Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Integrated control of individual plasma scalars with simultaneous neoclassical tearing-mode suppression

A novel integrated-control architecture has been tested in nonlinear, one-dimensional simulations using the control-oriented transport simulator (COTSIM©) and in DIII-D experiments. Integrated architectures that can perform continuous-mission control while also handling off-normal events will be vital in future reactor-grade tokamaks. Continuous-mission controllers for individual magnetic and kinetic scalars (thermal stored-energy (W), volume-average toroidal rotation (Ω Φ ), and safety factor profile (q) at different spatial locations) have been integrated in this work with event-triggered neoclassical tearing-mode (NTM) suppression controllers by combining them into an architecture augmented by a supervisory and exception handling (S&EH) system and an actuator management (AM) system. Here, the AM system, which enables the integration of competing controllers, solves in real time a nonlinear optimization problem that takes into account the high-level control priorities dictated by the S&EH system. The resulting architecture offers a high level of integration and some of the functionalities that will be required to fulfill the advanced-control requirements anticipated for ITER. Initial simulations using COTSIM suggest that the plasma performance and its MHD stability may be improved under integrated feedback control. In addition, the integrated-control architecture has been implemented in the DIII-D plasma control system and tested experimentally for the first time ever in DIII-D in a high-q min scenario, which is a candidate for steady-state operation in ITER.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System

This paper develops an improved control strategy of grid-forming (GFM) inverters with fault ride-through capabilities to guarantee the stable operation of microgrids under fault conditions, especially islanded microgrids and asymmetrical faults. The proposed control strategy includes the dual control of positive-sequence and negative-sequence control as well as the adaptive virtual impedance (VI) control. Unlike existing works, the proposed strategy applies the VI control for only the d component of the positive-sequence control and leaves the q component of the positive-sequence control and the dq component of the negative-sequence control as zero, thus achieving improved stability and balanced three-phase voltages under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults, which could cause the saturation of the inner current loop and instability if the VI is not adaptive. Simulation results of various unbalanced faults with high- and low-fault impedances show that the proposed control strategy improves the stability of the GFM inverter and achieves stable and balanced output voltages in islanded microgrids. And the algorithm also improves the stability of GFM inverters under balanced faults with high- and low-fault impedances.

adaptive virtual impedance control↗

A Distributed Control Architecture for Cascaded H-Bridge Converter with Integrated Battery Energy Storage

Cascaded H-bridge topology has been used in grid-tied converters for battery energy storage system due to its modular structure. To fully utilize the converter’s modularity, this paper proposes a hierarchical distributed control architecture that consists of primary control, secondary control and battery state of charge (SOC) balancing control. Primary control ensures accurate current tracking while a distributed secondary control based on consensus algorithm is presented to regulate power sharing among modules and is proved to be stable theoretically. Here, a distributed SOC balancing control is further introduced to improve energy efficiency of battery energy storage system. Finally, the hierarchical distributed control strategy is implemented using hardware controllers and a software platform. Besides, a carrier phase shift control is also implemented to achieve multilevel output voltage and harmonic reduction. The experimental results demonstrate the performance of the proposed control scheme effectively.

25 ENERGY STORAGE↗

Control Design for a Marine Hydrokinetic Cycloturbine Vehicle

Abstract Marine Hydrokinetic (MHK) cycloturbines generate sustainable power by exploiting tidal currents. By powering the turbines and using pitching foils for control, a vehicle comprised of MHK cycloturbines also has the ability to station keep and maneuver. The vehicle consists of four counter-rotating cycloturbines, with hydrofoils oriented perpendicular to the flow in a paddlewheel configuration. Lift and drag generated from these foils sum together to produce thrust. An experimentally tuned simulation model that solves the six-degrees-of-freedom rigid body equations of motion for the MHK vehicle subject to hydrodynamic, hydrostatic, and propulsive forces is used to aid the design of vehicle controllers. Global feedback controllers are initially designed by applying classical control methods to an approximate linear model of the system dynamics. A higher performing nonlinear controller is designed using the nonlinear dynamic inversion (NDI) method. NDI accounts for the nonlinearities of the MHK system and therefore is suitable for a wide range of operating conditions. The response of the classical and NDI controllers to speed, depth, roll, pitch, and yaw commands are evaluated and compared in simulation. The classical controller outperforms the NDI controller for small amplitude maneuvers, although the degradation with NDI is minor. However, in the nonlinear operating regime the NDI controller outperforms the classical controller and the classical controller exhibits instability.

