Search NASA⌕ Search

SEARCH · Search NASA

Results for “Multiple Errors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Verification of the astrometric performance of the Korean VLBI network, using comparative SFPR studies with the VLBA AT 14/7 mm

The Korean VLBI Network (KVN) is a new millimeter VLBI dedicated array with the capability to simultaneously observe at multiple frequencies, up to 129 GHz. The innovative multi-channel receivers present significant benefits for astrometric measurements in the frequency domain. The aim of this work is to verify the astrometric performance of the KVN using a comparative study with the VLBA, a well-established instrument. For that purpose, we carried out nearly contemporaneous observations with the KVN and the VLBA, at 14/7 mm, in 2013 April. The KVN observations consisted of simultaneous dual frequency observations, while the VLBA used fast frequency switching observations. We used the Source Frequency Phase Referencing technique for the observational and analysis strategy. We find that having simultaneous observations results in superior compensation for all atmospheric terms in the observables, in addition to offering other significant benefits for astrometric analysis. We have compared the KVN astrometry measurements to those from the VLBA. We find that the structure blending effects introduce dominant systematic astrometric shifts, and these need to be taken into account. We have tested multiple analytical routes to characterize the impact of the low-resolution effects for extended sources in the astrometric measurements. The results from the analysis of the KVN and full VLBA data sets agree within 2σ of the thermal error estimate. We interpret the discrepancy as arising from the different resolutions. We find that the KVN provides astrometric results with excellent agreement, within 1σ, when compared to a VLBA configuration that has a similar resolution. Therefore, this comparative study verifies the astrometric performance of the KVN using SFPR at 14/7 mm, and validates the KVN as an astrometric instrument.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-G-TeP4-07: Automatic EPID-Based 2D Measurement of MLC Leaf Offset as a Quality Control Tool

Purpose: The MLC dosimetric leaf gap (DLG) and transmission are measured parameters which impact the dosimetric accuracy of IMRT and VMAT plans. This investigation aims to develop an efficient and accurate routine constancy check of the physical DLG in two dimensions. Methods: The manufacturer’s recommended DLG measurement method was modified by using 5 fields instead of 11 and by utilizing the Electronic Portal Imaging Device (EPID). Validations were accomplished using an ion chamber (IC) in solid water and a 2D IC array. EPID data was collected for 6 months on multiple TrueBeam linacs using both Millennium and HD MLCs at 5 different clinics in an international consortium. Matlab code was written to automatically analyze the images and calculate the 2D results. Sensitivity was investigated by introducing deliberate leaf position errors. MLC calibration and initialization history was recorded to allow quantification of their impact. Results were analyzed using statistical process control (SPC). Results: The EPID method took approximately 5 minutes. Due to detector response, the EPID measured DLG and transmission differed from the IC values but were reproducible and consistent with changes measured using the ICs. For the Millennium MLC, the EPID measured DLG and transmission were both consistently lower than IC results. The EPID method was implemented as leaf offset and transmission constancy tests (LOC and TC). Based on 6 months of measurements, the initial leaf-specific action thresholds for changes from baseline were set to 0.1 mm. Upper and lower control limits for variation were developed for each machine. Conclusion: Leaf offset and transmission constancy tests were implemented on Varian HD and Millennium MLCs using an EPID and found to be efficient and accurate. The test is effective for monitoring MLC performance using dynamic delivery and performing process control on the DLG in 2D, thus enhancing dosimetric accuracy. This work was supported by a grant from Varian Medical Systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

Benchmarking performance changes in the simulation of extratropical modes of variability across CMIP generations

