Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Some Navier-Stokes calculations for the CAST-10 airfoil

Results of the simulation of the viscous flow past the CAST-10 airfoil were shown for different flow conditions. Since the experiments provide only surface pressures and force coefficients, the comparison to the numerical results relies on these. Good agreement of these results is found for the lower Mach number cases except for the shock position. As numerical experiments indicate, this seems to be due to the turbulent shock boundary layer interaction which is not correctly modelled by the algebraic turbulence model employed. For the lower Mach number case the influence of the transition location was investigated, too. Changing the transition location at the lower surface has much more influence on the pressure distribution than changing it on the upper side. For the higher Mach number case the double shock structure found in the experiment for the lower Reynolds numbers was not reproduced by the numerical solutions. The reason for this is unknown though it may be due to the turbulence modelling. For the higher Reynolds number a better resolution of the boundary layer is needed in the computation in order to recover the experimental pressure plateau; but then the shock position is still found downstream of the experimental one.

Schwamborn, D.↗

FOUR DUAL AGN CANDIDATES OBSERVED WITH THE VLBA

According to hierarchical structure formation models, merging galaxies are expected to be seen in different stages of coalescence. However, there are currently no straightforward observational methods to either select or to confirm a large number of dual active galactic nucleus (AGN) candidates. Most attempts involve obtaining a better understanding of double-peaked narrow emission line sources, in order to distinguish the objects for which the emission lines originate from narrow-line kinematics or jet-driven outflows, from those which might harbor dual AGNs. We observed four such candidate sources with the Very Long Baseline Array (VLBA), at 1.5 GHz with a ∼10 mas angular resolution, for which the spectral profiles of AGN optical emission suggested the existence of dual AGNs. In SDSS J210449.13–000919.1 and SDSS J23044.82–093345.3 the radio structures are aligned with the optical emission features, thus the double-peaked emission lines might be the results of jet-driven outflows. In the third detected source SDSS J115523.74+150756.9, the radio structure is less extended and is oriented nearly perpendicular to the position angle derived from optical spectroscopy. The fourth source remained undetected with the VLBA, but it was imaged with the Very Large Array at arcsec resolution a few months before our observations, suggesting the existence of an extended radio structure. We did not detect two radio-emitting cores in any of the four sources, a convincing signature of duality.

79 ASTRONOMY AND ASTROPHYSICS↗

Reduction of Cysteine Sulfinic Acid in Peroxiredoxin by Sulfiredoxin Proceeds Directly Through a Sulfinic Phosphoryl Ester Intermediate

Sulfiredoxin (Srx) catalyzes a novel enzymatic reaction, the reduction of protein cysteine sulfinic acid, Prx-SO{sub 2}{sup -}. This reaction is unique to the typical 2-Cys peroxiredoxins (Prx) and plays a role in peroxide-mediated signaling by regulating the activity of Prxs. Two mechanistic schemes have been proposed that differ regarding the first step of the reaction. This step involves either the direct transfer of the {gamma}-phosphate of ATP to the Prx molecule or through Srx acting as a phosphorylated intermediary. In an effort to clarify this step of the Srx reaction, we have determined the 1.8 Angstroms resolution crystal structure of Srx in complex with ATP and Mg2+. This structure reveals the role of the Mg2+ ion to position the {gamma}-phosphate toward solvent, thus preventing an in-line attack by the catalytic residue Cys-99 of Srx. A model of the quaternary complex is consistent with this proposal. Furthermore, phosphorylation studies on several site-directed mutants of Srx and Prx, including the Prx-Asp mimic of the Prx-SO{sub 2}{sup -} species, support a mechanism where phosphorylation of Prx-SO{sub 2}{sup -} is the first chemical step.

