Search NASA⌕ Search

SEARCH · Search NASA

Results for “scan pattern”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Growth of nanostructured molybdenum disulfide (MoS 2 ) thin films on a nanohole-patterned substrate using plasma-enhanced atomic layer deposition (ALD)

Nanostructured molybdenum disulfide (MoS 2 ) thin films were grown on a nanohole-patterned silicon substrate using plasma-enhanced atomic layer deposition. A nanoscale hole-patterned silicon substrate was fabricated for the growth of MoS 2 film using the self-assembly-based nanofabrication method. The nanoscale holes can significantly increase the surface area of the substrate while the formation and growth of nanostructures normally start at the surface of the substrate. Hydrogen sulfide (H 2 S) gas was used as the S source in the growth of molybdenum disulfide (MoS 2 ) while molybdenum (V) chloride (MoCl 5 ) powder was used as the Mo source. The MoS 2 film had a stoichiometric ratio of 1 (Mo) to 2 (S), and had peaks of E 1 2g and A 1g , which represent the in-plane and out-plane vibration modes of the Mo–S bond, respectively. It was found that the MoS 2 film grown in the nanoscale hole, especially at the wall of the hole, has more hexagonal-like structures due to the effects of nanoscale space confinement and the nanoscale interface although the film shows an amorphous structure. Post-growth high-temperature annealing ranging from 800 to 900 °C produced local crystalline structures in the film, which are compatible with those reported by other researchers.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Preparation and optical properties of Zn{sub 0.85}Sb{sub 0.1}O alloy films

Graphical abstract: Top SEM image (a) and SAED pattern (b) of ZnSbO film grown on Si(1 1 1) substrate at 600 °C. Highlights: ► We discuss the deposition of ZnSbO thin films by pulsed laser deposition (PLD). ► The films showed a high resistivity of ∼10{sup 4} Ω cm, suggesting the efficient compensation of intrinsic donor-like defects. ► The ternary Zn{sub 0.9}Sb{sub 0.1}O film show a reduction in the band gap of ∼ 40 meV with reference to undoped ZnO films. - Abstract: Zn{sub 0.85}Sb{sub 0.1}O films were synthesized by pulsed laser deposition (PLD). The X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS) and photoluminescence (PL) measurements were carried out to evaluate the microstructure of the films. These films exhibited a single-phase hexagonal structure with (0 0 2) preferred orientation, despite the high Sb content of ∼10% and the resulting large lattice distortion in the films. Moreover, the films showed semiconductor properties with high resistivity of ∼10{sup 4} Ω cm, which was possibly related to a compensation of intrinsic defects. Compared with the undoped ZnO, a reduction in the band gap by 40 meV was clearly observed in ultraviolet–visible absorption spectra.

36 MATERIALS SCIENCE↗

Alpha image reconstruction (AIR): A new iterative CT image reconstruction approach using voxel-wise alpha blending

Purpose: Iterative image reconstruction gains more and more interest in clinical routine, as it promises to reduce image noise (and thereby patient dose), to reduce artifacts, or to improve spatial resolution. Among vendors and researchers, however, there is no consensus of how to best achieve these aims. The general approach is to incorporatea priori knowledge into iterative image reconstruction, for example, by adding additional constraints to the cost function, which penalize variations between neighboring voxels. However, this approach to regularization in general poses a resolution noise trade-off because the stronger the regularization, and thus the noise reduction, the stronger the loss of spatial resolution and thus loss of anatomical detail. The authors propose a method which tries to improve this trade-off. The proposed reconstruction algorithm is called alpha image reconstruction (AIR). One starts with generating basis images, which emphasize certain desired image properties, like high resolution or low noise. The AIR algorithm reconstructs voxel-specific weighting coefficients that are applied to combine the basis images. By combining the desired properties of each basis image, one can generate an image with lower noise and maintained high contrast resolution thus improving the resolution noise trade-off. Methods: All simulations and reconstructions are performed in native fan-beam geometry. A water phantom with resolution bar patterns and low contrast disks is simulated. A filtered backprojection (FBP) reconstruction with a Ram-Lak kernel is used as a reference reconstruction. The results of AIR are compared against the FBP results and against a penalized weighted least squares reconstruction which uses total variation as regularization. The simulations are based on the geometry of the Siemens Somatom Definition Flash scanner. To quantitatively assess image quality, the authors analyze line profiles through resolution patterns to define a contrast factor for contrast-resolution plots. Furthermore, the authors calculate the contrast-to-noise ratio with the low contrast disks and the authors compare the agreement of the reconstructions with the ground truth by calculating the normalized cross-correlation and the root-mean-square deviation. To evaluate the clinical performance of the proposed method, the authors reconstruct patient data acquired with a Somatom Definition Flash dual source CT scanner (Siemens Healthcare, Forchheim, Germany). Results: The results of the simulation study show that among the compared algorithms AIR achieves the highest resolution and the highest agreement with the ground truth. Compared to the reference FBP reconstruction AIR is able to reduce the relative pixel noise by up to 50% and at the same time achieve a higher resolution by maintaining the edge information from the basis images. These results can be confirmed with the patient data. Conclusions: To evaluate the AIR algorithm simulated and measured patient data of a state-of-the-art clinical CT system were processed. It is shown, that generating CT images through the reconstruction of weighting coefficients has the potential to improve the resolution noise trade-off and thus to improve the dose usage in clinical CT.

