Search NASA⌕ Search

SEARCH · Search NASA

Results for “Protection & Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Nuclear Safety [Vol. 35, No. 2, July-December 1994]

Nuclear Safety is a journal that covers significant issues in the field of nuclear safety. Its primary scope is safety in the design, construction, operation, and decommissioning of nuclear power reactors worldwide and the research and analysis activities that promote this goal, but it also encompasses the safety aspects of the entire nuclear fuel cycle, including fuel fabrication, spent-fuel processing and handling, and nuclear waste disposal, the handling of fissionable materials and radioisotopes, and the environmental effects of all these activities. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 179 Consideration of Postaccident Consequences in the Determination of Safety Objectives for Future Nuclear Power Plants in France, D. Queniart, A. Sugier, and J. Lochard; ACCIDENT ANALYSIS: 187 Nuclear Safety Research: The Phebus FP Severe Accident Experimental Program, P. von der Hardt, A. V. Jones, C. Lecomte, and A. Tattegrain; 205 Containment Performance Analysis of the Advanced Neutron Source Reactor at the Oak Ridge National Laboratory, S. H. Kim, R. P. Taleyarkhan, and V. Georgevich; 213 Assessment of Fission Product Deposits in the Reactor Coolant System: The DEVAP Program, G. Le Marois and M. Megnin; 222 Erratum to “A Review of the Available Information on the Triggering Stage of a Steam Explosion," Vol. 35, No. 1, CONTROL AND INSTRUMENTATION: 223 Effects of Normal Aging on Calibration and Response Time of Nuclear Plant Resistance Temperature Detectors and Pressure Sensors, H. M. Hashemian; DESIGN FEATURES: 235 Defense in Depth Against the Hydrogen Risk—A European Research Program, F. Fineschi; ENVIRONMENTAL EFFECTS: 246 Technical Note: A Preliminary Analysis of the Risks to Hong Kong Resulting from Potential Accidents of Daya Bay Nuclear Power Plant, Z. Shi and X. Wei; OPERATING EXPERIENCES: 253 Reactor Shutdown Experience, Compiled by J. W. Cletcher; SPECIAL SECTION ON TMI-2 VESSEL INVESTIGATION PROJECT: 256 Three Mile Island—New Findings 15 Years After the Accident A. M. Rubin and E. Beckjord; 269 Relocation of Molten Material to the TMI-2 Lower Head, J. R. Wolf, D. W. Akers, and L. A. Neimark; 280 Insight Into the TMI-2 Core Material Relocation Through Examination of Instrument Tube Nozzles, L. A. Neimark; 288 Physical and Radiochemical Examinations of Debris from the TMI-2 Lower Head, D. W. Akers and B. K. Schuetz; 301 Results of Metallographic Examinations and Mechanical Tests of Pressure Vessel Samples from the TMI-2 Lower Head, D. R. Diercks and G. E. Korth; 313 Margin-to-Failure Calculations for the TMI-2 Vessel, J. Rempe, L. Stickler, S. Chavez, G. Thinnes, R. Witt, and M. Corradini; U.S. NUCLEAR REGULATORY COMMISSION INFORMATION AND ANALYSES: 328 1993 Accident Sequence Precursor (ASP) Program Results, L. N. Vanden Heuvel, J. W. Cletcher, D. A. Copinger, J. W. Minarick, B. W. Dolan, and P. D. O’Reilley; RECENT DEVELOPMENTS: 339 Reports, Standards, and Safety Guides, D. S. Queener; 345 Proposed Rule Changes as of June 30, 1994; ANNOUNCEMENTS: 234 Thirty-First Annual Meeting of the National Council on Radiation Protection and Measurements; 356 1995 International Incineration Conference; 358 Fifth International Controls and Instrumentation Conference; 359 ANS International Topical Meeting on Safety of Operating Reactors; 359 Fifth International Conference on Nuclear Criticality Safety; 360 International Conference on Probabilistic Safety Assessment Methodology and Applications; 351 The Authors; 357 Reviewers of Nuclear Safety, Vol. 35.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Do Piperonyl Butoxide Long-Lasting Insecticide Treated Nets Provide Additional Protection Against Malaria Infections Compared with Conventional Nets in an Operational Setting in Western Kenya?

