Search NASA⌕ Search

SEARCH · Search NASA

Results for “Small”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Inclusive prompt photon production in electron-nucleus scattering at small x

Here, we compute the differential cross-section for inclusive prompt photon production in deeply inelastic scattering (DIS) of electrons on nuclei at small x in the framework of the Color Glass Condensate (CGC) effective theory. The leading order (LO) computation in this framework resums leading logarithms in x as well as power corrections to all orders in Q s,A 2 /Q 2 , where Q s,A (x) is the nuclear saturation scale. This LO result is proportional to universal dipole and quadrupole Wilson line correlators in the nucleus. In the soft photon limit, the Low-Burnett-Kroll theorem allows us to recover existing results on inclusive DIS dijet production. The k⊥ and collinearly factorized expressions for prompt photon production in DIS are also recovered in a leading twist approximation to our result. In the latter case, our result corresponds to the dominant next-to-leading order (NLO) perturbative QCD contribution at small x. We next discuss the computation of the NLO corrections to inclusive prompt photon production in the CGC framework. In particular, we emphasize the advantages for higher order computations in inclusive photon production, and for fully inclusive DIS, arising from the simple momentum space structure of the dressed quark and gluon “shock wave” propagators in the “wrong” light cone gauge A – = 0 for a nucleus moving with P N + → ∞.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Probing small-scale power spectra with pulsar timing arrays

Models of Dark Matter (DM) can leave unique imprints on the Universe’s small scale structure by boosting density perturbations on small scales. We study the capability of Pulsar Timing Arrays to search for, and constrain, subhalos from such models. The models of DM we consider are ordinary adiabatic perturbations in ΛCDM, QCD axion miniclusters, models with early matter domination, and vector DM produced during inflation. We show that ΛCDM, largely due to tidal stripping effects in the Milky Way, is out of reach for PTAs. Axion miniclusters may be within reach, although this depends crucially on whether the axion relic density is dominated by the misalignment or string contribution. Models where there is matter domination with a reheat temperature below 1 GeV may be observed with future PTAs. Lastly, vector DM produced during inflation can be detected if it is lighter than 10 16 GeV. We also make publicly available a Python Monte Carlo tool for generating the PTA time delay signal from any model of DM substructure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Small instanton-induced flavor invariants and the axion potential

Small instantons which increase the axion mass due to an appropriate modification of QCD at a UV scale ΛSI, can also enhance the effect of CP-violating operators to shift the axion potential minimum by an amount, θ ind, proportional to the flavorful couplings in the SMEFT. Since physical observables must be flavor basis independent, we construct a basis of determinant-like flavor invariants that arise from instanton calculations containing the effects of dimension-six CP-odd operators at the scale Λ CP . This new basis provides a more reliable estimate of the shift θ ind, that is severely constrained by neutron electric dipole moment experiments. In particular, for the case of four-quark, semi-leptonic and gluon dipole operators, these invariants are then used to provide improved limits on the ratio of scales Λ SI /Λ CP for different flavor scenarios. The CP-odd flavor invariants also provide a classification of the leading effects from Wilson coefficients, and as an example, we show that a semi-leptonic four-fermion operator is subdominant compared to the four-quark operators. More generally, the flavor invariants, together with an instanton NDA, can be used to more accurately estimate small instanton effects in the axion potential that arise from any SMEFT operator.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Helicity at small x: oscillations generated by bringing back the quarks

