Search NASA⌕ Search

SEARCH · Search NASA

Results for “InSPIRE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

FDG-PET-Based Radiotherapy Planning in Lung Cancer: Optimum Breathing Protocol and Patient Positioning-An Intraindividual Comparison

Purpose: Fluoro-2-deoxy-D-glucose (FDG)-positron emission tomography (PET) and PET/computed tomography (CT) are increasingly used for radiotherapy (RT) planning in patients with non-small-cell lung carcinoma. The planning process often is based on separately acquired FDG-PET/CT and planning CT scans. We compared intraindividual differences between PET acquired in diagnostic (D-PET) and RT treatment position (RT-PET) coregistered with planning CTs acquired using different breathing protocols. Methods and Materials: Sixteen patients with non-small-cell lung carcinoma underwent two PET acquisitions (D-PET and RT-PET) and three planning CT acquisitions (expiration [EXP], inspiration [INS], and mid-breath hold [MID]) on the same day. All scans were rigidly coregistered, resulting in six fused data sets: D-INS, D-EXP, D-MID, RT-INS, RT-EXP, and RT-MID. Fusion accuracy was assessed by three readers at eight anatomic landmarks, lung apices, aortic arch, heart, spine, sternum, carina, diaphragm, and tumor, by using an alignment score ranging from 1 (no alignment) to 5 (exact alignment). Results: The RT-PET showed better alignment with any CT than D-PET (p < 0.001). With regard to breathing, RT-MID showed the best mean alignment score (3.7 {+-} 1.0), followed by RT-EXP (3.5 {+-} 0.9) and RT-INS (3.0 {+-} 0.8), with all differences significant (p < 0.001). Comparing alignment scores with regard to anatomic landmarks, the largest deviations were found at the diaphragm, heart, and apices. Overall, there was fair agreement ({kappa} = 0.48; p < 0.001) among the three readers. Conclusions: Significantly better fusion of PET and planning CT can be reached with PET acquired in the RT position. The best intraindividual fusion results are obtained with the planning CT performed during mid-breath hold. Our data justify the acquisition of a separate planning PET in RT treatment position if only a diagnostic PET scan is available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Utility of Four-Dimensional Computed Tomography for Analysis of Intrafractional and Interfractional Variation in Lung Volumes

Purpose: To assess the viability of four-dimensional (4D) computed tomography (CT) in describing intrafractional and interfractional changes in lung volumes and to determine which breathing phase, if any, produces the most highly reproducible lung volumes among fractions. Methods and Materials: Weekly 4D CT scans were acquired for 13 patients with non-small-cell lung cancer during a course of radiotherapy. Contours delineating the right lung, left lung, and total lung were obtained by adapting library models of the anatomic structures to the CT images and propagating them to all 10 respiratory phases represented in the 4D CT image data set. Lung volumes were calculated using software tools in a commercial radiation treatment-planning system and analyzed for interfractional volume reproducibility using t tests and for phase reproducibility using a phase-dependent uncertainty curve across all patients. Probability (p) values of <0.05 were considered to indicate significant differences in all comparisons. Results: The average mean coefficient of variation of tidal volume across all patients was 25.0%. The average standard deviation of tidal volumes was 5.7% relative to the lung volume at end-expiration. Total volumes measured at the 30% phase were 15% more consistent than those measured at end-inspiration (p = 0.03). Conclusions: Four-dimensional CT assesses lung volume with acceptable precision; but the technique was unable to accurately predict interfractional changes in lung volume because wide variations in intra- and interfractional breathing cause high uncertainties in 4D CT data acquisition. The most reproducible breathing phase seems to be at the 30-40% phase (just before end-expiration)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Multiple Breathing States Using a Multiple Instance Geometry Approximation (MIGA) in Inverse-Planned Optimization for Locoregional Breast Treatment

