Search NASA⌕ Search

SEARCH · Search NASA

Results for “Field Procedures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Quantum rotor in nanostructured superconductors

Despite its apparent simplicity, the idealized model of a particle constrained to move on a circle has intriguing dynamic properties and immediate experimental relevance. While a rotor is rather easy to set up classically, the quantum regime is harder to realize and investigate. Here we demonstrate that the quantum dynamics of quasiparticles in certain classes of nanostructured superconductors can be mapped onto a quantum rotor. Furthermore, we provide a straightforward experimental procedure to convert this nanoscale superconducting rotor into a regular or inverted quantum pendulum with tunable gravitational field, inertia, and drive. We detail how these novel states can be detected via scanning tunneling spectroscopy. The proposed experiments will provide insights into quantum dynamics and quantum chaos.

36 MATERIALS SCIENCE↗

Analyzing the threat of unmanned aerial vehicles (UAV) to nuclear facilities

Unmanned aerial vehicles (UAV) are among the major growing technologies that have many beneficial applications, yet they can also pose a significant threat. Recently, several incidents occurred with UAVs violating privacy of the public and security of sensitive facilities, including several nuclear power plants in France. The threat of UAVs to the security of nuclear facilities is of great importance and is the focus of this work. This paper presents an overview of UAV technology and classification, as well as its applications and potential threats. We show several examples of recent security incidents involving UAVs in France, USA, and United Arab Emirates. Further, the potential threats to nuclear facilities and measures to prevent them are evaluated. The importance of measures for detection, delay, and response (neutralization) of UAVs at nuclear facilities are discussed. An overview of existing technologies along with their strength and weaknesses are shown. Finally, the results of a gap analysis in existing approaches and technologies is presented in the form of potential technological and procedural areas for research and development. Furthermore based on this analysis, directions for future work in the field can be devised and prioritized.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Optimization of in-line phase contrast particle image velocimetry using a laboratory x-ray source

Phase contrast particle image velocimetry (PIV) using a laboratory x-ray microfocus source is investigated using a numerical model. Phase contrast images of 75 {mu}m air bubbles, embedded within water exhibiting steady-state vortical flow, are generated under the paraxial approximation using a tungsten x-ray spectrum at 30 kVp. Propagation-based x-ray phase-contrast speckle images at a range of source-object and object-detector distances are generated, and used as input into a simulated PIV measurement. The effects of source-size-induced penumbral blurring, together with the finite dynamic range of the detector, are accounted for in the simulation. The PIV measurement procedure involves using the cross-correlation between temporally sequential speckle images to estimate the transverse displacement field for the fluid. The global error in the PIV reconstruction, for the set of simulations that was performed, suggests that geometric magnification is the key parameter for designing a laboratory-based x-ray phase-contrast PIV system. For the modeled system, x-ray phase-contrast PIV data measurement can be optimized to obtain low error (<0.2 effective pixel of the detector) in the system with magnification lying in the range between 1.5 and 3. For large effective pixel size (>15 {mu}m) of the detector, high geometric magnification (>2.5) is desired, while for large source size system (FWHM > 30 {mu}m), low magnification (<1.5) would be suggested instead. The methods developed in this paper can be applied to optimizing phase-contrast velocimetry using a variety of laboratory x-ray sources.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ultra-fast photon counting with a passive quenching silicon photomultiplier in the charge integration regime

An ultra-fast photon counting method is proposed based on the charge integration of output electrical pulses of passive quenching silicon photomultipliers (SiPMs). The results of the numerical analysis with actual parameters of SiPMs show that the maximum photon counting rate of a state-of-art passive quenching SiPM can reac ∼ THz levels which is much larger than that of the existing photon counting devices. The experimental procedure is proposed based on this method. This photon counting regime of SiPMs is promising in many fields such as large dynamic light power detection. (photon detectors)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SPITZER MIPS 24 and 70 {mu}m IMAGING NEAR THE SOUTH ECLIPTIC POLE: MAPS AND SOURCE CATALOGS

