Search NASA⌕ Search

SEARCH · Search NASA

Results for “Samples”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Requesting Antarctic Meteorite Samples for Research

The U.S. Antarctic meteorite program began in the 1970’s and has provided more than 24,000 samples. The program is based on a three agency agreement between NASA, the National Science Foundation, and the Smithsonian Institution. The collection, stored at the Johnson Space Center and the Smithsonian, is one of the largest collections of meteorites in the world and features samples from the moon, Mars, asteroids, and material from the early solar system. A brief overview of the collection shows it contains 92.2% ordinary chondrites (7205 H, 9126 L, 3890 LL, 146 enstatite, 30 R chondrites, 3.2% (973) carbonaceous chondrites, 3.7% (560) achondrites (1.7% HED), 118 irons, 27 pallasites, 41 mesosiderites, as well as many puzzling, ungrouped meteorites. JSC has sent splits of over 20,000 meteorite samples to more than 500 scientists around the world since 1977. After the meteorites are collected in Antarctica, they are shipped frozen to JSC in Houston, TX, arriving in April following the field season. The Astromaterials Curation Office at JSC is responsible for: - providing supplies and tools for the field team. - receiving the frozen meteorites. - staging: repackaging and changing the samples’ field identification numbers with official names. - submitting the names to the Nomenclature Committee of the Meteoritical Society for approval as new meteorites. - providing storage and handling of the meteorites in a class 10,000 clean room. - initial processing: weighing, measuring, describing, and photographing the sample and providing a chip for classification to the Smithsonian Institution staff. - the issuing of two newsletters per year, announcing hundreds of new meteorites. - the handling of requests from the scientific community and the allocation of those requests that are approved. - making petrographic thin and thick sections for the JSC library and scientific investigators. - maintaining the meteorite database with more than 76,000 sample splits.

C.E. Satterwhite↗

Investigating Amino Acid Heterogeneity in Milligram-Scale Samples of the Murchison CM2 Carbonaceous Chondrite

Analyses of different aliquots of the Tagish Lake meteorite have resulted in amino acid abundance variations of an order of magnitude or more, even when performed using the same techniques, by the same personnel, in the same laboratories (e.g., Simkus et al. 2019). Up to ~five-fold variations have been observed for specific amino acids in different samples of the same meteorite, such as α aminoisobutryic acid (AIB) in Murchison. These variations are often attributed differing sample composition or differing alteration history, neither of which is mutually exclusive. Distinguishing between these two explanations is challenging and time consuming, requiring detailed mineralogical analyses to be performed in conjunction with high precision organics analysis. The potential for innate sample-level heterogeneity presents a significant complication when parsing the effects of different processes or conditions during preparation of meteorite samples for analysis, as differences in organic yields or abundances could be due to differences in laboratory processing or differences among the samples themselves. In this work, we investigated the degree of innate organic heterogeneity present in a single ~250 mg chip of divided into 21 samples.

A. S. Burton↗

Improved Aerothermal Reliability Analysis Enabled by the Mars Sample Return Earth Entry System Aerothermal Database

The Mars Sample Return (MSR) campaign is a series of missions designed to retrieve Martian rock and soil samples for detailed study on Earth. The campaign is split into three primary phases: sample collection with the Mars2020 rover, retrieval with the Sample Return Lander (SRL) and Mars Ascent Vehicle (MAV), and then return to Earth with the Earth Return Orbiter (ERO) and Capture, Containment, and Return System (CCRS) [1]. The final sequence in the Earth return phase is the delivery and entry of the Earth Entry System (EES) sample return capsule. Due to unprecedented planetary protection concerns, the sample return capsule is subject to strict reliability requirements. To this end, the MSR-EES aerothermal team has implemented a flexible aerothermal database architecture capable of integration with state-of-the-art trajectory codes to provide a more rigorous aerothermal reliability analysis. The EES database enables the generation of environments at any location on the heatshield and can incorporate trajectory uncertainties to both statistically quantify aerothermal environments for arcjet testing and produce material response boundary conditions to rigorously select thermal protection system (TPS) sizing environments. This poster will not discuss the fundamental modeling assumptions included in the database, and will instead focus on the downstream reliability analyses that can be performed with a database of this architecture.

MSR-EES↗

Nanoscale Mineralogy of Bennu Samples Returned by OSIRIS-REx

The OSIRIS-REx spacecraft returned regolith samples from asteroid Bennu and an initial sample was allocated for quick-look (QL) analyses. These QL particles were recovered from the avionics deck of the sample canister and were used to test the hypothesis that this dust is broadly representative of the bulk sample. The QL sample analyses showed that the materials are dominated by hydrated silicates, sulfides, magnetite, phosphates, and abundant organic matter, in addition to other minor/trace phases. Here we report our preliminary transmission electron microscope (TEM) observations for the nanoscale mineralogy of Bennu samples.

