Search NASA⌕ Search

SEARCH · Search NASA

Results for “Model Counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Bowtie filters for dedicated breast CT: Analysis of bowtie filter material selection

Purpose: For a given bowtie filter design, both the selection of material and the physical design control the energy fluence, and consequently the dose distribution, in the object. Using three previously described bowtie filter designs, the goal of this work is to demonstrate the effect that different materials have on the bowtie filter performance measures. Methods: Three bowtie filter designs that compensate for one or more aspects of the beam-modifying effects due to the differences in path length in a projection have been designed. The nature of the designs allows for their realization using a variety of materials. The designs were based on a phantom, 14 cm in diameter, composed of 40% fibroglandular and 60% adipose tissue. Bowtie design #1 is based on single material spectral matching and produces nearly uniform spectral shape for radiation incident upon the detector. Bowtie design #2 uses the idea of basis-material decomposition to produce the same spectral shape and intensity at the detector, using two different materials. With bowtie design #3, it is possible to eliminate the beam hardening effect in the reconstructed image by adjusting the bowtie filter thickness so that the effective attenuation coefficient for every ray is the same. Seven different materials were chosen to represent a range of chemical compositions and densities. After calculation of construction parameters for each bowtie filter design, a bowtie filter was created using each of these materials (assuming reasonable construction parameters were obtained), resulting in a total of 26 bowtie filters modeled analytically and in the PENELOPE Monte Carlo simulation environment. Using the analytical model of each bowtie filter, design profiles were obtained and energy fluence as a function of fan-angle was calculated. Projection images with and without each bowtie filter design were also generated using PENELOPE and reconstructed using FBP. Parameters such as dose distribution, noise uniformity, and scatter were investigated. Results: Analytical calculations with and without each bowtie filter show that some materials for a given design produce bowtie filters that are too large for implementation in breast CT scanners or too small to accurately manufacture. Results also demonstrate the ability to manipulate the energy fluence distribution (dynamic range) by using different materials, or different combinations of materials, for a given bowtie filter design. This feature is especially advantageous when using photon counting detector technology. Monte Carlo simulation results from PENELOPE show that all studied material choices for bowtie design #2 achieve nearly uniform dose distribution, noise uniformity index less than 5%, and nearly uniform scatter-to-primary ratio. These same features can also be obtained using certain materials with bowtie designs #1 and #3. Conclusions: With the three bowtie filter designs used in this work, the selection of material is an important design consideration. An appropriate material choice can improve image quality, dose uniformity, and dynamic range.

60 APPLIED LIFE SCIENCES↗

Deployment of portable, modular gas samplers as part of an atmospheric tracer experiment

Underground nuclear explosions release noble gases into the atmosphere that can be detected to support international monitoring efforts. Atmospheric transport models help predict the movement of these gases over long distances, but struggle to predict the movement in the atmosphere local to the release. A field experiment was designed to monitor the movement of 127 Xe within a 5-km radius. Four gas samplers were deployed as part of this experiment to collect atmospheric samples at various distances from the release point. In conclusion, these samples were then analyzed in a near-field lab using a NaI detector and in an off-site lab using gamma-gamma coincidence and beta-gamma coincidence counting.

Radioxenon↗

Binding complexity and multiparty entanglement

We introduce “binding complexity”, a new notion of circuit complexity which quantifies the difficulty of distributing entanglement among multiple parties, each consisting of many local degrees of freedom. We define binding complexity of a given state as the minimal number of quantum gates that must act between parties to prepare it. To illustrate the new notion we compute it in a toy model for a scalar field theory, using certain multiparty entangled states which are analogous to configurations that are known in AdS/CFT to correspond to multiboundary wormholes. Pursuing this analogy, we show that our states can be prepared by the Euclidean path integral in (0 + 1)-dimensional quantum mechanics on graphs with wormhole-like structure. We compute the binding complexity of our states by adapting the Euler-Arnold approach to Nielsen’s geometrization of gate counting, and find a scaling with entropy that resembles a result for the interior volume of holographic multiboundary wormholes. We also compute the binding complexity of general coherent states in perturbation theory, and show that for “double-trace deformations” of the Hamiltonian the effects resemble expansion of a wormhole interior in holographic theories.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Renormalization-group equations of the LEFT at two loops: dimension-six baryon-number-violating operators

