigital capacitive (IDC) sensors have previously been used to measure cable-age/damage indicative dielectric properties of cable insulation when placed in direct contact with the insulation. Often cable insulation is covered by a polymer jacket precluding direct contact with the insulation. As part of a continuing program to develop and evaluate nondestructive examination methods that may be applied to cable condition assessment, an IDC to measure the effect of cable polymer dielectric change through a covering jacket has been developed. The IDC consists of two fork-like electrodes facing each other with the fork tines interspersed and separated by a small gap. On one electrode, the gap is 5 mm while on the other, the gap is 2 mm. Electric field depth-of-field penetrations are similar to the electrode gaps. The electrodes are printed on a flexible substrate that can be conformed to the outside jacketed surface of a cylindrical cable, with tines parallel to the cable axis. The electrodes are connected to a broad frequency-spectral impedance meter that senses the capacitance between the narrowly gapped electrode tines. This capacitance is known to vary as a function of the permittivity of any material in close proximity to the electrodes. For jacketed cable systems, the IDC response is dominated by the jacket but, by analyzing measurements from IDC sensors with different depths-of-field penetration into the cable under test, the influence of the cable jacket material (primarily influenced by the shallow-depth-of field IDC) can be separated from the deeper-depth-of-field IDC sensing the combined effects of both jacket and underlying insulation. No other NDE method is known that is capable of sensing insulation dielectric properties through an overlying jacket.

Cable NDE, Interdigital Capacitance, Insulation Pe↗

Covariance Structure of Pu Isotopic Compositions Obtained Using FRAM 5.2

In the nondestructive assay of special nuclear materials, isotopic determination based on the analysis of high-purity Ge high-resolution gamma-ray spectra plays a pivotal role. The isotopic results, which are based on a relative measurement of peak intensities, are used to interpret data acquired using quantitative (mass) nondestructive assay methods. In the case of plutonium measurements, this includes both passive and active neutron techniques, and also calorimetry (heat). Historically, precision estimates on the Pu- isotopic composition have been generated, on a case-by-case basis, by least squares fitting algorithms embedded in the analysis codes, but all other sources of uncertainty have generally been estimated using a top-down approach by item category. A largely neglected consideration is the covariance between the reported abundances and derived quantities – notably Pu-239-effective mass, Pu-240-effective mass and specific thermal power. In this work we study the covariance structure by statistically evaluating repeat spectrum measurements of two known low burn-up heavily filtered Pu items reduced using the spectrum analysis code FRAM 5.2 and alternate standard parameter sets. For routine measurements, however, only a single spectrum from an item will typically be acquired. We therefore discuss how to generate the sought after covariance information from an individual spectrum by spectrum re-sampling, an approach which could be added to provide item specific reports, and compare the two approaches to test its reliability.

Croft, Stephen↗

Leveraging Machine Learning Capabilities for the Characterization of Irradiated Uranium: A Case Study of Analysis Methods for Nuclear Safeguards and Nuclear Forensics

Nondestructively determining the initial enrichment of irradiated uranium is a complex and laborious multivariable problem due to the presence of fission products. This work demonstrates the capabilities of machine learning to analyze gamma-ray spectral data to determine initial enrichment without knowledge of the decay time of the sample. The approach developed is agnostic to the particular scenario and is applicable to a wide variety of applications in nuclear forensics and nuclear safeguards. We irradiated 5 mg uranium standard reference materials at discrete enrichment values ranging from 0.02% to 97% 235 U (weight percent) in UT Austin’s Nuclear Engineering Teaching Laboratory TRIGA Mark II 1.1 MW research reactor, allowed each to decay for 8 hours, and then measured each sample via gamma-ray spectrometry for 50 hours post-irradiation yielding 1,400 individual gamma-ray spectra discretized into 8,192 energy bins. We then trained decision trees models to analyze individual gamma-ray spectra and estimate the associated initial enrichment without knowledge of the time since end of irradiation. We evaluated the performance of the models with a reserved test set not used for training or calibrating the model. A decision tree model constructed with this procedure achieved a mean absolute error in initial enrichment determination of 2.3% (weight percent 235 U). Next, we implemented a principal component analysis pre-processing routine of the gamma-ray spectrometry data to reduce the dimensionality of the dataset from 8,192 channels in the spectrum to 10 principal components while retaining over 99% of the inherent variance in the data. Decision tree models constructed with these data demonstrated decreased mean absolute error in enrichment determination, reduced computational time, and decreased complexity. A single decision tree model constructed with this procedure achieved a mean absolute error in initial enrichment determination of 0.05% (weight percent 235 U). Furthermore, we analyzed these models with learning curves to ensure that overfitting did not occur. The capabilities provided by these models can be naturally extended to other application-focused measurements in the fields of nuclear safeguards, nuclear forensics, and nuclear non-proliferation.

