Search NASA⌕ Search

SEARCH · Search NASA

Results for “phase problem”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

A linearity preserving nodal variation limiting algorithm for continuous Galerkin discretization of ideal MHD equations

A stabilized continuous Galerkin (CG) method for magnetohydrodynamics (MHD) is presented herein. Ideal, compressible inviscid MHD equations are discretized in space on unstructured meshes using piecewise linear or bilinear finite element bases to get a semi-discrete scheme. Stabilization is then introduced to the semi-discrete method in a strategy that follows the algebraic flux correction paradigm. This involves adding some artificial diffusion to the high order, semi-discrete method and mass lumping in the time derivative term. The result is a low order method that provides local extremum diminishing properties for hyperbolic systems. The difference between the low order method and the high order method is scaled element-wise using a limiter and added to the low order scheme. The limiter is solution dependent and computed via an iterative linearity preserving nodal variation limiting strategy. The stabilization also involves an optional consistent background high order dissipation that reduces phase errors. The resulting stabilized scheme is a semi-discrete method that can be applied to inviscid shock MHD problems and may be even extended to resistive and viscous MHD problems. To satisfy the divergence free constraint of the MHD equations, we add parabolic divergence cleaning to the system. Various time integration methods can be used to discretize the scheme in time. We demonstrate the robustness of the scheme by solving several shock MHD problems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atomic-Scale Structural Mapping of Active Sites in Monolayer PGM-Free Catalysts by Low-Voltage 4D-STEM

Two-dimensional (2D) materials have attracted a large amount of attention in both basic and applied fields, and scanning transmission electron microscopy (STEM) is often uniquely well-suited for characterizing the atomic-scale structure of these materials [1-4]. As a result, STEM is poised to significantly impact progress on platinum group metal (PGM)-free catalysts, which are currently under intense development to enable low-cost, commercially viable hydrogen fuel cells [5]. While recent advancements have resulted in fuel cell performance comparable to Pt catalysts by some measures [6], cell durability remains a significant challenge, limiting practical applications [7]. Catalytically active sites in PGM-free materials are proposed to be FeN4 complexes embedded in a graphene lattice (Fig. 1b) within layered or other larger materials, but this is still under debate largely due to the range of potential actives sites predicted by computational methods and lack of methods for directly validating these models [5]. Fundamental insights into the atomic structure and resulting degradation pathways of proposed active sites are therefore needed to fully understand and control cell performance and durability [6].2D materials typically make ideal samples for STEM, but those within PGM-free catalysts present additional challenges since these materials are often defect-rich, with a high density of edges, dopant atoms, etc., which significantly increase susceptibility to beam damage at standard operating voltages. This makes analysis of potential FeN4 active sites particularly challenging, since a large proportion of Fe exists at edge sites where beam-induced atomic displacements can prohibit high-resolution structural characterization [6]. Conventional dark-field imaging compounds this problem by producing less signal for a given dose and being less sensitive to light elements than dose-efficient phase contrast imaging techniques such as those enabled by four-dimensional (4D)-STEM [8-10] (Fig. 1a). Consequently, active site structural analysis is often left to methods such as low-resolution imaging combined with quantum chemical calculations [6], which hinders accurate determination of reaction and degradation mechanisms.Here, we demonstrate direct atomic-scale structural mapping of FeN4 sites by performing low-voltage 4D-STEM on a model PGM-free catalyst system with many exposed monolayer regions. To accomplish this, we pair a 30 keV aberration-corrected probe with a fast pixelated detector that has optimal performance at low beam voltages [11]. This enables us to simultaneously image light and heavy elements with high signal-to-noise by center-of-mass analysis (Fig. 1c) while minimizing beam-induced atomic displacements at sensitive sites. The monolayer nature of these materials additionally allows for experimental validation by direct comparison with multislice simulations [12] of model structures (Fig. 1d-e). This work demonstrates how low-voltage 4D-STEM will provide new insights into the atomic-scale structure and degradation mechanisms of active sites in PGM-free catalysts, facilitating the development of low-cost hydrogen fuel cells and other energy conversion technologies in the future [13].

