Search NASA⌕ Search

SEARCH · Search NASA

Results for “simulator study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Experimental Investigation and Monte Carlo Simulation of Quasielastic Electron Scattering From Helium-3 Clusters in Helium-4

Experiment E04-018 was conducted in Hall A of the Jefferson National Laboratory (JLab) from November 2006 through July 2007. The experiment used the two superconducting, high-resolution magnetic spectrometers of Hall A to detect scattered electrons and recoil nuclei. One goal of this experiment was to provide accurate data on the elastic charge form factor of 4He to high momentum transfers (up to Q2 = 77 fm?2). The purpose of this thesis is to analyze and simulate a very unique and unexpected class of data from this experiment. The work performed involved the analysis of electron scattering data with the 4He target of the JLab E04-018 experiment and Monte Carlo simulation studies of elastic and quasielastic electron scattering from the 4He and 3He few-body nuclear systems. The results of this experiment and the simulations provide insights into the existence of A = 3 clustering in 4He, and possibly in heavier nuclei.

Alahmade, Walaa↗

Correction for FDG PET dose extravasations: Monte Carlo validation and quantitative evaluation of patient studies

Purpose: Current procedure guidelines for whole body [18F]fluoro-2-deoxy-D-glucose (FDG)-positron emission tomography (PET) state that studies with visible dose extravasations should be rejected for quantification protocols. Our work is focused on the development and validation of methods for estimating extravasated doses in order to correct standard uptake value (SUV) values for this effect in clinical routine. Methods: One thousand three hundred sixty-seven consecutive whole body FDG-PET studies were visually inspected looking for extravasation cases. Two methods for estimating the extravasated dose were proposed and validated in different scenarios using Monte Carlo simulations. All visible extravasations were retrospectively evaluated using a manual ROI based method. In addition, the 50 patients with higher extravasated doses were also evaluated using a threshold-based method. Results: Simulation studies showed that the proposed methods for estimating extravasated doses allow us to compensate the impact of extravasations on SUV values with an error below 5%. The quantitative evaluation of patient studies revealed that paravenous injection is a relatively frequent effect (18%) with a small fraction of patients presenting considerable extravasations ranging from 1% to a maximum of 22% of the injected dose. A criterion based on the extravasated volume and maximum concentration was established in order to identify this fraction of patients that might be corrected for paravenous injection effect. Conclusions: The authors propose the use of a manual ROI based method for estimating the effectively administered FDG dose and then correct SUV quantification in those patients fulfilling the proposed criterion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Four dimensional magnetic resonance imaging with retrospective k-space reordering: A feasibility study

Purpose: Current four dimensional magnetic resonance imaging (4D-MRI) techniques lack sufficient temporal/spatial resolution and consistent tumor contrast. To overcome these limitations, this study presents the development and initial evaluation of a new strategy for 4D-MRI which is based on retrospective k-space reordering. Methods: We simulated a k-space reordered 4D-MRI on a 4D digital extended cardiac-torso (XCAT) human phantom. A 2D echo planar imaging MRI sequence [frame rate (F) = 0.448 Hz; image resolution (R) = 256 × 256; number of k-space segments (N{sub KS}) = 4] with sequential image acquisition mode was assumed for the simulation. Image quality of the simulated “4D-MRI” acquired from the XCAT phantom was qualitatively evaluated, and tumor motion trajectories were compared to input signals. In particular, mean absolute amplitude differences (D) and cross correlation coefficients (CC) were calculated. Furthermore, to evaluate the data sufficient condition for the new 4D-MRI technique, a comprehensive simulation study was performed using 30 cancer patients’ respiratory profiles to study the relationships between data completeness (C{sub p}) and a number of impacting factors: the number of repeated scans (N{sub R}), number of slices (N{sub S}), number of respiratory phase bins (N{sub P}), N{sub KS}, F, R, and initial respiratory phase at image acquisition (P{sub 0}). As a proof-of-concept, we implemented the proposed k-space reordering 4D-MRI technique on a T2-weighted fast spin echo MR sequence and tested it on a healthy volunteer. Results: The simulated 4D-MRI acquired from the XCAT phantom matched closely to the original XCAT images. Tumor motion trajectories measured from the simulated 4D-MRI matched well with input signals (D = 0.83 and 0.83 mm, and CC = 0.998 and 0.992 in superior–inferior and anterior–posterior directions, respectively). The relationship between C{sub p} and N{sub R} was found best represented by an exponential function (C{sub P}=100(1−e{sup −0.18N{sub R}}), when N{sub S} = 30, N{sub P} = 6). At a C{sub P} value of 95%, the relative error in tumor volume was 0.66%, indicating that N{sub R} at a C{sub P} value of 95% (N{sub R,95%}) is sufficient. It was found that N{sub R,95%} is approximately linearly proportional to N{sub P} (r = 0.99), and nearly independent of all other factors. The 4D-MRI images of the healthy volunteer clearly demonstrated respiratory motion in the diaphragm region with minimal motion induced noise or aliasing. Conclusions: It is feasible to generate respiratory correlated 4D-MRI by retrospectively reordering k-space based on respiratory phase. This new technology may lead to the next generation 4D-MRI with high spatiotemporal resolution and optimal tumor contrast, holding great promises to improve the motion management in radiotherapy of mobile cancers.