Automation & Control Systems↗

Design and simulation of the snowflake divertor control for NSTX-U

This paper presents the development of a physics-based multiple-input-multiple-output algorithm for real-time feedback control of snowflake divertor (SFD) configurations on the National Spherical Torus eXperiment Upgrade (NSTX-U). A model of the SFD configuration response to applied voltages on the divertor control coils is first derived and then used, in conjunction with multivariable control synthesis techniques, to design an optimal state feedback controller for the configuration. To demonstrate the capabilities of the controller, a nonlinear simulator for axisymmetric shape control was developed for NSTX-U which simultaneously evolves the currents in poloidal field coils based upon a set of feedback-computed voltage commands, calculates the induced currents in passive conducting structures, and updates the plasma equilibrium by solving the free-boundary Grad-Shafranov problem. Closed-loop simulations demonstrate that the algorithm enables controlled operations in a variety of SFD configurations and provides capabilities for accurate tracking of time-dependent target trajectories for the divertor geometry. In particular, simulation results suggest that a time-varying controller which can properly account for the evolving SFD dynamical response is not only desirable but necessary for achieving acceptable control performance. The algorithm presented in this paper has been implemented in the NSTX-U Plasma Control System in preparation for future control and divertor physics experiments.

snowflake divertor, MIMO feedback control, nonline↗

Innovations in Sensors and Controls for Building Energy Management: Research and Development Opportunities Report for Emerging Technologies

Sensors, actuators, and controllers, which collectively serve as the backbone of cyberphysical systems for building energy management, are one of the core technical areas of investment for achieving the U.S. Department of Energy (DOE) Building Technologies Office's (BTO's) goals for energy affordability in the national building stock - both commercial and residential. In fact, an aggregated annual energy savings of 29% is estimated in the commercial sector alone through the implementation of efficiency measures using current state-of-the-art sensors and controls to retune buildings by optimizing programmable settings based on occupant schedules and comfort requirements, as well as detecting and diagnosing equipment operation and installation problems (Fernandez et al. 2017). Monitoring and control of building conditions and operations has advanced significantly, from the invention of the modern thermostat just before the start of the 20th century to the midcentury incorporation of direct digital control into devices, the introduction of open protocols and network communications at the end of the century, and finally the invention of cloud-based computing and additional advancements that have enabled remote operation and a proliferation of connected and intelligent devices in building automation. Despite this potential, however, two main challenges hinder widespread adoption of sensors and controls in building operations that can ensure savings for high-efficiency components and equipment (e.g., heat pumps, windows, and lighting devices), as well as additional savings from more sophisticated control architectures and algorithms. energy savings of 29% is estimated in the commercial sector alone through the implementation of efficiency measures using current state-of-the-art sensors and controls to retune buildings by optimizing programmable settings based on occupant schedules and comfort requirements, as well as detecting and diagnosing equipment operation and installation problems (Fernandez et al. 2017). Monitoring and control of building conditions and operations has advanced significantly, from the invention of the modern thermostat just before the start of the 20th century to the midcentury incorporation of direct digital control into devices, the introduction of open protocols and network communications at the end of the century, and finally the invention of cloud-based computing and additional advancements that have enabled remote operation and a proliferation of connected and intelligent devices in building automation. Despite this potential, however, two main challenges hinder widespread adoption of sensors and controls in building operations that can ensure savings for high-efficiency components and equipment (e.g., heat pumps, windows, and lighting devices), as well as additional savings from more sophisticated control architectures and algorithms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Attitude Control Approach for Solar Cruiser, a Large, Deep Space Solar Sail