Drescher, Adam↗

Delamination Depth Imaging for Quasi-Static and Fatigue Load Testing Using Passive Thermography

Passive thermography is used to monitor small increases in temperature resulting from delamination damage formation in composite hat-stiffened panels during both quasi-static and fatigue loading. It has been observed that rapid damage formation produces heating. This is composed of two heat generation components. The first component is an instantaneous response due to an irreversible thermoelastic strain release. The second component is mechanical heating, at the interface of failure, due to fracture damage. This produces a transient rise in temperature as the heat diffuses to the surface. The first component defines the thermal start time for the transient response. A one-dimensional thermal model is fitted to the data pixel by pixel, to produce imagery of the damage depth. The results are compared to ultrasonic and X-ray CT data.

Passive thermography↗

Lead Slowing-Down Spectrometry Time Spectral Analysis for Spent Fuel Assay: FY12 Status Report

Executive Summary Developing a method for the accurate, direct, and independent assay of the fissile isotopes in bulk materials (such as used fuel) from next-generation domestic nuclear fuel cycles is a goal of the Office of Nuclear Energy, Fuel Cycle R&D, Material Protection and Control Technology (MPACT) Campaign. To meet this goal, MPACT supports a multi-institutional collaboration, of which PNNL is a part, to study the feasibility of Lead Slowing Down Spectroscopy (LSDS). This technique is an active nondestructive assay method that has the potential to provide independent, direct measurement of Pu and U isotopic masses in used fuel with an uncertainty considerably lower than the approximately 10% typical of today’s confirmatory methods. This document is a progress report for FY2012 PNNL analysis and algorithm development. Progress made by PNNL in FY2012 continues to indicate the promise of LSDS analysis and algorithms applied to used fuel assemblies. PNNL further refined the semi-empirical model developed in FY2011 based on singular value decomposition (SVD) to numerically account for the effects of self-shielding. The average uncertainty in the Pu mass across the NGSI-64 fuel assemblies was shown to be less than 3% using only six calibration assemblies with a 2% uncertainty in the isotopic masses. When calibrated against the six NGSI-64 fuel assemblies, the algorithm was able to determine the total Pu mass within <2% uncertainty for the 27 diversion cases also developed under NGSI. Two purely empirical algorithms were developed that do not require the use of Pu isotopic fission chambers. The semi-empirical and purely empirical algorithms were successfully tested using MCNPX simulations as well applied to experimental data measured by RPI using their LSDS. The algorithms were able to describe the 235U masses of the RPI measurements with an average uncertainty of 2.3%. Analyses were conducted that provided valuable insight with regard to design requirements (e.g. Pb stack size, neutron source location) of an LSDS for the purpose of assaying used fuel assemblies. Sensitivity studies were conducted that provide insight as to how the LSDS instrument can be improved by making it more sensitive to the center of the fuel assemblies. In FY2013, PNNL will continue efforts to develop and refine design requirements of an LSDS for the ultimate purpose of assaying used fuel assemblies. Future efforts will be directed toward more extensive experimental benchmarking of currently implemented time-spectra analysis algorithms.

