Search NASA⌕ Search

SEARCH · Search NASA

Results for “Normalization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Plate motion in sheared granular fault system

Plate motion near the fault gouge layer, and the elastic interplay between the gouge layer and the plate under stick-slip conditions, is key to understanding the dynamics of sheared granular fault systems. Here, a two-dimensional implementation of the combined finite-discrete element method (FDEM), which merges the finite element method (FEM) and the discrete element method (DEM), is used to explicitly simulate a sheared granular gouge fault system. In this work we focus on investigating the influence of normal load, driving shear velocity and plate stiffness on the velocities and displacements in the direction parallel to the shear direction (x-direction) measured at locations on the upper and lower plates just adjacent to the gouge. The simulations show that during slip phases the magnitudes of the measured velocities on the upper and lower plates are proportional to the normal load and may be inversely proportional to the square root of the plate's shear modulus. Whereas, the driving shear velocity does not show distinct influence on the measured velocities. Additionally, large slip velocities are generally associated with large macroscopic friction coefficient drops. For the models subjected to smaller normal loads, larger shear velocities and with stiffer shear plates, the same magnitude of slip velocity could cause a larger drop of macroscopic friction coefficient. During stick phases, the velocities of the upper and lower plates are respectively slightly greater and slightly smaller than half of the driving shear velocity and are both in the same direction of shear. The shear strain rate of the gouge is calculated from this velocity difference between the upper and lower plate during stick phases and thus the gouge effective shear modulus can be calculated. The results show that the gouge effective shear modulus increases proportionally with normal load, while the influence of shear velocity and plate stiffness on gouge effective shear modulus is minor. The simulations address the dynamics of a laboratory-scale fault gouge system and may aid in revealing the complexities of earthquake frictional dynamics.

58 GEOSCIENCES↗

Forced and mixed convection heat transfer to supercritical CO{sub 2} vertically flowing in a uniformly-heated circular tube

An experiment of heat transfer to CO{sub 2}, which flows upward and downward in a circular tube with an inner diameter of 6.32 mm, was carried out with mass flux of 285-1200 kg/m{sup 2} s and heat flux of 30-170 kW/m{sup 2} at pressures of 7.75 and 8.12 MPa, respectively. The corresponding Reynolds number at the tube test section inlet ranges from 1.8 x 10{sup 4} to 3.8 x 10{sup 5}. The tube inner diameter corresponds to the equivalent hydraulic diameter of the fuel assembly sub-channel, which is being studied at KAERI. Among the tested correlations, the Bishop correlation predicted the experimental data most accurately, but only 66.9% of normal heat transfer data were predicted within {+-}30% error range. The Watts and Chou correlation, which is claimed to be valid for both the normal and deteriorated heat transfer regime, showed unsatisfactory performance. A significant decrease in Nusselt number was observed in the range of 10{sup -6}<Gr{sub b}/Re{sub b}{sup 2.7}<2 x 10{sup -5} before entering a serious heat transfer deterioration regime. The heat transfer deteriorated when the value of the buoyancy parameter Gr{sub b}/Re{sub b}{sup 2.7} exceeded 2.0 x 10{sup -5} close to the Jackson and Hall's criterion. As soon as the heat transfer deteriorated, it entered a new regime and did not return to a normal heat transfer regime, although the value of buoyancy parameter Gr{sub b}/Re{sub b}{sup 2.7} reduced below the deterioration criterion 2.0 x 10{sup -5}. It may justify the requirement of developing separate correlations for the normal and deterioration regimes, as proposed in this paper. (author)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A direct numerical simulation study for confined non-isothermal jet impingement at moderate nozzle-to-plate distances: Capturing jet-to-ambient density effects

