Search NASA⌕ Search

SEARCH · Search NASA

Results for “variational optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Identification of host response signatures of infection.

Biological weapons of mass destruction and emerging infectious diseases represent a serious and growing threat to our national security. Effective response to a bioattack or disease outbreak critically depends upon efficient and reliable distinguishing between infected vs healthy individuals, to enable rational use of scarce, invasive, and/or costly countermeasures (diagnostics, therapies, quarantine). Screening based on direct detection of the causative pathogen can be problematic, because culture- and probe-based assays are confounded by unanticipated pathogens (e.g., deeply diverged, engineered), and readily-accessible specimens (e.g., blood) often contain little or no pathogen, particularly at pre-symptomatic stages of disease. Thus, in addition to the pathogen itself, one would like to detect infection-specific host response signatures in the specimen, preferably ones comprised of nucleic acids (NA), which can be recovered and amplified from tiny specimens (e.g., fingerstick draws). Proof-of-concept studies have not been definitive, however, largely due to use of sub-optimal sample preparation and detection technologies. For purposes of pathogen detection, Sandia has developed novel molecular biology methods that enable selective isolation of NA unique to, or shared between, complex samples, followed by identification and quantitation via Second Generation Sequencing (SGS). The central hypothesis of the current study is that variations on this approach will support efficient identification and verification of NA-based host response signatures of infectious disease. To test this hypothesis, we re-engineered Sandia's sophisticated sample preparation pipelines, and developed new SGS data analysis tools and strategies, in order to pioneer use of SGS for identification of host NA correlating with infection. Proof-of-concept studies were carried out using specimens drawn from pathogen-infected non-human primates (NHP). This work provides a strong foundation for large-scale, highly-efficient efforts to identify and verify infection-specific host NA signatures in human populations.

Branda, Steven S.↗

Implementation of test for quality assurance in nuclear medicine gamma camera

In nuclear medicine (NM) over 90% of procedures are performed for diagnostic purposes. To ensure adequate diagnostic quality of images and the optimization of the doses received by patients originated from the radioactive material is essential for regular monitoring and equipment performance through a quality assurance program (QAP). The QAP consists of 15 proposed performance tomographic and not tomographic gamma camera (GC) tests, and is based on recommendations of international organizations. We describe some results of the performance parameters of QAP applied to a GC model e.cam Siemens, of the Department of NM of the National Cancer Institute of Mexico (INCan). The results were: (1) The average intrinsic spatial resolution (R{sub in}) was 4.67 {+-} 0.25 mm at the limit of acceptance criterion of 4.4 mm. (2) The sensitivity extrinsic (S{sub ext}), with maximum variations of 1.8% (less than 2% which is the criterion of acceptance). (3) Rotational Uniformity (U{sub rot}), with values of integral uniformity (IU) in the useful field of view detector (UFOV), with maximum percentage change of 0.97% and monthly variations equal angles, ranging from 0.13 to 0.99% less than 1%. (4) The displacement of the center of rotation (DCOR), indicated a maximum deviation of 0.155 {+-} 0.039 mm less than 4.795 mm, an absolute deviation of less than 0.5 where pixel 0.085 pixel is suggested, the criteria are assigned to low-energy collimator high resolution. (5) In tomographic uniformity (U{sub tomo}), UI values (%) and percentage noise level (rms%) were 7.54 {+-} 1.53 and 4.18 {+-} 1.69 which are consistent with the limits of acceptance of 7.0-12.0% and 3.0-6.0% respectively. The smallest cold sphere has a diameter of 11.4 mm. The implementation of a QAP allows for high quality diagnostic images, optimization of the doses given to patients, a reduction of exposure to occupationally exposed workers (POE, by its Spanish acronym), and generally improves the productivity of the service. This proposal can be used to develop a similar QAP in other facilities and may serve as a precedent for the proposed regulations for quality assurance (QA) teams in MN.

