SEARCH · Search NASA
Results for “MAGNET SYSTEM”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Test and Development of a 10 MW 1.3 GHz Sheet Beam Klystron for the ILC
The SLAC National Accelerator Laboratory Klystron Department is developing a 10 MW, 5 Hz, 1.6 ms, 1.3 GHz plug-compatible Sheet-Beam Klystron as a less expensive and more compact alternative to the ILC baseline Multiple-Beam Klystron. Earlier this year a beam tester was constructed and began test. Device fabrication issues have complicated the analysis of the data collected from an intercepting cup for making beam quality measurements of the 130 A, 40-to-1 aspect ratio beam. Since the goal of the beam tester is to confirm 3d beam simulations it was necessary to rebuild the device in order to mitigate unwanted effects due to imperfect focusing construction. Measurements are underway to verify the results of this latest incarnation. Measurement will then be made of the beam after transporting through a drift tube and magnetic focusing system. In the klystron design, a TE oscillation was discovered during long simulation runs of the entire device which has since prompted two design changes to eliminate the beam disruption. The general theory of operation, the design choices made, and results of testing of these various devices will be discussed.
RF cavity chain and magnetic circuit for a 10-MW, 1.3 GHz, low-voltage multi-beam klystron
Explore the source record for details and available documents.
A Differential Algebraic Integration Algorithm for Symplectic Mappings in Systems with Three-Dimensional Magnetic Field
Explore the source record for details and available documents.
A New Precision Measurement System for Beam Transport Type Magnets
Explore the source record for details and available documents.
Vibrational Modes of the Pedestal Support System for the SLC Arc Magnets
Explore the source record for details and available documents.
THERMAL ANALYSIS OF THE RHIC ARC DIPOLE MAGNET COLD MASS WITH THE EIC BEAM SCREEN
The EIC will make use of the existing RHIC storage rings with their superconducting (SC) magnet arcs. A stain-less-steel beam screen with co-laminated copper and a thin amorphous carbon (aC) film on the inner surface will be installed in the beam pipe of the SC magnets. The copper will reduce the beam-induced resistive-wall (RW) heating from operation with the higher intensity EIC beams, that if not addressed would make the magnets quench. Limiting the RW heating is also important to achieve an adequately low vacuum level. The aC coating will reduce secondary electron yield which could also cause heating and limit in-tensity. Among all the RHIC SC magnets, the arc dipoles present the biggest challenge to the design and installation of beam screens. The arc dipoles, which make up for 78% (2.5 km) length of all SC magnets in RHIC, expect the larg-est RW heating due to their smallest aperture. These mag-nets are also the longest (9.45 m each), thus experiencing the largest temperature rise over their length, and have a large sagitta (48.5 mm) that increases the difficulty to in-stall the beam screen in place. This paper presents a de-tailed thermal analysis of the magnet-screen system.
High Thermal Conductivity Resin Systems for High Energy Physics Magnets
Explore the source record for details and available documents.
Phase I SBIR Final report - Magnet Power Supply for Tokamak Fusion System
Explore the source record for details and available documents.
The Astromag superconducting magnet facility configured for a free-flying satellite
The magnet parameters of a free-flying version of Astromag and the parameters of the space cryogenic system for the magnet are presented. Consideration is given to the free-flyer version of the Astromag magnet. The diameter of the magnet, its cryostat, the satellite and the two instruments is limited by the 4.27-m shroud diameter of the Atlas IIa. The magnet coil must use a stable reliable superconductor which can carry the full magnet current at 4.2 K at a peak induction in the coil of 7.5 T. The magnet must operate in the persistent mode. The changes in the overall design and operating requirements for the free-flying-design Astromag suggest that the coils, the cryogenic system, and the charging system can be simplified without a loss of required magnet function. Attention is given to switches, trim coils, and plumbing in the low field region between the coils; the magnet charging system and the quench protection system; and cooled helium supply to the magnet gas-cooled electrical leads.
