Search NASA⌕ Search

SEARCH · Search NASA

Results for “polymerization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

The Design and Development of a Regenerative Separatory Column Using Calixarenes as a Polymeric Backbone for the Purification of Water from Urine

The objective of this research project is to design calixarenes, cup-shaped molecules, with the specific binding sites to the sodium chloride and nitrogen containing components of urine, such as urea and uric acid, in urine. The following partition of the research accomplishes this objective: (1) functionalization of calixarene, (2) development of a calixarene based medium for the separatory process, (3) design of the column regeneration protocol. Work was also accomplished in the area of temperature sensitive paint (TSP). Research was undertaken to design a TSP with insulating propertites. An important part of this research project is to discover the thermal conductivity of polymers for TSP.

Polk, M.↗

Synthesis and Development of Porous Polymeric Column Packing and Microchip Detectors for GC Analysis of Extraterrestrial Atmospheres

This report summarizes the last nine years research accomplishments under Cooperative Agreement NCC2-650 between NASA, Ames Research Center and SETI Institute. Four Major research tasks are conducted: 1. Gas chromatography column development. 2. Pyrosensor development. 3. Micro-machining gas chromatography instrument development. 4. Amino acid analysis and high molecular weight polyamino acid synthesis under prebiotic conditions. The following describes these results.

Shen, Thomas C.↗

Assessment of Uncertainty in the Determination of Activation Energy for Polymeric Materials

An assessment of the experimental uncertainty in obtaining the kinetic activation energy from thermogravimetric analysis (TGA) data is presented. A neat phenolic resin, Borden SC1O08, was heated at three heating rates to obtain weight loss vs temperature data. Activation energy was calculated by two methods: the traditional Flynn and Wall method based on the slope of log(q) versus 1/T, and a modification of this method where the ordinate and abscissa are reversed in the linear regression. The modified method produced a more accurate curve fit of the data, was more sensitive to data nonlinearity, and gave a value of activation energy 75 percent greater than the original method. An uncertainty analysis using the modified method yielded a 60 percent uncertainty in the average activation energy. Based on this result, the activation energy for a carbon-phenolic material was doubled and used to calculate the ablation rate In a typical solid rocket environment. Doubling the activation energy increased surface recession by 3 percent. Current TGA data reduction techniques that use the traditional Flynn and Wall approach to calculate activation energy should be changed to the modified method.

Darby, Stephania P.↗

Formation of Metallic Nanophases in Polymeric Matrices for Space Applications

There are a select number of polyimides which are soluble in organic media. Incorporation of hexafluoroisopropylidene groups is a route to achieving solubility. Such fluorinated polyimides have desirable properties for processing and electronic purposes; however, they often have linear coefficients of thermal expansion (CTE) which are well above those for metals and inorganic oxides or ceramics with which they might be bonded. We have developed a synthesis of composite inorganic-polyimide films using diaquotris(2,4-pentane-dionato)lanthanam(III) as the inorganic precursor and two soluble polyimides formed from 2,2-bis(3,4- dicarboxyphenyl)hexafluoro-propane (6FDA) and 1,3-bis(3-aminophenoxy)benzene (APB) or 2,2-bis[4-(4-aminophenoxy)phenyllhexafluoropropane (4-BDAF). A primary goal of our work was to control the linear CTE in these fluorinated polymer composites without adversely affecting mechanical or other thermal properties.

Orwoll, Robert A.↗

Microgravity Processing and Photonic Applications of Organic and Polymeric Materials

In recent years, a great deal of interest has been directed toward the use of organic materials in the development of high-efficiency optoelectronic and photonic devices. There is a myriad of possibilities among organic which allow flexibility in the design of unique structures with a variety of functional groups. The use of nonlinear optical (NLO) organic materials such as thin-film waveguides allows full exploitation of their desirable qualities by permitting long interaction lengths and large susceptibilities allowing modest power input. There are several methods in use to prepare thin films, such as Langmuir-Blodgett (LB) and self-assembly techniques, vapor deposition, growth from sheared solution or melt, and melt growth between glass plates. Organics have many features that make Abstract: them desirable for use in optical devices such as high second- and third-order nonlinearities, flexibility of molecular design, and damage resistance to optical radiation. However, their use in devices has been hindered by processing difficulties for crystals and thin films. In this chapter, we discuss photonic and optoelectronic applications of a few organic materials and the potential role of microgravity on processing these materials. It is of interest to note how materials with second- and third-order nonlinear optical behavior may be improved in a diffusion-limited environment and ways in which convection may be detrimental to these materials. We focus our discussion on third-order materials for all-optical switching, and second-order materials for all-optical switching, and second-order materials for frequency conversion and electrooptics.

