Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Accessing new physics with an undoped, cryogenic CsI CEvNS detector for COHERENT at the SNS

We consider the potential for a 10 kg undoped cryogenic CsI detector operating at the Spallation Neutron Source to measure coherent elastic neutrino-nucleus scattering and its sensitivity to discover new physics beyond the standard model (BSM). Through a combination of increased event rate, lower threshold, and good timing resolution, such a detector would significantly improve on past measurements. We considered tests of several BSM scenarios such as neutrino nonstandard interactions and accelerator-produced dark matter. This detector’s performance was also studied for relevant questions in nuclear physics and neutrino astronomy, namely the weak charge distribution of Cs and I nuclei and detection of neutrinos from a core-collapse supernova. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Grid-based diffusion Monte Carlo for fermions without the fixed-node approximation

A diffusion Monte Carlo algorithm is introduced that can determine the correct nodal structure of the wave function of a few-fermion system and its ground-state energy without an uncontrolled bias. This is achieved by confining signed random walkers to the points of a uniform infinite spatial grid, allowing them to meet and annihilate one another to establish the nodal structure without the fixed-node approximation. An imaginary-time propagator is derived rigorously from a discretized Hamiltonian, governing a non-Gaussian, sign-flipping, branching, and mutually annihilating random walk of particles. The accuracy of the resulting stochastic representations of a fermion wave function is limited only by the grid and imaginary-time resolutions and can be improved in a controlled manner. Here, the method is tested for a series of model problems including fermions in a harmonic trap as well as the He atom in its singlet or triplet ground state. For the latter case, the energies approach from above with increasing grid resolution and converge within 0.015 E h of the exact basis-set-limit value for the grid spacing of 0.08 a.u. with a statistical uncertainty of 10 –5 E h without an importance sampling or Jastrow factor.

74 ATOMIC AND MOLECULAR PHYSICS↗

Picosecond Thermodynamics in Underdense Plasmas Measured with Thomson Scattering

The rapid evolution of electron density and temperature in a laser-produced plasma were measured using collective Thomson scattering. Unprecedented picosecond time resolution, enabled by a pulse-front-tilt compensated spectrometer, revealed a transition in the plasma-wave dynamics from an initially cold, collisional state to a quasi-stationary, collisionless state. The Thomson-scattering spectra were compared with theoretical calculations of the uctuation spectrum using either a conventional Bhatnagar Gross Krook (BGK) collision operator or the rigorous Landau collision terms: the BGK model overestimates the electron temperature by 50% in the most-collisional conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Femtosecond Compression Dynamics and Timing Jitter Suppression in a THz-driven Electron Bunch Compressor

Herein we present the first demonstration of THz driven bunch compression and timing stabilization of a relativistic electron beam. Quasi-single-cycle strong field THz radiation is used in a shorted parallel-plate structure to compress a few-fC beam with 2.5 MeV kinetic energy by a factor of 2.7, producing a 39 fs rms bunch length and a reduction in timing jitter by more than a factor of 2 to 31 fs rms. This THz driven technique offers a significant improvement to beam performance for applications like ultrafast electron diffraction, providing a critical step towards unprecedented timing resolution in ultrafast sciences, and other accelerator applications using femtosecond-scale electron beams.

43 PARTICLE ACCELERATORS↗

Angstrom-Resolved Interfacial Structure in Buried Organic-Inorganic Junctions

Charge transport processes at interfaces which are governed by complex interfacial electronic structure play a crucial role in catalytic reactions, energy storage, photovoltaics, and many biological processes. Here, the first soft X-ray second harmonic generation (SXR-SHG) interfacial spectrum of a buried interface (boron/Parylene-N) is reported. SXR-SHG shows distinct spectral features that are not observed in X-ray absorption spectra, demonstrating its extraordinary interfacial sensitivity. Comparison to electronic structure calculations indicates a boron-organic separation distance of 1.9 {\AA}, wherein changes as small as 0.1 {\AA} result in easily detectable SXR-SHG spectral shifts (ca. 100s of meV). As SXR-SHG is inherently ultrafast and sensitive to individual atomic layers, it creates the possibility to study a variety of interfacial processes, e.g. catalysis, with ultrafast time resolution and bond specificity.