In this work, we evaluate extratropical modes of variability in the three most recent phases of the Coupled Model Intercomparison Project (CMIP3, 5, and 6) to gauge improvement of climate models over time. A suite of high-level metrics is employed to objectively evaluate how well climate models simulate the qobserved Northern Annular Mode (NAM), North Atlantic Oscillation (NAO), Pacific North America pattern (PNA), Southern Annular Mode (SAM), Pacific Decadal Oscillation (PDO), North Pacific Oscillation (NPO), and North Pacific Gyre Oscillation (NPGO). We apply a Common Basis Function (CBF) approach that projects model anomalies onto observed empirical orthogonal functions (EOFs), together with the traditional EOF approach, to CMIP Historical and AMIP models. We find simulated spatial patterns of those modes have been significantly improved in the newer models, although the skill improvement is sensitive to the mode and season considered. We identify some potential contributions to the pattern improvement of certain modes (e.g., the Southern Hemisphere jet and High-top vertical coordinate), however the performance changes are likely attributed to gradual improvement of the base climate and multiple relevant processes. Less performance improvement is evident in the mode amplitude of these modes and systematic overestimation of the mode amplitude in spring remains in the newer climate models. We find that the post-dominant season amplitude errors in atmospheric modes are not limited to coupled runs but are often already evident in AMIP simulations. This suggests that rectifying the egregious post-dominant season amplitude errors found in many models can be addressed in an atmospheric-only framework making it more tractable to address in the model development process.

54 ENVIRONMENTAL SCIENCES↗

The Fast Changing Landscape of Sequencing Technologies and Their Impact on Microbial Genome Assemblies and Annotation

Background: The emergence of next generation sequencing (NGS) has provided the means for rapid and high throughput sequencing and data generation at low cost, while concomitantly creating a new set of challenges. The number of available assembled microbial genomes continues to grow rapidly and their quality reflects the quality of the sequencing technology used, but also of the analysis software employed for assembly and annotation. Methodology/Principal Findings: In this work, we have explored the quality of the microbial draft genomes across various sequencing technologies. We have compared the draft and finished assemblies of 133 microbial genomes sequenced at the Department of Energy-Joint Genome Institute and finished at the Los Alamos National Laboratory using a variety of combinations of sequencing technologies, reflecting the transition of the institute from Sanger-based sequencing platforms to NGS platforms. The quality of the public assemblies and of the associated gene annotations was evaluated using various metrics. Results obtained with the different sequencing technologies, as well as their effects on downstream processes, were analyzed. Our results demonstrate that the Illumina HiSeq 2000 sequencing system, the primary sequencing technology currently used for de novo genome sequencing and assembly at JGI, has various advantages in terms of total sequence throughput and cost, but it also introduces challenges for the downstream analyses. In all cases assembly results although on average are of high quality, need to be viewed critically and consider sources of errors in them prior to analysis. Conclusion: These data follow the evolution of microbial sequencing and downstream processing at the JGI from draft genome sequences with large gaps corresponding to missing genes of significant biological role to assemblies with multiple small gaps (Illumina) and finally to assemblies that generate almost complete genomes (Illumina+PacBio).

Mavromatis, K↗

Uncertainty about the Uncertainty [Slides]

A golden standard in science is to repeat an experiment a statistically significant number of times, recording data using the same set of detectors and the same data analysis methodology. In such case experimental error includes both the range of true values generated by repetitions of the experiment, and measurement uncertainty caused by the detector. They are independent. It is a huge and too frequently used simplification, to assume that one can measure multiple repetitions of an identical experiment, resulting in identical true experimental value. Repetitions, as similar is it is experimentally achievable result in a range of the true values rather than in a single value. When modern, very sensitive and well calibrated measurement systems are used, this range is not negligible, and sometimes dominates, in comparison to the measurement uncertainty. Range of true values depends on the physics of the experiment, while measurement uncertainty depends on the measurement method (properties of the detector not of the experiment). When data from one–of–a kind experiment are analyzed, only the measurement uncertainty is reported. It gives no information about the range, in which the true values of experiment would spread if the experiment was repeated. A frequently used approximation, that if a physical quantity is measured as a function of time, only measurement of this quantity, produces uncertainty is also in some real experiments fare to strong. Example: In reaction history time measurement uncertainty propagated to alpha dominated under certain conditions over the flux measurement uncertainty propagated to alpha. Reliability of a data point is in general independent from its measurement uncertainty. However, in practice reliable measurement methods frequently have high measurement uncertainty, while low reliability methods are applied to limit measurement uncertainty. Comparison of reliable data with high measurement uncertainty to not so reliable data measured with low uncertainty is discussed – in different scenarios different data analysis methods are applicable.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement Uncertainty in One-Of-A-Kind Event Data Analysis