We present the second part of a systematic calculation of the two-loop anomalous dimensions for the low-energy effective field theory below the electroweak scale (LEFT): the baryon-number-violating sector at dimension six in the power counting. We obtain the results in two different schemes: in the algebraically consistent ’t Hooft-Veltman scheme for γ 5 , corrected for evanescent as well as chiral-symmetry-breaking effects through finite renormalizations; and in naive dimensional regularization, which in the considered sector of the theory does not lead to any ill-defined γ 5 -odd traces. Our results are of interest for a reanalysis of the constraints on physics beyond the Standard Model from proton-decay searches within an EFT framework at next-to-leading-logarithmic accuracy.

Baryon/Lepton Number Violation↗

Systematic errors in Sunyaev-Zeldovich surveys of galaxy cluster velocities

Galaxy cluster surveys compiled via the Sunyaev-Zeldovich Effect have the potential to place strong constraints on cosmology, and in particular the nature of dark energy. Here we consider cluster velocity surveys using kinetic Sunyaev-Zeldovich measurements. Cluster velocities closely trace the large-scale velocity field independent of cluster mass; we demonstrate that two useful cluster velocity statistics are nearly independent of cluster mass, in marked contrast to cluster number count statistics. On the other hand, cluster velocity determinations from three-band observations of Sunyaev-Zeldovich distortions can require additional cluster data or assumptions, and are complicated by microwave emission from dusty galaxies and radio sources, which may be correlated with clusters. Systematic errors in velocity due to these factors can give substantial biases in determination of dark energy parameters, although large cluster velocity surveys will contain enough information that the errors can be modeled using the data set itself, with little degradation in cosmological constraints.

79 ASTRONOMY AND ASTROPHYSICS↗

ARE ACTIVE GALACTIC NUCLEI THE SOLUTION TO THE EXCESS COSMIC RADIO BACKGROUND AT 1.4 GHz?

Recently, the ARCADE 2 experiment measured the cosmic radio background (CRB) and found the brightness temperature of the CRB at 1.4 GHz to be {approx}480 mK. Integrating the flux density from the observed 1.4 GHz radio source count produces a brightness temperature of {approx}100 mK-less than a quarter of the observed CRB at 1.4 GHz. Radio-quiet active galactic nuclei (AGNs) are a large fraction of the 1.4 GHz {mu}Jy sources and typically host significant star formation. Thus, it is possible that AGN and host star formation could be responsible for some fraction of the excess CRB at 1.4 GHz. Here, an X-ray background population synthesis model is used in conjunction with empirical radio to X-ray luminosity ratios to calculate the AGN contribution to the CRB at 1.4 GHz, including the emission from host star formation. It is found that AGN and host star formation contribute {approx}<9% of the CRB at 1.4 GHz. When all known 1.4 GHz radio source classes are considered, {approx}<60% of the CRB at 1.4 GHz is accounted for; therefore, it is necessary that either known radio sources evolve significantly at flux densities below current survey sensitivity limits or a new population of low flux density radio sources exist.

79 ASTRONOMY AND ASTROPHYSICS↗

Systematic approach to leptogenesis in nonequilibrium QFT: Vertex contribution to the CP-violating parameter

