Search NASA⌕ Search

SEARCH · Search NASA

Results for “Radiator Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

SU-E-I-43: Pediatric CT Dose and Image Quality Optimization

Purpose: To design an approach to optimize radiation dose and image quality for pediatric CT imaging, and to evaluate expected performance. Methods: A methodology was designed to quantify relative image quality as a function of CT image acquisition parameters. Image contrast and image noise were used to indicate expected conspicuity of objects, and a wide-cone system was used to minimize scan time for motion avoidance. A decision framework was designed to select acquisition parameters as a weighted combination of image quality and dose. Phantom tests were used to acquire images at multiple techniques to demonstrate expected contrast, noise and dose. Anthropomorphic phantoms with contrast inserts were imaged on a 160mm CT system with tube voltage capabilities as low as 70kVp. Previously acquired clinical images were used in conjunction with simulation tools to emulate images at different tube voltages and currents to assess human observer preferences. Results: Examination of image contrast, noise, dose and tube/generator capabilities indicates a clinical task and object-size dependent optimization. Phantom experiments confirm that system modeling can be used to achieve the desired image quality and noise performance. Observer studies indicate that clinical utilization of this optimization requires a modified approach to achieve the desired performance. Conclusion: This work indicates the potential to optimize radiation dose and image quality for pediatric CT imaging. In addition, the methodology can be used in an automated parameter selection feature that can suggest techniques given a limited number of user inputs. G Stevens and R Singh are employees of GE Healthcare.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mechanistic understanding of zirconium alloy fuel cladding Performance - 2016-0095

A review is presented of work performed in our group over the years in the areas of radiation damage, corrosion, hydrogen pickup, hydriding, and the mechanical behavior of zirconium alloy nuclear fuel cladding with the goal of developing a greater mechanistic understanding of cladding performance in service. (authors)

36 MATERIALS SCIENCE↗

Compendium of Material Composition Data for Radiation Transport Modeling

Introduction Meaningful simulations of radiation transport applications require realistic definitions of material composition and densities. When seeking that information for applications in fields such as homeland security, radiation shielding and protection, and criticality safety, researchers usually encounter a variety of materials for which elemental compositions are not readily available or densities are not defined. Publication of the Compendium of Material Composition Data for Radiation Transport Modeling, Revision 0, in 2006 was the first step toward mitigating this problem. Revision 0 of this document listed 121 materials, selected mostly from the combined personal libraries of staff at the Pacific Northwest National Laboratory (PNNL), and thus had a scope that was recognized at the time to be limited. Nevertheless, its creation did provide a well-referenced source of some unique or hard-to-define material data in a format that could be used directly in radiation transport calculations being performed at PNNL. Moreover, having a single common set of material definitions also helped to standardize at least one aspect of the various modeling efforts across the laboratory by providing separate researchers the ability to compare different model results using a common basis of materials. The authors of the 2006 compendium understood that, depending on its use and feedback, the compendium would need to be revised to correct errors or inconsistencies in the data for the original 121 materials, as well as to increase (per users suggestions) the number of materials listed. This 2010 revision of the compendium has accomplished both of those objectives. The most obvious change is the increased number of materials from 121 to 372. The not-so-obvious change is the mechanism used to produce the data listed here. The data listed in the 2006 document were compiled, evaluated, entered, and error-checked by a group of individuals essentially by hand, providing no library file or mechanism for revising the data in a consistent and traceable manner. The authors of this revision have addressed that problem by first compiling all of the information (i.e., numbers and references) for all the materials into a single database, maintained at PNNL, that was then used as the basis for this document.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

TH-CD-201-12: Preliminary Evaluation of Organic Field Effect Transistors as Radiation Detectors

Purpose: To fabricate organic field effect transistors (OFETs) and evaluate their performance before and after exposure to ionizing radiation. To determine if OFETs have potential to function as radiation dosimeters. Methods: OFETs were fabricated on both Si/SiO{sub 2} wafers and flexible polymer substrates using standard processing techniques. Pentacene was used as the organic semiconductor material and the devices were fabricated in a bottom gate configuration. Devices were irradiated using an orthovoltage treatment unit (120 kVp x-rays). Threshold voltage values were measured with the devices in saturation mode and quantified as a function of cumulative dose. Current-voltage characteristics of the devices were measured using a Keithley 2614 SourceMeter SMU Instrument. The devices were connected to the reader but unpowered during irradiations. Results: Devices fabricated on Si/SiO2 wafers demonstrated excellent linearity (R{sup 2} > 0.997) with threshold voltages that ranged between 15 and 36 V. Devices fabricated on a flexible polymer substrate had substantially smaller threshold voltages (∼ 4 – 8 V) and slightly worse linearity (R{sup 2} > 0.98). The devices demonstrated excellent stability in I–V characteristics over a large number (>2000) cycles. Conclusion: OFETs have demonstrated excellent potential in radiation dosimetry applications. A key advantage of these devices is their composition, which can be substantially more tissue-equivalent at low photon energies relative to many other types of radiation detector. In addition, fabrication of organic electronics can employ techniques that are faster, simpler and cheaper than conventional silicon-based devices. These results support further development of organic electronic devices for radiation detection purposes. Funding Support, Disclosures, and Conflict of Interest: This work was funded by the Natural Sciences and Engineering Research Council of Canada.

