Search NASA⌕ Search

SEARCH · Search NASA

Results for “statistical processing methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Component separation of a isotropic Gravitational Wave Background

A Gravitational Wave Background (GWB) is expected in the universe from the superposition of a large number of unresolved astrophysical sources and phenomena in the early universe. Each component of the background (e.g., from primordial metric perturbations, binary neutron stars, milli-second pulsars etc.) has its own spectral shape. Many ongoing experiments aim to probe GWB at a variety of frequency bands. In the last two decades, using data from ground-based laser interferometric gravitational wave (GW) observatories, upper limits on GWB were placed in the frequency range of 0∼ 50−100 Hz, considering one spectral shape at a time. However, one strong component can significantly enhance the estimated strength of another component. Hence, estimation of the amplitudes of the components with different spectral shapes should be done jointly. Here we propose a method for 'component separation' of a statistically isotropic background, that can, for the first time, jointly estimate the amplitudes of many components and place upper limits. The method is rather straightforward and needs negligible amount of computation. It utilises the linear relationship between the measurements and the amplitudes of the actual components, alleviating the need for a sampling based method, e.g., Markov Chain Monte Carlo (MCMC) or matched filtering, which are computationally intensive and cumbersome in a multi-dimensional parameter space. Using this formalism we could also study how many independent components can be separated using a given dataset from a network of current and upcoming ground based interferometric detectors.

79 ASTRONOMY AND ASTROPHYSICS↗

Inverse Uncertainty Quantification of Reactor Simulation with Polynomial Chaos Surrogate Model

Reliable uncertainty quantification (UQ) and sensitivity analysis (SA) is significant part of modelling and simulation. This is particularly important in the nuclear community due to the fact that the licensing of nuclear installations has shifted from conservative to Best Estimate plus Uncertainty (BEPU) methodologies. UQ can be broadly classified as forward UQ and inverse UQ. Forward UQ is the process of quantifying the uncertainties in simulation outputs by propagating the uncertainties in input parameters. It requires knowledge in the input uncertainty, which is often specified by ad-hoc expert judgment which lacks mathematical rigor. The inverse UQ is the process to determine the uncertainty in input parameters given observations of the output. The purpose of this paper is to replace such ad-hoc expert judgment of the statistical properties of input model parameters in nuclear reactor simulation. This summary presents work on inverse UQ of a nonlinear Point Reactor Kinetics Equations - lumped thermal-hydraulics parameter coupled problem. Bayesian inference and Markov Chain Monte Carlo (MCMC) are used for the inverse UQ. Because MCMC requires a large number of simulations which is impractical for models that are computationally expensive, surrogate models is constructed by generalized Polynomial Chaos (PC) expansion technique. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Technical Note: Potential errors in optical density measurements due to scanning side in EBT and EBT2 Gafchromic film dosimetry

Purpose: The purpose of this study is to determine the effect on the measured optical density of scanning on either side of a Gafchromic EBT and EBT2 film using an Epson (Epson Canada Ltd., Toronto, Ontario) 10000XL flat bed scanner. Methods: Calibration curves were constructed using EBT2 film scanned in landscape orientation in both reflection and transmission mode on an Epson 10000XL scanner. Calibration curves were also constructed using EBT film. Potential errors due to an optical density difference from scanning the film on either side (''face up'' or ''face down'') were simulated. Results: Scanning the film face up or face down on the scanner bed while keeping the film angular orientation constant affects the measured optical density when scanning in reflection mode. In contrast, no statistically significant effect was seen when scanning in transmission mode. This effect can significantly affect relative and absolute dose measurements. As an application example, the authors demonstrate potential errors of 17.8% by inverting the film scanning side on the gamma index for 3%--3 mm criteria on a head and neck intensity modulated radiotherapy plan, and errors in absolute dose measurements ranging from 10% to 35% between 2 and 5 Gy. Conclusions: Process consistency is the key to obtaining accurate and precise results in Gafchromic film dosimetry. When scanning in reflection mode, care must be taken to place the film consistently on the same side on the scanner bed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-474: IMRT Verification Using the On-Board EPID