Malaria control in sub-Saharan Africa has stagnated despite widespread adoption of control measures such as long-lasting insecticidal nets (LLINs). Progress has stalled, in part, because of pyrethroid insecticide resistance, driving the need for retooling to increase the effectiveness of bed nets. Consequently, LLINs have been treated with the chemical synergist piperonyl butoxide (PBO). Piperonyl butoxide LLINs have been shown to be efficacious in controlled settings; however, their effectiveness in real-world settings warrants investigation. In Bungoma County, Western Kenya, a cohort of 768 participants was followed from June 2017 to December 2023 via active and passive surveillance. Household visits were conducted monthly, during which LLIN use for nets distributed in 2017 and 2021 was recorded, and symptomatic malaria cases were identified using rapid diagnostic tests (RDTs). The comparative effectiveness of PBO versus conventional LLINs was assessed in terms of malaria infections. A multilevel logistic regression model was fit with monthly RDT results as the dependent variable. The study results indicate that PBO LLINs provide greater protection against malaria at the individual level than conventional LLINs (odds ratio: 0.70; 95% CI: 0.47–1.03), although the findings were not statistically significant. The added protection against malaria infections provided by PBO LLINs compared with conventional LLINs observed in the current study aligns with findings from most previous studies, although this finding was not statistically significant. In areas with documented pyrethroid resistance, the use of LLINs with an added synergist, such as PBO, can provide additional protection against malaria infections (compared with pyrethroid-only LLINs) and should be considered for scaled-up scenarios despite the additional cost.

60 APPLIED LIFE SCIENCES↗

Effect of Passive Administration of Monoclonal Antibodies Recognizing Simian Immunodeficiency Virus (SIV) V2 in CH59-Like Coil/Helical or β -Sheet Conformations on Time of SIV mac251 Acquisition

The monoclonal antibodies (MAbs) NCI05 and NCI09, isolated from a vacci nated macaque that was protected from multiple simian immunodeficiency virus (SIV) chal lenges, both target an overlapping, conformationally dynamic epitope in SIV envelope vari able region 2 (V2). Here, we show that NCI05 recognizes a CH59-like coil/helical epitope, whereas NCI09 recognizes a b-hairpin linear epitope. In vitro, NCI05 and, to a lesser extent, NCI09 mediate the killing of SIV-infected cells in a CD4-dependent manner. Compared to NCI05, NCI09 mediates higher titers of antibody-dependent cellular cytotoxicity (ADCC) to gp120-coated cells, as well as higher levels of trogocytosis, a monocyte function that contributes to immune evasion. We also found that passive administration of NCI05 or NCI09 to macaques did not affect the risk of SIV mac251 acquisition compared to controls, demonstrating that these anti-V2 antibodies alone are not protective. However, NCI05 but not NCI09 mucosal levels strongly correlated with delayed SIV mac251 acquisition, and functional and structural data suggest that NCI05 targets a transient state of the viral spike apex that is partially opened, compared to its prefusion-closed conformation.

60 APPLIED LIFE SCIENCES↗

Memory protection

Accidental overwriting of files or of memory regions belonging to other programs, browsing of personal files by superusers, Trojan horses, and viruses are examples of breakdowns in workstations and personal computers that would be significantly reduced by memory protection. Memory protection is the capability of an operating system and supporting hardware to delimit segments of memory, to control whether segments can be read from or written into, and to confine accesses of a program to its segments alone. The absence of memory protection in many operating systems today is the result of a bias toward a narrow definition of performance as maximum instruction-execution rate. A broader definition, including the time to get the job done, makes clear that cost of recovery from memory interference errors reduces expected performance. The mechanisms of memory protection are well understood, powerful, efficient, and elegant. They add to performance in the broad sense without reducing instruction execution rate.

