Search NASA⌕ Search

SEARCH · Search NASA

Results for “System analysis.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

The Oncor Geodatabase for the Columbia Estuary Ecosystem Restoration Program (Annual Report, 2012)

The study reported herein was conducted by researchers at the Pacific Northwest National Laboratory (PNNL) for the U.S. Army Corps of Engineers, Portland District (Corps). The purpose of the project is to develop a geospatial, web-accessible database (called Oncor) for action effectiveness and related data from monitoring and research efforts for the Columbia Estuary Ecosystem Restoration Program (CEERP). The intent is for the Oncor database to enable synthesis and evaluation, the results of which can then be applied in subsequent CEERP decision-making. This is the first annual report in what is expected to be a 3- to 4-year project, which commenced on February 14, 2012. This report covers project activities conducted from February 2012 through February 2013. The specific objectives and tasks for the 2012 study year were as enumerated here. 1) Coordination - Coordinate with CEERP funding agencies and regional stakeholders to finalize key analysis questions and database needs for research, monitoring, and evaluation (RME) and ecosystem restoration in the lower Columbia River and estuary (LCRE) within CEERP’s adaptive management framework. 2) Database Development - Develop and demonstrate a web-based proof-of-concept geospatial database management system and analysis system for CEERP. 3) Analysis and Synthesis - Draft the CEERP 2012 Strategy Report, 2012 Action Plan, and 2013 Synthesis and Evaluation Memorandum, and provide other analytical and programmatic support. Work products for Objective 3 were reported separately.

Coleman, Andre M.↗

MATHEMATICAL FRAMEWORK FOR THE ANALYSIS OF DYNAMC STOCHASTIC SYSTEMS WITH THE RAVEN CODE

RAVEN (Reactor Analysis and Virtual control Environment) is a software code under development at Idaho National Laboratory aimed at performing probabilistic risk assessment and uncertainty quantification using RELAP-7, for which it acts also as a simulation controller. In this paper we will present the equations characterizing a dynamic stochastic system and we will then discuss the behavior of each stochastic term and how it is accounted for in the RAVEN software design. Moreover we will present preliminary results of the implementation.

97 MATHEMATICS AND COMPUTING↗

Mathematical framework for the analysis of dynamic stochastic systems with the RAVEN code

RAVEN (Reactor Analysis and Virtual control Environment) is a software code under development at Idaho National Laboratory aimed at performing probabilistic risk assessment and uncertainty quantification using RELAP-7, for which it acts also as a simulation controller. In this paper we will present the equations characterizing a dynamic stochastic system and we will then discuss the behavior of each stochastic term and how it is accounted for in the RAVEN software design. Moreover we will present preliminary results of the implementation. (authors)

97 MATHEMATICS AND COMPUTING↗

Automated regional registration and characterization of corresponding microcalcification clusters on temporal pairs of mammograms for interval change analysis

A computerized regional registration and characterization system for analysis of microcalcification clusters on serial mammograms is being developed in our laboratory. The system consists of two stages. In the first stage, based on the location of a detected cluster on the current mammogram, a regional registration procedure identifies the local area on the prior that may contain the corresponding cluster. A search program is used to detect cluster candidates within the local area. The detected cluster on the current image is then paired with the cluster candidates on the prior image to form true (TP-TP) or false (TP-FP) pairs. Automatically extracted features were used in a newly designed correspondence classifier to reduce the number of false pairs. In the second stage, a temporal classifier, based on both current and prior information, is used if a cluster has been detected on the prior image, and a current classifier, based on current information alone, is used if no prior cluster has been detected. The data set used in this study consisted of 261 serial pairs containing biopsy-proven calcification clusters. An MQSA radiologist identified the corresponding clusters on the mammograms. On the priors, the radiologist rated the subtlety of 30 clusters (out of the 261 clusters) as 9 or 10 on a scale of 1 (very obvious) to 10 (very subtle). Leave-one-case-out resampling was used for feature selection and classification in both the correspondence and malignant/benign classification schemes. The search program detected 91.2%(238/261) of the clusters on the priors with an average of 0.42 FPs/image. The correspondence classifier identified 86.6%(226/261) of the TP-TP pairs with 20 false matches (0.08 FPs/image) relative to the entire set of 261 image pairs. In the malignant/benign classification stage the temporal classifier achieved a test A{sub z} of 0.81 for the 246 pairs which contained a detection on the prior. In addition, a classifier was designed by using the clusters on the current mammograms only. It achieved a test A{sub z} of 0.72 in classifying the clusters as malignant and benign. The difference between the performance of the temporal classifier and the current classifier was statistically significant (p=0.0014). Our interval change analysis system can detect the corresponding cluster on the prior mammogram with high sensitivity, and classify them with a satisfactory accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Overall and cause‐specific mortality in the Sentinel system: A power analysis

