Search NASA⌕ Search

SEARCH · Search NASA

Results for “Positioning Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Measurement of sheared flows in the edge plasma of the CASTOR tokamak

The ion saturation current and floating potential are measured with high temporal (1 {mu}s) and spatial (2.5 mm) resolutions at the plasma edge of the CASTOR tokamak by two poloidally spaced radial arrays of Langmuir probes. The radial electric field and the phase velocity of plasma fluctuations are estimated. The position of the velocity shear layer (VSL) is localized with a high precision. The shearing rate {omega}{sub ExB} determined and found to be comparable with the inverse of the correlation time of fluctuations 1/{tau}{sub ac} outside the VSL and about five times higher in the proximity of the VSL. A small impact of the shear on fluctuation level at the VSL is observed also in the statistic parameters of the U{sub fl} and I{sub sat}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Medial axis and local thickness computation using the Fast Sweeping Method

This report describes an efficient and robust voxel-based methodology for computing the medial axis, local thickness, and distance-to-skeleton of arbitrary three-dimensional geometries. It is assumed that the object can be represented by an exact or approximate signed distance function on a discrete grid. The gradient of such function is used to formulate a hyperbolic partial differential equation (PDE) that models the collapse of the position vector in space. By exploiting the causality property of the PDE, the Fast Sweeping Method is able to obtain the solution in a finite number of sweeps independent of the mesh resolution. The intersection of characteristic lines leads to the formation of shocks and a discrete bisector function is used to identify the medial axis. The same PDE approach is used to compute the local thickness inside the object and obtain the distance-to-skeleton field. Multiple examples are given in two and three dimensions along with a resolution study. The methodology has optimal complexity and yields subsecond computational times for geometries with over a million zones on a single core. The methodology is also capable of parallelization across shared and distributed memory architectures.

97 MATHEMATICS AND COMPUTING↗

Machine and Deep Learning: Artificial Intelligence Application in Biotic and Abiotic Stress Management in Plants

Biotic and abiotic stresses significantly affect plant fitness, resulting in a serious loss in food production. Biotic and abiotic stresses predominantly affect metabolite biosynthesis, gene and protein expression, and genome variations. However, light doses of stress result in the production of positive attributes in crops, like tolerance to stress and biosynthesis of metabolites, called hormesis. Advancement in artificial intelligence (AI) has enabled the development of high-throughput gadgets such as high-resolution imagery sensors and robotic aerial vehicles, i.e., satellites and unmanned aerial vehicles (UAV), to overcome biotic and abiotic stresses. These High throughput (HTP) gadgets produce accurate but big amounts of data. Significant datasets such as transportable array for remotely sensed agriculture and phenotyping reference platform (TERRA-REF) have been developed to forecast abiotic stresses and early detection of biotic stresses. For accurately measuring the model plant stress, tools like Deep Learning (DL) and Machine Learning (ML) have enabled early detection of desirable traits in a large population of breeding material and mitigate plant stresses. In this review, advanced applications of ML and DL in plant biotic and abiotic stress management have been summarized.

59 BASIC BIOLOGICAL SCIENCES↗

HOLISTIC ENERGY EFFICIENCY ANALYSIS OF ELECTRIFIED OFF-HIGHWAY MATERIAL HANDLER: FROM DRIVE CYCLE CHARACTERIZATION TO POWERTRAIN, HYDRAULIC, AND THERMAL SYSTEM PERFORMANCE

Three complexities surrounding the operation and testing of hybrid electric, heavy-duty nonroad machines have been addressed experimentally and using 1D simulation. Their resolutions have been intertwined with the development of a prototype machine that was proven to reduce fuel consumption in excess of 20%. A real-world drive cycle that leveraged hydraulic cylinder position was developed and utilized to ensure accurate reproduction of hydraulic work between the baseline and hybrid machines, while simultaneously maintaining less than 5% RMS error in position for main load handling functions. The newly developed, machine-specific drive cycle also contributed towards making equivalent comparisons in energy consumption between machine types through composite performance metrics that were extrapolated over a typical shift duration. Lastly, this work addressed thermal management energy consumption, a topic of increasing popularity when discussing electrified vehicles, by proposing a 1.4% energy savings through special mechanization and control of cooling system components.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radial Velocities, Space Motions, and Nearby Young Moving Group Memberships of Eleven Candidate Young Brown Dwarfs

