Search NASA⌕ Search

SEARCH · Search NASA

Results for “DISPLAY DEVICES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

SU-E-T-87: A TG-100 Approach for Quality Improvement of Associated Dosimetry Equipment

Purpose: Dosimetry protocols devote so much time to the discussion of ionization chamber choice, use and performance that is easy to forget about the importance of the associated dosimetry equipment (ADE) in radiation dosimetry - barometer, thermometer, electrometer, phantoms, triaxial cables, etc. Improper use and inaccuracy of these devices may significantly affect the accuracy of radiation dosimetry. The purpose of this study is to evaluate the risk factors in the monthly output dosimetry procedure and recommend corrective actions using a TG-100 approach. Methods: A failure mode and effects analysis (FMEA) of the monthly linac output check procedure was performed to determine which steps and failure modes carried the greatest risk. In addition, a fault tree analysis (FTA) was performed to expand the initial list of failure modes making sure that none were overlooked. After determining the failure modes with the highest risk priority numbers (RPNs), 11 physicists were asked to score corrective actions based on their ease of implementation and potential impact. The results were aggregated into an impact map to determine the implementable corrective actions. Results: Three of the top five failure modes were related to the thermometer and barometer. The two highest RPN-ranked failure modes were related to barometric pressure inaccuracy due to their high lack-of-detectability scores. Six corrective actions were proposed to address barometric pressure inaccuracy, and the survey results found the following two corrective actions to be implementable: 1) send the barometer for recalibration at a calibration laboratory and 2) check the barometer accuracy against the local airport and correct for elevation. Conclusion: An FMEA on monthly output measurements displayed the importance of ADE for accurate radiation dosimetry. When brainstorming for corrective actions, an impact map is helpful for visualizing the overall impact versus the ease of implementation.

07 ISOTOPE AND RADIATION SOURCES↗

Lunar Transport Vehicle Ocupant Protection Requirements

INTRODUCTION The National Aeronautics and Space Administration (NASA) is preparing for future Artemis missions that will return humans to the lunar surface. A critical piece of these future missions is the Lunar Transport Vehicle (LTV), a transportation device to be used on the lunar surface. A vehicular method of transportation will allow for longer duration missions with increased capabilities to conduct research and transport soil, geological samples, or other materials of interest. The objective of this project is to provide occupant protection guidance for the design of the LTV. METHODS At the time of writing of occupant protection requirements, much of the LTV design is unknown. However, several general assumptions have been established. It is assumed that the LTV will be an unpressurized crewed rover with the occupant(s) wearing an EVA suit. Additionally, the occupant must be protected using established health limits as governing criteria to protect the occupant from hazardous levels of acceleration, jerk, and vibration. In addition to the health limits, it is expected that the LTV shall provide a comfortable transportation solution to Lunar operations. Several restraint configurations have been considered to allow for seated and standing operation of the vehicle. RESULTS Preliminary recommendations and metrics were put forward by a cross functional working group with members from Johnson Space Center and Ames Research Center. Exposure to acceleration, vibration, and jerk metrics above the proposed limits could create a risk of occupant injury. In addition to satisfying crew health needs, these limits permit the occupant to meet performance objectives including operating the vehicle and reading displays while traversing the Lunar surface. Initial guidance was refined during a Technical Interchange Meeting with external subject matter experts in industry, academia, and United States Air Force. CONCLUSION Operating a crewed vehicle in a lunar environment is a novel problem with few analogs to provide data. Based on terrestrial data from ISO & MIL Standards, occupant protection recommendations have been identified with several assumptions made about reduced gravity and deconditioned occupants. If the design of the vehicle attenuates energetics to levels below those put forward, there is high confidence the occupant will be able to repetitively operate the vehicle without physical harm or operational issues.

K Dolick↗

The Role of Pentaerythritol Tetranitrate (PETN) Aging in Determining Detonator Firing Characteristics