Purpose: To verify IMRT and Rapid Arc (RA) plan's agreement with treatment delivery for radiation therapy using an on-board EPID compared to MapCHECK2 and ArcCHECK. Methods: On-board EPID (Exact arm) is commissioned using manufacturer's Preconfigured Data Input Package (PDIP). Portal dose calculation engine for comparison with measurement was commissioned with PDIP. The absolute dosimetric calibration of the EPID is performed using 10×10cm field size at 105cm source to image detector distance with 90.7 CU in the integrated mode. The dark and flood field of EPID were also calibrated in the integrated mode for all energies and dose rates. The output dose-response data from the manufacturer was verified. The improved gamma test method was used for EPID data analysis. Gamma test were used for MapCHECK2 (or ArcCHECK). The sensitivity of the method was tested using collimator rotation at 3 degree and 5 degree. Student T-test was used to distinguish the difference among the groups. Results: IMRT: The average of Gamma passing rate using EPID and MapCHECK2 is 98.9±1.6% and 98.7±2.0% (p = 0.342). There is no statistical difference between two groups.RA: The average of Gamma passing rate using EPID and ArcCHECK is 97.2±2.3% and 93.2±4.1%. (p = 0.002). EPID significantly improved the RapidARC plan passing rate compared to the ArcCHECK. 5% dose change typically causes between 3 – 55% change in Gamma. Conclusion: Using the EPID, we were able to perform QA verification on IMRT plans comparable to MapCHECK2 (p=0.342) and superior to that of ArcCHECK (p=0.002) using Gamma 3%, 3mm criteria. The sensitivity of EPID was found to be comparable to that of the MapCHECK2 and ArcCHECK. EPID dosimetry is faster (4.3 mins vs. 10 mins) due to easier setup and integrated data processing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

FAST CALCULATION OF THE LOMB-SCARGLE PERIODOGRAM USING GRAPHICS PROCESSING UNITS

I introduce a new code for fast calculation of the Lomb-Scargle periodogram that leverages the computing power of graphics processing units (GPUs). After establishing a background to the newly emergent field of GPU computing, I discuss the code design and narrate key parts of its source. Benchmarking calculations indicate no significant differences in accuracy compared to an equivalent CPU-based code. However, the differences in performance are pronounced; running on a low-end GPU, the code can match eight CPU cores, and on a high-end GPU it is faster by a factor approaching 30. Applications of the code include analysis of long photometric time series obtained by ongoing satellite missions and upcoming ground-based monitoring facilities, and Monte Carlo simulation of periodogram statistical properties.

79 ASTRONOMY AND ASTROPHYSICS↗

Scientific discovery in a model-centric framework: Reproducibility, innovation, and epistemic diversity

Consistent confirmations obtained independently of each other lend credibility to a scientific result. We refer to results satisfying this consistency as reproducible and assume that reproducibility is a desirable property of scientific discovery. Yet seemingly science also progresses despite irreproducible results, indicating that the relationship between reproducibility and other desirable properties of scientific discovery is not well understood. These properties include early discovery of truth, persistence on truth once it is discovered, and time spent on truth in a long-term scientific inquiry. We build a mathematical model of scientific discovery that presents a viable framework to study its desirable properties including reproducibility. In this framework, we assume that scientists adopt a model-centric approach to discover the true model generating data in a stochastic process of scientific discovery. We analyze the properties of this process using Markov chain theory, Monte Carlo methods, and agent-based modeling. We show that the scientific process may not converge to truth even if scientific results are reproducible and that irreproducible results do not necessarily imply untrue results. The proportion of different research strategies represented in the scientific population, scientists’ choice of methodology, the complexity of truth, and the strength of signal contribute to this counter-intuitive finding. Important insights include that innovative research speeds up the discovery of scientific truth by facilitating the exploration of model space and epistemic diversity optimizes across desirable properties of scientific discovery.