Solar Cruiser is a small satellite Technology Demonstration Mission (TDM) to mature solar sail propulsion technology using a solar sail larger than 1600 square meters, demonstrating performance as a propulsion system and a stable pointing platform for science observations in an artificial halo orbit sunward of the Sun-Earth Lagrange Point 1 (sub-L1). For the “sailcraft” to meet mission ob- jectives, there are several unique attitude control challenges that the Attitude De- termination and Control System (ADCS) must overcome. Large disturbance tor- ques, primarily due to sail deformations coupled with off-sun pointing angles, make it more difficult to maintain adequate controls performance and manage accumulated momentum on the control actuators. The large-amplitude, low- frequency flexible body modes of the sail, in concert with noisy sensors and ac- tuators, make it challenging to mitigate control-structure interactions and main- tain fine pointing capabilities. Stability and control performance during sail de- ployment is complicated by rapidly and widely varying inertias. The Solar Cruiser ADCS effectively addresses these challenges using a simple, traditional control system – including momentum management actuators that use bang- bang control to constrain internal accumulated momentum, a low-pass controls filter and an attitude determination Kalman Filter (KF) that blends multiple star tracker solutions, and a reaction wheel assembly (RWA) with controller gains tuned to specific configurations or inertias. Solar Cruiser’s attitude control ap- proach, and lessons learned from its development, establishes a state of the art of high value to future solar sail missions and other small spacecraft with large de- ployable structures operating in deep space.

solar sail↗

Attitude Control Approach for Solar Cruiser, a Large, Deep Space Solar Sail

Solar Cruiser is a small satellite Technology Demonstration Mission (TDM) to mature solar sail propulsion technology using a solar sail larger than 1600 square meters, demonstrating performance as a propulsion system and a stable pointing platform for science observations in an artificial halo orbit sunward of the Sun-Earth Lagrange Point 1 (sub-L1). For the “sailcraft” to meet mission objectives, there are several unique attitude control challenges that the Attitude Determination and Control System (ADCS) must overcome. Large disturbance torques, primarily due to sail deformations coupled with off-sun pointing angles, make it more difficult to maintain adequate controls performance and manage accumulated momentum on the control actuators. The large-amplitude, low-frequency flexible body modes of the sail, in concert with noisy sensors and actuators, make it challenging to mitigate control-structure interactions and maintain fine pointing capabilities. Stability and control performance during sail deployment is complicated by rapidly and widely varying inertias. The Solar Cruiser ADCS effectively addresses these challenges using a simple, traditional control system – including momentum management actuators that use bang-bang control to constrain internal accumulated momentum, a low-pass controls filter and an attitude determination Kalman Filter (KF) that blends multiple star tracker solutions, and a reaction wheel assembly (RWA) with controller gains tuned to specific configurations or inertias. Solar Cruiser’s attitude control approach, and lessons learned from its development, establishes a state of the art of high value to future solar sail missions and other small spacecraft with large deployable structures operating in deep space.

solar sail↗

Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System: Preprint

This paper develops improved control strategy of GFM inverter with fault ride-through (FRT) capabilities to guarantee stable operation of microgrid under fault conditions especially islanded microgrid and asymmetrical faults. The proposed control strategy includes dual control of positive-sequence and negative-sequence control, and the adaptive virtual impedance (VI) control. Unlike the existing works, the proposed strategy only applies the VI control for the d-component of the positive-sequence control and leaves the q-component of positive-sequence control and dq-component of negative-sequence control zero, thus achieving the improved stability and balanced three-phase voltage under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults which could cause saturated inner current loop and instability if the VI is not adaptive. Simulation results of a phase-to-phase-ground fault show that the proposed control strategy improves the stability of GFM and achieves the stable and balanced output voltages in islanded microgrid.