L P Keller↗

Analyses of the MISSE 9-15 Polymers and Composites Experiment 1-4 (PCE 1-4) Contamination Samples

Spacecraft in low Earth orbit (LEO) are subjected to harsh environmental conditions, including radiation (cosmic rays, ultraviolet (UV), x-ray and charged particle radiation), micrometeoroids and orbital debris, temperature extremes, thermal cycling, and atomic oxygen (AO). These environmental exposures can result in erosion, embrittlement and optical property degradation of susceptible materials threatening spacecraft performance and durability. To increase our understanding of environmental effects such as AO erosion and radiation induced embrittlement of spacecraft materials, NASA Glenn Research Center developed a series of experiments that were flown as part of the Materials International Space Station Experiment (MISSE) missions on the exterior of the International Space Station (ISS). Recently, four Glenn experiments with 365 flight samples were flown on ISS’s MISSE-Flight Facility (MISSE-FF). These experiments are the Polymers and Composites Experiment-1 (PCE-1) flown as part of the MISSE-9 mission, the PCE-2 flown as part of the MISSE-10 mission, the PCE-3 flown as part of the MISSE-12 and MISSE-15 missions, and the PCE-4 flown as part of the MISSE-13 mission. Each of these experiments included passive contamination witness samples in each flight direction for post-flight molecular contamination analyses. A total of 13 contamination flight samples were flown. The post-flight analyses of the PCE 1-4 contamination samples include X-ray Photoelectron Spectroscopy (XPS) analyses (surface and ion sputter depth analyses) and optical properties (total reflectance, total transmittance and solar absorptance). This paper provides results of post-flight analyses of the PCE 1-4 contamination samples and their corresponding control samples. Knowledge of on-orbit contamination is important for the PCE 1-4 flight data interpretation.

Atomic Oxygen↗

Preliminary Design of Robotic Control Software for Mars Sample Return - Capture, Containment, and Return System

The Mars Sample Return (MSR) campaign aims to acquire and return to Earth a set of Mars samples for investigation in terrestrial laboratories. Mars 2020 has collected an adequate number of samples and deposited them in sealed sample tubes at a designated Martian depot. Sample tubes will be placed in cylindrical containers called Orbiting Samples (OS) by the Perseverance Rover, and later brought to Earth by the Earth Return Orbiter (ERO) and the MSR - Capture, Containment, and Return System (CCRS). Robot Software (RSW) is a set of software processes for commanding and monitoring the avionics that controls robotic mechanisms designed to sterilize and install OS into Earth Entry System (EES) for return to Earth. This paper describes a preliminary design of RSW including motion modes, architecture, and finite state machine. Additionally, software engineering procedures and testing of RSW is provided. A preliminary performance analysis is presented and the paper concludes with future work and a discussion of design decisions.

MSR↗

The Nature of Space Weathering in Samples From Asteroid (162173) Ryugu Revealed By Coordinated Analysis

Space weathering, driven primarily by micrometeorite bombardment and solar wind ion irradiation, alters the morphology, microstructure, and chemistry of the surface regolith on airless bodies. The accumulation of microstructural and chemical space weathering features, including melt deposits, amorphous rims, and nanophase iron-bearing particles (npFe), are associated with alterations of the spectral properties of the regolith. In particular, space weathering changes the spectral slope and reflectance of surface materials, and causes the attenuation of characteristic absorption bands in the visible to near-infrared wave-lengths, as well as a shift towards longer wavelengths of the Christiansen feature (CF)in thermal infrared spectra. Previous studies of space weathering characteristics have focused on siliceous bodies like the Moon and S-type asteroid Itokawa. However, observations of asteroid Ryugu by the JAXA Hayabusa2 spacecraft and subsequent analyses of returned samples revealed carbonaceous and hydrated materials. These samples provided our first opportunity to constrain the effects of space weathering processes on primitive, C-type asteroids. Analyses of returned samples to understand the space weathering of carbonaceous materials are important for accurately interpreting remote sensing observations of carbonaceous asteroids. In addition, the analysis of Hayabusa2 samples from Ryugu paved the way for the analysis of samples from the asteroid Bennu, re-turned by the NASA OSIRIS-REx mission. As space weathering impacts the microstructure, chemistry, and spectral characteristics of asteroidal surfaces, here we report the results of a coordinated analytical study of the micro-and nano-scale signatures of space weathering in samples returned from Ryugu.