Pentaerythritol tetranitrate (PETN) is one of the most commonly used explosives for both military and mining applications. PETN is used in EBW (exploding bridge wire) and EFI (exploding foil initiator) detonator devices. Due the widespread usage of PETN, studies focusing on how the explosive changes with age, primarily its function in detonators has received particular interest. Aging studies have identified several factors that affect PETN detonator function over time, most notably the specific surface area of the explosive powder. Though small-scale studies have been performed on specific detonator systems with isolated batches of material, what is missing is a large statistically-significant study focusing on PETN aging characteristics - such as powder coarsening - and their influence on detonator performance. Herein we report the first large statistically viable PETN aging study focusing on four batches of PETN powder from the same stock of PETN using two stabilizers, polysaccharide and TriPEON. PETN was aged both as a free-flowing powder as well as in modified EBW RP-2 detonators, for one month at 75 °C. The PETN powder has been analyzed chemically using Fisher specific surface area analysis, SEM imaging and light scattering particle size analysis. Additionally the detonators were tested for performance through voltage-sweep threshold testing and function time measurements. Findings from the study indicate that aging at 75 °C for one month significantly changes the specific surface area and particle size of unstabilized PETN, leading to increases in detonator function time, but not detonator threshold values. Powders stabilized with TriPEON displayed less significant increases in function time, while powder stabilized with polysaccharide exhibited no aging effects, despite the high temperature aging.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Monolithic Microwave Integrated Circuit (MMIC) Phased Array Demonstrated With ACTS

Monolithic Microwave Integrated Circuit (MMIC) arrays developed by the NASA Lewis Research Center and the Air Force Rome Laboratory were demonstrated in aeronautical terminals and in mobile or fixed Earth terminals linked with NASA's Advanced Communications Technology Satellite (ACTS). Four K/Ka-band experimental arrays were demonstrated between May 1994 and May 1995. Each array had GaAs MMIC devices at each radiating element for electronic beam steering and distributed power amplification. The 30-GHz transmit array used in uplinks to ACTS was developed by Lewis and Texas Instruments. The three 20-GHz receive arrays used in downlinks from ACTS were developed in cooperation with the Air Force Rome Laboratory, taking advantage of existing Air Force integrated-circuit, active-phased-array development contracts with the Boeing Company and Lockheed Martin Corporation. Four demonstrations, each related to an application of high interest to both commercial and Department of Defense organizations, were conducted. The location, type of link, and the data rate achieved for each of the applications is shown. In one demonstration-- an aeronautical terminal experiment called AERO-X--a duplex voice link between an aeronautical terminal on the Lewis Learjet and ACTS was achieved. Two others demonstrated duplex voice links (and in one case, interactive video links as well) between ACTS and an Army high-mobility, multipurpose wheeled vehicle (HMMWV, or "humvee"). In the fourth demonstration, the array was on a fixed mount and was electronically steered toward ACTS. Lewis served as project manager for all demonstrations and as overall system integrator. Lewis engineers developed the array system including a controller for open-loop tracking of ACTS during flight and HMMWV motion, as well as a laptop data display and recording system used in all demonstrations. The Jet Propulsion Laboratory supported the AERO-X program, providing elements of the ACTS Mobile Terminal. The successful performance of experimental, proof-of-concept MMIC K/Ka-band arrays developed with U.S. industry in field demonstrations with ACTS indicates that high density MMIC integration at 20 and 30 GHz is indeed feasible. The successful development and demonstration of the MMIC array systems was possible only because of significant intergovernmental and Government/industry cooperation and the high level of teamwork within Lewis. The results provide a strong incentive for continuing the focused development of MMIC-array technology for satellite communications applications, with emphasis on packaging and cost issues, and for continuing the planning and conducting of other appropriate demonstrations or experiments of phased-array technology with ACTS. Given the present pressures on reducing funding for research and development in Government and industry, the extent to which this can be continued in a cooperative manner will determine whether MMIC array technology will make the transition from the proof-of-concept level to the operational system level.

Source record↗

All‐Inorganic Bismuth‐Based Perovskite Quantum Dots with Bright Blue Photoluminescence and Excellent Stability

Abstract Lead halide perovskite quantum dots (QDs) possess color‐tunable and narrow‐band emissions and are very promising for lighting and display applications, but they suffer from lead toxicity and instability. Although lead‐free Bi‐based and Sn‐based perovskite QDs (CsSnX 3 , Cs 2 SnX 6 , and (CH 3 NH 3 ) 3 Bi 2 X 9 ) are reported, they all show low photoluminescence quantum yield (PLQY) and poor stability. Here, the synthesis of Cs 3 Bi 2 Br 9 perovskite QDs with high PLQY and excellent stability is reported. Via a green and facile process using ethanol as the antisolvent, as‐synthesized Cs 3 Bi 2 Br 9 QDs show a blue emission at 410 nm with a PLQY up to 19.4%. The whole series of Cs 3 Bi 2 X 9 (X = Cl, Br, and I) QDs by mixing precursors can cover the photoluminescence emission range from 393 to 545 nm. Furthermore, Cs 3 Bi 2 Br 9 QDs show excellent photostability and moisture stability due to the all‐inorganic nature and the surface passivation by BiOBr, which enables the one‐pot synthesis of Cs 3 Bi 2 Br 9 QD/silica composite. A lead‐free perovskite white light‐emitting diode is fabricated by simply combining the composite of Cs 3 Bi 2 Br 9 QD/silica with Y 3 Al 5 O 12 phosphor. As a new member of lead‐free perovskite QDs, Cs 3 Bi 2 Br 9 QDs open up a new route for the fabrication of optoelectronic devices due to their excellent stability and photophysical characteristics.