36 MATERIALS SCIENCE↗

Spectral Line Parameters Including Temperature Dependences of Self- and Air-Broadening in the 2 (left arrow) 0 Band of CO at 2.3 micrometers

Temperature dependences of pressure-broadened half-width and pressure-induced shift coefficients along with accurate positions and intensities have been determined for transitions in the 2<--0 band of C-12 O-16 from analyzing high-resolution and high signal-to-noise spectra recorded with two different Fourier transform spectrometers. A total of 28 spectra, 16 self-broadened and 12 air-broadened, recorded using high- purity (greater than or equal to 99.5% C-12-enriched) CO samples and CO diluted with dry air(research grade) at different temperatures and pressures, were analyzed simultaneously to maximize the accuracy of the retrieved parameters. The sample temperatures ranged from 150 to 298K and the total pressures varied between 5 and 700 Torr. A multispectrum nonlinear least squares spectrum fitting technique was used to adjust the rovibrational constants (G, B, D, etc.) and intensity parameters (including Herman-Wallis coefficients), rather than determining individual line positions and intensities. Self-and air-broadened Lorentz half-width coefficients, their temperature dependence exponents, self- and air-pressure-induced shift coefficients, their temperature dependences, self- and air-line mixing coefficients, their temperature dependences and speed dependence have been retrieved from the analysis. Speed-dependent line shapes with line mixing employing off-diagonal relaxation matrix element formalism were needed to minimize the fit residuals. This study presents a precise and complete set of spectral line parameters that consistently reproduce the spectrum of carbon monoxide over terrestrial atmospheric conditions.

Devi, V. Malathy↗

Time-resolved x-ray radiography of spark ignition plasma

Understanding the short-lived structure of the plasma that forms between the electrodes of a spark plug is crucial to the development of improved ignition models for SI engines. However, measuring the amount of energy deposited in the gas directly and non-intrusively is difficult, due to the short time scales and small length scales involved. The breakdown of the spark gap occurs at nanosecond time scales, followed by an arc phase lasting a few microseconds. Finally, a glow discharge phase occurs over several milliseconds. It is during the arc and glow discharge phases that most of the heat transfer from the plasma to the electrodes and combustion gases occurs. Light emission can be used to measure an average temperature, but micron spatial resolution is required to make localized measurements. In this paper, we present the results of a proof of concept experiment that demonstrates the use of time-resolved x-ray radiography to measure the density of the plasma in the spark gap during the glow discharge phase of a conventional transistorized coil ignition system. A focused monochromatic x-ray beam from the 7-BM beamline of the Advanced Photon Source at Argonne National Laboratory was used to make time-resolved point measurements of the projected density, which decreases as the plasma temperature increases. Multiple measurement positions were combined to produce a two-dimensional map of the projected density both inside and surrounding the spark gap. A temporal resolution of 153 ns and spatial resolution of 5 μm were achieved. A range of ambient gases, densities (1 - 3 bar) and ignition coil charging durations (1 - 2.5 ms) were considered. At least 30 repeated measurements were made for each sample point and condition. All these parameters were found to substantially alter the structure of the plasma as measured by x-ray radiography. From the projected density measurements, changes in thermal energy can be calculated. These provide a quantitative measurement of the energy deposited into the gas; this is only a small fraction of the total spark energy. The measurements demonstrate the feasibility of time-resolved x-ray radiography for the study of plasma structure and development for SI applications.