fault ride-through↗

Improved Control Strategy of Grid-Forming Inverters for Fault Ride-Through in a Microgrid System

This paper develops an improved control strategy of grid-forming (GFM) inverters with fault ride-through (FRT) capabilities to guarantee the stable operation of microgrids under fault conditions, especially islanded microgrids and asymmetrical faults. The proposed control strategy includes the dual control of positive-sequence and negative-sequence control as well as the adaptive virtual impedance (VI) control. Unlike existing works, the proposed strategy applies the VI control for only the d component of the positive-sequence control and leaves the q component of the positive-sequence control and the dq component of the negative-sequence control as zero, thus achieving improved stability and balanced three-phase voltages under asymmetrical faults. The adaptive feature of the VI control guarantees the stability of the GFM inverter under severe faults, which could cause the saturation of the inner current loop, and the instability if the VI is not adaptive. Simulation results of various unbalanced faults with high and low fault impedances show that the proposed control strategy improves the stability of the GFM inverter and achieves stable and balanced output voltages in islanded microgrids. And the algorithm also improves the stability of GFM inverters under balanced faults with high and low fault impedances.

adaptive virtual impedance control↗

Energy Saving Estimation of ASHRAE Guideline 36 Supervisory Setpoint Reset Controls in a Commercial Large Office Building

Designing, commissioning, and retrofitting HVAC control systems for energy efficiency is crucial, but the use of ad-hoc control sequences by designers and contractors, based on scattered information, results in diverse and sub-optimal sequences. ASHRAE Guideline 36 (G36) addresses the challenge by providing standardized, rule-based HVAC control sequences that prioritize energy efficiency. However, there is limited evaluation of their energy performance at the building level, with only a few studies primarily focused on HVAC airside systems in small-to-medium-sized commercial buildings. In this study, the energy performance of ASHRAE Guideline 36 control sequences was assessed using a large office building emulator in Chicago. The emulator features a central plant system with multiple chillers and boilers as well as multiple variable air volume (VAV) systems with terminal reheat. To achieve a high-fidelity representation, we developed a Spawn-of-EnergyPlus-based model for the large office building, maintaining the DOE prototype large office building setup but substituting the HVAC system with its Modelica counterpart. This substitution ensures that the building thermal load, HVAC system's dynamics, and detailed control sequences are all accurately represented. The study involved evaluating and implementing control strategies outlined in ASHRAE Guideline 36-2021 to replace conventional controls. These strategies include the demand-based supply air temperature and duct static pressure setpoint reset and the request logic for demand-based reset of chilled/hot water supply temperature setpoints and pipe static pressure setpoints. Energy performance was evaluated under various load conditions, including cooling, heating, and transitional seasons, both for individual control strategies and in combination. The results indicate that the collective control strategies retrofit yield greater energy savings than the sum of individual strategies, highlighting the synergistic benefits of incorporating both airside and plant-side control retrofits. Additionally, energy savings of up to 41% in the heating season, 18% in the shoulder season, and 20 % in the cooling season were observed compared to baseline control while maintaining the thermal comfort level.

ASHRAE Guideline 36, Commercial buildings, Control↗

Utility Microgrid Controller Test Plan

The functional requirements of many microgrid controllers (MGCs) are expanding and evolving to meet growing utility and community needs. At a high level, the utility microgrid controller serves resilience and reliability use cases by coordinating transitions between grid-connected and islanded states and by managing the system during island operations. This includes control scenarios that require the microgrid controller to use flexible microgrid boundaries, maintain energy balance, coordinate with peer systems, and manage grid-forming (GFM) and grid-following (GFL) DER. In order to evaluate these functional enhancements, microgrid controller test plans must also be developed to ensure that the implemented controllers provide adequate performance. This report provides MGC test plans for both island operation and transition functions. The functions covered in this first edition report include feeder level energy management, island constraint management, secondary voltage and frequency control, black start, and synchronized reconnection. These test cases can be applied to utility-managed microgrid controllers that exclusively manage utility-owned equipment; the tests also apply to third-party managed microgrid controllers that coordinate with utility- and customer-owned equipment. The report can also be used by technology developers and project developers in industry to evaluate control strategies and performance characteristics for community microgrid controllers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of Predictive Models for Advanced Reactor Autonomous Control