We present new radial velocity (RV) measurements for 11 candidate young very-low-mass stars and brown dwarfs, with spectral types from M7 to L7. Candidate young objects were identified by features indicative of low surface gravity in their optical and/or near-infrared spectra. RV measurements are derived from high-resolution (R =λ/Δλ = 20,000) J-band spectra taken with NIRSPEC at the Keck Observatory. We combine RVs with proper motions and trigonometric distances to calculate three-dimensional space positions and motions and to evaluate membership probabilities for nearby young moving groups (NYMGs). We propose 2MASS J00452143+1634446 (L2β, J = 13.06) as an RV standard given the precision and stability of measurements from three different studies. We test the precision and accuracy of our RV measurements as a function of spectral type of the comparison object, finding that RV results are essentially indistinguishable even with differences of ±5 spectral subtypes. We also investigate the strengths of gravity-sensitive K i lines at 1.24–1.25 μm and evaluate their consistency with other age indicators. We confirm or reconfirm four brown dwarf members of NYMGs—2MASS J00452143+1634446, WISE J00470038+6803543, 2MASS J011747483403258, and 2MASS J193555952846343—and their previous age estimates. We identify one new brown dwarf member of the Carina-Near moving group, 2M2154−10. The remaining objects do not appear to be members of any known NYMGs, despite their spectral signatures of youth. These results add to the growing number of very-low-mass objects exhibiting signatures of youth that lack likely membership in a known NYMG, thereby compounding the mystery regarding local, low-density star formation.

79 ASTRONOMY AND ASTROPHYSICS↗

3D Millimeter Event Localization in Bulk Scintillator Crystals

One of the primary goals of scintillator-based gamma-ray detector development is to obtain spatial resolutions in bulk crystals at the millimeter level in all three spatial dimensions. An even more challenging goal is to disentangle multiple simultaneous energy depositions with comparable spatial resolutions. We are exploring a new technique to achieve this level of performance through the use of close-coupled, coded-aperture shadow masks placed between the crystal and a position-sensitive phototransducer. We report on simulations of such a device using Monte Carlo light transport simulations performed with GEANT4. Initial indications are promising; however, the technique will require a very high level of performance from the phototransducer.

Ziock, Klaus-Peter↗

On-board Radiation Sensor and Low-Altitude Contour Mapping of Radiation Fields using UAS Swarm - 18239

This paper addresses the design of light weight radiation sensors for the small-scale unmanned aerial system (UAS), and its implementation for low-altitude radiation source localization and contour mapping. The compact, high-resolution gamma-ray CZT sensors were integrated to UAS platforms as plug-and-play components using Robot Operation System (ROS). In this work, the UAS swarm consists of three platforms positioned in circular formation. The onboard data analysis provides time and position stamped intensities of gamma-ray peaks for each UAS-based sensor that are used as the input data for the swarm flight control algorithm. Each UAS measures radiation simultaneously for estimating gradient of radiation to compute a bulk heading angle of the swarm for contour mapping, which can provide relatively precise boundary of the safe area for potential human exploration. The UAS radiation sensors allow measurements from just few meters up to hundreds of meters thus filling the gap between land- and helicopter- based platforms. The swarm of UAS has advantages over a single agent based approach in detecting radiative sources and effectively mapping the area. The proposed method can locate sources of radiation as well as mapping the contaminated area for enhancing situation awareness capabilities for first responders. Computer simulation is presented for UAS swarm based source localization and contour mapping in the simulated radiation fields created by the MCNP code. Selected key gradient estimation and contour mapping algorithms are validated experimentally with small scale multicopter UAS in the indoor flight test bed. (authors)

42 ENGINEERING↗

A Comprehensive Approach to Gamma-Ray Source Identification in the GLAST-LAT Era

Unveiling the nature of a vast number of unidentified sources is the most compelling problem facing today's high-energy (MeV-to-GeV) gamma-ray astronomy. However, unidentified sources are not peculiar to high-energy gamma-ray astronomy, they have been an ever-present phenomenon in astronomy. Indeed, every time a new astronomical window was opened, astronomers found sources they were not able to identify, i.e. to associate with previously known objects. This can happen either because such sources belong to a genuinely new (thus unknown) class or because their positions are not known accurately enough to allow for an unambiguous association between the newly found emitter and a known object. Thus, the lack of identification is frequently ascribed to poor angular resolution. Being unidentified, however, is a 'temporary' status: sooner or later better tools will allow the source identification, i.e. either its classification within a given class of astronomical objects or its recognition as belonging to a new class. Owing to the intrinsic limitations of gamma-ray detection technique, however, the instruments' angular resolution has not yet reached the minimum level required to permit the transition from the unidentified limbo to the paradise of known objects, thus creating a continuing unidentified high-energy gamma-ray source problem. Different approaches towards source identification have been pursued in the past. Here we will review the state of the art as well as the strategies devised for the GLAST era.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Chasing the open-state structure of pentameric ligand-gated ion channels