61 RADIATION PROTECTION AND DOSIMETRY↗

Exploring the fusion power plant design space: comparative analysis of positive and negative triangularity tokamaks through optimization

The optimal configuration choice between positive triangularity (PT) and negative triangularity (NT) tokamaks for fusion power plants hinges on navigating different operational constraints rather than achieving specific plasma performance metrics. This study presents a systematic comparison using constrained multi-objective optimization with the integrated FUsion Synthesis Engine (FUSE) framework. Over 200 000 integrated design evaluations were performed exploring the trade-offs between capital cost minimization and operational reliability (maximizing q 95 ) while satisfying engineering constraints including 250 ± 50 MW net electric power, tritium breeding ratio > 1.1, power exhaust limits and an hour flattop time. Both configurations achieve similar cost-performance Pareto fronts through contrasting design philosophies. PT, while demonstrating resilience to pedestal degradation (compensating for up to 40% reduction), are constrained to larger machines (R 0 > 6.5 m) by the narrow operational window between L–H threshold requirements and the research-established power exhaust limit (P sol /R < 15 MW m –1 ). This forces optimization through comparatively reduced magnetic field (∼8 T). NT configurations exploit their freedom from these constraints to access compact, high-field designs (R 0 ~ 5.5 m, B 0 >12 T), creating natural synergy with advancing HTS technology. Sensitivity analyses reveal that PT’s economic viability depends critically on uncertainties in L–H threshold scaling and power handling limits. Notably, a 50% variation in either could eliminate viable designs or enable access to the compact design space. These results suggest configuration selection should be risk-informed: PT offers the lowest-cost path when operational constraints can be confidently predicted, while NT is robust to large variations in constraints and physics uncertainties.

FUSE framework↗

Bridge Testing With Ground-Based Interferometric Radar: Experimental Results

The research of innovative non-contact techniques aimed at the vibration measurement of civil engineering structures (also for damage detection and structural health monitoring) is continuously directed to the optimization of measures and methods. Ground-Based Radar Interferometry (GBRI) represents the more recent technique available for static and dynamic control of structures and ground movements.Dynamic testing of bridges and buildings in operational conditions are currently performed: (a) to assess the conformity of the structure to the project design at the end of construction; (b) to identify the modal parameters (i.e. natural frequencies, mode shapes and damping ratios) and to check the variation of any modal parameters over the years; (c) to evaluate the amplitude of the structural response to special load conditions (i.e. strong winds, earthquakes, heavy railway or roadway loads). If such tests are carried out by using a non-contact technique (like GBRI), the classical issues of contact sensors (like accelerometers) are easily overtaken.This paper presents and discusses the results of various tests carried out on full-scale bridges by using a Stepped Frequency-Continuous Wave radar system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of well design and CO 2 injection strategy for risk reduction in Class VI geological carbon sequestration wells

The safety and durability of Class VI wells are critical for geological carbon sequestration (GCS). However, current GCS operations face unique challenges: unlike traditional Class II wells, Class VI CO 2 injection wells operate at rates up to 100 times higher, dramatically increasing the risk of wellbore leakage and structural compromise due to severe temperature drops and associated mechanical stresses. Despite existing guidelines on material selection, there remains a substantial gap in understanding how rapid CO 2 injection rates, low surface temperatures, and variable reservoir conditions interact to threaten long-term well integrity. This study presents a comprehensive, original workflow integrating advanced analytical and numerical models for both well flow and well integrity analysis. By systematically simulating a wide range of field-relevant scenarios—including variations in injection rate, CO 2 temperature, and reservoir pressure—this work provides the first cross-validated assessment of cooling effects on wellbore. The results reveal that extreme temperature drops, up to 60 °C, can occur under high injection rates, particularly in depleted reservoirs, significantly increasing the risk of cement failure. Building on these insights, the study proposes innovative, practical well design and operational strategies, including ductile cement formulations, pre-stressing techniques, advanced insulation coatings, and proactive management of injection rates. The safety of Class VI well extends beyond simply using CO 2 resistant materials. Cement materials should possess optimal thermo-hydraulic-mechanical-chemical properties for effective performance. This work provides a scientific basis for optimizing Class VI well designs, with direct benefits for minimizing environmental risk, lowering operational costs, and enhancing the long-term reliability of GCS.