A golden standard in science is to repeat an experiment a statistically significant number of times, recording data using the same set of detectors and the same data analysis methodology. In such case experimental error includes both the range of true values generated by repetitions of the experiment, and measurement uncertainty caused by the detector. They are independent. It is a huge and too frequently used simplification, to assume that one can measure multiple repetitions of an identical experiment, resulting in identical true experimental value. Repetitions, as similar is it is experimentally achievable, have unavoidable built-in differences resulting in a range of the true values rather than in a single value. When modern, very sensitive and well calibrated measurement systems are used, this range is not negligible, and sometimes dominates over the measurement uncertainty. Range of true values depends on built-in differences in physics of the experiment. Stochastic physical processes result typically in a broader range of true values than non-stochastic processes do. Measurement uncertainty depends on a measurement method (properties of the detector not of the experiment). Modern measurement methods, including digital ones, frequently make the measurement uncertainty very small. When data from one–of –a kind experiment are analyzed, only the measurement uncertainty is reported. It provides no information about the range of true experimental values, neither about reliability of a reported data point. Reliability of a data point is in general independent from its measurement uncertainty. However, in practice reliable measurement methods frequently have high measurement uncertainty, while low reliability methods are applied to limit measurement uncertainty. Comparison of reliable data with high measurement uncertainty to not so reliable data measured with low uncertainty is discussed – in different scenarios different data analysis methods are applicable. Methods for data analysis from an experiment repeated statistically significant number of times are very well developed. They do not require a detailed expertise in physics of an experiment, nor in the properties of the measurement system used, and meaning of the reported uncertainty is well understood in any scientific community. It all changes when data from one-of-a-kind experiment is analyzed. Analyst’s expertise is required both in the physics of the experiment and in all aspects of the measurement system, all possible malfunctions. Data users must remember that only measurement uncertainty is reported from any one-of-a-kind experiment. Theory with simulations may provide estimation of expected built-in differences in the experiment, and by this of expected range of true values for a given experiment; yet measurement uncertainty can never be used in place of the range of true experimental values.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Maximum theoretical angular accuracy of planar and linear arrays of sensors

The maximum theoretical accuracy in the angular location of a radiating object that can be obtained by using a planar or linear array is studied. The elements are assumed to have identical radiation patterns and the complex voltages observed at their ports are assumed to be subject to phase measurement errors, having normal probability density. An optimum scheme for the statistical extraction of the parameters defining the direction is established noting that the presence of thermal noise does not affect the structure of the estimator. Comparisons with the conventional multiple interferometric techniques are made.

Borgiotti, G. V.↗

Adaptive Quantizer for Burst Synthetic-Aperture Radar

Adaptive quantizer for burst-mode synthetic-aperture radar reduces data rate of return signal. Device, called block floating-point quantizer (BFPQ) basically analog-to-digital converter that covers wide dynamic range and discards appropriate lower order bits. BFPQ is, in effect, digital approximator with automatic gain control. Moves floatingpoint marker binary representation of signal data in accordance with perceived dynamic range. Available step sizes thus limited to multiples of underlying smallest quantization step (represented by lowest order bit). Retains only first K most significant bits of signal; (L,K) BFPQ is one that does K-bit quantization of signal originally quantized to L bits. Quantization error simply difference between actual signal level and its binary approximation. Other potential applications for BFPQ include speech compression and picture data compression.