60 APPLIED LIFE SCIENCES↗

Studies of vortex dominated flows; Proceedings of the Symposium, Hampton, VA, July 9-11, 1985

Papers are presented on waves and bifurcations in vortex filaments, a ring-vortex representation of an axisymmetric vortex sheet, and comparison of experiment with the dynamics of the von Karman vortex trail. Also considered are force-free and loss-free transitions between vortex flow states, a vortex breakdown simulation based on a nonlinear inviscid method, and the prediction of highly vortical flows using an Euler equation model. Other topics include the theory of high-Reynolds-number flow past a blunt body, progress on the calculation of large-scale separation at high Reynolds numbers, and viscous-inviscid interaction solvers and computation of highly separated flows. Papers are also presented on simulation studies of vortex dynamics of a leading edge vortex flap, methods for numerical simulation of leading edge vortex flow, and comparison of measured and computed pitot pressures in a leading edge vortex from a delta wing.

Hussaini, M. Y.↗

Design and Validation of Control Room Upgrades Using a Research Simulator Facility

Since 1981, the United States (U.S.) Nuclear Regulatory Commission (NRC) [1] requires a plant- specific simulator facility for use in training at U.S. nuclear power plants (NPPs). These training simulators are in near constant use for training and qualification of licensed NPP operators. In the early 1980s, the Halden Man-Machine Laboratory (HAMMLab) at the Halden Reactor Project (HRP) in Norway first built perhaps the most well known set of research simulators. The HRP offered a high- fidelity simulator facility in which the simulator is functionally linked to a specific plant but in which the human-machine interface (HMI) may differ from that found in the plant. As such, HAMMLab incorporated more advanced digital instrumentation and controls (I&C) than the plant, thereby giving it considerable interface flexibility that researchers took full advantage of when designing and validating different ways to upgrade NPP control rooms. Several U.S. partners—the U.S. NRC, the Electrical Power Research Institute (EPRI), Sandia National Laboratories, and Idaho National Laboratory (INL) – as well as international members of the HRP, have been working with HRP to run control room simulator studies. These studies, which use crews from Scandinavian plants, are used to determine crew behavior in a variety of normal and off-normal plant operations. The findings have ultimately been used to guide safety considerations at plants and to inform advanced HMI design—both for the regulator and in industry. Given the desire to use U.S. crews of licensed operators on a simulator of a U.S. NPP, there is a clear need for a research simulator facility in the U.S. There is no general-purpose reconfigurable research oriented control room simulator facility in the U.S. that can be used for a variety of studies, including the design and validation of control room upgrades.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Jet transport flight operations using cockpit display of traffic information during instrument meteorological conditions: Simulation evaluation

A simulation study was undertaken to evaluate flight operations using cockpit display of traffic information (CDTI) in a conventional jet transport aircraft. Eight two-person airline flight crews participated as test subjects flying simulated terminal area approach and departure operations under instrument meteorological conditions (IMC). A fixed-base cockpit simulator configured with a full complement of conventional electromechanical instrumentation to permit full workload operations was utilized. Traffic information was displayed on a color cathode-ray tube (CRT) mounted above the throttle quadrant in the typical weather radar location. A transparent touchpanel overlay was utilized for pilot interface with the display. Air traffic control (ATC) simulation included an experienced controller and full partyline radio environment for evaluation of pilot-controlled self-separation and traffic situation monitoring tasks. Results of the study revealed the CDTI to be well received by the test subjects as a useful system which could be incorporated into an existing jet transport cockpit. Crew coordination and consistent operating procedures were identified as important considerations in operational implementation of traffic displays. Cockpit workload was increased with active CDTI tasks. However, all test subjects rated the increase to be acceptable.