We have imaged an 11.5 deg{sup 2} region of sky toward the South Ecliptic Pole (R.A. =04{sup h}43{sup m}, decl. =-53{sup 0}40', J2000) at 24 and 70 {mu}m with MIPS, the Multiband Imaging Photometer for Spitzer. This region is coincident with a field mapped at longer wavelengths by AKARI and BLAST. We discuss our data reduction and source extraction procedures. The median 1{sigma} depths of the maps are 47 {mu}Jy beam{sup -1} at 24 {mu}m and 4.3 mJy beam{sup -1} at 70 {mu}m. At 24 {mu}m, we identify 93,098 point sources with signal-to-noise ratio (S/N) {>=}5 and an additional 63 resolved galaxies; at 70 {mu}m we identify 891 point sources with S/N {>=}6. From simulations, we determine a false detection rate of 1.8% (1.1%) for the 24 {mu}m (70 {mu}m) catalog. The 24 and 70 {mu}m point-source catalogs are 80% complete at 230 {mu}Jy and 11 mJy, respectively. These mosaic images and source catalogs will be available to the public through the NASA/IPAC Infrared Science Archive.

79 ASTRONOMY AND ASTROPHYSICS↗

Cosmological matching conditions and galilean genesis in Horndeski's theory

We derive the cosmological matching conditions for the homogeneous and isotropic background and for linear perturbations in Horndeski's most general second-order scalar-tensor theory. In general relativity, the matching is done in such a way that the extrinsic curvature is continuous across the transition hypersurface. This procedure is generalized so as to incorporate the mixing of scalar and gravity kinetic terms in the field equations of Horndeski's theory. Our matching conditions have a wide range of applications including the galilean genesis and the bounce scenarios, in which stable, null energy condition violating solutions play a central role. We demonstrate how our matching conditions are used in the galilean genesis scenario. In doing so, we extend the previous genesis models and provide a unified description of the theory admitting the solution that starts expanding from the Minkowski spacetime.

79 ASTRONOMY AND ASTROPHYSICS↗

*-DCC: A platform to collect, annotate, and explore a large variety of sequencing experiments

Background: Over the past few years the variety of experimental designs and protocols for sequencing experiments increased greatly. To ensure the wide usability of the produced data beyond an individual project, rich and systematic annotation of the underlying experiments is crucial. Findings: We first developed an annotation structure that captures the overall experimental design as well as the relevant details of the steps from the biological sample to the library preparation, the sequencing procedure, and the sequencing and processed files. Through various design features, such as controlled vocabularies and different field requirements, we ensured a high annotation quality, comparability, and ease of annotation. The structure can be easily adapted to a large variety of species. We then implemented the annotation strategy in a user-hosted web platform with data import, query, and export functionality. Conclusions: We present here an annotation structure and user-hosted platform for sequencing experiment data, suitable for lab-internal documentation, collaborations, and large-scale annotation efforts.

59 BASIC BIOLOGICAL SCIENCES↗

Atomic interferometer measurements of Berry and Aharonov-Anandan phases for isolated spins S>(1/2) nonlinearly coupled to external fields