Purpose: Although previous work demonstrated superior dose distributions for left-sided breast cancer patients planned for intensity-modulated radiation therapy (IMRT) at deep inspiration breath hold compared with conventional techniques with free-breathing, such techniques are not always feasible to limit the impact of respiration on treatment delivery. This study assessed whether optimization based on multiple instance geometry approximation (MIGA) could derive an IMRT plan that is less sensitive to known respiratory motions. Methods and Materials: CT scans were acquired with an active breathing control device at multiple breath-hold states. Three inverse optimized plans were generated for eight left-sided breast cancer patients: one static IMRT plan optimized at end exhale, two (MIGA) plans based on a MIGA representation of normal breathing, and a MIGA representation of deep breathing, respectively. Breast and nodal targets were prescribed 52.2 Gy, and a simultaneous tumor bed boost was prescribed 60 Gy. Results: With normal breathing, doses to the targets, heart, and left anterior descending (LAD) artery were equivalent whether optimizing with MIGA or on a static data set. When simulating motion due to deep breathing, optimization with MIGA appears to yield superior tumor-bed coverage, decreased LAD mean dose, and maximum heart and LAD dose compared with optimization on a static representation. Conclusions: For left-sided breast-cancer patients, inverse-based optimization accounting for motion due to normal breathing may be similar to optimization on a static data set. However, some patients may benefit from accounting for deep breathing with MIGA with improvements in tumor-bed coverage and dose to critical structures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cumulative Lung Dose for Several Motion Management Strategies as a Function of Pretreatment Patient Parameters

Purpose: To evaluate patient parameters that may predict for relative differences in cumulative four-dimensional (4D) lung dose among several motion management strategies. Methods and Materials: Deformable image registration and dose accumulation were used to generate 4D treatment plans for 18 patients with 4D computed tomography scans. Three plans were generated to simulate breath hold at normal inspiration, target tracking with the beam aperture, and mid-ventilation aperture (control of the target at the mean daily position and application of an iteratively computed margin to compensate for respiration). The relative reduction in mean lung dose (MLD) between breath hold and mid-ventilation aperture ({delta}MLD{sub BH}) and between target tracking and mid-ventilation aperture ({delta}MLD{sub TT}) was calculated. Associations between these two variables and parameters of the lesion (excursion, size, location, and deformation) and dose distribution (local dose gradient near the target) were also calculated. Results: The largest absolute and percentage differences in MLD were 1.0 Gy and 21.5% between breath hold and mid-ventilation aperture. {delta}MLD{sub BH} was significantly associated (p < 0.05) with tumor excursion. The {delta}MLD{sub TT} was significantly associated with excursion, deformation, and local dose gradient. A linear model was constructed to represent {delta}MLD vs. excursion. For each 5 mm of excursion, target tracking reduced the MLD by 4% compared with the results of a mid-ventilation aperture plan. For breath hold, the reduction was 5% per 5 mm of excursion. Conclusions: The relative difference in MLD among different motion management strategies varied with patient and tumor characteristics for a given dosimetric target coverage. Tumor excursion is useful to aid in stratifying patients according to appropriate motion management strategies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An Evaluation of Two Internal Surrogates for Determining the Three-Dimensional Position of Peripheral Lung Tumors

Purpose: Both carina and diaphragm positions have been used as surrogates during respiratory-gated radiotherapy. We studied the correlation of both surrogates with three-dimensional (3D) tumor position. Methods and Materials: A total of 59 repeat artifact-free four-dimensional (4D) computed tomography (CT) scans, acquired during uncoached breathing, were identified in 23 patients with Stage I lung cancer. Repeat scans were co-registered to the initial 4D CT scan, and tumor, carina, and ipsilateral diaphragm were manually contoured in all phases of each 4D CT data set. Correlation between positions of carina and diaphragm with 3D tumor position was studied by use of log-likelihood ratio statistics. Models to predict 3D tumor position from internal surrogates at end inspiration (EI) and end expiration (EE) were developed, and model accuracy was tested by calculating SDs of differences between predicted and actual tumor positions. Results: Motion of both the carina and diaphragm significantly correlated with tumor motion, but log-likelihood ratios indicated that the carina was more predictive for tumor position. When craniocaudal tumor position was predicted by use of craniocaudal carina positions, the SDs of the differences between the predicted and observed positions were 2.2 mm and 2.4 mm at EI and EE, respectively. The corresponding SDs derived with the diaphragm positions were 3.7 mm and 3.9 mm at EI and EE, respectively. Prediction errors in the other directions were comparable. Prediction accuracy was similar at EI and EE. Conclusions: The carina is a better surrogate of 3D tumor position than diaphragm position. Because residual prediction errors were observed in this analysis, additional studies will be performed using audio-coached scans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Unacceptable Cosmesis in a Protocol Investigating Intensity-Modulated Radiotherapy With Active Breathing Control for Accelerated Partial-Breast Irradiation