60 APPLIED LIFE SCIENCES↗

Infrared properties of z = 7 galaxies from cosmological simulations

Three-dimensional panchromatic dust radiative transfer calculations are performed on a set of 198 galaxies of stellar masses in the range of 5 × 10{sup 8} to 3 × 10{sup 10} M {sub ☉} from a cosmological hydrodynamic simulation (resolved at 29 h {sup –1} pc) at z ∼ 7. In a companion paper, the stellar mass and UV luminosity functions and the UV-optical and FUV-NUV colors are shown to be in good agreement with observations if a Small Magellanic Cloud type dust extinction curve is adopted. Here, we make useful predictions, self-consistently, of the infrared properties of these z ∼ 7 simulated galaxies that can be confronted with upcoming ALMA data. Our findings are as follows. (1) The effective radius in the rest-frame MIPS70 μm band is in the range of 80-400 pc proper for z = 7 galaxies with L {sub FIR} = 10{sup 11.3}-10{sup 12} L {sub ☉}. (2) The median of the peak wavelength of the far-infrared (FIR) spectral energy distribution is in the range of 45-60 μm, depending on the dust-to-metal ratio. (3) For star formation rate in the range of 3-100 M {sub ☉} yr{sup –1}, the median FIR to bolometric luminosity ratio is 60%-90%. (4) The FIR luminosity function displays a power law in the high end with a slope of –3.1 ± 0.4 instead of the usual exponential decline.

79 ASTRONOMY AND ASTROPHYSICS↗

Novel detection methods for radiation-induced electron-hole pairs.

Most common ionizing radiation detectors typically rely on one of two general methods: collection of charge generated by the radiation, or collection of light produced by recombination of excited species. Substantial efforts have been made to improve the performance of materials used in these types of detectors, e.g. to raise the operating temperature, to improve the energy resolution, timing or tracking ability. However, regardless of the material used, all these detectors are limited in performance by statistical variation in the collection efficiency, for charge or photons. We examine three alternative schemes for detecting ionizing radiation that do not rely on traditional direct collection of the carriers or photons produced by the radiation. The first method detects refractive index changes in a resonator structure. The second looks at alternative means to sense the chemical changes caused by radiation on a scintillator-type material. The final method examines the possibilities of sensing the perturbation caused by radiation on the transmission of a RF transmission line structure. Aspects of the feasibility of each approach are examined and recommendations made for further work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Simulations of the effects of water vapor, cloud liquid water, and ice on AMSU moisture channel brightness temperatures

Radiative transfer simulations are performed to determine how water vapor and nonprecipitating cloud liquid water and ice particles within typical midlatitude atmospheres affect brightness temperatures T(sub B)'s of moisture sounding channels used in the Advanced Microwave Sounding Unit (AMSU) and AMSU-like instruments. The purpose is to promote a general understanding of passive top-of-atmosphere T(sub B)'s for window frequencies at 23.8, 89.0, and 157.0 GHz, and water vapor frequencies at 176.31, 180.31, and 182.31 GHz by documenting specific examples. This is accomplished through detailed analyses of T(sub B)'s for idealized atmospheres, mostly representing temperate conditions over land. Cloud effects are considered in terms of five basic properties: droplet size distribution, phase, liquid or ice water content, altitude, and thickness. Effects on T(sub B) of changing surface emissivity also are addressed. The brightness temperature contribution functions are presented as an aid to physically interpreting AMSU T(sub B)'s. Both liquid and ice clouds impact the T(sub B)'s in a variety of ways. The T(sub B)'s at 23.8 and 89 GHz are more strongly affected by altostratus liquid clouds than by cirrus clouds for equivalent water paths. In contrast, channels near 157 and 183 GHz are more strongly affected by ice clouds. Higher clouds have a greater impact on 157- and 183-GHz T(sub B)'s than do lower clouds. Clouds depress T(sub B)'s of the higher-frequency channels by suppressing, but not necessarily obscuring, radiance contributions from below. Thus, T(sub B)'s are less closely associated with cloud-top temperatures than are IR radiometric temperatures. Water vapor alone accounts for up to 89% of the total attenuation by a midtropospheric liquid cloud for channels near 183 GHz. The Rayleigh approximation is found to be adequate for typical droplet size distributions; however, Mie scattering effects from liquid droplets become important for droplet size distribution functions with modal radii greater than 20 micrometers near 157 and 183 GHz, and greater than 30-40 micrometers at 89 GHz. This is due mainly to the relatively small concentrations of droplets much larger than the mode radius. Orographic clouds and tropical cumuli have been observed to contain droplet size distributions with mode radii in the 30-40 micrometers range. Thus, as new instruments bridge the gap between microwave and infrared to frequencies even higher than 183 GHz, radiative transfer modelers are cautioned to explicitly address scattering characteristics of such clouds.