97 MATHEMATICS AND COMPUTING↗

Implementation of Feldman-Cousins Corrections and Oscillation Calculations in the HPC Environment for the NOvA Experiment

Analysis of neutrino oscillation data involves a combination of complex fitting procedures and statistical correction techniques that are used to determine the full three-flavor PMNS parameters and constraint contours. These techniques rely on computationally intensive “multi-universe” stochastic modeling. The process of calculating these contours and corrections can dominate final stages of the data analysis and become a bottleneck for examining the ef-fect of systematic variations on the final results. As part of the DOE SciDAC-4 sponsored research program, we present a new implementation of a neutrino oscillation fitting and framework to carry out calculations of Feldman-Cousins corrections. This implementation is specifically designed and optimized to operate on modern High-Performance Computing (HPC) facilities. We present the performance of the system in calculating allowed regions for the NOvA experiment based on 8.9 x 1020 and 6.9 x 1020 protons-on-target (POT) neutrino and antineutrino datasets, and compare the performance of this new implementation run at the NERSC supercomputing facility with that from methods used previously by the NOvA collaboration running on grid computing facilities.

Sousa, Alexandre↗

A Bayesian view of the current status of dark matter direct searches

Bayesian statistical methods offer a simple and consistent framework for incorporating uncertainties into a multi-parameter inference problem. In this work we apply these methods to a selection of current direct dark matter searches. We consider the simplest scenario of spin-independent elastic WIMP scattering, and infer the WIMP mass and cross-section from the experimental data with the essential systematic uncertainties folded into the analysis. We find that when uncertainties in the scintillation efficiency of XENON100 have been accounted for, the resulting exclusion limit is not sufficiently constraining to rule out the CoGeNT preferred parameter region, contrary to previous claims. In the same vein, we also investigate the impact of astrophysical uncertainties on the preferred WIMP parameters. We find that within the class of smooth and isotropic WIMP velocity distributions, it is difficult to reconcile the DAMA and the CoGeNT preferred regions by tweaking the astrophysics parameters alone. If we demand compatibility between these experiments, then the inference process naturally concludes that a high value for the sodium quenching factor for DAMA is preferred.

79 ASTRONOMY AND ASTROPHYSICS↗

Combining Machine Learning and Comparative Effectiveness Methodology to Study Primary Care Pharmacotherapy Pathways for Veterans With Depression

Our objective is to demonstrate an innovative method combining machine learning with comparative effectiveness research techniques and to investigate a hitherto unstudied question about the effectiveness of common prescribing patterns. For Operation Enduring Freedom/Operation Iraqi Freedom veterans with major depressive disorder, we generate pharmacotherapy pathways (of antidepressants) using process mining and machine learning. We select the medication episodes that were started at subtherapeutic doses by the first assigned primary care physician and observe the paths that those medication episodes follow. Using 2-stage least squares, we test the effectiveness of starting at a low dose and staying low for longer versus ramping up fast while balancing observable and unobservable characteristics of patients and providers through instrumental variables. We leverage predetermined provider practice patterns as instruments. We collected outpatient pharmacy data for selective serotonin reuptake inhibitors and selective norepinephrine reuptake inhibitors, patient and provider characteristics (as control variables), and the instruments for our cohort. All data were extracted for the period between 2006 and 2020. There is a statistically significant positive effect (0.68, 95% CI 0.11–1.25) of “ramping up fast” on engagement in care. When we examine the effect of “ramping up slow”, we see an insignificant negative impact on engagement in care (−0.82, 95% CI −1.89 to 0.25). As expected, the probability of drop-out also seems to have a negative effect on engagement in care (−0.39, 95% CI −0.94 to 0.17). We further validate these results by testing with medication possession ratios calculated periodically as an alternative engagement in care metric. Our findings contradict the “Start low, go slow” adage, indicating that ramping up the dose of an antidepressant faster has a significantly positive effect on engagement in care for our population.