Denning, Peter J.↗

Engineering Considerations for Remote Refabrication of EBR-II Fuel Elements

The development of remote controlled methods for manufacturing EBR-II fuel elements was influenced by many interacting factors. Radiation levels within the process cell have been predicted to range from 10 3 to 10 7 rad per hour. Radiation damage to organic lubricant, electrical insulations, elastic seals, and protective coatings precludes the use of many standard machine components. Heat generated in the fuel by absorbed radiation makes forced cooling necessary in many operations. Oxygen must be exluded from all operations where the fuel is exposed. Equipment must be designed for remote maintenance and component replacement within the limitation of available manipulators. The EBR-II fuel consisted of fissium alloy pins sodium bonded in stainless steel tubes. Precision casting was chosen as the basis for refabricating the fuel pins. Remote controlled equipment was developed to cast, assemble, and inspect the EBR-II fuel elements. Radiation resistant, plug-in machine components were developed to give reasonable life expectancy and to allow remote maintenance and replacement.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Solutions Network Formulation Report. NASA's Potential Contributions for Using Solar Ultraviolet Radiation in Conjunction with Photocatalysis for Urban Air Pollution Mitigation and Increasing Air Quality

This Candidate Solution is based on using NASA Earth science research on atmospheric ozone and aerosols data as a means to predict and evaluate the effectiveness of photocatalytically created surfaces (building materials like glass, tile and cement) for air pollution mitigation purposes. When these surfaces are exposed to near UV light, organic molecules, like air pollutants and smog precursors, will degrade into environmentally friendly compounds. U.S. EPA (Environmental Protection Agency) is responsible for forecasting daily air quality by using the Air Quality Index (AQI) that is provided by AIRNow. EPA is partnered with AIRNow and is responsible for calculating the AQI for five major air pollutants that are regulated by the Clean Air Act. In this Solution, UV irradiance data acquired from the satellite mission Aura and the OMI Surface UV algorithm will be used to help understand both the efficacy and efficiency of the photocatalytic decomposition process these surfaces facilitate, and their ability to reduce air pollutants. Prediction models that estimate photocatalytic function do not exist. NASA UV irradiance data will enable this capability, so that air quality agencies that are run by state and local officials can develop and implement programs that utilize photocatalysis for urban air pollution control and, enable them to make effective decisions about air pollution protection programs.

Underwood, Lauren↗

Role of emission controls in reducing the 2050 climate change penalty for PM2.5 in China

Previous studies demonstrated that global warming can lead to deteriorated air quality even when anthropogenic emissions were kept constant, which has been called a climate change penalty on air quality. It is expected that anthropogenic emissions will decrease significantly in the future considering the aggressive emission control actions in China. However, the dependence of climate change penalty on the choice of emission scenario is still uncertain. To fill this gap, we conducted multiple independent model simulations to investigate the response of PM2.5 to future (2050) climate warming (RCP8.5) in China but with different emission scenarios, including the constant 2015 emissions, the 2050 CLE emissions (based on Current Legislation), and the 2050 MTFR emissions (based on Maximum Technically Feasible Reduction). For each set of emissions, we estimate climate change penalty as the difference in PM2.5 between a pair of simulations with either 2015 or 2050 meteorology. Under 2015 emissions, we find a PM2.5 climate change penalty of 1.43 μg m−3 in Eastern China, leading to an additional 35,000 PM2.5-related premature deaths [95% confidence interval (CI), 21,000-40,000] by 2050. However, the PM2.5 climate change penalty weakens to 0.24 μg m−3 with strict anthropogenic emission controls under the 2050 MTFR emissions, which decreases the associated PM2.5-related deaths to 17,000. The smaller MTFR climate change penalty contributes 14% of the total PM2.5 decrease when both emissions and meteorology are changed from 2015 to 2050, and 24% of total health benefits associated with this PM2.5 decrease in Eastern China. This finding suggests that controlling anthropogenic emissions can effectively reduce the climate change penalty on PM2.5 and its associated premature deaths, even though a climate change penalty still occurs even under MTFR. Strengthened controls on anthropogenic emissions are key to attaining air quality targets and protecting human health in the context of future global climate change.

Emission controls↗

Arc discharge supply component protection circuitry

In a mercury-bombardment ion engine, the discharge supply is a high-current low-voltage one that maintains an arc or discharge inside the engine. In a 30-cm engine the supply provides up to 45 volts at about 13 amperes and is referenced at approximately 1100 volts above ground. Due to the engine discharge characteristics, a very slow feedback control loop is required. A high-speed current limit must be used to protect the components in the power conditioner, a pulse-width-modulated bridge inverter. A high-speed cycle-by-cycle current-limit circuit which allows the inverter to continue running in an overcurrent condition is used to protect it. The high-speed current sensing allows the inverter to be turned off each half cycle before the current in the primary of the inverter exceeds a safe level. This permits the inverter to continue to provide current into a discharge or a fault condition, until the feedback control system can actively control the current.

