Search NASA⌕ Search

SEARCH · Search NASA

Results for “spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

The digital mirror Langmuir probe: Field programmable gate array implementation of real-time Langmuir probe biasing

High bandwidth, high spatial resolution measurements of electron temperature, density, and plasma potential are valuable for resolving turbulence in the boundary plasma of tokamaks. While conventional Langmuir probes can provide such measurements, either their temporal or spatial resolution is limited: the former by the sweep rate necessary for obtaining I-V characteristics and the latter by the need to use multiple electrodes, as is the case in triple and double probe configurations. The Mirror Langmuir Probe (MLP) bias technique overcomes these limitations by rapidly switching the voltage on a single electrode cycling between three bias states, each dynamically optimized for the local plasma conditions. The MLP system on Alcator C-Mod used analog circuitry to perform this function, measuring Te, VF, and Isat at 1.1 MSPS. Recently, a new prototype digital MLP controller has been implemented on a Red Pitaya Field Programmable Gate Array (FPGA) board which reproduces the functionality of the original controller and performs all data acquisition. There is also the potential to provide the plasma parameters externally for use with feedback control systems. The use of FPGA technology means the system is readily customizable at a fraction of the development time and implementation cost. A second Red Pitaya was used to test the MLP by simulating the current response of a physical probe using C-Mod experimental measurements. This project is available as a git repository to facilitate extensibility (e.g., real-time control outputs and more voltage states) and scalability through collaboration.

47 OTHER INSTRUMENTATION↗

Measuring calcium content in plants using NEXAFS spectroscopy

Calcium is important for the growth and development of plants. It serves crucial functions in cell wall and cell membrane structure and serves as a secondary messenger in signaling pathways relevant to nutrient and immunity responses. Thus, measuring calcium levels in plants is important for studies of plant biology and for technology development in food, agriculture, energy, and forest industries. Often, calcium in plants has been measured through techniques such as atomic absorption spectrophotometry (AAS), inductively coupled plasma–mass spectrometry (ICP-MS), and electrophysiology. These techniques, however, require large sample sizes, chemical extraction of samples or have limited spatial resolution. Here, we used near-edge X-ray absorption fine structure (NEXAFS) spectroscopy at the calcium L- and K-edges to measure the calcium to carbon mass ratio with spatial resolution in plant samples without requiring chemical extraction or large sample sizes. We demonstrate that the integrated absorbance at the calcium L-edge and the edge jump in the fluorescence yield at the calcium K-edge can be used to quantify the calcium content as the calcium mass fraction, and validate this approach with onion epidermal peels and ICP-MS. We also used NEXAFS to estimate the calcium mass ratio in hypocotyls of a model plant, Arabidopsis thaliana , which has a cell wall composition that is similar to that of onion epidermal peels. These results show that NEXAFS spectroscopy performed at the calcium edge provides an approach to quantify calcium levels within plants, which is crucial for understanding plant physiology and advancing plant-based materials.

59 BASIC BIOLOGICAL SCIENCES↗

Acoustic Tomography of the Atmosphere: A Large-Eddy Simulation Sensitivity Study

Accurate measurement of atmospheric turbulent fluctuations is critical for understanding environmental dynamics and improving models in applications such as wind energy. Advanced remote sensing technologies are essential for capturing instantaneous velocity and temperature fluctuations. Acoustic tomography (AT) offers a promising approach that utilizes sound travel times between an array of transducers to reconstruct turbulence fields. This study presents a systematic evaluation of the time-dependent stochastic inversion (TDSI) algorithm for AT using synthetic travel-time measurements derived from large-eddy simulation (LES) fields under both neutral and convective atmospheric boundary-layer conditions. Unlike prior work that relied on field observations or idealized fields, the LES framework provides a ground-truth atmospheric state, enabling quantitative assessment of TDSI retrieval reliability, sensitivity to travel-time measurement noise, and dependence on covariance model parameters and temporal data integration. A detailed sensitivity analysis was conducted to determine the best-fit model parameters, identify the tolerance thresholds for parameter mismatch, and establish a maximum spatial resolution. The TDSI algorithm successfully reconstructed large-scale velocity and temperature fluctuations with root mean square errors ( RMSE s) below 0.35 m/s and 0.12 K, respectively. Spectral analysis established a maximum spatial resolution of approximately 1.4 m, and reconstructions remained robust for travel-time measurement uncertainties up to 0.002 s. These findings provide critical insights into the operational limits of TDSI and inform future applications of AT for atmospheric turbulence characterization and system design.

