Search NASA⌕ Search

SEARCH · Search NASA

Results for “Reconstruction algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Data Selection Improvement For MicroBooNE

Data selection is an extremely important part of data analysis for any experiment. Finding a physics result is often the result of sifting through a massive amount of data, keeping data that we believe to be signal, and throwing out data we do not. This process is called data selection. Creating a selection algorithm is an intensive process that must balance keeping enough data to have statistics and maximizing the signal purity of that data. We also need to choose the right reconstruction method, a tool to take raw data from the detector and convert it into physics results. In this study, we used three different reconstruction tools, Pandora, WireCell, and LANTERN, for the MicroBooNE experiment in conjunction to improve the selection algorithm for analysis. For the case of this study, we look into the charged current N proton 0 pions (CCNp0$\pi$) interaction channel. This is the dominant channel for the Short Baseline Neutrino (SBN) program and is expected to be a large contributor to the Deep Underground Neutrino Experiment (DUNE). We first investigated each of the three tools to find out more about their strengths and weaknesses as reconstructions, and compared them to the truth information directly from the MicroBooNE simulation pipeline. We then put together a direct comparison of the three methods to find which method or combination of methods would return the best result for us. While the study is ongoing, we have learned a lot about data selection for the experiment and the differences between the reconstruction tools.

Dillon, Brayden [Fermilab]↗

Studies of jet mass in dijet and W/Z + jet events

Invariant mass spectra for jets reconstructed using the anti-kt and Cambridge-Aachen algorithms are studied for different jet "grooming" techniques in data corresponding to an integrated luminosity of 5 inverse femtobarns, recorded with the CMS detector in proton-proton collisions at the LHC at a center-of-mass energy of 7 TeV. Leading-order QCD predictions for inclusive dijet and W/Z+jet production combined with parton-shower Monte Carlo models are found to agree overall with the data, and the agreement improves with the implementation of jet grooming methods used to distinguish merged jets of large transverse momentum from softer QCD gluon radiation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Jet fragmentation transverse momentum distributions in pp and p-Pb collisions at $ \sqrt{s}$, $\sqrt{s_{\mathrm{NN}}}$ = 5.02 TeV

Jet fragmentation transverse momentum ( j T ) distributions are measured in proton-proton (pp) and proton-lead (p-Pb) collisions at s NN = 5 . 02 TeV with the ALICE experiment at the LHC. Jets are reconstructed with the ALICE tracking detectors and electromagnetic calorimeter using the anti- k T algorithm with resolution parameter R = 0 . 4 in the pseudorapidity range |η| < 0 . 25. The j T values are calculated for charged particles inside a fixed cone with a radius R = 0 . 4 around the reconstructed jet axis. The measured j T distributions are compared with a variety of parton-shower models. Herwig and P ythia 8 based models describe the data well for the higher j T region, while they underestimate the lower j T region. The j T distributions are further characterised by fitting them with a function composed of an inverse gamma function for higher j T values (called the “wide component”), related to the perturbative component of the fragmentation process, and with a Gaussian for lower j T values (called the “narrow component”), predominantly connected to the hadronisation process. The width of the Gaussian has only a weak dependence on jet transverse momentum, while that of the inverse gamma function increases with increasing jet transverse momentum. For the narrow component, the measured trends are successfully described by all models except for Herwig. For the wide component, Herwig and PYTHIA 8 based models slightly underestimate the data for the higher jet transverse momentum region. These measurements set constraints on models of jet fragmentation and hadronisation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Application of morphological synthesis for understanding electrode microstructure evolution as a function of applied charge/discharge cycles

Morphological analysis and synthesis operations were employed for analysis of electrode microstructure transformations and evolution accompanying the application of charge/discharge cycles to electrochemical storage systems (batteries). Using state-of-the-art morphological algorithms, it was possible to predict microstructure evolution in porous Si electrodes for Li-ion batteries with sufficient accuracy. Algorithms for image analyses (segmentation, feature extraction, and 3D-reconstructions using 2D-images) were also developed. Altogether, these techniques could be considered supplementary to phase-field mesoscopic approach to microstructure evolution that is based upon clear and definitive changes in the appearance of microstructure. However, unlike in phase-field, the governing equations for morphological approach are geometry-, not physics-based. Similar non-physics based approach to understanding different phenomena was attempted with the introduction of cellular automata. It is anticipated that morphological synthesis and analysis will represent a useful supplementary tool to phase-field and will render assistance to unraveling the underlying microstructure-property relationships. The paper contains data on electrochemical characterization of different electrode materials that was conducted in parallel to morphological study.