Zachman, Michael↗

Gibbs Energy Minimization Model for Solvent Extraction with Application to Rare-Earths Recovery

The emergence of technologies in which rare-earth elements provide critical functionality has increased the demand for these materials, with important implications for supply security. Recycling provides an option for mitigating supply risk and for creating economic value from the resale of recovered materials. While solvent extraction is a proven technology for rare-earth recovery and separation, its application often requires extensive trial-and-error experimentation to estimate parameter values and determine experimental design configurations. We describe a modeling strategy based on Gibbs energy minimization that incorporates parameter estimation for required thermodynamic properties as well as process design for solvent extraction and illustrate its applicability to rare earths separation. Visualization analysis during parameter estimation revealed a linear relationship between the standard enthalpies of the extractant and respective organo-metal complexes, analogous to the additivity principle for predicting molar volumes of organic compounds. Establishing this relationship reduced the size of the parameter estimation problem and yielded good agreement between model predictions and reported equilibrium extraction data, validating the property estimates for the organic phase species. Design exploration and optimization results map the space of feasible solvent extraction column configurations and identify the set of optimal design parameter values that meet recovery and purity targets.

Critical materials↗

Reversing the Irreversible: Thermodynamic Stabilization of LiAlH 4 Nanoconfined Within a Nitrogen-Doped Carbon Host

A general problem when designing functional nanomaterials for energy storage is the lack of control over the stability and reactivity of metastable phases. Using the high-capacity hydrogen storage candidate LiAlH4 as an exemplar, we demonstrate an alternative approach to the thermodynamic stabilization of metastable metal hydrides by coordination to nitrogen binding sites within the nanopores of N-doped CMK-3 carbon (NCMK-3). The resulting LiAlH 4 @NCMK-3 material releases H 2 at temperatures as low as 126 °C with full decomposition below 240 °C, bypassing the usual Li 3 AlH 6 intermediate observed in bulk. Moreover, >80% of LiAlH 4 can be regenerated under 100 MPa H 2 , a feat previously thought to be impossible. Nitrogen sites are critical to these improvements, as no reversibility is observed with undoped CMK-3. Density functional theory predicts a drastically reduced Al–H bond dissociation energy and supports the observed change in the reaction pathway. Finally, the calculations also provide a rationale for the solid-state reversibility, which derives from the combined effects of nanoconfinement, Li adatom formation, and charge redistribution between the metal hydride and the host.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Can Cr( iii ) substitute for Al( iii ) in the structure of boehmite?

The dissolution of boehmite is a technical issue for the Al industry because of its recalcitrant nature. In fact, a similar problem exists with boehmite in nuclear waste sludge at the Hanford site in eastern Washington State, USA. Dissolution of Al phases is required to reduce the waste loadings in the final borosilicate glass waste form. Although not the most common Al-bearing species in the sludge, boehmite may become a rate limiting step in the processing of the wastes. Hanford boehmite is an order of magnitude more resistant to dissolution in hot caustic solutions than expected from surface-normalized rates. We are exploring potential intrinsic and extrinsic effects that may limit boehmite reactivity; one clue comes from microstructural analyses that indicate an association of Cr with Al in the Hanford nuclear waste. Hence, in this first paper, we investigated the potential role of chromium on the reactivity of boehmite in caustic solution. An important finding was that irrespective of the synthesis pathway, amount of Cr(III), or the resultant morphology, there was no evidence for Cr incorporation in the bulk structure, in agreement with QM calculations. In fact, electron microscopic (EM) and spectroscopic analyses showed that Cr was enriched at the (101) edges of the boehmite. However, Cr had no measurable effect on the morphology during the synthesis step. In contrast, comparison of the morphologies of the synthetic Cr-doped and pure boehmite samples after exposure to caustic solutions provided evidence that Cr inhibited the corrosion. TEM showed that Cr was not homogeneously distributed at the surface. Consequently, Cr may have partially passivated the surface by blocking discrete energetic sites on the lateral surfaces of boehmite.

1-Cra and 1-Crb↗

Antihydrogen formation from antiprotons in a pure positron plasma

This paper investigates the evolution in binding energy of antihydrogen atoms formed from stationary antiprotons located within a strongly magnetized positron plasma. Three-body recombination and a collisional cascade to deeper binding, limited by a kinetic bottleneck at a binding energy of 4T, dominate the initial antihydrogen formation process. A classical Monte-Carlo simulation is used to determine the collisional transition rate between atomic binding energies, using the drift approximation for initial conditions that allow it, and full dynamics for initial conditions resulting in chaotic motion. These transition rates are employed in determining mean energy-loss rates for an ensemble of atoms, as well as in a numerical solution of the master equation to find the rate at which atoms are formed over a range of binding energies. The highly excited atoms formed by this process separate into guiding-center drift atoms and chaotic atoms. The phase-space distributions of the atoms are investigated, along with their implications for magnetic confinement and radiative energy loss. Estimates of radiative energy loss indicate that radiation is unimportant for guiding-center atoms, but increases rapidly near the chaotic regime, taking over as the dominant energy-loss process for parameters typical of recent experiments. Furthermore, the fraction of low-magnetic field seekers is considerably larger than suggested by estimates of the magnetic moment based on guiding-center dynamics, due to effects associated with chaos.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Oxynitrided Surface Layer Produced On Ti6Al4V Titanium Alloy Under Low Temperature Glow Discharge Conditions For Medical Applications