Remarkable advances have been made toward the structural characterization of ion channels in the last two decades. However, the unambiguous assignment of well-defined functional states to the obtained structural models has proved challenging. In the case of the superfamily of nicotinic-receptor channels (also referred to as pentameric ligand-gated ion channels [pLGICs]), for example, two different types of model of the open-channel conformation have been proposed on the basis of structures solved to resolutions better than 4.0 Å. At the level of the transmembrane pore, the open-state models of the proton-gated pLGIC from Gloeobacter violaceus (GLIC) and the invertebrate glutamate-gated Cl – channel (GluCl) are very similar to each other, but that of the glycine receptor (GlyR) is considerably wider. Indeed, the mean distances between the axis of ion permeation and the Cα atoms at the narrowest constriction of the pore (position -2') differ by ~2 Å in these two classes of model, a large difference when it comes to understanding the physicochemical bases of ion conduction and charge selectivity. Here, we take advantage of the extreme open-channel stabilizing effect of mutations at pore-facing position 9'. We find that the I9'A mutation slows down entry into desensitization of GLIC to the extent that macroscopic currents decay only slightly by the end of pH 4.5 solution applications to the extracellular side for several minutes. We crystallize (at pH 4.5) two variants of GLIC carrying this mutation and solve their structures to resolutions of 3.12 Å and 3.36 Å. Furthermore, we perform all-atom molecular dynamics simulations of ion permeation and picrotoxinin block, using the different open-channel structural models. On the basis of these results, we favor the notion that the open-channel structure of pLGICs from animals is much closer to that of the narrow models (of GLIC and GluCl) than it is to that of the GlyR.

Gonzalez-Gutierrez, Giovanni↗

WE-AB-BRB-12: Nanoscintillator Fiber-Optic Detector System for Microbeam Radiation Therapy Dosimetry

Purpose: Microbeam Radiation Therapy (MRT) is an experimental radiation therapy that has demonstrated a higher therapeutic ratio than conventional radiation therapy in animal studies. There are several roadblocks in translating the promising treatment technology to clinical application, one of which is the lack of a real-time, high-resolution dosimeter. Current clinical radiation detectors have poor spatial resolution and, as such, are unsuitable for measuring microbeams with submillimeter-scale widths. Although GafChromic film has high spatial resolution, it lacks the real-time dosimetry capability necessary for MRT preclinical research and potential clinical use. In this work we have demonstrated the feasibility of using a nanoscintillator fiber-optic detector (nanoFOD) system for real-time MRT dosimetry. Methods: A microplanar beam array is generated using a x-ray research irradiator and a custom-made, microbeam-forming collimator. The newest generation nanoFOD has an effective size of 70 µm in the measurement direction and was calibrated against a kV ion chamber (RadCal Accu-Pro) in open field geometry. We have written a computer script that performs automatic data collection with immediate background subtraction. A computer-controlled detector positioning stage is used to precisely measure the microbeam peak dose and beam profile by translating the stage during data collection. We test the new generation nanoFOD system, with increased active scintillation volume, against the previous generation system. Both raw and processed data are time-stamped and recorded to enable future post-processing. Results: The real-time microbeam dosimetry system worked as expected. The new generation dosimeter has approximately double the active volume compared to the previous generation resulting in over 900% increase in signal. The active volume of the dosimeter still provided the spatial resolution that meets the Nyquist criterion for our microbeam widths. Conclusion: We have demonstrated that real-time dosimetry of MRT microbeams is feasible using a nanoscintillator fiber-optic detector with integrated positioning system.