Leng, Meiying↗

Single Junction InGaP/GaAs Solar Cells Grown on Si Substrates using SiGe Buffer Layers

Single junction InGaP/GaAs solar cells displaying high efficiency and record high open circuit voltage values have been grown by metalorganic chemical vapor deposition on Ge/graded SiGe/Si substrates. Open circuit voltages as high as 980 mV under AM0 conditions have been verified to result from a single GaAs junction, with no evidence of Ge-related sub-cell photoresponse. Current AM0 efficiencies of close to 16% have been measured for a large number of small area cells, whose performance is limited by non-fundamental current losses due to significant surface reflection resulting from greater than 10% front surface metal coverage and wafer handling during the growth sequence for these prototype cells. It is shown that at the material quality currently achieved for GaAs grown on Ge/SiGe/Si substrates, namely a 10 nanosecond minority carrier lifetime that results from complete elimination of anti-phase domains and maintaining a threading dislocation density of approximately 8 x 10(exp 5) per square centimeter, 19-20% AM0 single junction GaAs cells are imminent. Experiments show that the high performance is not degraded for larger area cells, with identical open circuit voltages and higher short circuit current (due to reduced front metal coverage) values being demonstrated, indicating that large area scaling is possible in the near term. Comparison to a simple model indicates that the voltage output of these GaAs on Si cells follows ideal behavior expected for lattice mismatched devices, demonstrating that unaccounted for defects and issues that have plagued other methods to epitaxially integrate III-V cells with Si are resolved using SiGe buffers and proper GaAs nucleation methods. These early results already show the enormous and realistic potential of the virtual SiGe substrate approach for generating high efficiency, lightweight and strong III-V solar cells.

Ringel, S. A.↗

Improvements in electrical and dielectric properties of substituted multiferroic LaMnO{sub 3} based nanostructures synthesized by co-precipitation method

Graphical abstract: Display Omitted Highlights: ► Simultaneous double ion substitutions philosophy is introduced in LaMnO{sub 3}. ► La{sub 1−x}Gd{sub x}Mn{sub 1−y}Cr{sub y}O{sub 3} nanoparticles are not reported previously. ► La{sub 1−x}Gd{sub x}Mn{sub 1−y}Cr{sub y}O{sub 3} nanoparticles are synthesized by co-precipitation method. ► The 12 fold increase in resistivity of LaMnO{sub 3} nanostructures is observed. -- Abstract: A series of La{sub 1−x}Gd{sub x}Mn{sub 1−y}Cr{sub y}O{sub 3} nanoparticles (where x, y = 0, 0.25, 0.50, 0.75 and 1.0) has been synthesized by the chemical co-precipitation method, involving double ion substitution philosophy. The nanoparticles were characterized by thermo gravimetric analysis (TGA), X-ray fluorescence spectrometry (XRF), X-ray diffraction (XRD), scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectroscopy, vibrating sample magnetometer (VSM), DC electrical resistivity and dielectric measurements. The XRD and FTIR analysis confirmed the single orthorhombic phase and the crystallite size were found in the range of 16–34 nm. DC resistivity exhibited very interesting behavior which increased from 1.41 × 10{sup 8} to 16.35 ± 0.2 × 10{sup 8} Ω cm upon complete double ions replacement of La and Mn with Gd and Cr, respectively. This very high resistivity variation upon substitution definitely would open new avenues for applications of these materials in microwave devices and other related areas. The dielectric properties of these nanoparticles were also studied at room temperature in the range of 6 kHz to 5 MHz and the maximum dielectric behavior (ε′ = 2.86 × 10{sup 3}, tan δ = 5.41, ε″ = 15.5 × 10{sup 3}) was exhibited by La{sub 0.75}Gd{sub 0.25}Mn{sub 0.75}Cr{sub 0.25}O{sub 3} at 6 kHz. Hysteresis loops measurements showed that the synthesized nanomaterials are paramagnetic in nature at room temperature.

