Search NASA⌕ Search

SEARCH · Search NASA

Results for “system value”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

High-Efficiency Modular SiC-based Power-Converter for Flexible-CHP Systems with Stability-Enhanced Grid-Support Functions

This project seeks to develop a modular, scalable MV power converter featuring stability-enhanced grid-support functions for future grid-interface applications in flexible combined heat and power (F-CHP) cogeneration plants, being fully compliant with the IEEE Standard 1547, category B—for operation in local areas with high aggregated distributed energy resource (DER) penetration, and also with the IEEE standard for the specification of microgrid controllers, namely IEEE Std 2030.7, with the goal to enable F-CHP systems for both microgrid and standalone applications. Further, the proposed converter will use a modular circuit topology, the MMC, which is scalable both in voltage and current by interconnecting power-cell building blocks, thus flexibly suiting the needs of F-CHP systems in the 1–20 MWe range. Furthermore, the use of 10 kV SiC MOSFET devices will minimize the number of power-cells needed to operate in 2–13.8 kV MV distribution systems, but more importantly, they will render feasible a power conversion efficiency > 98 %, and a power density > 10 kW/l. This is highly relevant given that these are two key performance metrics that will further increase the value of F-CHP systems by shortening the time required to recover their investment costs.

14 SOLAR ENERGY↗

Final Seismic Shake Table Test Plan

The Spent Fuel Waste Disposition (SFWD) program is planning to conduct a full-scale seismic shake table test on the dry storage systems of spent nuclear fuel (SNF) to close the gap related to seismic loads on fuel assemblies in dry storage systems. This test will allow for quantifying the strains and accelerations on surrogate fuel assembly hardware and cladding during earthquakes of different magnitudes and frequency content. Full-scale testing is needed because a dry storage system is a complex and highly nonlinear system making it hard to predict (model) the responses to seismic excitations. The non-linearity arises from the multiple spatial gaps in the system – between fuel rods and the basket, between the basket and dry storage canister, between the dry storage canister and the storage cask (overpack), and ventilation gaps. The non-linearities pose significant limitations on the value of tests with scaled systems.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Coordinated Optimization of Multiservice Dispatch for Energy Storage Systems with Degradation Model for Utility Applications

The rapid development of energy storage technologies is motivating researchers to understand the possible value of energy storage. This paper evaluates the multiservice dispatch of distribution-sited energy storage systems with realistic degradation models by integrating a multiservice optimization model with a distribution system simulator. This work attempts to define the theoretical value energy storage can bring when multiple value streams are considered in the modeling environment. Use cases presented in this paper deliver multiple services to both distribution and transmission stakeholders that can provide positive net value to the electricity system under prevailing energy storage cost structures. Furthermore, this work was performed in collaboration with a distribution utility to help utility personnel understand the value distributed energy storage can provide by examining different utility use cases without considering implementation costs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analysis of the Value Proposition of High-Efficiency, Multijunction Solar Modules for Residential Rooftop Installations

Utilizing detailed bottom-up models, we analyze the potential markets for high-efficiency photovoltaic modules in the United States. We first estimate the fraction of area-constrained residential rooftops that could benefit from increasing the availability of high-efficiency systems. We then model the impact of efficiency on installed system costs in these area-constrained scenarios. Finally, we explore the value proposition of high-efficiency, fixed-tilt micro-concentrator photovoltaic modules in a series of case studies of residential customers, modeling the levelized cost of energy, payback period, and annual bill savings. We find that efficiency can provide significant savings in installed system cost and improve value to the solar system owner. The improvement in value depends on location and the size of the rooftop, as well as the ability of a given technology to collect diffuse light and achieve low module costs.

14 SOLAR ENERGY↗

Zero-valent iron (ZVI) Activation of Persulfate (PS) for Degradation of Para-Chloronitrobenzene in Soil

Para-chloronitrobenzene (p-CNB) in soil has posed significant health risks because of its persistence and high toxicity. The efficacy of catalyzed Zero-Valent Iron (ZVI), activated persulfate, and ZVI-persulfate processes for the degradation of p-CNB in soil was investigated. The p-CNB removal rate significantly increased from 10.8 to 90.1% with increased ZVI dosage from 0.1 mmol g{sup −1} to 1.0 mmol g{sup −1}. The p-CNB removal increased with the decrease of initial pH and a removal efficiency of 85.3% was obtained at an initial pH value of 6.8 in combined system. The p-CNB removal rate in the single persulfate system and ZVI system was 36.5% and 60.2%, while the ZVI-persulfate system showed more sufficient p-CNB removal capacity and the removal rate of p-CNB was 88.7%. Scanning electron microscopy (SEM) and Electron paramagnetic resonance (EPR) was adopted in order to explore the degradation mechanism by ZVI-Persulfate system in soil.