The generation of a baryon asymmetry via leptogenesis is usually studied by means of classical kinetic equations whose applicability to processes in the hot and expanding early universe is questionable. The approximations implied by the state-of-the-art description can be tested in a first-principle approach based on nonequilibrium field theory techniques. Here, we apply the Schwinger-Keldysh/Kadanoff-Baym formalism to a simple toy model of leptogenesis. We find that, within the toy model, medium effects increase the vertex contribution to the CP-violating parameter. At high temperatures it is a few times larger than in vacuum and asymptotically reaches the vacuum value as the temperature decreases. Contrary to the results obtained earlier in the framework of thermal field theory, the corrections are only linear in the particle number densities. An important feature of the Kadanoff-Baym formalism is that it is free of the double-counting problem, i.e. no need for real intermediate state subtraction arises. In particular, this means that the structure of the equations automatically ensures that the asymmetry vanishes in equilibrium. These results give a first glimpse into a number of new and interesting effects that can be studied in the framework of nonequilibrium field theory.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-T-301: Spectral Comparison of the Xoft and Zeiss 50 KVp X-Ray Systems

Purpose: To compare x-ray spectra of the 50 kVp Xoft Axxent™ and Zeiss INTRABEAM™ x-ray sources after filtration by saline-filled balloons applicators or spherical polymer applicators, respectively. Methods: Measurements were made for 3.5, 4.0 and 5.0 cm diameter applicators using an AmpTek model XR-100T-CdTe cadmium telluride spectrometer with 100 μm diameter collimating aperture and model PX4 digital pulse processor. Spectra were then corrected for escape processes using AmpTek XRF-FP Escape software. Both Axxent and INTRABEAM sources were operated at 50 kV and 40 μA to eliminate pulse saturation. The balloon or spherical applicator was placed in a centering fixture in contact with the collimator cap. The distance through the collimator housing from the applicator surface to the spectrometer's beryllium entrance window was nominally 52mm. Approximately 500,000 counts were collected for each spectrum. Results: Measured spectra in all cases had a broad Bremsstrahlung continuum with subtle differences in characteristic low energy x-rays lines from the different materials used for the anode thin films and substrates. After corrections for escape events average energies were calculated for spectra emerging from applicators. The average energies were 28.2 ±0.3 keV, 29.0±0.7 keV, and 31.7±0.9 keV for the 3.5, 4.0 and 5.0 cm diameter applicators, respectively. Differences in average energies ranged from 2.0 to 5.6% for these diameters. The mean energies of the spectra are more dependent on balloon size than on the delivery system used. Conclusion: Energy spectra at the surfaces of 3.5, 4.0 and 5.0 cm diameter applicators were measured for the Axxent and INTRABEAM x-ray systems were using a Cd-Te spectrometer. The average energies of the two x-ray systems for comparable applicator sizes were within 5.6%, and as little as 0.6 keV difference for the smaller applicator size. Research sponsored by Xoft, a subsidiary of ICAD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A “loop” shape descriptor and its application to automated segmentation of airways from CT scans

Purpose: A novel shape descriptor is presented to aid an automated identification of the airways depicted on computed tomography (CT) images. Methods: Instead of simplifying the tubular characteristic of the airways as an ideal mathematical cylindrical or circular shape, the proposed “loop” shape descriptor exploits the fact that the cross sections of any tubular structure (regardless of its regularity) always appear as a loop. In implementation, the authors first reconstruct the anatomical structures in volumetric CT as a three-dimensional surface model using the classical marching cubes algorithm. Then, the loop descriptor is applied to locate the airways with a concave loop cross section. To deal with the variation of the airway walls in density as depicted on CT images, a multiple threshold strategy is proposed. A publicly available chest CT database consisting of 20 CT scans, which was designed specifically for evaluating an airway segmentation algorithm, was used for quantitative performance assessment. Measures, including length, branch count, and generations, were computed under the aid of a skeletonization operation. Results: For the test dataset, the airway length ranged from 64.6 to 429.8 cm, the generation ranged from 7 to 11, and the branch number ranged from 48 to 312. These results were comparable to the performance of the state-of-the-art algorithms validated on the same dataset. Conclusions: The authors’ quantitative experiment demonstrated the feasibility and reliability of the developed shape descriptor in identifying lung airways.

