Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample Calculations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Classical magnetoresistance of a two-component system induced by thermoelectric effects

Magnetotransport in a two-dimensional two-component system consisting of electrons and holes with the same concentrations is studied. Balance equations to describe charge carrier and heat transfer are derived from the classical kinetic equation. The charge-carrier density and temperature distributions and electric-current densities are calculated by solving the balance equations for a long strip sample. In a sufficiently high magnetic field, regions of increased and decreased charge-carrier density, temperature, and fluxes are formed near the sample edges. This leads to nontrivial positive magnetoresistance.

36 MATERIALS SCIENCE↗

Multicanonical sampling of rare events in random matrices

A method based on multicanonical Monte Carlo is applied to the calculation of large deviations in the largest eigenvalue of random matrices. The method is successfully tested with the Gaussian orthogonal ensemble, sparse random matrices, and matrices whose components are subject to uniform density. Specifically, the probability that all eigenvalues of a matrix are negative is estimated in these cases down to the values of {approx}10{sup -200}, a region where simple random sampling is ineffective. The method can be applied to any ensemble of matrices and used for sampling rare events characterized by any statistics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Systems and methods for fast detection of elephant flows in network traffic

In a system for efficiently detecting large/elephant flows in a network, the rate at which the received packets are sampled is adjusted according to a top flow detection likelihood computed for a cache of flows identified in the arriving network traffic. After observing packets sampled from the network, Dirichlet-Categorical inference is employed to calculate a posterior distribution that captures uncertainty about the sizes of each flow, yielding a top flow detection likelihood. The posterior distribution is used to find the most likely subset of elephant flows. The technique rapidly converges to the optimal sampling rate at a speed O(1/n), where n is the number of packet samples received, and the only hyperparameter required is the targeted detection likelihood.

Gudibanda, Aditya↗

Pt, Au, Pd and Ru Partitioning Between Mineral and Silicate Melts: The Role of Metal Nanonuggets

The partition coefficients of Pt and other Pt Group Elements (PGE) between metal and silicate D(sub Metal-Silicate) and also between silicate minerals and silicate melts D(sub Metal-Silicate) are among the most challenging coefficients to obtain precisely. The PGE are highly siderophile elements (HSE) with D(sub Metal-Silicate) >10(exp 3) due to the fact that their concentrations in silicates are very low (ppb to ppt range). Therefore, the analytical difficulty is increased by the possible presence of HSE-rich-nuggets in reduced silicate melts during experiments). These tiny HSE nuggets complicate the interpretation of measured HSE concentrations. If the HSE micro-nuggets are just sample artifacts, then their contributions should be removed before calculations of the final concentration. On the other hand, if they are produced during the quench, then they should be included in the analysis. We still don't understand the mechanism of nugget formation well. Are they formed during the quench by precipitation from precursor species dissolved homogeneously in the melts, or are they precipitated in situ at high temperature due to oversaturation? As these elements are important tracers of early planetary processes such as core formation, it is important to take up this analytical and experimental challenge. In the case of the Earth for example, chondritic relative abundances of the HSE in some mantle xenoliths have led to the concept of the "late veneer" as a source of volatiles (such as water) and siderophiles in the silicate Earth. Silicate crystal/liquid fractionation is responsible for most, if not all, the HSE variation in the martian meteorite suites (SNC) and Pt is the element least affected by these fractionations. Therefore, in terms of reconstructing mantle HSE abundances for Mars, Pt becomes a very important player. In the present study, we have performed high temperature experiments under various redox conditions in order to determine the abundances of Pt, Au, Ru and Pd in minerals (olivine and diopside) and in silicate melts, but also to characterize the sizes, density and chemistry of HSE nuggets when present in the samples.

Malavergne, V.↗

Mn doping effect on optical and ESR studies of Zn{sub 1-x}Mn{sub x}O compound sintered at different temperatures

Polycrystalline bulk samples of Zn{sub 1-x}Mn{sub x}O with x=0.02, 0.04, 0.05 and sintered at different temperatures (500 °C & 800 °C) were studied to investigate the doping effect on the structural, optical properties and spin dynamics in ZnO system. The crystallite size was seen to decrease with no significant change in other structural parameters. FTIR study showed a small effect on the Zn-O stretching bond and other bonds due to presence of Mn. Calculation from UV-Vis spectra showed increase in the optical band gap in the low temperature sintered samples due to Mn doping. In the PL spectra, the UV emission seen to dominate for the 500 °C sintered sample, for 800 °C sample the visible emission dominate indicating increase in non-radiative emission. ESR signals obtained from the microwave absorption shows ferromagnetic signal for the low temperature sintered sample only with a g value of 2.004 for the 2% Mn doped sample. The number of spin participation for resonance is calculated from the ESR signal, which supports the magnetic behaviour of this particular sample.

