Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Image-Driven Hybrid Structural Analysis Based on Continuum Point Cloud Method with Boundary Capturing Technique

Conventional approaches for the structural health monitoring of infrastructures often rely on physical sensors or targets attached to structural members, which require considerable preparation, maintenance, and operational effort, including continuous on-site adjustments. This paper presents an image-driven hybrid structural analysis technique that combines digital image processing (DIP) and regression analysis with a continuum point cloud method (CPCM) built on a particle-based strong formulation. Polynomial regressions capture the boundary shape change due to the structural loading and precisely identify the edge and corner coordinates of the deformed structure. The captured edge profiles are transformed into essential boundary conditions. This allows the construction of a strongly formulated boundary value problem (BVP), classified as the Dirichlet problem. Capturing boundary conditions from the digital image is novel, although a similar approach was applied to the point cloud data. It was shown that the CPCM is more efficient in this hybrid simulation framework than the weak-form-based numerical schemes. Unlike the finite element method (FEM), it can avoid aligning boundary nodes with regression points. A three-point bending test of a rubber beam was simulated to validate the developed technique. The simulation results were benchmarked against numerical results by ANSYS and various relevant numerical schemes. The technique can effectively solve the Dirichlet-type BVP, yielding accurate deformation, stress, and strain values across the entire problem domain when employing a linear strain model and increasing the number of CPCM nodes. In addition, comparative analysis with conventional displacement tracking techniques verifies the developed technique’s robustness. The proposed technique effectively circumvents the inherent limitations of traditional monitoring methods resulting from the reliance on physical gauges or target markers so that a robust and non-contact solution for remote structural health monitoring in real-scale infrastructures can be provided, even in unfavorable experimental environments.

Chemistry↗

Comfort in High-Performance Homes in a Hot-Humid Climate

TO5 2.3.2: Large-Scale Temperature Study Although space-conditioning systems are required to meet standards such as those in the Air Conditioning Contractors of America (ACCA) Manual RS (Rutkowski 1997) and the ASHRAE Standard 55 (ASHRAE 2013) comfort criteria, little is known about how space-conditioning systems are actually operating in the field and if these systems are meeting those standards. Unconventional space-conditioning systems may be necessary for low-load homes in the future. It is important to know how current systems are functioning in existing homes and to what temperatures occupants typically set the thermostats in their homes. The U.S. Department of Energy's Building America research team IBACOS set out to find some answers. By using low-cost data loggers and occupant surveys to monitor 37 single-family homes that have standard heating, ventilating, and air-conditioning (HVAC) equipment, the team gained insight into how sensitive occupants are to comfort in their homes relative to the ACCA and ASHRAE standards. This study focused on one climate zone (hot-humid); however, future studies may find differences among occupants- ideas of thermal comfort in other climate zones. Data were collected from installed sensors during a 2-month period from late August 2014 through late October 2014. The final aspect of this project was to review the business metrics associated with builders involved in a comfort and performance guarantee program. The results of this study-taken as an aggregate-show that the homes provided room-to-room temperature differences less than 6 degrees F 95% of the time. Temperature differences were less than 4 degrees F 80% of the time. Some homes showed better or worse performance. On average, two-story homes had a 3.3 degrees F temperature difference between rooms; single-story homes had an average of a 2.2 degrees F temperature difference between rooms. Occupants who did not use programmable thermostats had an average set point of 75 degrees F. Homes in which the thermostats were programmed with a setback schedule showed a median baseline temperature value of 74 degrees F and had a median afternoon setback of 75 degrees F. System runtime was analyzed and showed that the room-to-room temperature uniformity in some homes worsened during an on cycle, whereas the uniformity improved in other homes. That is, when the system was running, some rooms were receiving too much or too little air relative to the rest of the house, and the temperatures in those rooms were moving away from the temperatures of the other rooms in the house. Finally, analysis of the thermostat data shows a wide degree of variability among homes in the study. Interpretation of the measured data suggests that 21 occupants made no regular adjustments to the thermostats in their homes, seven had regular setbacks, seven showed varying setbacks, and 10 appeared to follow no pattern (with random adjustments). Ultimately, the data show that current systems are maintaining expected levels of comfort. As expected, it is more challenging to maintain a uniform temperature in all rooms of two-story homes, and future systems should address this issue. Furthermore, the data show that the majority of homes maintained relative humidity levels below 60% without any supplemental dehumidification