Frazier, Donald 0↗

Gravitational Influences on the Growth of Polydiacetylene Films by Ultraviolet Solution Polymerization

Technically, the field of integrated optics using organic/polymer materials as a new means of information processing, has emerged as of vital importance to optical computers, optical switching, optical communications, the defense industry, etc. The goal is to replace conventional electronic integrated circuits and wires by equivalent miniaturized optical integrated circuits and fibers, offering larger bandwidths, more compactness and reliability, immunity to electromagnetic interference and less cost. From the Code E perspective, this research area represents an opportunity to marry "front-line" education in science and technology with national scientific and technological interests while maximizing human resources utilization. This can be achieved by the development of untapped resources for scientific research - such as minorities, women, and universities traditionally uninvolved in scientific research.

Frazier, Donald O.↗

The Design and Synthesis of Epoxy Matrix Composites Curable by Electron Beam Induced Cationic Polymerization

Several new series of novel, high reactivity epoxy resins are described which are designed specifically for the fabrication of high performance carbon fiber reinforced composites for commercial aircraft structural applications using cationic UV and e-beam curing. The objective of this investigation is to provide resin matrices which rapidly and efficiently cure under low e-beam doses which are suitable to high speed automated composite fabrication techniques such as automated tape and tow placement. It was further the objective of this work to provide resins with superior thermal, oxidative and atomic oxygen resistance.

Crivello, James V.↗

Electrical Impedance of Ionic Polymeric Metal Composites

In recent years the use of ionic polymer metal composites such as Nafion-based platinum ionomers have emerged as electroactive polymer materials with great potential for robotics and other applications. An effective activation of these materials requires understanding of their mechanism of operation. Generally, the material needs to be maintained hydrated to assure its electromechanical activity. To allow the control of the response of the material, a study is underway to investigate the electrical response. Particular emphasis is placed on possible electrochemical reactions and deviations from linear dielectric behavior. Currently, efforts are made to determine the necessary drive characteristics of the source to allow low power operation (< or = 1.0 W) of the material as an actuator.

Leary, S.↗

Effects of Electrons, Protons, and Ultraviolet Radiation on Thermophysical Properties of Polymeric Films

The response of coated thin polymer films to ultraviolet (UV), electron and proton radiation simultaneously has been evaluated, with selected measurements in situ. Exposure was intended to simulate the electron and proton radiation environment near the Earth-Sun Lagrangian points (LI and L2) for five years and approximately 1000 equivalent solar hours (ESH) UV. These orbital environments are relevant to several potential missions such as the Next Generation Space Telescope and Geomagnetic Storm Warning, both of which may use thin film based structures for a sunshade and solar sail, respectively. The thin film candidates (12.5 micrometers thick) consisted of commercially available materials (Kapton(R) E, HN, Upilex(R) S, CP-1, CP-2, TOR-RC, and TOR-LMBP) that were metalized on one side with vapor deposited aluminum. All of the films are aromatic polyimides, with the exception of TORLMBP, which is a copoly(arylene ether benzimidazole). The films were exposed as second surface mirrors and the effects of the exposure on solar absorptance, thermal emittance, and tensile properties were determined. The in situ changes in solar absorptance from Kapton(R) and Upilex(R) were less than 0. 1, whereas the solar absorptance of TOR and CP films increased by more than 0.3 without saturating. The thermal emittance measurements also showed that the Kapton(R) and Upilex(R) materials increased only 1-2%, but the remaining materials increased 5-8%. Based on tensile property measurements made in air following the test, the failure stress of every type of polymer film decreased as a result of irradiation. The polymers most stable in reflectance, namely Upilex(R) and Kapton(R), were also the strongest in tension before irradiation, and they retained the greatest percentage of tensile strength. The films less stable in reflectance were also weaker in tension, and lost more tensile strength as a result of irradiation. The apparent failure strain (as a percent of original gage length) of every type of polymer film except TOR-RC, decreased as a result of irradiation.