60 APPLIED LIFE SCIENCES↗

Melanin, a promising radioprotector: Mechanisms of actions in a mice model

The radioprotective effect of extracellular melanin, a naturally occurring pigment, isolated from the fungus Gliocephalotrichum simplex was examined in BALB/C mice, and the probable mechanism of action was established. At an effective dose of 50 mg/kg body weight, melanin exhibited both prophylactic and mitigative activities, increasing the 30-day survival of mice by 100% and 60%, respectively, after exposure to radiation (7 Gy, whole body irradiation (WBI)). The protective activity of melanin was primarily due to inhibition of radiation-induced hematopoietic damages as evidenced by improvement in spleen parameters such as index, total cellularity, endogenous colony forming units, and maintenance of circulatory white blood cells and platelet counts. Melanin also reversed the radiation-induced decrease in ERK phosphorylation in splenic tissue, which may be the key feature in its radioprotective action. Additionally, our results indicated that the sustained activation of AKT, JNK and P38 proteins in splenic tissue of melanin pre-treated group may also play a secondary role. This was also supported by the fact that melanin could prevent apoptosis in splenic tissue by decreasing BAX/Bcl-XL ratio, and increasing the expressions of the proliferation markers (PCNA and Cyclin D1), compared to the radiation control group. Melanin also reduced the oxidative stress in hepatic tissue and abrogated immune imbalance by reducing the production of pro-inflammatory cytokines (IL6 and TNFα). In conclusion, our results confirmed that fungal melanin is a very effective radioprotector against WBI and the probable mechanisms of radioprotection are due to modulation in pro-survival (ERK) signaling, prevention of oxidative stress and immunomodulation. -- Highlights: ► Melanin showed promising radioprotection under pre and post irradiation condition. ► Melanin protects the hematopoietic system from radiation induced damage. ► Melanin modulates pro-survival pathways, immune system and prevents oxidative stress.

60 APPLIED LIFE SCIENCES↗

Collective excitations and low-energy ionization signatures of relativistic particles in silicon detectors

Abstract Solid-state detectors with a low energy threshold have several applications, including searches of non-relativistic halo dark-matter particles with sub-GeV masses. When searching for relativistic, beyond-the-Standard-Model particles with enhanced cross sections for small energy transfers, a small detector with a low energy threshold may have better sensitivity than a larger detector with a higher energy threshold. In this paper, we calculate the low-energy ionization spectrum from high-velocity particles scattering in a dielectric material. We consider the full material response including the excitation of bulk plasmons. We generalize the energy-loss function to relativistic kinematics, and benchmark existing tools used for halo dark-matter scattering against electron energy-loss spectroscopy data. Compared to calculations commonly used in the literature, such as the Photo-Absorption-Ionization model or the free-electron model, including collective effects shifts the recoil ionization spectrum towards higher energies, typically peaking around 4–6 electron-hole pairs. We apply our results to the three benchmark examples: millicharged particles produced in a beam, neutrinos with a magnetic dipole moment produced in a reactor, and upscattered dark-matter particles. Our results show that the proper inclusion of collective effects typically enhances a detector’s sensitivity to these particles, since detector backgrounds, such as dark counts, peak at lower energies.

Physics↗

Integrated Nondestructive Assay Systems to Estimate Plutonium in Spent Fuel Assemblies

An integrated nondestructive assay (NDA) system combining active (neutron generator) and passive neutron detection and passive gamma (PG) detection is being analyzed in order to estimate the amount of plutonium, verify initial enrichment, burnup, and cooling time, and detect partial defects in a spent fuel assembly (SFA). Active signals are measured using the differential die-away (DDA), delayed neutron (DN), and delayed gamma (DG) techniques. Passive signals are measured using total neutron (TN) counts and both gross and spectral resolved gamma counts. To quantify how a system of several NDA techniques is expected to perform, all of the relevant NDA techniques listed above were simulated as a function of various reactor conditions such as initial enrichment, burnup, cooling time, assembly shuffling pattern, reactor operating conditions (including temperature, pressure, and the presence of burnable poisons) by simulating the NDA response for five sets of light water reactor assemblies. In this study, we compare the performance of several exploratory model-fitting options (including neural networks, adaptive regression with splines, iterative bias reduction smoothing, projection pursuit regression, and regression with quadratic terms and interaction terms) to relate data simulated with measurement and model error effects from various subsets of the NDA techniques to the total Pu mass. Isotope masses for SFAs and expected detector responses (DRs) for several NDA techniques are simulated using MCNP, and the DRs become inputs to the fitting process. Such responses include eight signals from DDA, one from DN, one from TN, and up to seven from PG; the DG signal will be examined separately. Results are summarized using the root-mean-squared estimation error for plutonium mass in held-out subsets of the data for a range of model and measurement error variances. Different simulation assumptions lead to different spent fuel libraries relating DRs to Pu mass. Some results for training with one library and testing with another library are also given.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Simulations of Lithium-Based Neutron Coincidence Counter for Gd-Loaded Fuel

