Search NASA⌕ Search

SEARCH · Search NASA

Results for “Injection testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Degradable Biocomposite Thermoplastic Polyurethanes

In this project, the team developed tough and degradable biocomposite thermoplastic polyurethanes (TPUs) by incorporating bacterial spores into TPUs as a biofunctional living filler. The team screened various bacteria and selected the Bacillus subtilis ATCC 6633 strain as the final candidate, primarily due to its genomic availability, sporulation ability and TPU assimilation activity. The heat-shock tolerance of ATCC 6633 spores was further improved through evolutionary engineering via Adaptive Laboratory Evolution (ALE), demonstrating a 17.7-fold enhanced germination efficiency post heat-shock treatment compared to the wild-type strain (WT). The team fabricated biocomposite TPUs by incorporating lyophilized powder of heat-shock tolerized (HST) spores during the hot melt extrusion (HME) of TPU at 135 °C. The baseline TPU used in this project is a commercially available soft-grade TPU (BCF45) manufactured by BASF. Colony forming unit (CFU) assays quantified that WT and HST spores in the TPU matrix retained approximately 20% and 100% survivability, respectively, after HME. Tensile testing demonstrated that the spores behaved as a polymer-reinforcing filler, positively affecting the overall tensile properties of the biocomposite TPU. For example, biocomposite TPU with WT and HST spores (BC TPU WT and BC TPU HST , respectively) exhibited up to 25% and 37% improved toughness, respectively, compared to TPU without spores. BC TPU HST showed remarkably improved disintegration in autoclaved compost (92% mass loss in 5 months), which simulated a microbially poor environment for TPU degradation. When compared to TPU without spores (44% mass loss in 5 months) the acceleration of degradation is marked. Respirometry confirmed that 72% of BC TPU HST was biomineralized into CO2 within 6 months, indicating that spores in the biocomposite TPU were germinated by utilizing nutrients in the autoclaved compost, facilitating TPU degradation at the end of the material's life. The team demonstrated the scale-up of biocomposite TPU fabrication using continuous extrusion and injection molding techniques. Processing conditions optimized in a lab-scale microcompounder were successfully transferred to a continuous extruder with a 30-fold increased throughput. Biocomposite TPUs prepared using these industry-relevant processes showed comparable toughness improvements to samples prepared in the lab-scale extruder. Excitingly, following compounding in the pilot-extruder the composite material could be injection molded, while retaining high spore viability and similar toughness improvements. The team also found that spores in biocomposite TPU served as antioxidants, preventing toughness decay during the recycled extrusion of BC TPU HST . Long-term storage tests over one year showed that the addition of spores had no negative effect on the longevity of the TPU. Furthermore, the team demonstrated the fabrication of spore-bearing biocomposite polymers with other polyesters such as PBAT, PLA, and PCL. We obtained promising preliminary data that showed overall toughness improvements for all polymers with spore addition. Finally, life cycle assessment (LCA) and techno-economic analysis (TEA) were carried out, which indicated minimal additional cost of fabrication. Overall, a tough and degradable biocomposite thermoplastic was successfully developed through this project, with all tasks completed successfully, achieving >100% of the objectives.

36 MATERIALS SCIENCE↗

Nonmetallic Material Compatibility with Liquid Fluorine

Static tests were made on the compatibility of liquid fluorine with several nonmetallic materials at -3200 F and at pressures of 0 and 1500 pounds per square inch gage. The results are compared with those from previous work with gaseous fluorine at the same pressures, but at atmospheric temperature. In general, although environmental effects were not always consistent, reactivity was least with the low-temperature, low-pressure liquid fluorine. Reactivity was greatest with the warm, high-pressure gaseous fluorine. None of the liquids and greases tested was found to be entirely suitable for use in fluorine systems. Polytrifluorochloroethylene and N-43, the formula for which is (C4F9)3N, did not react with liquid fluorine at atmospheric pressure or 1500 pounds per square inch gage under static conditions, but they did react when injected into liquid fluorine at 1500 pounds per square inch gage; they also reacted with gaseous fluorine at 1500 pounds per square inch gage. While water did not react with liquid fluorine at 1500 pounds per square inch gage, it is known to react violently with fluorine under other conditions. The pipe-thread lubricant Q-Seal did not react with liquid fluorine, but did react with gaseous fluorine at 1500 pounds per square inch gage. Of the solids, ruby (Al2O3) and Teflon did not react under the test conditions. The results show that the compatibility of fluorine with nonmetals depends on the state of the fluorine and the system design.