Williams, David H.↗

WE-FG-BRA-06: Systematic Study of Target Localization for Bioluminescence Tomography Guided Radiation Therapy for Preclinical Research

Purpose: To overcome the limitation of CT/CBCT in guiding radiation for soft tissue targets, we developed a bioluminescence tomography(BLT) system for preclinical radiation research. We systematically assessed the system performance in target localization and the ability of resolving two sources in simulations, phantom and in vivo environments. Methods: Multispectral images acquired in single projection were used for the BLT reconstruction. Simulation studies were conducted for single spherical source radius from 0.5 to 3 mm at depth of 3 to 12 mm. The same configuration was also applied for the double sources simulation with source separations varying from 3 to 9 mm. Experiments were performed in a standalone BLT/CBCT system. Two sources with 3 and 4.7 mm separations placed inside a tissue-mimicking phantom were chosen as the test cases. Live mice implanted with single source at 6 and 9 mm depth, 2 sources with 3 and 5 mm separation at depth of 5 mm or 3 sources in the abdomen were also used to illustrate the in vivo localization capability of the BLT system. Results: Simulation and phantom results illustrate that our BLT can provide 3D source localization with approximately 1 mm accuracy. The in vivo results are encouraging that 1 and 1.7 mm accuracy can be attained for the single source case at 6 and 9 mm depth, respectively. For the 2 sources study, both sources can be distinguished at 3 and 5 mm separations at approximately 1 mm accuracy using 3D BLT but not 2D bioluminescence image. Conclusion: Our BLT/CBCT system can be potentially applied to localize and resolve targets at a wide range of target sizes, depths and separations. The information provided in this study can be instructive to devise margins for BLT-guided irradiation and suggests that the BLT could guide radiation for multiple targets, such as metastasis. Drs. John W. Wong and Iulian I. Iordachita receive royalty payment from a licensing agreement between Xstrahl Ltd and Johns Hopkins University.

60 APPLIED LIFE SCIENCES↗

Sensitivity of the strength and toughness of concrete to the properties of the interfacial transition zone

We report Civil infrastructure is made primarily of concrete structures or components and therefore understanding durability and fracture behavior of concrete is of utmost importance. Concrete contains an interfacial transition zone (ITZ), a porous region surrounding the aggregates, that is often considered to be the weakest region in the concrete. The ITZ is poorly characterized and property estimates for the ITZ differ considerably. In this simulation study, representative concrete mesostructures are produced by packing coarse aggregates with realistic geometries into a mortar matrix. A meshless numerical method, peridynamics, is utilized to simulate the mechanical response including fracture under uniaxial compression and tension. The sensitivity of the stiffness and fracture toughness of the samples to the ITZ properties is computed, showing strong relationships between the ITZ properties and the effective modulus and effective yield strength of the concrete. These results provides insight into the influence of the poorly characterized ITZ on the stiffness and strength of concrete. This work showcases the applicability of peridynamics to concrete systems, matching experimental strength and modulus values. Additionally, relationships between the ITZ’s mechanical properties and the overall concrete strength and stiffness are presented to enable future design decisions.

36 MATERIALS SCIENCE↗

Detector requirements and simulation results for the EIC exclusive, diffractive and tagging physics program using the ECCE detector concept

This article presents a collection of simulation studies using the ECCE detector concept in the context of the EIC’s exclusive, diffractive, and tagging physics program, which aims to further explore the rich quark–gluon structure of nucleons and nuclei. To successfully execute the program, ECCE proposed to utilize the detector system close to the beamline to ensure exclusivity and tag ion beam/fragments for a particular reaction of interest. Preliminary studies confirm the proposed technology and design satisfy the requirements. Further, the projected physics impact results are based on the projected detector performance from the simulation at 10 or 100 fb -1 of integrated luminosity. Additionally, insights related to a potential second EIC detector are documented, which could serve as a guidepost for future development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation-based Performance Analysis and Tuning for a Two-level Directly Connected System