Purpose: To report interim cosmetic results and toxicity from a prospective study evaluating accelerated partial-breast irradiation (APBI) administered using a highly conformal external beam approach. Methods and Materials: We enrolled breast cancer patients in an institutional review board-approved prospective study of APBI using beamlet intensity-modulated radiotherapy (IMRT) at deep-inspiration breath-hold. Patients received 38.5 Gy in 3.85 Gy fractions twice daily. Dosimetric parameters in patients who maintained acceptable cosmesis were compared with those in patients developing unacceptable cosmesis in follow-up, using t-tests. Results: Thirty-four patients were enrolled; 2 were excluded from analysis because of fair baseline cosmesis. With a median follow-up of 2.5 years, new unacceptable cosmesis developed in 7 patients, leading to early study closure. We compared patients with new unacceptable cosmesis with those with consistently acceptable cosmesis. Retrospective analysis demonstrated that all but one plan adhered to the dosimetric requirements of the national APBI trial. The mean proportion of a whole-breast reference volume receiving 19.25 Gy (V50) was lower in patients with acceptable cosmesis than in those with unacceptable cosmesis (34.6% vs. 46.1%; p = 0.02). The mean percentage of this reference volume receiving 38.5 Gy (V100) was also lower in patients with acceptable cosmesis (15.5% vs. 23.0%; p = 0.02). Conclusions: The hypofractionated schedule and parameters commonly used for external beam APBI and prescribed by the ongoing national trial may be suboptimal, at least when highly conformal techniques such as IMRT with management of breathing motion are used. The V50 and V100 of the breast reference volume seem correlated with cosmetic outcome, and stricter limits may be appropriate in this setting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Accelerated Partial Breast Irradiation: What is Dosimetric Effect of Advanced Technology Approaches?

Purpose: The present treatment planning study compared whole breast radiotherapy (WBRT) to accelerated partial breast irradiation (APBI) for different external beam techniques and geometries (e.g., free breathing [FB] and deep inspiration breath hold [DIBH]). Methods and Materials: After approval by our institutional review board, a treatment planning study was performed of 10 patients with left-sided Stage 0-I breast cancer enrolled in a Phase I-II study of APBI using intensity-modulated radiotherapy (IMRT). After lumpectomy, patients underwent planning computed tomography scans during FB and using an active breathing control device at DIBH. For the FB geometry, standard WBRT and three-dimensional conformal radiotherapy (3D-CRT) APBI plans were created. For the DIBH geometry with active breathing control, WBRT, 3D-CRT, and IMRT APBI plans were created. Results: All APBI techniques had excellent planning target volume coverage. The maximal planning target volume dose was reduced from 116% of the prescription dose to 108% with the IMRT(DIBH) APBI plan. The maximal heart dose was >30 Gy for the WBRT techniques, 8.2 Gy for 3D-CRT(FB), and <5.0 Gy for 3D-CRT(DIBH) and IMRT(DIBH) techniques. The mean left anterior descending artery dose was significantly reduced from 11.4 Gy with WBRT(FB) to 4.2 with WBRT(DIBH) and <2.0 Gy with all APBI techniques. Conclusion: Although planning target volume coverage was acceptable with all techniques, the plans using the DIBH geometry resulted in a marked reduction in the normal tissue dose compared with WBRT planned in the absence of cardiac blocking. Additional study is needed to determine whether these techniques result in clinical benefits.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lack of Correlation Between External Fiducial Positions and Internal Tumor Positions During Breath-Hold CT