17 WIND ENERGY↗

The Digital Mirror Langmuir Probe: Field Programmable Gate Array Implementation of Real-Time Langmuir Probe Biasing

High bandwidth, high spatial resolution measurements of electron temperature, density and plasma potential are valuable for resolving turbulence in the boundary plasma of tokamaks. While conventional Langmuir probes can provide such measurements either their temporal or spatial resolution is limited: the former by the sweep rate necessary for obtaining I-V characteristics and the latter by the need to use multiple electrodes, as is the case in triple and double probe configurations. The Mirror Langmuir Probe (MLP) bias technique overcomes these limitations by rapidly switching the voltage on a single electrode cycling between three bias states, each dynamically optimised for the local plasma conditions. The MLP system on Alcator C-Mod used analog circuitry to perform this function, measuring Te, VF, and Isat at 1.1 MSPS. Recently, a new prototype digital MLP controller has been implemented on a Red Pitaya Field Programmable Gate Array (FPGA) board which reproduces the functionality of the original controller and performs all data acquisition. There is also the potential to provide the plasma parameters externally for use with feedback control systems. The use of FPGA technology means the system is readily customisable at a fraction of the development time and implementation cost. A second Red Pitaya was used to test the MLP by simulating the current response of a physical probe using C-Mod experimental measurements. This project is available as a git repository to facilitate extensibility (e.g. real-time control outputs, more voltage states) and scalability through collaboration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Detecting Early Warning Signals of Tree Mortality in Boreal North America Using Multiscale Satellite Data

Increasing tree mortality from global change drivers such as drought and biotic infestations is a widespread phenomenon, including in the boreal zone where climate changes and feedbacks to the Earth system are relatively large. Despite the importance for science and management communities, our ability to forecast tree mortality at landscape to continental scales is limited. However, two independent information streams have the potential to inform and improve mortality forecasts: repeat forest inventories and satellite remote sensing. Time series of tree-level growth patterns indicate that productivity declines and related temporal dynamics often precede mortality years to decades before death. Plot-level productivity, in turn, has been related to satellite-based indices such as the Normalized difference vegetation index (NDVI). Here we link these two data sources to show that early warning signals of mortality are evident in several NDVI-based metrics up to 24 years before death. We focus on two repeat forest inventories and three NDVI products across western boreal North America where productivity and mortality dynamics are influenced by periodic drought. These data sources capture a range of forest conditions and spatial resolution to highlight the sensitivity and limitations of our approach. Overall, results indicate potential to use satellite NDVI for early warning signals of mortality. Relationships are broadly consistent across inventories, species, and spatial resolutions, although the utility of coarse-scale imagery in the heterogeneous aspen parkland was limited. Longer-term NDVI data and annually remeasured sites with high mortality levels generate the strongest signals, although we still found robust relationships at sites remeasured at a typical 5 year frequency. The approach and relationships developed here can be used as a basis for improving forest mortality models and monitoring systems.

heat↗

Dynamic Moss Observed with Hi-C

The High‐resolution Coronal Imager (Hi‐C), flown on 11 July 2012, has revealed an unprecedented level of detail and substructure within the solar corona. Hi‐C imaged a large active region (AR11520) with 0.2‐0.3'' spatial resolution and 5.5s cadence over a 5 minute period. An additional dataset with a smaller FOV, the same resolution, but with a higher temporal cadence (1s) was also taken during the rocket flight. This dataset was centered on a large patch of 'moss' emission that initially seemed to show very little variability. Image processing revealed this region to be much more dynamic than first thought with numerous bright and dark features observed to appear, move and disappear over the 5 minute observation. Moss is thought to be emission from the upper transition region component of hot loops so studying its dynamics and the relation between the bright/dark features and underlying magnetic features is important to tie the interaction of the different atmospheric layers together. Hi‐C allows us to study the coronal emission of the moss at the smallest scales while data from SDO/AIA and HMI is used to give information on these structures at different heights/temperatures. Using the high temporal and spatial resolution of Hi‐C the observed moss features were tracked and the distribution of displacements, speeds, and sizes were measured. This allows us to comment on both the physical processes occurring within the dynamic moss and the scales at which these changes are occurring.