Kastengren, Alan L.↗

Performance characterization of 5×5×12 mm 3 virtual Frisch-grid TlBr detectors

Thallium bromide (TlBr) is a promising material for semiconductor gamma-ray detectors due to its high atomic number (Tl = 81, Br = 35), high density (7.56 g/cm 3 ), and relatively low melting point (460 °C). These properties give TlBr several competitive features, including high detection efficiency, good energy resolution, and lower fabrication costs, making it suitable for applications requiring compact, highly sensitive gamma-ray detection systems. Recent developments of TlBr detectors have progressed toward thicker crystals, up to 10–20 mm, configured as pixelated or virtual Frisch-grid (VFG) devices with volumes >1 cm 3 . Despite these advances, challenges remain in practical implementation, including material and fabrication issues that affect energy resolution, device stability, performance, and longevity. These challenges are similar to those faced by HgI 2 and lead-halide perovskite detectors. Here, this study presents results from characterizing over 100 position-sensitive 5×5×12 mm 3 virtual Frisch-grid detectors fabricated by Radiation Monitoring Devices Inc. For a prototype Radioisotope Identification Device (RIID). The work identified factors limiting the performance and longevity of TlBr detectors, including stochastic response variations that limit the energy resolution to 2–3 % (at 662 keV) for most devices, performance degradation associated with defect decoration, and contact delamination. Addressing these issues advances the use of TlBr and similar materials for reliable, high-resolution gamma-ray spectroscopy.

47 OTHER INSTRUMENTATION↗

Modeling organic aerosols in a megacity: potential contribution of semi-volatile and intermediate volatility primary organic compounds to secondary organic aerosol formation

It has been established that observed local and regional levels of secondary organic aerosols (SOA) in polluted areas cannot be explained by the oxidation and partitioning of traditional anthropogenic and biogenic VOC precursors. In this study, the 3D regional air quality model CHIMERE is applied to quantify the contribution to SOA formation of recently identified semi-volatile and intermediate volatility organic vapors (S/IVOC) in and around Mexico City for the MILAGRO field experiment during March 2006. The model has been updated to explicitly include the volatility distribution of primary organic aerosols (POA), their gas-particle partitioning and the gas-phase oxidation of the vapors. Two recently proposed parameterizations, those of Robinson et al. (2007) ("ROB") and Grieshop et al. (2009) ("GRI") are compared and evaluated against surface and aircraft measurements. For the first time, 3D model results are assessed by comparing with the concentrations of OA components from Positive Matrix Factorization of Aerosol Mass Spectrometer (AMS) data, but also against and oxygen-to-carbon ratios derived from high-resolution AMS measurements. The results show a substantial enhancement in predicted SOA concentrations (3-6 times) with respect to the previously published base case without S/IVOCs (Hodzic et al., 2009), both within and downwind of the city leading to much reduced discrepancies with the total OA measurements. The predicted anthropogenic POA levels are found to agree within 20% with the observed HOA concentrations for both the ROB and GRI simulations, consistent with the interpretation of the emissions inventory by previous studies. The impact of biomass burning POA within the city is underestimated in comparison to the AMS BBOA, presumably due to insufficient nighttime smoldering emissions. Model improvements in OA predictions are associated with the better-captured SOA magnitude and diurnal variability. The production from anthropogenic and biomass burning S/IVOC represents 40-60% of the total SOA at the surface during the day and is somewhat larger than that from aromatics, especially at the T1 site at the edge of the city. The downwind SOA production from the continued multi-generation S/IVOC oxidation products actively continues. Similar to aircraft observations, the predicted OA/DCO ratio for the ROB case increases from 20-30 mg sm-3 ppm-1 up to 60-70 mg sm-3 ppm-1 between a fresh and 1-day aged air mass, while the GRI case produces a 30-40% higher OA growth than observed. The predicted average O/C ratio of total OA for the ROB case is 0.16 at T0, substantially below observed value of 0.5. A much better agreement for O/C ratios and temporal variability (R2=0.63) is achieved with the updated GRI treatment. Both treatments show a deficiency in regard to POA evolution with a tendency to over-evaporate POA upon dilution of the urban plume suggesting that atmospheric HOA may be less volatile than assumed in these parameterizations. This study highlights the very important potential role of S/IVOC chemistry in the SOA budget in this region, and highlights the need for improvements in current parameterizations. We note that other proposed pathways of SOA formation such as formation from very volatile species like glyoxal were not included in our simulations, which can also contribute SOA mass and especially increase the O/C ratio.