Purpose: For thoracic tumors, if four-dimensional computed tomography (4DCT) is unavailable, the internal margin can be estimated by use of breath-hold (BH) CT scans acquired at end inspiration (EI) and end expiration (EE). By use of external surrogates for tumor position, BH accuracy is estimated by minimizing the difference between respiratory extrema BH and mean equivalent-phase free breathing (FB) positions. We tested the assumption that an external surrogate for BH accuracy correlates with internal tumor positional accuracy during BH CT. Methods and Materials: In 16 lung cancer patients, 4DCT images, as well as BH CT images at EI and EE, were acquired. Absolute differences between BH and mean equivalent-phase (FB) positions were calculated for both external fiducials and gross tumor volume (GTV) centroids as metrics of external and internal BH accuracy, respectively, and the results were correlated. Results: At EI, the absolute difference between mean FB and BH fiducial displacement correlated poorly with the absolute difference between FB and BH GTV centroid positions on CT images (R{sup 2} = 0.11). Similarly, at EE, the absolute difference between mean FB and BH fiducial displacements correlated poorly with the absolute difference between FB and BH GTV centroid positions on CT images (R{sup 2} = 0.18). Conclusions: External surrogates for tumor position are not an accurate metric of BH accuracy for lung cancer patients. This implies that care should be taken when using such an approach because an incorrect internal margin could be generated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anatomic and Pathologic Variability During Radiotherapy for a Hybrid Active Breath-Hold Gating Technique

Purpose: To evaluate intra- and interfraction variability of tumor and lung volume and position using a hybrid active breath-hold gating technique. Methods and Materials: A total of 159 repeat normal inspiration active breath-hold CTs were acquired weekly during radiotherapy for 9 lung cancer patients (12-21 scans per patient). A physician delineated the gross tumor volume (GTV), lungs, and spinal cord on the first breath-hold CT, and contours were propagated semiautomatically. Intra- and interfraction variability of tumor and lung position and volume were evaluated. Tumor centroid and border variability were quantified. Results: On average, intrafraction variability of lung and GTV centroid position was <2.0 mm. Interfraction population variability was 3.6-6.7 mm (systematic) and 3.1-3.9 mm (random) for the GTV centroid and 1.0-3.3 mm (systematic) and 1.5-2.6 mm (random) for the lungs. Tumor volume regressed 44.6% {+-} 23.2%. Gross tumor volume border variability was patient specific and demonstrated anisotropic shape change in some subjects. Interfraction GTV positional variability was associated with tumor volume regression and contralateral lung volume (p < 0.05). Inter-breath-hold reproducibility was unaffected by time point in the treatment course (p > 0.1). Increases in free-breathing tidal volume were associated with increases in breath-hold ipsilateral lung volume (p < 0.05). Conclusions: The breath-hold technique was reproducible within 2 mm during each fraction. Interfraction variability of GTV position and shape was substantial because of tumor volume and breath-hold lung volume change during therapy. These results support the feasibility of a hybrid breath-hold gating technique and suggest that online image guidance would be beneficial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Respiratory Organ Motion and Dosimetric Impact on Breast and Nodal Irradiation

Purpose: To examine the respiratory motion for target and normal structures during whole breast and nodal irradiation and the resulting dosimetric impact. Methods and Materials: Four-dimensional CT data sets of 18 patients with early-stage breast cancer were analyzed retrospectively. A three-dimensional conformal dosimetric plan designed to irradiate the breast was generated on the basis of CT images at 20% respiratory phase (reference phase). The reference plans were copied to other respiratory phases at 0% (end of inspiration) and 50% (end of expiration) to simulate the effects of breathing motion on whole breast irradiation. Dose-volume histograms, equivalent uniform dose, and normal tissue complication probability were evaluated and compared. Results: Organ motion of up to 8.8 mm was observed during free breathing. A large lung centroid movement was typically associated with a large shift of other organs. The variation of planning target volume coverage during a free breathing cycle is generally within 1%-5% (17 of 18 patients) compared with the reference plan. However, up to 28% of V{sub 45} variation for the internal mammary nodes was observed. Interphase mean dose variations of 2.2%, 1.2%, and 1.4% were observed for planning target volume, ipsilateral lung, and heart, respectively. Dose variations for the axillary nodes and brachial plexus were minimal. Conclusions: The doses delivered to the target and normal structures are different from the planned dose based on the reference phase. During normal breathing, the dosimetric impact of respiratory motion is clinically insignificant with the exception of internal mammary nodes. However, noticeable degradation in dosimetric plan quality may be expected for the patients with large respiratory motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interfractional Reproducibility of Lung Tumor Location Using Various Methods of Respiratory Motion Mitigation

