Search NASA⌕ Search

SEARCH · Search NASA

Results for “Particle detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Investigation about decoupling capacitors of PMT voltage divider effects on neutron-gamma discrimination

Scintillators are almost used in any nuclear laboratory. These detectors combine of scintillation materials, PMT and a voltage divider. Voltage dividers are different in resistive ladder design. But the effect of decoupling capacitors and damping resistors haven’t discussed yet. In this paper at first a good equilibrium circuit designed for PMT, and it was used for investigating about capacitors and resistors in much manner. Results show that decoupling capacitors have great effect on PMT output pulses. In this research, it was tried to investigate the effect of Capacitor’s value and places on PMT voltage divider in Neutron-Gamma discrimination capability. Therefore, the voltage divider circuit for R329-02 Hamamatsu PMT was made and Zero Cross method used for neutron-gamma discrimination. The neutron source was a 20Ci Am-Be. Anode and Dynode pulses and discrimination spectrum were saved. The results showed that the pulse height and discrimination quality change with the value and setting of capacitors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fundamental ion cyclotron resonance heating of JET deuterium plasmas

Radio frequency heating of majority ions is of prime importance for understanding the basic role of auxiliary heating in the activated D T phase of ITER. Majority deuterium ion cyclotron resonance heating (ICRH) experiments at the fundamental cyclotron frequency were performed in JET. In spite of the poor antenna coupling at 25 MHz, this heating scheme proved promising when adopted in combination with D neutral beam injection (NBI). The effect of fundamental ICRH of a D population was clearly demonstrated in these experiments: by adding ~25% of heating power the fusion power was increased up to 30 50%, depending on the type of NBI adopted. At this power level, the ion and electron temperatures increased from Ti ~ 4.0 keV and Te ~ 4.5 keV (NBI-only phase) to Ti ~ 5.5 keV and Te ~ 5.2 keV (ICRH + NBI phase), respectively. The increase in the neutron yield was stronger when 80 keV rather than 130 keV deuterons were injected in the plasma. It is shown that the neutron rate, the diamagnetic energy and the electron as well as the ion temperature scale roughly linearly with the applied RF power. A synergistic effect of the combined use of ICRF and NBI heating was observed: (i) the number of neutron counts measured by the neutron camera during the combined ICRF + NBI phases of the discharges exceeded the sum of the individual counts of the NBI-only and ICRF-only phases; (ii) a substantial increase in the number of slowing-down beam ions was detected by the time of flight neutron spectrometer when ICRF power was switched on; (iii) a small D subpopulation with energies slightly above the NBI launch energy was detected by the neutral particle analyzer and -ray spectroscopy.

Krasilnikov, A V↗

QSHS: an axion dark matter resonant search apparatus

We describe a resonant cavity search apparatus for axion dark matter constructed by the quantum sensors for the hidden sector collaboration. The apparatus is configured to search for QCD axion dark matter, though also has the capability to detect axion-like particles, dark photons, and some other forms of wave-like dark matter. Initially, a tuneable cylindrical oxygen-free copper cavity is read out using a low noise microwave amplifier feeding a heterodyne receiver. The cavity is housed in a dilution refrigerator (DF) and threaded by a solenoidal magnetic field, nominally 8 T. The apparatus also houses a magnetic field shield for housing superconducting electronics, and several other fixed-frequency resonators for use in testing and commissioning various prototype quantum electronic devices sensitive at a range of axion masses in the range 2.0–40 μ eV c -2 . The apparatus as currently configured is intended as a test stand for electronics over the relatively wide frequency band attainable with TM 010 the cavity mode used for axion searches. We present performance data for the resonator, DF, and magnet, and plans for the first science run.

Physics - Physics of elementary particles and fiel↗

Constraining sterile neutrinos with AMANDA and IceCube atmospheric neutrino data

We demonstrate that atmospheric neutrino data accumulated with the AMANDA and the partially deployed IceCube experiments constrain the allowed parameter space for a hypothesized fourth sterile neutrino beyond the reach of a combined analysis of all other experiments, for Δm{sup 2}{sub 41}∼<1 eV{sup 2}. Although the IceCube data wins the statistics in the analysis, the advantage of a combined analysis of AMANDA and IceCube data is the partial remedy of yet unknown instrumental systematic uncertainties. We also illustrate the sensitivity of the completed IceCube detector, that is now taking data, to the parameter space of 3+1 model.