54 ENVIRONMENTAL SCIENCES↗

Finite-size effects in the dynamic conductivity and Faraday effect of quantum anomalous Hall insulators

Here, we theoretically study the finite-size effects in the dynamical response of a quantum anomalous Hall insulator in the disk geometry. Semianalytic and numerical results are obtained for the wave functions and energies of the disk within a continuum Dirac Hamiltonian description subject to a topological infinite mass boundary condition. Using the Kubo formula, we obtain the frequency-dependent longitudinal and Hall conductivities and find that optical transitions between edge states contribute dominantly to the real part of the dynamic Hall conductivity for frequency values both within and beyond the bulk band gap. We also find that the topological infinite mass boundary condition changes the low-frequency Hall conductivity to e 2 / h in a finite-size system from the well-known value e 2 / 2 h in an extended system. The magneto-optical Faraday rotation is then studied as a function of frequency for the setup of a quantum anomalous Hall insulator mounted on a dielectric substrate, showing both finite-size effects of the disk and Fabry-Pérot resonances due to the substrate. Our work shows the vital role played by the boundary condition in the topological properties of finite-size systems through its effects on the electronic wave functions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

FY23 Progress Report on Viscosity and Thermal Conductivity Measurements of Molten Salts

As presented in this report, thermal conductivity and viscosity measurements were performed on key chloride pseudo-binary molten salt systems of relevance to molten salt reactor developers. Thermal conductivity measurements were conducted with a variable gap technique, in which a known heat flux is driven across a molten salt specimen and the temperature difference is measured, allowing calculation of the thermal conductivity. This is achieved by establishing a small gap between the bottom of a cylindrical inner containment, which houses electrical heating elements, and an outer containment, which houses cooling channels; the gap size can be varied by compression of a formed bellows. A new calibration scheme was developed herein, involving a correction factor to the heat flux based on He measurements at various temperatures. Furthermore, the data processing methodology was improved to minimize the impact of radiative heat transfer in the calculation of salt specimen thermal conductivity from the temperature difference measurements. Viscosity measurements were conducted with a rolling ball viscometer, in which a ball rolls some known distance in an angled tubular crucible, and the terminal velocity can be used to calculate the viscosity of the salt. The measurement can be performed in a quartz crucible, with which a standard camera can be used to track the ball, or in a metal crucible, with which x-ray radiography is required to track the ball. A new custom x-ray system was made and dedicated to the rolling ball viscometer to enable high throughput automated measurements with salts which require containment with metal. Both systems have been integrated with a ventilation stack which allows for off-gassing of radioactive material, enabling future measurements with U-bearing salts. The thermal conductivity measurements performed herein were with NaCl-KCl (44 mol% NaCl). This salt system was measured in the previous fiscal year, however the thermal conductivity values obtained were comparatively low, and so the system was remeasured with the aforementioned calibration scheme and improved post-processing techniques. The newly obtained thermal conductivity values for NaCl-KCl (44 mol% NaCl) indicate good agreement with kinetic theory and ab-initio models (within 5–10 %). The viscosity measurements performed herein were with three different compositions of NaCl-KCl: 75, 50, and 25 mol% NaCl; a new calibration scheme was applied to account for variable flow effects in the laminar regime. The results show reasonable agreement with literature (5–20 %, depending on the temperature, composition, and study); however, literature values are likely higher than true values based on pure end-member measurements performed in the comparative studies. The measurements conducted herein do show a trend such that viscosity increases with increasing NaCl concentration, which agrees well with one of two comparative studies. In general, the measurements conducted herein gives confidence in the capability to use these systems to accurately measure thermal conductivity and viscosity of actinide-bearing salts within the next fiscal year.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Employing static excitation control and tie line reactance to stabilize wind turbine generators

An analytical representation of a wind turbine generator is presented which employs blade pitch angle feedback control. A mathematical model was formulated. With the functioning MOD-0 wind turbine serving as a practical case study, results of computer simulations of the model as applied to the problem of dynamic stability at rated load are also presented. The effect of the tower shadow was included in the input to the system. Different configurations of the drive train, and optimal values of the tie line reactance were used in the simulations. Computer results revealed that a static excitation control system coupled with optimal values of the tie line reactance would effectively reduce oscillations of the power output, without the use of a slip clutch.

Hwang, H. H.↗

Cost performance satellite design using queueing theory

A modified Poisson arrival, infinite server queuing model is used to determine the effects of limiting the number of broadcast channels (C) of a direct broadcast satellite used for public service purposes (remote health care, education, etc.). The model is based on the reproductive property of the Poisson distribution. A difference equation has been developed to describe the change in the Poisson parameter. When all initially delayed arrivals reenter the system a (C plus 1) order polynomial must be solved to determine the effective value of the Poisson parameter. When less than 100% of the arrivals reenter the system the effective value must be determined by solving a transcendental equation. The model was used to determine the minimum number of channels required for a disaster warning satellite without degradation in performance. Results predicted by the queuing model were compared with the results of digital simulation.