Abstract Purpose Mortality data within the Sentinel Death Tables remain generally uncharacterized. Assessment of mortality data within Sentinel will help inform its utility for medical product safety studies. Methods To determine if Sentinel contains sufficient all‐cause and cause‐specific mortality events to power postmarketing safety studies. We calculated crude rates of all‐cause mortality and suicide and proportional mortality from suicide from 2004 to 2012 in seven Sentinel data partners. Results were stratified by data partner, sex, age group, and calendar year and compared with national estimates from Centers for Disease Control and Prevention Wide‐ranging ONline Data for Epidemiologic Research. We performed sample size estimations for all‐cause mortality and 10 leading causes of death. Results We observed 479 694 deaths, including 5811 suicides, during 68 million person‐years of follow‐up. Pooled mean death and suicide rates in the data partners were 710 and 8.6 per 100 000 person‐years, respectively (vs 810 and 11.8 nationally). The mean proportional mortality from suicide among the data partners was 1.2%, compared with 1.5% nationally. National trends of decreasing overall mortality and increasing proportional mortality for suicide were reflected within Sentinel. We estimated that detecting hazard ratios of 1.25 and 3 would require 16 442 and 460 exposed patients, respectively, for overall mortality, and 1.3 million and 37 411, respectively, for suicide. Conclusions This was the first study to investigate mortality data in the Sentinel death tables. We found that all‐cause mortality appeared well powered for use as a safety outcome and cause‐specific mortality outcomes may be adequately powered in certain circumstances. Further investigation into the quality of the Sentinel death data is needed.

Swain, Richard S.↗

Integrated System of Thermal/Dimensional Analysis for Quality Control of Metallic Melt and Ductile Iron Casting Solidification

The main objective of the present work is to introduce a specific experimental instrument and technique for simultaneously evaluating cooling curves and expansion or contraction of cast metals during solidification. Contraction/expansion analysis illustrates the solidification parameters progression, according to the molten cast iron characteristics, which are dependent on the melting procedure and applied metallurgical treatments, mold media rigidity and thermal behavior [heat transfer parameters]. The first part of the paper summarizes the performance of this two-mold device. Its function is illustrated by representative shrinkage tendency results in ductile cast iron as affected by mold rigidity (green sand and furan resin sand molds) and inoculant type (FeSi-based alloys), published in part previously. The second part of the paper illustrates an application of this equipment adapted for commercial foundry use. It conducts thermal analysis and volume change measurements in a single ceramic cup so that mold media as well as solidification conditions are constants, with cast iron quality as the variable. Experiments compared gray and ductile cast iron solidification patterns. Gray iron castings are characterized by higher undercooling at the beginning and at the end of solidification and lower graphitic expansion. Typically, ductile cast iron exhibits higher graphitic, initial expansion, conducive for shrinkage formation in soft molds.

36 MATERIALS SCIENCE↗

Timing of Chemotherapy After MammoSite Radiation Therapy System Breast Brachytherapy: Analysis of the American Society of Breast Surgeons MammoSite Breast Brachytherapy Registry Trial

Purpose: To evaluate cosmetic outcome and radiation recall in the American Society of Breast Surgeons registry trial, as a function of the interval between accelerated partial breast irradiation (APBI) and initiation of chemotherapy (CTX). Methods and Materials: A total of 1440 patients at 97 institutions participated in this trial. After lumpectomy for early-stage breast cancer, patients received APBI (34 Gy in 10 fractions) with MammoSite RTS brachytherapy. A total of 148 patients received CTX within 90 days of APBI. Cosmetic outcome was evaluated at each follow-up visit and dichotomized as excellent/good or fair/poor. Results: Chemotherapy was initiated at a mean of 3.9 weeks after the final MammoSite procedure and was administered {<=}3 weeks after APBI in 54 patients (36%) and >3 weeks after APBI in 94 patients (64%). The early and delayed groups were well balanced with respect to multiple factors that may impact on cosmetic outcome. There was a superior cosmetic outcome in those receiving chemotherapy >3 weeks after APBI (excellent/good in 72.2% at {<=}3 weeks vs. excellent/good in 93.8% at >3 weeks; p = 0.01). Radiation recall in those receiving CTX at {<=}3 weeks was 9 of 50 (18%), compared with 6 of 81(7.4%) in those receiving chemotherapy at >3 weeks (p = 0.09). Conclusion: The majority of patients receiving CTX after APBI have excellent/good cosmetic outcomes, with a low rate of radiation recall. Chemotherapy initiated >3 weeks after the final MammoSite procedure seems to be associated with a better cosmetic outcome and lower rate of radiation recall. An excellent/good cosmetic outcome in patients receiving CTX after 3 weeks was similar to the cosmetic outcome of the overall patient population who did not receive CTX.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement of ion and electron temperatures in plasma blobs by using an improved ion sensitive probe system and statistical analysis methods

We have measured ion temperature as well as electron temperature in plasma blobs observed in a linear plasma device by using an improved ion sensitive probe. Current-voltage characteristics of the ion sensitive probe inside and outside plasma blobs were re-constructed with a conditional sampling method. It is clearly found that both ion and electron temperatures in plasma blobs decrease more slowly in a cross-field direction than those in a bulk plasma without plasma blobs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