A direct numerical simulation (DNS) campaign is deployed for a series of confined downward oriented, non-isothermal turbulent impinging jet configurations. A baseline Reynolds number of 9960 is obtained through a precursor DNS pipe flow simulation (Re τ = 505). Three jet temperature configurations (confinement height to nozzle diameter of three) enter a cylindrical domain that share ambient and impingement plate temperatures (298.15 K). The range of jet temperatures are crafted such that the ratio of inlet to ambient density varies from unity to 0.52, showcasing the effect of density disparity on flow characteristics such as core collapse, radial mixing of momentum and energy, near-wall stagnation behavior, wall-jet profiles, and large-scale vortical structures. Surface quantities provided include mean radial heat flux and wall-shear stress profiles, and heat flux histograms at select radial stations. Results showcase increased radial normal stresses for higher temperature jets that support increased mixing, resulting in large-scale recirculation structures that are smaller, while retaining similar normalized radial wall profiles for shear stress, heat flux and pressure. Furthermore, radial plots for wall shear stress and Nusselt number showcase strong radial decay as compared to previous configurations that share similar jet and ambient temperatures. For the 373.15 K case, a Gaussian-like histogram for heat fluxes at the impingement plate transitions to a log-normal profile as radial distances increase. In contrast, the 573.15 K configuration displays a bi-modal heat flux characteristic at the impingement plate, and in similar manner to the moderate temperature counterpart, transitions to a log-normal profile at larger radial distances.

33 ADVANCED PROPULSION SYSTEMS↗

Dynamic Crush Behaviors Of Aluminum Honeycomb Specimens Under Compression Dominant Inclined Loads

The quasi-static and dynamic crush behaviors of aluminum 5052-H38 honeycomb specimens under out-of-plane inclined loads are investigated by experiments. Different types of honeycomb specimens were designed for crush tests under pure compressive and inclined loads with respect to the out-of-plane direction. A test fixture was designed for both quasi-static and dynamic crush tests under inclined loads. The results of the quasi-static crush tests indicate that the normal crush and shear strengths under inclined loads are consistent with the corresponding results under combined loads. The results of the dynamic crush tests indicate that as the impact velocity increases, the normal crush strength increases and the shear strength remains nearly the same. The trends of the normalized normal crush strengths under inclined loads for specimens with different in-plane orientation angles as functions of the impact velocity are very similar to each other. Based on the experimental results, a macroscopic yield criterion as a function of the impact velocity is proposed. The experimental results suggest that as the impact velocity increases, the shape of the macroscopic yield surface changes, or more specifically, the curvature of the yield surface increases near the pure compression state. The experimental results also show similar microscopic progressive folding mechanisms in honeycomb specimens under pure compressive and inclined loads. However, honeycomb specimens under inclined loads show inclined stacking patterns of folds due to the asymmetric location of horizontal plastic hinge lines.

36 MATERIALS SCIENCE↗

Reirradiation Tolerance of the Human Brain

Purpose: To give an overview of current available clinical data on reirradiation of glioma with respect to the tolerance dose of normal brain tissue. Methods and Materials: Clinical brain reirradiation studies from January 1996 to December 2006 were considered on radiation-induced late adverse effects-i.e., brain tissue necrosis. The studies were analyzed by using the linear quadratic model to derive information on the cumulative biologic effective tolerance dose and equivalent doses in 2-Gy fractions for the healthy human brain. Results: The cumulative dose in conventional reirradiation series (of 81.6-101.9 Gy) were generally lower than in fractionated stereotactic radiotherapy (FSRT) ( 90-133.9 Gy.) or LINAC-based stereotactic radiosurgery series (of 111.6-137.2 Gy). No correlation between the time interval between the initial and reirradiation course and the incidence of radionecrosis was noted. The analysis showed the prescribed to increase with decreasing treatment volume, which is allowed by modern conformal radiation techniques. Conclusion: Radiation-induced normal brain tissue necrosis is found to occur at >100 Gy. The applied reirradiation dose and increases with a change in irradiation technique from conventional to radiosurgery re-treatment, without increasing the probability of normal brain necrosis. Taken together, modern conformal treatment options, because of their limited volume of normal brain tissue exposure, allow brain reirradiation for palliative treatment of recurrent high grade glioma with an acceptable probability of radionecrosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Rigid and Adaptive Methods of Propagating Gross Tumor Volume Through Respiratory Phases of Four-Dimensional Computed Tomography Image Data Set