Kulisek, Jonathan A.↗

Multipurpose Pressure Vessel Scanner and Photon Doppler Velocimetry

Critical flight hardware typically undergoes a series of nondestructive evaluation methods to screen for defects before it is integrated into the flight system. Conventionally, pressure vessels have been inspected for flaws using a technique known as fluorescent dye penetrant, which is biased to inspector interpretation. An alternate method known as eddy current is automated and can detect small cracks better than dye penetrant. A new multipurpose pressure vessel scanner has been developed to perform internal and external eddy current scanning, laser profilometry, and thickness mapping on pressure vessels. Before this system can be implemented throughout industry, a probability of detection (POD) study needs to be performed to validate the system’s eddy current crack/flaw capabilities. The POD sample set will consist of 6 flight-like metal pressure vessel liners with defects of known size. Preparation for the POD includes sample set fabrication, system operation, procedure development, and eddy current settings optimization. For this, collaborating with subject matter experts was required. This technical paper details the preparation activities leading up to the POD study currently scheduled for winter 2015/2016. Once validated, this system will be a proven innovation for increasing the safety and reliability of necessary flight hardware.Additionally, testing of frangible joint requires Photon Doppler Velocimetry (PDV) and Digital Image Correlation instrumentation. There is often noise associated with PDV data, which necessitates a frequency modulation (FM) signal-to-noise pre-test. Generally, FM radio works by varying the carrier frequency and mixing it with a fixed frequency source, creating a beat frequency which is represented by audio frequency that can be heard between about 20 to 20,000 Hz. Similarly, PDV reflects a shifted frequency (a phenomenon known as the Doppler Effect) from a moving source and mixes it with a fixed source frequency, which results in a beat frequency. However, for PDV, discerning the signal from the noise is difficult without a moving source to induce the modulation. A rotating wheel is currently being used as the moving source but its configuration is impractical and has cumbersome placement inside the current frangible joint test cell. As a way to combat this problem and verify a satisfactory signal-to-noise ratio, a reflective moving crystal piezo will be used to modulate a beat frequency, and an absorptive target will be used to block the signal in order to determine any back reflection coming from the probe and discern the true signal-to noise ratio. The piezo will be mounted and inserted onto the test table on an extendable telescopic antenna grounded by a magnetic base in the test zone. This piezo configuration will be more compatible within the test zone and allow for easy removal of the disk following acceptable signal verification and prior to frangible joint tests.Additionally, topics of what was learned and smaller tasks given at White Sands Test Facility (WSTF) will be discussed. All statements in this paper are newly gained knowledge of what I have learned, observed, and have done while at WSTF.

Ellis, Tayera↗

Uncertainty quantification in application of the enrichment meter principle for nondestructive assay of special nuclear material

The various methods of nondestructive assay (NDA) of special nuclear material (SNM) have applications in nuclear nonproliferation, including detection and identification of illicit SNM at border crossings, and quantifying SNM at nuclear facilities for safeguards. No assay method is complete without “error bars,” which provide one way of expressing confidence in the assay result. Consequently, NDA specialists typically quantify total uncertainty in terms of “random” and “systematic” components, and then specify error bars for the total mass estimate in multiple items. Uncertainty quantification (UQ) for NDA has always been important, but it is recognized that greater rigor is needed and achievable using modern statistical methods. To this end, we describe the extent to which the guideline for expressing uncertainty in measurements (GUM) can be used for NDA. Also, we propose improvements over GUM for NDA by illustrating UQ challenges that it does not address, including calibration with errors in predictors, model error, and item-specific biases. A case study is presented using low-resolution NaI spectra and applying the enrichment meter principle to estimate the U-235 mass in an item. The case study illustrates how to update the current American Society for Testing and Materials guide for application of the enrichment meter principle using gamma spectra from a NaI detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multipurpose Pressure Vessel Scanner and Photon Doppler Velocimetry