Purpose: To determine interfractional reproducibility of the location of lung tumors using respiratory motion mitigation. Methods and Materials: Free-breathing four-dimensional computed tomography (CT) data sets and CT data sets during breath hold were acquired weekly for 17 patients undergoing treatment for non-small-cell lung cancer. Distances between the center of the gross tumor volume (GTV) and a reproducible bony reference point under conditions of breath hold on end inspiration (EI) and end expiration (EE) and during free breathing on the 0% phase (corresponding to EI) and 50% phase (corresponding to EE) were analyzed for interfractional reproducibility. Systematic uncertainties in tumor location were determined as the difference in distance between the GTV center on the first CT data set and the mean location of GTV centers on the subsequent data sets. Random uncertainties in tumor location were determined as the standard deviation of the distances between the GTV centers and the bony reference points. Margins to account for systematic and random interfractional variations were estimated based on these uncertainties. Results: Mean values of interfractional setup uncertainties were as follows: systematic uncertainties-EI, 0.3 cm; EE, 0.2 cm; 0% phase, 0.3 cm; and 50% phase, 0.3 cm; and random uncertainties-EI, 0.3 cm; EE, 0.3 cm; 0% phase, 0.3 cm; and 50% phase, 0.3 cm. There does not appear to be any correlation between uncertainties and GTV size, but there appears to be a weak positive correlation between uncertainties and the magnitude of GTV excursion. Conclusions: Voluntary breath hold and gating on either EI or EE appear to be equally reliable methods of ensuring the reproducibility of lung tumor position. We recommend setup margins of 0.3 cm if using cone-beam CT or kilovoltage X-ray with fiducials and aligning directly to the tumor and 0.8 cm when aligning to a nearby bony surrogate using cone-beam CT or kilovoltage X-ray.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Four Techniques Using Intensity-Modulated Radiation Therapy for Comprehensive Locoregional Irradiation of Breast Cancer

Purpose: To establish optimal intensity-modulated radiation therapy (IMRT) techniques for treating the left breast and regional nodes, using moderate deep-inspiration breath hold. Methods and Materials: We developed four IMRT plans of differing complexity for each of 10 patients following lumpectomy for left breast cancer. A dose of 60 Gy was prescribed to the boost planning target volume (PTV) and 52.2 Gy to the breast and supraclavicular, infraclavicular, and internal mammary nodes. Two plans used inverse-planned beamlet techniques: a 9-field technique, with nine equispaced axial beams, and a tangential beamlet technique, with three to five ipsilateral beams. The third plan (a segmental technique) used a forward-planned multisegment technique, and the fourth plan (a segmental blocked technique) was identical but included a block to limit heart dose. Dose--volume histograms were generated, and metrics chosen for comparison were analyzed using the paired t test. Results: Mean heart and left anterior descending coronary artery doses were similar with the tangential beamlet and segmental blocked techniques but higher with the segmental and 9-field techniques (mean paired difference of 15.1 Gy between segmental and tangential beamlet techniques, p < 0.001). Substantial volumes of contralateral tissue received dose with the 9-field technique (mean right breast V2, 58.9%; mean right lung V2, 75.3%). Minimum dose to {>=}95% of breast PTV was, on average, 45.9 Gy with tangential beamlet, 45.0 Gy with segmental blocked, 51.4 Gy with segmental, and 50.2 Gy with 9-field techniques. Coverage of the internal mammary region was substantially better with the two beamlet techniques than with the segmental blocked technique. Conclusions: Compared to the 9-field beamlet and segmental techniques, a tangential beamlet IMRT technique reduced exposure to normal tissues and maintained reasonable target coverage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Implementation of Feedback-Guided Voluntary Breath-Hold Gating for Cone Beam CT-Based Stereotactic Body Radiotherapy