ACCA Manual RS↗

Temperature and Strain Sensing Characteristics of a 128° YX-Cut LiNbO 3 Rayleigh-Mode SAW Sensor From Room to Cryogenic Temperatures

Accurate, passive, and wireless monitoring of cryogenic hardware is essential for high-energy physics, space propulsion, and biomedical instrumentation. Here, this study quantifies the coupled temperature-strain behavior of Rayleigh-mode surface acoustic-wave (SAW) delay-line sensors fabricated on 128° YX-cut LiNbO 3 . A nonlinear finite element (FE) model incorporating Varshni-based elastic constants, higher-order thermal expansion, and temperature-dependent piezo- and dielectric coefficients was developed and validated experimentally between 280K and 80K. Free-standing (first test condition) and bonded/wired (second test condition) devices exhibited indistinguishable thermal responses; the average temperature coefficient of delay (TCD) in the critical cryogenic range from 130K down to 80K differed by only 0.15 ppm/K (0.32%), confirming that bonding-induced stress is negligible. Over 280-80K the measured TCD was 61.77 ppm/K, while the FE model predicted an equivalent temperature coefficient of frequency (TCF) of −62.74 ppm/K with an overall coefficient of determination R2 = 0.998. In the critical cryogenic interval 130-80K the TCD fell to 47.66 ppm/K, indicating improved thermal stability at low temperature. Controlled loading (0-300 με) revealed a strain coefficient of delay (SCD) that rises from 0.53 ± 0.02 ppm/με at 300K to 1.05 ± 0.02 ppm/με at 80K. This modest sensitivity confirms that, for temperature sensing, strain is a second-order perturbation above 135K but must be compensated at deeper cryogenic levels. Overall, this work establishes a predictive multiphysics model together with repeatable wired measurements that confirm the suitability of SAW sensors for temperature and strain monitoring in extreme cryogenic environments, while also providing a baseline for future wireless implementations.

25 ENERGY STORAGE↗

Implementation of Remaining Useful Lifetime Transformer Models in the Fleet-Wide Prognostic and Health Management Suite

Research and development efforts are required to address aging and reliability concerns of the existing fleet of nuclear power plants. As most plants continue to operate beyond the license life (i.e., towards 60 or 80 years), plant components are more likely to incur age-related degradation mechanisms. To assess and manage the health of aging plant assets across the nuclear industry, the Electric Power Research Institute has developed a web-based Fleet-Wide Prognostic and Health Management (FW-PHM) Suite for diagnosis and prognosis. FW-PHM is a set of web-based diagnostic and prognostic tools and databases, comprised of the Diagnostic Advisor, the Asset Fault Signature Database, the Remaining Useful Life Advisor, and the Remaining Useful Life Database, that serves as an integrated health monitoring architecture. The main focus of this paper is the implementation of prognostic models for generator step-up transformers in the FW-PHM Suite. One prognostic model discussed is based on the functional relationship between degree of polymerization, (the most commonly used metrics to assess the health of the winding insulation in a transformer) and furfural concentration in the insulating oil. The other model is based on thermal-induced degradation of the transformer insulation. By utilizing transformer loading information, established thermal models are used to estimate the hot spot temperature inside the transformer winding. Both models are implemented in the Remaining Useful Life Database of the FW-PHM Suite. The Remaining Useful Life Advisor utilizes the implemented prognostic models to estimate the remaining useful life of the paper winding insulation in the transformer based on actual oil testing and operational data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Development of an Integrated Residential Heating, Ventilation, Cooling, and Dehumidification System for Residences