Muller, Bradley M.↗

TU-H-CAMPUS-JeP1-02: Fully Automatic Verification of Automatically Contoured Normal Tissues in the Head and Neck

Purpose: To investigate and validate the use of an independent deformable-based contouring algorithm for automatic verification of auto-contoured structures in the head and neck towards fully automated treatment planning. Methods: Two independent automatic contouring algorithms [(1) Eclipse’s Smart Segmentation followed by pixel-wise majority voting, (2) an in-house multi-atlas based method] were used to create contours of 6 normal structures of 10 head-and-neck patients. After rating by a radiation oncologist, the higher performing algorithm was selected as the primary contouring method, the other used for automatic verification of the primary. To determine the ability of the verification algorithm to detect incorrect contours, contours from the primary method were shifted from 0.5 to 2cm. Using a logit model the structure-specific minimum detectable shift was identified. The models were then applied to a set of twenty different patients and the sensitivity and specificity of the models verified. Results: Per physician rating, the multi-atlas method (4.8/5 point scale, with 3 rated as generally acceptable for planning purposes) was selected as primary and the Eclipse-based method (3.5/5) for verification. Mean distance to agreement and true positive rate were selected as covariates in an optimized logit model. These models, when applied to a group of twenty different patients, indicated that shifts could be detected at 0.5cm (brain), 0.75cm (mandible, cord), 1cm (brainstem, cochlea), or 1.25cm (parotid), with sensitivity and specificity greater than 0.95. If sensitivity and specificity constraints are reduced to 0.9, detectable shifts of mandible and brainstem were reduced by 0.25cm. These shifts represent additional safety margins which might be considered if auto-contours are used for automatic treatment planning without physician review. Conclusion: Automatically contoured structures can be automatically verified. This fully automated process could be used to flag auto-contours for special review or used with safety margins in a fully automatic treatment planning system.

60 APPLIED LIFE SCIENCES↗

Combined-Modality Therapy With Gemcitabine and Radiation Therapy as a Bladder Preservation Strategy: Long-Term Results of a Phase I Trial

Purpose: A Phase I trial of twice-weekly gemcitabine and concurrent radiation therapy (RT) was performed in patients with muscle-invasive bladder cancer. We present the final analysis of bladder-intact survival (BIS), disease-specific survival (DSS), and overall survival (OS). Methods and Materials: Eligible patients had muscle-invasive transitional cell carcinoma (cT2-3) and were candidates for cystectomy. Patients underwent maximal transurethral resection of bladder tumor followed by twice-weekly gemcitabine with concurrent RT to the bladder (total of 60 Gy over 6 weeks). Gemcitabine doses ranged from 10 to 33 mg/m{sup 2}. Results: Median follow-up was 5.6 years (range, 0.6-9.5 years). Twenty-three of 24 patients were evaluable for response. All patients were clinical stage T2. Locoregional failure occurred in seven patients (30%), which were successfully salvaged by radical cystectomy (n = 5) or intravesical therapy (n = 2). Four local failures occurred > 5 years after therapy. Most local failures were noninvasive tumors (Ta or Tis, n = 6). Ten patients (43%) experienced optimal outcome (no failures and bladder intact). The 5-year actuarial estimates of survival are BIS 62%, OS 76%, and DSS 82%. Conclusion: Twice-weekly gemcitabine with concurrent RT is well tolerated and provides rates of survival and bladder preservation that are comparable to the existing literature. All locoregional failures were successfully salvaged by either radical cystectomy or intravesical therapy. Given the high proportion of late local failures, we recommend long-term monitoring when using this regimen. Future studies comparing the safety and efficacy of gemcitabine- vs. platinum-based bladder preservation protocols are pending.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Advanced Multifunctional MMOD Shield: Radiation Shielding Assessment