Price, Harold G , Jr↗

The charge injection device /CID/ as a stellar tracking sensor

A 128 x 128 element CID imager was operated in a simulated stellar trackling environment and evaluated for temporal and pattern noise and spectral response over a temperature range of -40 C to +25 C. The test devices were fabricated on long-lifetime bulk silicon material and utilized very thin upper-level polysilicon electrodes for enhanced spectral response. A standard microcomputer was used to generate all control signals and to collect and process performance data. The results of this program were used to predict the performance of a 400 x 400 CID array designed specifically for stellar-tracking.

Burke, H. K.↗

Quantitative non-destructive testing

The work undertaken during this period included two primary efforts. The first is a continuation of theoretical development from the previous year of models and data analyses for NDE using the Optical Thermal Infra-Red Measurement System (OPTITHIRMS) system, which involves heat injection with a laser and observation of the resulting thermal pattern with an infrared imaging system. The second is an investigation into the use of the thermoelastic effect as an effective tool for NDE. As in the past, the effort is aimed towards NDE techniques applicable to composite materials in structural applications. The theoretical development described produced several models of temperature patterns over several geometries and material types. Agreement between model data and temperature observations was obtained. A model study with one of these models investigated some fundamental difficulties with the proposed method (the primitive equation method) for obtaining diffusivity values in plates of thickness and supplied guidelines for avoiding these difficulties. A wide range of computing speeds was found among the various models, with a one-dimensional model based on Laplace's integral solution being both very fast and very accurate.

Welch, C. S.↗

Improved Cryostat for Cooling a Wide Panel

An improved cryostat has been developed for cooling a wide panel evenly over its surface to a temperature of -423 F (approximately equal to -253 C) by use of liquid helium. Originally, the cryostat was to be used in measuring apparent strains in wide aluminum/lithium panels as functions of temperature in order to develop data for temperature compensation of the readings of strain gauges on a tank containing liquid hydrogen. Relative to the cryostat used previously for this purpose, the improved cryostat can be prepared for a test in less time, and it loses less helium during each test. Each wide panel to be tested is instrumented with thermocouples in preparation for a test. The previous cryostat was made of two aluminum halves that, for each test, were sandwiched together and sealed around the instrumented wide panel to be tested. The panel was thus enclosed in a plenum. The cryostat and adjacent panel areas protruding from the cryostat were then coated with a thermally insulating foam. During a test, liquid helium was made to flow into the plenum through a port on the bottom. The helium vaporized and expanded, filling the plenum with cold helium gas, which eventually flowed out of the plenum through a port on the top. The nature of the flow was such that a significant portion of the helium did not come into contact with the wide panel; hence, cooling was less efficient than it might otherwise have been. After completion of each test, the foam and the cryostat were separated from the panel. The cryostat was cleaned and prepared for installation on another instrumented wide panel for the next test. It took 28 hours to install the cryostat onto the instrumented panel, apply the foam, and perform ancillary operations in preparation for a test. The volume of liquid helium consumed during each test was 750 liters. The improved cryostat (see figure) includes an upper section and a lower section, both of which include permanent housings made of a thermally insulating foam 2-in. (approximately equal to 5-cm) thick. A liquid-helium- injection manifold is attached to the inside of the top section. The bottom section includes an outlet for helium gas. The manifold contains slots that, when the cryostat is installed on the panel, are located approximately 1 in. (approximately equal to 2.5 cm) from the wide panel. The array of slots spans a substantial portion of the area of the panel. The top and bottom sections of the cryostat are sealed to the panel by use of polytetrafluoroethylene cord and aluminum tape. Liquid helium is fed into the manifold from the top. The helium leaves the manifold through the slots and thus impinges directly on the panel. Hence, all the helium entering the cryostat must come into contact with the panel before leaving the cryostat. After a test, the cryostat is removed from the panel and reinstalled onto another panel for the next test. Installation of the cryostat on an instrumented panel takes a negligible amount of time, in comparison with the 28 hours associated with the previous cryostat. The amount of liquid helium consumed during a test in the improved cryostat is 500 liters - 250 liters less than before.