60 APPLIED LIFE SCIENCES↗

Dynamics of ionization processes in high-pressure nitrogen, air, and SF{sub 6} during a subnanosecond breakdown initiated by runaway electrons

The dynamics of ionization processes in high-pressure nitrogen, air, and SF{sub 6} during breakdown of a gap with a nonuniform distribution of the electric field by nanosecond high-voltage pulses was studied experimentally. Measurements of the amplitude and temporal characteristics of a diffuse discharge and its radiation with a subnanosecond time resolution have shown that, at any polarity of the electrode with a small curvature radius, breakdown of the gap occurs via two ionization waves, the first of which is initiated by runaway electrons. For a voltage pulse with an ∼500-ps front, UV radiation from different zones of a diffuse discharge is measured with a subnanosecond time resolution. It is shown that the propagation velocity of the first ionization wave increases after its front has passed one-half of the gap, as well as when the pressure in the discharge chamber is reduced and/or when SF{sub 6} is replaced with air or nitrogen. It is found that, at nitrogen pressures of 0.4 and 0.7 MPa and the positive polarity of the high-voltage electrode with a small curvature radius, the ionization wave forms with a larger (∼30 ps) time delay with respect to applying the voltage pulse to the gap than at the negative polarity. The velocity of the second ionization wave propagating from the plane electrode is measured. In a discharge in nitrogen at a pressure of 0.7 MPa, this velocity is found to be ∼10 cm/ns. It is shown that, as the nitrogen pressure increases to 0.7 MPa, the propagation velocity of the front of the first ionization wave at the positive polarity of the electrode with a small curvature radius becomes lower than that at the negative polarity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Crystal structure of human esterase D: a potential genetic marker of retinoblastoma

Retinoblastoma (RB), a carcinoma of the retina, is caused by mutations in the long arm of chromosome 13, band 13q14. The esterase D (ESD) gene maps at a similar location as the RB gene locus and therefore serves as a potential marker for the prognosis of retinoblastoma. Because very little is known about the structure and function of ESD, we determined the 3-dimensional structure of the enzyme at 1.5 {angstrom} resolution using X-ray crystallography. ESD shows a single domain with an {alpha}/{beta}-hydrolase fold. A number of insertions are observed in the canonical {alpha}/{beta}-hydrolase fold. The active site is located in a positively charged, shallow cleft on the surface lined by a number of aromatic residues. Superimposition studies helped identify the typical catalytic triad residues -- Ser-153, His264, and Asp230 -- involved in catalysis. Mutagenesis of any of the catalytic triad residues to alanine abolished the enzyme activity. Backbone amides of Leu54 and Met150 are involved in the formation of the oxyanion hole. Interestingly, a M150A mutation increased the enzyme activity by 62%. The structure of human ESD determined in this study will aid the elucidation of the physiological role of the enzyme in the human body and will assist in the early diagnosis of retinoblastoma. Wu, D., Li, Y., Song, G., Zhang, D., Shaw, N., Liu, Z. J. Crystal structure of human esterase D: a potential genetic marker of retinoblastoma.

36 MATERIALS SCIENCE↗

Improvement of the intrinsic time resolving power of the Cologne iron-free orange type electron spectrometers

Conversion electron spectroscopy represents an important tool for nuclear structure analysis of medium and heavy nuclei. Two iron-free magnetic electron spectrometers of the orange type have been installed at the Institute for Nuclear Physics of the University of Cologne. The very large transmission of 15% and the very good energy resolution of 1% makes the iron-free orange spectrometer a powerful instrument. By means of fast timing techniques, lifetimes of nuclear excited states can be measured with an accuracy better than 20 ps. For the first time, the energy dependent centroid position of prompt events yielding the time-walk characteristics (the prompt curve) of the orange spectrometer fast timing setup has been measured using prompt secondary {delta}-electrons generated in a pulsed beam experiment. The prompt curve calibrated as a function of energy allows precise lifetime determination down to a few tens of picoseconds by the use of the centroid shift method.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solvent organization in the ultrahigh-resolution crystal structure of crambin at room temperature

Ultrahigh-resolution structures provide unprecedented details about protein dynamics, hydrogen bonding and solvent networks. The reported 0.70 Å, room-temperature crystal structure of crambin is the highest-resolution ambient-temperature structure of a protein achieved to date. Sufficient data were collected to enable unrestrained refinement of the protein and associated solvent networks using SHELXL . Dynamic solvent networks resulting from alternative side-chain conformations and shifts in water positions are revealed, demonstrating that polypeptide flexibility and formation of clathrate-type structures at hydrophobic surfaces are the key features endowing crambin crystals with extraordinary diffraction power.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High spatial resolution imaging of biological tissues using nanospray desorption electrospray ionization mass spectrometry