We construct a numerical solution of the recently-derived large-N c &N f small-x helicity evolution equations with the aim to establish the small-x asymptotics of the quark helicity distribution beyond the large-N c limit explored previously in the same framework. (Here N c and N f are the numbers of quark colors and flavors.) While the large-N c helicity evolution involves gluons only, the large-N c &N f evolution includes contributions from quarks as well. We find that adding quarks to the evolution makes quark helicity distribution oscillate as a function of x. Our numerical results in the large-N c &N f limit lead to the x-dependence of the flavor-singlet quark helicity distribution which is well-approximated by $$ {\left.\Delta \Sigma \left(x,{Q}^2\right)\right|}_{\mathrm{large}\hbox{-} {N}_c\&{N}_f}\sim {\left(\frac{1}{x}\right)}^{\alpha_h^q}\cos \left[{\omega}_q\ln \left(\frac{1}{x}\right)+{\varphi}_q\right]. $$. The power $α^{q}_{h}$ exhibits a weak N f -dependence, and, for all Nf values considered, remains very close to $α^{q}_{h}$(N f =0)=$\left(4/\sqrt{3}\right)\sqrt{\alpha_s{N}_c/\left(2\pi \right)}$ obtained earlier in the large-N c limit. The novel oscillation frequency ω q and phase shift φ q depend more strongly on the number of flavors N f (with ω q = 0 in the pure-glue large-N c limit). The typical period of oscillations for ΔΣ is rather long, spanning many units of rapidity. We speculate whether the oscillations we find are related to the sign variation with x seen in the strange quark helicity distribution extracted from the data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Medium modification of the shape of small-radius jets in central Pb-Pb collisions at $\sqrt{s_{\mathrm{NN}}}=2.76$ TeV

We present the measurement of a new set of jet shape observables for track-based jets in central Pb-Pb collisions at $\sqrt{s_{\mathrm{NN}}}=2.76$ TeV. The set of jet shapes includes the first radial moment or angularity, g; the momentum dispersion, pTD; and the difference between the leading and sub-leading constituent track transverse momentum, LeSub. These observables provide complementary information on the jet fragmentation and can constrain different aspects of the theoretical description of jet-medium interactions. The jet shapes were measured for a small resolution parameter R = 0.2 and were fully corrected to particle level. The observed jet shape modifications indicate that in-medium fragmentation is harder and more collimated than vacuum fragmentation as obtained by PYTHIA calculations, which were validated with the measurements of the jet shapes in proton-proton collisions at $\sqrt{s}=7$ TeV. The comparison of the measured distributions to templates for quark and gluon-initiated jets indicates that in-medium fragmentation resembles that of quark jets in vacuum. We further argue that the observed modifications are not consistent with a totally coherent energy loss picture where the jet loses energy as a single colour charge, suggesting that the medium resolves the jet structure at the angular scales probed by our measurements (R = 0.2). Furthermore, we observe that small-R jets can help to isolate purely energy loss effects from other effects that contribute to the modifications of the jet shower in medium such as the correlated background or medium response.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dynamical axion misalignment with small instantons

We present a new mechanism to relax the initial misalignment angle of the QCD axion and raise the cosmological bound on the axion decay constant. The QCD axion receives a contribution from small UV instantons during inflation, which raises its mass to the inflationary Hubble scale. This makes the axion start rolling down its potential early on. In the scenario, the standard model Yukawa couplings of quarks are dynamical, being of order one during the inflationary era and reducing to their standard model values once it ends. This means that after inflation the contribution of the small instantons is suppressed, and the axion potential reduces to the standard one from the usual IR instantons. As a result, when the axion starts to oscillate again after inflation, the initial misalignment angle is suppressed due to the dynamics during inflation. While the general idea of dynamical axion misalignment has been discussed in the literature before, we present in detail the major bottleneck on the mismatching between the minima of the axion potentials during and after inflation, and how it is circumvented in our scenario via the Froggatt-Nielsen mechanism. Taking into account of all the constraints, we find that the axion decay constant could be raised to the GUT scale, 10 15 GeV, in our scenario.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The utility of diffusion-weighted imaging in improving the sensitivity of LI-RADS classification of small hepatic observations suspected of malignancy