Purpose: To analyze tumor position reproducibility of feedback-guided voluntary deep inspiration breath-hold (FGBH) gating for cone beam computed tomography (CBCT)-based stereotactic body radiotherapy (SBRT). Methods and materials: Thirteen early-stage lung cancer patients eligible for SBRT with tumor motion of >1cm were evaluated for FGBH-gated treatment. Multiple FGBH CTs were acquired at simulation, and single FGBH CBCTs were also acquired prior to each treatment. Simulation CTs and treatment CBCTs were analyzed to quantify reproducibility of tumor positions during FGBH. Benefits of FGBH gating compared to treatment during free breathing, as well treatment with gating at exhalation, were examined for lung sparing, motion margins, and reproducibility of gross tumor volume (GTV) position relative to nonmoving anatomy. Results: FGBH increased total lung volumes by 1.5 times compared to free breathing, resulting in a proportional drop in total lung volume receiving 10 Gy or more. Intra- and inter-FGBH reproducibility of GTV centroid positions at simulation were 1.0 {+-} 0.5 mm, 1.3 {+-} 1.0 mm, and 0.6 {+-} 0.4 mm in the anterior-posterior (AP), superior-inferior (SI), and left-right lateral (LR) directions, respectively, compared to more than 1 cm of tumor motion at free breathing. During treatment, inter-FGBH reproducibility of the GTV centroid with respect to bony anatomy was 1.2 {+-} 0.7 mm, 1.5 {+-} 0.8 mm, and 1.0 {+-} 0.4 mm in the AP, SI, and LR directions. In addition, the quality of CBCTs was improved due to elimination of motion artifacts, making this technique attractive for poorly visualized tumors, even with small motion. Conclusions: The extent of tumor motion at normal respiration does not influence the reproducibility of the tumor position under breath hold conditions. FGBH-gated SBRT with CBCT can improve the reproducibility of GTV centroids, reduce required margins, and minimize dose to normal tissues in the treatment of mobile tumors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality Assurance of 4D-CT Scan Techniques in Multicenter Phase III Trial of Surgery Versus Stereotactic Radiotherapy (Radiosurgery or Surgery for Operable Early Stage (Stage 1A) Non-Small-Cell Lung Cancer [ROSEL] Study)

Purpose: To determine the accuracy of four-dimensional computed tomography (4D-CT) scanning techniques in institutions participating in a Phase III trial of surgery vs. stereotactic radiotherapy (SBRT) for lung cancer. Methods and Materials: All 9 centers performed a 4D-CT scan of a motion phantom (Quasar, Modus Medical Devices) in accordance with their in-house imaging protocol for SBRT. A cylindrical cedar wood insert with plastic spheres of 15 mm (o15) and 30 mm (o30) diameter was moved in a cosine-based pattern, with an extended period in the exhale position to mimic the actual breathing motion. A range of motion of R = 15 and R = 25 mm and breathing period of T = 3 and T = 6 s were used. Positional and volumetric imaging accuracy was analyzed using Pinnacle version 8.1x at various breathing phases, including the mid-ventilation phase and maximal intensity projections of the spheres. Results: Imaging using eight CT scanners (Philips, Siemens, GE) and one positron emission tomography-CT scanner (Institution 3, Siemens) was investigated. The imaging protocols varied widely among the institutions. No strong correlation was found between the specific scan protocol parameters and the observed results. Deviations in the maximal intensity projection volumes averaged 1.9% (starting phase of the breathing cycle [o]15, R = 15), 12.3% (o15, R = 25), and -0.9% (o30, R = 15). The end-expiration volume deviations (13.4%, o15 and 2.5%, o30), were, on average, smaller than the end-inspiration deviations (20.7%, o15 and 4.5%, o30), which, in turn, were smaller than the mid-ventilation deviations (32.6%, o15 and 8.0%, o30). A slightly larger variation in the mid-ventilation origin position was observed (mean, -0.2 mm; range, -3.6-4.2) than in the maximal intensity projection origin position (mean, -0.1 mm; range, -2.5-2.5). The range of motion was generally underestimated (mean, -1.5 mm; range, -5.5-1). Conclusions: Notable differences were seen in the 4D-CT imaging protocols for SBRT among centers. However, the observed deviations in target volumes were generally small. They were slightly larger for the mid-ventilation phases and smallest for the end-expiration phases. Steps to optimize and standardize the 4D-CT scanning protocols for SBRT are desirable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Involved-Node Radiotherapy and Modern Radiation Treatment Techniques in Patients With Hodgkin Lymphoma