60 APPLIED LIFE SCIENCES↗

Higher Compact Multiple Occurrence around Metal-poor M-dwarfs and Late-K-dwarfs

The planet–metallicity correlation serves as a potential link between exoplanet systems as we observe them today and the effects of bulk composition on the planet formation process. Many observers have noted a tendency for Jovian planets to form around stars with higher metallicities; however, there is no consensus on a trend for smaller planets. Here, we investigate the planet–metallicity correlation for rocky planets in single- and multi-planet systems around Kepler M-dwarf and late-K-dwarf stars. Due to molecular blanketing and the dim nature of these low-mass stars, it is difficult to make direct elemental abundance measurements via spectroscopy. We instead use a combination of accurate and uniformly measured parallaxes and photometry to obtain relative metallicities and validate this method with a subsample of spectroscopically determined metallicities. We use the Kolmogorov–Smirnov (K-S) test, Mann–Whitney U-test, and Anderson–Darling (AD) test to compare the compact multiple planetary systems with single-transiting planet systems and systems with no detected transiting planets. We find that the compact multiple planetary systems are derived from a statistically more metal-poor population, with a p-value of 0.015 in the K-S test, a p-value of 0.005 in the Mann–Whitney U-test, and a value of 2.574 in the AD test statistic, which exceeds the derived threshold for significance by a factor of 25. We conclude that metallicity plays a significant role in determining the architecture of rocky planet systems. Compact multiples either form more readily, or are more likely to survive on gigayear timescales, around metal-poor stars.

47 OTHER INSTRUMENTATION↗

TH-AB-202-04: Auto-Adaptive Margin Generation for MLC-Tracked Radiotherapy

Purpose: To develop an auto-adaptive margin generator for MLC tracking. The generator is able to estimate errors arising in image guided radiotherapy, particularly on an MR-Linac, which depend on the latencies of machine and image processing, as well as on patient motion characteristics. From the estimated error distribution, a segment margin is generated, able to compensate errors up to a user-defined confidence. Method: In every tracking control cycle (TCC, 40ms), the desired aperture D(t) is compared to the actual aperture A(t), a delayed and imperfect representation of D(t). Thus an error e(t)=A(T)-D(T) is measured every TCC. Applying kernel-density-estimation (KDE), the cumulative distribution (CDF) of e(t) is estimated. With CDF-confidence limits, upper and lower error limits are extracted for motion axes along and perpendicular leaf-travel direction and applied as margins. To test the dosimetric impact, two representative motion traces were extracted from fast liver-MRI (10Hz). The traces were applied onto a 4D-motion platform and continuously tracked by an Elekta Agility 160 MLC using an artificially imposed tracking delay. Gafchromic film was used to detect dose exposition for static, tracked, and error-compensated tracking cases. The margin generator was parameterized to cover 90% of all tracking errors. Dosimetric impact was rated by calculating the ratio between underexposed points (>5% underdosage) to the total number of points inside FWHM of static exposure. Results: Without imposing adaptive margins, tracking experiments showed a ratio of underexposed points of 17.5% and 14.3% for two motion cases with imaging delays of 200ms and 300ms, respectively. Activating the margin generated yielded total suppression (<1%) of underdosed points. Conclusion: We showed that auto-adaptive error compensation using machine error statistics is possible for MLC tracking. The error compensation margins are calculated on-line, without the need of assuming motion or machine models. Further strategies to reduce consequential overdosages are currently under investigation. This work was funded by the SoRTS consortium, which includes the industry partners Elekta, Philips and Technolution.