In a recent paper we have studied the peculiar features of the Berry and Aharonov-Anandan geometric phases for isolated spins S{>=}1. We have assumed that they are submitted to a dipole and quadrupole coupling to external E and B fields with the mild restriction E{center_dot}B=0. This implies discrete symmetries leading to remarkable simplifications of the geometry and algebra involved. The aim of the present work is to describe realistic proposals, within the realm of atomic physics, for the verification of some of our most significant theoretical predictions. There are several challenges to be overcome. For alkali-metal atoms, most commonly used in atomic interferometers, the only practical way to generate quadrupole coupling, with a strength comparable to the dipole one, is the ac Stark effect induced by a nearly resonant light beam. One then has to face the instability of the 'dressed' atom hyperfine (hf) level, a candidate for our isolated spin. One deleterious effect is the apparition of an imaginary part in the quadrupole to dipole coupling strength ratio, {lambda}. Fortunately we have found a simple way to get rid of I({lambda}) by an appropriate detuning. We are left with an unstable isolated spin. This implies an upper bound to the quantum cycle duration T{sub c}. In the case of the Berry's phase, T{sub c} has a lower bound due to the necessity of keeping the nonadiabatic corrections below a predefined level. We have found a compromise in the case of the F=2,m=0 {sup 87}Rb ground-state hf level. This is our candidate for the measurement of the somewhat ''exotic'' Berry's phase acquired by the S=2,m=0 state at the end of a quantum cycle involving a rotation of {pi} of the E field--in practice, the linear polarization of the dressing beam --about the B field direction. We have found a way to implement, in a Ramsey-type interferometric measurement, the procedures aimed at controlling the nonadiabatic corrections, as described in detail in our previous theoretical paper. A numerical simulation of our experimental proposal shows that a 0.1% accurate determination of Berry's phase, free of nonadiabatic corrections, can be achieved. Measurements could also be considered for cold {sup 52}Cr chromium atoms with S=3, where values of {lambda}{approx_equal}1 can be obtained with an instability smaller than in the {sup 87}Rb case, due to a more favorable spectroscopic structure. The F=1,m=1 hf level of the {sup 87}Rb ground state offers the opportunity to extend the measurement of Aharonov-Anandan's phases beyond the case S=(1/2). We construct, using 'light shift', the Hamiltonian H{sub ||}(t) generating a closed circuit in the density-matrix space which satisfies at any time the 'parallel transport' condition, thus making the quantum cycle free from the adiabaticity condition. We also consider the case of half-integer spins (e.g., {sup 201}Hg, {sup 135}Ba, and {sup 137}Ba), with their own specific features. We show how the difference of Berry's phases for states S=(3/2) and S=(1/2), with m=(1/2), can be exploited to achieve a holonomic maximum entanglement of three qubits.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Comment on &#x27;Precision global measurements of London penetration depth in FeTe0.58Se0.42&#x27;

We reply to the Comment by Klein, Rodière, and Marcenat [ Phys. Rev. B 86 066501 (2012)] on our paper [ Phys. Rev. B 84 174502 (2011)]. Our work was motivated by Klein et al. [ Phys. Rev. B 82 184506 (2010)]. In their paper, Klein et al. have attributed a factor of 5 difference in the value of the London penetration depth obtained from their tunnel diode resonator (TDR) measurements and calculated from the “field of first penetration”to the surface roughness, although they have not verified it experimentally. In our paper, we have studied the effects of deliberately introduced surface roughness and found that its effects are minor and cannot be responsible for the difference of such magnitude. Instead, we suggest that the value of the field of first penetration measured with Hall arrays cannot be used to extract a true lower critical field due to several reasons outlined in our Reply. We emphasize that the accuracy of the calibration procedure of the TDR technique has been carefully verified in several prior studies and our work on FeTe0.58Se0.42 further confirms it. We show that in their Comment, Klein et al. use wrong arguments of the universal behavior of the superfluid density in the gapless limit, because it is inapplicable for the multiband superconductors. We also discuss the applicability of the clean-limit γ model and the influence of the disorder on the obtained results.

36 MATERIALS SCIENCE↗

Five-analyzer Johann spectrometer for hard X-ray photon-in/photon-out spectroscopy at the Inner Shell Spectroscopy beamline at NSLS-II: design, alignment and data acquisition

Here, a recently commissioned five-analyzer Johann spectrometer at the Inner Shell Spectroscopy beamline (8-ID) at the National Synchrotron Light Source II (NSLS-II) is presented. Designed for hard X-ray photon-in/photon-out spectroscopy, the spectrometer achieves a resolution in the 0.5–2 eV range, depending on the element and/or emission line, providing detailed insights into the local electronic and geometric structure of materials. It serves a diverse user community, including fields such as physical, chemical, biological, environmental and materials sciences. This article details the mechanical design, alignment procedures and data-acquisition scheme of the spectrometer, with a particular focus on the continuous asynchronous data-acquisition approach that significantly enhances experimental efficiency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning and dosimetric characteristics of TrueBeam system: Composite data of three TrueBeam machines