As NASA is looking to explore further into deep space, multifunctional materials are a necessity for decreasing complexity and mass. One area where multifunctional materials could be extremely beneficial is in the micrometeoroid orbital debris (MMOD) shield. A typical MMOD shield on the International Space Station (ISS) is a stuffed whipple shield consisting of multiple layers. One of those layers is the thermal blanket, or multi-layer insulation (MLI). Increasing the MMOD effectiveness of MLI blankets, while still preserving their thermal capabilities, could allow for a less massive MMOD shield. Thus, a study was conducted to evaluate a concept MLI blanket for an MMOD shield. In conjunction, this MLI blanket and the subsequent MMOD shield was also evaluated for its radiation shielding effectiveness towards protecting crew. The overall MMOD shielding system using the concept MLI blanket proved to only have a marginal increase in the radiation mitigating properties. Therefore, subsequent analysis was performed on various conceptual MMOD shields to determine the combination of materials that may prove superior for radiation mitigating purposes. The following paper outlines the evaluations performed and discusses the results and conclusions of this evaluation for radiation shielding effectiveness.

Rojdev, Kristina↗

JET FORMATION FROM MASSIVE YOUNG STARS: MAGNETOHYDRODYNAMICS VERSUS RADIATION PRESSURE

Observations indicate that outflows from massive young stars are more collimated during their early evolution compared to later stages. Our paper investigates various physical processes that impact the outflow dynamics, i.e., its acceleration and collimation. We perform axisymmetric magnetohydrodynamic (MHD) simulations particularly considering the radiation pressure exerted by the star and the disk. We have modified the PLUTO code to include radiative forces in the line-driving approximation. We launch the outflow from the innermost disk region (r < 50 AU) by magnetocentrifugal acceleration. In order to disentangle MHD effects from radiative forces, we start the simulation in pure MHD and later switch on the radiation force. We perform a parameter study considering different stellar masses (thus luminosity), magnetic flux, and line-force strength. For our reference simulation-assuming a 30 M{sub Sun} star-we find substantial de-collimation of 35% due to radiation forces. The opening angle increases from 20 Degree-Sign to 32 Degree-Sign for stellar masses from 20 M{sub Sun} to 60 M{sub Sun }. A small change in the line-force parameter {alpha} from 0.60 to 0.55 changes the opening angle by {approx}8 Degree-Sign . We find that it is mainly the stellar radiation that affects the jet dynamics. Unless the disk extends very close to the star, its force is too small to have much impact. Essentially, our parameter runs with different stellar masses can be understood as a proxy for the time evolution of the star-outflow system. Thus, we have shown that when the stellar mass (thus luminosity) increases with age, the outflows become less collimated.

79 ASTRONOMY AND ASTROPHYSICS↗

Hydrodynamic simulations of long-scale-length two-plasmon-decay experiments at the Omega Laser Facility