L E Melendez↗

Preservation of Previously Unsampled Primordial Isotopic Components in Ryugu and Bennu Samples

Ivuna-type (CI) carbonaceous chondrites are primitive meteorites whose relative elemental abundances closely match the solar photosphere 1 , making them critical benchmarks for the bulk chemical and isotopic composition of the planet-forming disk. Recent sample-return missions to Ryugu 2 and Bennu 3 have enabled direct laboratory analysis of these rubble-pile CI-like asteroids 4 , formed from the reaccumulated fragments of once-larger parent bodies. As such, they may retain a broader spectrum of primordial nucleosynthetic components than is preserved in known meteorites. Here, we report the nucleosynthetic compositions of silicon (μ 30 Si), magnesium (μ 26 Mg*), and iron (μ 54 Fe), three of the four most abundant planet-building elements, in samples from Ryugu and Bennu, along with the newly discovered Oued Chebeika 002 CI chondrite 5 . In contrast to the isotopic homogeneity of CI chondrites, Ryugu and Bennu preserve resolvable μ 26 Mg* and μ 30 Si heterogeneity, revealing μ 26 Mg*- and μ 30 Si-rich nucleosynthetic components not sampled in meteorites. These components may reflect the preservation of previously unsampled primordial isotopic signals, prior to thermal processing 6,7 and late infall of primordial molecular cloud material to the outer disk 8,9 . Additionally, Ryugu particle C0002 exhibits a μ 26 Mg*-poor and μ 54 Cr-rich signature, consistent with incorporation of presolar material from massive supernovae 10,11 . Ryugu and Bennu samples define one end of a μ 54 Fe–μ 30 Si array among carbonaceous asteroid materials 9 , suggesting that the isotopic compositions of these asteroidal materials reflect mixing between early disk isotopic components identified in this study and material derived from the outermost disk 9 . This observation demonstrates that materials with solar chemical abundances can nonetheless exhibit markedly distinct nucleosynthetic signatures. Thus, Ryugu and Bennu samples are critical records of nucleosynthetic diversity among carbonaceous asteroids and underscore the value of sample-return missions in accessing primitive isotopic signatures absent from meteorite collections.

Martin Bizzarro↗

Optical method for the characterization of laterally-patterned samples in integrated circuits

Disclosed is a method for characterizing a sample having a structure disposed on or within the sample, comprising the steps of applying a first pulse of light to a surface of the sample for creating a propagating strain pulse in the sample, applying a second pulse of light to the surface so that the second pulse of light interacts with the propagating strain pulse in the sample, sensing from a reflection of the second pulse a change in optical response of the sample, and relating a time of occurrence of the change in optical response to at least one dimension of the structure.

Maris, Humphrey J↗

Optical method and system for the characterization of laterally-patterned samples in integrated circuits

Disclosed is a method for characterizing a sample having a structure disposed on or within the sample, comprising the steps of applying a first pulse of light to a surface of the sample for creating a propagating strain pulse in the sample, applying a second pulse of light to the surface so that the second pulse of light interacts with the propagating strain pulse in the sample, sensing from a reflection of the second pulse a change in optical response of the sample, and relating a time of occurrence of the change in optical response to at least one dimension of the structure.

36 MATERIALS SCIENCE↗

Portable sample preparation and analysis system for micron and sub-micron particle characterization using light scattering and absorption spectroscopy

There is provided a method and device for remote sampling, preparation and optical interrogation of a sample using light scattering and light absorption methods. The portable device is a filtration-based device that removes interfering background particle material from the sample matrix by segregating or filtering the chosen analyte from the sample solution or matrix while allowing the interfering background particles to be pumped out of the device. The segregated analyte is then suspended in a diluent for analysis. The device is capable of calculating an initial concentration of the analyte, as well as diluting the analyte such that reliable optical measurements can be made. Suitable analytes include cells, microorganisms, bioparticles, pathogens and diseases. Sample matrixes include biological fluids such as blood and urine, as well as environmental samples including waste water.

47 OTHER INSTRUMENTATION↗

Application of laser induced breakdown spectroscopy for total carbon quantification in soil samples

The increase of greenhouse gas (i.e., CO{sub 2}) levels in the atmosphere has caused noticeable climate change. Many nations are currently looking into methods of permanent underground storage for CO{sub 2} in an attempt to mitigate this problem. The goal of this work is to develop a process for studying the total carbon content in soils before, during, and after CO{sub 2} injection to ensure that no leakage is occurring or to determine how much is leaking if it is occurring and what effect it will have on the ecosystem between the injection formation and the atmosphere. In this study, we quantitatively determine the total carbon concentration in soil using laser-induced breakdown spectroscopy (LIBS). A soil sample from Starkville, Mississippi, USA was mixed with different amounts of carbon powder, which was used as a calibration for additional carbon in soil. Test samples were prepared by adding different but known amounts of carbon powder to a soil sample and then mixing with polyvinyl alcohol binder before being pressed into pellets. LIBS spectra of the test samples were collected and analyzed to obtain optimized conditions for the measurement of total carbon in soil with LIBS. The total carbon content in the samples was also measured by a carbon analyzer, and the data (average of triplicates) were used as a reference in developing calibration curves for a modified version of the single linear regression model and the multiple linear regression model. The calibration data were then used to determine the total carbon concentration of an unknown sample. This work is intended to be used in the initial development of a miniaturized, field-portable LIBS analyzer for CO{sub 2} leak detection.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Analysis of Bulk and Thin Film Model Samples Intended for Investigating the Strain Sensitivity of Niobium-Tin