The Department of Energy Office of Nuclear Safeguards and Security (NA-241) is supporting the project Lithium-Based Alternative Neutron Detection Technology Coincidence Counting for Gd-loaded Fuels at Pacific Northwest National Laboratory for the development of a lithium-based neutron coincidence counter for nondestructively assaying Gd loaded nuclear fuel. This report provides results from MCNP simulations of a lithium-based coincidence counter for the possible measurement of Gd-loaded nuclear fuel. A comparison of lithium-based simulations and UNCL-II simulations with and without Gd loaded fuel is provided. A lithium-based model, referred to as PLNS3A-R1, showed strong promise for assaying Gd loaded fuel.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Modeling longitudinal INMA(1) with COM–Poisson innovation under non-stationarity: application to medical data

This paper introduces an observation-driven (OD) longitudinal integer-valued moving average model of order 1 (INMA(1)) with COM–Poisson innovations under non-stationary moment conditions. This new longitudinal model provides lot of practical flexibility in terms of modeling a wide range of over-, under-dispersion and any mixed level of dispersion. In this set-up, the model parameters of primary interest consist of the regression and dispersion effects while the serial autocorrelation parameters are treated as nuisance. A robust Generalized Quasi-Likelihood approach is formulated to estimate the different set of parameters. The performance of the estimating algorithm is assessed via Monte Carlo experiments under various combination of the serial and dispersion values and is compared with the existing adaptive generalized method of moments. Application to two medical data: epileptic seizures and polyposis counts are also illustrated.

97 MATHEMATICS AND COMPUTING↗

Signal, noise, and resolution in correlated fluctuations from snapshot small-angle x-ray scattering

It has been suggested that the three-dimensional structure of one particle may be reconstructed using the scattering from many identical, randomly oriented copies ab initio, without modeling or a priori information. This may be possible if these particles are frozen in either space or time, so that the conventional two-dimensional small-angle x-ray scattering (SAXS) distribution contains fluctuations and is no longer isotropic. We consider the magnitude of the correlated fluctuation SAXS (CFSAXS) signal for typical x-ray free-electron laser (XFEL) beam conditions and compare this against the errors derived with the inclusion of Poisson photon counting statistics. The resulting signal-to-noise ratio (SNR) is found to rapidly approach a limit independent of the number of particles contributing to each diffraction pattern, so that the addition of more particles to a ''single-particle-per-shot'' experiment may be of little value, apart from reducing solvent background. When the scattering power is significantly less than one photon per particle per Shannon pixel, the SNR grows in proportion to incident flux. We provide simulations for protein molecules in support of these analytical results, and discuss the effects of solvent background scatter. We consider the SNR dependence on resolution and particle size, and discuss the application of the method to glasses and liquids, and the implications of more powerful XFELs, smaller focused beams, and higher pulse repetition rates for this approach. We find that an accurate CFSAXS measurement may be acquired to subnanometer resolution for protein molecules if a 9-keV beam containing 10{sup 13} photons is focused to a {approx}100-nm spot diameter, provided that the effects of solvent background can be reduced sufficiently.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Geology of the One Earth Energy Site