Clifton, W. B.↗

Manufacturing of Continuous Core–Shell Hydrated Salt Fibers for Room Temperature Thermal Energy Storage

The encapsulation of salt hydrate phase change materials (PCMs) in uniform microscale bodies has yet been reported in research due in part to the delicate relationship between thermal performance and water-to-salt ratios which are easily altered during manufacturing. Herein, core–shell composite fibers comprised of a salt hydrate PCM core and a poly(acrylonitrile) (PAN) shell are wet spun in a continuous process using a syringe pump and coaxial die. The PCM phase comprises calcium chloride hexahydrate (CaCl 2 ·6H 2 O) with strontium chloride hexahydrate(SrCl 2 ·6H 2 O) (3 wt%) and fumed silica(SiO 2 ) (2 wt%) as additive, a composition that is prepared from homogenous melt at 40 °C. 15 wt% PAN in dimethylsulfoxide solvent is used to prepare the shell-forming polymer gel. PCM and polymer gel injection rates of 10–40 mL h –1 are used to spin coaxial fibers through a coagulation bath, yielding continuous microtubules with diameters in the range of 850–1500 μm. Cyclic testing shows that after 1000 cycles, melting enthalpies incurred only a 3.5% decline from 131.46 to 126.9 J g –1 . In conclusion, success here overcomes several coincidental drawbacks of PCM fiber performance and manufacturing and delivers the first example of scalable roll-to-roll PCM fiber produced by wet spinning for building material applications.

36 MATERIALS SCIENCE↗

Calibrated dilatometer exercise to probe thermoplastic properties of coal in pressurized CO 2

This research was aimed at testing a hypothesis, that at elevated CO 2 pressure coal can soften at temperatures well below those obtained in the presence of other gases. That could have serious negative implications for injection of CO 2 into deep coal seams. Here, we have examined the experimental design issues and procedures used in the previously published studies, and experimentally investigated the physical behavior of a similar coal in the presence of CO 2 as a function of pressure and temperature, using the same high-pressure micro-dilatometer refurbished and carefully calibrated for this purpose. No notable reduction in coal softening temperature was observed in this study.

01 COAL, LIGNITE, AND PEAT↗

A thermally-limited bubble growth model for the relaxation time of superheated fuels

Here, we propose a novel approach to evaluate the relaxation time of vapor bubble growth in the context of the flash boiling of a superheated liquid. In alternative to the empirical correlation derived from superheated water experiments almost fifty years ago, the new model describes the thermally-dominated growth of vapor bubbles in terms that are dependent on the local Jakob number (the ratio of sensible heat to latent heat during phase change) and the number density of vapor bubbles. The model is tested by plugging the resulting relaxation time into the Homogenous Relaxation Model (HRM). Flash-boiling simulations carried out with HRM are compared with n-pentane (C 5 H 12 ) injection and boil-off experiments conducted with a real-size, axial-hole, transparent gasoline injector discharging into a constant-pressure vessel. The long-distance microscopy images from the experiments, processed to derive the projected liquid volume (PLV) of the spray, provide a unique set of time-resolved validation data for direct fuel injection simulations. At conditions ranging from flaring to mild and minimal flash boiling, we show that switching to the new relaxation time improves the agreement with the measured PLV profiles with respect to the standard empirical model. Particularly at flaring conditions, the predicted increase in gas cooling caused by rapid vapor production is shown to be more consistent with the observed boil-off.

42 ENGINEERING↗

Cofactor Complexes of DesD, a Model Enzyme in the Virulence-related NIS Synthetase Family

The understudied nonribosomal-peptide-synthetase-independent siderophore (NIS) synthetase family has been increasingly associated with virulence in bacterial species due to its key role in the synthesis of hydroxamate and carboxylate "stealth" siderophores. We have identified a model family member, DesD, from Streptomyces coelicolor , to structurally characterize using a combination of a wild-type and a Arg306Gln variant in apo , cofactor product AMP-bound, and cofactor reactant ATP-bound complexes. The kinetics in the family has been limited by solubility and reporter assays, so we have developed a label-free kinetics assay utilizing a single-injection isothermal-titration-calorimetry-based method. We report second-order rate constants that are 50 times higher than the previous estimations for DesD. Our Arg306Gln DesD variant was also tested under identical buffer and substrate conditions, and its undetectable activity was confirmed. These are the first reported structures for DesD, and they describe the critical cofactor coordination. This is also the first label-free assay to unambiguously determine the kinetics for an NIS synthetase.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Multi-channel front-end ASIC for a 3D position-sensitive detector