74 ATOMIC AND MOLECULAR PHYSICS↗

Ultrafast Dynamics of Intrinsic Anomalous Hall Effect in the Topological Antiferromagnet Mn 3 Sn

Here, we investigate ultrafast dynamics of the anomalous Hall effect (AHE) in the topological antiferromagnet Mn 3 ⁢Sn with sub-100 fs time resolution. Optical pulse excitations largely elevate the electron temperature up to 700 K, and terahertz probe pulses clearly resolve ultrafast suppression of the AHE before demagnetization. The result is well reproduced by microscopic calculation of the intrinsic Berry-curvature mechanism while the extrinsic contribution is clearly excluded. Our work opens a new avenue for the study of nonequilibrium AHE to identify the microscopic origin by drastic control of the electron temperature by light.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quantum imaging with positronium-decay-emitted gamma rays

The use of entangled gamma rays from positronium decay for quantum-enhanced imaging of dense materials is demonstrated. Quantum ghost images, where only one of the entangled 511-keV photons interacts with the object, are obtained for tantalum samples of varying density using a 210-ps time-resolution dual detector system and a Na-22 positron source. An analysis comparing both classical and quantum imaging modalities is employed to isolate true 511-keV events from background noise. Image quality is quantitatively assessed using transmission ratios and the Michelson contrast. Quantum-correlated images are found to exhibit superior (up to approximately 1.7x, from 0.49 to 0.83 in the thickest sample measured) contrast compared to classical methods and align well with theoretical expectations. These results suggest that quantum ghost imaging with positronium-based entangled gamma rays could significantly enhance noninvasive imaging of high-density objects, with potential applications in areas such as cargo inspection and security screening.

36 MATERIALS SCIENCE↗

Optical design of the Short Pulse Soft X-ray Spectroscopy beamline at the Advanced Photon Source

The Short Pulse X-ray facility planned for the Advanced Photon Source (APS) upgrade will provide two sectors with photon beams having picosecond pulse duration. The Short Pulse Soft X-ray Spectroscopy (SPSXS) beamline will cover the 150–2000 eV energy range using an APS bending magnet. SPSXS is designed to take full advantage of this new timing capability in addition to providing circular polarized radiation. Since the correlation between time and electron momentum is in the vertical plane, the monochromator disperses in the horizontal plane. The beamline is designed to maximize flux and preserve the time resolution by minimizing the number of optical components. The optical design allows the pulse duration to be varied from 1.5 to 100 ps full width at half-maximum (FWHM) without affecting the energy resolution, and the resolution to be changed with minimal effect on the pulse duration. More than 10 9 photons s -1 will reach the sample with a resolving power of 2000 and a pulse duration of ~2 ps for photon energies between 150 and 1750 eV. The spot size expected at the sample position will vary with pulse duration and exit slit opening. At 900 eV and at a resolving power of 2000 the spot will be ~10 µm × 10 µm with a pulse duration of 2.3 ps FWHM.

47 OTHER INSTRUMENTATION↗

Submillisecond X-ray photon correlation spectroscopy from a pixel array detector with fast dual gating and no readout dead-time

Small-angle scattering X-ray photon correlation spectroscopy (XPCS) studies were performed using a novel photon-counting pixel array detector with dual counters for each pixel. Each counter can be read out independently from the other to ensure there is no readout dead-time between the neighboring frames. A maximum frame rate of 11.8 kHz was achieved. Results on test samples show good agreement with simple diffusion. Lastly, the potential of extending the time resolution of XPCS beyond the limit set by the detector frame rate using dual counters is also discussed.

43 PARTICLE ACCELERATORS↗

Laser, vacuum and gas reaction chamber for operando measurements at NSLS-II's 28-ID-2

We present a laser reaction chamber that we have developed for in situ/operando X-ray diffraction measurements at the NSLS-II 28-ID-2 X-ray powder diffraction beamline. This chamber allows for rapid and dynamic sample heating under specialized gas environments, spanning ambient conditions down to vacuum pressures. We demonstrate the capabilities of this setup through two applications: laser-driven heating in polycrystalline iron oxide and in single-crystal WTe 2 . Our measurements reveal the ability to resolve chemical reaction kinetics over minutes with 1 s time resolution. This setup advances opportunities for in situ/operando X-ray diffraction studies of both bulk and single-crystal materials.

36 MATERIALS SCIENCE↗

Inverter Model Validation and Calibration Using Phasor Measurement Unit Data

As the penetration of inverter-based renewable energy resources increases in the power grid, especially at the distribution and microgrid levels, the need to accurately represent them in planning studies increases as well. However, due to the lack of well-established standard procedures, and vendor reluctance towards the detailed sharing of proprietary models, automated dynamic model validation and parameter calibration tools for inverter based resources (IBRs) remain scarce. This work presents a model validation and parameter calibration platform for representing IBRs with generic phasor-domain models. Phasor measurements of power system events are used for continuous validation using the data playback method, and model parameters are re-calibrated if a significant mismatch between measurements and model response is observed. Unique features of the proposed platform include- (a) an iterative Bayesian optimization approach towards parameter calibration to address a possible mismatch between the structures of generic models implemented in simulation softwares and actual commercial inverters, (b) error metrics designed to account for a possible mismatch between the time resolution of simulation and measurements, and (c) analysis of the measurement-simulation mismatch to provide guidance to engineering personnel regarding model shortcomings. The performance of the platform has been illustrated using both simulated data and field measurements to validate/calibrate inverter models in GridLAB-D.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Passive Inter-Photon Imaging