36 MATERIALS SCIENCE↗

SU-E-E-06: Teaching Medical Physics in a Radiology Museum

Purpose: To enhance the learning process in the teaching of medical physics by providing a venue to experience the historical equipment and devices of radiology. Methods: We have created a museum by assembling a large collection of equipment and artifacts related to radiology and medical physics. As part of a learning-in-context educational approach, classes for a survey course in medical physics are held in the museum so that students are able to visually and tangibly experience the implements of radiology, while related topics are discussed. The students learn how x-ray equipment and techniques evolved throughout the years and they learn to appreciate the differences and similarities between current x-ray technology and that of the early days. The collection contains items dating from the era of the discovery of x-rays up to recent times and includes gas x-ray tubes, hand-held fluoroscopes, generators, spark-gap kV meters, stereoscopes, glass-plate radiographs, a photofluorographic unit, wood-interspaced grid, flat-panel detector, linear-accelerator klystron, and brachytherapy radium applicators, as well as an extensive library containing some of the seminal literature of the field so that students can delve deeper into the technology. In addition to the classes, guided tours are provided for radiologic-technology, bioengineering, physics and medical students, as well as group and individual tours for the general public. Results: Student course assessments have consistently included positive expressions of their experience in the museum. Numerous students have volunteered to assist with display preparation and have learned by researching the content. Many individuals have been attracted on a walk-in basis and have expressed a deep curiosity in the technology, with positive feedback. Conclusion: The museum and its artifacts have been invaluable in stimulating interest in the history and technology of medical physics. Students and visitors alike obtain a deeper appreciation of the contribution physics has made to medicine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving Gas Reactor Design with Complex Non-Standard Reaction Mechanisms in a Reactive Flow Model

Fluorinated gases are critical to a number of high-technology industries including semiconductor manufacturing and related processes such as flat panel display, LED, and photovoltaic manufacturing. These fluorinated gases have very high global warming potentials (GWPs) and, unfortunately are chemically very stable, in some cases lasting for thousands of years in the atmosphere. For environmental reasons, it is imperative that the release of these gases be minimized, but existing methods to destroy them requires a significant amount of energy. The goal of this project was to develop a more energy efficient method of destroying these high GWP gases using computational fluid dynamics, but the computational requirements are significant. In this project, we bring together resources available at the national labs, including high-performance computing hardware and modern computational methods, in order to explore an industrially important problem with key environmental and economic impact. In this project, we examined the state-of-the-art models for the physical processes involved, and made subtle changes to arrive at alternative formulations considerably better suited for computation and study. We examined several representative scenarios and developed a set of analyses techniques and tools that could be used to explore the systems in much greater detail. This exploratory project has demonstrated to ALZETA that HPC can indeed provide a unique view into their complex engineering problem - one that is simply inaccessible by any other means. The tools allow us to explore the details of the chemical process, and allow one to construct "what-if" scenarios to address shortcomings of the physical device in its current operating modes. However, as with many sources of completely new information, many new questions are illuminated with this capability. It will take considerable time, effort and experience before we learn to probe the solutions, pose operating scenarios and confirm modifications to the device that lead to real engineering advances.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Theodolite with CCD Camera for Safe Measurement of Laser-Beam Pointing

The simple addition of a charge-coupled-device (CCD) camera to a theodolite makes it safe to measure the pointing direction of a laser beam. The present state of the art requires this to be a custom addition because theodolites are manufactured without CCD cameras as standard or even optional equipment. A theodolite is an alignment telescope equipped with mechanisms to measure the azimuth and elevation angles to the sub-arcsecond level. When measuring the angular pointing direction of a Class ll laser with a theodolite, one could place a calculated amount of neutral density (ND) filters in front of the theodolite s telescope. One could then safely view and measure the laser s boresight looking through the theodolite s telescope without great risk to one s eyes. This method for a Class ll visible wavelength laser is not acceptable to even consider tempting for a Class IV laser and not applicable for an infrared (IR) laser. If one chooses insufficient attenuation or forgets to use the filters, then looking at the laser beam through the theodolite could cause instant blindness. The CCD camera is already commercially available. It is a small, inexpensive, blackand- white CCD circuit-board-level camera. An interface adaptor was designed and fabricated to mount the camera onto the eyepiece of the specific theodolite s viewing telescope. Other equipment needed for operation of the camera are power supplies, cables, and a black-and-white television monitor. The picture displayed on the monitor is equivalent to what one would see when looking directly through the theodolite. Again, the additional advantage afforded by a cheap black-and-white CCD camera is that it is sensitive to infrared as well as to visible light. Hence, one can use the camera coupled to a theodolite to measure the pointing of an infrared as well as a visible laser.