Critical flight hardware typically undergoes a series of nondestructive evaluation methods to screen for defects before it is integrated into the flight system. Conventionally, pressure vessels have been inspected for flaws using a technique known as fluorescent dye penetrant, which is biased to inspector interpretation. An alternate method known as eddy current is automated and can detect small cracks better than dye penetrant. A new multipurpose pressure vessel scanner has been developed to perform internal and external eddy current scanning, laser profilometry, and thickness mapping on pressure vessels. Before this system can be implemented throughout industry, a probability of detection (POD) study needs to be performed to validate the system's eddy current crack/flaw capabilities. The POD sample set will consist of 6 flight-like metal pressure vessel liners with defects of known size. Preparation for the POD includes sample set fabrication, system operation, procedure development, and eddy current settings optimization. For this, collaborating with subject matter experts was required. This technical paper details the preparation activities leading up to the POD study currently scheduled for winter 2015/2016. Once validated, this system will be a proven innovation for increasing the safety and reliability of necessary flight hardware. Additionally, testing of frangible joint requires Photon Doppler Velocimetry (PDV) and Digital Image Correlation instrumentation. There is often noise associated with PDV data, which necessitates a frequency modulation (FM) signal-to-noise pre-test. Generally, FM radio works by varying the carrier frequency and mixing it with a fixed frequency source, creating a beat frequency which is represented by audio frequency that can be heard between about 20 to 20,000 Hz. Similarly, PDV reflects a shifted frequency (a phenomenon known as the Doppler Effect) from a moving source and mixes it with a fixed source frequency, which results in a beat frequency. However, for PDV, discerning the signal from the noise is difficult without a moving source to induce the modulation. A rotating wheel is currently being used as the moving source but its configuration is impractical and has cumbersome placement inside the current frangible joint test cell. As a way to combat this problem and verify a satisfactory signal-to-noise ratio, a reflective moving crystal piezo will be used to modulate a beat frequency, and an absorptive target will be used to block the signal in order to determine any back reflection coming from the probe and discern the true signal-to-noise ratio. The piezo will be mounted and inserted onto the test table on an extendable telescopic antenna grounded by a magnetic base in the test zone. This piezo configuration will be more compatible within the test zone and allow for easy removal of the disk following acceptable signal verification and prior to frangible joint tests.

Ellis, Tayera↗

The Inspectability Metric: A Formalized System Of Measurement Enabling The Design For Inspection Framework

Nondestructive evaluation (NDE) engineers are often confronted with structural design choices that present challenges to meeting inspection requirements. These challenges, at best, increase the resources needed to design an inspection solution and, at worst, require resource intensive redesign of the structure. If the inspectability of the structure can be determined early in the design cycle, these challenging inspection scenarios can be avoided. The emergence of additive manufacturing has further compounded this problem by enabling the creation of highly optimized structures with no regard to inspection constraints. Design for inspection (DFI) offers a framework to integrate nondestructive evaluation (NDE) into the design process to alleviate the mechanisms that produce uninspectable designs. DFI is the concept of including inspectability in a multi-objective optimization framework so that it can be considered in parallel to other metrics such as mass and manufacturability. This allows rapid evaluation of the trade-off between design metrics to find solutions that meet the inspection needs of a particular material system, structural concept, or vehicle program. To enable DFI, there must be a system by which the inspectability of a structure can be measured. This system must be agile to produce results quickly, it must be versatile to work with the type of incomplete information one would encounter early in the design process (such as lack of inspection requirements), and it must be delivered in a form that is easily understood by designers. To meet this need, this presentation introduces the novel inspectability metric as a system to measure inspectability. The inspectability metric is a standardized, automation friendly procedure that uses simulations to determine inspectability. Along with guidelines to properly process designs and integrate with existing workflows, the inspectability metric provides a suite of simulation tests to interrogate the ability to find defects and the sensitivity to variability. The testing rubric is designed to maximize the coverage of the parameter space while minimizing the number of simulations needed. The inspectability metric has been in development in collaboration with industry partners to ensure compatibility with modern simulation tools and aerospace design workflows. In this study, we will demonstrate how the inspectability metric is able to determine the inspectability of multiple types of structures, including aerospace composites and additively manufactured parts. We will then show how the inspectability score can be plugged into existing design optimization tasks, such as structural sizing algorithms or design for manufacturing (DFM) frameworks.