Purpose: We investigated the added value of diffusion-weighted imaging (DWI)/apparent diffusion coefficient (ADC) in the categorization of small hepatic observation (≤ 20 mm) detected in patients with chronic liver disease in reference to LI-RADS (liver imaging reporting and data system) classification system. Methods: We prospectively evaluated 165 patients with chronic liver disease with small hepatic observations (≤ 20 mm) which were previously categorized as LI-RADS grade 3–5 on dynamic contrast-enhanced CT (DCE-CT). All patients were submitted to a functional MRI including DCE and DWI. Using LI-RADS v2017, two radiologists independently evaluated the observations and assigned a LI-RADS category to each observation using DCE-MRI alone and combined DCE-MRI and DWI/ADC. In the combined technique, the radiologists assigned a LI-RADS category based on a modified LI-RADS criteria in which restricted diffusion on DWI was considered a major feature of HCC. We evaluated the inter-reader agreement with Kappa statistics and compared the diagnostic performance of the LI-RADS with two imaging techniques by Fisher’s exact test using histopathology as the reference standard. Results: Combined technique in LI-RADS yielded better sensitivities (reader 1, 97% [65/67]; reader 2, 95.5% [64/67]) for HCC diagnosis than DCE-MRI alone (reader 1, 80.6% [54/67], p = 0.005; reader 2, 83.6% [56/67], p = 0.04). The specificities were insignificantly lower in combined technique (reader 1, 88.4% [107/121]; reader 2, 77.7% [94/121]) than in DCE-MRI alone (reader 1, 90.9% [110/121], p = 0.67; reader 2, 79.3% [96/121], p = 0.88). The inter-reader agreement of the LI-RADS scores between combined technique and DCE-MRI was good (κ = 0.765). Conclusion: The use of DWI/ADC as an additional major criterion, improved the sensitivity of LI-RADS in the diagnosis of HCC while keeping high specificity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Outpatient Management of Postbiopsy Pneumothorax with Small-Caliber Chest Tubes: Factors Affecting the Need for Prolonged Drainage and Additional Interventions

The aim of this study was to evaluate the efficacy of outpatient management of postbiopsy pneumothoraces with small-caliber chest tubes and to assess the factors that influence the need for prolonged drainage or additional interventions.We evaluated the medical records of patients who were treated with small-caliber chest tubes attached to Heimlich valves for pneumothoraces resulting from image-guided transthoracic needle biopsy to determine the hospital admission rates, the number of days the catheters were left in place, and the need for further interventions. We also evaluated the patient, lesion, and biopsy technique characteristics to determine their influence on the need for prolonged catheter drainage or additional interventions. Of the 191 patients included in our study, 178 (93.2%) were treated as outpatients. Ten patients (5.2%) were admitted for chest tube-related problems, either for underwater suction (n = 8) or for pain control (n = 2). No further interventions were required in 146 patients (76.4%), with successful removal of the chest tubes the day after the biopsy procedure. Prolonged catheter drainage (mean, 4.3 days) was required in 44 patients (23%). Nineteen patients (9.9%) underwent additional interventions for management of pneumothorax. Presence of emphysema was noted more frequently in patients who required additional interventions or prolonged chest tube drainage than in those who did not (51.1% vs. 24.7%; p = 0.001).We conclude that use of the Heimlich valve allows safe and successful outpatient treatment of most patients requiring chest tube placement for postbiopsy pneumothorax. Additional interventions or prolonged chest tube drainage are needed more frequently in patients with emphysema in the needle path.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Treatment of an Unusual Complication of Endovenous Laser Therapy: Multiple Small Arteriovenous Fistulas Causing Complete Recanalization

A 67-year-old woman was admitted to our institution with pain, night cramping, and visible varicose veins on her left leg. Doppler ultrasonography revealed continuous reflux in the great saphenous vein when the patient did the Valsalva maneuver. Endovenous laser therapy was applied to the great saphenous vein. Doppler ultrasonography 7 days later showed recanalization of, and arterialized flow in, the great saphenous vein. There also were small arterial vessels adjunct to the recanalized side. A left femoral angiography via a right femoral approach showed multiple small arteriovenous fistulas between superficial femoral artery muscle branches and the great saphenous vein. A second endovenous laser treatment was done at 80 J/cm, but the recanalization persisted. We offered to treat this endovascularly, but the patient preferred a surgical option. To the best of our knowledge, this is the first report of the demonstration of such a complication with endovenous laser therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lung Radiofrequency Ablation for the Treatment of Unresectable Recurrent Non-Small-Cell Lung Cancer After Surgical Intervention