25 ENERGY STORAGE↗

Stereoscopic detection of hot spots in superfluid 4 He (He II) for accelerator-cavity diagnosis

Superconducting radio-frequency (SRF) cavities cooled by superfluid 4He (He II) are building blocks of many modern particle accelerators due to their high quality factor. However, Joule heating from sub-millimeter surface defects on cavities can lead to cavity quenching, which limits the maximum acceleration gradient of the accelerators. Developing a non-contacting detection technology to accurately locate these surface hot spots is the key to improve the performance of SRF cavities and hence the accelerators. In a recent proof-of-concept experiment, we demonstrated that a molecular tagging velocimetry (MTV) technique based on the tracking of a He molecular tracer line created nearby a surface hot spot in He II can be utilized to locate the hot spot. In order to make this technique practically useful, here we describe our further development of a stereoscopic MTV setup for tracking the tracer line’s motion in three-dimensional (3D) space. We simulate a quench spot by applying a transient voltage pulse to a small heater mounted on a substrate plate. Images of the drifted tracer line, taken with two cameras from orthogonal directions, are used to reconstruct the line profile in 3D space. Here, a new algorithm for analyzing the 3D line profile is developed, which incorporates the finite size effect of the heater. We show that the center location of the heater can be reproduced on the substrate surface with an uncertainty of only a few hundred microns, thereby proving the practicability of this method.

43 PARTICLE ACCELERATORS↗

Development of thin-gap GEM- μ RWELL hybrid detectors

Micro Pattern Gaseous Detectors (MPGDs) are used for tracking in High Energy Physics and Nuclear Physics because of their large area, excellent spatial resolution capabilities and low cost. However, for high energy charged particles impacting at a large angle with respect to the axis perpendicular to detector plane, the spatial resolution degrades significantly because of the long trail of ionization charges produced in clusters all along the track in the drift region of the detector. The long ionization charge trail results in registering hits from large number of strips in the readout plane which makes it challenging to precisely reconstruct the particle’s position using simple center of gravity algorithm. As a result, the larger the drift gap, the more severe the deterioration of spatial resolution for inclined tracks. For the same reason, the position resolution is also severely degraded in a large magnetic field, where the Lorentz E x B effect causes the ionization charges to follow a curved and longer path in the detector gas volume. In this paper, we report on the development of thin-gap MPGDs as a way to maintain excellent spatial resolution capabilities of MPGD detectors over a wide angular range of incoming particles. In a thin-gap MPGD, the thickness of the gas volume in the drift region is reduced from typically 3 mm to 1 mm or less. We present preliminary test beam results demonstrating the improvement in spatial resolution from 400 m with a standard 3 mm gap μ RWELL prototype to ~140 μ m with a double amplification GEM- μ RWELL thin-gap hybrid detector. Here, we also discuss the impact of a thin-gap drift volume on other aspects of the performance of MPGD technologies such as the efficiency and detector stability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional neutron far-field tomography of a bulk skyrmion lattice

Abstract Magnetic skyrmions are localized non-collinear spin textures, characterized by an integer topological charge. Commonly observed in thin systems as two-dimensional sheets, in three dimensions skyrmions form tubes that are thought to nucleate and annihilate along their depth on points of vanishing magnetization. However, a lack of techniques that can probe the bulk of the material has made it difficult to perform experimental visualizations of skyrmion lattices and their stabilization through defects. Here we present three-dimensional visualizations of a bulk Co 8 Zn 8 Mn 4 skyrmion lattice through a tomographic algorithm applied to multiprojection small-angle neutron scattering measurements. Reconstructions of the sample show a disordered skyrmion lattice exhibiting three-dimensional topological transitions through emergent (anti)monopole branching and segmentation defect pathways. Our technique provides insights into skyrmion stabilization and topological transition pathways in a bulk skyrmion lattice, guiding the future development and manipulation of skyrmion materials for spintronic applications.