Design for inspection↗

Progress on Establishing the Feasibility of Lead Slowing Down Spectroscopy for Direct Measurement of Plutonium in Used Fuel

Developing a method for the accurate, direct, and independent assay of the fissile isotopes in bulk materials (such as used fuel) of next-generation domestic nuclear fuel cycles is a goal of the Office of Nuclear Energy, Fuel Cycle R&D, Material Protection and Control Technology (MPACT) Campaign. To meet this goal, MPACT continues to support a multi-institutional collaboration to address the feasibility of Lead Slowing Down Spectroscopy (LSDS) as an active nondestructive assay method that has the potential to provide independent, direct measurement of Pu and U isotopic masses in used fuel with an uncertainty considerably lower than the approximately 10% typical of today’s confirmatory assay methods. An LSDS is comprised of a stack of lead (typically 1-6 m3) in which materials to be measured are placed in the lead and a pulse of neutrons is injected. The neutrons in this pulse lose energy due to inelastic and (subsequently) elastic scattering and the average energy of the neutrons decreases as the time increases by a well-defined relationship. In the interrogation energy region (~0.1-1000 eV) the neutrons have little energy spread (~30%) about the average neutron energy. Due to this characteristic, the energy of the (assay) neutrons can then be determined by measuring the time elapsed since the neutron pulse. By measuring the induced fission neutrons emitted from the used fuel, it is possible to determine isotopic-mass content by unfolding the unique structure of isotopic resonances across the interrogation energy region. This paper will present efforts on the development of time-spectral analysis algorithms, fast neutron detector advances, and validation and testing measurements.

Fission Chambers↗

Estimation of Syringyl Units in Wood Lignins by FT-Raman Spectroscopy

Syringyl (S) lignin content and the syringyl-to-guaiacyl (S/G) lignin ratio are important characteristics of wood and lignocellulosic biomass. While numerous methods are available for estimating S lignin units and the S/G ratio, in this work, a new method based on Raman spectroscopy that uses the 370 cm –1 Raman band-area intensity (370-area) was developed. The reliability of the Raman method for determining S content was first tested by the quantitative analysis of three syringyl lignin models by sampling them, separately, in dioxane and in Avicel. Good linear correlations between the 370 cm –1 intensity and model concentrations were obtained. Next, the percent syringyl (%S) lignin units in various woods were measured by correlating the 370 cm –1 Raman intensity data with values of S units in lignin determined by three regularly used methods, namely, thioacidolysis, DFRC, and 2D-HSQC NMR. The former two methods take into account only the monomers cleaved from β–O–4-linked lignin units, whereas the NMR method reports S content on the whole cell wall lignin. When the 370-area intensities and %S values from the regularly used methods were correlated, good linear correlations were obtained (R 2 = 0.767, 0.731, and 0.804, respectively, for the three methods). The correlation with the highest R 2 , i.e., with the 2D NMR approach, is introduced for estimating S units in wood lignins by Raman spectroscopy as, in principle, both represent the whole cell wall lignin and not just the portion of lignin that gets cleaved to release monomers. The Raman analysis method is quick, uses minimal harmful chemicals, is carried out nondestructively, and is insensitive to the wet or dry state of the sample. The only limitations are that the sample of wood contains at least 30% S and not be significantly fluorescent, although the latter can be mitigated in some cases.

09 BIOMASS FUELS↗

Differential phase acoustic microscope for micro-NDE

A differential phase scanning acoustic microscope (DP-SAM) was developed, fabricated, and tested in this project. This includes the acoustic lens and transducers, driving and receiving electronics, scanning stage, scanning software, and display software. This DP-SAM can produce mechanically raster-scanned acoustic microscopic images of differential phase, differential amplitude, or amplitude of the time gated returned echoes of the samples. The differential phase and differential amplitude images provide better image contrast over the conventional amplitude images. A specially designed miniature dual beam lens was used to form two foci to obtain the differential phase and amplitude information of the echoes. High image resolution (1 micron) was achieved by applying high frequency (around 1 GHz) acoustic signals to the samples and placing two foci close to each other (1 micron). Tone burst was used in this system to obtain a good estimation of the phase differences between echoes from the two adjacent foci. The system can also be used to extract the V(z) acoustic signature. Since two acoustic beams and four receiving modes are available, there are 12 possible combinations to produce an image or a V(z) scan. This provides a unique feature of this system that none of the existing acoustic microscopic systems can provide for the micro-nondestructive evaluation applications. The entire system, including the lens, electronics, and scanning control software, has made a competitive industrial product for nondestructive material inspection and evaluation and has attracted interest from existing acoustic microscope manufacturers.

Waters, David D.↗