The Need and the Opportunity Codes such as ASHRAE 90.2 and IECC, and programs such as Energy Star and Builders Challenge, are causing new homes to be built to higher performance standards. As a result sensible cooling loads in new homes are going down, but indoor air quality prerogatives are causing ventilation rates and moisture loads to increase in humid climates. Conventional air conditioners are unable to provide the low sensible heat ratios that are needed to efficiently cool and dehumidify homes since dehumidification potential is strongly correlated with cooling system operating hours. The project team saw an opportunity to develop a system that is at least as effective as a conventional air conditioner plus dehumidifier, removes moisture without increasing the sensible load, reduces equipment cost by integrating components, and simplifies installation. Project Overview Prime contractor Davis Energy Group led a team in developing an Integrated Heating, Ventilation, Cooling, and Dehumidification (I-HVCD) system under the DOE SBIR program. Phase I and II SBIR project activities ran from July 2003 through December 2007. Tasks included: (1) Mechanical Design and Prototyping; (2) Controls Development; (3) Laboratory and Field Testing; and (4) Commercialization Activities Technology Description. Key components of the prototype I-HVCD system include an evaporator coil assembly, return and outdoor air damper, and controls. These are used in conjunction with conventional components that include a variable speed air handler or furnace, and a two-stage condensing unit. I-HVCD controls enable the system to operate in three distinct cooling modes to respond to indoor temperature and relative humidity (RH) levels. When sensible cooling loads are high, the system operates similar to a conventional system but varies supply airflow in response to indoor RH. In the second mode airflow is further reduced, and the reheat coil adds heat to the supply air. In the third mode, the reheat coil adds additional heat to maintain the supply air temperature close to the return air temperature (100% latent cooling). Project Outcomes Key Phase II objectives were to develop a pre-production version of the system and to demonstrate its performance in an actual house. The system was first tested in the laboratory and subsequently underwent field-testing at a new house in Gainesville, Florida. Field testing began in 2006 with monitoring of a 'conventional best practices' system that included a two stage air conditioner and Energy Star dehumidifier. In September 2007, the I-HVCD components were installed for testing. Both systems maintained uniform indoor temperatures, but indoor RH control was considerably better with the I-HVCD system. The daily variation from average indoor humidity conditions was less than 2% for the I-HVCD vs. 5-7% for the base case system. Data showed that the energy use of the two systems was comparable. Preliminary installed cost estimates suggest that production costs for the current I-HVCD integrated design would likely be lower than for competing systems that include a high efficiency air conditioner, dehumidifier, and fresh air ventilation system. Project Benefits This project verified that the I-HVCD refrigeration compacts are compact (for easy installation and retrofit) and can be installed with air conditioning equipment from a variety of manufacturers. Project results confirmed that the system can provide precise indoor temperature and RH control under a variety of climate conditions. The I-HVCD integrated approach offers numerous benefits including integrated control, easier installation, and reduced equipment maintenance needs. Work completed under this project represents a significant step towards product commercialization. Improved indoor RH control and fresh air ventilation are system attributes that will become increasingly important in the years ahead as building envelopes improve and sensible cooling loads continue to fall. Technologies like I-HVCD will be instrumental in meeting goals set by Building America and other programs to reduce energy use while improving the indoor environment. Next Steps The following steps are needed to bring the product to commercialization: (1) Value engineering to reduce costs; (2) Addition of zoning capability to improve marketability; (3) Fabrication and testing of additional prototypes; and (4) Identification of a manufacturer. Initial efforts to interest large air conditioner manufacturers has shown some interest, but the preferred path to market may be to employ a boutique manufacturer that markets to HVAC contractors. Distribution of the results of this work will improve opportunities for attracting manufacturers. Additional funding is needed to prepare the product for this final step.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Bridge Testing With Ground-Based Interferometric Radar: Experimental Results

The research of innovative non-contact techniques aimed at the vibration measurement of civil engineering structures (also for damage detection and structural health monitoring) is continuously directed to the optimization of measures and methods. Ground-Based Radar Interferometry (GBRI) represents the more recent technique available for static and dynamic control of structures and ground movements.Dynamic testing of bridges and buildings in operational conditions are currently performed: (a) to assess the conformity of the structure to the project design at the end of construction; (b) to identify the modal parameters (i.e. natural frequencies, mode shapes and damping ratios) and to check the variation of any modal parameters over the years; (c) to evaluate the amplitude of the structural response to special load conditions (i.e. strong winds, earthquakes, heavy railway or roadway loads). If such tests are carried out by using a non-contact technique (like GBRI), the classical issues of contact sensors (like accelerometers) are easily overtaken.This paper presents and discusses the results of various tests carried out on full-scale bridges by using a Stepped Frequency-Continuous Wave radar system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A critical view on microplastic quantification in aquatic organisms