Alexander, Caroline↗

Exploring the Mineralogy of the Moon with M3

From the initial era or lunar exploration, we have learned that many processes active on the early Moon are common to most terrestrial planets, including the record of early and late impact bombardment. Since most major geologic activity ceased on the Moon approx. 3 Gy ago, the Moon's surface provides a record of the earliest era of terrestrial planet evolution. The type and composition of minerals that comprise a planetary surface are a direct result of the initial composition and subsequent thermal and physical processing. Lunar mineralogy seen today is thus a direct record of the early evolution of the lunar crust and subsequent geologic processes. Specifically, the distribution and concentration of specific minerals is closely tied to magma ocean products, lenses of intruded or remelted plutons, basaltic volcanism and fire-fountaining, and any process (e.g. cratering) that might redistribute or transform primary and secondary lunar crustal materials. The Moon Mineralogy Mapper (M3, or "m-cube") is a state-of-the-art imaging spectrometer that will fly on Chandrayaan-1, the Indian Space Research Organization (ISRO) mission to be launched late 2007 to early 2008. M3 is one of several foreign instruments chosen by ISRO to be flown on Chandrayaan-1 to complement the strong ISRO payload package. M3 was selected through a peer-review process as part of NASA s Discovery Program. It is under the oversight of PI Carle Pieters at Brown University and is being built by an experienced team at the Jet Propulsion Laboratory. Data analysis and calibration are carried out by a highly qualified and knowledgeable Science Team. To characterize diagnostic properties of lunar minerals, M3 acquires high spectral resolution reflectance data from 700 to 3000 nm (optional to 430 nm). M3 operates as a pushbroom spectrometer with a slit oriented orthogonal to the S/C orbital motion. Measurements are obtained simultaneously for 640 cross track spatial elements and 261 spectral elements. This translates to 70 m/pixel spatial resolution from a nominal 100 km polar orbit for Chandrayaan-1 . The primary science goal of M3 is to characterize and map lunar surface mineralogy in the context of its geologic evolution as outlined above. This translates into several sub-topics that focus on exploring the mineral character of the highland crust, characterizing the diversity basaltic volcanism, and identifying potential volatile concentrations near the poles. The primary exploration goal is to assess and map lunar mineral resources at high spatial resolution to support planning for future, targeted missions.

Pieters, C. M.↗

High-resolution imaging of rain systems with the advanced microwave precipitation radiometer

An advanced Microwave Precipitation Radiometer (AMPR) has been developed and flown in the NASA ER-2-high-altitude aircraft for imaging various atmospheric and surface processes, primarily the internal structure of rain clouds. The AMPR is a scanning four-frequency total power microwave radiometer that is externally calibrated with high-emissivity warm and cold loads. Separate antenna systems allow the sampling of the 10.7- and 19.35-GHz channels at the same spatial resolution, while the 37.1- and 85.5-GHz channels utilize the same multifrequency feedhorn as the 19.35-GHz channel. Spatial resolutions from an aircraft altitude of 20-km range from 0.6 km at 85.5 GHz to 2.8 km at 19.35 and 10.7 GHz. All channels are sampled every 0.6 km in both along-track and cross-track directions, leading to a contiguous sampling pattern of the 85.5-GHz 3-dB beamwidth footprints, 2.3X oversampling of the 37.1-GHz data, and 4.4X oversampling of the 19.35- and 10.7-GHz data. Radiometer temperature sensitivities range from 0.2 to 0.5 C. Details of the system are described, including two different calibration systems and their effect on the data collected. Examples of oceanic rain systems are presented from Florida and the tropical west Pacific that illustrate the wide variety of cloud water, rainwater, and precipitation-size ice combinations that are observable from aircraft altitudes.

Spencer, Roy W.↗

A New Hybrid Spatio-temporal Model for Estimating Daily Multi-year PM2.5 Concentrations Across Northeastern USA Using High Resolution Aerosol Optical Depth Data