The One Earth Energy site is one of two sites in the Illinois Storage Corridor (ISC) project. The objectives of the ISC project is to accelerate commercial deployment of carbon capture utilization and storage at two individual sites and receive approvals for Underground Injection Control (UIC) Class VI permits for construction at each site. At the One Earth Energy site, an extensive data collection program was undertaken, which included the drilling of a test well (One Earth Energy #1 [OEE #1]), four 2D seismic lines, and a small 3D seismic survey. The OEE #1 well was drilled in 2022 and acquired extensive core, log, and testing data to characterize the subsurface geology of the site. Coring was focused on the storage interval, the Mt. Simon Sandstone, and the confining interval, the Eau Claire Formation. The core and log data were used to evaluate the sedimentology and sequence stratigraphy, as well as to develop the conceptual geologic model. This report includes the geological summaries of the Mt. Simon Sandstone and the Eau Claire Formation. The extensive analysis of the log data is included in the petrophysical section, showing ranges of porosity, estimated pore size, and the mineral content of selected zones in the well. The separate petrographic technical report entitled “Petrographic and Advanced Geologic Characterization Report on One Earth Energy #1 (API# 1211325373)”, report number DOE-UIUC-0031892-04, details thin section point-counting analysis that includes mineralogical and pore space analysis, including grain size analysis, annotated thin section photomicrographs, scanning electron microscopy (SEM) with energy dispersive X-ray spectroscopy (EDS), and statistics of grain size analysis on Mt. Simon thin sections from OEE #1. The final OEE #1 well data to be included in this geology report is the routine core analysis of both whole core plugs and rotary sidewall core plugs. In addition to the OEE #1 well, four 2D seismic lines and a small 3D survey were acquired as part of the overall subsurface geological characterization. This geology report references the seismic interpretation report, entitled “One Earth Energy Site Seismic Interpretation Task 5.0”, report number DOE-UIUC-0031892-07. This report details the stratigraphic and structural interpretation of the 2D and 3D seismic data acquired at the One Earth Energy site. The 2D seismic data was acquired in 2019 and 2021, and the 3D survey was acquired in 2022. The objectives of the seismic programs were to contribute to the subsurface characterization of the Mt. Simon-Eau Claire Storage Complex by evaluating the continuity of potential storage reservoirs and containment intervals across the project area, and to determine if any geologic features are present that would increase containment risk to the proposed carbon storage project.