Hodzic, Alma↗

SU-F-J-135: Tumor Displacement-Based Binning for Respiratory-Gated Time-Independent 5DCT Treatment Planning

Purpose: A published 5DCT breathing motion model enables image reconstruction at any user-selected breathing phase, defined by the model as a specific amplitude (v) and rate (f). Generation of reconstructed phase-specific CT scans will be required for time-independent radiation dose distribution simulations. This work answers the question: how many amplitude and rate bins are required to describe the tumor motion with a specific spatial resolution? Methods: 19 lung-cancer patients with 21 tumors were scanned using a free-breathing 5DCT protocol, employing an abdominally positioned pneumatic-bellows breathing surrogate and yielding voxel-specific motion model parameters α and β corresponding to motion as a function of amplitude and rate, respectively. Tumor GTVs were contoured on the first (reference) of 25 successive free-breathing fast helical CT image sets. The tumor displacements were binned into widths of 1mm to 5mm in 1mm steps and the total required number of bins recorded. The simulation evaluated the number of bins needed to encompass 100% of the breathing-amplitude and between the 5th and 95th percentile amplitudes to exclude breathing outliers. Results: The mean respiration-induced tumor motion was 9.90mm ± 7.86mm with a maximum of 25mm. The number of bins required was a strong function of the spatial resolution and varied widely between patients. For example, for 2mm bins, between 1–13 amplitude bins and 1–9 rate bins were required to encompass 100% of the breathing amplitude, while 1–6 amplitude bins and 1–3 rate bins were required to encompass 90% of the breathing amplitude. Conclusion: The strong relationship between number of bins and spatial resolution as well as the large variation between patients implies that time-independent radiation dose distribution simulations should be conducted using patient-specific data and that the breathing conditions will have to be carefully considered. This work will lead to the assessment of the dosimetric impact of binning resolution. This study is supported by Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗

A high resolution and large solid angle x-ray Raman spectroscopy end-station at the Stanford Synchrotron Radiation Lightsource

We present a new x-ray Raman spectroscopy end-station recently developed, installed, and operated at the Stanford Synchrotron Radiation Lightsource. The end-station is located at wiggler beamline 6-2 equipped with two monochromators-Si(111) and Si(311) as well as collimating and focusing optics. It consists of two multi-crystal Johann type spectrometers arranged on intersecting Rowland circles of 1 m diameter. The first one, positioned at the forward scattering angles (low-q), consists of 40 spherically bent and diced Si(110) crystals with 100 mm diameters providing about 1.9% of 4{pi} sr solid angle of detection. When operated in the (440) order in combination with the Si (311) monochromator, an overall energy resolution of 270 meV is obtained at 6462.20 eV. The second spectrometer, consisting of 14 spherically bent Si(110) crystal analyzers (not diced), is positioned at the backward scattering angles (high-q) enabling the study of non-dipole transitions. The solid angle of this spectrometer is about 0.9% of 4{pi} sr, with a combined energy resolution of 600 meV using the Si (311) monochromator. These features exceed the specifications of currently existing relevant instrumentation, opening new opportunities for the routine application of this photon-in/photon-out hard x-ray technique to emerging research in multidisciplinary scientific fields, such as energy-related sciences, material sciences, physical chemistry, etc.

43 PARTICLE ACCELERATORS↗

General Aviation Citizen Science Study to Help Tackle Remote Sensing of Harmful Algal Blooms (HABs)