Purpose: To compare three different methods of propagating the gross tumor volume (GTV) through the respiratory phases that constitute a four-dimensional computed tomography image data set. Methods and Materials: Four-dimensional computed tomography data sets of 20 patients who had undergone definitive hypofractionated radiotherapy to the lung were acquired. The GTV regions of interest (ROIs) were manually delineated on each phase of the four-dimensional computed tomography data set. The ROI from the end-expiration phase was propagated to the remaining nine phases of respiration using the following three techniques: (1) rigid-image registration using in-house software, (2) rigid image registration using research software from a commercial radiotherapy planning system vendor, and (3) rigid-image registration followed by deformable adaptation originally intended for organ-at-risk delineation using the same software. The internal GTVs generated from the various propagation methods were compared with the manual internal GTV using the normalized Dice similarity coefficient (DSC) index. Results: The normalized DSC index of 1.01 {+-} 0.06 (SD) for rigid propagation using the in-house software program was identical to the normalized DSC index of 1.01 {+-} 0.06 for rigid propagation achieved with the vendor's research software. Adaptive propagation yielded poorer results, with a normalized DSC index of 0.89 {+-} 0.10 (paired t test, p <0.001). Conclusion: Propagation of the GTV ROIs through the respiratory phases using rigid- body registration is an acceptable method within a 1-mm margin of uncertainty. The adaptive organ-at-risk propagation method was not applicable to propagating GTV ROIs, resulting in an unacceptable reduction of the volume and distortion of the ROIs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment Planning Study to Determine Potential Benefit of Intensity-Modulated Radiotherapy Versus Conformal Radiotherapy for Unresectable Hepatic Malignancies

Purpose: To compare intensity-modulated radiotherapy (IMRT) with conformal RT (CRT) for hypofractionated isotoxicity liver RT and explore dose escalation using IMRT for the same/improved nominal risk of liver toxicity in a treatment planning study. Methods and Materials: A total of 26 CRT plans were evaluated. Prescription doses (24-54 Gy within six fractions) were individualized on the basis of the effective liver volume irradiated maintaining {<=}5% risk of radiation-induced liver disease. The dose constraints included bowel (0.5 cm{sup 3}) and stomach (0.5 cm{sup 3}) to {<=}30 Gy, spinal cord to {<=}25 Gy, and planning target volume (PTV) to {<=}140% of the prescribed dose. Two groups were evaluated: (1) PTV overlapping or directly adjacent to serial functioning normal tissues (n = 14), and (2) the liver as the dose-limiting normal tissue (n = 12). IMRT plans using direct machine parameter optimization maintained the CRT plan beam arrangements, an estimated radiation-induced liver disease risk of 5%, and underwent dose escalation, if all normal tissue constraints were maintained. Results: IMRT improved PTV coverage in 19 of 26 plans (73%). Dose escalation was feasible in 9 cases by an average of 3.8 Gy (range, 0.6-13.2) in six fractions. Three of seven plans without improved PTV coverage had small gross tumor volumes ({<=}105 cm{sup 3}) already receiving 54 Gy, the maximal prescription dose allowed. In the remaining cases, the PTV range was 9.6-689 cm{sup 3}; two had overlapped organs at risk; and one had four targets. IMRT did not improve these plans owing to poor target coverage (n = 2) and nonliver (n = 2) dose limits. Conclusion: Direct machine parameter optimization IMRT improved PTV coverage while maintaining normal tissue tolerances in most CRT liver plans. Dose escalation was possible in a minority of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Respiratory Organ Motion and Dosimetric Impact on Breast and Nodal Irradiation