09 BIOMASS FUELS↗

Parameterizing Size Distribution in Ice Clouds

PARAMETERIZING SIZE DISTRIBUTIONS IN ICE CLOUDS David L. Mitchell and Daniel H. DeSlover ABSTRACT An outstanding problem that contributes considerable uncertainty to Global Climate Model (GCM) predictions of future climate is the characterization of ice particle sizes in cirrus clouds. Recent parameterizations of ice cloud effective diameter differ by a factor of three, which, for overcast conditions, often translate to changes in outgoing longwave radiation (OLR) of 55 W m-2 or more. Much of this uncertainty in cirrus particle sizes is related to the problem of ice particle shattering during in situ sampling of the ice particle size distribution (PSD). Ice particles often shatter into many smaller ice fragments upon collision with the rim of the probe inlet tube. These small ice artifacts are counted as real ice crystals, resulting in anomalously high concentrations of small ice crystals (D < 100 µm) and underestimates of the mean and effective size of the PSD. Half of the cirrus cloud optical depth calculated from these in situ measurements can be due to this shattering phenomenon. Another challenge is the determination of ice and liquid water amounts in mixed phase clouds. Mixed phase clouds in the Arctic contain mostly liquid water, and the presence of ice is important for determining their lifecycle. Colder high clouds between -20 and -36 oC may also be mixed phase but in this case their condensate is mostly ice with low levels of liquid water. Rather than affecting their lifecycle, the presence of liquid dramatically affects the cloud optical properties, which affects cloud-climate feedback processes in GCMs. This project has made advancements in solving both of these problems. Regarding the first problem, PSD in ice clouds are uncertain due to the inability to reliably measure the concentrations of the smallest crystals (D < 100 µm), known as the “small mode”. Rather than using in situ probe measurements aboard aircraft, we employed a treatment of ice cloud optical properties formulated in terms of PSD parameters in combination with remote measurements of thermal radiances to characterize the small mode. This is possible since the absorption efficiency (Qabs) of small mode crystals is larger at 12 µm wavelength relative to 11 µm wavelength due to the process of wave resonance or photon tunneling more active at 12 µm. This makes the 12/11 µm absorption optical depth ratio (or equivalently the 12/11 µm Qabs ratio) a means for detecting the relative concentration of small ice particles in cirrus. Using this principle, this project tested and developed PSD schemes that can help characterize cirrus clouds at each of the three ARM sites: SGP, NSA and TWP. This was the main effort of this project. These PSD schemes and ice sedimentation velocities predicted from them have been used to test the new cirrus microphysics parameterization in the GCM known as the Community Climate Systems Model (CCSM) as part of an ongoing collaboration with NCAR. Regarding the second problem, we developed and did preliminary testing on a passive thermal method for retrieving the total water path (TWP) of Arctic mixed phase clouds where TWPs are often in the range of 20 to 130 g m-2 (difficult for microwave radiometers to accurately measure). We also developed a new radar method for retrieving the cloud ice water content (IWC), which can be vertically integrated to yield the ice water path (IWP). These techniques were combined to determine the IWP and liquid water path (LWP) in Arctic clouds, and hence the fraction of ice and liquid water. We have tested this approach using a case study from the ARM field campaign called M-PACE (Mixed-Phase Arctic Cloud Experiment). This research led to a new satellite remote sensing method that appears promising for detecting low levels of liquid water in high clouds typically between -20 and -36 oC. We hope to develop this method in future research.

54 ENVIRONMENTAL SCIENCES↗

A New Neutron Multiplicity Deadtime Scheme

Deadtime corrections for passive neutron coincidence counting are traditionally formulated in terms of the Totals counting rate. The deadtime correction is exponential in form with the effective deadtime being linear in terms of observed Totals rate. The deadtime coefficient for the Reals rate is traditionally fixed at four times that of the Totals rate parameter. When it comes to multiplicity counting, however, more complex expressions are typically used for the Doubles and Triples rates based on mathematical actions to the multiplicity histograms with the Singles (or Trigger) rate being treated rather simplistically. Since the Totals and Singles and Reals and Doubles, respectively, are effectively equivalent measures, the difference in deadtime treatment results is an inconsistency. Furthermore, additional empirical correction factors are often applied in the case of the multiplicity deadtime corrections and these do not follow from the underlying theoretical framework. The purpose of this paper is to re-examine the semi-empirical deadtime correction expressions from a fresh perspective. We propose to a scheme whereby Totals and Singles are treated equivalently with the correction having the transcendental form of the paralysable model. The impact of correlations on the Totals deadtime correction is shown to be modest. The deadtime correction factor for Reals and Doubles are again treated similarly also using an exponential form in terms of the corrected Total event rate but with a deadtime parameter which is not fixed ahead of time to be four times that used in the Totals correction. In the case of the Triples correction, which is evaluated from a composite expression, the deadtime corrections for the Singles and Doubles are used as appropriate but a new empirical correction, again given in terms of the corrected rate, is introduced. The new correction acts only on the part of the Triples expression which is does not represent the correlated-accidentals. The new scheme is not based on an elaborate mathematical model for deadtime losses and consequently does not involve a deadtime-function-weighted sum of histogram elements. In that sense it is simpler to understand and implement. Determination of the free deadtime parameters is based on first extracting the deadtime parameter for the Singles for which several options are available. The Doubles deadtime parameter is then based on rendering the corrected Doubles to Singles ratio for Cf-252 invariant to trigger rate. Similarly the Triple deadtime parameter is extracted from Cf-252 data given the Singles (or Trigger) and Doubles parameters. In this article we briefly review current practice, lay out the new concept and illustrate their application with experimental data of a passive neutron multiplicity counter. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