25 ENERGY STORAGE↗

Phase Measurements of a 140-GHz Confocal Gyro-Amplifier

The phase stability of a 140-GHz, 1-kW pulsed gyro-amplifier system and the phase dependence on the cathode voltage were experimentally measured. To optimize the measurement precision, the amplifier was operated at 47 kV and 1 A, where the output power was ~ 30 W. The phase was determined to be stable both pulse-to-pulse and during each pulse, so far as the cathode voltage and electron beam current are constant. The phase variation with voltage was measured and found to be 130 ± 30° /kV, in excellent agreement with simulations. The electron gun used in this device is non-adiabatic, resulting in a steep slope of the beam pitch factor with respect to cathode voltage. This was discovered to be the dominant factor in the phase dependence on voltage. The use of an adiabatic electron gun is predicted to yield a significantly smaller phase sensitivity to voltage, and thus a more phase-stable performance. To our knowledge, these are the first phase measurements reported for a gyro-amplifier operating at a frequency above W-band.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Efficient and Effective Personalization of PTV Margins During Radiation Therapy for Bladder Cancer

The magnitude of bladder filling variation during bladder cancer radiation therapy varies considerably between patients. Population-based approaches for planning target volume (PTV) margin calculation may be suboptimal for this disease site, and a strategy for personalizing PTV margins for each patient may be particularly beneficial. The purpose of this study was to identify the optimal number and sampling pattern of cone beam CT image data sets that are required when generating personalized PTV margins for whole bladder (WB) and partial bladder (PB) radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evolution of the mechanical properties of a cobalt-based alloy under thermal shocks

A cobalt-base alloy manufactured by hot isostatic pressing sintering (HIP) was investigated in the present work. A series of quenching thermal-shock experiments were carried out to study the effects of thermal-cycle shocks on this new cobalt-based alloy. Scanning Electron Microscope (SEM) and Energy Dispersion Spectrum (EDS) were employed to observe the evolution of microstructures under thermal-shock cycles. Results show that some floccus Co 3 W 3 C precipitated around the WC particles after several thermal-shock cycles. These precipitates and the carbide particles correspond to the locations with the high-stress concentration. The mechanical properties evolution under thermal-shock cycles was analyzed by Nanoindentation tests. The nanohardness presents no noticeable change with thermal-shock cycles. However, the reduced modulus demonstrates a decreasing trend with the thermal-shock cycles. The variation of the mechanical properties has an unestimated relationship with the residual stress and densities of dislocations caused by thermal shocks. Furthermore, the present work pointed out that the precipitates around the carbides are the places where the thermal fatigue crack initiated. How to deal with the precipitates will be the optimized way for this material.

36 MATERIALS SCIENCE↗

Effects of lithium salt concentration on graphited carbon microbead anodes in the piperidinium-based hybrid electrolytes

Graphical abstract: “Lithium aggregates” usually cause a significant decrease in Li{sup +} mobility and transfer efficiency. Therefore, as important as the problem of SEI, the content of lithium salt and the interaction between Li{sup +} and ILs’ anions should be taken into consideration in the optimization of ILs-based electrolytes for Li-ion batteries. - Highlights: • “Lithium aggregates” in piperidinium-based electrolytes are evidenced by IR and NMR. • High LiPF{sub 6} content could decrease Li{sup +} mobility due to “ionic aggregates”. • Lithium salt concentration is an important factor affecting graphite performances. - Abstract: The variations in LiPF{sub 6} concentration lead to the very different electrochemical performances of carbon microbeads anodes in the piperidinium-based hybrid electrolytes. The “two peaks” behaviors of lithium plating observed in cyclic voltammetry tests, and some detailed changes in infrared spectra and nuclear magnetic resonance indicates that the formation of “ionic aggregates” related to lithium ions”. Therefore, the excessive lithium salts in the piperidinium-based hybrid electrolytes, usually cause a significant decrease in Li{sup +} mobility and transfer efficiency. The main behaviors are that, when LiPF{sub 6} concentrations increased from 0.2 to 1.2 mol kg{sup −1}, the apparent migration energies (E{sub a}) increase largely from 8.83 to 21.16 kJ mol{sup −1}, while the lithium transference numbers (t{sub Li{sup +}}) drop markedly from 0.538 to 0.292.