79 ASTRONOMY AND ASTROPHYSICS↗

Study of the performance of a large scale water-Cherenkov detector (MEMPHYS)

MEMPHYS (MEgaton Mass PHYSics) is a proposed large-scale water Cherenkov experiment to be performed deep underground. It is dedicated to nucleon decay searches, neutrinos from supernovae, solar and atmospheric neutrinos, as well as neutrinos from a future Super-Beam or Beta-Beam to measure the CP violating phase in the leptonic sector and the mass hierarchy. A full simulation of the detector has been performed to evaluate its performance for beam physics. The results are given in terms of ''migration matrices'' of reconstructed versus true neutrino energy, taking into account all the experimental effects.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The design, implementation, and performance of the LZ calibration systems

LUX-ZEPLIN (LZ) is a tonne-scale experiment searching for direct dark matter interactions and other rare events. It is located at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. The core of the LZ detector is a dual-phase xenon time projection chamber (TPC), designed with the primary goal of detecting Weakly Interacting Massive Particles (WIMPs) via their induced low energy nuclear recoils. Surrounding the TPC, two veto detectors immersed in an ultra-pure water tank enable reducing background events to enhance the discovery potential. Intricate calibration systems are purposely designed to precisely understand the responses of these three detector volumes to various types of particle interactions and to demonstrate LZ's ability to discriminate between signals and backgrounds. In this paper, we present a comprehensive discussion of the key features, requirements, and performance of the LZ calibration systems, which play a crucial role in enabling LZ's WIMP-search and its broad science program. The thorough description of these calibration systems, with an emphasis on their novel aspects, is valuable for future calibration efforts in direct dark matter and other rare-event search experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ML-based calibration and control of the GlueX Central Drift Chamber

The GlueX Central Drift Chamber (CDC) in Hall D at Jefferson Lab, used for detecting and tracking charged particles, is calibrated and controlled during data taking using a Gaussian process. The system dynamically adjusts the high voltage applied to the anode wires inside the chamber in response to changing environmental and experimental conditions such that the gain is stabilized. Control policies have been established to manage the CDC's behavior. These policies are activated when the model's uncertainty exceeds a configurable threshold or during human-initiated tests during normal production running. Finally, we demonstrate the system reduces the time detector experts dedicate to calibration of the data offline, leading to a marked decrease in computing resource usage without compromising detector performance.

47 OTHER INSTRUMENTATION↗

Extending the dark matter reach of water Cherenkov detectors using Jupiter

We propose the first method for water Cherenkov detectors to constrain GeV-scale dark matter (DM) below the solar evaporation mass. While previous efforts have highlighted the Sun and Earth as DM capture targets, we demonstrate that Jupiter is a viable target. Jupiter’s unique characteristics, such as its lower core temperature and significant gravitational potential, allow it to capture and retain light DM more effectively than the Sun, particularly in the mass range below 4 GeV where direct detection sensitivity diminishes. Our calculations provide the first sensitivity estimates to GeV-scale annihilating DM within Jupiter, predicting Hyper-K can reach spin dependent cross sections as low as $𝜎^{SD}_{𝑝⁢𝜒}$ = 2×10 −35 cm 2 for DM masses below 2 GeV. This surpasses current solar limits and direct detection results. We additionally provide estimates for Super-K ORCA, and the IceCube-Upgrade, showing that these experiments could provide complimentary bounds to direct detection experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Metrological resolution and minimum uncertainty states in linear and nonlinear signal detection schemes

We study the performance of linear and nonlinear optical schemes for the detection of weak signals for two classes of probe states. These are quadrature coherent squeezed states and the minimum uncertainty states of the generator of the transformation and the measured observable. Both for linear and nonlinear schemes we show that the generator-measurement minimum uncertainty states are far from being optimum, while the quadrature coherent squeezed states can reach maximum accuracy almost for the same amount of squeezing in both cases. The analysis is largely based on a suitable approximation treating the photon number as a continuous variable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Light-induced atomic desorption for loading a sodium magneto-optical trap

We report studies of photon-stimulated desorption, also known as light-induced atomic desorption, of sodium atoms from a vacuum-cell glass surface used for loading a magneto-optical trap (MOT). Fluorescence detection was used to record the trapped atom number and the desorption rate. We observed a steep wavelength dependence of the desorption process above 2.6 eV photon energy, a result significant for estimations of sodium vapor density in the lunar atmosphere. Our data fit well to a simple model for the loading of the MOT dependent only on the sodium desorption rate and residual gas density. Up to 3.7x10{sup 7} Na atoms were confined under ultrahigh-vacuum conditions, creating promising loading conditions for a vapor-cell-based atomic Bose-Einstein condensate of sodium.