Direct-drive-ignition designs with plastic CH ablators create plasmas of long density scale lengths (L{sub n} {>=} 500 {mu}m) at the quarter-critical density (N{sub qc}) region of the driving laser. The two-plasmon-decay (TPD) instability can exceed its threshold in such long-scale-length plasmas (LSPs). To investigate the scaling of TPD-induced hot electrons to laser intensity and plasma conditions, a series of planar experiments have been conducted at the Omega Laser Facility with 2-ns square pulses at the maximum laser energies available on OMEGA and OMEGA EP. Radiation-hydrodynamic simulations have been performed for these LSP experiments using the two-dimensional hydrocode draco. The simulated hydrodynamic evolution of such long-scale-length plasmas has been validated with the time-resolved full-aperture backscattering and Thomson-scattering measurements. draco simulations for CH ablator indicate that (1) ignition-relevant long-scale-length plasmas of L{sub n} approaching {approx}400 {mu}m have been created; (2) the density scale length at N{sub qc} scales as L{sub n}({mu}m) Asymptotically-Equal-To (R{sub DPP} Multiplication-Sign I{sup 1/4}/2); and (3) the electron temperature T{sub e} at N{sub qc} scales as T{sub e}(keV) Asymptotically-Equal-To 0.95 Multiplication-Sign {radical}(I), with the incident intensity (I) measured in 10{sup 14} W/cm{sup 2} for plasmas created on both OMEGA and OMEGA EP configurations with different-sized (R{sub DPP}) distributed phase plates. These intensity scalings are in good agreement with the self-similar model predictions. The measured conversion fraction of laser energy into hot electrons f{sub hot} is found to have a similar behavior for both configurations: a rapid growth [f{sub hot} Asymptotically-Equal-To f{sub c} Multiplication-Sign (G{sub c}/4){sup 6} for G{sub c} < 4] followed by a saturation of the form, f{sub hot} Asymptotically-Equal-To f{sub c} Multiplication-Sign (G{sub c}/4){sup 1.2} for G{sub c} {>=} 4, with the common wave gain is defined as G{sub c}=3 Multiplication-Sign 10{sup -2} Multiplication-Sign I{sub qc}L{sub n}{lambda}{sub 0}/T{sub e}, where the laser intensity contributing to common-wave gain I{sub qc}, L{sub n}, T{sub e} at N{sub qc}, and the laser wavelength {lambda}{sub 0} are, respectively, measured in [10{sup 14} W/cm{sup 2}], [{mu}m], [keV], and [{mu}m]. The saturation level f{sub c} is observed to be f{sub c} Asymptotically-Equal-To 10{sup -2} at around G{sub c} Asymptotically-Equal-To 4. The hot-electron temperature scales roughly linear with G{sub c}. Furthermore, to mitigate TPD instability in long-scale-length plasmas, different ablator materials such as saran and aluminum have been investigated on OMEGA EP. Hot-electron generation has been reduced by a factor of 3-10 for saran and aluminum plasmas, compared to the CH case at the same incident laser intensity. draco simulations suggest that saran might be a better ablator for direct-drive-ignition designs as it balances TPD mitigation with an acceptable hydro-efficiency.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Refinement, Validation and Application of Cloud-Radiation Parameterization in a GCM

The research performed under this award was conducted along 3 related fronts: (1) Refinement and assessment of parameterizations of sub-grid scale radiative transport in GCMs. (2) Diagnostic studies that use ARM observations of clouds and convection in an effort to understand the effects of moist convection on its environment, including how convection influences clouds and radiation. This aspect focuses on developing and testing methodologies designed to use ARM data more effectively for use in atmospheric models, both at the cloud resolving model scale and the global climate model scale. (3) Use (1) and (2) in combination with both models and observations of varying complexity to study key radiation feedback Our work toward these objectives thus involved three corresponding efforts. First, novel diagnostic techniques were developed and applied to ARM observations to understand and characterize the effects of moist convection on the dynamical and thermodynamical environment in which it occurs. Second, an in house GCM radiative transfer algorithm (BUGSrad) was employed along with an optimal estimation cloud retrieval algorithm to evaluate the ability to reproduce cloudy-sky radiative flux observations. Assessments using a range of GCMs with various moist convective parameterizations to evaluate the fidelity with which the parameterizations reproduce key observable features of the environment were also started in the final year of this award. The third study area involved the study of cloud radiation feedbacks and we examined these in both cloud resolving and global climate models.

54 ENVIRONMENTAL SCIENCES↗

New, low-energy excitations in 107 Mo and 109 Mo

New ground-state level with spin-parity 1/2 + is established in 109 Mo, 69.8 keV below the previously reported 5/2(+) ground state in this nucleus, based on precise spectroscopy measurements of gamma radiation following spontaneous fission of 248 Cm performed using the Eurogam2 array of anti-Compton spectrometers. Analogous measurement of gamma radiation following spontaneous fission of 252 Cf, performed using the Gammasphere array, confirms the new 1/2 + ground state of 107 Mo, proposed recently and establishes the isomeric character of the 5/2 + first excited state in 107 Mo. Two beta-decaying isomers are suggested in 111 Mo nucleus based on regular energy systematics, supporting previous predictions. Low-energy excitations in Mo isotopes are interpreted and compared to calculations reported in the literature. The results suggest shape transition from prolate to oblate deformation at N >= 67.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Modelica-based Model Library for Building Energy and Control Systems