Ahrens, A. F.↗

Feasibility study of aileron and spoiler control systems for large horizontal axis wind turbines

The feasibility of using aileron or spoiler controls as alternates to pitch control for large horizontal axis wind turbines was studied. The NASA Mod-0 100 kw machine was used as the basis for the study. Specific performance studies were conducted for 20% chord ailerons over the outboard 30% span, and for 10% chord spoilers over the same portion of the span. Both control systems utilized control deflections up to 60 deg. Results of the study show that either ailerons or spoilers can provide the control necessary to limit turbine power in high wind conditions. The aileron system, as designed, provides overspeed protection at hurricane wind speeds, low wind speed starting torque of 778 N-m (574 ft. lb) at 3.6 m/sec, and a 1.3 to 1.5% increase in annual energy compared to a fixed pitch rotor. The aileron control system preliminary design study includes aileron loads analysis and the design of a failsafe flyweight actuator for overspeed protection in the event of a hydraulic system failure.

Wentz, W. H., Jr.↗

Access Control of Web- and Java-Based Applications

Cybersecurity has become a great concern as threats of service interruption, unauthorized access, stealing and altering of information, and spreading of viruses have become more prevalent and serious. Application layer access control of applications is a critical component in the overall security solution that also includes encryption, firewalls, virtual private networks, antivirus, and intrusion detection. An access control solution, based on an open-source access manager augmented with custom software components, was developed to provide protection to both Web-based and Javabased client and server applications. The DISA Security Service (DISA-SS) provides common access control capabilities for AMMOS software applications through a set of application programming interfaces (APIs) and network- accessible security services for authentication, single sign-on, authorization checking, and authorization policy management. The OpenAM access management technology designed for Web applications can be extended to meet the needs of Java thick clients and stand alone servers that are commonly used in the JPL AMMOS environment. The DISA-SS reusable components have greatly reduced the effort for each AMMOS subsystem to develop its own access control strategy. The novelty of this work is that it leverages an open-source access management product that was designed for Webbased applications to provide access control for Java thick clients and Java standalone servers. Thick clients and standalone servers are still commonly used in businesses and government, especially for applications that require rich graphical user interfaces and high-performance visualization that cannot be met by thin clients running on Web browsers

Tso, Kam S.↗

Lower Three Runs Remediation Safety Preparation Strategy - 13318

The Savannah River Site (SRS) is a 310-square-mile United States Department of Energy (US DOE) nuclear facility located along the Savannah River near Aiken, South Carolina that contains six primary stream/river systems. The Lower Three Runs Stream (LTR) is one of the primary streams within the site that is located in the southeast portion of the Savannah River Site. It is a large blackwater stream system that originates in the northeast portion of SRS and follows a southerly direction before it enters the Savannah River. During reactor operations, secondary reactor cooling water, storm sewer discharges, and miscellaneous wastewater was discharged and contaminated a 20 mile stretch of Lower Three Runs Stream that narrows and provides a limited buffer of US DOE property along the stream and flood-plain. Based on data collected during the years 2009 and 2010 under American Recovery and Re-investment Act funding, the stream was determined to be contaminated with cesium-137 at levels that exceeded acceptable risk based limits. In agreement with the Environmental Protection Agency and the South Carolina Department of Health and Environmental Control, three areas were identified for remediation [1] (SRNS April 2012). A comprehensive safety preparation strategy was developed for safe execution of the LTR remediation project. Contract incentives for safety encouraged the contractor to perform a complete evaluation of the work and develop an implementation plan to perform the work. The safety coverage was controlled to ensure all work was observed and assessed by one person per work area within the project. This was necessary due to the distances between the fence work and three transects being worked, approximately 20 miles. Contractor Management field observations were performed along with DOE assessments to ensure contractor focus on safe performance of the work. Dedicated ambulance coverage for remote worker work activities was provided. This effort was augmented with access to medical evacuation services. The areas where the work was performed were remote and difficult to get emergency vehicles to in a timely manner in case of an accident. Satellite phones were utilized due to intermittent phone coverage. High visibility vests were utilized to enable any hunters in the area to see the workers; due to the limited buffer areas along the stream route. An innovative approach to providing the necessary protection for workers during periods of extreme heat and humidity was also employed, which included the use of 'heat islands' with fans and crew trailers and ice vests for workers. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Controlling topology through targeted composite symmetry manipulation in magnetic systems