36 MATERIALS SCIENCE↗

Effects of Packaging SrI2(Eu) Scintillator Crystals

Recent renewed emphasis placed on gamma-ray detectors for national security purposes has motivated 13 researchers to identify and develop new scintillator materials capable of high energy resolution and 14 growable to large sizes. We have discovered that SrI2(Eu) has many desirable properties for gamma-ray 15 detection and spectroscopy, including high light yield of ~90,000 photons/MeV and excellent light yield 16 proportionality. Furthermore, we have demonstrated growth of crack-free 2 diameter boules. We 17 have measured <2.7% FWHM at 662 keV with small detectors (<1 cm3) in direct contact with a 18 photomultiplier tube, and ~3% resolution at 662 keV is obtained for 1 in3 crystals. Due to the 19 hygroscopic nature of SrI2(Eu), proper packaging is required for field use. This work describes a 20 systematic study performed to determine the key factors in the packaging process to optimize 21 performance. These factors include proper polishing of the surface, the geometry of the crystal, 22 reflector materials and windows. A technique based on use of a collimated Cs-137 source was developed 23 to examine light collection uniformity. Employing this technique, we found that when the crystal is 24 packaged properly, the variance in the pulse height at 662 keV from events near the bottom of the 25 crystal compared to those near the top of the crystal could be reduced to <1%. This paper describes the 26 design and engineering of our detector package in order to improve energy resolution of 1 in3-scale 27 SrI2(Eu) crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiplexed Cancer Biomarker Detection Using Quartz-based Photonic Crystal Surfaces

A photonic crystal (PC) surface is demonstrated as a high-sensitivity platform for detection of a panel of 21 cancer biomarker antigens using a sandwich enzyme-linked immunosorbent assay (ELISA) microarray format. A quartz-based PC structure fabricated by nanoimprint lithography, selected for its low autofluorescence, supports two independent optical resonances that simultaneously enable enhancement of fluorescence detection of biomarkers and label-free quantification of the density of antibody capture spots. A detection instrument is demonstrated that supports fluorescence and label-free imaging modalities, with the ability to optimize the fluorescence enhancement factor on a pixel-by-pixel basis throughout the microarray using an angle-scanning approach for the excitation laser that automatically compensates for variability in surface chemistry density and capture spot density. Measurements show that the angle-scanning illumination approach reduces the coefficient of variation of replicate assays by 20–99% compared to ordinary fluorescence microscopy, thus supporting reduction in limits of detectable biomarker concentration. Using the PC resonance, biomarkers in mixed samples were detectable at the lowest concentrations tested (2.1–41 pg/mL), resulting in a three-log range of quantitative detection.

Huang, Cheng-Sheng↗

Quantifying the Value of Technology and Policy Innovation in Water Resource Portfolios

Abstract Recent water infrastructure planning models demonstrate that explicitly accounting for hydrological changes in long‐term water planning reduces costs and increases system robustness. However, current models do not consider the effects of other changes occurring in the system over long time horizons, namely technology and policy innovation. By leveraging state‐of‐the‐art dynamic control techniques, we propose a suite of tools that explicitly relate hydrologic change, technology innovation, and policy interventions to system‐level water costs. We design robust and cost‐optimal strategies for water supply expansion under hydrological variability and hundreds of plausible innovation states, for example, treatment cost and diversification improvements, deployment times, and demand reduction campaigns. Our approach circumvents the need to pre‐assign probabilities to innovation scenarios and, instead, directly calculates the effects of technology, policy, and hydrology variations on system cost and planning strategies to identify avenues of impactful innovation. These tools can support technology development hubs, urban, state, and federal water planners in anticipating cost implications of technology and policy innovation at the local level, and prioritizing high‐impact innovation goals based on quantitative targets. Results for the case study of Santa Barbara, California identify high‐value innovation attributes for the city as well as combinations of innovation attributes across technologies and policies, and quantify their potential utility cost reductions.

13 HYDRO ENERGY↗

Nanoscale mapping of heterogeneity of the polarization reversal in lead-free relaxor–ferroelectric ceramic composites

Relaxor/ferroelectric ceramic/ceramic composites have shown to be promising in generating large electromechanical strain at moderate electric fields. However, the mechanisms of polarization and strain coupling between grains of different nature in the composites remain unclear. To rationalize the coupling mechanisms we performed advanced piezoresponse force microscopy (PFM) studies of 0.92BNT-0.06BT-0.02KNN/0.93BNT-0.07BT (ergodic/non-ergodic relaxor) composites. PFM is able to distinguish grains of different phases by characteristic domain patterns. Polarization switching has been probed locally, on a sub-grain scale. k-Means clustering analysis applied to arrays of local hysteresis loops reveals variations of polarization switching characteristics between the ergodic and non-ergodic relaxor grains. Here, we report a different set of switching parameters for grains in the composites as opposed to the pure phase samples. These results confirm ceramic/ceramic composites to be a viable approach to tailor the piezoelectric properties and optimize the macroscopic electromechanical characteristics.