In spite that titanium oxides increase biocompatibility of titanium implants but their functional life is limited due to the problems arising from brittles and metalosis. Therefore technology, that allow to produce composite surface layer with controlled microstructure, chemical and phase composition and surface morphology on titanium alloy and eliminates the oxides disadvantages has been existing till now is searched. The requirements of titanium and its alloys implants can be fulfill by the low-temperature glow discharge assisted oxynitriding.The paper describes the surface layer of TiO{sub 2}+TiN+Ti{sub 2}N+{alpha}Ti(N) type produced at temperature 680 deg. C that preserves mechanical properties of titanium alloy Ti6Al4V. Characteristics of produced diffusion multi-phase surface layers in range of phase composition, microstructure (SEM, TEM, XRD) and its properties, such as frictional wear resistance are presented. The biological properties in dependency to the applied sterilization method are also analyzed.Properties of produced surface layers are discussed with reference to titanium alloy. The obtained data show that produced surface layers improves titanium alloy properties both frictional wear and biological. Preliminary in vitro examinations show good biocompatibility and antithrombogenic properties.

36 MATERIALS SCIENCE↗

Parallel scalability of Hartree–Fock calculations

Quantum chemistry is increasingly performed using large cluster computers consisting of multiple interconnected nodes. For a fixed molecular problem, the efficiency of a calculation usually decreases as more nodes are used, due to the cost of communication between the nodes. This paper empirically investigates the parallel scalability of Hartree–Fock calculations. The construction of the Fock matrix and the density matrix calculation are analyzed separately. For the former, we use a parallelization of Fock matrix construction based on a static partitioning of work followed by a work stealing phase. For the latter, we use density matrix purification from the linear scaling methods literature, but without using sparsity. When using large numbers of nodes for moderately sized problems, density matrix computations are network-bandwidth bound, making purification methods potentially faster than eigendecomposition methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Nonlinear negative refraction by difference frequency generation

Negative refraction has attracted much interest for its promising capability in imaging applications. Such an effect can be implemented by negative index meta-materials, however, which are usually accompanied by high loss and demanding fabrication processes. Recently, alternative nonlinear approaches like phase conjugation and four wave mixing have shown advantages of low-loss and easy-to-implement, but associated problems like narrow accepting angles can still halt their practical applications. Here, we demonstrate theoretically and experimentally a scheme to realize negative refraction by nonlinear difference frequency generation with wide tunability, where a thin Beta barium borate slice serves as a negative refraction layer bending the input signal beam to the idler beam at a negative angle. Furthermore, we realize optical focusing effect using such nonlinear negative refraction, which may enable many potential applications in imaging science.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Curing singularities in cosmological evolution of F(R) gravity

We study F(R) modified gravity models which are capable of driving the accelerating epoch of the Universe at the present time whilst not destroying the standard Big Bang and inflationary cosmology. Recent studies have shown that a weak curvature singularity with |R| → ∞ can arise generically in viable F(R) models of present dark energy (DE) signaling an internal incompleteness of these models. In this work we study how this problem is cured by adding a quadratic correction with a sufficiently small coefficient to the F(R) function at large curvatures. At the same time, this correction eliminates two more serious problems of previously constructed viable F(R) DE models: unboundedness of the mass of a scalar particle (scalaron) arising in F(R) gravity and the scalaron overabundance problem. Such carefully constructed models can also yield both an early time inflationary epoch and a late time de Sitter phase with vastly different values of R. The reheating epoch in these combined models of primordial and present dark energy is completely different from that of the old R+R{sup 2}/6M{sup 2} inflationary model, mainly due to the fact that values of the effective gravitational constant at low and intermediate curvatures are different for positive and negative R. This changes the number of e-folds during the observable part of inflation that results in a different value of the primordial power spectrum index.