We present a new, low-cost approach, based on volunteer pilots conducting high-resolution aerial imaging, to help document the onset, growth, and outbreak of harmful algal blooms (HABs) and related water quality issues in central and western Lake Erie. In this model study, volunteer private pilots acting as citizen scientists frequently flew over 200 mi of Lake Erie coastline, its islands, and freshwater estuaries, taking high-quality aerial photographs and videos. The photographs were taken in the nadir (vertical) position in red, green, and blue (RGB) and near-infrared (NIR) every 5 s with rugged, commercially available built-in Global Positioning System (GPS) cameras. The high-definition (HD) videos in 1080p format were taken continuously in an oblique forward direction. The unobstructed, georeferenced, high-resolution images, and HD videos can provide an early warning of ensuing HAB events to coastal communities and freshwater resource managers. The scientists and academic researchers can use the data to compliment a collection of in situ water measurements, matching satellite imagery, and help develop advanced airborne instrumentation, and validation of their algorithms. This data may help develop empirical models, which may lead to the next steps in predicting a HAB event as some watershed observed events changed the water quality such as particle size, sedimentation, color, mineralogy, and turbidity delivered to the Lake site. This paper shows the efficacy and scalability of citizen science (CS) aerial imaging as a complimentary tool for rapid emergency response in HABs monitoring, land and vegetation management, and scientific studies. This study can serve as a model for monitoring/management of freshwater and marine aquatic systems.

Ansari, Rafat R.↗

High-resolution imaging with a tip-tilt Cassegrain secondary

A prototype adaptive secondary mirror has been developed on a 2.3-m telescope to stabilize rapid motion caused by atmospheric turbulence. The instantaneous position of an image's centroid, or brightest speckle, is measured by a near-infrared camera system which enables the tip-tilt mirror to recenter the image. Correction is accomplished at closed-loop frequencies of less than or = 100 Hz on guide stars with K (2.2 micrometers) magnitudes less than or = 8. Image motion is reduced to less than 0.1 sec rms, removing over 90% of low-frequency (f less than or = 5 Hz) tilt power, leaving less than or = 1 rad exp 2 mean square wave front tilt phase error. In seeing conditions where D/r sub o approximately = 4, long exposures in the H band (1.6 micrometers) exhibit a nearly diffraction-limited resolution of 0.19 sec full width at half maximum (FWHM) (Strehl ratio aprroximately = 0.14)-a factor of 4 improvement over uncorrected images. Reduction of the present static optical errors will improve the Strehl ratio another factor of 2, leading to approximately 70% of the maximum possible Strehl ratio.

Close, L. M.↗

A Resonant Cavity Approach to Non-Invasive, Pulse-to-Pulse EmittanceMeasurement

We present a resonant cavity approach for non-invasive, pulse-to-pulse, beam emittance measurements of non-circular multi-bunch beams. In a resonant cavity, desired field components can be enhanced up to Q{sub L{lambda}}/{pi}, where Q{sub L{lambda}} is the loaded quality factor of the resonant mode {lambda}, when the cavity resonant mode matches the bunch frequency of a bunch-train beam pulse. In particular, a quad-cavity, with its quadrupole mode (TM{sub 220} for rectangular cavities) at beam operating frequency, rotated 45{sup o} with respect to the beamline, extracts the beam quadrupole moment exclusively, utilizing the symmetry of the cavity and some simple networks to suppress common modes. Six successive beam quadrupole moment measurements, performed at different betatron phases in a linear transport system determine the beam emittance, i.e. the beam size and shape in the beam's phase space, if the beam current and position at these points are known. In the presence of x-y beam coupling, ten measurements are required. One measurement alone provides the rms-beam size of a large aspect ratio beam. The resolution for such a measurement of rms-beam size with the rectangular quad-cavity monitor presented in this article is estimated to be on the order of ten microns. A prototype quad-cavity was fabricated and preliminary beam tests were performed at the Next Linear Collider Test Accelerator (NLCTA) at the Stanford Linear Accelerator Center (SLAC). Results were mainly limited by beam jitter and uncertainty in the beam position measurement at the cavity location. This motivated the development of a position-emittance integrated monitor.