Crooke, Julie A.↗

Optical Multi-Gas Monitor Technology Demonstration on the International Space Station

There are a variety of both portable and fixed gas monitors onboard the International Space Station (ISS). Devices range from rack-mounted mass spectrometers to hand-held electrochemical sensors. An optical Multi-Gas Monitor has been developed as an ISS Technology Demonstration to evaluate long-term continuous measurement of 4 gases. Based on tunable diode laser spectroscopy, this technology offers unprecedented selectivity, concentration range, precision, and calibration stability. The monitor utilizes the combination of high performance laser absorption spectroscopy with a rugged optical path length enhancement cell that is nearly impossible to misalign. The enhancement cell serves simultaneously as the measurement sampling cell for multiple laser channels operating within a common measurement volume. Four laser diode based detection channels allow quantitative determination of ISS cabin concentrations of water vapor (humidity), carbon dioxide, ammonia and oxygen. Each channel utilizes a separate vertical cavity surface emitting laser (VCSEL) at a different wavelength. In addition to measuring major air constituents in their relevant ranges, the multiple gas monitor provides real time quantitative gaseous ammonia measurements between 5 and 20,000 parts-per-million (ppm). A small ventilation fan draws air with no pumps or valves into the enclosure in which analysis occurs. Power draw is only about 3 W from USB sources when installed in Nanoracks or when connected to 28V source from any EXPRESS rack interface. Internal battery power can run the sensor for over 20 hours during portable operation. The sensor is controlled digitally with an FPGA/microcontroller architecture that stores data internally while displaying running average measurements on an LCD screen and interfacing with the rack or laptop via USB. Design, construction and certification of the Multi-Gas Monitor were a joint effort between Vista Photonics, Nanoracks and NASA-Johnson Space Center (JSC). Vista Photonics developed the core technology and built the sensor. Nanoracks designed, constructed the enclosure, interfaces, and battery power management circuitry, integrated all subsystems into the enclosure, and then managed the certification tests, documentation and manifesting. The unit was calibrated in the JSC Toxicology Laboratory. The Multi-Gas Monitor is manifested to fly as a technology demonstration to the ISS in November 2013 and will operate for at least 6 months with data sent to the ground for evaluation. The primary goal is to demonstrate long term interference free operation in the real spacecraft environment.

Pilgrim, Jeffrey S.↗

Toroidally Resolved Structure of Divertor Heat Flux in RMP H-mode Discharges on DIII-D

As shown on DIII-D edge localized modes (ELMs) can be either completely eliminated or mitigated with resonant magnetic perturbation (RMP) fields. Two infrared cameras, separated 105 degrees toroidally, were used to make simultaneous measurements of ELM heat loads with high frame rates. Without the RMP fields ELMs display a variety of different heat load dynamics and a range of toroidal variability that is characteristic of their 3D structure. Comparing radial averages there is no asymmetry between two toroidal locations. With RMP-mitigated ELMs, the variability in the radially averaged power loads is significantly reduced and toroidal asymmetries in power loads are introduced. In addition to RMP ELM suppression scenarios an RMP scenario with only very small ELMs and very good confinement has been achieved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A perspective on two-dimensional van der Waals opto-spin-caloritronics

Two-dimensional (2D) van der Waals magnetic semiconductors displaying controllable ferromagnetism at room temperature form atomically sharp interfaces with various substrates. Such heterostructures create platforms for understanding spin-dependent phenomena across interfaces and surfaces for high-performance technological applications. Combining these 2D magnets with light and the spin Seebeck effect (SSE) in-state-of-the-art thermo-opto-spin studies forms a new paradigm in the field of spin-caloritronics that harnesses light as the new heat. In this Perspective, we detail how to exploit recent advances in 2D van der Waals materials to boost the SSE and propose a new strategy for optically controlled SSE in 2D magnetic semiconductor-based heterostructures with the intent to establish the research thrust of “opto-spin-caloritronics.”