Purpose: A TrueBeam linear accelerator (TB-LINAC) is designed to deliver traditionally flattened and flattening-filter-free (FFF) beams. Although it has been widely adopted in many clinics for patient treatment, limited information is available related to commissioning of this type of machine. In this work, commissioning data of three units were measured, and multiunit comparison was presented to provide valuable insights and reliable evaluations on the characteristics of the new treatment system. Methods: The TB-LINAC is equipped with newly designed waveguide, carousel assembly, monitoring control, and integrated imaging systems. Each machine in this study has 4, 6, 8, 10, 15 MV flattened photon beams, and 6 MV and 10 MV FFF photon beams as well as 6, 9, 12, 16, 20, and 22 MeV electron beams. Dosimetric characteristics of the three new TB-LINAC treatment units are systematically measured for commissioning. High-resolution diode detectors and ion chambers were used to measure dosimetric data for a range of field sizes from 10 Multiplication-Sign 10 to 400 Multiplication-Sign 400 mm{sup 2}. The composite dosimetric data of the three units are presented in this work. The commissioning of intensity modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT), image-guided radiation therapy, and gating systems are also illustrated. Critical considerations of P{sub ion} of FFF photon beams and small field dosimetric measurements were investigated. Results: The authors found all PDDs and profiles matched well among the three machines. Beam data were quantitatively compared and combined through average to yield composite beam data. The discrepancies among the machines were quantified using standard deviation (SD). The mean SD of the PDDs among the three units is 0.12%, and the mean SD of the profiles is 0.40% for 10 MV FFF open fields. The variations of P{sub ion} of the chamber CC13 is 1.2 {+-} 0.1% under 6 MV FFF and 2.0 {+-} 0.5% under 10 MV FFF from dmax to the 18 cm-off-axis point at 35 cm depth under 40 Multiplication-Sign 40 cm{sup 2}. The mean penumbra of crossplane flattened photon beams at collimator angle of 0 Degree-Sign is measured from 5.88 {+-} 0.09 to 5.99 {+-} 0.13 mm from 4 to 15 MV at 10 cm depth of 100 Multiplication-Sign 100 mm{sup 2}. The mean penumbra of crossplane beams at collimator angle of 0 Degree-Sign is measured as 3.70 {+-} 0.21 and 4.83 {+-} 0.04 mm for 6 MV FFF and 10 MV FFF, respectively, at 10 cm depth with a field size of 5 Multiplication-Sign 5 cm{sup 2}. The end-to-end test procedures of both IMRT and VMAT were performed for various energy modes. The mean ion chamber measurements of three units showed less than 2% between measurement and calculation; the mean MultiCube ICA measurements demonstrated over 90% pixels passing gamma analysis (3%, 3 mm, 5% threshold). The imaging dosimetric data of KV planar imaging and CBCT demonstrated improved consistency with vendor specifications and dose reduction for certain imaging protocols. The gated output verification showed a discrepancy of 0.05% or less between gating radiation delivery and nongating radiation delivery. Conclusions: The commissioning data indicated good consistency among the three TB-LINAC units. The commissioning data provided us valuable insights and reliable evaluations on the characteristics of the new treatment system. The systematically measured data might be useful for future reference.

07 ISOTOPE AND RADIATION SOURCES↗

Improving best-phase image quality in cardiac CT by motion correction with MAM optimization