Russell, Dennis A.↗

Microstructure and Properties of Thermally Sprayed Functionally Graded Coatings for Polymeric Substrates

The use of polymer matrix composites (PMCs) in the gas flow path of advanced turbine engines offers significant benefits for aircraft engine performance but their useful lifetime is limited by their poor erosion resistance. High velocity oxy-fuel (HVOF) sprayed polymer/cermet functionally graded (FGM) coatings are being investigated as a method to address this technology gap by providing erosion and oxidation protection to polymer matrix composites. The FGM coating structures are based on a polyimide matrix filled with varying volume fractions of WC-Co. The graded coating architecture was produced using a combination of internal and external feedstock injection, via two computer-controlled powder feeders and controlled substrate preheating. Porosity, coating thickness and volume fraction of the WC-Co filler retained in the coatings were determined using standard metallographic techniques and computer image analysis. The pull-off strength (often referred to as the adhesive strength) of the coatings was evaluated according to the ASTM D 4541 standard test method, which measured the greatest normal tensile force that the coating could withstand. Adhesive/cohesive strengths were determined for three different types of coating structures and compared based on the maximum indicated load and the surface area loaded. The nature and locus of the fractures were characterized according to the percent of adhesive and/or cohesive failure, and the tested interfaces and layers involved were analyzed by Scanning Electron Microscopy.

Ivosevic, M.↗

Characterization of Viscoelastic Properties of Polymeric Materials Through Nanoindentation

Nanoindentation is used to determine the dynamic viscoelastic properties of six polymer materials. It is shown that varying the harmonic frequency of the nanoindentation does not have any significant effect on the measured storage and loss moduli of the polymers. Agreement is found between these results and data from DMA testing of the same materials. Varying the harmonic amplitude of the nanoindentation does not have a significant effect on the measured properties of the high performance resins, however, the storage modulus of the polyethylene decreases as the harmonic amplitude increases. Measured storage and loss moduli are also shown to depend on the density of the polyethylene.

Odegard, G. M.↗

Changes in Polymeric Tether Properties Due to Atomic Oxygen

The Propulsive Small Expendable Deployer System (ProSEDS) mission is designed to provide an on-orbit demonstration of the electrodynamic propulsion capabilities of tethers in space. The ProSEDS experiment will be a secondary payload on a Delta II unmanned expendable booster. A 5-km conductive tether is attached to the Delta II second stage and collects current fiom the low Earth orbit (LEO) plasma to facilitate de-orbit of the spent stage. The conductive tether is attached to a 10-km non-conductive tether, which is then attached to an endmass containing several scientific instruments. Atomic oxygen (AO) erodes most organic materials. As the orbit of the Delta II second stage decas, the AO flux (atoms/sq cm sec) increases. A nominal AO fluence of 1 x l0(exp 21) atoms/sq cm was agreed upon by the investigators as an adequate level for evaluating the performance of the tether materials. A test series was performed to determine the effect of atomic oxygen (AO) on the mechanical integrity and possible strength loss of ProSEDS tether materials. The tether materials in this study were Dyneema, an ultra-high molecular weight polyethylene material used as the non-conducting portion of the ProSEDS tether, and the Kevlar core strength fiber used in the conductive tether. Samples of Dyneema and Kevlar were exposed to various levels of atomic oxygen up to 1.07 x 10(exp 21) atoms/sq cm in the Marshall Space Flight Center Atomic Oxygen Beam Facility (AOBF). Changes in mass were noted after AO exposure. The tethers were then tensile-tested until failure. AO affected both the Dyneema and Kevlar tether material strength. Dyneema exposed to 1.07 x 10(exp 21) atoms/sq cm of atomic oxygen failed due to normal handling when removed fiom the AOBF and was not tensile-tested. Another test series was performed to determine the effect of AO on the electrical properties of the ProSEDS conductive tether. The conductive tether consists of seven individually coated strands of 28 AWG 1350-0 aluminum wire. The conductive coating, developed by Triton Systems, Inc., is a mix of polyanaline and COR, a clear AO-resistant polymer.