Advanced reactor designs including microreactors and small modular reactors will contribute to the clean production of cheap energy, and autonomous control for advanced reactors is an appealing option for reducing cost. However, there is a lack of industry experience applying autonomous control for advanced nuclear reactors. To accelerate the development and industry acceptance of autonomous control software for nuclear reactors, we aim to demonstrate autonomous control of the Purdue University research reactor (PUR-1) using INL-developed model predictive control (MPC) methods. To prepare for this demonstration, data-driven predictive models based on process data collected from PUR-1 have been developed and integrated with MPC and used to control a physics-based model of PUR-1. A data-driven dynamics model and a gated recurrent unit (GRU) network were both trained on process data from PUR-1. The dynamics model was shown to effectively control the reactor model with MPC when provided reactivity as a control variable but failed to control the model through the control rod positions. The GRU network produced more accurate predictions than the dynamics model when evaluated on operational data, and future work will include the evaluation of the GRU network in the controller.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Coordinated Control of DFIG Based Wind Farms and SGs for Improving Transient Stability

This paper proposes a coordinated control of doubly fed induction generator (DFIG)-based wind farms' (WFs) post-fault active power and synchronous generators' (SGs) tripping with the aim of improving transient stability of both the first swing and multi swings. To achieve it, the impact mechanism of the WFs' post-fault active power and SGs' tripping on the stability margin of each swing is first presented by using extended equal area criterion (EEAC). Based on this, a principle of the coordinated control is put forward. The WFs' control period is designed as six stages, and the value of post-fault active power in each stage is suggested to improve the stability of the first five swings and maintain the post-fault steady state. To decrease the tripping amount of the SGs, the SGs are tripped only when WFs' control effect is not sufficient to avoid the instability. Then, by utilizing an “online pre-decision and real-time matching”scheme, an engineering application method for the control principle is proposed, where the control procedures and detailed parameters calculation are demonstrated. The numerical simulations show that the coordinated control has a better damping effect and a less control cost (less amount of tripped SGs) than the traditional DFIG control or traditional SG tripping.

17 WIND ENERGY↗

Application of step-response lambda tuning to proportional-integral controllers in water resource recovery facilities

Proportional-integral-derivative (PID) controllers in water resource recovery facilities (WRRFs) feedback control loops are commonplace. While simple to implement, such control loops are rarely tuned optimally or systematically. Heuristic tuning approaches are commonly applied with varying degrees of success using trial-and-error, ad hoc tuning rules, or duplication of tuning values from a similar system. However, there are effective methods, such as lambda tuning, produce acceptable tuning with limited effort. These are based on the step-response method, where a manual process perturbation is used to define the relationship between the manipulated and controlled variables. Based on such an experiment, a simple process model is constructed and used to determine the controller tuning values. In this work, we used the step-response method and lambda tuning for two control systems in full-scale WRRFs. This led to responsive and stable behavior of the controlled system as defined by the absolute average error of the controlled variable to setpoint and standard deviation of the manipulated variable. Tuning of feedback control loops can be completed successfully through a systematic approach, and this work suggests that tuning tools, like lambda, should be part of all wastewater treatment control engineers' toolbox.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Multitarget control models for building thermal comfort and indoor air quality - A critical review

