Actions to Evaluate Tritium in ATR Complex Perched Water Well 12
On April 23, 2019, elevated tritium concentrations in monitoring well PW-12 were reported to the Advanced Test Reactor (ATR) Complex environmental manager by the Fluor Idaho Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA) lead. The monitoring well is one of a series of wells located in and around the ATR Complex that are sampled on an annual basis as part of the CERCLA monitoring program. The Fluor Idaho CERCLA lead indicated the elevated concentrations had been trending upward from Fiscal Year (FY) 2017 through FY 2019. The tritium levels went from 1,880 pCi/L in October 2016 to 7,890 pCi/L in October 2017 and increased to 13,000 pCi/L in October 2018. In order to identify a baseline, the safe drinking water level (e.g. 20,000 pCi/L) can be used as a reference point for comparison only, as PW-12 is a perched water well and does not penetrate the aquifer. Although well below safe drinking water levels, an investigation was initiated to identify the source of tritium.