36 MATERIALS SCIENCE↗

Statistical fluctuations in Monte Carlo calculations

The time counter and modified Nanbu simulation techniques are analyzed, with emphasis placed on the convergence of the calculations to a steady macroscopic state. Such variables as translational and rotational temperature, and flow velocity, sampled at several points in the flowfield, are considered. Both macroscopic averages and molecular distribution functions are analyzed. The calculation of inelastic collisions, in which transfer of energy between translational and internal energy modes is performed, is achieved through the use of the Larsen-Borgnakke phenomenological model. It is noted that, with reference to translational temperature, the time counter method shows less statistical scatter than that found with the modified Nanbu simulation technique.

Boyd, I. D.↗

Corrigendum to ‘Evidence for shock heating and constraints on Martian surface temperatures revealed by 40 Ar/ 39 Ar thermochronometry of Martian meteorites’ [Geochim. Cosmochim. Acta (2010) 6900–6920]

Here, the authors regret they have discovered errors in Eq. (3) and in a spreadsheet used to calculate cosmogenic exposure ages shown in Table 1. Eq. (3) is missing a term. The spreadsheet errors concerned an incorrect cell reference and application of Eq. (3). Correction of these errors results in ~15–20% changes to the exposure ages of all samples, minor (generally <0.2%) changes to the radioisotopic ages of some samples (those that entailed a correction for chlorine-derived 38Ar calculated based on the exposure age; see Section 3.3), and statistically insignificant changes to the inferred trapped components identified through isochron analyses. These modifications have no impact on the modeling, discussions, or conclusions in the paper, nor do the changes to radioisotopic ages exceed the 1 sigma uncertainties.

58 GEOSCIENCES↗

Comparison of Engine/Inlet Distortion Measurements with MEMS and ESP Pressure Sensors

A study of active-flow control in a small-scale boundary layer ingestion inlet was conducted at the NASA Langley Basic Aerodynamic Research Tunnel (BART). Forty MEMS pressure sensors, in a rake style configuration, were used to examine both the mean (DC) and high frequency (AC) components of the total pressure across the inlet/engine interface plane. The mean component was acquired and used to calculate pressure distortion. The AC component was acquired separately, at a high sampling rate, and is used to study the unsteady effects of the active-flow control. An identical total pressure rake, utilizing an Electronically Scanned Pressure (ESP) system, was also used to calculate distortion; a comparison of the results obtained using the two rakes is presented.

Soto, Hector L.↗

Structural changes and self-activated photoluminescence in reductively annealed Sr{sub 3}AlO{sub 4}F

White light emission of self-activated photoluminescence (PL) in Sr{sub 3}AlO{sub 4}F under 254 nm light is only observed after annealing in a reducing atmosphere of 5%H{sub 2}/95%Ar. High-resolution neutron powder diffraction reveals that the FSr{sub 6} octahedrons and AlO{sub 4} tetrahedrons in this anti-perovskite structure are closer packed in reduced than in air-annealed samples which show no PL. Careful analysis of temperature-dependent neutron powder diffraction data establishes smaller isotropic displacement parameters for Sr(1) and O in Sr{sub 3}AlO{sub 4}F annealed in a reducing atmosphere indicating that the denser packing of the polyhedral sub-units leads to a slightly deeper potential for the Sr(1) and O atoms. Both the air- and reductively-annealed samples have identical thermal expansion within the temperature range between 3 and 350 K. The Debye temperatures were calculated using the atomic displacement parameters and show no significant differences between the air and reductively annealed samples making the Debye temperature a bad proxy for self-activated PL. - Graphical abstract: Annealing Sr{sub 3}AlO{sub 4}F under reducing conditions results in an intense self-activated photoluminescence which is correlated with a denser packing of FSr{sub 6} and AlO{sub 4} polyhedra. - Highlights: • Sr{sub 3}AlO{sub 4}F made in air does not show self-activated photoluminescence. • Only when annealing Sr{sub 3}AlO{sub 4}F in a reducing gas is photoluminescence observed. • FSr{sub 6} and AlO{sub 4} polyhedra in reduced Sr{sub 3}AlO{sub 4}F structure are packed more efficient. • Smaller displacement parameters are found for under-bonded Sr(1) and O sites.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measured acoustic properties of variable and low density bulk absorbers