The possibility of selecting magnetic space groups by orienting the magnetization direction or tuning magnetic orders offers a vast playground for engineering symmetry-protected topological phases in magnetic materials. In this work, we study how selective tuning of symmetry and magnetism can influence and control the resulting topology in a two-dimensional magnetic system, and we illustrate such a procedure in the ferromagnetic monolayer MnPSe 3 . Density functional theory calculations reveal a symmetry-protected accidental semimetallic (SM) phase for out-of-plane magnetization, which becomes an insulator when the magnetization is tilted in-plane, reaching band-gap values close to 100 meV. We identify an order-2 composite antiunitary symmetry and threefold rotational symmetry that induce the band crossing, and we classify the possible topological phases using symmetry analysis, which we support with tight-binding and k · p models. Breaking of inversion symmetry opens a gap in the SM phase, giving rise to a Chern insulator. We demonstrate this explicitly in the isostructural Janus compound Mn 2 ⁢P 2 ⁢S 3 ⁢Se 3 , which naturally exhibits Rashba spin-orbit coupling that breaks inversion symmetry. Our results map out the phase space of topological properties of ferromagnetic transition-metal phosphorus trichalcogenides, and they demonstrate the potential of the magnetization-dependent metal-to-insulator transition as a spin switch in integrated two-dimensional electronics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Radiation Protection for the First Korea Heavy-ion Medical Accelerator (KHIMA) Facility - Paper 7

The number of particle therapy facilities is increasing worldwide due to the encouraging results obtained at research facilities such as the Lawrence Berkeley National Laboratory (USA), the Helmholtz Center for Heavy Ion Research GSI (Germany), and the Heavy Ion Medical Accelerator (HIMAC) in Chiba (Japan). The first hospital-based heavy-ion therapy facility is under construction in Busan, Korea, at the Korea Institute of Radiological and Medical Sciences [KIRAMS]. The project was originally designed to develop a compact superconducting cyclotron for hadron therapy able to deliver forefront beams of heavier ions, essentially carbon ions of energy, 430 MeV/u. Radiation protection issues play an important role in every stage of the project such as civil construction planning, control system design, and special technological plants. Monte Carlo transport codes are the best tools to solve these issues and the FLUKA2011 and MCNPX2.7.0 codes are used in this work. Beam loss distributions of cyclotron installations in combination with passive or active beam shaping methods have a particularly high implication on the protection layout of the facility. Methods for shielding and activation calculations are described with an emphasis on carbon ion beams. All the tools and databases require verification. Benchmarking is an instrumental process for verification. An overview of benchmarking efforts will also be given and the need for further benchmarks is discussed. (authors)

43 PARTICLE ACCELERATORS↗

Prototype Motor Controllers Demonstrated for the James Webb Space Telescope Cryogenic Environment