The control techniques in buildings contribute significantly to thermal comfort and indoor air quality (IAQ). However, the gaps are existing for multitarget controls considering both thermal comfort and IAQ. They are: (1) both experimental and modeling control studies were conducted for thermal comfort, focusing on temperature and humidity. (2) All three (physical, grey-box, black-box) modeling approaches were investigated for temperature control. (3) Physical and grey-box modeling approach were adopted for humidity control. (4) physical models were developed for VOCs and CO2 control. (5) grey-box and black-box models were lacking for VOCs and CO2. (6) Multi-target controls were lacking for temperature, humidity and CO2s. (7) Limited studies are available for multi-target controls for temperature, humidity, and VOCs. (8) Multi-target controls are not available yet for temperature, humidity, VOCs, and CO2.

42 ENGINEERING↗

Evidence for scale‐dependent topographic controls on wildfire spread

Abstract Wildfire ecosystems are thought to be self‐regulated through pattern–process interactions between ignition frequency and location, and patterns of burned and recovering vegetation. Yet, recent increases in the frequency of large wildfires call into question the application of self‐organization theory to landscape resilience. Topography represents a stable bottom‐up template upon which fire interacts as both a physical and an ecological process. However, it is unclear how topographic control changes geographically and across spatial scales. We analyzed fire perimeter and topography data from 16 Bailey ecoregions across the State of California to identify spatial correspondence between ecoregional fire event and topographic patch size distributions. We found both sets of distributions followed a power‐law form and were statistically similar across several orders of magnitude, for most ecoregions. As a direct test of topographic controls on fire event perimeters, we used a paired t ‐test across ~11,000 fires to identify differences in topographic attributes at fire boundaries versus fire interiors. Statistical significance was determined using 500 iterations of a neutral landscape model. Level of topographic control varied significantly by ecoregion and across topographic features. For example, north–south aspect breaks, valley bottoms, and roads showed a consistently high degree of spatial control on wildfire perimeters. Topographic controls were most pronounced in mountainous ecoregions and were least influential in arid regions. Ridgetops provided a low‐level control across all ecoregions. Spatial control was strongest for small (10 0 –10 2 ha) to medium (10 3 –10 4 ha) fire sizes, suggesting that controls were scale‐dependent rather than scale‐invariant. Roads were the dominant control across all ecoregions; however, removing roads from the analyses had no significant effect on the overall role of topography on wildfire extinguishment in this analysis. This result suggested that certain topographic settings show strong spatial control on fire growth, despite the presence of roads. Our results support the observation that both bottom‐up and top‐down factors constrain fire sizes and that there are likely scaling regions within fire size distributions wherein the dominance of these spatial controls varies. Human influences on fire spread may either diminish or enhance the role of some bottom‐up and top‐down factors, adding further complexity.

Povak, Nicholas A.↗

Overshadow PLC to Detect Remote Control-Logic Injection Attacks

Programmable logic controllers (PLCs) in industrial control systems (ICS) are vulnerable to remote control logic injection attacks. Attackers target the control logic of a PLC to manipulate the behavior of a physical process such as nuclear plants, power grids, and gas pipelines. Control logic attacks have been studied extensively in the literature, including hiding the transfer of a control logic over the network from both packet header-based signatures, and deep packet inspection. For instance, these attacks transfer a control logic code as data, into small fragments (one-byte per packet), that are further padded with noise data. To detect control logic in ICS network traffic, this paper presents Shade, a novel shadow memory technique that observes the network traffic to maintain a local copy of the current state of a PLC memory. To analyze the memory contents, Shade employs a classification algorithm with 42 unique features categorized into five types at different semantic levels of a control logic code, such as number of rungs, number of consecutive decompiled instructions, and n-grams. We then evaluate Shade against control logic injection attacks on two PLCs, Modicon M221 and MicroLogix 1400 from two ICS vendors, Schneider electric and Allen-Bradley, respectively. The evaluation results show that Shade can detect an attack instance (i.e., identifying at least one attack packet during the transfer of a malicious control logic) accurately without any false alarms.

Yoo, Hyunguk↗