Purpose: To assess the clinical outcome of the involved-node radiotherapy (INRT) concept using modern radiation treatments (intensity-modulated radiotherapy [IMRT]or deep-inspiration breath-hold radiotherapy [DIBH) in patients with localized supradiaphragmatic Hodgkin lymphoma. Methods and Materials: All but 2 patients had early-stage Hodgkin lymphoma, and they were treated with chemotherapy prior to irradiation. Radiation treatments were delivered using the INRT concept according to European Organization for Research and Treatment of Cancer guidelines. IMRT was performed with the patient free-breathing. For the adapted breath-hold technique, a spirometer dedicated to DIBH radiotherapy was used. Three-dimensional conformal radiotherapy was performed with those patients. Results: Fifty patients with Hodgkin lymphoma (48 patients with primary Hodgkin lymphoma, 1 patient with recurrent disease, and 1 patient with refractory disease) entered the study from January 2003 to August 2008. Thirty-two patients were treated with IMRT, and 18 patients were treated with the DIBH technique. The median age was 28 years (range, 17-62 years). Thirty-four (68%) patients had stage I - (I-IIA) IIA disease, and 16 (32%) patients had stage I - (I-IIB) IIB disease. All but 3 patients received three to six cycles of adriamycin, bleomycin, vinblastine, and dacarbazine (ABVD). The median radiation doses to patients treated with IMRT and DIBH were, respectively, 40 Gy (range, 21.6-40 Gy) and 30.6 Gy (range, 19.8-40 Gy). Protection of various organs at risk was satisfactory. Median follow-up was 53.4 months (range, 19.1-93 months). The 5-year progression-free and overall survival rates for the whole population were 92% (95% confidence interval [CI], 80%-97%) and 94% (95% CI, 75%-98%), respectively. Recurrences occurred in 4 patients: 2 patients had in-field relapses, and 2 patients had visceral recurrences. Grade 3 acute lung toxicity (transient pneumonitis) occurred in 1 case. Conclusions: Our results suggest that patients with localized Hodgkin lymphoma can be safely and efficiently treated using the INRT concept and modern radiation treatment techniques such as IMRT and DIBH.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Rapid Automated Treatment Planning Process to Select Breast Cancer Patients for Active Breathing Control to Achieve Cardiac Dose Reduction

Purpose: To evaluate a rapid automated treatment planning process for the selection of patients with left-sided breast cancer for a moderate deep inspiration breath-hold (mDIBH) technique using active breathing control (ABC); and to determine the dose reduction to the left anterior descending coronary artery (LAD) and the heart using mDIBH. Method and Materials: Treatment plans were generated using an automated method for patients undergoing left-sided breast radiotherapy (n = 53) with two-field tangential intensity-modulated radiotherapy. All patients with unfavorable cardiac anatomy, defined as having >10 cm{sup 3} of the heart receiving 50% of the prescribed dose (V{sub 50}) on the free-breathing automated treatment plan, underwent repeat scanning on a protocol using a mDIBH technique and ABC. The doses to the LAD and heart were compared between the free-breathing and mDIBH plans. Results: The automated planning process required approximately 9 min to generate a breast intensity-modulated radiotherapy plan. Using the dose-volume criteria, 20 of the 53 patients were selected for ABC. Significant differences were found between the free-breathing and mDIBH plans for the heart V{sub 50} (29.9 vs. 3.7 cm{sup 3}), mean heart dose (317 vs. 132 cGy), mean LAD dose (2,047 vs. 594 cGy), and maximal dose to 0.2 cm{sup 3} of the LAD (4,155 vs. 1,507 cGy, all p <.001). Of the 17 patients who had a breath-hold threshold of {>=}0.8 L, 14 achieved a {>=}90% reduction in the heart V{sub 50} using the mDIBH technique. The 3 patients who had had a breath-hold threshold <0.8 L achieved a lower, but still significant, reduction in the heart V{sub 50}. Conclusions: A rapid automated treatment planning process can be used to select patients who will benefit most from mDIBH. For selected patients with unfavorable cardiac anatomy, the mDIBH technique using ABC can significantly reduce the dose to the LAD and heart, potentially reducing the cardiac risks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Artifacts in Conventional Computed Tomography (CT) and Free Breathing Four-Dimensional CT Induce Uncertainty in Gross Tumor Volume Determination