43 PARTICLE ACCELERATORS↗

Decoding Golden Eagle Movement Behavior from High-Resolution, Variable-Rate Telemetry Data Through Bayesian Filtering

The recent advances in animal tracking technology have enabled the collection of a vast amount of in situ data regarding the movement of wildlife at high spatiotemporal resolution. These data are usually available at variable time resolutions and contains noise (error) originating from GPS fixes. Decoding movement characteristics, particularly of flying animals, from telemetry data while handling these factors is a challenging yet important task for conservation purposes. Typically, this task is broken into two subtasks: resampling, and model calibration. The resampling subtask converts the variable rate positional data into a constant time interval data, while the model calibration subtask uses the resampled data to tune time-invariant parameters of the proposed models. For telemetry data at high temporal resolutions (order of 1 second), it is very challenging to decouple noise from actual movements using interpolation-based resampling techniques. Any errors introduced during resampling can significantly alter the the calibration and prediction attributes of the movement model. We address this problem through a unified Bayesian state-space framework that can handle both the resampling and calibration tasks in a single step. In addition, we use the speed and heading of the bird from telemetry data to regularize the position information of the bird. We use a Kalman filtering approach to include these nonlinearly related motion parameters within the state space framework. We cross-validated to quantify how this inclusion affects the model performance in estimating true bird movements. The relationship between the true state of the bird and environmental and topographical covariates is then represented parametrically. These parameters are then tuned using stochastic sampling strategies like Markov Chain Monte Carlo (MCMC). We use the telemetry data collected from golden eagles in the western USA to demonstrate the applicability of this approach to build a predictive, probabilistic movement model. Our preliminary results show that this approach provides improved predictive performance in terms of capturing higher-order motion parameters such as angular and horizontal accelerations, which may have simpler and more direct relationships with environmental covariates than corresponding speeds. In this talk, we will demonstrate how this state-space approach benefits the prediction capabilities of a movement model in simulating golden eagle paths through a wind power plant in Wyoming given certain atmospheric conditions. The model outcomes are aimed at informing mitigation strategies that can minimize the potential for collisions of golden eagles with wind turbines.

Bayesian methods↗

The (d,{sup 2}He) reaction on {sup 96}Mo and the double-{beta} decay matrix elements for {sup 96}Zr

The {sup 96}Mo(d,{sup 2}He){sup 96}Nb charge-exchange reaction was investigated at an incident energy of E{sub d}=183.5 MeV. An excitation-energy resolution of 110 keV was achieved. The experiment was performed at KVI, Groningen, using the magnetic spectrometer BBS at three angular positions: 0 deg., 2.5 deg., and 6 deg. We found that below 6 MeV almost the entire Gamow-Teller (GT{sup +}) strength is concentrated in a single state at 0.69 MeV excitation energy. As {sup 96}Mo is the daughter of the {beta}{beta} decay nucleus {sup 96}Zr, the present result provides information about the nuclear matrix elements active in the 2{nu}{beta}{beta} decay of {sup 96}Zr.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Structural Basis for the Catalytic Activity of Human SER/THR Protein Phosphatase-5

Serinekhreonine protein phosphatase-5 (PP5) affects many signaling networks that regulate cell growth. Here we report the 1.6 Angstrom resolution crystal structure of PP5 catalytic domain with metal and phosphate ions in the active site. The structure reveals a mechanism for PPS-mediated catalysis that requires the precise positioning of two metal ions within a conserved Asp(sup 271)-M(sub 1),-M(sub 2)-His(sup 427)-W(sup 2)-His(sup 304)-Asp(sup 274) catalytic motif, and provides a structural basis for the exceptional catalytic proficiency of protein phosphatases placing them among the most powerful catalysts. Resolution of the entire C-terminus revealed a novel subdomain, and the structure of PP5 should aid development of specific inhibitors.