36 MATERIALS SCIENCE↗

Analysis of core asymmetries in inertial confinement fusion implosions using three-dimensional hot-spot reconstruction

Three-dimensional effects play a crucial role during the hot-spot formation in inertial confinement fusion (ICF) implosions. A data analysis technique for 3D hot-spot reconstruction from experimental observables has been developed to characterize the effects of low modes on 3D hot-spot formations. In nuclear measurements, the effective flow direction, governed by the maximum eigenvalue in the velocity variance of apparent ion temperatures, has been found to agree with the measured hot-spot flows for implosions dominated by mode ℓ = 1. Asymmetries in areal-density (ρR) measurements were found to be characterized by a unique cosine variation along the hot-spot flow axis. In x-ray images, a 3D hot-spot x-ray emission tomography method was developed to reconstruct the 3D hot-spot plasma emissivity using a generalized spherical-harmonic Gaussian function. The gradient-descent algorithm was used to optimize the mapping between the projections from the 3D hot-spot emission model and the measured x-ray images along multiple views. Furthermore, this work establishes a platform to analyze 3D low-mode core asymmetries in ICF.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Doping-depenent specific heat study of the superconducting gap in Ba(Fe1-xCox)2As2

We report a doping, magnetic field, and low-temperature-dependent study of the specific heat of the iron-arsenide Ba(Fe{sub 1-x}Co{sub x}){sub 2}As{sub 2} at underdoped (x=0.045), optimal-doped (x=0.08) and overdoped (x=0.103 and 0.105) regimes. By subtracting the lattice specific heat the temperature and magnetic field dependence of the electronic specific heat has been studied. The temperature and field dependencies of the superconducting part of Cp exhibit similar behavior for all doping concentrations. The temperature variation in the electronic specific heat as well as its field dependence cannot be described by a single isotropic s-wave gap, pointing to a complex gap structure in the system. The lack of doping dependence indicates that the gap structure does not change significantly as a function of doping. We also observe a significant residual linear term of unknown origin in the specific heat of Ba(Fe{sub 1-x}Co{sub x}){sub 2}As{sub 2} which suggests that inhomogeneity may be an important factor in Co-doped BaFe{sub 2}As{sub 2}.

36 MATERIALS SCIENCE↗

SU-E-I-32: Benchmarking Head CT Doses: A Pooled Vs. Protocol Specific Analysis of Radiation Doses in Adult Head CT Examinations

Purpose: The aim of this study was to collect CT dose index data from adult head exams to establish benchmarks based on either: (a) values pooled from all head exams or (b) values for specific protocols. One part of this was to investigate differences in scan frequency and CT dose index data for inpatients versus outpatients. Methods: We collected CT dose index data (CTDIvol) from adult head CT examinations performed at our medical facilities from Jan 1st to Dec 31th, 2014. Four of these scanners were used for inpatients, the other five were used for outpatients. All scanners used Tube Current Modulation. We used X-ray dose management software to mine dose index data and evaluate CTDIvol for 15807 inpatients and 4263 outpatients undergoing Routine Brain, Sinus, Facial/Mandible, Temporal Bone, CTA Brain and CTA Brain-Neck protocols, and combined across all protocols. Results: For inpatients, Routine Brain series represented 84% of total scans performed. For outpatients, Sinus scans represented the largest fraction (36%). The CTDIvol (mean ± SD) across all head protocols was 39 ± 30 mGy (min-max: 3.3–540 mGy). The CTDIvol for Routine Brain was 51 ± 6.2 mGy (min-max: 36–84 mGy). The values for Sinus were 24 ± 3.2 mGy (min-max: 13–44 mGy) and for Facial/Mandible were 22 ± 4.3 mGy (min-max: 14–46 mGy). The mean CTDIvol for inpatients and outpatients was similar across protocols with one exception (CTA Brain-Neck). Conclusion: There is substantial dose variation when results from all protocols are pooled together; this is primarily a function of the differences in technical factors of the protocols themselves. When protocols are analyzed separately, there is much less variability. While analyzing pooled data affords some utility, reviewing protocols segregated by clinical indication provides greater opportunity for optimization and establishing useful benchmarks.