Arrays of 3D position-sensitive detectors (3DPSD), operating at room temperature and using cadmium zinc telluride (CZT) and thallium bromide (TIBr) sensors, are suitable for gamma-ray spectrometry in many applications. One detector configuration, the 3D position-sensitive Virtual Frisch-Grid detector (VFG), is particularly advantageous for integrating into large area arrays. The signals generated inside each detector of the array are captured with the anode, cathode and four pads that enable the reconstruction of the position and energy of the ionizing interaction by measurements of amplitude and timing of the signals. For these applications, a low-noise front-end ASIC has been developed, capable of processing bipolar signals (needed because of AC-coupling of certain electrodes). The ASIC can be coupled to an ADC in order to form a compound “waveform digitizer” capable of post-processing the analog signals and determining amplitude and timing information. This paper describes a 32-channel front-end ASIC that is suitable for reading out a 3 × 3 or 4 × 4 element matrix in the VFG configuration. Each channel is composed of a low-noise charge amplifier with an adaptive continuous reset feedback circuit suitable for both positive and negative charge, a first order shaper and a single-to-differential converter output stage. Voltage and current references are all internally generated by 10-bit DACs and the chip is fully controllable with the I 2 C communication protocol. The readout channel response has been verified using the implemented injection circuit. Linear behavior up to ~75 ke ± with the gain of ~80 mV/fC, and up to ~200 ke ± with the gain of ~30 mV/fC was demonstrated. In conclusion, the first test result waveforms using a 137 Cs radioactive source on a 5 × 5 × 12 mm 3 TIBr crystal are reported.

47 OTHER INSTRUMENTATION↗

VTR Casting Furnace Conceptual Design

This TEV describes the development of a conceptual design for a fuel casting system to be used in the development and demonstration of fuel designs for the new Versatile Test Reactor (VTR). This system will be installed in the Fuel Manufacturing Facility (FMF). The system will be in a shielded glovebox and will be used to melt fuel materials and injection cast these materials into fuel slugs, which will further be used to fabricate fuel elements for the VTR. This TEV covers only the injection casting system itself. Operations such as removing the castings from the injection molds, trimming of the castings, and installation of the castings into fuel element cladding are beyond the scope of the TEV. The conceptual design herein is principally concerned with the mechanical portion of the casting system and does not include details of the control or power supply systems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Line spread instrumentation for propagation measurements

A line spread device capable of yielding direct measure of a laser beam's line spread function (LSF) was developed and employed in propagation tests conducted in a wind tunnel to examine optimal acoustical suppression techniques for laser cavities exposed to simulated aircraft aerodynamic environments. Measurements were made on various aerodynamic fences and cavity air injection techniques that effect the LSF of a propagating laser. Using the quiescent tunnel as a control, the relative effect of each technique on laser beam quality was determined. The optical instrument employed enabled the comparison of relative beam intensity for each fence or mass injection. It was found that fence height had little effect on beam quality but fence porosity had a marked effect, i.e., 58% porosity alleviated cavity resonance and degraded the beam the least. Mass injection had little effect on the beam LSF. The use of a direct LSF measuring device proved to be a viable means of determining aerodynamic seeing qualities of flow fields.

Bailey, W. H., Jr.↗

Scaling wake-particle interactions for aerial applications research

The differential equation for the trajectory of a spherical particle injected into an aircraft wake was developed and the proper scaling relations extracted. After some simplification a convenient set of similarity parameters was established. Using these similarity parameters a scale model test program was designed and performed in the NASA Langley vortex research facility. The results of the tests demonstrated the validity of the similarity parameters in conducting scale model testing for aerial application research.

Ormsbee, A. I.↗

Catalytic ignition of hydrogen and oxygen propellants

An experimental program was conducted to evaluate the catalytic ignition of gaseous hydrogen and oxygen propellants. Shell 405 granular catalyst and a monolithic sponge catalyst were tested. Mixture ratio, mass flow rate, propellant temperature, and back pressure were varied parametrically in testing to determine the operational limits of the catalytic igniter. The test results show that the gaseous hydrogen and oxygen propellant combination can be ignited catalytically using Shell 405 catalyst over a wide range of mixture ratios, mass flow rates, and propellant injection temperatures. These operating conditions must be optimized to ensure reliable ignition for an extended period of time. A cyclic life of nearly 2000, 2 sec pulses at nominal operating conditions was demonstrated with the catalytic igniter. The results of the experimental program and the established operational limits for a catalytic igniter using the Shell 405 catalyst are presented.