79 ASTRONOMY AND ASTROPHYSICS↗

CMS Distributed Computing Integration in the LHC sustained operations era

After many years of preparation the CMS computing system has reached a situation where stability in operations limits the possibility to introduce innovative features. Nevertheless it is the same need of stability and smooth operations that requires the introduction of features that were considered not strategic in the previous phases. Examples are: adequate authorization to control and prioritize the access to storage and computing resources, improved monitoring to investigate problems and identify bottlenecks on the infrastructure, increased automation to reduce the manpower needed for operations, effective process to deploy in production new releases of the software tools. We present the work of the CMS Distributed Computing Integration Activity that is responsible for providing a liaison between the CMS distributed computing infrastructure and the software providers, both internal and external to CMS. In particular we describe the introduction of new middleware features during the last 18 months as well as the requirements to Grid and Cloud software developers for the future.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental study of two-proton correlated emission from {sup 29}S excited states

An experiment of a {sup 29}S beam bombarding a {sup 197}Au target at an energy of 49.2 MeV/u has been performed to study the two-proton correlated emission from {sup 29}S excited states. Complete-kinematics measurements were carried out in the experiment. The relative momentum, opening angle, and relative energy of two protons, as well as the invariant mass of the final system, were deduced by relativistic-kinematics reconstruction. The {sup 27}Si-p-p coincident events were picked out under strict conditions and the phenomenon of p-p correlations was observed among these events. The mechanisms of two-proton emission were analyzed in a simple schematic model, in which the extreme decay modes like {sup 2}He cluster emission, three-body phase-space decay, and two-body sequential emission were taken into account. Associated with the Monte Carlo simulations, the present results show that two protons emitted from the excited states between 9.6 MeV and 10.4 MeV exhibit the features of {sup 2}He cluster decay with a branching ratio of 29{sub -11}{sup +10}%.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Unified origin of inflation, baryon asymmetry, and neutrino mass

In this work, we present a unified theoretical framework that simultaneously addresses some of the most intriguing puzzles in particle physics and cosmology, namely the origins of neutrino mass, baryon asymmetry, and cosmic inflation. In our model, inflation is driven by a combination of the Standard Model Higgs, the type II seesaw Higgs responsible for neutrino mass generation, and the unified symmetry-breaking Higgs field. During inflation, nonzero values of the latter field ensure the absence of the monopole problem. The baryon asymmetry is generated through the Affleck-Dine mechanism, facilitated by the nonzero angular motion in the phase of a complex scalar field, which is part of the inflaton. We find that the successful parameter region for generating baryon asymmetry through a renormalizable term in the scalar potential requires a rather heavy type II seesaw triplet, with a mass well beyond the TeV scale. Inflationary observables, in particular, the spectral index is in excellent agree with experimental observation, whereas tensor-to scalar ratio is expected to be probed by the future LiteBIRD and CMB-S4 missions. Published by the American Physical Society 2024

Kaladharan, Ajay (ORCID:0000000165096427)↗

Uniform redundancy allocation maximizes the robustness of flow networks against cascading failures

We study the robustness of flow networks against cascading failures under a partial load redistribution model. In particular, we consider a flow network of N lines with initial loads L 1 ,...,L N and free spaces (i.e., redundant space) S 1 ,...,S N that are independent and identically distributed with joint distribution P LS (x,y) = P[L ≤ x, S ≤ y]. The capacity C i is the maximum load allowed on line i and is given by C i = L i + S i . Furthermore, when a line fails due to overloading, it is removed from the system and (1 – ε) fraction of the load it was carrying is redistributed equally among all remaining lines in the system. The rest (i.e., ε fraction) of the load is assumed to be lost or absorbed, e.g., due to advanced circuitry disconnecting overloaded power lines or an interconnected network or material absorbing a fraction of the flow from overloaded lines. We analyze the robustness of this flow network against random attacks that remove a p fraction of the lines. Our contributions include (i) deriving the final fraction of alive lines n ∞ (p,ε) for all p,εϵ(0,1) and confirming the results via extensive simulations; (ii) showing that partial redistribution might lead to (depending on the parameter 0 < ε ≤ 1) the order of transition at the critical attack size p* changing from first to second-order; and (iii) proving analytically that flow networks achieve maximum robustness [quantified by the area ∫$^{1}_{0}$ n ∞ (p,ε)dp] when all lines have the same free space regardless of their initial load. The optimality of equal free-space allocation is also confirmed on real-world data from the UK National Power Grid.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Improving Signal-to-Noise Ratio (SNR) for Readout Signals Using Adaptive Filters on Reconfigurable Controls Hardware

This study investigates the optimization of Signal-to-Noise Ratio (SNR) in superconducting quantum computing readout signals through adaptive filtering. Quantum computing technology has the potential to revolutionize various fields by delivering exponential speedup in solving certain computational problems. However, the technology's practical implementation is hindered by the difficulty of extracting clean, reliable signals during the readout phase, with various sources of noise presenting a significant barrier to clean signals. This noise, often present in readout profiles due to imperfect isolation, degrades the system's overall SNR, thus impeding the ability to extract the quantum state accurately. The research leverages the power of adaptive filtering to improve the SNR of quantum computing readout signals. Specifically, an adaptive filter is implemented in a PYNQ overlay on an FPGA, and eventually will be connected to a quantum computing system. The system models the noise with a Least Mean Squares (LMS) adaptive filter, and then subtracts the estimated noise from the received signal to improve the SNR. A Direct Memory Access (DMA) channel is used to handle the signal processing, delivering efficient, high-speed data transfer between the PYNQ system and the hardware. The study explores the benefits of this adaptive filtering technique, potentially providing a significant contribution to practical and fast quantum computing.