Experimental data were taken to determine the acoustic absorbing properties of uniform low density and layered variable density samples using a bulk absober with a perforated plate facing to hold the material in place. In the layered variable density case, the bulk absorber was packed such that the lowest density layer began at the surface of the sample and progressed to higher density layers deeper inside. The samples were placed in a rectangular duct and measurements were taken using the two microphone method. The data were used to calculate specific acoustic impedances and normal incidence absorption coefficients. Results showed that for uniform density samples the absorption coefficient at low frequencies decreased with increasing density and resonances occurred in the absorption coefficient curve at lower densities. These results were confirmed by a model for uniform density bulk absorbers. Results from layered variable density samples showed that low frequency absorption was the highest when the lowest density possible was packed in the first layer near the exposed surface. The layers of increasing density within the sample had the effect of damping the resonances.

Dahl, M. D.↗

Adaptive Conformer Sampling for Property Prediction Using the Conductor-like Screening Model for Real Solvents

The valorization of lignocellulose-derived bioproducts requires effective separation from excessive water. Liquid–liquid extraction is a promising low-energy separation technology, but effective extraction requires solvent selection based on the thermodynamic properties of the bioproduct and solvent components. We propose a computational framework for predicting such properties by developing an adaptive conformer selection approach for use with COSMO-RS (conductor-like screening model for real solvents) calculations. In this framework, molecular dynamics simulations are used to generate many molecular structures (conformers) at representative temperatures in varying solvent environments. Conformers are then clustered based on structural metrics in a low-dimensional space and selected using a mixed-integer quadratic programming problem to iteratively insert a sampled conformer. At each iteration, we determine bioproduct properties using COSMO-RS. Here, we demonstrate the capability of the proposed framework on representative bioproducts to show convergence of the adaptive sampling toward experimentally measured properties with fewer calculations than required by random conformer sampling, enabling the improved screening of solvent systems for liquid-phase separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Efficient Monte Carlo Method for Modeling Radiative Transfer in Protoplanetary Disks

Monte Carlo methods have been shown to be effective and versatile in modeling radiative transfer processes to calculate model temperature profiles for protoplanetary disks. Temperatures profiles are important for connecting physical structure to observation and for understanding the conditions for planet formation and migration. However, certain areas of the disk such as the optically thick disk interior are under-sampled, or are of particular interest such as the snow line (where water vapor condenses into ice) and the area surrounding a protoplanet. To improve the sampling, photon packets can be preferentially scattered and reemitted toward the preferred locations at the cost of weighting packet energies to conserve the average energy flux. Here I report on the weighting schemes developed, how they can be applied to various models, and how they affect simulation mechanics and results. We find that improvements in sampling do not always imply similar improvements in temperature accuracies and calculation speeds.

