Search NASA⌕ Search

SEARCH · Search NASA

Results for “surface instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Primary cosmic rays on the lunar surface

Results are reported for determination of the galactic cosmic ray flux during various time intervals in the 1965-1972 period, on the basis of data from the instruments of a spacecraft that made a soft landing on the lunar surface, and from the radioactivity of samples returned by the spacecraft. During minimum solar activity (the second half of 1965 and the beginning of 1966) I sub 0 (E greater than or equal to 30 percent MeV/nucleon) was determined to be 0.43 (plus or minus 10 percent). These values, within the error limits of the determinations, agree with the corresponding values of galactic cosmic ray intensities determined by stratospheric measurements. The mean flux of galactic cosmic rays over the past million years is equal to I (E greater or equal to 100 MeV/nucleon) + 0.28 (plus or minus 20 percent). This value agrees with the mean flux of modulated cosmic rays during the period of the nineteenth solar cycle. The mean flux of solar protons between 1965 and 1972 was 2.46.

Vernov, S. N.↗

Recent Results in ICESat Geolocation Parameter Calibration from Range Residual Analysis

The Ice, Cloud and land Elevation Satellite (ICESat), launched on January 12, 2003, carries the Geoscience Laser Altimeter System (GLAS), which has a primary measurement of short-pulse laser-ranging to the Earths surface at 1064 nm wavelength at a rate of 40 pulses per second. The instrument has collected (at the time of this writing) over 540 million observations of the Earth's surface including precise elevation measurements of the ice sheets, sea ice roughness and thickness, ocean and land surface elevations and surface reflectivity. The accurate geolocation of GLASs surface returns, the spots from which the laser energy reflects on the Earths surface, is a critical issue in the scientific application of these data. Pointing, ranging, timing and orbit errors must be compensated to accurately geolocate the laser altimeter surface returns. Towards this end, the laser range observations can be fully exploited in an integrated residual analysis to accurately calibrate these geolocation/instrument parameters. The ICESat laser altimeter data have been simultaneously processed as direct altimetry from ocean sweeps and around-the-world scans along with dynamic crossovers in order to calibrate pointing ranging and timing. The analysis has resolved complex time varying signal resulting from thermal variations of instrument pointing and boresite shadowing. The calibration methodology and current calibration results are discussed along with future efforts and current geolocation accuracies.

Luthcke, Scott B.↗

Combined backscatter Moessbauer spectrometer/x ray fluorescence analyzer (BaMS/XRF) for extraterrestrial surfaces

We have designed and tested a prototype combined backscatter Moessbauer spectrometer and x-ray fluorescence analyzer (BaMS/XRF). A space qualified instrument based on this design would be suitable for in-situ use on planetary missions to the surfaces of the Moon (Artemis and lunar outpost), Mars (MESUR), asteroids, or other solid solar system objects. The BaMS/XRF instrument is designed to be capable of concurrent sample analyses for the mineralogy of iron-bearing phases and elemental composition without the need for sample preparation.

Shelfer, T. D.↗

The QCECOR Value-Added Product: Quality-Controlled Eddy Correlation Flux Measurements

Eddy correlation flux (ECOR) measurement system stations are used by the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility to provide surface turbulence flux measurements. In recent years, ARM has significantly enhanced its ECOR systems and made them available at all its primary research observatories and mobile facilities. However, the original ECOR data were not corrected through common eddy correlation corrections and still contain suspicious data due to instrument and measurement uncertainties. Such uncertainties in the ECOR surface turbulence fluxes hampered their uses by the user community. To improve the ECOR data, we develop a value-added product (VAP) —the Quality-Controlled Eddy Correlation Flux (QCECOR) — by applying the following necessary corrections and quality control (QC) procedures: Eddy correlation corrections. Determination of the quality-controlled energy fluxes from the corrected ECOR fluxes. Stringent QC checks. Flagging possible incorrect fluxes due to hydrometeor impacts using the collocated surface energy balance system (SEBS) wetness measurements. The QCECOR VAP currently contains two variables: surface latent heat flux (LH) and sensible heat flux (SH), together with their QC flags. When SEBS are collocated with ECOR, the wetness measurements from SEBS are used to flag the LH that may be incorrect due to hydrometeors such as precipitation, dew, or frost. An indeterminate flag is given to those that fail the wetness test. The QCECOR data are currently available at the Southern Great Plains (SGP) atmospheric observatory for the ARM extended facilities of E1, E3, E5, E6, E10, E14, E16, E21, E24, E31, E33, E37, E38, E39, and E41 updated to 2018. The data are also available at the following AMF sites: PYE (Point Reyes, 2005), NIM (Niamey, Niger, 2006), FKB (Black Forest, Germany, 2007), HFE (Shouxian, China, 2008), GRW (Azores, 2009 to 2010), and MAO (Manacapuru, Brazil, 2014-2015). The algorithm is now in the process of moving to production mode. After that, QCECOR will run automatically for all available ARM sites.