Purpose: Artifacts impacting the imaged tumor volume can be seen in conventional three-dimensional CT (3DCT) scans for planning of lung cancer radiotherapy but can be reduced with the use of respiration-correlated imaging, i.e., 4DCT or breathhold CT (BHCT) scans. The aim of this study was to compare delineated gross tumor volume (GTV) sizes in 3DCT, 4DCT, and BHCT scans of patients with lung tumors. Methods and Materials: A total of 36 patients with 46 tumors referred for stereotactic radiotherapy of lung tumors were included. All patients underwent positron emission tomography (PET)/CT, 4DCT, and BHCT scans. GTVs in all CT scans of individual patients were delineated during one session by a single physician to minimize systematic delineation uncertainty. The GTV size from the BHCT was considered the closest to true tumor volume and was chosen as the reference. The reference GTV size was compared to GTV sizes in 3DCT, at midventilation (MidV), at end-inspiration (Insp), and at end-expiration (Exp) bins from the 4DCT scan. Results: The median BHCT GTV size was 4.9 cm{sup 3} (0.1-53.3 cm{sup 3}). Median deviation between 3DCT and BHCT GTV size was 0.3 cm{sup 3} (-3.3 to 30.0 cm{sup 3}), between MidV and BHCT size was 0.2 cm{sup 3} (-5.7 to 19.7 cm{sup 3}), between Insp and BHCT size was 0.3 cm{sup 3} (-4.7 to 24.8 cm{sup 3}), and between Exp and BHCT size was 0.3 cm{sup 3} (-4.8 to 25.5 cm{sup 3}). The 3DCT, MidV, Insp, and Exp median GTV sizes were all significantly larger than the BHCT median GTV size. Conclusions: In the present study, the choice of CT method significantly influenced the delineated GTV size, on average, leading to an increase in GTV size compared to the reference BHCT. The uncertainty caused by artifacts is estimated to be in the same magnitude as delineation uncertainty and should be considered in the design of margins for radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantification of Contralateral Breast Dose and Risk Estimate of Radiation-Induced Contralateral Breast Cancer Among Young Women Using Tangential Fields and Different Modes of Breathing

Purpose: Whole breast irradiation with deep-inspiration breath-hold (DIBH) technique among left-sided breast cancer patients significantly reduces cardiac irradiation; however, a potential disadvantage is increased incidental irradiation of the contralateral breast. Methods and Materials: Contralateral breast dose (CBD) was calculated by comparing 400 treatment plans of 200 left-sided breast cancer patients whose tangential fields had been planned on gated and nongated CT data sets. Various anatomic and field parameters were analyzed for their impact on CBD. For a subgroup of patients (aged {<=}45 years) second cancer risk in the contralateral breast (CB) was modeled by applying the linear quadratic model, compound models, and compound models considering dose-volume information (DVH). Results: The mean CBD was significantly higher in DIBH with 0.69 Gy compared with 0.65 Gy in normal breathing (P=.01). The greatest impact on CBD was due to a shift of the inner field margin toward the CB in DIBH (mean 0.4 cm; range, 0-2), followed by field size in magnitude. Calculation with different risk models for CBC revealed values of excess relative risk/Gy ranging from 0.48-0.65 vs 0.46-0.61 for DIBH vs normal breathing, respectively. Conclusion: Contralateral breast dose, although within a low dose range, was mildly but significantly increased in 200 treatment plans generated under gated conditions, predominately due to a shift in the medial field margin. Risk modeling for CBC among women aged {<=}45 years also pointed to a higher risk when comparing DIBH with normal breathing. This risk, however, was substantially lower in the model considering DVH information. We think that clinical decisions should not be affected by this small increase in CBD with DIBH because DIBH is effective in reducing the dose to the heart in all patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