Mass spectrometry imaging (MSI) enables label-free spatial mapping of hundreds of biomolecules in tissue sections. This capability provides valuable information on tissue heterogeneity that is difficult to obtain using population-averaged assays. Despite substantial developments in both instrumentation and methodology, MSI of tissue samples at single-cell resolution remains challenging. In our research, we describe a protocol for robust imaging of tissue sections with a high (better than 10-μm) spatial resolution using nanospray desorption electrospray ionization (nano-DESI) mass spectrometry, an ambient ionization technique that does not require sample pretreatment before analysis. In this protocol, mouse uterine tissue is used as a model system to illustrate both the workflow and data obtained in these experiments. We provide a detailed description of the nano-DESI MSI platform, fabrication of the nano-DESI and shear force probes, shear force microscopy experiments, spectral acquisition, and data processing. A properly trained researcher (e.g., technician, graduate student, or postdoc) can complete all the steps from probe fabrication to data acquisition and processing within a single day. We further describe a new strategy for acquiring both positive- and negative-mode imaging data in the same experiment. This is achieved by alternating between positive and negative data acquisition modes during consecutive line scans. Using our imaging approach, hundreds of high-quality ion images were obtained from a single uterine section. This protocol enables sensitive and quantitative imaging of lipids and metabolites in heterogeneous tissue sections with high spatial resolution, which is critical to understanding biochemical processes occurring in biological tissues.

59 BASIC BIOLOGICAL SCIENCES↗

Structure and Function of the PLAA/Ufd3-p97/Cdc48 Complex

PLAA (ortholog of yeast Doa1/Ufd3, also know as human PLAP or phospholipase A2-activating protein) has been implicated in a variety of disparate biological processes that involve the ubiquitin system. It is linked to the maintenance of ubiquitin levels, but the mechanism by which it accomplishes this is unclear. The C-terminal PUL (PLAP, Ufd3p, and Lub1p) domain of PLAA binds p97, an AAA ATPase, which among other functions helps transfer ubiquitinated proteins to the proteasome for degradation. In yeast, loss of Doa1 is suppressed by altering p97/Cdc48 function indicating that physical interaction between PLAA and p97 is functionally important. Although the overall regions of interaction between these proteins are known, the structural basis has been unavailable. We solved the high resolution crystal structure of the p97-PLAA complex showing that the PUL domain forms a 6-mer Armadillo-containing domain. Its N-terminal extension folds back onto the inner curvature forming a deep ridge that is positively charged with residues that are phylogenetically conserved. The C terminus of p97 binds in this ridge, where the side chain of p97-Tyr805, implicated in phosphorylation-dependent regulation, is buried. Expressed in doa1{Delta} null cells, point mutants of the yeast ortholog Doa1 that disrupt this interaction display slightly reduced ubiquitin levels, but unlike doa1{Delta} null cells, showed only some of the growth phenotypes. These data suggest that the p97-PLAA interaction is important for a subset of PLAA-dependent biological processes and provides a framework to better understand the role of these complex molecules in the ubiquitin system.

36 MATERIALS SCIENCE↗

Masking a CCD camera allows multichord charge exchange spectroscopy measurements at high speed on the DIII-D tokamak

Charge exchange spectroscopy is one of the standard plasma diagnostic techniques used in tokamak research to determine ion temperature, rotation speed, particle density, and radial electric field. Configuring a charge coupled device (CCD) camera to serve as a detector in such a system requires a trade-off between the competing desires to detect light from as many independent spatial views as possible while still obtaining the best possible time resolution. High time resolution is essential, for example, for studying transient phenomena such as edge localized modes. By installing a mask in front of a camera with a 1024 x 1024 pixel CCD chip, we are able to acquire spectra from eight separate views while still achieving a minimum time resolution of 0.2 ms. The mask separates the light from the eight spectra, preventing spatial and temporal cross talk. A key part of the design was devising a compact translation stage which attaches to the front of the camera and allows adjustment of the position of the mask openings relative to the CCD surface. The stage is thin enough to fit into the restricted space between the CCD camera and the spectrometer endplate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