47 OTHER INSTRUMENTATION↗

Surface Cleaning Techniques: Ultra-Trace ICP-MS Sample Preparation and Assay of HDPE

The world’s most sensitive radiation detection and assay systems depend upon ultra-low background (ULB) materials to reduce unwanted radiological backgrounds. Herein, we evaluate methods to clean HDPE, a material of interest to ULB systems and the means to provide rapid assay of surface and bulk contamination. ULB level material and ultra-trace level detection of actinide elements is difficult to attain, due to the introduction of contamination from sample preparation equipment such as pipette tips, sample vials, forceps, etc. and airborne particulate. To date, literature available on the cleaning of such polymeric materials and equipment for ULB applications and ultra-trace analyses is limited. For these reasons, a study has been performed to identify an effective way to remove surface contamination from polymers in an effort to provide improved instrumental detection limits. Inductively Coupled Plasma Mass Spectroscopy (ICP-MS) was utilized to assess the effectiveness of a variety of leachate solutions for removal of inorganic uranium and thorium surface contamination from polymers, specifically high density polyethylene (HDPE). HDPE leaching procedures were tested to optimize contaminant removal of thorium and uranium. Calibration curves for thorium and uranium ranged from 15 ppq (fg/mL) to 1 ppt (pg/mL). Detection limits were calculated at 6 ppq for uranium and 7 ppq for thorium. Results showed the most effective leaching reagent to be clean 6 M nitric acid for 72 hour exposures. Contamination levels for uranium and thorium found in the leachate solutions were significant for ultralow level radiation detection applications.

HDPE, Leaching, Ultra-trace, ICP-MS, Uranium, Thor↗

Phase contrast portal imaging using synchrotron radiation

Microbeam radiation therapy is an experimental form of radiation treatment with great potential to improve the treatment of many types of cancer. We applied a synchrotron radiation phase contrast technique to portal imaging to improve targeting accuracy for microbeam radiation therapy in experiments using small animals. An X-ray imaging detector was installed 6.0 m downstream from an object to produce a high-contrast edge enhancement effect in propagation-based phase contrast imaging. Images of a mouse head sample were obtained using therapeutic white synchrotron radiation with a mean beam energy of 130 keV. Compared to conventional portal images, remarkably clear images of bones surrounding the cerebrum were acquired in an air environment for positioning brain lesions with respect to the skull structure without confusion with overlapping surface structures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Concepts for Improving Dynamic Range in (M)PDV Systems

Presentation provides overview of new concepts for improving dynamic range in (M)PDV systems by modulating launch power and dynamically refocusing probe optics, which could improve collection over a wider range of probe-surface distances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Maintenance of contamination sensitive surfaces on board long-term space vehicles

In the current age, highly sensitive instruments are being flown on spacecraft, and questions of contamination have become important. The present investigation is concerned with the available approaches which can provide long-term protection for contamination sensitive surfaces. Aspects and sources of spacecraft contamination are examined, taking into account materials outgassing, particulates, propulsion system interaction, overboard venting, man-made and cosmic debris, and atomic oxygen/ambient atmosphere interaction. Suitable protection approaches provided by current technology are discussed, giving attention to aperture covers, a possibility for a retractable cover design, gaseous purges, options for prolonging the lifetime of the thermal control system, and plume shields. Some new possibilities considered are related to an early warning system for excessive amounts of contamination, a molecular/wake shield, and the use of atomic oxygen.