The use of satellite-based aerosol optical depth (AOD) to estimate fine particulate matter PM(sub 2.5) for epidemiology studies has increased substantially over the past few years. These recent studies often report moderate predictive power, which can generate downward bias in effect estimates. In addition, AOD measurements have only moderate spatial resolution, and have substantial missing data. We make use of recent advances in MODIS satellite data processing algorithms (Multi-Angle Implementation of Atmospheric Correction (MAIAC), which allow us to use 1 km (versus currently available 10 km) resolution AOD data.We developed and cross validated models to predict daily PM(sub 2.5) at a 1X 1 km resolution across the northeastern USA (New England, New York and New Jersey) for the years 2003-2011, allowing us to better differentiate daily and long term exposure between urban, suburban, and rural areas. Additionally, we developed an approach that allows us to generate daily high-resolution 200 m localized predictions representing deviations from the area 1 X 1 km grid predictions. We used mixed models regressing PM(sub 2.5) measurements against day-specific random intercepts, and fixed and random AOD and temperature slopes. We then use generalized additive mixed models with spatial smoothing to generate grid cell predictions when AOD was missing. Finally, to get 200 m localized predictions, we regressed the residuals from the final model for each monitor against the local spatial and temporal variables at each monitoring site. Our model performance was excellent (mean out-of-sample R(sup 2) = 0.88). The spatial and temporal components of the out-of-sample results also presented very good fits to the withheld data (R(sup 2) = 0.87, R(sup)2 = 0.87). In addition, our results revealed very little bias in the predicted concentrations (Slope of predictions versus withheld observations = 0.99). Our daily model results show high predictive accuracy at high spatial resolutions and will be useful in reconstructing exposure histories for epidemiological studies across this region.

Air pollution↗

Interior soft x-ray tomography with sparse global sampling

To investigate the feasibility of interior imaging reconstruction in soft X-ray tomography for higher-resolution cellular imaging, including whole-cell imaging, we develop an alignment and reconstruction algorithm that combines a small number of sparse whole-cell images with a high-resolution local interior scan. Based on numerical simulations, we demonstrate that combined reconstructions mitigate the depth-of-field limitation in high-resolution scans, enable radiation dose optimization, and yield quantitative X-ray absorption values with sparse sampling. We further validate our numerical approach using experimental data from two different cell types and show that the combined reconstruction reliably provides high spatial resolution within an interior region of interest of a whole cell. The resulting sparse reconstruction framework offers robust, faithful visualization of cellular organelles in soft X-ray tomography. This mesoscale imaging strategy allows one to ‘scout’ and zoom into selected subcellular volumes of interest, enabling increased spatial resolution without sacrificing larger-volume imaging and providing information on the relative positions of all organelles within a cell.

3D imaging↗

Development of a novel neutron detection technique by using a boron layer coating a Charge Coupled Device

This article describes the design features and the first test measurements obtained during the installation of a novel high resolution 2D neutron detection technique. The technique proposed in this work consists of a boron layer (enriched in ${^{10}}$B) placed on a scientific Charge Coupled Device (CCD). After the nuclear reaction ${^{10}}$B(n,$\alpha$)${^{7}}$Li, the CCD detects the emitted charge particles thus obtaining information on the neutron absorption position. The above mentioned ionizing particles, with energies in the range 0.5-5.5 MeV, produce a plasma effect in the CCD which is recorded as a circular spot. This characteristic circular shape, as well as the relationship observed between the spot diameter and the charge collected, is used for the event recognition, allowing the discrimination of undesirable gamma events. We present the first results recently obtained with this technique, which has the potential to perform neutron tomography investigations with a spatial resolution better than that previously achieved. Numerical simulations indicate that the spatial resolution of this technique will be about 15 $\mu$m, and the intrinsic detection efficiency for thermal neutrons will be about 3 %. We compare the proposed technique with other neutron detection techniques and analyze its advantages and disadvantages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rare Earth Element Measurements of Melilite and Fassaite in Allende Cai by Nanosims

The rare earth elements (REEs) are concentrated in CAIs by approx. 20 times the chondritic average [e.g., 1]. The REEs in CAIs are important to understand processes of CAI formation including the role of volatilization, condensation, and fractional crystallization [1,2]. REE measurements are a well established application of ion microprobes [e.g., 3]. However the spatial resolution of REE measurements by ion microprobe (approx.20 m) is not adequate to resolve heterogeneous distributions of REEs among/within minerals. We have developed methods for measuring REE with the NanoSIMS 50L at smaller spatial scales. Here we present our initial measurements of REEs in melilite and fassaite in an Allende Type-A CAI with the JSC NanoSIMS 50L. We found that the key parameters for accurate REE abundance measurements differ between the NanoSIMS and conventional SIMS, in particular the oxide-to-element ratios, the relative sensitivity factors, the energy distributions, and requisite energy offset. Our REE abundance measurements of the 100 ppm REE diopside glass standards yielded good reproducibility and accuracy, 0.5-2.5 % and 5-25 %, respectively. We determined abundances and spatial distributions of REEs in core and rim within single crystals of fassaite, and adjacent melilite with 5-10 m spatial resolution. The REE abundances in fassaite core and rim are 20-100 times CI abundance but show a large negative Eu anomaly, exhibiting a well-defined Group III pattern. This is consistent with previous work [4]. On the other hand, adjacent melilite shows modified Group II pattern with no strong depletions of Eu and Yb, and no Tm positive anomaly. REE abundances (2-10 x CI) were lower than that of fassaite. These patterns suggest that fassaite crystallized first followed by a crystallization of melilite from the residual melt. In future work, we will carry out a correlated study of O and Mg isotopes and REEs of the CAI in order to better understand the nature and timescales of its formation process and subsequent metamorphic history.