Swingle, M. R.↗

Scanning transmission electron microscopy strain measurement from millisecond frames of a direct electron charge coupled device

A high-speed direct electron detection system is introduced to the field of transmission electron microscopy and applied to strain measurements in semiconductor nanostructures. In particular, a focused electron probe with a diameter of 0.5 nm was scanned over a fourfold quantum layer stack with alternating compressive and tensile strain and diffracted discs have been recorded on a scintillator-free direct electron detector with a frame time of 1 ms. We show that the applied algorithms can accurately detect Bragg beam positions despite a significant point spread each 300 kV electron causes during detection on the scintillator-free camera. For millisecond exposures, we find that strain can be measured with a precision of 1.3 Multiplication-Sign 10{sup -3}, enabling, e.g., strain mapping in a 100 Multiplication-Sign 100 nm{sup 2} region with 0.5 nm resolution in 40 s.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Megavoltage Computed Tomography Image Guidance With Helical Tomotherapy in Patients With Vertebral Tumors: Analysis of Factors Influencing Interobserver Variability

Purpose: To evaluate megavoltage computed tomography (MVCT)-based image guidance with helical tomotherapy in patients with vertebral tumors by analyzing factors influencing interobserver variability, considered as quality criterion of image guidance. Methods and Materials: Five radiation oncologists retrospectively registered 103 MVCTs in 10 patients to planning kilovoltage CTs by rigid transformations in 4 df. Interobserver variabilities were quantified using the standard deviations (SDs) of the distributions of the correction vector components about the observers' fraction mean. To assess intraobserver variabilities, registrations were repeated after {>=}4 weeks. Residual deviations after setup correction due to uncorrectable rotational errors and elastic deformations were determined at 3 craniocaudal target positions. To differentiate observer-related variations in minimizing these residual deviations across the 3-dimensional MVCT from image resolution effects, 2-dimensional registrations were performed in 30 single transverse and sagittal MVCT slices. Axial and longitudinal MVCT image resolutions were quantified. For comparison, image resolution of kilovoltage cone-beam CTs (CBCTs) and interobserver variability in registrations of 43 CBCTs were determined. Results: Axial MVCT image resolution is 3.9 lp/cm. Longitudinal MVCT resolution amounts to 6.3 mm, assessed as full-width at half-maximum of thin objects in MVCTs with finest pitch. Longitudinal CBCT resolution is better (full-width at half-maximum, 2.5 mm for CBCTs with 1-mm slices). In MVCT registrations, interobserver variability in the craniocaudal direction (SD 1.23 mm) is significantly larger than in the lateral and ventrodorsal directions (SD 0.84 and 0.91 mm, respectively) and significantly larger compared with CBCT alignments (SD 1.04 mm). Intraobserver variabilities are significantly smaller than corresponding interobserver variabilities (variance ratio [VR] 1.8-3.1). Compared with 3-dimensional registrations, 2-dimensional registrations have significantly smaller interobserver variability in the lateral and ventrodorsal directions (VR 3.8 and 2.8, respectively) but not in the craniocaudal direction (VR 0.75). Conclusion: Tomotherapy image guidance precision is affected by image resolution and residual deviations after setup correction. Eliminating the effect of residual deviations yields small interobserver variabilities with submillimeter precision in the axial plane. In contrast, interobserver variability in the craniocaudal direction is dominated by the poorer longitudinal MVCT image resolution. Residual deviations after image guidance exist and need to be considered when dose gradients ultimately achievable with image guided radiation therapy techniques are analyzed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving the characterization of fusion in a MuSIC detector by spatial localization

Multi-Sampling Ionization Chambers (MuSIC) provide an efficient means of measuring nuclear reactions with low beam rates (< 10 6 pps). However, in comparison to thin-target measurements, prior measurements using MuSIC detectors all manifest fusion excitation functions with wide error bars in the energy dimension. This uncertainty limits the applicability of these devices in measuring near and sub-barrier fusion cross-sections. Key to overcoming this limitation is spatial localization of the fusion in the detector. By comparing the measured ionization in the MuSIC detector with accurate energy loss calculations the position of the fusion in the detector is determined. The analysis not only provides the desired improvement in energy resolution, but it also allows extraction of the atomic number of the evaporation residues following fusion. Furthermore, the effectiveness of this approach is demonstrated for 18 O+ 12 C measured with MuSIC@Indiana.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