Physics↗

Mid- to long-wave infrared computational spectroscopy with a graphene metasurface modulator

In recent years there has been much interest concerning the development of modulators in the mid- to long-wave infrared, based on emerging materials such as graphene. These have been frequently pursued for optical communications, though also for other specialized applications such as infrared scene projectors. Here we investigate a new application for graphene modulators in the mid- to long-wave infrared. We demonstrate, for the first time, computational spectroscopy in the mid- to long-wave infrared using a graphene-based metasurface modulator. Furthermore, our metasurface device operates at low gate voltage. To demonstrate computational spectroscopy, we provide our algorithm with the measured reflection spectra of the modulator at different gate voltages. We also provide it with the measured reflected light power as a function of the gate voltage. The algorithm then estimates the input spectrum. We show that the reconstructed spectrum is in good agreement with that measured directly by a Fourier transform infrared spectrometer, with a normalized mean-absolute-error (NMAE) of 0.021.

36 MATERIALS SCIENCE↗

SU-D-9A-03: STAMP: Simulator for Texture Analysis in MRI/PET

Purpose: To develop a convenient simulation platform to facilitate PET/MR image analysis with the prospect of gaining a better understanding of the influence of acquisition parameters on PET/MRI textural features. The simulation platform is demonstrated by showing textural variations of a representative case study using different image acquisition parameters. Methods: The simulation platform is composed of MRI simulators JEMRIS and SIMRI to achieve simulations of customized MRI sequences on sample tumor models. The PET simulator GATE is used to get 2D and 3D Monte Carlo acquisitions of voxelized PET sources using a phantom geometry and a customized scanner architecture. The platform incorporates a series of graphical user interfaces written in Matlab. Two GUIs are used to facilitate communication with the simulation executables installed on a computer cluster. A third GUI is used to collect and display the clinical and simulated images, as well as fused PET/MRI images, and perform computation of textural features.To illustrate the capabilities of this platform, one FDG-PET and T1-weighted (T1w) digitized tumor models were generated from clinical images of a soft-tissue sarcoma patient. Numerically simulated MR images were produced using 3 different echo times (TE) and 5 different repetition times (TR). PET 2D images were simulated using an OSEM algorithm with 1 to 32 iterations and a post-reconstruction Gaussian filter of 0, 2, 4 or 6 mm width. Results: STAMP was successfully used to produce numerically simulated FDG-PET and MRI images, and to calculate their corresponding textures. Three typical textures (GLCM-Contrast, GLSZM-ZSV and NGTDM-Coarseness) were found to vary by a range of 45% on average compared to reference scanning conditions in the case of FDG-PET, and by a range of 40% in the case of T1w MRI. Conclusion: We have successfully developed a Matlab-based simulation platform to facilitate PET/MRI texture image analysis for outcome prediction.

60 APPLIED LIFE SCIENCES↗

SU-F-J-41: Experimental Validation of a Cascaded Linear System Model for MVCBCT with a Multi-Layer EPID