A state of the art Lambertson septum magnet of the RHIC beam injection system
The beam injection system of the Relativistic Heavy Ion Collider (RHIC) is the last section of the beam transfer line which transports the beam from the Alternating Gradient Synchrotron (AGS) to RHIC and comes under the acronym AtR (AGS to RHIC). The Lambertson septum magnet is one of the magnetic elements of the RHIC injection system. This paper presents results from the 2D and 3D electromagnetic design of the RHIC Lambertson septum magnet which has unique design features to minimize the magnetic field at the circulated beam region including the fringe field regions at the entrance and exit of the magnet.
Floquet topological systems with flat bands: Edge modes, Berry curvature, and orbital magnetization
Results are presented for Floquet systems in two spatial dimensions where the Floquet driving breaks an effective time reversal symmetry. The driving protocol also induces flat bands that correspond to anomalous Floquet phases where the Chern number is zero and yet chiral edge modes exist. Analytic expressions for the edge modes, Berry curvature, and the orbital magnetization are derived for the flat bands. Results are also presented for the static Haldane model for parameters when the bands are flat. Floquet driving of the same model is shown to give rise to Chern insulators as well as anomalous Floquet phases. As a result, the orbital magnetization for these different topological phases are presented and are found to be enhanced at half filling by the broken particle-hole symmetry of the Haldane model.
Structural and magnetic phase transition in samarium hydrogen system SmH{sub x} (x=1, 2, 3)
We report ab-initio calculations for the structural and magnetic phase transition of SmH{sub x} (x= 1, 2, 3) using the Vienna ab-initio simulation package (VASP). The non-spin polarized (NSP) and spin polarized (SP) calculations are performed for these hydrides at normal and high pressure. It is found that these compounds are stable in ferromagnetic state at normal pressure. The calculated lattice parameters and bulk modulus of these hydrides are in good agreement with the available experimental results. A pressure-induced structural phase transition from cubic to hexagonal phase in SmH and SmH{sub 2} and hexagonal to cubic phase in SmH{sub 3} is predicted. A pressure-induced ferromagnetic to nonmagnetic phase transition is observed in SmH, SmH{sub 2} and SmH{sub 3} at the pressures of 104 GPa, 76 GPa and 81 GPa respectively. Ferromagnetism is quenched in mono, di and tri hydrides at high pressures.
Computer aided design of digital controller for radial active magnetic bearings
A five degree of freedom Active Magnetic Bearing (AMB) system is developed which is controlled by digital controllers. The model of the radial AMB system is linearized and the state equation is derived. Based on the state variables feedback theory, digital controllers are designed. The performance of the controllers are evaluated according to experimental results. The Computer Aided Design (CAD) method is used to design controllers for magnetic bearings. The controllers are implemented with a digital signal processing (DSP) system. The control algorithms are realized with real-time programs. It is very easy to change the controller by changing or modifying the programs. In order to identify the dynamic parameters of the controlled magnetic system, a special experiment was carried out. Also, the online Recursive Least Squares (RLS) parameter identification method is studied. It can be realized with the digital controllers. Online parameter identification is essential for the realization of an adaptive controller.
Quality of Intensity Modulated Radiation Therapy Treatment Plans Using a {sup 60}Co Magnetic Resonance Image Guidance Radiation Therapy System
Purpose: This work describes a commercial treatment planning system, its technical features, and its capabilities for creating {sup 60}Co intensity modulated radiation therapy (IMRT) treatment plans for a magnetic resonance image guidance radiation therapy (MR-IGRT) system. Methods and Materials: The ViewRay treatment planning system (Oakwood Village, OH) was used to create {sup 60}Co IMRT treatment plans for 33 cancer patients with disease in the abdominal, pelvic, thorax, and head and neck regions using physician-specified patient-specific target coverage and organ at risk (OAR) objectives. Backup plans using a third-party linear accelerator (linac)-based planning system were also created. Plans were evaluated by attending physicians and approved for treatment. The {sup 60}Co and linac plans were compared by evaluating conformity numbers (CN) with 100% and 95% of prescription reference doses and heterogeneity indices (HI) for planning target volumes (PTVs) and maximum, mean, and dose-volume histogram (DVH) values for OARs. Results: All {sup 60}Co IMRT plans achieved PTV coverage and OAR sparing that were similar to linac plans. PTV conformity for {sup 60}Co was within <1% and 3% of linac plans for 100% and 95% prescription reference isodoses, respectively, and heterogeneity was on average 4% greater. Comparisons of OAR mean dose showed generally better sparing with linac plans in the low-dose range <20 Gy, but comparable sparing for organs with mean doses >20 Gy. The mean doses for all {sup 60}Co plan OARs were within clinical tolerances. Conclusions: A commercial {sup 60}Co MR-IGRT device can produce highly conformal IMRT treatment plans similar in quality to linac IMRT for a variety of disease sites. Additional work is in progress to evaluate the clinical benefit of other novel features of this MR-IGRT system.