Purpose: Research in image reconstruction for cardiac CT aims at using motion correction algorithms to improve the image quality of the coronary arteries. The key to those algorithms is motion estimation, which is currently based on 3-D/3-D registration to align the structures of interest in images acquired in multiple heart phases. The need for an extended scan data range covering several heart phases is critical in terms of radiation dose to the patient and limits the clinical potential of the method. Furthermore, literature reports only slight quality improvements of the motion corrected images when compared to the most quiet phase (best-phase) that was actually used for motion estimation. In this paper a motion estimation algorithm is proposed which does not require an extended scan range but works with a short scan data interval, and which markedly improves the best-phase image quality. Methods: Motion estimation is based on the definition of motion artifact metrics (MAM) to quantify motion artifacts in a 3-D reconstructed image volume. The authors use two different MAMs, entropy, and positivity. By adjusting the motion field parameters, the MAM of the resulting motion-compensated reconstruction is optimized using a gradient descent procedure. In this way motion artifacts are minimized. For a fast and practical implementation, only analytical methods are used for motion estimation and compensation. Both the MAM-optimization and a 3-D/3-D registration-based motion estimation algorithm were investigated by means of a computer-simulated vessel with a cardiac motion profile. Image quality was evaluated using normalized cross-correlation (NCC) with the ground truth template and root-mean-square deviation (RMSD). Four coronary CT angiography patient cases were reconstructed to evaluate the clinical performance of the proposed method. Results: For the MAM-approach, the best-phase image quality could be improved for all investigated heart phases, with a maximum improvement of the NCC value by 100% and of the RMSD value by 81%. The corresponding maximum improvements for the registration-based approach were 20% and 40%. In phases with very rapid motion the registration-based algorithm obtained better image quality, while the image quality of the MAM algorithm was superior in phases with less motion. The image quality improvement of the MAM optimization was visually confirmed for the different clinical cases. Conclusions: The proposed method allows a software-based best-phase image quality improvement in coronary CT angiography. A short scan data interval at the target heart phase is sufficient, no additional scan data in other cardiac phases are required. The algorithm is therefore directly applicable to any standard cardiac CT acquisition protocol.

60 APPLIED LIFE SCIENCES↗

SU-E-T-195: Gantry Angle Dependency of MLC Leaf Position Error

Purpose: The aim of this study was to investigate the gantry angle dependency of the multileaf collimator (MLC) leaf position error. Methods: An automatic MLC quality assurance system (AutoMLCQA) was developed to evaluate the gantry angle dependency of the MLC leaf position error using an electronic portal imaging device (EPID). To eliminate the EPID position error due to gantry rotation, we designed a reference maker (RM) that could be inserted into the wedge mount. After setting up the EPID, a reference image was taken of the RM using an open field. Next, an EPID-based picket-fence test (PFT) was performed without the RM. These procedures were repeated at every 45° intervals of the gantry angle. A total of eight reference images and PFT image sets were analyzed using in-house software. The average MLC leaf position error was calculated at five pickets (-10, -5, 0, 5, and 10 cm) in accordance with general PFT guidelines using in-house software. This test was carried out for four linear accelerators. Results: The average MLC leaf position errors were within the set criterion of <1 mm (actual errors ranged from -0.7 to 0.8 mm) for all gantry angles, but significant gantry angle dependency was observed in all machines. The error was smaller at a gantry angle of 0° but increased toward the positive direction with gantry angle increments in the clockwise direction. The error reached a maximum value at a gantry angle of 90° and then gradually decreased until 180°. In the counter-clockwise rotation of the gantry, the same pattern of error was observed but the error increased in the negative direction. Conclusion: The AutoMLCQA system was useful to evaluate the MLC leaf position error for various gantry angles without the EPID position error. The Gantry angle dependency should be considered during MLC leaf position error analysis.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-T-76: Total Skin Electron Therapy: An-End-To-End Examination of the Absolute Dosimetry with a Rando Phantom

Purpose: To examine and validate the absolute dose for total skin electron therapy (TSET) through an end-to-end test with a Rando phantom using optically stimulated luminescent dosimeters (OSLDs) and EBT3 radiochromic films. Methods: A Varian Trilogy linear accelerator equipped with the special procedure 6 MeV HDTSe- was used to perform TSET irradiations using a modified Stanford 6-dual-field technique. The absolute dose was calibrated using a Markus ion chamber at a reference depth of 1.3cm at 100 cm SSD with a field size of 36 × 36 cm at the isocenter in solid water slabs. The absolute dose was cross validated by a farmer ion chamber. Then the dose rate in the unit of cGy/Mu was calibrated using the Markus chamber at the treatment position. OSLDs were used to independently verify the dose using the calibrated dose rate. Finally, a patient treatment plan (200 cGy/cycle) was delivered in the QA mode to a Rando phantom, which had 16 pairs of OSLDs and EBT3 films taped onto its surface at different anatomical positions. The doses recorded were read out to validate the absolute dosimetry for TSET. Results: The OSLD measurements were within 7% agreement with the planned dose except the shoulder areas, where the doses recorded were 23% lower on average than those of the planned. The EBT3 film measurements were within 10% agreement with the planned dose except the shoulder and the scalp vertex areas, where the respective doses recorded were 18% and 14% lower on average than those of the planned. The OSLDs gave more consistent dose measurements than those of the EBT3 films. Conclusion: The absolute dosimetry for TSET was validated by an end-to-end test with a Rando phantom using the OSLDs and EBT3 films. The beam calibration and monitor unit calculations were confirmed.