Bulk samples and thin films were fabricated and characterized to determine their suitability for studying the effect of composition and morphology on strain sensitivity. Heat capacity and resistivity data are used to determine the critical temperature distribution. It is found that all bulk samples contain stoichiometric Nb{sub 3}Sn regardless of their nominal Nb to Sn ratio. Furthermore, in bulk samples with Cu additions, a bi-modal distribution of stoichiometric and off-stoichiometric Nb-Sn is found. Thus the nominally off-stoichiometric bulk samples require additional homogenization steps to yield homogeneous off-stoichiometric samples. A binary magnetron-sputtered thin film has the intended off-stoichiometric Nb-Sn phase with a mid-point critical temperature of 16.3 K. This type of sample is a suitable candidate for investigating the strain sensitivity of A15 Nb{sub 1-{beta}}Sn{sub {beta}}, with 0.18 < {beta} < 0.25. The strain sensitivity of Nb-Sn as a function of composition and morphology is important for an in-depth understanding of the strain sensitivity of composite Nb{sub 3}Sn wires.

43 PARTICLE ACCELERATORS↗

Interface for the rapid analysis of liquid samples by accelerator mass spectrometry

An interface for the analysis of liquid sample having carbon content by an accelerator mass spectrometer including a wire, defects on the wire, a system for moving the wire, a droplet maker for producing droplets of the liquid sample and placing the droplets of the liquid sample on the wire in the defects, a system that converts the carbon content of the droplets of the liquid sample to carbon dioxide gas in a helium stream, and a gas-accepting ion source connected to the accelerator mass spectrometer that receives the carbon dioxide gas of the sample in a helium stream and introduces the carbon dioxide gas of the sample into the accelerator mass spectrometer.

47 OTHER INSTRUMENTATION↗

Microwave heating of aqueous samples on a micro-optical-electro-mechanical system

Apparatus for heating a sample includes a microchip; a microchannel flow channel in the microchip, the microchannel flow channel containing the sample; a microwave source that directs microwaves onto the sample for heating the sample; a wall section of the microchannel flow channel that receives the microwaves and enables the microwaves to pass through wall section of the microchannel flow channel, the wall section the microchannel flow channel being made of a material that is not appreciably heated by the microwaves; a carrier fluid within the microchannel flow channel for moving the sample in the microchannel flow channel, the carrier fluid being made of a material that is not appreciably heated by the microwaves; wherein the microwaves pass through wall section of the microchannel flow channel and heat the sample.

42 ENGINEERING↗

Optical method and system for the characterization of laterally-patterned samples in integrated circuits

Disclosed is a method for characterizing a sample having a structure disposed on or within the sample, comprising the steps of applying a first pulse of light to a surface of the sample for creating a propagating strain pulse in the sample, applying a second pulse of light to the surface so that the second pulse of light interacts with the propagating strain pulse in the sample, sensing from a reflection of the second pulse a change in optical response of the sample, and relating a time of occurrence of the change in optical response to at least one dimension of the structure.

36 MATERIALS SCIENCE↗

Reconstruction of Intensity From Covered Samples

The safe handling of activated samples requires containment and covering the sample to eliminate any potential for contamination. Subsequent characterization of the surface with x-rays ideally necessitates a thin film. While many films appear visually transparent, they are not necessarily x-ray transparent. Each film material has a unique beam attenuation and sometimes have amorphous peaks that can superimpose with those of the sample. To reconstruct the intensity of the underlying activated sample, the x-ray attenuation and signal due to the film needs to be removed from that of the sample. This requires the calculation of unique deconvolution parameters for the film. The development of a reconstruction procedure for a contained/covered sample is described.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Direct impact aerosol sampling by electrostatic precipitation

The present disclosure provides apparatuses for collecting aerosol samples by ionizing an air sample at different degrees. An air flow is generated through a cavity in which at least one corona wire is disposed and electrically charged to form a corona therearound. At least one grounded sample collection plate is provided downstream of the at least one corona wire so that aerosol ions generated within the corona are deposited on the at least one grounded sample collection plate. A plurality of aerosol samples ionized to different degrees can be generated. The at least one corona wire may be perpendicular to the direction of the flow, or may be parallel to the direction of the flow. The apparatus can include a serial connection of a plurality of stages such that each stage is capable of generating at least one aerosol sample, and the air flow passes through the plurality of stages serially.

47 OTHER INSTRUMENTATION↗