Hardware and software co-design is becoming increasingly important due to complexities in supercomputing architectures. Simulating applications before there is access to the real hardware can assist machine architects in making better design decisions that can optimize application performance. At the same time, the application and runtime can be optimized and tuned beforehand. BigSim is a simulation-based performance prediction framework designed for these purposes. It can be used to perform packet-level network simulations of parallel applications using existing parallel machines. In this paper, we demonstrate the utility of BigSim in analyzing and optimizing parallel application performance for future systems based on the PERCS network. We present simulation studies using benchmarks and real applications expected to run on future supercomputers. Future petascale systems will have more than 100,000 cores, and we present simulations at that scale.

97 MATHEMATICS AND COMPUTING↗

Joint Management and Optimization of Residential Natural Gas and Electricity Distribution Networks Coupled via Fuel Cells

The interesting properties of natural gas as well as the growing electric power demand worldwide have led to increasing attention to natural-gas-based distributed generation applications in electric distribution systems. This paper goes over the interdependency between a residential natural gas network and an electric distribution network that are coupled via fuel cells. The modeling of the gas network is introduced first, and then the algorithm for gas flow study is presented. The optimal placement and sizing of fuel cell based distributed generation systems are formulated to minimize the losses in both the gas and electric distribution networks, subject to their model constraints. In addition to this, in order to capture the probabilistic nature of the optimization problem under study, the K-means clustering algorithm is applied to the gas and electricity demands to determine hourly load states and their corresponding probabilities. Furthermore, simulation studies are carried out on an integrated system consisting of the IEEE 69-bus distribution feeder and a radial 27-node natural gas network to verify the developed optimization model and the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling the Nonlinear Rheology of Polymer Additive Manufacturing

This report summarizes molecular and continuum simulation studies focused on developing physics - based predictive models for the evolution of polymer molecular order during the nonlinear processing flows of additive manufacturing. Our molecular simulations of polymer elongation flows identified novel mechanisms of fluid dissipation for various polymer architectures that might be harnessed to enhance material processability. In order to predict the complex thermal and flow history of polymer realistic additive manufacturing processes, we have developed and deployed a high - performance mesh - free hydrodynamics module in Sandia's LAMMPS software. This module called RHEO – short for Reproducing Hydrodynamics and Elastic Objects – hybridizes an updated - Lagrange reproducing - kernel method for complex fluids with a bonded particle method (BPM) to capture solidification and solid objects in multiphase flows. In combination, our two methods allow rapid, multiscale characterization of the hydrodynamics and molecular evolution of polymers in realistic processing geometries.

36 MATERIALS SCIENCE↗

Effect of shear on aircraft landing

A simulation study was conducted to determine the effect of wind shear on aircraft landings. The landing of various type of commercial and military aircraft was digitally simulated starting from an initial altitude of 300 feet. Assuming no pilot feedback during descent, the deviation in touchdown point due to vertical profiles of wind shear was determined. The vertical profiles of wind shear are defined in terms of surface roughness, Z sub 0, and stability, L, parameters. The effects on touchdown due to Z sub 0 and L have been calculated for the different type aircraft. Comparisons were made between the following types of aircraft: (1) C-130E, (2) C-135A, (3) C-141, (4) DC-8, (5) Boeing 747, and (6) an augmentor-wing STOL. In addition, the wind shear effect on touchdown resulting from different locations of the center of gravity and gross weights was also analyzed.

Luers, J. K.↗

Microwave holography of large reflector antennas - Simulation algorithms

The performance of large reflector antennas can be improved by identifying the location and amount of their surface distortions and correcting them. To determine the accuracy of the constructed surface profiles, simulation studies are used to incorporate both the effects of systematic and random distortions, particularly the effects of the displaced surface panels. In this paper, different simulation models are investigated, emphasizing a model based on the vector diffraction analysis of a curved reflector with displaced panels. The simulated far-field patterns are then used to reconstruct the location and amount of displacement of the surface panels by employing a fast Fourier transform/iterative procedure. The sensitivity of the microwave holography technique based on the number of far-field sampled points, level of distortions, polarizations, illumination tapers, etc., is also examined.