60 APPLIED LIFE SCIENCES↗

Estimation of the Risks of Collision or Strike to Freshwater Aquatic Organisms Resulting from Operation of Instream Hydrokinetic Turbines

Hydrokinetic energy technologies have been proposed as renewable, environmentally preferable alternatives to fossil fuels for generation of electricity. Hydrokinetic technologies harness the energy of water in motion, either from waves, tides or from river currents. For energy capture from free-flowing rivers, arrays of rotating devices are most commonly proposed. The placement of hydrokinetic devices in large rivers is expected to increase the underwater structural complexity of river landscapes. Moore and Gregory (1988) found that structural complexity increased local fish populations because fish and other aquatic biota are attracted to structural complexity that provides microhabitats with steep flow velocity gradients (Liao 2007). However, hydrokinetic devices have mechanical parts, blades, wings or bars that move through the water column, posing a potential strike or collision risk to fish and other aquatic biota. Furthermore, in a setting with arrays of hydrokinetic turbines the cumulative effects of multiple encounters may increase the risk of strike. Submerged structures associated with a hydrokinetic (HK) project present a collision risk to aquatic organisms and diving birds (Cada et al. 2007). Collision is physical contact between a device or its pressure field and an organism that may result in an injury to that organism (Wilson et al. 2007). Collisions can occur between animals and fixed submerged structures, mooring equipment, horizontal or vertical axis turbine rotors, and structures that, by their individual design or in combination, may form traps. This report defines strike as a special case of collision where a moving part, such as a rotor blade of a HK turbine intercepts the path of an organism of interest, resulting in physical contact with the organism. The severity of a strike incidence may range from minor physical contact with no adverse effects to the organism to severe strike resulting in injury or death of the organism. Harmful effects to animal populations could occur directly (e.g., from strike mortality of individuals) or indirectly (e.g., if the loss of prey species to strike reduces food for predators). Although actively swimming or passively drifting animals may collide with any of the physical structures associated with hydrokinetic devices, turbine rotors are the most likely sources for risk of strike or significant collision (DOE 2009). It is also possible that during a close encounter with a HK device no physical contact will be made between the device and the organism, either because the animal avoids the device by successfully changing its direction of movement, or by successfully evading any moving parts of the device. Oak Ridge National Laboratory (ORNL) has been funded by the US Department of Energy (DOE) Waterpower Program to evaluate strike potential and consequences for Marine and Hydrokinetic (MHK) technologies in rivers and estuaries of the United States. We will use both predictive models and laboratory/field experiments to evaluate the likelihood and consequences of strike at HK projects in rivers. Efforts undertaken at ORNL address three objectives: (1) Assess strike risk for marine and freshwater organisms; (2) Develop experimental procedures to assess the risk and consequences of strike; and (3) Conduct strike studies in experimental flumes and field installations of hydrokinetic devices. During the first year of the study ORNL collected information from the Federal Energy Regulatory Commission (FERC) MHK database about geographical distribution of proposed hydrokinetic projects (what rivers or other types of systems), HK turbine design (horizontal axis, vertical axis, other), description of proposed axial turbine (number of blades, size of blades, rotation rate, mitigation measures), and number of units per project. Where site specific information was available, we compared the location of proposed projects rotors within the channel (e.g., along cutting edge bank, middle of thalweg, near bottom or in midwater) to the general locations of fish in the river (shoreline, bottom/midwater/surface of channel) to ascertain potential interactions. In addition, we are collaborating and communicating with scientists at other national laboratories and industry who are also developing information useful to this task. For example, other studies being funded by DOE include evaluations of different in-current (hydrokinetic) turbine designs for their effects on rates and severity of blade strike and likelihood of cavitation. This report summarizes activities completed during the first year of a three-year study.