Purpose: To examine the respiratory motion for target and normal structures during whole breast and nodal irradiation and the resulting dosimetric impact. Methods and Materials: Four-dimensional CT data sets of 18 patients with early-stage breast cancer were analyzed retrospectively. A three-dimensional conformal dosimetric plan designed to irradiate the breast was generated on the basis of CT images at 20% respiratory phase (reference phase). The reference plans were copied to other respiratory phases at 0% (end of inspiration) and 50% (end of expiration) to simulate the effects of breathing motion on whole breast irradiation. Dose-volume histograms, equivalent uniform dose, and normal tissue complication probability were evaluated and compared. Results: Organ motion of up to 8.8 mm was observed during free breathing. A large lung centroid movement was typically associated with a large shift of other organs. The variation of planning target volume coverage during a free breathing cycle is generally within 1%-5% (17 of 18 patients) compared with the reference plan. However, up to 28% of V{sub 45} variation for the internal mammary nodes was observed. Interphase mean dose variations of 2.2%, 1.2%, and 1.4% were observed for planning target volume, ipsilateral lung, and heart, respectively. Dose variations for the axillary nodes and brachial plexus were minimal. Conclusions: The doses delivered to the target and normal structures are different from the planned dose based on the reference phase. During normal breathing, the dosimetric impact of respiratory motion is clinically insignificant with the exception of internal mammary nodes. However, noticeable degradation in dosimetric plan quality may be expected for the patients with large respiratory motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Impact of Online Correction via Cone-Beam CT-Based Image Guidance for Stereotactic Lung Radiotherapy

Purpose: To evaluate the dosimetric impact of online cone-beam computed tomography (CBCT) guided correction in lung stereotactic body radiation therapy (SBRT). Methods and Materials: Twenty planning and 162 CBCT images from 20 patients undergoing lung SBRT were analyzed. The precorrection CBCT (CBCT after patient setup, no couch correction) was registered to planning CT using soft tissue; couch shift was applied, with a second CBCT for verification (postcorrection CBCT). Targets and normal structures were delineated on CBCTs: gross tumor volume (GTV), clinical target volume (CTV), cord, esophagus, lung, proximal bronchial tree, and aorta. Dose distributions on all organs manifested on each CBCT were compared with those planned on the CT. Results: Without CBCT guided target position correction, target dose reduced with respect to treatment plan. Mean and standard deviation of treatment dose discrepancy from the plan were -3.2% (4.9%), -2.1% (4.4%), -6.1% (10.7%), and -3.5% (7%) for GTV D{sub 99%}, GTV D{sub 95%}, CTV D{sub 99%}, and CTV D{sub 95%}, respectively. With CBCT correction, the results were -0.4% (2.6%), 0.1% (1.7%), -0.3% (4.2%), and 0.5% (3%). Mean and standard deviation of the difference in normal organ maximum dose were 2.2% (6.5%) before correction and 2.4% (5.9%) after correction for esophagus; 6.1% (14.1%) and 3.8% (8.1%) for cord; 3.1% (17.5%) and 6.2% (9.8%) for proximal bronchial tree; and 17.7% (19.5%) and 14.1% (17%) for aorta. Conclusion: Online CBCT guidance improves the accuracy of target dose delivery for lung SBRT. However, treatment dose to normal tissue can vary regardless of the correction. Normal tissues should be considered during target registration, according to target proximity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Effect of Breathing Motion on Radiotherapy Dose Accumulation in the Abdomen Using Deformable Registration

Purpose: To investigate the effect of breathing motion and dose accumulation on the planned radiotherapy dose to liver tumors and normal tissues using deformable image registration. Methods and Materials: Twenty-one free-breathing stereotactic liver cancer radiotherapy patients, planned on static exhale computed tomography (CT) for 27-60 Gy in six fractions, were included. A biomechanical model-based deformable image registration algorithm retrospectively deformed each exhale CT to inhale CT. This deformation map was combined with exhale and inhale dose grids from the treatment planning system to accumulate dose over the breathing cycle. Accumulation was also investigated using a simple rigid liver-to-liver registration. Changes to tumor and normal tissue dose were quantified. Results: Relative to static plans, mean dose change (range) after deformable dose accumulation (as % of prescription dose) was -1 (-14 to 8) to minimum tumor, -4 (-15 to 0) to maximum bowel, -4 (-25 to 1) to maximum duodenum, 2 (-1 to 9) to maximum esophagus, -2 (-13 to 4) to maximum stomach, 0 (-3 to 4) to mean liver, and -1 (-5 to 1) and -2 (-7 to 1) to mean left and right kidneys. Compared to deformable registration, rigid modeling had changes up to 8% to minimum tumor and 7% to maximum normal tissues. Conclusion: Deformable registration and dose accumulation revealed potentially significant dose changes to either a tumor or normal tissue in the majority of cases as a result of breathing motion. These changes may not be accurately accounted for with rigid motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preferential Effect of Synchrotron Microbeam Radiation Therapy on Intracerebral 9L Gliosarcoma Vascular Networks