Purpose: A retrospective evaluation was done of clinical utility of lung radiofrequency (RF) ablation in recurrent non-small-cell lung cancer (NSCLC) after surgical intervention. Methods: During May 2003 to October 2010, 44 consecutive patients (26 male and 18 female) received curative lung RF ablation for 51 recurrent NSCLC (mean diameter 1.7 {+-} 0.9 cm, range 0.6 to 4.0) after surgical intervention. Safety, tumor progression rate, overall survival, and recurrence-free survival were evaluated. Prognostic factors were evaluated in multivariate analysis. Results: A total of 55 lung RF sessions were performed. Pneumothorax requiring pluerosclerosis (n = 2) and surgical suture (n = 1) were the only grade 3 or 4 adverse events (5.5%, 3 of 55). During mean follow-up of 28.6 {+-} 20.3 months (range 1 to 98), local tumor progression was found in 5 patients (11.4%, 5 of 44). The 1-, 3-, and 5-year overall survival rates were 97.7, 72.9, and 55.7%, respectively. The 1- and 3-year recurrence-free survival rates were 76.7 and 41.1%, respectively. Tumor size and sex were independent significant prognostic factors in multivariate analysis. The 5-year survival rates were 73.3% in 18 women and 60.5% in 38 patients who had small tumors measuring {<=}3 cm. Conclusion: Our results suggest that lung RF ablation is a safe and useful therapeutic option for obtaining long-term survival in treated patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High-Frequency Jet Ventilation During Cryoablation of Small Renal Tumours

AimTo evaluate the effect of high-frequency jet ventilation (HFJV) in place of standard intermittent positive-pressure ventilation (IPPV) on procedure duration, patient radiation dose, complication rates, and outcomes during CT-guided cryoablation of small renal tumours.Materials and MethodsOne hundred consecutive CT-guided cryoablation procedures to treat small renal tumours under general anaesthesia were evaluated—50 with standard IPPV and 50 after the introduction of HFJV as standard practice. Anaesthesia and procedural times, ionising radiation dose, complications, and 1-month post-treatment outcomes were collected.ResultsHFJV was feasible and safe in all cases. Mean procedure time and total anaesthetic time were shorter with HFJV (p = <0.0001). The number of required CT acquisitions (p = 0.0002) and total procedure patient radiation dose (p = 0.0027) were also lower in the HFJV group compared with the IPPV group. There were a total of four complications of Clavien–Dindo classification 3 or above—three in the IPPV group and one in the HFJV group. At 1-month follow-up, two cases (both in the IPPV group) demonstrated subtotal treatment. Both cases were subsequently successfully retreated with cryoablation.ConclusionBy reducing target tumour motion during CT-guided renal cryoablation, HFJV can reduce procedure times and exposure to ionising radiation. HFJV provides an important adjunct to complex image-guided interventions, with potential to improve safety and treatment outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ablation Volume Measurement After Percutaneous Cryoablation Using a Two-cryo-probe Technique for Small Hepatocellular Carcinomas

Purpose: To calculate the ablation volume of percutaneous cryoablation (PCA) with a two-cryo-probe technique for small hepatocellular carcinomas (HCCs) and to assess risk factors for local tumor recurrence (LTR). Materials and Methods: Between January 2013 and June 2017, 96 patients (mean age, 60.7 years; range, 37–83 years) with 106 small HCCs were retrospectively analyzed. The ablation volume, technical success, LTR rates, and complications were evaluated. Ablation volume was measured after the first freezing and immediately after completing PCA twice via computed tomography imaging. Prognostic factors associated with LTR were analyzed. Results: Technical success was achieved in all patients. The mean final ablation volume was 19.1 ± 4.8 cm{sup 3}, which was significantly higher than the first freezing ablation volume (14.7 ± 4.3 cm{sup 3}, p < 0.001). During the median follow-up period of 16.7 months (range, 5–52 months), LTR-free survival rates based on Kaplan–Meier analyses at 6 months, 1 year, and 2 years were 87.7%, 84.0%, and 80.2%, respectively. Only one major complication of post-procedural arterial bleeding occurred. A final ablation volume/tumor volume < 10 was a significant risk factor for LTR (p = 0.044). Conclusions: A ratio of final ablation volume to tumor volume < 10 was a significant prognostic factor for LTR. Therefore, the measurement and prediction of the final ablation volume are important to reduce LTR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a Small-Pixel Ir-TES for Optical Applications

We designed and fabricated a photon-number-resolving detector based on an iridium (Ir) transition-edge sensors (TES) with small timing jitter time for coherent optical communication. The current–voltage relationship of the small Ir-TES, with an effective area of 7 μm × 7 μm, was measured, and its electrothermal feedback operation was confirmed. This device had a transition temperature of 280 mK, which is higher than that of bulk Ir, because of the wide contact area.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the Origin of a Small Hole Pocket in the Fermi Surface of Underdoped YBa{sub 2}Cu{sub 3}O{sub y}