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

α-Quartz Phase Stabilization, Surface Texturing, and Tunable Optical Properties of Nanocrystalline GeO 2 Films Made by Pulsed-Laser Deposition: Implications for Optical and Optoelectronic Applications

Germanium oxide (GeO 2 ) has great potential in multifunctional devices and next-generation power electronics due to its high thermal conductivity and ambipolar doping capability. However, the complexity of synthesizing the desirable polymorph with a controlled phase, surface/interface quality, microstructure, and functional properties is the main barrier to GeO 2 utilization in advanced applications. Here, in this regard, we present a method to realize the hexagonal (h) or a-quartz type GeO 2 with nano-textured surface morphology on sapphire substrates using a hybrid synthesis strategy that comprises pulsed laser deposition (PLD) and post-deposition thermal annealing. We performed a comprehensive study to investigate the effect of annealing temperature, which was varied in a wide range (600-1100 °C), on the crystal structure, phase, surface morphology, chemical stoichiometry, defect states, and optical properties of PLD-grown GeO 2 films. As-deposited GeO 2 films at 500 °C were amorphous. Upon annealing, the GeO 2 films induced an amorphous-to-crystalline phase transformation; GeO 2 films annealed at higher annealing temperatures (≥900 °C) stabilized in the hexagonal phase and demonstrated excellent crystal quality and chemical stability. Thermally activated growth process showed increased average crystallite size, which was varied in the range of 20-130 (±2) nm, while the surface roughness followed a similar trend. The spectral transmittance and band gap also increased with increasing annealing temperature. The resulting h-GeO 2 films, particularly those obtained at annealing temperatures in the 900-1100 °C range, had a higher band gap of 6.2-6.3 eV and displayed excellent optical transmittance in the visible region. Moreover, the absence of extended valence band maxima and reduced optical defect density support the quality improvement upon annealing. When considering phase-pure bulk and nanostructured GeO 2 as a possible candidate for ultra wide band gap semiconductors in cutting-edge technological applications, the results of the current work can be beneficial to realize high structural and optical quality a-quartz structured GeO 2 films.

GeO2↗

Exploring the Light-induced Dynamics in Solvated Metallogrid Complexes with Femtosecond Pulses Across the Electromagnetic Spectrum

Oligonuclear complexes of d 4 -d 7 transition metal ion centers that undergo spin-switching have long been developed for their practical role in molecular electronics. Recently, they also have appeared as promising photochemical reactants demonstrating improved stability. However, the lack of knowledge about their photophysical properties in the solution phase compared to their mononuclear congeners is currently hampering their inclusion into advanced light-driven reactions. In the present study, the ultrafast photoinduced dynamics in a solvated [2x2] iron(II) metallogrid complex are characterized by combining transient optical, infrared absorption and X-ray emission spectroscopic measurements on the femtosecond timescale. The analysis is supported by DFT calculations. The photocycle can be described in terms of intra-site transitions, where the Fe II in the low-spin (LS) state are independently photoexcited. The Franck-Condon state decays via the formation of a vibrationally-hot high-spin (HS) state that displays coherent behavior within a few picoseconds and thermalizes within tens of picosecond to yield a metastable HS state living for several hundreds of nanoseconds. Additionally, systematic comparison with the closely related mononuclear complex [Fe(terpy) 2 ] 2+ reveals that nuclearity has a profound impact on the photoinduced dynamics. Finally, this work provides guidelines for expanding the integration of oligonuclear complexes into new photoconversion schemes that may be triggered by ultrafast spin-switching.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characteristics and performance of the first commercial multileaf collimator for a robotic radiosurgery system