60 APPLIED LIFE SCIENCES↗

Effect of isovalent substitution on microstructure and phase transition of LaNb{sub 1−x}M{sub x}O{sub 4} (M=Sb, V or Ta; x=0.05–0.3)

LaNb{sub 1−x}M{sub x}O{sub 4} oxides with pentavalent elements of different ionic sizes (M=Sb, Ta and V, x=0.05–0.3) were synthesized by the solid state reaction method. Special interest was devoted to the antimony substituted lanthanum niobate which is a new material in this group. Rietveld analysis of the X-ray diffraction patterns was used to determine the influence of the material composition on unit cell parameters. On the basis of dilatometric measurements phase transition temperatures and thermal expansion coefficients of the studied materials were determined. It was shown that with increasing concentration of Sb the phase transition temperature decreases. Thermal expansion coefficient of the antimony substituted samples above the transition temperature is in the range from 8.1 to 9.1×10{sup −6} 1/K, whereas below the transition temperature the TEC value is between 14 and 17.3×10{sup −6} 1/K. Influence of Ta, V and Sb substitutions on the microstructure and grain size was studied. - Graphical abstract: Substitution of niobium by other pentavalent elements in LaNbO{sub 4} leads to change in phase transition temperature. In case of Sb substituent a shift of phase transition into the lower temperature region is observed. LaNb{sub 0.7}Sb{sub 0.3}O{sub 4} substitution allows to achieve material with tetragonal crystal structure at room temperature and no phase transition up to 1000 °C. - Highlights: • Antimony doped lanthanum niobate was successfully synthesized by solid state synthesis method. • The structural properties have been investigated by XRD and SEM. • The influence of doping on phase transition temperature has been studied.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fast-MICP for frameless image-guided surgery

Purpose: In image-guided surgery (IGS) systems, image-to-physical registration is critical for reliable anatomical information mapping and spatial guidance. Conventional stereotactic frame-based or fiducial-based approaches provide accurate registration but are not patient-friendly. This study proposes a frameless cranial IGS system that uses computer vision techniques to replace the frame or fiducials with the natural features of the patient. Methods: To perform a cranial surgery with the proposed system, the facial surface of the patient is first reconstructed by stereo vision. Accuracy is ensured by capturing parallel-line patterns projected from a calibrated LCD projector. Meanwhile, another facial surface is reconstructed from preoperative computed tomography (CT) images of the patient. The proposed iterative closest point (ICP)-based algorithm [fast marker-added ICP (Fast-MICP)] is then used to register the two facial data sets, which transfers the anatomical information from the CT images to the physical space. Results: Experimental results reveal that the Fast-MICP algorithm reduces the computational cost of marker-added ICP (J.-D. Lee et al., ''A coarse-to-fine surface registration algorithm for frameless brain surgery,'' in Proceedings of International Conference of the IEEE Engineering in Medicine and Biology Society, 2007, pp. 836-839) to 10% and achieves comparable registration accuracy, which is under 3 mm target registration error (TRE). Moreover, two types of optical-based spatial digitizing devices can be integrated for further surgical navigation. Anatomical information or image-guided surgical landmarks can be projected onto the patient to obtain an immersive augmented reality environment. Conclusion: The proposed frameless IGS system with stereo vision obtains TRE of less than 3 mm. The proposed Fast-MICP registration algorithm reduces registration time by 90% without compromising accuracy.