Microplastics, plastic particles and fragments smaller than 5 mm, are ubiquitous in the marine environment. Ingestion and accumulation of microplastics have previously been demonstrated for diverse marine species ranging from zooplankton to bivalves and fish, implying the potential for microplastics to accumulate in the marine food web. In this way, microplastics can potentially impact food safety and human health. Although a few methods to quantify microplastics in biota have been described, no comparison and/or intercalibration of these techniques have been performed. Here we conducted a literature review on all available extraction and quantification methods. Two of these methods, involving wet acid destruction, were used to evaluate the presence of microplastics in field-collected mussels (Mytilus galloprovincialis) from three different “hotspot” locations in Europe (Po estuary, Italy; Tagus estuary, Portugal; Ebro estuary, Spain). An average of 0.18±0.14 total microplastics g{sup −1} w.w. for the Acid mix Method and 0.12±0.04 total microplastics g{sup −1} w.w. for the Nitric acid Method was established. Additionally, in a pilot study an average load of 0.13±0.14 total microplastics g{sup −1} w.w. was recorded in commercial mussels (Mytilus edulis and M. galloprovincialis) from five European countries (France, Italy, Denmark, Spain and The Netherlands). A detailed analysis and comparison of methods indicated the need for further research to develop a standardised operating protocol for microplastic quantification and monitoring.

54 ENVIRONMENTAL SCIENCES↗

Mining Smart Meter Data to Enhance Distribution Grid Observability for Behind-the-Meter Load Control: Significantly improving system situational awareness and providing valuable insights

Distributed Energy Resources (DERs) are playing an increasingly important role in power systems. In 2023, five categories of DERs-distributed solar, electric vehicles (EVs), energy storage, residential smart thermostats, and small-scale combined heat and power-are expected to contribute about 104 GW to the U.S. summer peak (see GTM, 2018). With the increasing integration of DERs in power distribution systems, distributed load control is imperative to smooth the fluctuations that they introduce. However, a main challenge is that distribution systems lack systematic situational awareness because of their limited sensors. Furthermore, most customer-level behind-the-meter (BTM) DERs, such as rooftop photovoltaics (PVs), are being integrated into distribution systems, which complicates the system monitoring and control. Furthermore, enhanced electric grid monitoring is needed to promote renewable integration while ensuring reliability, but current approaches rely on expensive sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

First Spectroscopic Results with Tin Limiter on FTU Plasma

Since the end of 2016 experiments were performed on FTU with a tin limiter, for testing liquid metals under reactor relevant thermal load up to 17 MW/m{sup 2} in nearly stationary conditions. FTU is the first tokamak in the world operating with a liquid tin limiter and one of the pioneers in liquid metal application. The preliminary analysis of the experimental data has been focused in detecting the presence of tin in the discharge: suitable monitors are the spectroscopic diagnostics in the visible and UV ranges. The experimental observation of the tin spectral lines represents a new goal for extending the database of atomic nuclear data in the plasma tokamak research. In particular, 607.8 and 645.3 nm spectral lines of SnII have been observed. In addition, all the expected spectral lines in VUV range have been detected, 20.4 nm of SnXXI and 21.9 nm and 27.6 nm of SnXXII.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

RSRA sixth scale wind tunnel test

The sixth scale model of the Sikorsky/NASA/Army rotor systems research aircraft was tested in an 18-foot section of a large subsonic wind tunnel for the purpose of obtaining basic data in the areas of performance, stability, and body surface loads. The model was mounted in the tunnel on the struts arranged in tandem. Basic testing was limited to forward flight with angles of yaw from -20 to +20 degrees and angles of attack from -20 to +25 degrees. Tunnel test speeds were varied up to 172 knots (q = 96 psf). Test data were monitored through a high speed static data acquisition system, linked to a PDP-6 computer. This system provided immediate records of angle of attack, angle of yaw, six component force and moment data, and static and total pressure information. The wind tunnel model was constructed of aluminum structural members with aluminum, fiberglass, and wood skins. Tabulated force and moment data, flow visualization photographs, tabulated surface pressure data are presented for the basic helicopter and compound configurations. Limited discussions of the results of the test are included.