Rahmat-Samii, Y.↗

FaNGaS: a New Instrument for Fast Neutron Gamma Spectroscopy at FRM II Research Reactor at Garching

For the identification and quantification of actinides in radioactive packages, the non-destructive method of Prompt-Gamma Activation Analysis (PGAA) is applied. To investigate the inelastic (n, n 'γ) scattering, a new instrumentation was installed at the FRM II research reactor. It is designed to exploit the 10{sup 8} cm{sup -2}s{sup -1} neutrons at an average neutron energy of 1.9 MeV delivered by the SR10 beam line. The outgoing prompt γ-rays are measured utilizing a 50% efficiency HPGe detector. Since the cross sections are expected to be low for such a process, two related factors had to be taken into account for the design of the instrumentation: the high beam intensity at the sample position and the high signal-to-background ratio seen by the detector. Eventual low energy neutrons due to the multiple scatterings through the beam line can be minimized using collimators in the beam tube. This has also an effect to a prior neutrons and photons background reduction of the experimental environment. A higher efficiency of the counting can be achieved by the lowering of background at the detector. In this case, a heavy shielding for both neutrons and photons, is designed around the detector while optimizing the sample-detector distance. Monte-Carlo simulation studies were conducted to effectively design the fast neutron beam collimators and the detector shield. A detailed description of the setup characterization and results from simulations and experimental measurements will be discussed through this contribution. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Assessment of Carbonated Brine Injection as Low-risk Strategy for Geologic Carbon Storage

The main objective of this early-phase research was to evaluate the techno-economic feasibility and risk associated with combined brine and CO 2 storage in SWD wells using brine dissolution in the North Dakota portion of the Williston Basin. Three simulation studies were conducted to investigate: (1) CO 2 phases at different conditions, (2) wellbore compatibility, and (3) long-term storage fate in reservoir. (1) A simple reservoir model and injection simulations were created using data to represent the BEST (brine extraction and storage test) site, an operational SWD facility located near Watford City, North Dakota. The pressure evolution caused by CO 2 comingled in produced water injectate in a layer cake reservoir was then modeled while tracking aqueous CO 2 throughout the project. The salinity of the injection water, the salinity of the reservoir brine, and the amount of dissolved CO 2 comingled in the injection water were varied. (2) A wellbore corrosion model was performed using the CO 2 concentrations selected based on the reservoir modeling to examine the carbonated produced water impact on wellbore. (3) Reactive transport modeling was conducted with the optimal CO 2 concentration for this injection site to study the rock-fluid interactions and CO 2 fate in the reservoir. Results suggest that CO 2 dissolved in produced water can be injected without appreciably increasing subsurface pressure or leakage risks. Pressure buildup was found to vary with salinity but not with CO 2 mass fraction. Simulation results show that lower CO 2 percent mass fraction leads to a higher amount of CO 2 that can be dissolved at a higher injection salinity. Furthermore, the long-term goal of dissolution trapping in a traditional carbon storage project is accomplished from the start, mitigating risks associated with potential migration of buoyant CO 2 , so long as the reservoir pressure and temperature are used to determine the maximum mass fraction of the dissolved CO 2 .

54 ENVIRONMENTAL SCIENCES↗

Digital simulation of a communication link for Pioneer Saturn Uranus atmospheric entry probe, part 1

A digital simulation study is presented for a candidate modulator/demodulator design in an atmospheric scintillation environment with Doppler, Doppler rate, and signal attenuation typical of the conditions of an outer planet atmospheric probe. The simulation results indicate that the mean channel error rate with and without scintillation are similar to theoretical characterizations of the link. The simulation gives information for calculating other channel statistics and generates a quantized symbol stream on magnetic tape from which error correction decoding is analyzed. Results from the magnetic tape data analyses are also included. The receiver and bit synchronizer are modeled in the simulation at the level of hardware component parameters rather than at the loop equation level and individual hardware parameters are identified. The atmospheric scintillation amplitude and phase are modeled independently. Normal and log normal amplitude processes are studied. In each case the scintillations are low pass filtered. The receiver performance is given for a range of signal to noise ratios with and without the effects of scintillation. The performance is reviewed for critical reciever parameter variations.

Hinrichs, C. A.↗