Purpose: Synchrotron microbeam radiation therapy (MRT) relies on spatial fractionation of the incident photon beam into parallel micron-wide beams. Our aim was to analyze the effects of MRT on normal brain and 9L gliosarcoma tissues, particularly on blood vessels. Methods and Materials: Responses to MRT (two arrays, one lateral, one anteroposterior (2 x 400 Gy), intersecting orthogonally in the tumor region) were studied during 6 weeks using MRI, immunohistochemistry, and vascular endothelial growth factor Western blot. Results: MRT increased the median survival time of irradiated rats (x3.25), significantly increased blood vessel permeability, and inhibited tumor growth; a cytotoxic effect on 9L cells was detected 5 days after irradiation. Significant decreases in tumoral blood volume fraction and vessel diameter were measured from 8 days after irradiation, due to loss of endothelial cells in tumors as detected by immunochemistry. Edema was observed in the normal brain exposed to both crossfired arrays about 6 weeks after irradiation. This edema was associated with changes in blood vessel morphology and an overexpression of vascular endothelial growth factor. Conversely, vascular parameters and vessel morphology in brain regions exposed to one of the two arrays were not damaged, and there was no loss of vascular endothelia. Conclusions: We show for the first time that preferential damage of MRT to tumor vessels versus preservation of radioresistant normal brain vessels contributes to the efficient palliation of 9L gliosarcomas in rats. Molecular pathways of repair mechanisms in normal and tumoral vascular networks after MRT may be essential for the improvement of such differential effects on the vasculature.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Online Adaptive Radiotherapy for Muscle-Invasive Bladder Cancer: Results of a Pilot Study

Purpose: To determine the advantages and disadvantages of daily online adaptive image-guided radiotherapy (RT) compared with conventional RT for muscle-invasive bladder cancer. Methods and Materials: Twenty-seven patients with T2-T4 transitional cell carcinoma of the bladder were treated with daily online adaptive image-guided RT using cone-beam computed tomography (CBCT). From day 1 daily soft tissue-based isocenter positioning was performed using CBCT images acquired before treatment. Using a composite of the initial planning CT and the first five daily CBCT scans, small, medium, and large adaptive plans were created. Each of these adaptive plans used a 0.5-cm clinical target volume (CTV) to planning target volume expansion. For Fractions 8-32, treatment involved daily soft tissue-based isocenter positioning and selection of suitable adaptive plan of the day. Treating radiation therapists completed a credentialing program, and one radiation oncologist performed all the contouring. Comparisons were made between adaptive and conventional treatment on the basis of CTV coverage and normal tissue sparing. Results: All 27 patients completed treatment per protocol. Bladder volume decreased with time or fraction number (p < 0.0001). For the adaptive component (Fractions 8-32) the small, medium, large, and conventional plans were used in 9.8%, 49.2%, 39.5%, and 1.5% of fractions, respectively. For the adaptive strategy, 2.7% of occasions resulted in a CTV V95 <99%, compared with 4.8% of occasions for the conventional approach (p = 0.42). Mean volume of normal tissue receiving a dose >45 Gy was 29% (95% confidence interval, 24-35%) less with adaptive RT compared with conventional RT. The mean volume of normal tissue receiving >5 Gy was 15% (95% confidence interval, 11-18%) less with adaptive RT compared with conventional RT. Conclusions: Online adaptive radiotherapy is feasible in an academic radiotherapy center. The volume of normal tissue irradiated can be significantly smaller without reducing CTV coverage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