Zurawski, Robert L.↗

Catalytic ignition of hydrogen and oxygen propellants

An experimental program was conducted to evaluate the catalytic ignition of gaseous hydrogen and oxygen propellants. Shell 405 granular catalyst and a monolithic sponge catalyst were tested. Mixture ratio, mass flow rate, propellant temperature, and back pressure were varied parametrically in testing to determine the operational limits of the catalytic igniter. The test results show that the gaseous hydrogen and oxygen propellant combination can be ignited catalytically using Shell 405 catalyst over a wide range of mixture ratios, mass flow rates, and propellant injection temperatures. These operating conditions must be optimized to ensure reliable ignition for an extended period of time. A cyclic life of nearly 2000, 2 sec pulses at nominal operating conditions was demonstrated with the catalytic igniter. The results of the experimental program and the established operational limits for a catalytic igniter using the Shell 405 catalysts are presented.

Zurawski, Robert L.↗

Ignition delays, heats of combustion, and reaction rates of aluminum alkyl derivatives used as ignition and combustion enhancers for supersonic combustors

The work was based on adapting an apparatus and procedure developed at Southwest Research Institute for rating the ignition quality of fuels for diesel engines. Aluminum alkyls and various Lewis-base adducts of these materials, both neat and mixed 50/50 with pure JP-10 hydrocarbon, were injected into the combustion bomb using a high-pressure injection system. The bomb was pre-charged with air that was set at various initial temperatures and pressures for constant oxygen density. The ignition delay times were determined for the test materials at these different initial conditions. The data are presented in absolute terms as well as comparisons with the parent alkyls. The relative heats of reaction of the various test materials were estimated based on a computation of the heat release, using the pressure data recorded during combustion in the bomb. In addition, the global reaction rates for each material were compared at a selected tmperature and pressure.

Ryan, T. W., III↗

Corrugated Quantum Well Infrared Photodetector Focal Plane Array Test Results

The corrugated quantum-well infrared photodetector (C-QWIP) uses total internal reflection to couple normal incident light into the optically active quantum wells. The coupling efficiency has been shown to be relatively independent of the pixel size and wavelength thus making the C-QWIP a candidate for detectors over the entire infrared spectrum. The broadband coupling efficiency of the C-QWIP makes it an ideal candidate for multiwavelength detectors. We fabricated and tested C-QWIP focal plane arrays (FPAs) with cutoff wavelengths of 11.2 and 16.2 micrometers. Each FPA has 256 x 256 pixels that are bump-bonded to a direct injection readout circuit. Both FPAs provided infrared imagery with good aesthetic attributes. For the 11.2-micrometers FPA, background-limited performance (BLIP) was observed at 60 K with f/3 optics. For the 16.2-micrometers FPA, BLIP was observed at 38 K. Besides the reduction of dark current in C-QWIP structures, the measured internal quantum efficiency (eta) remains to be high. The values for responsivity and quantum efficiency obtained from the FPA results agree well with those measured for single devices.

Goldberg, A.↗

Hydrogen/Air Fuel Nozzle Emissions Experiments

The use of hydrogen combustion for aircraft gas turbine engines provides significant opportunities to reduce harmful exhaust emissions. Hydrogen has many advantages (no CO2 production, high reaction rates, high heating value, and future availability), along with some disadvantages (high current cost of production and storage, high volume per BTU, and an unknown safety profile when in wide use). One of the primary reasons for switching to hydrogen is the elimination of CO2 emissions. Also, with hydrogen, design challenges such as fuel coking in the fuel nozzle and particulate emissions are no longer an issue. However, because it takes place at high temperatures, hydrogen-air combustion can still produce significant levels of NOx emissions. Much of the current research into conventional hydrocarbon-fueled aircraft gas turbine combustors is focused on NOx reduction methods. The Zero CO2 Emission Technology (ZCET) hydrogen combustion project will focus on meeting the Office of Aerospace Technology goal 2 within pillar one for Global Civil Aviation reducing the emissions of future aircraft by a factor of 3 within 10 years and by a factor of 5 within 25 years. Recent advances in hydrocarbon-based gas turbine combustion components have expanded the horizons for fuel nozzle development. Both new fluid designs and manufacturing technologies have led to the development of fuel nozzles that significantly reduce aircraft emissions. The goal of the ZCET program is to mesh the current technology of Lean Direct Injection and rocket injectors to provide quick mixing, low emissions, and high-performance fuel nozzle designs. An experimental program is planned to investigate the fuel nozzle concepts in a flametube test rig. Currently, a hydrogen system is being installed in cell 23 at NASA Glenn Research Center's Research Combustion Laboratory. Testing will be conducted on a variety of fuel nozzle concepts up to combustion pressures of 350 psia and inlet air temperatures of 1200 F. Computational fluid dynamics calculations, with the Glenn developed National Combustor Code, are being performed to optimize the fuel nozzle designs.

Smith, Timothy D.↗