Flemming, R.↗

A New Approach to Overcoming Spatial Aliasing in Structural Damage Detection

Aircraft, reusable launch vehicles,unmanned aircraft, and other advanced structures are being built using lightweight composite materials/metals with design safety factors as low as 1.25. These advanced structures operate in uncertain and severe environments and are susceptible to damage such as delamination, fiber/matrix damage, hydrothermal strain in composite materials, and fatigue and cracking in metals. To ensure human safety and load-bearing integrity these structures must be inspected to detect and locate often invisible damage and faults before they become catastrophic. Conventional methods of non-destructive evaluation sometimes miss significant damage and are time consuming and expensive to perform. In contrast, vibrometry or vibration signature techniques are a global method of structural integrity monitoring that potentially can efficiently detect damage on large structures, including damage that is away from sensor locations, and in the interior of structures. However, a barrier problem in damage detection using vibration measurements is the need to measure the vibration response at a large number of points on the structure. Typically, model reduction or expansion procedures such as Guyan reduction or dynamic expansion are attempted to overcome the problem of insufficient measurements or spatial aliasing. These approaches depend on using information from the healthy model, and thus put error into the reduction used to represent the damaged structure. In this paper, a Frequency Response Function technique is used to detect damage to a fixed-free beam. The technique uses measured frequency response functions from the healthy structure as reference data, and then monitors vibration measurements during the life of the structure to detect damage. In an analytical simulation using a finite-element model of a beam, damage was located using only sparse measurements because the technique uses both rotation and translation measurements from the damaged structure.

Schulz, Mark J.↗

Detecting Cracks in Ceramic Matrix Composites by Electrical Resistance

The majority of damage in SiC/SiC ceramic matrix composites subjected to monotonic tensile loads is in the form of distributed matrix cracks. These cracks initiate near stress concentrations, such as 90o fiber tows or large matrix pores and continue to accumulate with additional stress until matrix crack saturation is achieved. Such damage is difficult to detect with conventional nondestructive evaluation techniques (immersion ultrasonics, x-ray, etc.). Monitoring a specimen.s electrical resistance change provides an indirect approach for monitoring matrix crack density. Sylramic-iBN fiber- reinforced SiC composites with a melt infiltrated (MI) matrix were tensile tested at room temperature. Results showed an increase in resistance of more than 500% prior to fracture, which can be detected either in situ or post-damage. A relationship between resistance change and matrix crack density was also determined.

Smith, Craig↗

Modeling Smart Microgrids for the Developing World with Probabilistic Supply and Demand Inputs

Developing world microgrids often balance insufficient supply with growing, unpredictable demand. Deterministic and probabilistic simulators exist to model these microgrids, and each focuses on different technical aspects. With the addition of smart meters into microgrids, monitoring and control is now available at high granularity, which enriches microgrid planning and operation. This research is designing a new simulator to model smart microgrids with discrete probability distributions as supply and demand inputs. In our model, smart meters allow real-time power clipping for demand side management, effectively smoothing the system load curve as needed. To compare clipping schemes for grid operation and generation mixes for planning, we aggregate inputs by convolution then compute expected energy sold and probability of avoiding power cuts. The simulator plots these values for different combinations of power clipping threshold and number of customers clipped.

13 HYDRO ENERGY↗

Resonant Kicker System Development at SLAC

The design and installation of the Linear Coherent Light Source [1] at SLAC National Accelerator Laboratory has included the development of a kicker system for selective beam bunch dumping. The kicker is based on an LC resonant topology formed by the 50 uF energy storage capacitor and the 64 uH air core magnet load which has a sinusoidal pulse period of 400us. The maximum magnet current is 500 A. The circuit is weakly damped, allowing most of the magnet energy to be recovered in the energy storage capacitor. The kicker runs at a repetition rate of 120Hz. A PLC-based control system provides remote control and monitoring of the kicker via EPICS protocol. Fast timing and interlock signals are converted by discrete peak-detect and sample-hold circuits into DC signals that can be processed by the PLC. The design and experimental characterization of the system are presented.

43 PARTICLE ACCELERATORS↗

Progress of a Cross-Correlation Based Optical Strain Measurement Technique for Detecting Radial Growth on a Rotating Disk