NASA is in the process of designing the James Webb Space Telescope. This telescope will investigate images of objects in deep space (stars, galaxies, etc.) by using light in the infrared region of the light spectrum. To make such observations, the telescope must have light sensors that operate at very cold temperatures, near absolute zero. To achieve this low-temperature tolerance, designers must place the light sensors behind a Sun shield that will prevent sunlight, and its heat, from reaching the sensors. In this cold region inside the telescope, electric motors and some motor controls must operate at temperatures near 40 K (40 degrees above absolute zero). These motors will be used to position light filters needed by the telescope. There are motors that operate at the low temperatures, but there is little technology for low-temperature motor-control electronics. The drawing shows how the motors and their controls are positioned behind the Sun shield. Simplified version of the layout of the motor and control electronics that are located, as dictated by mission requirements, in the cold zone of the James Webb Space Telescope. A Sun shield provides protection and isolation of these electronics from the heat of the rays of the sun. Room temperature compoenets (control computer, motor select command, motor phase drive, power supply, parallel to serial, and sun shield) as well as 40-kelvin components (motor select, serial to parallel, and motors) are shown. The Low Temperature Electronics Group at the NASA Glenn Research Center has been working to develop motor control electronics that will operate at a temperature of 40 K. The group conducted tests to determine which electronic components will operate at such very low temperatures. Then, components that were determined to operate successfully at the low temperatures were used to design low-temperature motor-controller circuits. A prototype motor controller circuit was built, evaluated, and demonstrated to operate at 70 K. Next, Glenn researchers plan to determine circuit performance at much colder temperatures--down to 40 K. This low-temperature program was supported by the James Webb Space Telescope Electrical Systems Design Group at the NASA Goddard Space Flight Center and by the NASA Electronic Parts and Packaging Program at NASA Headquarters and the Jet Propulsion Laboratory.

Patterson, Richard L.↗

Approaches for effective negative pressure isolation space control to minimize airborne transmission of contaminants in residential homes

Controlling airborne transmission of contaminants including respired viruses such as SARS-CoV-2 is necessary to protect occupants living in the same house with a contagious person. The effectiveness of interventions requiring minor efforts that create a negative pressure isolation zone (IZ) for a contagious person has yet to be systematically tested for residential homes. In this study, ASHRAE Standard 170, which offers guidance for negative pressure isolation space control in healthcare facilities, was used in developing practical and attainable recommendations for residential single-family homes. The relative effectiveness of several control strategies was evaluated through experimentally conducting 17 different test cases in a manufactured single-family house laboratory. These cases were designed based on various heating, ventilation and air-conditioning (HVAC) operating scenarios, intervention measures including closing the IZ door and/or sealing over supply and return air grilles in the IZ, and utilization of bathroom exhaust or portable window fans for pressure control. Four out of 17 test cases were identified as having the potential for strong containment with adequate depressurization in the IZ. The most effective IZ depressurization was achieved through continuously operating the exhaust fan in the bathroom attached to the IZ, by installing a portable window fan that extracted air out of the IZ, and a portable room air conditioner with the AC unit exhaust duct installed in one of the IZ windows.

Construction & Building Technology↗

An Historic Perspective of NPDES Individual Permit for Storm Water Discharges from Solid Waste Management Units at Los Alamos National Laboratory - 18667

The Los Alamos National Laboratory (LANL) and the associated communities of Los Alamos and White Rock are located in Los Alamos County in north-central New Mexico approximately 60 mi north-northeast of Albuquerque and 25 mi northwest of Santa Fe. The 36-mi{sup 2} facility is situated on the Pajarito Plateau, which consists of a series of fingerlike mesas separated by deep east-to-west oriented canyons cut by predominately ephemeral and intermittent streams. The mesa tops range in elevation from approximately 7800 ft. on the flanks of the Jemez Mountains to about 6200 ft. at their eastern termination above the Rio Grande Canyon. The land surrounding the Laboratory is largely undeveloped. Public access to much of the facility is limited for safety and security reasons. Large tracts of surrounding land are held by the U.S. Forest Service (Santa Fe National Forest), the Bureau of Land Management (Bandelier National Monument), the General Services Administration and San Ildefonso Pueblo. Storm water discharges from Solid Waste Management Units (SWMUs) have been regulated at the LANL since the early 1990's and have evolved into an Individual Stormwater Permit (IP) that may be one of the most complex in the nation. Historically, storm water discharges from SWMUs at LANL were regulated under a nationwide general permit using a watershed based approach requiring a Storm Water Pollution Prevention Plan (SWPPP), monitoring at sub-watershed scale 'USGS like' gage stations, and inspection and maintenance of erosion controls. In 2001, the Cerro Grande Fire destroyed many Laboratory structures, residential homes and over 80,000 acres of forested lands in the upper watershed above Los Alamos that significantly changed the local hydrology. Several years later, a Federal Facilities Compliance Agreement (FFCA) was issued by U.S. Environmental Protection Agency (USEPA) that was followed by a Clean Water Act lawsuit filed by concerned citizens, the result of which required more focus on stormwater discharges from individual SWMUs and an IP covering over 400 Sites. The IP contains non-numeric technology-based effluent limitations, coupled with a comprehensive, coordinated inspection and monitoring program, to minimize pollutants in LANL's storm water discharges associated with historical industrial activities from specified Sites. Non-numeric technology-based effluent limitations include minimizing pollutants in discharges through erosion and sedimentation controls, management of run-on and runoff, employee training, inspection and maintenance of controls, annual reporting and public involvement. The IP establishes Target Action Levels (TALs) that are equivalent to New Mexico State water-quality criteria. These TALs are used as benchmarks to determine the effectiveness of control measures implemented under the IP. That is, storm water quality sample results from SWMU discharges are compared with applicable TALs. If one or more sample results exceed a TAL, LANL must take additional corrective action. The TAL results are also confounded by high levels of naturally occurring constituents such as aluminum and gross alpha, and urban constituents such as copper, zinc and PCBs which may not be a source from the regulated SWMU. Due to the remote rugged terrain, security access issues, number of monitoring locations, stringent TALs, reporting requirements and public involvement requirements, this permit is likely one of the most stringent and complex in the country. The Laboratory has implemented this permit in a compliant manner for the past seven years and is anticipating the issuance of a new permit in the next few months. This paper will cover permit requirements related to control measure installations, monitoring, reporting and public involvement as well as process improvements and remaining water quality initiatives such as developing studies to address issues such as discriminating between natural background levels and LANL-related contaminants during the execution of this unique permit. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Viability of Cathodic Protection for Preventing Corrosion of Stainless Steel 316H in Molten LiF-NaF-KF