Phillips, A.↗

Status and Operations at the Granite Island, Michigan (GIM) BSRN Station

In June 2018, a new surface radiation site was established on Granite Island, Michigan (GIM), located in Lake Superior. GIM is a 0.1 square km (2.5 acre) rock island. GIM moved from candidate to active and became a fully-fledged member of the Baseline Surface Radiation Network (BSRN) in July 2020 (BSRN Label: GIM). The installation is solar powered, and autonomous instrument functions are accessed remotely from Hampton, Virginia, USA. The original motivation to establishing surface radiation measurements at GIM was to combine high quality downwelling shortwave and longwave measurements with existing evaporation measurements that could lead to improved understanding of the Earth’s energy budget. Other scientific benefits are the addition of a new "water" site to the BSRN network (Water sites are rare in the BSRN network) and a surface validation site for satellite measurements such as the Clouds and the Earth’s Radiant Energy System (CERES). In this poster, we present the status of GIM. GIM is equipped with standard downwelling flux at visible and infrared wavelengths as required by the BSRN network. Basic meteorological parameters are being monitored, as well as other data collections for aerosol and total column water vapor, PAR, and lake skin temperature. Lastly, the capabilities to clean shortwave optics remotely will be discussed and a current list of instruments and pictures will be displayed.

Bryan Fabbri↗

Infrared Thermometer (IRT) Instrument Handbook

The Infrared Thermometer (IRT) is a ground-based radiation pyrometer that provides measurements of the equivalent blackbody brightness temperature of the scene in its field of view. The downwelling version has a narrow field of view for measuring sky temperature and for detecting clouds. The upwelling version has a wide field of view for measuring the narrowband radiating temperature of the ground surface.

47 OTHER INSTRUMENTATION↗

ChemCam investigation of the John Klein and Cumberland drill holes and tailings, Gale crater, Mars

The ChemCam instrument on the Mars Science Laboratory rover analyzed the rock surface, drill hole walls, tailings, and unprocessed and sieved dump piles to investigate chemical variations with depth in the first two martian drill holes and possible fractionation or segregation effects of the drilling and sample processing. Furthermore, the drill sites are both in Sheepbed Mudstone, the lowest exposed member of the Yellowknife Bay formation. Yellowknife Bay is composed of detrital basaltic materials in addition to clay minerals and an amorphous component. The drill tailings are a mixture of basaltic sediments and diagenetic material like calcium sulfate veins, while the shots on the drill site surface and walls of the drill holes are closer to those pure end members. The sediment dumped from the sample acquisition, processing, and handling subsystem is of similar composition to the tailings; however, due to the specifics of the drilling process the tailings and dump piles come from different depths within the hole. This then allows the ChemCam instrument to analyze samples representing the bulk composition from different depths. On the pre-drill surfaces, the Cumberland site has a greater amount of CaO and evidence for calcium sulfate veins, than the John Klein site. But, John Klein has a greater amount of calcium sulfate veins below the surface, as seen in mapping, drill hole wall analysis, and observations in the drill tailings and dump pile. In addition, the Cumberland site does not have any evidence of variations in bulk composition with depth down the drill hole, while the John Klein site has evidence for a greater amount of CaO (calcium sulfates) in the top portion of the hole compared to the middle section of the hole, where the drill sample was collected.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of electron microscopes with binary pseudo-random multilayer test samples

Verification of the reliability of metrology data from high quality x-ray optics requires that adequate methods for test and calibration of the instruments be developed. For such verification for optical surface profilometers in the spatial frequency domain, a modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays has been suggested [Proc. SPIE 7077-7 (2007), Opt. Eng. 47(7), 073602-1-5 (2008)} and proven to be an effective calibration method for a number of interferometric microscopes, a phase shifting Fizeau interferometer, and a scatterometer [Nucl. Instr. and Meth. A 616, 172-82 (2010)]. Here we describe the details of development of binary pseudo-random multilayer (BPRML) test samples suitable for characterization of scanning (SEM) and transmission (TEM) electron microscopes. We discuss the results of TEM measurements with the BPRML test samples fabricated from a WiSi2/Si multilayer coating with pseudo randomly distributed layers. In particular, we demonstrate that significant information about the metrological reliability of the TEM measurements can be extracted even when the fundamental frequency of the BPRML sample is smaller than the Nyquist frequency of the measurements. The measurements demonstrate a number of problems related to the interpretation of the SEM and TEM data. Note that similar BPRML test samples can be used to characterize x-ray microscopes. Corresponding work with x-ray microscopes is in progress.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration, modeling, parameterization, and verification of the instrument transfer function of an interferometric microscope