60 APPLIED LIFE SCIENCES↗

Wet chemical synthesis of ZnO-CdS composites and their photocatalytic activity

Highlights: • ZnO-CdS composites were synthesized by wet chemical method. • TEM, correlated SAED pattern, XRD, and SEM confirmed the structure of composites. • CdS amount added during composites synthesis influences their morphologies. • RhB degradation efficiency is higher for composites than that of pristine ZnO, depending on the catalyst morphology. - Abstract: The present study is focused on the wet chemical synthesis and the characterization of ZnO-CdS composites. The X-ray diffraction shows that the composites contain ZnO in hexagonal wurtzite structure and CdS in cubic phase. The scanning/transmission electron microscopy images reveal flower-like structures with different sizes depending on the CdS content. The optical investigations on composites reveal that the reflectance spectra disclose two thresholds of ∼370 nm and ∼460 nm associated with the ZnO and CdS, respectively. The photocatalytic activity measurements evidenced that the degradation efficiency of RhB in the presence of composites is higher comparatively with pristine ZnO, depending on the catalyst morphology, which varies with CdS content and the pH value of RhB solution. The electron paramagnetic resonance revealed the presence of the paramagnetic point defects in the samples. Thus, the wet chemical approaches are suitable for a large scale production of such ZnO-CdS composites having enhanced photocatalytic activity.

36 MATERIALS SCIENCE↗

Potential underestimation of the internal target volume (ITV) from free-breathing CBCT

Purpose: Localization prior to delivery of SBRT to free-breathing patients is performed by aligning the planning internal target volume (ITV) from 4DCT with an on-board free-breathing cone-beam CT (FB-CBCT) image. The FB-CBCT image is assumed to also generate an ITV that captures the full range of motion, due to the acquisition spanning multiple respiratory cycles. However, the ITV could potentially be underestimated when the ratio of time spent in inspiration versus time spent in expiration (I/E ratio) deviates from unity. Therefore, the aim of this study was to investigate the effect of variable I/E ratios on the FB ITV generated from a FB-CBCT scan. Methods: This study employed both phantom and patient imaging data. For the phantom study, five periodic respiratory cycles were simulated with different I/E ratios. Six patient respiratory cycles with variable I/E ratios were also selected. All profiles were then programmed into a motion phantom for imaging and modified to exhibit three peak-to-peak motion amplitudes (0.5, 1.0, and 2.0 cm). Each profile was imaged using two spherical targets with 1.0 and 3.0 cm diameters. 2D projections were acquired with full gantry rotation of a kiloVoltage (kV) imager mounted onto the gantry of a modern linear accelerator. CBCT images were reconstructed from 2D projections using a standard filtered back-projection reconstruction algorithm. Quantitative analyses for the phantom study included computing the change in contrast along the direction of target motion as well as determining the area (which is proportional to the target volume) inside of the contour extracted using a Canny edge detector. For the patient study, projection data that were previously acquired under an investigational 4D CBCT slow-gantry imaging protocol were used to generate both FB-CBCT and 4D CBCT images. Volumes were then manually contoured from both datasets (using the same window and level) for quantitative comparison. Results: The phantom study indicated a reduction in contrast at the inferior edge of the ITV (corresponding to inspiration) as the ratio decreased, for both simulated and patient respiratory cycles. For the simulated phantom respiratory cycles, the contrast reduction of the smallest I/E ratio was 27.6% for the largest target with the smallest amplitude and 89.7% for the smallest target with the largest amplitude. For patient respiratory cycles, these numbers were 22.3% and 94.0%, respectively. The extracted area from inside of the target contours showed a decreasing trend as the I/E ratio decreased. In the patient study, the FB-CBCT ITVs of both lung tumors studied were underestimated when compared with their corresponding 4D CBCT ITV. The underestimations found were 40.1% for the smaller tumor and 24.2% for the larger tumor. Conclusions: The ITV may be underestimated in a FB-CBCT image when a patient's respiratory pattern is characterized by a disparate length of time spent in inspiration versus expiration. Missing the full target motion information during on-board verification imaging may result in localization errors.