The Aeronautical Sciences Project under NASA's Fundamental Aeronautics Program is interested in the development of novel measurement technologies, such as optical surface measurements for the in situ health monitoring of critical constituents of the internal flow path. In situ health monitoring has the potential to detect flaws, i.e. cracks in key components, such as engine turbine disks, before the flaws lead to catastrophic failure. The present study, aims to further validate and develop an optical strain measurement technique to measure the radial growth and strain field of an already cracked disk, mimicking the geometry of a sub-scale turbine engine disk, under loaded conditions in the NASA Glenn Research Center's High Precision Rotordynamics Laboratory. The technique offers potential fault detection by imaging an applied high-contrast random speckle pattern under unloaded and loaded conditions with a CCD camera. Spinning the cracked disk at high speeds (loaded conditions) induces an external load, resulting in a radial growth of the disk of approximately 50.0-μm in the flawed region and hence, a localized strain field. When imaging the cracked disk under static conditions, the disk will be undistorted; however, during rotation the cracked region will grow radially, thus causing the applied particle pattern to be 'shifted'. The resulting particle displacements between the two images is measured using the two-dimensional cross-correlation algorithms implemented in standard Particle Image Velocimetry (PIV) software to track the disk growth, which facilitates calculation of the localized strain field. A random particle distribution is adhered onto the surface of the cracked disk and two bench top experiments are carried out to evaluate the technique's ability to measure the induced particle displacements. The disk is shifted manually using a translation stage equipped with a fine micrometer and a hotplate is used to induce thermal growth of the disk, causing the particles to become shifted. For both experiments, reference and test images are acquired before and after the induced shifts, respectively, and then processed using PIV software. The controlled manual translation of the disk resulted in detection of the particle displacements accurate to ~1.75% of full scale and the thermal expansion experiment resulted in successful detection of the disk's thermal growth as compared to the calculated thermal expansion results. After validation of the technique through the induced shift experiments, the technique is implemented in the Rotordynamics Lab for preliminary assessment in a simulated engine environment. The discussion of the findings and plans for future work to improve upon the results are addressed in the paper.

rotordynamics↗

A preliminary user-friendly, digital console for the control room parameters supervision in old-generation Nuclear Plants

Improvements in the awareness of a system status is an essential requirement to achieve safety in every kind of plant. In particular, in the case of Nuclear Power Plants (NPPs), a progress is crucial to enhance the Human Machine Interface (HMI) in order to optimize monitoring and analyzing processes of NPP operational states. Firstly, as old-fashioned plants are concerned, an upgrading of the whole console instrumentation is desirable in order to replace an analog visualization with a full-digital system. In this work, we present a novel instrument able to interface the control console of a nuclear reactor, developed by using CompactRio, a National Instruments embedded architecture and its dedicated programming language. This real-time industrial controller composed by a real-time processor and FPGA modules has been programmed to visualize the parameters coming from the reactor, and to storage and reproduce significant conditions anytime. This choice has been made on the basis of the FPGA properties: high reliability, determinism, true parallelism and re-configurability, achieved by a simple programming method, based on LabVIEW real-time environment. The system architecture exploits the FPGA capabilities of implementing custom timing and triggering, hardware-based analysis and co-processing, and highest performance control algorithms. Data stored during the supervisory phase can be reproduced by loading data from a measurement file, re-enacting worthwhile operations or conditions. The system has been thought to be used in three different modes, namely Log File Mode, Supervisory Mode and Simulation Mode. The proposed system can be considered as a first step to develop a more complete Decision Support System (DSS): indeed this work is part of a wider project that includes the elaboration of intelligent agents and meta-theory approaches. A synoptic has been created to monitor every kind of action on the plant through an intuitive sight. Furthermore, another important aim of this work is the possibility to have a front panel available on a web interface: CompactRio acts as a remote server and it is accessible on a dedicated LAN. This supervisory system has been tested and validated on the basis of the real control console for the 1-MW TRIGA reactor RC-1 at the ENEA, Casaccia Research Center. In this paper we show some results obtained by recording each variable as the reactor reaches its maximum level of power. The choice of a research reactor for testing the developed system relies on its training and didactic importance for the education of plant operators: in this context a digital instrument can offer a better user-friendly tool for learning and training. It is worthwhile to remark that such a system does not interfere with the console instrumentation, the latter continuing to preserve the total control. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Addressing Coldwater Temperature Impairment in a Changing Climate

Climate change is concerning for fisheries professionals because increased water temperatures threaten coldwater habitats, which are vital to recreational and commercial fisheries and keystone species. The Clean Water Act provides a legal framework to identify and address water quality impairments including those associated with temperature. However, although this framework provides a basic strategy to identify impairments, develop total maximum daily loads, and reduce pollution, it does not explicitly consider the challenges of a changing climate in addressing water quality impairments. Clean Water Act administrators and fisheries professionals can facilitate temperature restoration planning and implementation using the Clean Water Act framework to link stakeholders to the management of coldwater resources. Stakeholder engagement and collaboration, robust local monitoring, and incorporating climate resilience into restoration planning and implementation will promote comprehensive management of temperature impairments and the effects of climate change on fisheries.

54 ENVIRONMENTAL SCIENCES↗