Finckenor, Miria M.↗

Accelerated Testing of Polymeric Composites Using the Dynamic Mechanical Analyzer

Creep properties of IM7/K3B composite material were obtained using three accelerated test methods at elevated temperatures. Results of flexural creep tests using the dynamic mechanical analyzer (DMA) were compared with results of conventional tensile and compression creep tests. The procedures of the three test methods are described and the results are presented. Despite minor differences in the time shift factor of the creep compliance curves, the DMA results compared favorably with the results from the tensile and compressive creep tests. Some insight is given into establishing correlations between creep compliance in flexure and creep compliance in tension and compression. It is shown that with careful consideration of the limitations of flexure creep, a viable and reliable accelerated test procedure can be developed using the DMA to obtain the viscoelastic properties of composites in extreme environments.

Abdel-Magid, Becky M.↗

Tensile Properties of Polymeric Matrix Composites Subjected to Cryogenic Environments

Polymer matrix composites (PMC s) have seen limited use as structural materials in cryogenic environments. One reason for the limited use of PMC s in cryogenic structures is a design philosophy that typically requires a large, validated database of material properties in order to ensure a reliable and defect free structure. It is the intent of this paper to provide an initial set of mechanical properties developed from experimental data of an advanced PMC (IM7/PETI-5) exposed to cryogenic temperatures and mechanical loading. The application of this data is to assist in the materials down-select and design of cryogenic fuel tanks for future reusable space vehicles. The details of the material system, test program, and experimental methods will be outlined. Tension modulus and strength were measured at room temperature, -196 C, and -269 C on five different laminates. These properties were also tested after aging at -186 C with and without loading applied. Microcracking was observed in one laminate.

Whitley, Karen S.↗

Polymerization of beta-amino acids in aqueous solution

We have compared carbonyl diimidazole (CDI) and 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide (EDAC) as activating agents for the oligomerization of negatively-charged alpha- and beta-amino acids in homogeneous aqueous solution. alpha-Amino acids can be oligomerized efficiently using CDI, but not by EDAC. beta-Amino acids can be oligomerized efficiently using EDAC, but not by CDI. Aspartic acid, an alpha- and beta-dicarboxylic acid is oligomerized efficiently by both reagents. These results are explained in terms of the mechanisms of the reactions, and their relevance to prebiotic chemistry is discussed.

NASA Discipline Exobiology↗

In-situ polymerized PLOT columns III: divinylbenzene copolymers and dimethacrylate homopolymers

Studies of divinylbenzene copolymers and dimethacrylate homopolymers indicate that the polymer pore size controls the separation of water and ammonia on porous-layer-open-tubular (PLOT) columns. To a lesser degree, the polarity of the polymers also affects the separation of a water-ammonia gas mixture. Our results demonstrate that the pore size can be regulated by controlling the cross-linking density or the chain length between the cross-linking functional groups. An optimum pore size will provide the best separation of water and ammonia.

NASA Discipline Exobiology↗

Polymerization on the rocks: negatively-charged alpha-amino acids

Oligomers of the negatively-charged amino acids, glutamic acid, aspartic acid, and O-phospho-L-serine are adsorbed by hydroxylapatite and illite with affinities that increase with oligomer length. In the case of oligo-glutamic acids adsorbed on hydroxylapatite, addition of an extra residue results in an approximately four-fold increase in the strength of adsorption. Oligomers much longer than the 7-mer are retained tenaciously by the mineral. Repeated incubation of short oligo-glutamic acids adsorbed on hydroxylapatite or illite with activated monomer leads to the accumulation of oligomers at least 45 units long. The corresponding reactions of aspartic acid and O-phospho-L-serine on hydroxylapatite are less effective in generating long oligomers, while illite fails to accumulate substantial amounts of long oligomers of aspartic acid or of O-phospho-L-serine.

NASA Discipline Exobiology↗