Joo, T. H.↗

Linear and Order Statistics Combiners for Pattern Classification

Several researchers have experimentally shown that substantial improvements can be obtained in difficult pattern recognition problems by combining or integrating the outputs of multiple classifiers. This chapter provides an analytical framework to quantify the improvements in classification results due to combining. The results apply to both linear combiners and order statistics combiners. We first show that to a first order approximation, the error rate obtained over and above the Bayes error rate, is directly proportional to the variance of the actual decision boundaries around the Bayes optimum boundary. Combining classifiers in output space reduces this variance, and hence reduces the 'added' error. If N unbiased classifiers are combined by simple averaging. the added error rate can be reduced by a factor of N if the individual errors in approximating the decision boundaries are uncorrelated. Expressions are then derived for linear combiners which are biased or correlated, and the effect of output correlations on ensemble performance is quantified. For order statistics based non-linear combiners, we derive expressions that indicate how much the median, the maximum and in general the i-th order statistic can improve classifier performance. The analysis presented here facilitates the understanding of the relationships among error rates, classifier boundary distributions, and combining in output space. Experimental results on several public domain data sets are provided to illustrate the benefits of combining and to support the analytical results.

Tumer, Kagan↗

Trellis Coding of Non-coherent Multiple Symbol Full Response M-ary CPFSK with Modulation Index 1/M

This paper introduces a trellis coded modulation (TCM) scheme for non-coherent multiple full response M-ary CPFSK with modulation index 1/M. A proper branch metric for the trellis decoder is obtained by employing a simple approximation of the modified Bessel function for large signal to noise ratio (SNR). Pairwise error probability of coded sequences is evaluated by applying a linear approximation to the Rician random variable.

trellis coded modulation TCM↗

Multiple Embedded Processors for Fault-Tolerant Computing

A fault-tolerant computer architecture has been conceived in an effort to reduce vulnerability to single-event upsets (spurious bit flips caused by impingement of energetic ionizing particles or photons). As in some prior fault-tolerant architectures, the redundancy needed for fault tolerance is obtained by use of multiple processors in one computer. Unlike prior architectures, the multiple processors are embedded in a single field-programmable gate array (FPGA). What makes this new approach practical is the recent commercial availability of FPGAs that are capable of having multiple embedded processors. A working prototype (see figure) consists of two embedded IBM PowerPC 405 processor cores and a comparator built on a Xilinx Virtex-II Pro FPGA. This relatively simple instantiation of the architecture implements an error-detection scheme. A planned future version, incorporating four processors and two comparators, would correct some errors in addition to detecting them.

Bolotin, Gary↗

Analysis of a Split-Plot Experimental Design Applied to a Low-Speed Wind Tunnel Investigation

A procedure to analyze a split-plot experimental design featuring two input factors, two levels of randomization, and two error structures in a low-speed wind tunnel investigation of a small-scale model of a fighter airplane configuration is described in this report. Standard commercially-available statistical software was used to analyze the test results obtained in a randomization-restricted environment often encountered in wind tunnel testing. The input factors were differential horizontal stabilizer incidence and the angle of attack. The response variables were the aerodynamic coefficients of lift, drag, and pitching moment. Using split-plot terminology, the whole plot, or difficult-to-change, factor was the differential horizontal stabilizer incidence, and the subplot, or easy-to-change, factor was the angle of attack. The whole plot and subplot factors were both tested at three levels. Degrees of freedom for the whole plot error were provided by replication in the form of three blocks, or replicates, which were intended to simulate three consecutive days of wind tunnel facility operation. The analysis was conducted in three stages, which yielded the estimated mean squares, multiple regression function coefficients, and corresponding tests of significance for all individual terms at the whole plot and subplot levels for the three aerodynamic response variables. The estimated regression functions included main effects and two-factor interaction for the lift coefficient, main effects, two-factor interaction, and quadratic effects for the drag coefficient, and only main effects for the pitching moment coefficient.