radiative transfer↗

Statistical variability and confidence intervals for planar dose QA pass rates

Purpose: The most common metric for comparing measured to calculated dose, such as for pretreatment quality assurance of intensity-modulated photon fields, is a pass rate (%) generated using percent difference (%Diff), distance-to-agreement (DTA), or some combination of the two (e.g., gamma evaluation). For many dosimeters, the grid of analyzed points corresponds to an array with a low areal density of point detectors. In these cases, the pass rates for any given comparison criteria are not absolute but exhibit statistical variability that is a function, in part, on the detector sampling geometry. In this work, the authors analyze the statistics of various methods commonly used to calculate pass rates and propose methods for establishing confidence intervals for pass rates obtained with low-density arrays. Methods: Dose planes were acquired for 25 prostate and 79 head and neck intensity-modulated fields via diode array and electronic portal imaging device (EPID), and matching calculated dose planes were created via a commercial treatment planning system. Pass rates for each dose plane pair (both centered to the beam central axis) were calculated with several common comparison methods: %Diff/DTA composite analysis and gamma evaluation, using absolute dose comparison with both local and global normalization. Specialized software was designed to selectively sample the measured EPID response (very high data density) down to discrete points to simulate low-density measurements. The software was used to realign the simulated detector grid at many simulated positions with respect to the beam central axis, thereby altering the low-density sampled grid. Simulations were repeated with 100 positional iterations using a 1 detector/cm{sup 2} uniform grid, a 2 detector/cm{sup 2} uniform grid, and similar random detector grids. For each simulation, %/DTA composite pass rates were calculated with various %Diff/DTA criteria and for both local and global %Diff normalization techniques. Results: For the prostate and head/neck cases studied, the pass rates obtained with gamma analysis of high density dose planes were 2%-5% higher than respective %/DTA composite analysis on average (ranging as high as 11%), depending on tolerances and normalization. Meanwhile, the pass rates obtained via local normalization were 2%-12% lower than with global maximum normalization on average (ranging as high as 27%), depending on tolerances and calculation method. Repositioning of simulated low-density sampled grids leads to a distribution of possible pass rates for each measured/calculated dose plane pair. These distributions can be predicted using a binomial distribution in order to establish confidence intervals that depend largely on the sampling density and the observed pass rate (i.e., the degree of difference between measured and calculated dose). These results can be extended to apply to 3D arrays of detectors, as well. Conclusions: Dose plane QA analysis can be greatly affected by choice of calculation metric and user-defined parameters, and so all pass rates should be reported with a complete description of calculation method. Pass rates for low-density arrays are subject to statistical uncertainty (vs. the high-density pass rate), but these sampling errors can be modeled using statistical confidence intervals derived from the sampled pass rate and detector density. Thus, pass rates for low-density array measurements should be accompanied by a confidence interval indicating the uncertainty of each pass rate.

61 RADIATION PROTECTION AND DOSIMETRY↗

Laboratory studies on surface sampling of Bacillus anthracis contamination: summary, gaps, and recommendations

This article summarizes previous laboratory studies to characterize the performance of methods for collecting, storing/transporting, processing, and analyzing samples from surfaces contaminated by Bacillus anthracis or related surrogates. The focus is on plate culture and count estimates of surface contamination for swab, wipe, and vacuum samples of porous and nonporous surfaces. Summaries of the previous studies and their results were assessed to identify gaps in information needed as inputs to calculate key parameters critical to risk management in biothreat incidents. One key parameter is the number of samples needed to make characterization or clearance decisions with specified statistical confidence. Other key parameters include the ability to calculate, following contamination incidents, the 1) estimates of Bacillus anthracis contamination, as well as the bias and uncertainties in the estimates, and 2) confidence in characterization and clearance decisions for contaminated or decontaminated buildings. Gaps in knowledge and understanding identified during the summary of the studies are discussed. Recommendations are given for future evaluations of data from existing studies and possible new studies.

anthrax↗

Laboratory Studies on Surface Sampling of Bacillus anthracis Contamination: Summary, Gaps, and Recommendations

This report summarizes previous laboratory studies to characterize the performance of methods for collecting, storing/transporting, processing, and analyzing samples from surfaces contaminated by Bacillus anthracis or related surrogates. The focus is on plate culture and count estimates of surface contamination for swab, wipe, and vacuum samples of porous and nonporous surfaces. Summaries of the previous studies and their results were assessed to identify gaps in information needed as inputs to calculate key parameters critical to risk management in biothreat incidents. One key parameter is the number of samples needed to make characterization or clearance decisions with specified statistical confidence. Other key parameters include the ability to calculate, following contamination incidents, the (1) estimates of Bacillus anthracis contamination, as well as the bias and uncertainties in the estimates, and (2) confidence in characterization and clearance decisions for contaminated or decontaminated buildings. Gaps in knowledge and understanding identified during the summary of the studies are discussed and recommendations are given for future studies.