Hein, G. F.↗

Deuterium enrichment in the primitive ices of the protosolar nebula

On the basis of CH3D/CH4-ratio observations in the outer planets, the present effort to estimate the D/H ratio of the protosolar nebula's primitive ices arrives at two simple, yet effectively limiting models which constrain the degree of dilution undergone by deuterated volatiles through mixing with the initial hydrogen envelopes. These volatiles would have been contributed to planetary atmospheres by evaporated primordial ices. Ice D/H ratio model results of 0.0001 to 0.001 are compared with values for other potentially primitive material-containing bodies in the solar system, as well as with D/H ratio values from interstellar polyatomic molecules.

Lutz, Barry L.↗

Contrasting effects of bioenergy crops on biodiversity

Agriculture is driving biodiversity loss, and future bioenergy cropping systems have the potential to ameliorate or exacerbate these effects. Using a long-term experimental array of 10 bioenergy cropping systems, we quantified diversity of plants, invertebrates, vertebrates, and microbes in each crop. For many taxonomic groups, alternative annual cropping systems provided no biodiversity benefits when compared to corn (the business-as-usual bioenergy crop in the United States), and simple perennial grass–based systems provided only modest gains. In contrast, for most animal groups, richness in plant-diverse perennial systems was much higher than in annual crops or simple perennial systems. Microbial richness patterns were more eclectic, although some groups responded positively to plant diversity. Future agricultural landscapes incorporating plant-diverse perennial bioenergy cropping systems could be of high conservation value. However, increased use of annual crops will continue to have negative effects, and simple perennial grass systems may provide little improvement over annual crops.

09 BIOMASS FUELS↗

Computer-aided communication satellite system analysis and optimization

The capabilities and limitations of the various published computer programs for fixed/broadcast communication satellite system synthesis and optimization are discussed. A satellite Telecommunication analysis and Modeling Program (STAMP) for costing and sensitivity analysis work in application of communication satellites to educational development is given. The modifications made to STAMP include: extension of the six beam capability to eight; addition of generation of multiple beams from a single reflector system with an array of feeds; an improved system costing to reflect the time value of money, growth in earth terminal population with time, and to account for various measures of system reliability; inclusion of a model for scintillation at microwave frequencies in the communication link loss model; and, an updated technological environment.

Stagl, T. W.↗

In Situ UV–vis Quantification of Chlorobasicity in Binary Molten Chlorides

Optical basicity measurements provide a basis for determining the relative chlorobasicity of a given molten salt composition. This study uses Bi3+ as a spectroscopic probe to investigate optical basicity across three binary molten chloride systems (LiCl-KCl, MgCl2–KCl, and ZnCl2–KCl) through in situ UV–vis spectroscopy measurements of the 1S0→3P1 transition. LiCl-KCl systems exhibit the highest optical basicity with minimal compositional dependence, while both divalent systems show stronger, yet nonlinear, dependence that is reminiscent of acid–base titration curves. The influence of cation electronegativity and polarizing power (Li+ < Mg2+ < Zn2+) directly reflects the basicity curves, with ZnCl2–KCl displaying the steepest gradients and lowest basicity values. Nonlinear dependencies in divalent systems indicate formation of chloride-bridged network structures with coordination states dictated by the amount of KCl in a salt composition, which was further investigated and validated by molecular dynamics simulations of polymeric structures formed in ZnCl2 and MgCl2-based salts using machine learning force fields. The temperature dependence of chlorobasicity in terms of optical basicity was investigated, and a loose, positive correlation between the two was revealed. These findings establish Bi3+ as a sensitive probe for understanding electronic environments in molten chloride systems and provide insights for predicting the chemical behavior of molten salts for use in high-temperature environments.

Buttice, Kailee [Department of Nuclear Engineering↗

ON THE INJECTION OF SHORT-LIVED RADIONUCLIDES FROM A SUPERNOVA INTO THE SOLAR NEBULA: CONSTRAINTS FROM THE OXYGEN ISOTOPES