Molten fluoride salts are candidate heat transfer fluids in a number of applications such as generation IV molten salt nuclear reactors and concentrated solar power plants. However, a chief concern in the design of these systems is the corrosion of structural materials that come in contact with these molten salts. Redox control methods such as the purification of salt, the addition of active elements, and applied electrochemical potential can be efficient methods for preventing the corrosion of structural materials in molten fluoride salts. Applied electrochemical potential as a redox control method for application in molten fluoride salts has rarely been explored. This study seeks to understand the viability of impressed current cathodic protection (CP) at various currents as a redox control method to prevent corrosion of stainless steel 316H in molten LiF-NaF-KF (FLiNaK) salt. Results show that application of CP can be an effective method to prevent corrosion of SS316H in molten FLiNaK salt, but the applied current will have to be optimized to prevent undesirable side effects such as reduction of salt constituents, salt deposition on electrodes, etc.

Materials Science↗

SU-E-T-136: Assessment of Seasonal Linear Accelerator Output Variations and Associated Impacts

Purpose: Application of process control theory in quality assurance programs promises to allow earlier identification of problems and potentially better quality in delivery than traditional paradigms based primarily on tolerances and action levels. The purpose of this project was to characterize underlying seasonal variations in linear accelerator output that can be used to improve performance or trigger preemptive maintenance. Methods: Review of runtime plots of daily (6 MV) output data acquired using in house ion chamber based devices over three years and for fifteen linear accelerators of varying make and model were evaluated. Shifts in output due to known interventions with the machines were subtracted from the data to model an uncorrected scenario for each linear accelerator. Observable linear trends were also removed from the data prior to evaluation of periodic variations. Results: Runtime plots of output revealed sinusoidal, seasonal variations that were consistent across all units, irrespective of manufacturer, model or age of machine. The average amplitude of the variation was on the order of 1%. Peak and minimum variations were found to correspond to early April and September, respectively. Approximately 48% of output adjustments made over the period examined were potentially avoidable if baseline levels had corresponded to the mean output, rather than to points near a peak or valley. Linear trends were observed for three of the fifteen units, with annual increases in output ranging from 2–3%. Conclusion: Characterization of cyclical seasonal trends allows for better separation of potentially innate accelerator behaviour from other behaviours (e.g. linear trends) that may be better described as true out of control states (i.e. non-stochastic deviations from otherwise expected behavior) and could indicate service requirements. Results also pointed to an optimal setpoint for accelerators such that output of machines is maintained within set tolerances and interventions are required less frequently.

07 ISOTOPE AND RADIATION SOURCES↗