61 RADIATION PROTECTION AND DOSIMETRY↗

Ion Transport in 2D Nanostructured $\pi$-Conjugated Thieno[3,2- b ]thiophene-Based Liquid Crystal

Leveraging the self-assembling behavior of liquid crystals designed for controlling ion transport is of both fundamental and technological significance. Here, we have designed and prepared a liquid crystal that contains (2,5-bis(5-(2,5,8,11-tetraoxatridecan-13-yl)thiophen-2yl)thieno[3,2-b]thiophene (BTTT) as mesogenic core and conjugated segment and symmetric tetra(ethylene oxide) (EO4) as polar side chains for ionic conducting regions. Driven by the crystallization of the BTTT cores, BTTT/dEO4 exhibits well-ordered smectic phases below 71.5 °C as confirmed by differential scanning calorimetry, polarized optical microscope, temperature dependent wide-angle X-ray scattering and grazing incidence wide-angle X-ray scattering (GIWAXS). We adopted a combination of experimental GIWAXS and molecular dynamics (MD) simulations to better understand the molecular packing of BTTT/dEO4 films, particularly when loaded with the ion conducting salt, lithium bis(trifluoromethanesulfonyl)imide (LiTFSI). Ionic conduction of BTTT/dEO4 is realized by the addition of LiTFSI, with the material able to maintain smectic phases up to r = [Li + ]/[EO] = 0.1. In this work, The highest ionic conductivity of 8 × 10 -3 S/cm was attained at an intermedium salt concentration of r = 0.05. It was also found that ion conduction in BTTT/dEO4 is enhanced by forming a smectic layered structure with irregular interfaces between the BTTT and EO4 layers and by the lateral film expansion upon salt addition. This can be explained by the enhancement of the misalignment and configurational entropy of the side chains, which increase their local mobility and that of the solvated ions. Our molecular design thus illustrates how, beyond the favorable energetic interactions that drive the assembly and ion solvating domains, modulation of entropic effects can also be favorably harnessed to improve ion conduction.

thin film electrochemical impedance spectroscopy↗

A modified method for barium titanate nanoparticles synthesis

Graphical abstract: TEM micrograph of BaTiO{sub 3} powders synthesized at 800 Degree-Sign C for 1 h and SAED pattern (inset) of BaTiO{sub 3} powders. In this research, a modified, cost efficient and quick sol-gel procedure was used for preparation of BaTiO{sub 3} nanoparticles. Highlights: Black-Right-Pointing-Pointer A modified process was used for preparation. Black-Right-Pointing-Pointer The modified process led to preparation of finer BaTiO{sub 3} nanoparticles in shorter period of time and lower temperature contrary to previous researches. Black-Right-Pointing-Pointer The proposed procedure seems to be more preferable for mass production. -- Abstract: In this research, a modified, cost effective sol-gel procedure applied to synthesize BaTiO{sub 3} nanoparticles. XRD and electron microscopy (SEM and TEM) applied for microstructural characterization of powders. The obtained results showed that the type of precursors, their ratio and the hydrolysis conditions had a great effect on time, temperature and therefore the costs of the synthesis process. By selection, utilization of optimized precursor's type, hydrolysis conditions, fine cubic BaTiO{sub 3} nanoparticles were synthesized at low temperature and in short time span (1 h calcination at 800 Degree-Sign C). The proposed procedure seems to be more preferable for mass production. The result indicated that the polymorphic transformation to tetragonal (ferroelectric characteristic) occurred at 900 Degree-Sign C, which might be an indication of being nanosized.