On the Benefits and Risks of Proton Therapy in Pediatric Craniopharyngioma

Purpose: Craniopharyngioma is a pediatric brain tumor whose volume is prone to change during radiation therapy. We compared photon- and proton-based irradiation methods to determine the effect of tumor volume change on target coverage and normal tissue irradiation in these patients. Methods and Materials: For this retrospective study, we acquired imaging and treatment-planning data from 14 children with craniopharyngioma (mean age, 5.1 years) irradiated with photons (54 Gy) and monitored by weekly magnetic resonance imaging (MRI) examinations during radiation therapy. Photon intensity-modulated radiation therapy (IMRT), double-scatter proton (DSP) therapy, and intensity-modulated proton therapy (IMPT) plans were created for each patient based on his or her pre-irradiation MRI. Target volumes were contoured on each weekly MRI scan for adaptive modeling. The measured differences in conformity index (CI) and normal tissue doses, including functional sub-volumes of the brain, were compared across the planning methods, as was target coverage based on changes in target volumes during treatment. Results: CI and normal tissue dose values of IMPT plans were significantly better than those of the IMRT and DSP plans (p < 0.01). Although IMRT plans had a higher CI and lower optic nerve doses (p < 0.01) than did DSP plans, DSP plans had lower cochlear, optic chiasm, brain, and scanned body doses (p < 0.01). The mean planning target volume (PTV) at baseline was 54.8 cm{sup 3}, and the mean increase in PTV was 11.3% over the course of treatment. The dose to 95% of the PTV was correlated with a change in the PTV; the R{sup 2} values for all models, 0.73 (IMRT), 0.38 (DSP), and 0.62 (IMPT), were significant (p < 0.01). Conclusions: Compared with photon IMRT, proton therapy has the potential to significantly reduce whole-brain and -body irradiation in pediatric patients with craniopharyngioma. IMPT is the most conformal method and spares the most normal tissue; however, it is highly sensitive to target volume changes, whereas the DSP method is not.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimized Planning Target Volume for Intact Cervical Cancer

Purpose: To model interfraction clinical target volume (CTV) variation in patients with intact cervical cancer and design a planning target volume (PTV) that minimizes normal tissue dose while maximizing CTV coverage. Methods and Materials: We analyzed 50 patients undergoing external-beam radiotherapy for intact cervical cancer using daily online cone-beam computed tomography (CBCT). The CBCTs (n = 972) for each patient were rigidly registered to the planning CT. The CTV was delineated on the planning CT (CTV{sub 0}) and the set of CBCTs ({l_brace}CTV{sub 1}-CTV{sub 25}{r_brace}). Manual (n = 98) and automated (n = 668) landmarks were placed over the surface of CTV{sub 0} with reference to defined anatomic structures. Normal vectors were extended from each landmark, and the minimum length required for a given probability of encompassing CTV{sub 1}-CTV{sub 25} was computed. The resulting expansions were used to generate an optimized PTV. Results: The mean (SD; range) normal vector length to ensure 95% coverage was 4.3 mm (2.7 mm; 1-16 mm). The uniform expansion required to ensure 95% probability of CTV coverage was 13 mm. An anisotropic margin of 20 mm anteriorly and posteriorly and 10 mm superiorly, inferiorly, and laterally also would have ensured a 95% probability of CTV coverage. The volume of the 95% optimized PTV (1470 cm{sup 3}) was significantly lower than both the anisotropic PTV (2220 cm{sup 3}) and the uniformly expanded PTV (2110 cm{sup 3}) (p < 0.001). For a 95% probability of CTV coverage, normal lengths of 1-3 mm were found along the superior and lateral regions of CTV{sub 0}, 5-10 mm along the interfaces of CTV{sub 0} with the bladder and rectum, and 10-14 mm along the anterior surface of CTV{sub 0} at the level of the uterus. Conclusion: Optimizing PTV definition according to surface landmarking resulted in a high probability of CTV coverage with reduced PTV volumes. Our results provide data justifying planning margins to use in practice and clinical trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Tumor Shape Variability in Head-and-Neck Cancer Patients Over the Course of Radiation Therapy Using Implanted Gold Markers