Purpose: The “InCise™ multileaf-collimator (MLC)” is the first commercial MLC to be mounted on a robotic SRS/SBRT platform (CyberKnife). The authors assessed characteristics and performance of this novel device in a preclinical five months test period. Methods: Commissioning beam data were acquired with unshielded diodes. EBT3 radiochromic films were employed for measurement of transmission, leaf/bank position accuracy (garden fence) before and after exercising the MLC, for end-to-end testing and further characterization of the beam. The robot workspace with MLC was assessed analytically by transformation to an Euler geometry (“plane,” “gantry,” and “collimator” angles) and by measuring pointing accuracy at each node. Stability over time was evaluated in picket fence and adapted Winston–Lutz tests (AQA). Results: Beam penumbrae (80%–20%, with 100% = 2 × dose at inflection point for field sizes ≥ 50 × 50 mm{sup 2}) were 2.2–3.7 mm for square fields in reference condition (source-axis-distance 800 mm, depth 15 mm) and depended on field size and off-axis position. Transmission and leakage did not exceed 0.5%. Accessible clinical workspace with MLC covered non-coplanar gantry angles of [−113°; +112°] and collimator angles of [−100°; +107°], with an average robot pointing accuracy of 0.12 ± 0.09 mm. For vertical beams, garden fence tests exhibited an average leaf positioning error of ≤0.2 mm, which increased by 0.25 and 0.30 mm (banks X1 and X2) with leaves traveling parallel to gravity. After execution of a leaf motion stress routine, garden fence tests showed slightly increased jaggedness and allowed to identify one malfunctioning leaf motor. Total system accuracy with MLC was 0.38 ± 0.05 mm in nine end-to-end tests. Picket fence and AQA tests displayed stable results over the test period. Conclusions: The InCise™ MLC for CyberKnife showed high accuracy and adequate characteristics for SRS/SBRT applications. MLC performance after exercise demands specific quality assurance measures.

60 APPLIED LIFE SCIENCES↗

Electronic and thermal properties of the phase-change memory material, Ge 2 Sb 2 Te 5 , and results from spatially resolved transport calculations

Here, we report new insights into the electronic, structural, and transport (heat and charge) properties of the phase-change memory material amorphous Ge 2 Sb 2 Te 5 . Using realistic structural models of Konstantinou et al., (2019), we analyze the topology, electronic states, and lattice dynamics with density functional methods, including hybrid-functional calculations and machine-learned interatomic potentials. The Kohn–Sham orbitals near the Fermi level display a strong electron–phonon coupling, and exhibit large energy fluctuations at room temperature. The conduction tail states exhibit larger phonon-induced fluctuations than the valence tail states. To resolve transport at the atomic scale, we employ space-projected electronic conductivity and site-projected thermal conductivity methods. Local analysis of heat transport highlights the role of filamentary networks dominated by Te, with Sb and Ge making progressively smaller contributions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Algorithms for High-Speed Noninvasive Eye-Tracking System

Two image-data-processing algorithms are essential to the successful operation of a system of electronic hardware and software that noninvasively tracks the direction of a person s gaze in real time. The system was described in High-Speed Noninvasive Eye-Tracking System (NPO-30700) NASA Tech Briefs, Vol. 31, No. 8 (August 2007), page 51. To recapitulate from the cited article: Like prior commercial noninvasive eyetracking systems, this system is based on (1) illumination of an eye by a low-power infrared light-emitting diode (LED); (2) acquisition of video images of the pupil, iris, and cornea in the reflected infrared light; (3) digitization of the images; and (4) processing the digital image data to determine the direction of gaze from the centroids of the pupil and cornea in the images. Most of the prior commercial noninvasive eyetracking systems rely on standard video cameras, which operate at frame rates of about 30 Hz. Such systems are limited to slow, full-frame operation. The video camera in the present system includes a charge-coupled-device (CCD) image detector plus electronic circuitry capable of implementing an advanced control scheme that effects readout from a small region of interest (ROI), or subwindow, of the full image. Inasmuch as the image features of interest (the cornea and pupil) typically occupy a small part of the camera frame, this ROI capability can be exploited to determine the direction of gaze at a high frame rate by reading out from the ROI that contains the cornea and pupil (but not from the rest of the image) repeatedly. One of the present algorithms exploits the ROI capability. The algorithm takes horizontal row slices and takes advantage of the symmetry of the pupil and cornea circles and of the gray-scale contrasts of the pupil and cornea with respect to other parts of the eye. The algorithm determines which horizontal image slices contain the pupil and cornea, and, on each valid slice, the end coordinates of the pupil and cornea. Information from multiple slices is then combined to robustly locate the centroids of the pupil and cornea images. The other of the two present algorithms is a modified version of an older algorithm for estimating the direction of gaze from the centroids of the pupil and cornea. The modification lies in the use of the coordinates of the centroids, rather than differences between the coordinates of the centroids, in a gaze-mapping equation. The equation locates a gaze point, defined as the intersection of the gaze axis with a surface of interest, which is typically a computer display screen (see figure). The expected advantage of the modification is to make the gaze computation less dependent on some simplifying assumptions that are sometimes not accurate

Talukder, Ashit↗