The Phase Diagram and Exotic Magnetostrictive Behaviors in Spinel Oxide Co(Fe1−xAlx)2O4 System
We report the magnetic and magnetostrictive behaviors of the pseudobinary ferrimagnetic spinel oxide system (1−x)CoFe2O4–xCoAl2O4 [Co(Fe1−xAlx)2O4], with one end-member being the ferrimagnetic CoFe2O4 and the other end-member being CoAl2O4 that is paramagnetic above 9.8 K. The temperature spectra of magnetization and magnetic susceptibility were employed to detect the magnetic transition temperatures and to determine the phase diagram of this system. Composition dependent and temperature dependent magnetostrictive behaviors reveal an exotic phase boundary that separates two ferrimagnetic states: At room temperature and under small magnetic fields (∼500 Oe), Fe-rich compositions exhibit negative magnetostriction while the Al-rich compositions exhibit positive magnetostriction though the values are small (<10 ppm). Moreover, the compositions around this phase boundary at room temperature (x = 0.35, 0.4, 0.45, 0.5) exhibit near-zero magnetostriction and enhanced magnetic susceptibility, which may be promising in the applications for magnetic cores, current sensors, or magnetic shielding materials.
Approach to Synchronization Control of Magnetic Bearings Using Fuzzy Logic
This paper presents a fuzzy-logic approach to the synthesis of synchronization control for magnetically suspended rotor system. The synchronization control enables a whirling rotor to undergo synchronous motion along the magnetic bearing axes; thereby avoiding the gyroscopic effect that degrade the stability of rotor systems when spinning at high speed. The control system features a fuzzy controller acting on the magnetic bearing device, in which the fuzzy inference system trained through fuzzy rules to minimize the differential errors between four bearing axes so that an error along one bearing axis can affect the overall control loop for the motion synchronization. Numerical simulations of synchronization control for the magnetically suspended rotor system are presented to show the effectiveness of the present approach.
A low temperature nonlinear optical rotational anisotropy spectrometer for the determination of crystallographic and electronic symmetries
Nonlinear optical generation from a crystalline material can reveal the symmetries of both its lattice structure and underlying ordered electronic phases and can therefore be exploited as a complementary technique to diffraction based scattering probes. Although this technique has been successfully used to study the lattice and magnetic structures of systems such as semiconductor surfaces, multiferroic crystals, magnetic thin films, and multilayers, challenging technical requirements have prevented its application to the plethora of complex electronic phases found in strongly correlated electron systems. These requirements include an ability to probe small bulk single crystals at the μm length scale, a need for sensitivity to the entire nonlinear optical susceptibility tensor, oblique light incidence reflection geometry, and incident light frequency tunability among others. These measurements are further complicated by the need for extreme sample environments such as ultra low temperatures, high magnetic fields, or high pressures. In this review we present a novel experimental construction using a rotating light scattering plane that meets all the aforementioned requirements. We demonstrate the efficacy of our scheme by making symmetry measurements on a μm scale facet of a small bulk single crystal of Sr{sub 2}IrO{sub 4} using optical second and third harmonic generation.