Johnson, Hans↗

TH-A-207B-00: Shear-Wave Imaging and a QIBA US Biomarker Update

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

TH-A-207B-01: Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗

TH-A-207B-02: QIBA Ultrasound Elasticity Imaging System Biomarker Qualification and User Testing of Systems

Imaging of tissue elastic properties is a relatively new and powerful approach to one of the oldest and most important diagnostic tools. Imaging of shear wave speed with ultrasound is has been added to most high-end ultrasound systems. Understanding this exciting imaging mode aiding its most effective use in medicine can be a rewarding effort for medical physicists and other medical imaging and treatment professionals. Assuring consistent, quantitative measurements across the many ultrasound systems in a typical imaging department will constitute a major step toward realizing the great potential of this technique and other quantitative imaging. This session will target these two goals with two presentations. A. Basics and Current Implementations of Ultrasound Imaging of Shear Wave Speed and Elasticity - Shigao Chen, Ph.D. Learning objectives-To understand: Introduction: Importance of tissue elasticity measurement Strain vs. shear wave elastography (SWE), beneficial features of SWE The link between shear wave speed and material properties, influence of viscosity Generation of shear waves External vibration (Fibroscan) ultrasound radiation force Point push Supersonic push (Aixplorer) Comb push (GE Logiq E9) Detection of shear waves Motion detection from pulse-echo ultrasound Importance of frame rate for shear wave imaging Plane wave imaging detection How to achieve high effective frame rate using line-by-line scanners Shear wave speed calculation Time to peak Random sample consensus (RANSAC) Cross correlation Sources of bias and variation in SWE Tissue viscosity Transducer compression or internal pressure of organ Reflection of shear waves at boundaries B. Elasticity Imaging System Biomarker Qualification and User Testing of Systems – Brian Garra, M.D. Learning objectives-To understand: Goals Review the need for quantitative medical imaging Provide examples of quantitative imaging biomarkers Acquaint the participant with the purpose of the RSNA Quantitative Imaging Biomarker Alliance and the need for such an organization Review the QIBA process for creating a quantitative biomarker Summarize steps needed to verify adherence of site, operators, and imaging systems to a QIBA profile Underlying Premise and Assumptions Objective, quantifiable results are needed to enhance the value of diagnostic imaging in clinical practice Reasons for quantification Evidence based medicine requires objective, not subjective observer data Computerized decision support tools (eg CAD) generally require quantitative input. Quantitative, reproducible measures are more easily used to develop personalized molecular medical diagnostic and treatment systems What is quantitative imaging? Definition from Imaging Metrology Workshop The Quantitative Imaging Biomarker Alliance Formation 2008 Mission Structure Example Imaging Biomarkers Being Explored Biomarker Selection Groundwork Draft Protocol for imaging and data evaluation QIBA Profile Drafting Equipment and Site Validation Technical Clinical Site and Equipment QA and Compliance Checking Ultrasound Elasticity Estimation Biomarker US Elasticity Estimation Background Current Status and Problems Biomarker Selection-process and outcome US SWS for Liver Fibrosis Biomarker Work Groundwork Literature search and analysis results Phase I phantom testing-Elastic phantoms Phase II phantom testing-Viscoelastic phantoms Digital Simulated Data Protocol and Profile Drafting Protocol: based on UPICT and existing literature and standards bodies protocols Profile-Current claims, Manufacturer specific appendices What comes after the profile Profile Validation Technical validation Clinical validation QA and Compliance Possible approaches Site Operator testing Site protocol re-evaluation Imaging system Manufacturer testing and attestation User acceptance testing and periodic QA Phantom Tests Digital Phantom Based Testing Standard QA Testing Remediation Schemes Profile Evolution Towards additional applications Towards higher accuracy and precision Supported in part by NIH contract HHSN268201300071C from NIBIB. Collaboration with GE Global Research, no personal support.; S. Chen, Some technologies described in this presentation have been licensed. Mayo Clinic and Dr. Chen have financial interests these technologies.

60 APPLIED LIFE SCIENCES↗