Ito, M.↗

Dynamic Moss Observed with Hi-C

The High-resolution Coronal Imager (Hi-C), flown on 11 July 2012, has revealed an unprecedented level of detail and substructure within the solar corona. Hi-­‐C imaged a large active region (AR11520) with 0.2-0.3'' spatial resolution and 5.5s cadence over a 5 minute period. An additional dataset with a smaller FOV, the same resolution, but with a higher temporal cadence (1s) was also taken during the rocket flight. This dataset was centered on a large patch of 'moss' emission that initially seemed to show very little variability. Image processing revealed this region to be much more dynamic than first thought with numerous bright and dark features observed to appear, move and disappear over the 5 minute observation. Moss is thought to be emission from the upper transition region component of hot loops so studying its dynamics and the relation between the bright/dark features and underlying magnetic features is important to tie the interaction of the different atmospheric layers together. Hi-C allows us to study the coronal emission of the moss at the smallest scales while data from SDO/AIA and HMI is used to give information on these structures at different heights/temperatures. Using the high temporal and spatial resolution of Hi-C the observed moss features were tracked and the distribution of displacements, speeds, and sizes were measured. This allows us to comment on both the physical processes occurring within the dynamic moss and the scales at which these changes are occurring.

Alexander, Caroline↗

High-resolution mapping of nitrogen oxide emissions in large US cities from TROPOMI retrievals of tropospheric nitrogen dioxide columns

Satellite-derived spatiotemporal patterns of nitrogen oxide (NOx) emissions can improve accuracy of emission inventories to better support air quality and climate research and policy studies. In this study, we develop a new method by coupling the chemical transport Model-Independent SATellite-derived Emission estimation Algorithm for Mixed-sources (MISATEAM) with a divergence method to map high-resolution NO x emissions across US cities using TROPOspheric Monitoring Instrument (TROPOMI) tropospheric nitrogen dioxide (NO 2 ) retrievals. The accuracy of the coupled method is validated through application to synthetic NO 2 observations from the NASA-Unified Weather Research and Forecasting (NU-WRF) model, with a horizontal spatial resolution of 4 km × 4 km for 33 large and mid-size US cities. Validation reveals excellent agreement between inferred and NU-WRF-provided emission magnitudes (R= 0.99, normalized mean bias, NMB = —0.01) and a consistent spatial pattern when comparing emissions for individual grid cells (R = 0.88 ± 0.06). We then develop a TROPOMI-based database reporting annual emissions for 39 US cities at a horizontal spatial resolution of 0.05° × 0.05° from 2018 to 2021. This database demonstrates a strong correlation (R= 0.90) with the National Emission Inventory (NEI) but reveals some bias (NMB = —0.24). There are noticeable differences in the spatial patterns of emissions in some cities. Our analysis suggests that uncertainties in TROPOMI-based emissions and potential misallocation of emissions and/or missing sources in bottom-up emission inventories both contribute to these differences.