60 APPLIED LIFE SCIENCES↗

Dedicated breast CT: Fibroglandular volume measurements in a diagnostic population

Purpose: To determine the mean and range of volumetric glandular fraction (VGF) of the breast in a diagnostic population using a high-resolution flat-panel cone-beam dedicated breast CT system. This information is important for Monte Carlo-based estimation of normalized glandular dose coefficients and for investigating the dependence of VGF on breast dimensions, race, and pathology. Methods: Image data from a clinical trial investigating the role of dedicated breast CT that enrolled 150 women were retrospectively analyzed to determine the VGF. The study was conducted in adherence to a protocol approved by the institutional human subjects review boards and written informed consent was obtained from all study participants. All participants in the study were assigned BI-RADS{sup Registered-Sign} 4 or 5 as per the American College of Radiology assessment categories after standard diagnostic work-up and underwent dedicated breast CT exam prior to biopsy. A Gaussian-kernel based fuzzy c-means algorithm was used to partition the breast CT images into adipose and fibroglandular tissue after segmenting the skin. Upon determination of the accuracy of the algorithm with a phantom, it was applied to 137 breast CT volumes from 136 women. VGF was determined for each breast and the mean and range were determined. Pathology results with classification as benign, malignant, and hyperplasia were available for 132 women, and were used to investigate if the distributions of VGF varied with pathology. Results: The algorithm was accurate to within {+-}1.9% in determining the volume of an irregular shaped phantom. The study mean ({+-} inter-breast SD) for the VGF was 0.172 {+-} 0.142 (range: 0.012-0.719). VGF was found to be negatively correlated with age, breast dimensions (chest-wall to nipple length, pectoralis to nipple length, and effective diameter at chest-wall), and total breast volume, and positively correlated with fibroglandular volume. Based on pathology, pairwise statistical analysis (Mann-Whitney test) indicated that at the 0.05 significance level, there was no significant difference in distributions of VGF without adjustment for age between malignant and nonmalignant breasts (p= 0.41). Pairwise comparisons of the distributions of VGF in increasing order of mammographic breast density indicated all comparisons were statistically significant (p < 0.002). Conclusions: This study used a different clinical prototype breast CT system than that in previous studies to image subjects from a different geographical region, and used a different algorithm for analysis of image data. The mean VGF estimated from this study is within the range reported in previous studies, indicating that the choice of 50% glandular weight fraction to represent an average breast for Monte Carlo-based estimation of normalized glandular dose coefficients in mammography needs revising. In the study, the distributions of VGF did not differ significantly with pathology.

60 APPLIED LIFE SCIENCES↗

Cross sections for the formation of Rb84m,g, Rb83, and Rb82m in Sr86(d,x) reactions up to deuteron energies of 49 MeV: Competition between α-particle and multinucleon emission processes

Cross sections of Sr86(d,x) reactions leading to the products Rb84m,g, Rb83, and Rb82m were measured by the stacked-sample activation technique up to deuteron energies of 49 MeV. Nuclear model calculations were performed using the codes talys and empire, which combine the statistical, precompound, and direct interaction components. In all cases, the empire results were much higher than the talys calculation. Fairly good agreement was obtained between measured data and the talys calculation after some optimization of the input model parameters. Insight into competition between α-particle and multinucleon emission in the Y88 compound-nucleus system was also gained.

59 ≤ A ≤ 89↗

Robust methods for automatic image-to-world registration in cone-beam CT interventional guidance