36 MATERIALS SCIENCE↗

FABRICATION OF BISMUTH NANOWIRE DEVICES USING FOCUSED ION BEAM MILLING

In this work, a focused ion beam (FIB) milling process has been developed to fabricate 50 nm Bi nanowire and transistor structures using FEI-200 dual beam FIB system. For the fabrication, 50 nm bismuth film was thermally evaporated through EBL patterned PMMA windows onto SiO{sub 2} substrates with pre-defined contact pads. Bi nanowire widths ranging from 30 nm to 100 nm have been successfully fabricated by milling out unwanted areas using 30 KeV Ga+ ion beam. A single-pixel-line ion beam blanking technique has been utilised to fabricate Bi nanowire as small as 30 nm in diameter and few micrometers long. In order to form good ohmic contacts for sub 50 nm bismuth nanowires, a drill-and-fill process has been developed using FIB to sputter away the surface oxide of bismuth after the in-situ platinum nanowire contacts deposition. To our knowledge, this is the first time a focused ion beam process has been used to fabricate bismuth nanowire. The fabricated Bi nanowires were electrically characterised using a semiconductor analyser that showed good ohmic contact to the electrodes. In this paper, the fabrication experiments and the characterisation results for Bi nanowires as small as 50 nm in diameter are presented. Several FIB issues involved in Bi device making and ohmic contacts to Bi nanowires will also be discussed.

36 MATERIALS SCIENCE↗

Epidemiologic Study of One Million U.S. Radiation Workers and Veterans

The single most important question in radiation epidemiology is determining the level of health risks associated with radiation exposures that occur gradually over time. The study of one million early U.S. radiation workers and veterans has been designed to provide information on risk following chronic exposures by focusing on occupational groups with differing radiation exposure patterns, including intakes of radionuclides. The cost-efficient study builds on the investments made and foundations laid by investigators and government agencies over the past 30-40 years, which have established early worker cohorts that can now provide answers to questions on the lifetime human health risks associated with low-level radiation exposures. Within the overall goal of the epidemiologic study of one million U.S. radiation workers and veterans, this project had a total of nine specific aims which included studies of six populations for multiple endpoints including cancer overall mortality, leukemia and non-cancer mortality. The six populations included: Mound, Ohio, workers exposed to polonium, tritium and plutonium; nuclear power plant workers within the Landauer dosimetry and Nuclear Regulatory Commission data files; industrial radiographers; Mallinckrodt uranium workers; uranium workers who linked with the US Renal Data System; and nuclear weapons test participants. Over 400,000 workers and atomic veterans are included in these populations, with vital status being determined and analyses of all causes of death undertaken. A critical, integral component of the studies has been comprehensive evaluations of dosimetry involving, in many cases, complex dose reconstructions, and assessments of uncertainties. The work has also involved development of state-of-the art statistical approaches and modeling. All nine aims were accomplished successfully, resulting in publication of two NCRP documents, 13 literature papers, numerous Boice Reports in Health Physics News and many presentations of the work at scientific meetings. Furthermore, recommendations have been developed for an approach to integrate epidemiologic observations with radiation biology for risk assessment and biological models of radiation effect. The results of this project, as well as ongoing epidemiology studies of US radiation workers and veterans, are providing much-needed insights into complex issues regarding cancer and non-cancer health risks from low dose irradiation, how to apply a "dose and dose rate effectiveness factor" to scale the risks from the A-bomb survivor data to current occupational and environmental circumstances, and how to evaluate risk following intakes of radioactive substances. In addition to application to radiation workers, the results of the studies can provide guidance as society debates the role of nuclear energy and deals with nuclear waste, threats of terrorist attacks with nuclear/radiological devices, the remarkable increase in medical exposures to CT scans and nuclear imaging, and to NASA as radiation protection for astronauts on long-duration mission beyond low-Earth orbit is planned.

61 RADIATION PROTECTION AND DOSIMETRY↗

The influences of mole composition of strontium (x) on properties of barium strontium titanate (Ba{sub 1−x}Sr{sub x}TiO{sub 3}) prepared by solid state reaction method