Purpose: This study quantifies tumor shape variability in head-and-neck cancer patients during radiation therapy using implanted markers. Methods and Materials: Twenty-seven patients with oropharyngeal tumors treated with (chemo)radiation were included. Helical gold markers (0.35 Multiplication-Sign 2 mm, 3-10/patient, average 6) were implanted around the tumor. Markers were identified on planning computed tomography (CT) and daily cone beam CT (CBCT). After bony anatomy registration, the daily vector length on CBCT in reference to the planning CT and daily marker movement perpendicular to the gross tumor volume (GTV) surface at planning CT (d{sub normal}) of each marker were analyzed. Time trends were assessed with linear regression of the {sub markers}. In 2 patients, 2 markers were implanted in normal tissue to evaluate migration by measuring intermarker distances. Results: Marker implantation was feasible without complications. Three-dimensional vectors (4827 measurements, mean 0.23 cm, interquartile ratio 0.24 cm) were highest in base of tongue sublocalization (P<.001) and bulky tumors (vectors exceeded 0.5 cm in 5.7% [0-20 mL], 12.0% [21-40 mL], and 21.7% [{>=}41 mL], respectively [P<.001] of measurements). The measured inward time trend in 11/27 patients correlated with the visual observed marker pattern. In patients with an outward trend (5/27) or no trend (11/27), visual observation showed predominantly an inhomogeneous pattern. Remarkably, in 6 patients, outward marker movement was observed in the posterior pharyngeal wall. The difference in distance between normal tissue markers (1 SD) was 0.05-0.06 cm without time trend, indicating that implanted markers did not migrate. Conclusions: During head-and-neck radiation therapy, normal tissue markers remained stable. Changes in position of tumor markers depended on sublocalization and tumor volume. Large differences in marker patterns between patients as well as within patients were observed. Based on our study, the cranial and caudal border in the posterior pharyngeal wall are at highest risk to be covered insufficiently. Furthermore, implanted markers could help identify patients with an actual shrinkage of the GTV who might benefit from mid-radiation therapy redelineation to reduce toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anisotropic Margin Expansions in 6 Anatomic Directions for Oropharyngeal Image Guided Radiation Therapy

Purpose: The purpose of this work was to determine the expansions in 6 anatomic directions that produced optimal margins considering nonrigid setup errors and tissue deformation for patients receiving image-guided radiation therapy (IGRT) of the oropharynx. Methods and Materials: For 20 patients who had received IGRT to the head and neck, we deformably registered each patient's daily images acquired with a computed tomography (CT)-on-rails system to his or her planning CT. By use of the resulting vector fields, the positions of volume elements within the clinical target volume (CTV) (target voxels) or within a 1-cm shell surrounding the CTV (normal tissue voxels) on the planning CT were identified on each daily CT. We generated a total of 15,625 margins by dilating the CTV by 1, 2, 3, 4, or 5 mm in the posterior, anterior, lateral, medial, inferior, and superior directions. The optimal margins were those that minimized the relative volume of normal tissue voxels positioned within the margin while satisfying 1 of 4 geometric target coverage criteria and 1 of 3 population criteria. Results: Each pair of geometric target coverage and population criteria resulted in a unique, anisotropic, optimal margin. The optimal margin expansions ranged in magnitude from 1 to 5 mm depending on the anatomic direction of the expansion and on the geometric target coverage and population criteria. Typically, the expansions were largest in the medial direction, were smallest in the lateral direction, and increased with the demand of the criteria. The anisotropic margin resulting from the optimal set of expansions always included less normal tissue than did any isotropic margin that satisfied the same pair of criteria. Conclusions: We demonstrated the potential of anisotropic margins to reduce normal tissue exposure without compromising target coverage in IGRT to the head and neck.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Coniferyl Aldehyde Reduces Radiation Damage Through Increased Protein Stability of Heat Shock Transcriptional Factor 1 by Phosphorylation