Purpose: The purpose of this study was to validate the use of a cascaded linear system model for MV cone-beam CT (CBCT) using a multi-layer (MLI) electronic portal imaging device (EPID) and provide experimental insight into image formation. A validated 3D model provides insight into salient factors affecting reconstructed image quality, allowing potential for optimizing detector design for CBCT applications. Methods: A cascaded linear system model was developed to investigate the potential improvement in reconstructed image quality for MV CBCT using an MLI EPID. Inputs to the three-dimensional (3D) model include projection space MTF and NPS. Experimental validation was performed on a prototype MLI detector installed on the portal imaging arm of a Varian TrueBeam radiotherapy system. CBCT scans of up to 898 projections over 360 degrees were acquired at exposures of 16 and 64 MU. Image volumes were reconstructed using a Feldkamp-type (FDK) filtered backprojection (FBP) algorithm. Flat field images and scans of a Catphan model 604 phantom were acquired. The effect of 2×2 and 4×4 detector binning was also examined. Results: Using projection flat fields as an input, examination of the modeled and measured NPS in the axial plane exhibits good agreement. Binning projection images was shown to improve axial slice SDNR by a factor of approximately 1.4. This improvement is largely driven by a decrease in image noise of roughly 20%. However, this effect is accompanied by a subsequent loss in image resolution. Conclusion: The measured axial NPS shows good agreement with the theoretical calculation using a linear system model. Binning of projection images improves SNR of large objects on the Catphan phantom by decreasing noise. Specific imaging tasks will dictate the implementation image binning to two-dimensional projection images. The project was partially supported by a grant from Varian Medical Systems, Inc. and grant No. R01CA188446-01 from the National Cancer Institute.

60 APPLIED LIFE SCIENCES↗

SU-F-J-161: Prostate Contouring in Patients with Bilateral Hip Prostheses: Impact of Using Artifact-Reduced CT Images and MRI

Purpose: To investigate the usefulness of metal artifact reduction in CT images of patients with bilateral hip prostheses (BHP) for contouring the prostate and determine if the inclusion of MR images provides additional benefits. Methods: Five patients with BHP were CT scanned using our clinical protocol (140kV, 300mAs, 3mm slices, 1.5mm increment, Philips Medical Systems, OH). Images were reconstructed with the orthopaedic metal artifact reduction (O-MAR) algorithm. MRI scanning was then performed (1.5T, GE Healthcare, WI) with a flat table-top (T{sub 2}-weighted, inherent body coil, FRFSE, 3mm slices with 0mm gap). All images were transferred to Pinnacle (Version 9.2, Philips Medical Systems). For each patient, two data sets were produced: one containing the O-MAR-corrected CT images and another containing fused MRI and O-MAR-corrected CT images. Four genito-urinary radiation oncologists contoured the prostate of each patient on the O-MAR-corrected CT data. Two weeks later, they contoured the prostate on the fused data set, blinded to all other contours. During each contouring session, the oncologists reported their confidence in the contours (1=very confident, 3=not confident) and the contouring difficulty that they experienced (1=really easy, 4=very challenging). Prostate volumes were computed from the contours and the conformity index was used to evaluate inter-observer variability. Results: Larger prostate volumes were found on the O-MAR-corrected CT set than on the fused set (p< 0.05, median=36.9cm{sup 3} vs. 26.63 cm{sup 3}). No significant differences were noted in the inter-observer variability between the two data sets (p=0.3). Contouring difficulty decreased with the addition of MRI (p<0.05) while the radiation oncologists reported more confidence in their contours when MRI was fused with the O-MAR-corrected CT data (p<0.05). Conclusion: This preliminary work demonstrated that, while O-MAR correction to CT images improves visualization of anatomy, the addition of MRI enhanced the oncologists’ confidence in contouring the prostate in patients with BHP.

60 APPLIED LIFE SCIENCES↗

Electron and photon energy calibration with the ATLAS detector using LHC Run 1 data

This paper presents the electron and photon energy calibration achieved with the ATLAS detector using about 25 fb -1 of LHC proton–proton collision data taken at centre-of-mass energies of √s=7 and 8 TeV. The reconstruction of electron and photon energies is optimised using multivariate algorithms. The response of the calorimeter layers is equalised in data and simulation, and the longitudinal profile of the electromagnetic showers is exploited to estimate the passive material in front of the calorimeter and reoptimise the detector simulation. After all corrections, the Z resonance is used to set the absolute energy scale. For electrons from Z decays, the achieved calibration is typically accurate to 0.05 % in most of the detector acceptance, rising to 0.2 % in regions with large amounts of passive material. The remaining inaccuracy is less than 0.2–1 % for electrons with a transverse energy of 10 GeV, and is on average 0.3 % for photons. The detector resolution is determined with a relative inaccuracy of less than 10 % for electrons and photons up to 60 GeV transverse energy, rising to 40 % for transverse energies above 500 GeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

model-of-perception

Algorithms for perceptually grounded evaluation of scientific visualizations, using neural reconstruction and embedding models to quantify clarity and interpretability.