54 ENVIRONMENTAL SCIENCES↗

High-Resolution Mapping of Nitrogen Oxide Emissions in Large US Cities From TROPOMI Retrievals of Tropospheric Nitrogen Dioxide Columns

Satellite-derived spatiotemporal patterns of nitrogen oxide (NO x ) emissions can improve accuracy of emission inventories to better support air quality and climate research and policy studies. In this study, we develop a new method by coupling the chemical transport Model-Independent SATellite-derived Emission estimation Algorithm for Mixed-sources (MISATEAM) with a divergence method to map high-resolution NO x emissions across US cities using TROPOspheric Monitoring Instrument (TROPOMI) tropospheric nitrogen dioxide (NO 2 ) retrievals. The accuracy of the coupled method is validated through application to synthetic NO 2 observations from the NASA-Unified Weather Research and Forecasting (NU-WRF) model, with a horizontal spatial resolution of 4 km × 4 km for 33 large and mid-size US cities. Validation reveals excellent agreement between inferred and NU-WRF-provided emission magnitudes (R= 0.99, normalized mean bias, NMB = −0.01) and a consistent spatial pattern when comparing emissions for individual grid cells (R=0.88 ± 0.06). We then develop a TROPOMI-based database reporting annual emissions for 39 US cities at a horizontal spatial resolution of 0.05° × 0.05° from 2018 to 2021. This database demonstrates a strong correlation (R= 0.90) with the National Emission Inventory (NEI) but reveals some bias (NMB = −0.24). There are noticeable differences in the spatial patterns of emissions in some cities. Our analysis suggests that uncertainties in TROPOMI-based emissions and potential misallocation of emissions and/or missing sources in bottom-up emission inventories both contribute to these differences.

NOx emissions↗

Fast X-ray Nanotomography with Sub-10 nm Resolution as a Powerful Imaging Tool for Nanotechnology and Energy Storage Applications

In the last decade, transmission X-ray microscopes (TXMs) have come into operation in most of the synchrotrons worldwide. They have proven to be outstanding tools for non-invasive ex and in situ 3D characterization of materials at the nanoscale across varying range of scientific applications. However, their spatial resolution has not improved in many years, while newly developed functional materials and microdevices with enhanced performances exhibit nanostructures always finer. Here, optomechanical breakthroughs leading to fast 3D tomographic acquisitions (85 min) with sub-10 nm spatial resolution, narrowing the gap between X-ray and electron microscopy, are reported. These new achievements are first validated with 3D characterizations of nanolithography objects corresponding to ultrahigh-aspect-ratio hard X-ray zone plates. Then, this powerful technique is used to investigate the morphology and conformality of nanometer-thick film electrodes synthesized by atomic layer deposition and magnetron sputtering deposition methods on 3D silicon scaffolds for electrochemical energy storage applications.

36 MATERIALS SCIENCE↗

Bremsstrahlung x-ray generation for high optical depth radiography applications on the National Ignition Facility [Bremsstrahlung x-ray generation for opacity radiography applications on the National Ignition Facility]

Here, we have tested a set of x-ray sources for use as probes of highly attenuating, laser-driven experiments on the National Ignition Facility (NIF). Unlike traditional x-ray sources that optimize for a characteristic atomic transition (often the n = 2 → n = 1 transition in ionized, He-like atoms), the design presented here maximizes the total photon flux by optimizing for intense, broadband Bremsstrahlung radiation. Three experiments were performed with identical targets, including a uranium x-ray source foil and a tungsten substrate with a narrow (25 μm wide) collimating slit to produce a quasi-1D x-ray source. Two experiments were performed using 12 beams from the NIF laser, each delivering approximately 46 kJ of laser energy but with different laser spatial profiles. This pair yielded similar temporal x-ray emission profiles, spatial resolution, and inferred hot electron temperature. A third experiment with only 6 beams delivering approximately 25 kJ produced a lower hot electron temperature and significantly lower x-ray flux, as well as poorer spatial resolution. The data suggest that laser pointing jitter may have affected the location and intensity of the emitting plasma, producing an emission volume that was not well centered behind the collimating slit and lower intensity than designed. However, the 12-beam design permits x-ray radiography through highly attenuating samples, where lower energy line-emission x-ray sources would be nearly completely attenuated.

47 OTHER INSTRUMENTATION↗

High Fidelity Tomographic Density Reconstructions [Slides]

Pressed high explosives have small density variations associated with the pressing process, from a few to sub percent depending on the material. Variations at these levels are known to have an impact on HE performance. Currently, a destructive testing method based on physical sectioning followed by immersion density measurements (slice and dice) is utilized. However, this method has poor spatial resolution limited by the the sectioning size, 1-2 cm. If possible, radiographic methods including Computed Tomography (CT) would be preferred, as they are non-destructive and have higher (less than .1 mm) spatial resolution. However, beam hardening, scattered radiation, and detector effects make density reconstructions at this level extremely challenging.

42 ENGINEERING↗