74 ATOMIC AND MOLECULAR PHYSICS↗

Experimental Bell-inequality violation without the postselection loophole

We report on an experimental violation of the Bell-Clauser-Horne-Shimony-Holt (Bell-CHSH) inequality using energy-time-entangled photons. The experiment is not free of the locality and detection loopholes but is the first violation of the Bell-CHSH inequality using energy-time entangled photons which is free of the postselection loophole described by Aerts et al. [Phys. Rev. Lett. 83, 2872 (1999)].

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Photon hole nondemolition measurement scheme by electromagnetically induced transparency

We propose a scheme for quantum nondemolition measurement of photon holes based on electromagnetically induced transparency, which allows direct nondestructive detection of the photon holes. We analyze a scheme based on interaction of a photon hole signal and a coherent probe field with a three-level atomic medium. Using recent advances in electromagnetically induced transparency technology, we show that the measurement is nondestructive for very weak photon hole signals.

74 ATOMIC AND MOLECULAR PHYSICS↗

Distributed quantum computation with arbitrarily poor photon detection

In a distributed quantum computer, scalability is accomplished by networking together many elementary nodes. Typically the network is optical and internode entanglement involves photon detection. In complex networks the entanglement fidelity may be degraded by the twin problems of photon loss and dark counts. Here we describe an entanglement protocol which can achieve high fidelity even when these issues are arbitrarily severe; indeed the method succeeds with finite probability even if the photon detectors are entirely removed from the network. An experimental demonstration should be possible with existing technologies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fast entanglement detection for unknown states of two spatial qutrits

We investigate the practicality of the method proposed by Maciel et al. [Phys. Rev. A. 80, 032325 (2009).] for detecting the entanglement of two spatial qutrits (three-dimensional quantum systems), which are encoded in the discrete transverse momentum of single photons transmitted through a multislit aperture. The method is based on the acquisition of partial information of the quantum state through projective measurements, and a data processing analysis done with semidefinite programs. This analysis relies on generating gradually an optimal entanglement witness operator, and numerical investigations have shown that it allows for the entanglement detection of unknown states with a cost much lower than full state tomography.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum teleportation of four-dimensional qudits

A protocol for the teleportation of arbitrary quantum states of four-dimensional qudits is presented. The qudit to be teleported is encoded in the combined state of two ensembles of atoms placed in a cavity at the sender's side. The receiver uses a similar setup, with his atoms prepared in a particular initial state. The teleportation protocol then consists of adiabatic mapping of the ensemble states onto photonic degrees of freedom, which are then directed onto a specific beam splitter and detection setup. For part of the measurement outcome, the qudit state is fully transferred to the receiver. Other detection events lead to partial teleportation or failed teleportation attempts. The interpretation of the different detection outcomes and possible ways of improving the full teleportation probability are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Purification of noisy quantum measurements

We consider the problem of improving noisy quantum measurements by suitable preprocessing strategies making many noisy detectors equivalent to a single ideal detector. For observables pertaining to finite-dimensional systems (e.g., qubits or spins) we consider preprocessing strategies that are reminiscent of quantum error correction procedures and allow one to perfectly measure an observable on a single quantum system for increasing number of inefficient detectors. For measurements of observables with an unbounded spectrum (e.g., photon number and homodyne and heterodyne detection), the purification of noisy quantum measurements can be achieved by preamplification as suggested by Yuen [Opt. Lett. 12, 789 (1987)].

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Heralding single photons without spectral factorability

Recent efforts to produce single photons via heralding have relied on creating spectrally factorable two-photon states in order to achieve both high purity and high production rate. Through a careful multimode analysis, we find, however, that spectral factorability is not necessary. Utilizing single-mode detection, a similar or better performance can be achieved with nonfactorable states. This conclusion rides on the fact that even when using a broadband filter, a single-mode measurement can still be realized, as long as the coherence time of the triggering photons exceeds the measurement window of the on-off detector.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cloning entangled photons to scales one can see

By amplifying photonic qubits it is possible to produce states that contain enough photons to be seen with the human eye, potentially bringing quantum effects to macroscopic scales [P. Sekatski, N. Brunner, C. Branciard, N. Gisin, and C. Simon, Phys. Rev. Lett. 103, 113601 (2009)]. In this paper we theoretically study quantum states obtained by amplifying one side of an entangled photon pair with different types of optical cloning machines for photonic qubits. We propose a detection scheme that involves lossy threshold detectors (such as the human eye) on the amplified side and conventional photon detectors on the other side. We show that correlations obtained with such coarse-grained measurements prove the entanglement of the initial photon pair and do not prove the entanglement of the amplified state. We emphasize the importance of the detection loophole in Bell violation experiments by giving a simple preparation technique for separable states that violate a Bell inequality without closing this loophole. Finally, we analyze the genuine entanglement of the amplified states and its robustness to losses before, during, and after amplification.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