Barium Strontium Titanate (Ba{sub 1-x}Sr{sub x}TiO{sub 3}) or BST was prepared by solid state reaction method. Raw materials are BaCO{sub 3}, SrCO{sub 3}, and TiO{sub 2}. Those materials are mixed for 8 h, pressed, and sintered at temperature 1200°C for 2 h. Mole composition of Sr (x) was varied to study its influences on structural, morphological, and electrical properties of BST. Variation of (x) are x = 0; x = 0.1; and x = 0.5. XRD patterns showed a single phase of BST, which mean that mixture of raw materials was homogenous. Crystal structure was influenced by x. BaTiO{sub 3} and Ba{sub 0.9}Ti{sub 0.1}TiO{sub 3} have tetragonal crystal structure, while Ba{sub 0.5}Sr{sub 0.5}TiO{sub 3} is cubic. The diffraction angle shifted to right side (angle larger) as the increases of x. Crystalline size of BaTiO{sub 3}, Ba{sub 0.9}Sr{sub 0.1}TiO{sub 3}, and Ba{sub 0.5}Sr{sub 0.5}TiO{sub 3} are 38.13 nm; 38.62 nm; and 37.13 nm, respectively. SEM images showed that there are still of pores which were influenced by x. Ba{sub 0.9}Sr{sub 0.1}TiO{sub 3} has densest surface (pores are few and small in size). Sawyer Tower circuit showed that BaTiO{sub 3} and Ba{sub 0.9}Sr{sub 0.1} TiO{sub 3} is ferroelectric, while Ba{sub 0.5}Sr{sub 0.5}TiO{sub 3} is paraelectric. The dielectric constants of BaTiO{sub 3}, Ba{sub 0.9}Sr{sub 0.1}TiO{sub 3} and Ba{sub 0.5}Sr{sub 0.5}TiO{sub 3} at frequency of 1 KHz are 156; 196; and 83, respectively. Ba{sub 0.9}Sr{sub 0.1}TiO{sub 3} has relatively highest dielectric constant. It is considered that Ba{sub 0.9}Sr{sub 0.1}TiO{sub 3} has densest surface.

36 MATERIALS SCIENCE↗

Experimental validation of heterogeneity-corrected dose-volume prescription on respiratory-averaged CT images in stereotactic body radiotherapy for moving tumors

The purpose of this study was to experimentally assess the validity of heterogeneity-corrected dose-volume prescription on respiratory-averaged computed tomography (RACT) images in stereotactic body radiotherapy (SBRT) for moving tumors. Four-dimensional computed tomography (CT) data were acquired while a dynamic anthropomorphic thorax phantom with a solitary target moved. Motion pattern was based on cos (t) with a constant respiration period of 4.0 sec along the longitudinal axis of the CT couch. The extent of motion (A{sub 1}) was set in the range of 0.0-12.0 mm at 3.0-mm intervals. Treatment planning with the heterogeneity-corrected dose-volume prescription was designed on RACT images. A new commercially available Monte Carlo algorithm of well-commissioned 6-MV photon beam was used for dose calculation. Dosimetric effects of intrafractional tumor motion were then investigated experimentally under the same conditions as 4D CT simulation using the dynamic anthropomorphic thorax phantom, films, and an ionization chamber. The passing rate of {gamma} index was 98.18%, with the criteria of 3 mm/3%. The dose error between the planned and the measured isocenter dose in moving condition was within {+-} 0.7%. From the dose area histograms on the film, the mean {+-} standard deviation of the dose covering 100% of the cross section of the target was 102.32 {+-} 1.20% (range, 100.59-103.49%). By contrast, the irradiated areas receiving more than 95% dose for A{sub 1} = 12 mm were 1.46 and 1.33 times larger than those for A{sub 1} = 0 mm in the coronal and sagittal planes, respectively. This phantom study demonstrated that the cross section of the target received 100% dose under moving conditions in both the coronal and sagittal planes, suggesting that the heterogeneity-corrected dose-volume prescription on RACT images is acceptable in SBRT for moving tumors.