Interferometric microscopes are used to measure surface roughness, from which the computed power spectral density function can be used to extract bandwidth-limited values of the various surface properties, such as root-mean-square (rms) height and slope errors. Measurements with a microscope equipped with different objectives that have an overlapping spatial frequency range usually give different rms results over the common frequency bandwidth. This is a result of different instrument transfer functions (ITFs) that attenuate spatial frequencies by different amounts over the overlapping range. We report on the use of binary pseudo-random array (BPRA) standards to characterize the ITF of an interferometric microscope with the various objectives. We use a simple model of a 1D binary Results show that the spectrum for an undersampled array is a cosine function, rather than a straight line, constant white noise spectrum. We have an analytical model of the ITF that includes the effects of an obscured aperture and defocus, in addition to the usual parameters of numerical aperture, wavelength, and sampling period. In addition, the model includes the effect of aliasing of spatial frequency components beyond the Nyquist back into the sub-Nyquist region. We compare the model PSD predictions to the measurements performed with different objectives. Departures of the measured PSDs from the model predictions indicate that there are higher-order ITF corrections yet to be identified and included in the model.

Takacs, PZ↗

Analysis of the light scattering interferometry for spheres larger than the light wavelength

A theoretical model, based on the geometrical optics approach, has been developed to simulate various aspects of the phase Doppler particle analyzer (PDPA). The model has taken into consideration the non-uniform (Gaussian) illumination of the particles as they pass through the probe volume. Instrument response curves have been generated for various scattering angles by performing spatial and temporal integration of the scattered intensity distribution over the receiver surface. Experimental and theoretical investigations have established the applicability of this instrument to both forward and backscatter angles.

Bachalo, W. D.↗

Response characteristics of the phase Doppler particle analyzer for sizing spherical particles larger than the light wavelength

A theoretical model, based on the geometrical optics approach, has been developed to simulate various aspects of the phase Doppler particle analyzer (PDPA). The model has taken into consideration the nonuniform (Gaussian) illumination of the particles as they pass through the measurement probe volume. Instrument response curves have been generated for various scattering angles by performing spatial and temporal integration of the scattered intensity distribution over the receiver surface. Experimental and theoretical investigations have established the applicability of this instrument to both forward scattered and backscattered angles.

Sankar, Subramanian V.↗

Experience With Bayesian Image Based Surface Modeling

Bayesian surface modeling from images requires modeling both the surface and the image generation process, in order to optimize the models by comparing actual and generated images. Thus it differs greatly, both conceptually and in computational difficulty, from conventional stereo surface recovery techniques. But it offers the possibility of using any number of images, taken under quite different conditions, and by different instruments that provide independent and often complementary information, to generate a single surface model that fuses all available information. I describe an implemented system, with a brief introduction to the underlying mathematical models and the compromises made for computational efficiency. I describe successes and failures achieved on actual imagery, where we went wrong and what we did right, and how our approach could be improved. Lastly I discuss how the same approach can be extended to distinct types of instruments, to achieve true sensor fusion.

Stutz, John C.↗

Ground Reflectance Measurements from Thematic Mapper Data

Satellite radiance data are measures of solar radiation that has been reflected by the Earth's surface and scattered and absorbed by atmospheric gases and aerosols. Of concern to geologists are the surface reflectance and the degrading effects on surface resolution and albedo contrast introduced by atmospheric phenomena. The objects of this research have been to: (1) provide an empirical relationship between scanner radiance and ground reflectance allowing interpretation of the satellite data in terms of the surface parameter, and (2) assess the precision with which surface spectral reflectance may be recovered from LANDSAT-4 TM data in the presence of perturbing atmospheric and instrumental factors. The approach is field-oriented, and utilizes ground observations of surface spectral reflectance with portable spectrometers and radiometers to develop the required empirical relationships.

Conel, J. E.↗

Thin film deployable reflector model for ET gamma ray imaging telescope system (ET-GRITS)

The Marshall Space Flight Center is developing a thin film reflector for a Gamma Ray Imaging Telescope System (GRITS) using the Shuttle External Tank (ET). The concept is to install an inflatable reflector in the ET that could be transferred from the orbiter in orbit. This is a study of a scale model reflector for the ET GRITS application. The approach is to form 1/2 mil film into a spherical mirror mounted on a seven-foot diameter metal ring. The ring mount is sealed and slightly evacuated to pressurize the film into shape. Several different fabrication techniques were investigated using seamed gore designs to form the reflector. Also studied was casting a film into a seamless circular sheet. The goal for this model was to achieve a one milliradian (rms) surface curvature error over 90 percent of the reflector area. This curvature was measured by a laser scanning instrument. The results show how different reflector designs and fabrication techniques contribute to surface curvature and focusing errors.

Huegele, Vinson B.↗