Erickson, Gary E.↗

Towards Understanding Data Requirements for Developing Automatic Speech Recognition Systems for Air Traffic Control

In recent years, the application of automatic speech recognition has gained popularity across diverse industries, including aviation. Given the many applications focusing on transcribing air traffic control and management communication, this paper explores the training of OpenAI's Whisper model across multiple existing public and private air traffic control voice datasets in an effort to improve robustness. Combining roughly 60+ hours of various air traffic datasets, our goal is to train a unified Whisper model and expect an average word error rate reduction across testing datasets. Furthermore, this work aims to understand the data quantity requirements for achieving state-of-the art results by comprehensively training Whisper on varying dataset sizes. This work has the potential to improve automatic speech recognition performance across the domain, improve understanding of the quantity of data required by an aviation speech recognition system, and lastly provide metrics to compare and improve upon in future research.

ATC↗

Flux stabilization in neutron problems with fixed sources

Although critical core calculations are the most common in design and safety analysis, fixed source calculations are needed for specific applications, e.g. to compute ex-core detector response functions, to develop new methodologies for dilution and reload error accidents and more in general for all situations involving sub-critical shut-down states. It is well known that the source problem becomes difficult to be solved with core configuration close to criticality, i.e. with the multiplication factor approaching unity, for the occurrence of numerical ill-conditioning and very high number of iterations, possibly leading to failure in the flux convergence. In this work, the Wielandt Eigen-shift technique used in iterative methods of critical problems is developed for source problems too, in order to stabilize the solution. The mathematical basis and the proof of the convergence are discussed. Compared to the existing methods, this technique allows also more control to avoid singular behavior at inner iterations. Numerical tests with a 1D analytical benchmark are reported to prove the robustness of the technique. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Heel effect adaptive flat field correction of digital x-ray detectors

Purpose: Anode heel effect renders large-scale background nonuniformities in digital radiographs. Conventional offset/gain calibration is performed at mono source-to-image distance (SID), and disregards the SID-dependent characteristic of heel effect. It results in a residual nonuniform background in the corrected radiographs when the SID settings for calibration and correction differ. In this work, the authors develop a robust and efficient computational method for digital x-ray detector gain correction adapted to SID-variant heel effect, without resorting to physical filters, phantoms, complicated heel effect models, or multiple-SID calibration and interpolation.Methods: The authors present the Duo-SID projection correction method. In our approach, conventional offset/gain calibrations are performed only twice, at the minimum and maximum SIDs of the system in typical clinical use. A fast iterative separation algorithm is devised to extract the detector gain and basis heel patterns from the min/max SID calibrations. The resultant detector gain is independent of SID, while the basis heel patterns are parameterized by the min- and max-SID. The heel pattern at any SID is obtained from the min-SID basis heel pattern via projection imaging principles. The system gain desired at a specific acquisition SID is then constructed using the projected heel pattern and detector gain map.Results: The method was evaluated for flat field and anatomical phantom image corrections. It demonstrated promising improvements over interpolation and conventional gain calibration/correction methods, lowering their correction errors by approximately 70% and 80%, respectively. The separation algorithm was able to extract the detector gain and heel patterns with less than 2% error, and the Duo-SID corrected images showed perceptually appealing uniform background across the detector.Conclusions: The Duo-SID correction method has substantially improved on conventional offset/gain corrections for digital x-ray imaging in an SID-variant environment. The technique is relatively simple, and can be easily incorporated into multiple-point gain calibration/correction techniques. It offers a potentially valuable tool for preprocessing digital x-ray images to boost image quality of mammography, chest and cardiac radiography, as well as automated computer aided diagnostic radiology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Performance Bounds on Two Concatenated, Interleaved Codes