Bujack, Roxana↗

Generalized spatial filtering velocimetry and accelerometry for uniform and nonuniform objects

We present a technique to measure velocity, acceleration, and higher order derivatives of motion using periodic and nonperiodic spatial filters. The technique can be applied using a single detector or an array of detectors. In one configuration, the velocity distribution of an object such as a fluid can be measured by imaging the object onto an array of detectors. In another configuration, multiple projections of an object are used to reconstruct a cross-sectional velocity distribution using a tomography algorithm. The advantages and disadvantages of our technique applied to uniform and spatially varying motions are described.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Search for New Physics in a Final State with Same-Sign Dileptons, Jets, and Missing Transverse Energy at 7 TeV Center of Mass Energy

We report on a search for new physics in a final state with two same sign leptons, missing transverse energy, and significant hadronic activity at a center of mass energy $\sqrt{s}$ = 7 TeV. The data were collected with the CMS detector at the CERN LHC and correspond to an integrated luminosity of 0.98 $\mathrm{fb}^{-1}$. Data--driven methods are developed to estimate the dominant Standard Model backgrounds. No evidence for new physics is observed. The dominant background to the analysis comes from failures of lepton identification in Standard Model $t\bar{t}$ events. The $t\bar{t}$ production cross section in the dilepton final state is measured using 3.1 $\mathrm{fb}^{-1}$ of data. The cross section is measured to be 194 $\pm$ 72 (stat) $\pm$ 24 (syst) $\pm$ 21 (lumi) pb. An algorithm is developed that uses tracking information to improve the reconstruction of missing transverse energy. The reconstruction of missing transverse energy is commissioned using the first collisio ns recorded at 0.9, 2.36 and 7 TeV data. Events with abnormally large values of missing transverse energy are identified as arising from anomalous signals in the calorimeters. Tools are developed to identify and remove these anomalous signals.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of jet yield and acoplanarity using semi-inclusive $\gamma_{\text{dir}}$+jet and $\pi^{0}$+jet distributions in $p$+$p$ and central Au+Au collisions at $\sqrt{s_{NN}} = 200$ GeV by STAR

The STAR collaboration presents measurements of semi-inclusive distributions of charged jets recoiling from high transverse energy (E T ) direct photon and π 0 triggers in p+p and central Au+Au collisions at $\sqrt{s_{NN}} = 200$ GeV. Jets are reconstructed from charged particles using the anti-k T algorithm with jet resolution parameters R = 0.2 and 0.5. The large uncorrelated background in central Au+Au collisions is corrected using a mixed-event technique. This enables a jet measurement extending to low transverse momentum and large R with well-controlled systematic uncertainties. We present measurements of the jet R dependence of suppression, intra-jet broadening, and acoplanarity of π 0 +jet and γ dir +jet for trigger E T between 9–20 GeV.

Anderson, Derek↗

An optimized buffer controlled data compression system

The digital data compression system considered uses a buffer controlled aperture algorithm which minimizes the mean-squared error between the reconstructed receiver output and transmitter input. The data compression technique selected is based on the zero-order floating aperture prediction rule. It is assumed that the statistics of the input data are initially uniformly distributed, stationary, and first-order Markov. The problem is solved for stationary data. An approach is presented for extending the results to slowly varying uniformly distributed nonstationary Markov data.

Dosik, P. H.↗

Use of maximum entropy method with parallel processing machine

The maximum entropy method (MEM) and balanced correlation method were used to reconstruct the images of low-intensity X-ray objects obtained experimentally by means of a uniformly redundant array coded aperture system. The reconstructed images from MEM are clearly superior. However, the MEM algorithm is computationally more time-consuming because of its iterative nature. On the other hand, both the inherently two-dimensional character of images and the iterative computations of MEM suggest the use of parallel processing machines. Accordingly, computations were carried out on the massively parallel processor at Goddard Space Flight Center as well as on the serial processing machine VAX 8600, and the results are compared.

Yin, Lo I.↗