Digital camera pixels measure image intensities by converting incident light energy into an analog electrical current, and then digitizing it into a fixed-width binary representation. This direct measurement method, while conceptually simple, suffers from limited dynamic range and poor performance under extreme illumination --- electronic noise dominates under low illumination, and pixel full-well capacity results in saturation under bright illumination. We propose a novel intensity cue based on measuring inter-photon timing, defined as the time delay between detection of successive photons. Based on the statistics of inter-photon times measured by a time-resolved single-photon sensor, we develop theory and algorithms for a scene brightness estimator which works over extreme dynamic range; we experimentally demonstrate imaging scenes with a dynamic range of over ten million to one. The proposed techniques, aided by the emergence of single-photon sensors such as single-photon avalanche diodes (SPADs) with picosecond timing resolution, will have implications for a wide range of imaging applications: robotics, consumer photography, astronomy, microscopy and biomedical imaging.

97 MATHEMATICS AND COMPUTING↗

Analysis and Modeling of the End-to-End I/O Performance on OLCF's Titan Supercomputer

With the increase of scale and complexity seen in a variety of leadership-class scientific computation and simulation applications, it has become more important to understand their I/O performance characteristics. The user-observed performance is a combination of properties of how the application is using the HPC facility, as well as how others' use of the facility causes variability in the static machine capabilities. Our work leverages statistical analysis of I/O performance data gathered with fine time resolution over a full week from Titan supercomputer. Based on observed properties of the distribution of I/O latencies, we build a three-state hidden Markov model (HMM) to characterize the end-to-end I/O performance on Titan. We parameterize our model using part of the field-gathered I/O performance data and validate it against the rest. The validation results demonstrate that our model can capture the dynamics of end-to-end I/O performance on Titan accurately.

Wan, Lipeng↗

Picosecond Synchronization System for Quantum Networks

The operation of long-distance quantum networks requires photons to be synchronized and must account for length variations of quantum channels. We demonstrate a 200 MHz clock-rate fiber optic-based telecommunication C-band quantum network using off-the-shelf components combined with custom-made electronics. The network is backed by a scalable and fully automated synchronization system with ps-scale timing resolution. Synchronization of the photons is achieved by distributing O-band-wavelength laser pulses between network nodes. Specifically, we distribute photon pairs between three nodes, and measure a reduction of coincidence-to-accidental ratio from 77 to only 42 when the synchronization system is enabled, which permits high-fidelity qubit transmission. Our demonstration sheds light on the role of noise in quantum communication and represents a key step in realizing deployed co-existing classical-quantum networks.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of Timing Properties of SiPMs at Fermilab

We continue our timing measurements of Silicon Photomultipliers (SiPM) at the picosecond level at Fermilab .. We using SiPMs readout based on Ortec system, also as on fast waveform digitizer DRS4 [1]. SiPM's signal pulse shape was investigated. The single photoelectron time resolution (SPTR) was measured for the signals coming from the SiPM's. Dependence of the SPTR on the SiPms size was measured. Results of the last test beam test with SiPMs are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Estimation Matrix Calibration of PMU Data-driven State Estimation Using Neural Network

Linear state estimation (LSE) is a phasor measurement unit (PMU) data-based power system state estimation that incorporates a linear measurement model in rectangular coordinates. Due to the high computational efficiency and high observational time-resolution, LSE can act as a supplementary state estimation in a wide-area monitoring system (WAMS). The performance of LSE is relatively sensitive to noises in measurements. Therefore, the estimation accuracy relies heavily on the accuracy of the estimation matrix, which is directly influenced by the measurement weight matrix. This paper proposes two novel calibration method of the estimation matrix using neural networks. One is based on the minimum absolute network loss (ANL), and the other is based on the minimum average squared network loss (ASNL). Both methods are tested and compared with LSE algorithms on the IEEE 14-bus system

neural network↗

Time-stamping and counting of single photons using fast camera

I will discuss fast optical cameras based on the back-illuminated silicon sensor and Timepix3 ASIC. The sensor has high quantum efficiency, and the chip provides nanosecond scale time resolution and data-driven readout with 80Mpix/sec bandwidth. The intensified version of the camera is single photon sensitive and since recently has been used for registration of single photons in a variety of quantum information science and quantum imaging experiments as well as for other applications. We briefly review the camera and describe recent experiments with a Hong-Ou-Mandel interferometer to characterize its photon counting capabilities.

79 ASTRONOMY AND ASTROPHYSICS↗