Purpose: Real-time surgical navigation relies on accurate image-to-world registration to align the coordinate systems of the image and patient. Conventional manual registration can present a workflow bottleneck and is prone to manual error and intraoperator variability. This work reports alternative means of automatic image-to-world registration, each method involving an automatic registration marker (ARM) used in conjunction with C-arm cone-beam CT (CBCT). The first involves a Known-Model registration method in which the ARM is a predefined tool, and the second is a Free-Form method in which the ARM is freely configurable. Methods: Studies were performed using a prototype C-arm for CBCT and a surgical tracking system. A simple ARM was designed with markers comprising a tungsten sphere within infrared reflectors to permit detection of markers in both x-ray projections and by an infrared tracker. The Known-Model method exercised a predefined specification of the ARM in combination with 3D-2D registration to estimate the transformation that yields the optimal match between forward projection of the ARM and the measured projection images. The Free-Form method localizes markers individually in projection data by a robust Hough transform approach extended from previous work, backprojected to 3D image coordinates based on C-arm geometric calibration. Image-domain point sets were transformed to world coordinates by rigid-body point-based registration. The robustness and registration accuracy of each method was tested in comparison to manual registration across a range of body sites (head, thorax, and abdomen) of interest in CBCT-guided surgery, including cases with interventional tools in the radiographic scene. Results: The automatic methods exhibited similar target registration error (TRE) and were comparable or superior to manual registration for placement of the ARM within {approx}200 mm of C-arm isocenter. Marker localization in projection data was robust across all anatomical sites, including challenging scenarios involving the presence of interventional tools. The reprojection error of marker localization was independent of the distance of the ARM from isocenter, and the overall TRE was dominated by the configuration of individual fiducials and distance from the target as predicted by theory. The median TRE increased with greater ARM-to-isocenter distance (e.g., for the Free-Form method, TRE increasing from 0.78 mm to 2.04 mm at distances of {approx}75 mm and 370 mm, respectively). The median TRE within {approx}200 mm distance was consistently lower than that of the manual method (TRE = 0.82 mm). Registration performance was independent of anatomical site (head, thorax, and abdomen). The Free-Form method demonstrated a statistically significant improvement (p= 0.0044) in reproducibility compared to manual registration (0.22 mm versus 0.30 mm, respectively). Conclusions: Automatic image-to-world registration methods demonstrate the potential for improved accuracy, reproducibility, and workflow in CBCT-guided procedures. A Free-Form method was shown to exhibit robustness against anatomical site, with comparable or improved TRE compared to manual registration. It was also comparable or superior in performance to a Known-Model method in which the ARM configuration is specified as a predefined tool, thereby allowing configuration of fiducials on the fly or attachment to the patient.

60 APPLIED LIFE SCIENCES↗

Development and Demonstration of a Method to Evaluate Bio-Sampling Strategies Using Building Simulation and Sample Planning Software

In an effort to validate and demonstrate response and recovery sampling approaches and technologies, the U.S. Department of Homeland Security (DHS), along with several other agencies, have simulated a biothreat agent release within a facility at Idaho National Laboratory (INL) on two separate occasions in the fall of 2007 [1] and the fall of 2008. Because these events constitute only two realizations of many possible scenarios, increased understanding of sampling strategies can be obtained by virtually examining a wide variety of release and dispersion scenarios using computer simulations. This research effort demonstrates the use of two software tools, CONTAM [2], developed by the National Institute of Standards and Technology (NIST), and Visual Sample Plan (VSP), developed by Pacific Northwest National Laboratory (PNNL) [3]. CONTAM is a computer program that is used to simulate building airflow and contaminant transport on a whole-building scale. VSP is a software tool that employs statistically defensible approaches in developing sampling designs and analyzing data. CONTAM and VSP were used to 1) virtually examine a wide range of biological contaminant release and dispersion scenarios at the INL facility and 2) develop a process for creating and evaluating sampling strategies for a given scenario. The CONTAM modeling software was used to virtually contaminate a model of the INL test building under various release and dissemination scenarios. Simulations were based on a range of building design and operation parameters, thereby providing information not constrained by experimental parameters as in the real-world testing. The results of these numerous CONTAM simulations were then used to investigate the relevance and performance of various sampling strategies using VSP.