60 APPLIED LIFE SCIENCES↗

Coupling of high-resolution mass spectrometer and photosynthesis system for comprehensive leaf volatile metabolite profiling

Background Leaf-level biogenic volatile organic compounds (BVOCs) emissions represent a major source of organic gases in the atmosphere, influencing both climate and air quality. These emissions are strongly driven by environmental perturbations, which affect individual plant- to ecosystem-level processes. Uncovering all the BVOCs and understanding how their emissions respond to altered environmental conditions provide critical insights into vegetation-driven changes in atmospheric chemistry. We developed a tandem instrumentation setup that integrates a proton transfer reaction time-of-flight mass spectrometer (PTR-ToF-MS) with parts-per-trillion detection limits and a photosynthetic infrared gas exchange system for the untargeted survey of all the BVOCs. This novel system enables simultaneous, real-time monitoring of BVOC emissions and photosynthetic parameters at the leaf level, offering new opportunities to disentangle the physiological and environmental drivers of VOC release. Furthermore, we established the VOC Analysis and Processing Optimization Resource (VAPOR), an open-access software tool designed for rapid data post-processing and the analysis of the variability of hundreds of BVOCs. We assessed the performance of the tandem system under varying background conditions, using standard gas mixtures and a range of environmental factors. Results Blank emissions were substantially lower for major BVOCs (e.g., isoprene) compared to those observed in plant emissions. Despite this, the observation of background-level VOCs highlights the importance of routinely acquiring and accounting for blank measurements in analyses using the coupled instrumentation. Introduction of known VOC concentrations to the system demonstrated a linear response across different compounds with varying molecular compositions, indicating minimal gas loss regardless of chemical moieties within the coupled instrumentation. We applied the optimized system to investigate the physiological mechanisms driving BVOC emissions across different genotypes of poplar and pennycress. The high mass resolution capabilities of the PTR-ToF-MS, coupled with comprehensive VAPOR-driven data analysis, enabled the identification of several important BVOCs, including methanol and methanethiol; these BVOCs displayed substantial variation across pennycress genotypes and showed concentrations ~ 100–350% higher than the blank. Moreover, isoprene emissions varied significantly among poplar genotypes grown in different potting media. Conclusions Tandem instrumentation offers a powerful tool for profiling volatile molecular markers and elucidating their genetic and environmental underpinnings. This approach enhances our ability to predict BVOC emissions in response to genotype by environmental interactions and contributes to a deeper understanding of vegetation responses to environmental changes.

Biogenic volatile organic compounds↗

Effects of chemistry and microstructure on corrosion performance of Zircaloy-2-based BWR cladding - 2016-0066

In boiling water reactors (BWRs), Zircaloy-2 is typically the material of choice for fuel cladding. With increased focus on fuel performance and reliability, consistent cladding corrosion performance under varying BWR conditions has become an acknowledged requirement for modern BWR fuel. To support optimization of corrosion performance, modifications to alloy chemistry and manufacture conditions can be made, supported by ex-reactor corrosion testing and demonstrated through in-reactor operation. In this work, the combined effects of alloy chemistry and fabrication process were investigated. The effect of alloy chemistry is often complicated by variation within a production ingot. In this work, additional measurements were intentionally taken at the tube-shell stage (before cold pilgering) so that chemistry more representative of the final cladding could be obtained and the effect of iron, nickel, and tin could be examined more closely. Although chemistry range of Zircaloy-2 was the primary focus, the effect of iron above the ASTM limit in a new alloy was also explored. Three types of cladding fabrication processes were considered. Two types included a heat treatment applied after the first cold pilgering and annealing, and the treatment was limited to the outer portion of the cladding and differed in the temperature of the heat treatment; the third type had no special heat treatments after the first cold pilgering and annealing. The weight gain of the three types of cladding with varying compositions under two corrosion test conditions (400 deg. C steam and 410/520 deg. C two-stage steam) are discussed in terms of the initial second-phase particle sizes obtained from transmission electron microscopy examinations. Based on poolside inspections and hot-cell examinations, the in-reactor corrosion performance of the two cladding types up to typical discharge exposures are discussed in the terms of corrosion margin, microstructure evolution, and correlation with ex-reactor corrosion test data. (authors)

36 MATERIALS SCIENCE↗