A method has been developed of computing bounds on the performance of a code comprised of two linear binary codes generated by two encoders serially concatenated through an interleaver. Originally intended for use in evaluating the performances of some codes proposed for deep-space communication links, the method can also be used in evaluating the performances of short-block-length codes in other applications. The method applies, more specifically, to a communication system in which following processes take place: At the transmitter, the original binary information that one seeks to transmit is first processed by an encoder into an outer code (Co) characterized by, among other things, a pair of numbers (n,k), where n (n > k)is the total number of code bits associated with k information bits and n k bits are used for correcting or at least detecting errors. Next, the outer code is processed through either a block or a convolutional interleaver. In the block interleaver, the words of the outer code are processed in blocks of I words. In the convolutional interleaver, the interleaving operation is performed bit-wise in N rows with delays that are multiples of B bits. The output of the interleaver is processed through a second encoder to obtain an inner code (Ci) characterized by (ni,ki). The output of the inner code is transmitted over an additive-white-Gaussian- noise channel characterized by a symbol signal-to-noise ratio (SNR) Es/No and a bit SNR Eb/No. At the receiver, an inner decoder generates estimates of bits. Depending on whether a block or a convolutional interleaver is used at the transmitter, the sequence of estimated bits is processed through a block or a convolutional de-interleaver, respectively, to obtain estimates of code words. Then the estimates of the code words are processed through an outer decoder, which generates estimates of the original information along with flags indicating which estimates are presumed to be correct and which are found to be erroneous. From the perspective of the present method, the topic of major interest is the performance of the communication system as quantified in the word-error rate and the undetected-error rate as functions of the SNRs and the total latency of the interleaver and inner code. The method is embodied in equations that describe bounds on these functions. Throughout the derivation of the equations that embody the method, it is assumed that the decoder for the outer code corrects any error pattern of t or fewer errors, detects any error pattern of s or fewer errors, may detect some error patterns of more than s errors, and does not correct any patterns of more than t errors. Because a mathematically complete description of the equations that embody the method and of the derivation of the equations would greatly exceed the space available for this article, it must suffice to summarize by reporting that the derivation includes consideration of several complex issues, including relationships between latency and memory requirements for block and convolutional codes, burst error statistics, enumeration of error-event intersections, and effects of different interleaving depths. In a demonstration, the method was used to calculate bounds on the performances of several communication systems, each based on serial concatenation of a (63,56) expurgated Hamming code with a convolutional inner code through a convolutional interleaver. The bounds calculated by use of the method were compared with results of numerical simulations of performances of the systems to show the regions where the bounds are tight (see figure).

Moision, Bruce↗

Multiple Cases of Bacterial Sequence Erroneously Incorporated Into Publicly Available Chloroplast Genomes

Public sequencing databases are invaluable resources to biological researchers, but assessing data veracity as well as the curation and maintenance of such large collections of data can be challenging. Genomes of eukaryotic organelles, such as chloroplasts and other plastids, are particularly susceptible to assembly errors and misrepresentations in these databases due to their close evolutionary relationships with bacteria, which may co-occur within the same environment, as can be the case when sequencing plants. Here, based on sequence similarities with bacterial genomes, we identified several suspicious chloroplast assemblies present in the National Institutes of Health (NIH) Reference Sequence (RefSeq) collection. Investigations into these chloroplast assemblies reveal examples of erroneous integration of bacterial sequences into chloroplast ribosomal RNA (rRNA) loci, often within the rRNA genes, presumably due to the high similarity between plastid and bacterial rRNAs. The bacterial lineages identified within the examined chloroplasts as the most likely source of contamination are either known associates of plants, or co-occur in the same environmental niches as the examined plants. Modifications to the methods used to process untargeted ‘raw’ shotgun sequencing data from whole genome sequencing efforts, such as the identification and removal of bacterial reads prior to plastome assembly, could eliminate similar errors in the future.

59 BASIC BIOLOGICAL SCIENCES↗

Multiple feedback control apparatus for power conditioning equipment

An improved feedback control system to govern the cyclic operation of the power switch of a non-dissipative power conditioning equipment. The apparatus includes two or three control loops working in unison. The first causes the output DC level to be compared with a reference, and the error amplified for control purposes. The second utilizes the AC component of the voltage across the output filter inductor or the current through the output filter capacitor, and the third loop senses the output transients.

Biess, John↗