99 GENERAL AND MISCELLANEOUS↗

Processing and Thermoelectric Properties of TiNiSn Materials: A Review

The half-Heusler alloy TiNiSn is a promising material for high-temperature thermoelectric applications due to its good thermal stability and semiconductor-like electrical properties. Numerous synthesis techniques have been utilized to make TiNiSn, but a comparative study on its thermoelectric properties with respect to processing parameters has not been reported. Based on published experimental data, primary melting methods, such as arc melting or induction levitation melting, do not have a noticeable effect on the final thermoelectric properties, although choice of densification technique and annealing parameters correlate with each thermoelectric property. Thermal conductivity (2.47-6.08 W/m K), governed by lattice scattering effects, was maximized with high density from the spark plasma sintering (SPS) technique as well with low inclusions of metallic impurities and interstitial Ni defects from low-temperature, non-densified processes. Electrical resistivity (4.75-30 µΩ m), inversely related to thermal conductivity, is minimized when density is maximized and chemical defects are favorable from using SPS. All reported TiNiSn alloys contain intermetallic impurities, imparting a global trend of lowered electrical resistivity. Seebeck coefficient (− 273.20 to − 50.71 µV/K), proportional to electrical resistivity, is maximized when charge carrier concentration is minimized by eliminating phase impurities and Ni defects. Porosity has been observed to scatter low-energy electrons, which can increase Seebeck coefficient and electrical resistivity, although no statistical significance is found. An ideal TiNiSn alloy should have intermediate values of all interconnected thermoelectric properties to maximize ZT. Future research work should strive to include quantitative phase analysis to better characterize the contributions of Ni defects and impurity phases toward thermoelectric properties.

36 MATERIALS SCIENCE↗

Predicting surface deformation during mechanical attrition of metallic alloys

Extensive efforts have been devoted in both the engineering and scientific domains to seek new designs and processing techniques capable of making stronger and tougher materials. One such method for enhancing such damage-tolerance in metallic alloys is a surface nano-crystallization technology that involves the use of hundreds of small hard balls which are vibrated using high-power ultrasound so that they impact onto the surface of a material at high speed (termed Surface Mechanical Attrition Treatment or SMAT). However, few studies have been devoted to the precise underlying mechanical mechanisms associated with this technology and the effect of processing parameters. As SMAT is dynamic plastic deformation process, here we use random impact deformation as a means to investigate the relationship between impact deformation and the parameters involved in the processing, specifically ball size, impact velocity, ball density and kinetic energy. Using analytical and numerical solutions, we examine the size of the indents and the depths of the associated plastic zones induced by random impacts, with results verified by experiment in austenitic stainless steels. In addition, global random impact and local impact frequency models are developed to analyze the statistical characteristics of random impact coverage, together with a description of the effect of random multiple impacts, which are more reflective of SMAT. We believe that these models will serve as a necessary foundation for further, and more energy-efficient, development of such surface nano-crystalline processing technologies for the strengthening of metallic materials.

36 MATERIALS SCIENCE↗

MAGNETO-CONVECTION AND LITHIUM AGE ESTIMATES OF THE {beta} PICTORIS MOVING GROUP

Although the means of the ages of stars in young groups determined from Li depletion often agree with mean ages determined from Hertzsprung-Russell (H-R) diagram isochrones, there are often statistically significant differences in the ages of individual stars determined by the two methods. We find that inclusion of the effects of inhibition of convection due to the presence of magnetic fields leads to consistent ages for the individual stars. We illustrate how age consistency arises by applying our results to the {beta} Pictoris moving group (BPMG). We find that, although magnetic inhibition of convection leads to increased ages from the H-R diagram isochrones for all stars, Li ages are decreased for fully convective M stars and increased for stars with radiative cores. Our consistent age determination for BPMG of 40 Myr is larger than previous determinations by a factor of about two. We have also considered models in which the mixing length ratio is adjusted to give consistent ages. We find that our magneto-convection models, which give quantitative estimates of magnetic field strength, provide a viable alternative to models in which the effects of magnetic fields (and other processes) are accounted for by reducing the mixing length ratio.

79 ASTRONOMY AND ASTROPHYSICS↗