17 WIND ENERGY↗

Development of Geomechanical Screening Tools to Identify Risk: An Experimental and Modeling Approach for Secure CO 2 Storage Final Technical Report

CO 2 injection in the subsurface introduces additional complexity in terms of interactions of the reservoir host pore fluid with natural heterogeneity of hydro-mechanical properties of the rock. Natural heterogeneity of the reservoir rock and caprock formations includes spatial variation of hydro-mechanical properties as well as the presence of natural fractures. We developed a coupled mathematical modeling and experimental framework that takes into account the effect of rock heterogeneity on effective mechanical properties of the rock in contact with CO 2 . We performed accurate laboratory experiments to determine the changes in rock mechanical properties due to mineral dissolution in the presence of carbonic acid generated by CO 2 injection. A two-scale adaptive homogenization framework was then developed to consistently upscale petrophysical and geomechanical properties to the field scale. Further, we also developed high-fidelity, numerical solution schemes, non-linear and linear solvers and preconditioners to solve the coupled flow, reactive transport and geomechanical system. The numerical model was then used to study field scale CO 2 sequestration problems for the two selected field sites: (1) Frio formation and (2) Cranfield site. We also developed robust schemes for field data assimilation, model calibration such that the residual uncertainty at the end of the data assimilation procedures can be faithfully represented while taking into account the coupled geochemical and geomechanical processes.

42 ENGINEERING↗

Review of the November 11, 1905 Earthquake: Seismic Intensity Data, Magnitude, and Location Report

The macroseismic location and magnitude of the Shoshone 1905 earthquake has been based on the application of objective and quantitative approaches that produce estimates of earthquake source location and magnitude, and associated uncertainties. The performance of all three approaches applied depends critically on the characteristics of the seismic intensity field. Regional intensity attenuation relations were derived based on a calibration set of earthquakes and then, the procedure was validated using three independent very recent events. The macroseismic epicenter location was determined by either a grid search procedure, the spatial distribution of the sites experiencing the largest intensities, or a combination of both. The macroseismic magnitude estimates are based on the derived regional intensity attenuation relations. There is consistency in the location and magnitude of the November 1905 earthquake as obtained by the three methods. The overlapping region of the 68% bootstrap resampling solutions suggests a reliable epicenter location within 41.550N ? 42.060N and 113.478W ? 112.320W. This region encloses the original Oaks (1992) epicenter location. Macroseismic magnitude estimates range between 5.87 and 6.05.

58 GEOSCIENCES↗

Bayesian approach for three-dimensional aquifer characterization at the Hanford 300 Area

This study presents a stochastic, three-dimensional characterization of a heterogeneous hydraulic conductivity field within DOE's Hanford 300 Area site, Washington, by assimilating large-scale, constant-rate injection test data with small-scale, three-dimensional electromagnetic borehole flowmeter (EBF) measurement data. We first inverted the injection test data to estimate the transmissivity field, using zeroth-order temporal moments of pressure buildup curves. We applied a newly developed Bayesian geostatistical inversion framework, the method of anchored distributions (MAD), to obtain a joint posterior distribution of geostatistical parameters and local log-transmissivities at multiple locations. The unique aspects of MAD that make it suitable for this purpose are its ability to integrate multi-scale, multi-type data within a Bayesian framework and to compute a nonparametric posterior distribution. After we combined the distribution of transmissivities with depth-discrete relative-conductivity profile from EBF data, we inferred the three-dimensional geostatistical parameters of the log-conductivity field, using the Bayesian model-based geostatistics. Such consistent use of the Bayesian approach throughout the procedure enabled us to systematically incorporate data uncertainty into the final posterior distribution. The method was tested in a synthetic study and validated using the actual data that was not part of the estimation. Results showed broader and skewed posterior distributions of geostatistical parameters except for the mean, which suggests the importance of inferring the entire distribution to quantify the parameter uncertainty.

Murakami, Haruko↗