59 BASIC BIOLOGICAL SCIENCES↗

Magnetic and transport properties of cobalt doped La₀.₇Sr₀.₃MnO₃

The magnetic and transport properties of La₀.₇Sr₀.₃Mn{sub 1–x}CoxO₃ (0≤x≤1) samples were systematically studied. A magnetic phase diagram was constructed according to the observed results. At the two ends (x ≤ 0.3 and x>0.9), the samples exhibit the conventional ferromagnetism with the metallic conducting behavior, which can be interpreted in terms of the double exchange coupling between Mn (Co) ions. As for the intermediate Co-doping region (0.3<x≤0.9), the samples enter a mixed magnetic phase state, which displays the characteristics of the glassy states. According to the frequency-dependent results from the ac susceptibility, a representative frequency sensitivity factor K was calculated to be ~0.1 for the typical La₀.₇Sr₀.₃Mn₀.₆Co₀.₄O₃ sample, corresponding to the coexistence of superparamagnetic-like free spins and the reentrant spin glass. The results of the Curie-Weiss fitting of the dc magnetization suggest that the Co³⁺ ions are in the intermediate spin state with the increase of Co-doping level (x ≥ 0.3), while the Co⁴⁺ ions show the spin state transition from the high spin state to the intermediate spin state at x=0.6. The temperature dependence of resistivity shows a metal-insulator transition character for the intermediate Co-doping samples, which can be well fitted by the three dimensional variable-range-hopping model in the whole temperature range. These facts suggest that the double exchange interaction in the perovskite La₀.₇Sr₀.₃MnO₃ is destroyed by the B site doping, due to the strong competition between the double exchange and superexchange interactions in Co/Mn ions as well as the frustration of spins in the system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Viroid-like “obelisk” agents are widespread in the ocean and exceed the abundance of RNA viruses in the prokaryotic fraction

Abstract “Obelisks” are recently discovered ribonucleic acid (RNA) viroid-like elements present in diverse environments with no phylogenetic similarity to any known biological agent. obelisks were first identified in the human gut and in a commensal bacterium acting as a replicative host. They have a circular ∼1 kb RNA genome, rod-like secondary structures, and the encoding of a protein superfamily called “Oblins”. We performed a large-scale search of obelisks in the ocean using the Pebblescout program and the transcriptomic Sequence Archive Read databases, revealing the biogeography and abundance of these viroid-like RNA elements. We detected 55 obelisk genomes resulting in 35 marine clusters at the species level. These obelisks were detected in the prokaryotic fraction and to a lesser extent in the eukaryotic fraction, and distributed across all the oceans from surface to mesopelagic including the Arctic, and even in the coldest seawater of Earth beneath the Antarctic Ross Ice Shelf. The obelisk hallmark protein Oblin-1 confirmed by 3D models was found in various marine samples. Some of the detected marine obelisks harbor hammerhead self-cleaving ribozymes in both polarities. In the prokaryotic, but not the eukaryotic, fraction of the Tara Ocean dataset, relative abundance of obelisks calculated by transcriptomic fragment recruitment indicated that they are abundant in marine samples, reaching or even exceeding the relative abundance of the previously discovered uncultured RNA viruses. In conclusion, obelisks are abundant and widespread viroid-like elements that should be included in ocean biogeochemical models.

Environmental Sciences & Ecology↗

The Concentration–Mass relation of massive, dynamically relaxed galaxy clusters: agreement between observations and ΛCDM simulations

ABSTRACT The relationship linking a galaxy cluster’s total mass with the concentration of its mass profile and its redshift is a fundamental prediction of the Cold Dark Matter (CDM) paradigm of cosmic structure formation. However, confronting those predictions with observations is complicated by the fact that simulated clusters are not representative of observed samples where detailed mass profile constraints are possible. In this work, we calculate the symmetry-peakiness-alignment (SPA) morphology metrics for maps of X-ray emissivity from the three hundred project hydrodynamical simulations of galaxy clusters at four redshifts, and thereby select a sample of morphologically relaxed, simulated clusters, using observational criteria. These clusters have on average earlier formation times than the full sample, confirming that they are both morphologically and dynamically more relaxed than typical. We constrain the concentration–mass–redshift relation of both the relaxed and complete sample of simulated clusters, assuming power-law dependences on mass (κm) and 1 + z (κζ), finding κm = −0.12 ± 0.07 and κζ = −0.27 ± 0.19 for the relaxed subsample. From an equivalently selected sample of massive, relaxed clusters observed with Chandra, we find κm = −0.12 ± 0.08 and κζ = −0.48 ± 0.19, in good agreement with the simulation predictions. The simulated and observed samples also agree well on the average concentration at a pivot mass and redshift providing further validation of the ΛCDM paradigm in the properties of the largest gravitationally collapsed structures observed. This also represents the first clear detection of decreasing concentration with redshift, a longstanding prediction of simulations in data.

79 ASTRONOMY AND ASTROPHYSICS↗