This paper describes an open-source library with component models for building energy and control systems that is based on Modelica, an equation-based objectoriented language that is well positioned to become the standard for modeling of dynamic systems in various industrial sectors. The library is currently developed to support computational science and engineering for innovative building energy and control systems. Early applications will include controls design and analysis, rapid prototyping to support innovation of new building systems and the use of models during operation for controls, fault detection and diagnostics. This paper discusses the motivation for selecting an equation-based object-oriented language. It presents the architecture of the library and explains how base models can be used to rapidly implement new models. To demonstrate the capability of analyzing novel energy and control systems, the paper closes with an example where we compare the dynamic performance of a conventional hydronic heating system with thermostatic radiator valves to an innovative heating system. In the new system, instead of a centralized circulation pump, each of the 18 radiators has a pump whose speed is controlled using a room temperature feedback loop, and the temperature of the boiler is controlled based on the speed of the radiator pump. All flows are computed by solving for the pressure distribution in the piping network, and the controls include continuous and discrete time controls.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SU-E-T-481: In Vivo and Post Mortem Animal Irradiation: Measured Vs. Calculated Doses

Purpose: Computerized radiation therapy treatment planning is performed on almost all patients today. However it is seldom used for laboratory irradiations. The first objective is to assess whether modern radiation therapy treatment planning (RTP) systems accurately predict the subject dose by comparing in vivo and decedent dose measurements to calculated doses. The other objective is determine the importance of using a RTP system for laboratory irradiations. Methods: 5 MOSFET radiation dosimeters were placed enterically in each subject (2 sedated Rhesus Macaques) to measure the absorbed dose at 5 levels (carina, lung, heart, liver and rectum) during whole body irradiation. The subjects were treated with large opposed lateral fields and extended distances to cover the entire subject using a Varian 600C linac. CT simulation was performed ante-mortem (AM) and post-mortem (PM). To compare AM and PM doses, calculation points were placed at the location of each dosimeter in the treatment plan. The measured results were compared to the results using Varian Eclipse and Prowess Panther RTP systems. Results: The Varian and Prowess treatment planning system agreed to within in +1.5% for both subjects. However there were significant differences between the measured and calculated doses. For both animals the calculated central axis dose was higher than prescribed by 3–5%. This was caused in part by inaccurate measurement of animal thickness at the time of irradiation. For one subject the doses ranged from 4% to 7% high and the other subject the doses ranged 7% to 14% high when compared to the RTP doses. Conclusions: Our results suggest that using proper CT RTP system can more accurately deliver the prescribed dose to laboratory subjects. It also shows that there is significant dose variation in such subjects when inhomogeneities are not considered in the planning process.

60 APPLIED LIFE SCIENCES↗

On protection of Freedom's solar dynamic radiator from the orbital debris environment. Part 1: Preliminary analyses and testing

A great deal of experimentation and analysis was performed to quantify penetration thresholds of components which will experience orbital debris impacts. Penetration was found to depend upon mission specific parameters such as orbital altitude, inclination, and orientation of the component; and upon component specific parameters such as material, density and the geometry particular to its shielding. Experimental results are highly dependent upon shield configuration and cannot be extrapolated with confidence to alternate shield configurations. Also, current experimental capabilities are limited to velocities which only approach the lower limit of predicted orbital debris velocities. Therefore, prediction of the penetrating particle size for a particular component having a complex geometry remains highly uncertain. An approach is described which was developed to assess on-orbit survivability of the solar dynamic radiator due to micrometeoroid and space debris impacts. Preliminary analyses are presented to quantify the solar dynamic radiator survivability, and include the type of particle and particle population expected to defeat the radiator bumpering (i.e., penetrate a fluid flow tube). Results of preliminary hypervelocity impact testing performed on radiator panel samples (in the 6 to 7 km/sec velocity range) are also presented. Plans for further analyses and testing are discussed. These efforts are expected to lead to a radiator design which will perform to requirements over the expected lifetime.

Rhatigan, Jennifer L.↗

Hybrid honeycomb panel heat rejection system

The evolution of a hybrid honeycomb panel heat rejection system concept for future high-power spacecraft is described. Performance evaluation of this heat pipe-based hybrid radiator is based on data and prediction models from a developmental component hardware testing program. The concept integrates three high-performance components into an optimized radiator system. These components are the sideflow heat pipe transport leg, honeycomb panel evaporator, and light-weight high-efficiency heat pipe fins. A 3.05 m (10 ft.) long hybrid radiator was designed considering remnant hardware available from other Hughes programs. The key performance objective for the hybrid radiator was to demonstrate high thermal transport capacity, increased radiating fin lengths, improved thermal efficiency across structural boundaries, and reduced weight. Analysis showed that 9000 W can be transported over a 3.05 m radiator and that finlengths of up to 1 m are possible.

Tanzer, H. J.↗