Injection of short-lived radionuclides from a nearby core-collapse Type II supernova into the already-formed solar protoplanetary disk was proposed to account for the former presence of {sup 26}Al, {sup 41}Ca, and {sup 60}Fe in the early solar system inferred from isotopic analysis of meteoritic samples. One potential corollary of this ''late-injection'' scenario is that the disk's initial (pre-injection) oxygen isotopic composition could be significantly altered, as supernova material that carried the short-lived radionuclides would also deliver oxygen components synthesized in that given star. Therefore, the change in the oxygen isotopic composition of the disk caused by injection could in principle be used to constrain the supernova injection models. Previous studies showed that although supernova oxygen could result in a wide range of shifts in {sup 17}O/{sup 16}O and {sup 18}O/{sup 16}O of the disk, a couple of cases existed where the calculated oxygen changes in the disk would be compatible with the meteoritic and solar wind data. Recently, the initial abundances of {sup 41}Ca and {sup 60}Fe in the solar system were revised to lower values, and the feasibility of supernova injection as a source for the three radionuclides was called into question. In this study, supernova parameters needed for matching {sup 26}Al, {sup 41}Ca, and {sup 60}Fe to their early solar system abundances were reinvestigated and then were used to infer the pre-injection O-isotope composition of the disk. The result suggested that a supernova undergoing mixing fallback might be a viable source for the three radionuclides.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance analysis of digital FM demodulators for fading channels in the threshold region

The quasi-optimum digital FM demodulators for fading channels reported earlier (1975) reflected the system performance accurately under high signal to noise ratio conditions. In this paper, the prediction of the system performance for low SNR values is considered. A new set of error variance algorithms is developed from the filter algorithm assuming a Gaussian distribution for the state estimation errors and taking the effect of high frequency terms into consideration. Simulation analysis for an FM system with Rician fading channel shows that these algorithms predict the system performance accurately in the threshold region.

Dharamsi, M. T.↗

Heat Exchanger Performance Impacts on Optimum Cost Conditions in Thermoelectric Energy Recovery Designs

Cost is just as important as power density or efficiency for the adoption of waste heat recovery thermoelectric generators (TEG). Prior work [1] has shown that the system design that minimizes cost (e.g., the $/W value) can be close to the designs that maximize the system’s efficiency or power density, however, it is important to understand the relationship between those designs to optimize TEG performance-cost compromises. Expanding on recent work [1, 2, 3] the impact of heat exchanger conditions on the optimum TEG fill factors and cost scaling of a waste heat recovery thermoelectric generator with a detailed treatment of the hot side exhaust heat exchanger has been investigated further. The effect of the heat lost to the environment and updated relationships between the hot-side and cold-side conductances [4] that maximize power output are considered. The optimum fill factor to minimize TEG energy recovery system costs is strongly dependent on the heat leakage fraction, σ, the mass flow rate of the exhaust, the hot-side heat exchanger effectiveness, heat exchanger UAh, and heat flux. These relationships are explored and characterized for typical exhaust gas-flow conditions to show the inherent design complexities. The heat exchanger costs often dominate the TEG cost equation and it is critical to fully understand the tradeoff between heat exchanger performance, optimum TEG fill factors, and cost to establish potentially optimum design points within the cost-performance design space. This work will explore the design tradeoffs and relationships within the cost-efficiency-power density design space for a typical thermoelectric energy recovery system application. The interplay between optimum TEG fill factors and heat exchanger design can impact system footprint, volume, and mass in weight-sensitive applications. Less-effective, low-cost heat exchangers may outperform higher cost alternatives from a market adoption perspective. This shift of emphasis acknowledging the interdependence of optimum TEG fill factors and heat exchanger performance has significant implications on thermoelectric waste heat recovery systems designs and their operation. In addition, preferred TEG design regimes exist that accommodate reasonable compromises in TE performance and cost. This effort highlights how the optimum fill factor–heat exchanger performance relations couple to these optimum TEG performance-cost domains based on TEG-system-level analyses and provides a focus for future system research and development efforts.

Energy recovery↗

Techno-economic analysis of renewable energy source options for a district heating project

With the increased interest in exploiting renewable energy sources for district heating applications, the economic comparison of viable options has been considered as an important step in making a sound decision. In this paper, the economic performance of several energy options for a district heating system in Vancouver, British Columbia, is studied. The considered district heating system includes a 10 MW peaking/ backup natural gas boiler to provide about 40% of the annual energy requirement and a 2.5 MW base-load system. The energy options for the base-load system include: wood pellet, sewer heat, and geothermal heat. Present values of initial and operating costs of each system were calculated over 25-year service life of the systems, considering depreciation and salvage as a negative cost item. It was shown that the wood pellet heat producing technologies provided less expensive energy followed by the sewer heat recovery, geothermal and natural gas systems. Among wood pellet technologies, the grate burner was a less expensive option than powder and gasifier technologies. It was found that using natural gas as a fuel source for the peaking/backup system accounted for more than 40% of the heat production cost for the considered district heating center. This is mainly due to the high natural gas prices which cause high operating costs over the service life of the district heating system. Variations in several economic inputs did not change the ranking of the technology options in the sensitivity analysis. However, it was found that the results were more sensitive to changes in operating costs of the system than changes in initial investment. It is economical to utilize wood pellet boilers to provide the base-load energy requirement of district heating systems Moreover, the current business approach to use natural gas systems for peaking and backup in district heating systems could increase the cost of heat production significantly.

03 NATURAL GAS↗