The comprehensive experimental studies of the quantum oscillations (QOs) in YBa{sub 2}Cu{sub 3}O{sub y} (YBCO) lead N. Doiron-Leyraud et al. (Nature Communications 6:6034, 2015) to detection of small hole pockets below the transition into the charge-ordered (CO) phase. Their interpretation of the observed energy spectrum imposes serious constraints for the possible origin of electron and hole pockets—both of them should be due to the Fermi surface (FS) reconstruction at charge ordering with biaxial order parameter. However, the results of recent X-ray experiments which reveal the uniaxial CO in the underdoped YBCO make such interpretation questionable. We show that uniaxial CO parameter in combination with preexisting electron pocket at the Γ-point of Brillouin zone suggests a plausible interpretation of QOs associated with small hole pockets in YBCO.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bifurcation and Stability Analysis of the Equilibrium States in Thermodynamic Systems in a Small Vicinity of the Equilibrium Values of Parameters

The dynamic behavior of thermodynamic system, described by one order parameter and one control parameter, in a small neighborhood of ordinary and bifurcation equilibrium values of the system parameters is studied. Using the general methods of investigating the branching (bifurcations) of solutions for nonlinear equations, we performed an exhaustive analysis of the order parameter dependences on the control parameter in a small vicinity of the equilibrium values of parameters, including the stability analysis of the equilibrium states, and the asymptotic behavior of the order parameter dependences on the control parameter (bifurcation diagrams). The peculiarities of the transition to an unstable state of the system are discussed, and the estimates of the transition time to the unstable state in the neighborhood of ordinary and bifurcation equilibrium values of parameters are given. The influence of an external field on the dynamic behavior of thermodynamic system is analyzed, and the peculiarities of the system dynamic behavior are discussed near the ordinary and bifurcation equilibrium values of parameters in the presence of external field. The dynamic process of magnetization of a ferromagnet is discussed by using the general methods of bifurcation and stability analysis presented in the paper.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Potts Model in One-Dimension on Directed Small-World Networks

The critical properties of the Potts model with q=3 and 8 states in one-dimension on directed small-world networks are investigated. This disordered system is simulated by updating it with the Monte Carlo heat bath algorithm. The Potts model on these directed small-world networks presents in fact a second-order phase transition with a new set of critical exponents for q=3 considering a rewiring probability p=0.1. For q=8 the system exhibits only a first-order phase transition independent of p.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Designing difluoro substituted benzene ring based fullerene free acceptors for small Naphthalene Di-Imide based molecules with DFT approaches

Herein current research work, we designed four new acceptor materials for small solar cell molecules with Naphthalene Di-Imide central unit by employing the wB97xd/6-31 G (d,p) and TD-wB97xd/6-31 G (d,p) level of density functional theories. Absorption properties of designed materials are excellent between the 400 nm to 510 nm with chloroform solvent and 340 nm to 490 nm in gas phase, small reorganization energy values 0.0163–0.0172 eV for electron (λ{sub e}) and 0.0205–0.0257 eV for hole transfer (λ{sub h}), large expected open circuit voltages (V{sub oc}) from 3.60 to 4.53 eV with respect to [6, 6]-phenyl-C61-butyric acid methyl ester (PCBM), high dipole moment strength ranging from 4.0199 to 8.9647 Debye in excited state and 3.3847 Debye to 7.2632 Debye in ground state which are very helpful for the further construction of organic solar cell (OSC) devices with improved and better power conversion efficiencies (PCEs).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Small-Size High-Current Generators for X-Ray Backlighting

The paper deals with the soft X-ray backlighting based on the X-pinch as a powerful tool for physical studies of fast processes. Proposed are the unique small-size pulsed power generators operating as a low-inductance capacitor bank. These pulse generators provide the X-pinch-based soft X-ray source (hν = 1–10 keV) of micron size at 2–3 ns pulse duration. The small size and weight of pulse generators allow them to be transported to any laboratory for conducting X-ray backlighting of test objects with micron space resolution and nanosecond exposure time. These generators also allow creating synchronized multi-frame radiographic complexes with frame delay variation in a broad range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