Purpose: We previously screened natural compounds and found that coniferyl aldehyde (CA) was identified as an inducer of HSF1. In this study, we further examined the protective effects of CA against ionizing radiation (IR) in normal cell system. Methods and Materials: Western blotting and reverse transcription-polymerase chain reaction tests were performed to evaluate expression of HSF1, HSP27, and HSP70 in response to CA. Cell death and cleavage of PARP and caspase-3 were analyzed to determine the protective effects of CA in the presence of IR or taxol. The protective effects of CA were also evaluated using animal models. Results: CA increased stability of the HSF1 protein by phosphorylation at Ser326, which was accompanied by increased expression of HSP27 and HSP70. HSF1 phosphorylation at Ser326 by CA was mediated by EKR1/2 activation. Cotreatment of CA with IR or taxol in normal cells induced protective effects with phosphorylation- dependent patterns at Ser326 of HSF1. The decrease in bone marrow (BM) cellularity and increase of terminal deoxynucleotidyl transferase dUTP nick end labeling–positive BM cells by IR were also significantly inhibited by CA in mice (30.6% and 56.0%, respectively). A549 lung orthotopic lung tumor model indicated that CA did not affect the IR-mediated reduction of lung tumor nodules, whereas CA protected normal lung tissues from the therapeutic irradiation. Conclusions: These results suggest that CA may be useful for inducing HSF1 to protect against normal cell damage after IR or chemotherapeutic agents.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Absorbed Doses and Risk Estimates of {sup 211}At-MX35 F(ab'){sub 2} in Intraperitoneal Therapy of Ovarian Cancer Patients

Purpose: Ovarian cancer is often diagnosed at an advanced stage with dissemination in the peritoneal cavity. Most patients achieve clinical remission after surgery and chemotherapy, but approximately 70% eventually experience recurrence, usually in the peritoneal cavity. To prevent recurrence, intraperitoneal (i.p.) targeted α therapy has been proposed as an adjuvant treatment for minimal residual disease after successful primary treatment. In the present study, we calculated absorbed and relative biological effect (RBE)-weighted (equivalent) doses in relevant normal tissues and estimated the effective dose associated with i.p. administration of {sup 211}At-MX35 F(ab'){sub 2}. Methods and Materials: Patients in clinical remission after salvage chemotherapy for peritoneal recurrence of ovarian cancer underwent i.p. infusion of {sup 211}At-MX35 F(ab'){sub 2}. Potassium perchlorate was given to block unwanted accumulation of {sup 211}At in thyroid and other NIS-containing tissues. Mean absorbed doses to normal tissues were calculated from clinical data, including blood and i.p. fluid samples, urine, γ-camera images, and single-photon emission computed tomography/computed tomography images. Extrapolation of preclinical biodistribution data combined with clinical blood activity data allowed us to estimate absorbed doses in additional tissues. The equivalent dose was calculated using an RBE of 5 and the effective dose using the recommended weight factor of 20. All doses were normalized to the initial activity concentration of the infused therapy solution. Results: The urinary bladder, thyroid, and kidneys (1.9, 1.8, and 1.7 mGy per MBq/L) received the 3 highest estimated absorbed doses. When the tissue-weighting factors were applied, the largest contributors to the effective dose were the lungs, stomach, and urinary bladder. Using 100 MBq/L, organ equivalent doses were less than 10% of the estimated tolerance dose. Conclusion: Intraperitoneal {sup 211}At-MX35 F(ab'){sub 2} treatment is potentially a well-tolerated therapy for locally confined microscopic ovarian cancer. Absorbed doses to normal organs are low, but because the effective dose potentially corresponds to a risk of treatment-induced carcinogenesis, optimization may still be valuable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