61 RADIATION PROTECTION AND DOSIMETRY↗

Mie Scattering and Resonant Plasmon Polaritons for Nano-Ablation Patterning

This paper describes the comparative study of near-field nano-processing of glass and silicon by use of metallic nano-particle and dielectric nano-particle excited by an 820 nm near-infrared femtosecond laser pulse. Near electromagnetic field around metallic nano-particle and dielectric particle shows quite unique properties on the substrate to be near-field processed. It is found that the existing thought that the use of the metallic particle is better than the dielectric particle in a much smaller particle size region than excitation wavelength is NOT always correct. As for near-field enhancement on low refractive index glass substrates by the dielectric particle with appropriate refractive index, an enhancement factor at the TE1 (magnetic dipole mode) resonance mode is found to be higher than that induced by gold particle even at the TM1 (electric dipole mode) resonance mode of gold particle. Conversely, on a high refractive index substrate like silicon, the near-field enhancement factor becomes larger by use of the gold particle at the same particle size. This significant change of the enhanced field intensity stems from the different nature of power flow based on the image charge induced in the substrate. These results indicate that the best combination of the particle and substrate for efficient localized near-field nano-processing is important for selecting either the metallic or dielectric particle. The obtained result gives a useful means for the particle selection and understanding of near-field interaction physics with substrate for efficient nano-processing of the substrate surface. Finally, these theoretical results have been verified by experiment.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Large scale synthesis of nanostructured zirconia-based compounds from freeze-dried precursors

Nanocrystalline zirconia powders have been obtained at the multigram scale by thermal decomposition of precursors resulting from the freeze-drying of aqueous acetic solutions. This technique has equally made possible to synthesize a variety of nanostructured yttria or scandia doped zirconia compositions. SEM images, as well as the analysis of the XRD patterns, show the nanoparticulated character of those solids obtained at low temperature, with typical particle size in the 10-15 nm range when prepared at 673 K. The presence of the monoclinic, the tetragonal or both phases depends on the temperature of the thermal treatment, the doping concentration and the nature of the dopant. In addition, Rietveld refinement of the XRD profiles of selected samples allows detecting the coexistence of the tetragonal and the cubic phases for high doping concentration and high thermal treatment temperatures. Raman experiments suggest the presence of both phases also at relatively low treatment temperatures. - Graphical abstract: Zr{sub 1-x}A{sub x}O{sub 2-x/2} (A=Y, Sc; 0{<=}x{<=}0.12) solid solutions have been prepared as nanostructured powders by thermal decomposition of precursors obtained by freeze-drying, and this synthetic procedure has been scaled up to the 100 g scale. Highlights: Black-Right-Pointing-Pointer Zr{sub 1-x}A{sub x}O{sub 2-x/2} (A=Y, Sc; 0{<=}x{<=}0.12) solid solutions have been prepared as nanostructured powders. Black-Right-Pointing-Pointer The synthetic method involves the thermal decomposition of precursors obtained by freeze-drying. Black-Right-Pointing-Pointer The temperature of the thermal treatment controls particle sizes. Black-Right-Pointing-Pointer The preparation procedure has been scaled up to the 100 g scale. Black-Right-Pointing-Pointer This method is appropriate for the large-scale industrial preparation of multimetallic systems.

36 MATERIALS SCIENCE↗

The influence of diffusion temperature on the structural, optical and magnetic properties of manganese-doped zinc oxysulfide thin films

We investigated the structural, optical and magnetic properties of Mn-doped zinc oxysulfide films. Zn(O,S) films were deposited by a spray pyrolysis method on glass substrate. A thin Mn layer evaporated on these films served as the source for the diffusion doping. The XRD pattern of undoped films revealed the presence of two wurtzite phases corresponding to ZnS and ZnO with a strong preferred orientation along the ZnS (0 0 2) hexagonal plane direction. SEM showed a similar surface morphology for the undoped and Mn-doped films, displaying regular arrays of hexagonal micro-rods perpendicular to the substrate. The optical transmission measurements showed that both undoped and Mn diffusion-doped films had a low average transmittance less than about 10%. The gap energy is decreased from 3.42 to 3.33 eV upon annealing at 400 deg. C. Photoluminescence studies at 300 K show that the incorporation of manganese leads to a decrease of deep level band intensity compared to undoped sample. Clear ferromagnetic loops were observed for the Mn-doped Zn(O,S) films, which might be due to the presence of point defects. - Graphical abstract: M-H variation of Mn diffusion-doped Zn(O,S) thin films measured at 300 K. Highlights: > Zinc oxysulfide thin films fabricated by spray pyrolysis and doped with Mn. > Regular arrays of hexagonal micro-rods perpendicular to the substrate. > Optical transmission measurements showed that both undoped and Mn diffusion-doped films had a low average transmittance less than about 10%. > Magnetic measurements show that Mn-doped zinc oxysulfide thin films exhibit a ferromagnetism behavior at room temperature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthesis of Self-Assembled rGO-Co{sub 3}O{sub 4} Nanoparticles in Nanorods Structure for Supercapacitor Application

A simple hydrothermal process was used to design self-assembled Co{sub 3}O{sub 4} nanoparticles in nanorod structure in the presence of graphene oxide as a template. The as-prepared Co{sub 3}O{sub 4} sample in a loose powder form was calcined at 450 °C to get the well-crystalline phase of the same compound. The obtained Co{sub 3}O{sub 4} powder sample was characterized by using the powder XRD and SEM. The XRD pattern shows totally nine distinct reflection peaks of (111), (220), (311), (222), (400), (422), (511), (440), and (533) planes. The most intense peaks were chosen to evaluate the structural parameters. The lattice parameters (a), volume (V), and density (ρ) of the samples are 8.09 Å, 529.47 Å{sup 3}, 6.06 g/cc, which are comparable to the value of lattice parameter (a = 8.056 Å), volume (V = 528.30 Å{sup 3}), and density (ρ = 6.055 gm/cc) for bulk Co{sub 3}O{sub 4}. The average size of the Co{sub 3}O{sub 4} nanoparticles is 14 nm which is smaller than the SEM size of 50 nm corresponding to the agglomeration of tiny particles. Further, the formation of Co{sub 3}O{sub 4} nanoparticles were also confirmed by obtaining the band at 569, 1334,1337, 1566, and 3397 cm{sup −1} in FTIR spectrum. Totally five characteristics peaks from Co{sub 3}O{sub 4} at 182.57, 456.49, 505.84, 605.80, and 618.02 cm{sup −1} and peaks from GO-Co{sub 3}O{sub 4} at 182.57, 483.44, 505.84, 605.80, and 618.02 cm{sup −1} corresponding to F{sub 2g}, E{sub g}, F{sub 2g}, F{sub 2g,} and A{sub g} modes of the crystalline Co{sub 3}O{sub 4}, respectively, in the Raman spectra. In the case of GO-Co{sub 3}O{sub 4} composite, low-intensity peaks of D and G bands are observed. The specific capacitance in rGO-Co{sub 3}O{sub 4} nanocomposite is about 65.15 Fg{sup −1}.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Automated Radiation Targeting in Head-and-Neck Cancer Using Region-Based Texture Analysis of PET and CT Images

Purpose: A co-registered multimodality pattern analysis segmentation system (COMPASS) was developed to automatically delineate the radiation targets in head-and-neck cancer (HNC) using both {sup 18}F-fluoro-deoxy glucose-positron emission tomography (PET) and computed tomography (CT) images. The performance of the COMPASS was compared with the results of existing threshold-based methods and radiation oncologist-drawn contours. Methods and Materials: The COMPASS extracted texture features from corresponding PET and CT voxels. Using these texture features, a decision-tree-based K-nearest-neighbor classifier labeled each voxel as either 'normal' or 'abnormal.' The COMPASS was applied to the PET/CT images of 10 HNC patients. Automated segmentation results were validated against the manual segmentations of three radiation oncologists using the volume, sensitivity, and specificity. The performance of the COMPASS was compared with three PET-based threshold methods: standard uptake value of 2.5, 50% maximal intensity, and signal/background ratio. Results: The tumor delineations of the COMPASS were both quantitatively and qualitatively more similar to those of the radiation oncologists than the delineations from the other methods. The specificity was 95% {+-} 2%, 84% {+-} 9%, 98% {+-} 3%, and 96% {+-} 4%, and the sensitivity was 90% {+-} 12%, 93% {+-} 10%, 48% {+-} 20%, and 68% {+-} 25% for the COMPASS, for a standard uptake value of 2.5, 50% maximal intensity, and signal/background ratio, respectively. The COMPASS distinguished HNC from adjacent normal tissues with high physiologic uptake and consistently defined tumors with large variability in {sup 18}F-fluoro-deoxy glucose uptake, which are often problematic with the threshold-based methods. Conclusion: Automated segmentation using texture analysis of PET/CT images has the potential to provide accurate delineation of HNC. This could lead to reduced interobserver variability, reduced uncertainty in target delineation, and improved treatment planning accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